Instruction/ maintenance manual of the product SURTD3000XLI-BNDL APC
Go to page of 22
Inst alla tion and Operation Smart-UPS™ RT Uniterr uptible Pow er Supp ly SUR TD3 00 0/5000 XL 200-2 40 V AC T ower /Ra ck -M ount 3U.
This manual and the safet y guide are available in Englis h on the enc losed CD and the APC W eb site, www .apc.com. 您可以从随附的 CD 与 APC 网站 (www. apc.com)上获得本手册与安全指南的中文版本。 您可以從隨附的 CD 與 APC 網站 (www.
1 Sma rt- UPS TM RT Uninterruptible Power Supply SUR TD 3000/5000 VA 200-240 VAC Tower/Rack-Mount 3U Engl ish 2 010 AP C by S c hn ei der E l ectr i c. APC , t h e APC l o go, S ma rt -UP S a nd P o werC hu t e a r e o wn ed by S chn ei d er El ect ri c Indu stries S.
2 I ntr oduct ion Th e APC TM by Sch n eid er El ect ri c Smar t- UPS TM RT i s a h igh-p er form an ce, un int err upt i ble power supply (UPS) that p r ov ides prote ction f or elec tr o n ic equi pm e nt f rom ut i lity powe r blacko uts, b row n o uts , s ags a nd s urge s.
3 Wir ing and C onne ctin g the U PS 5000 VA XLI MO DE LS O NLY : H ARDWI RI NG I NS TRUCTIO NS • Wir in g mu st be per for m ed by a q ual ifi ed el ectr i cian . • Ins tal l a h ig h mag n e tic 30 /32 A u ti lity circ ui t b reake r . • Adh ere t o all na tion al and l ocal el ectr ical cod es.
4 C ONN ECTING THE B AT TE RY MOD UL ES AN D A TTACH I NG THE F RONT B EZE L .
5 B ASIC C ON N ECT ORS serial com Th e ser ial conn ect or i s to be used for in ter faci ng with A PC Power Ch ute soft war e an d termin al emula ti on soft war e. Use only cable s approved by APC. An y o ther inte rfac e cab l e wil l be inco mp atib le w ith th e U PS co nn ector .
6 C ONN ECTING E Q UIP M E NT AN D P O WER TO THE UPS 1. Co nn e c t e quip ment to t h e U PS (c able s not includ e d f or XL J/X LT/XL TW mo dels ).
7 O PERA TION Load S M ART -UPS RT F RONT D ISPLAY Ba tte ry C ha rge In d ic at or De sc r i pt ion On line Th e On lin e L ED illu mi nate s w he n t h e U PS is d raw ing u tility pow e r a nd p e rfo r m i ng doub le conve r sio n t o supp l y power to co n n ec ted e quipme n t.
8 Feature Functio n Col d Start Whe n t here is no u tility pow er a nd the U PS is o ff , pres s and hold the b utto n to po wer u p th e UPS an d conn ect ed equ i pm e nt . The U PS w ill e mi t tw o be eps . Du ring t h e se co n d b ee p, r ele ase the b utton .
9 U SER C ON FIGU R A BLE I TE M S N OTE : S ETT ING S ARE MADE T HRO UG H SUPPL IED P OW ER C HUTE SOFTW ARE , OPTI ONA L S MART S LOT AC C ESSOR Y C ARD S , OR T ER MINAL M OD E .
10 N OTE : S ETT ING S ARE MADE T HRO UG H SUPPL IED P OW ER C HUTE SOFTW ARE , OPTI ONA L S MART S LOT AC C ESSOR Y C ARD S , OR T ER MINAL M OD E . F UNCTION F ACT O RY D EFAUL T U SER S ELECT ABL E.
11 C ONN ECTING THE EPO (E M ERGEN CY P OWER O FF ) O PTION Th e out pu t power can be di sabl ed in an em erg en cy by cl osi ng a swit ch con n ected t o the EP O.
12 T ERM INAL M ODE TO C ONFIGURE UPS P ARAMETERS 3000 VA m o dels: Terminal M o de is a menu d rive n i n te r face th at e nables c o nfi guratio n o f the U PS by users not w i shing to us e Po w erChute ® soft wa r e or an op t i ona l Net wor k M ana ge m en t Ca r d .
13 5000 V A m odel s: Ter mi nal Mo de is a me nu d riv e n i n te r f ace t h a t e nab le s c onf igurat io n of the U PS by use r s n o t us i ng Po we r C hu te s of t w ar e o r t he inst al le d Ne tw o r k Ma nage me nt Ca rd i nterf ace s. Conn ect th e ser ial ca ble t o th e ser ial p ort o n the ba ck of th e UPS.
14 • Pre ss 2 and EN TER to c ha nge the B atte r y Settin gs. • Typ e in the n umber of ext ern al batt er y p ack s ( four bat ter y mod ul es per pack ), an d pr ess ENTE R . (Numbe r of pa cks : 1 = 1 SU RT192XLBP , 2 = 2 SU RT192XLB P etc.) • Pr ess 3 and E NTE R t o a ccept th e chan ges.
15 M A I N T ENANCE A ND T RAN SPORT Replaci ng the Ba ttery Mod ule Th i s U P S h a s an ea sy to r epl a ce, h ot- swapp a ble bat t er y modu l e. Rep la cem ent is a sa fe pr ocedu r e, is ola ted fr om elect ri ca l haz ard s. You ma y leave th e UPS a nd conn ect ed equ i pm e n t on d urin g th e pr oced ur e.
16 R EPLACI NG B ATTERY M ODULES X Y Z [ ] ^ _ Disconnec ting the Bat tery for Transpor t Always DI SCONN ECT T HE BA TTER Y(s) b efore s hippi ng in co mp liance with U.S. Department o f Transp ortatio n (DO T) and I ATA r egu latio ns. The batt ery(s) m ay remain i n the UP S.
17 T ROUBLESHOOT IN G , S ER VIC E , A ND W ARR ANT Y I NF O R M A T IO N U s e the table b elow to s olve mino r i ns ta lla tio n a nd o pera tio n pro b lems. R efe r to the APC W eb site, ww w.ap c .c o m for a ssi stan ce with comp lex UPS p r oblem s.
18 P ROBLE M AND P OSSI BL E C AU S E S OLU TI ON BY PASS LED ILLUMIN ATES The bypass swi t ch has be en turne d on m anuall y or thro ugh an acc esso ry.
19 Ser vice If th e U PS r eq ui res se r v ic e do n o t retu rn it to t h e de ale r. Fo llow thes e s teps : 1. Re vi e w th e pr obl em s d i sc us se d i n th e Troublesh ooting se ctio n o f this manu al to el im ina te com m on pr obl em s. 2. If the p roble m persists, co nta ct APC Custo m er S uppo r t t hrou gh the APC Web sit e, www.
20 R AD I O F REQUE N CY W AR N I NG S T his equ i p ment ha s b een t e sted a nd fo un d t o co m ply wit h th e li mit s fo r a Cl a ss A di gi ta l de vi ce, pu r sua nt t o par t 1 5 o f t h e FC C Rul es.
An important point after buying a device APC SURTD3000XLI-BNDL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought APC SURTD3000XLI-BNDL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data APC SURTD3000XLI-BNDL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, APC SURTD3000XLI-BNDL you will learn all the available features of the product, as well as information on its operation. The information that you get APC SURTD3000XLI-BNDL will certainly help you make a decision on the purchase.
If you already are a holder of APC SURTD3000XLI-BNDL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime APC SURTD3000XLI-BNDL.
However, one of the most important roles played by the user manual is to help in solving problems with APC SURTD3000XLI-BNDL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device APC SURTD3000XLI-BNDL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center