EN
LevelOne logo
Official user manual

LevelOne GSW-2490TXM

57 pages·1.1 MB·Network Router·PDF·ENDEFRITNLJA
LevelOne GSW-2490TXM
Table of Contents 78 sections LevelOne · GSW-2490TXM 24-Port + 2 Slide-in Slots SNMP Switch · 1. Introduction · Package Contents · … ShowHide
LevelOnep.1GSW-2490TXM 24-Port + 2 Slide-in Slots SNMP Switchp.11. Introductionp.1Package Contentsp.3GSW-2490TXMp.4Management Methodsp.4Console and Telnet Managementp.4SNMP Network Managementp.42. Hardware Descriptionp.5Hardware Descriptionp.5LED Indicatorsp.6Rear Panelp.7Diagnostic Testp.73. Connecting to the Networkp.8Pre-Installation Requirementsp.8cannot be restricted. Mounting the Switchp.9Desktop Mountingp.9Rack-mounted Installationp.10Connecting to the Switchp.11Login in the Console Interfacep.12Main Menup.131. System Informationp.132. Management Setupp.142.1. Network Configurationp.142.2. Serial Port Configurationp.152.4. Trap Receiverp.162.5. Management Capability Setupp.162.6. Trap Filter Setupp.173. Device Control Menup.183.1. Switch Device Configurationp.183.2. Switch Port Configurationp.193.3. Permanent Address Configurationp.193.3.2. Static Multicast Address Configurationp.203.4. Port Statisticsp.203.5. Spanning Tree Protocol Configurationp.213.7. Post-Based VLAN Configurationp.223.8. 802.1Q VLAN Configurationp.233.8.1. 802.1Q VLAN Configurationp.233.8.2. Dynamic VLAN Tablep.243.8.3. VLAN Untagged Configurationp.253.8.4 GARP Configurationp.253.9. MTU/MDU Per-Port VLAN Tablep.263.10. IGMP Snooping Tablep.273.11. Trunk Group Configurationp.273.12. Port Mirroring Configurationp.284. User Authenticationp.295. System Utilityp.305.1 System Restartp.305.2 Factory Resetp.305.4 System Downloadp.314. Web-Based Managementp.31About Web-based Managementp.32System Loginp.32System Informationp.33Network Configurationp.33Serial Port Configurationp.34SNMP Community Setupp.34Trap Receiverp.35Management Capability Setupp.36Trap Filter Setupp.36Switch Port Configurationp.38Permanent Address Configurationp.39Spanning Tree Protocol Configurationp.41Spanning Tree Protocol Port Configurationp.42Port Statisticsp.43VLAN Configurationp.43IGMP Configurationp.46User Authenticationp.47System Utility System Restartp.48Factory Resetp.48System Downloadp.49Update Settingp.495. Network Configurationp.50Collapsed Backbone Applicationp.51Departmental Bridgep.52High Performance Switched Workgroupp.53Figure 5-3: High Performance Switched Workgroup Application IEEE 802.1Q VLAN Applicationp.546. Product Specificationsp.56
Page 1 of the LevelOne GSW-2490TXM user manual — LevelOne
Page 1 · click to enlarge
Page 1

LevelOne

GSW-2490TXM 24-Port + 2 Slide-in Slots SNMP Switch

1. Introduction

Welcome to the World of Switching-Network. In modern society, communication and information sharing are fundamental to our lifestyle. Computer networks are one of the fastest means of communication. As your company grows, your network demands will increase. …

Page 2 of the LevelOne GSW-2490TXM user manual — LevelOne
Page 2 · click to enlarge
Page 2

The LevelOne GSW-2490TXM SNMP Switch are designed to provide your network with Ethernet, Fast Ethernet, Gigabit Ethernet connectivity over twisted pair and fiber optic cabling. Two expansion slots on the front panel of the LevelOne GSW-2490TXM SNMP Switches further add to the flexibility of the systems.

LevelOne GSW-2490TXM — LevelOne diagram (page 2)
Fig. 1 · LevelOne

Figure 1-1. The 24TP+2Exp-Slot Switch

The LevelOne GSW-2490TXM SNMP is a managed Fast Ethernet switch, that provides a number of exceptional features with extremely flexible configuration expansions without compromising the wire speed performance. The LevelOne GSW-2490TXM SNMP switch provide wire-speed switching with advanced bridging functions like VLAN, priority, multicast filtering, link aggregation and port mirroring. It can also support two different GBIC type as Mini GBIC LC and standard GBIC SC. Many comprehensive network management functions are provided, such as Spanning Tree protocol for loop prevention and full recovery, VLAN configuration and IGMP snooping for multicast grouping configuration. VT100 console, remote telnet login, SNMP, and Web Interfaces are all standard management features. Features

_ Conforms to IEEE802.3,IEEE802.3u,IEEE802.3z ,IEEE802.3x

IEEE802.1p, IEEE802.3ac, IEEE802.1D, IEEE802.1Q 24 auto-sensing 10/100Mbps Ethernet RJ-45 ports 2 Expansion slots for optional modules: 1-port Duplex SC

Gigabit ( SX/LX ), 100Mbps Fiber ( SC/MT-RJ/VF-45 ),

1 RJ-45 for UTP or STP Gigabit 1000T Module with Automatic MDI/MDIX support, Mini GBIC LC type and Standard GBIC SC type. One Console-connecting port for communication parameter

configuration Auto-negotiation & Full-duplex/half-duplex supported Store-and- Forward error free packet forwarding scheme 9.6 GB Backplane Bandwidth 8K-entry MAC address table 6Mbits share memory Full wire speed forwarding rate

Page 3 of the LevelOne GSW-2490TXM user manual — Package Contents
Page 3 · click to enlarge
Page 3

LED-indicators for Power, per port Link/Active, FDX/COL

10/100M Gigabit Module LK/ACT, FDX/ COL statuses

Console and Telnet Configuration Web-based management SNMP network management IEEE 802.1Q Tagging VLAN and Port Based VLAN

supported IEEE802.3x Flow Control Mechanism is used in Full-Duplex

mode and back-pressure is used in half-duplex IEEE 802.1D Blocking, Learning, and Forwarding state are

supported for Spanning Tree Protocol IEEE 802.3ac Extends the maximum Ethernet Length to

1522 to Add the 4-Byte VLAN Tag IEEE802.1p, provides four levels priority per port, packets

are prioritized according to the source port or the 802.1p priority tag Security Functions Supported IGMP Snooping and GMRP protocol supported Link Aggregation function supported Port Priority - 802.1p & TOS (Type of Service ) supported TFTP support for firmware on network upgrade Port Mirror supported

Package Contents

Unpack the carton of the LevelOne GSW-2490TXM SNMP Switch and verify them against the checklist below.

LevelOne GSW-2490TXM — Package Contents diagram (page 3)
Fig. 2 · Package Contents

LevelOne GSW-2490TXM SNMP Switch Rubber Feet

Intelligent Management Features

Page 4 of the LevelOne GSW-2490TXM user manual — SNMP Network Management
Page 4 · click to enlarge
Page 4
LevelOne GSW-2490TXM — GSW-2490TXM diagram (page 4)
Fig. 3

24-Port + 2 Slide-in Slot SNMP Switch Rack-mounted Kit RS-232 cable User Guide

GSW-2490TXM

LevelOne GSW-2490TXM — GSW-2490TXM diagram (page 4)
Fig. 4

Figure 1-2. Package Contents

Compare the contents of your LevelOne GSW-2490TXM SNMP Switch package with the standard checklist above. If any item is missing or damaged, please contact your local dealer for service.

Management Methods

The LevelOne GSW-2490TXM SNMP Switch supports following management methods:

Console and Telnet Management Web-based Management SNMP Network Management

Console and Telnet Management

Console Management is done through the RS-232 Console Port. Managing the LevelOne GSW-2490TXM SNMP Switch in this method requires a direct connection between PC and the LevelOne GSW-2490TXM SNMP Switch. While Telnet management is done over the network. Once the LevelOne GSW-2490TXM SNMP Switch is on the network, you can use Telnet to Log in and change the configuration.

SNMP Network Management

SNMP (Simple Network Management Protocol) provides a means to monitor and control network device, and to manage configurations, statistic collection, performance, and security. Data is passed from SNMP agents, which are hardware & software

Power Cord

Page 5 of the LevelOne GSW-2490TXM user manual — Hardware Description
Page 5 · click to enlarge
Page 5

processes reporting activity in each network device to the workstation console used to oversee the network. The agent return information contained in a MIB (Management Information Base), which is a data structure that defines what is obtainable from the device and what can be controlled.

2. Hardware Description

This section mainly describes the hardware of the LevelOne GSW- 2490TXM SNMP Switch, and gives a functional overview of the Switch.

The physical dimensions of the LevelOne GSW-2490TXM SNMP Switch are: 440mmx 225mmx 44.5mm ( Lx Wx H )

Hardware Description

The LevelOne GSW-2490TXM SNMP Switch is a fixed 24-port auto-sensing Ethernet RJ-45 connectors, and its chassis contains two expansion slots. The optional modules come with the built-in CPU module. The Front Panel

The Front Panel of the LevelOne GSW-2490TXM SNMP Switch consists of 24x auto-sensing 10/100Mbps Ethernet RJ-45 Ports, two optional expansion slots, and Console port. The LED Indicators are also located on the front panel of the Switch.

LevelOne GSW-2490TXM — Hardware Description diagram (page 5)
Fig. 5 · Hardware Description

Figure 2-1. The Front Panel of LevelOne GSW-2490TXM SNMP Switch

Expansion Slots for Optional Module

10/100Base-TX RJ-45 ports ( Auto MDI/MDIX ): 24x 10/100Mbps auto-sensing port for 10Base-T or 100Base-TX devices connection. Note: [ MDI/MDIX means that you can connect

RJ-45 Ports · LED Indicators · Console Port

Page 6 of the LevelOne GSW-2490TXM user manual — LED Indicators
Page 6 · click to enlarge
Page 6

to another Switch or workstation without changing non-crossover or crossover cabling. ]

Expansion Slots : For two of the following Optional modules : 1 Port Gigabit 1000Base-T Intelligent Switch Modules, 1 Port Gigabit 1000Base-SX/LX Intelligent Fiber Modules. 1 Port 100Base-FX Intelligent Fiber Module

Console Port : Console Management can be done through the Console Port. It requires a direct connection between the LevelOne GSW-2490TXM SNMP Switch and an end station ( PC ) via a RS-232 cable.

LED Indicators

LevelOne GSW-2490TXM — LED Indicators diagram (page 6)
Fig. 6 · LED Indicators

Figure 2-2 The LED Indicators

All LED indicators are located on the front panel of the LevelOne GSW-2490TXM SNMP Switch. They provide a real-time indication of system and operational status. The following table gives descriptions of the LED status and their meanings.

LevelOne GSW-2490TXM — LED Indicators diagram (page 6)
Fig. 7 · LED Indicators
LEDStatusDescription PWRGreenPower On OffPower is Off. 100GreenThe port is operating at the speed of 100Mbps. OffNo device attached or in 10Mbps mode
Page 7 of the LevelOne GSW-2490TXM user manual — Diagnostic Test
Page 7 · click to enlarge
Page 7
LK/ACTGreenThe port is connecting with the device. BlinksThe port is receiving or transmitting data. OffNo device attached. FD/COLYellowThe port is operating in Full-duplex mode. BlinksCollision of Packets occurs in the port. OffNo device attached or in half-duplex mode .
LevelOne GSW-2490TXM — Rear Panel diagram (page 7)
Fig. 8 · Rear Panel

Table 2-1. The Descriptions of LED Indicators

Rear Panel

The 3-pronged power plug, On/off Switch are located at the Rear Panel of the LevelOne GSW-2490TXM SNMP Switch. ( The Ventilation fan is located on the side of the Switch ). The Switch will work with AC in the range 100-240V AC, 50-60Hz.

LevelOne GSW-2490TXM — Rear Panel diagram (page 7)
Fig. 9 · Rear Panel

Figure 2-3. The Rear Panel of the LevelOne GSW-2490TXM SNMP Switch Power On

After all network cables are connected, plug the power cord into the power socket on the back panel and the other end into a power outlet. Turn the power On using the power Switch on the back panel.

Check the front panel Power indicator to see if power is properly supplied. The Switch uses a universal power supply that requires no additional adjustment.

Diagnostic Test

After the installation is completed and AC power is applied to the Switch, the system will automatically perform a diagnostic test. When the Power LED is on within 5 seconds, the Diagnostic status

Page 8 of the LevelOne GSW-2490TXM user manual — Pre-Installation Requirements
Page 8 · click to enlarge
Page 8

LEDs will soon flash red.

When the Switch passes the self-test within 15 seconds, the Link /ACT LED turns on.

3. Connecting to the Network

This section provides the installation procedure and instructions for assigning IP address.

Pre-Installation Requirements

Before you start hardware installation, make sure your installation environment has below items:

PCs with 10/100Mbps Ethernet NICs/ 100Mbps Fiber NICs:

Your PC must have a standard Ethernet interface to connect to the Switch. UTP cable with RJ45 connectors/ Fiber cable with MT-RJ/

VF-45 connectors: Check if the cable and connectors work properly. A power outlet: 100 to 240V AC at 50 to 60 Hz: Make sure

that the Switch power is accessible and cables can be connected easily.

Page 9 of the LevelOne GSW-2490TXM user manual — Desktop Mounting
Page 9 · click to enlarge
Page 9
Dedicated power supplyUse dedicated power circuits or

power conditioners to supply reliable electrical power to the network devices. A dry cool place: Keep the Switch away from moisture. Avoid

direct sunlight, heat source, and high amount of electromagnetic interference around. Mounting tools: If you intend to mount the Switch on a rack,

make sure you have all the tools, mounting brackets, screws etc. Caution: Cabling must be away from sources of electrical noise such as

radio, computers, transmitters, broadband amplifiers, power lines and keep away from TVs, hair dryers, and microwave. Air flow around the Switch and through its vents on the rear

cannot be restricted. Mounting the Switch

The LevelOne GSW-2490TXM SNMP Switch is suitable for use in an office environment where it can be rack-mounted in standard EIA 19-inch racks or standalone.

Desktop Mounting

1. Set the Switch on a sufficiently large flat space with a power outlet nearby, and about the center of all networked devices. 2. Make sure mounting surface on the bottom of the Switch is grease dust free. 3. Remove adhesive backing from your Rubber Feet.
LevelOne GSW-2490TXM — Desktop Mounting diagram (page 9)
Fig. 10 · Desktop Mounting

Figure 3-1. Attaching Rubber Feet to each corner

on the bottom of the Switch

4. Apply the Rubber Feet to each corner on the bottom of the Switch. These footpads can prevent the Switch from shock/vibrations.
Page 10 of the LevelOne GSW-2490TXM user manual — Rack-mounted Installation
Page 10 · click to enlarge
Page 10

Rack-mounted Installation

The LevelOne GSW-2490TXM SNMP Switch come with a rack- mounted kid and can be mounted in an EIA standard size, 19-inch Rack. The Switch can be placed in a wiring closet with other equipment.

Perform the following steps to rack mount the Switch:

A. Position one bracket to align with the holes on one side of the

Switch and secure it with the smaller bracket screws. Then attach the remaining bracket to the other side of the Switch.

LevelOne GSW-2490TXM — Rack-mounted Installation diagram (page 10)
Fig. 11 · Rack-mounted Installation

Figure 3-2. Attach mounting brackets with screws

B. After attached both mounting brackets, position the LevelOne

GSW-2490TXM SNMP Switch ( UTP/MT-RJ/VF-45 ) Switch in the rack by lining up the holes in the brackets with the appropriate holes on the rack. Secure the Switch to the rack with a screwdriver and the rack-mounting screws.

Page 11 of the LevelOne GSW-2490TXM user manual — Connecting to the Switch
Page 11 · click to enlarge
Page 11
LevelOne GSW-2490TXM — Connecting to the Switch diagram (page 11)
Fig. 12 · Connecting to the Switch

Figure 3-3. Mount the 24TP+1Fiber Module Switch in an EIA

Connecting to the Switch

The Console port is a male DB-9 connector that enables a connection to a PC or terminal for monitoring and configuring the LevelOne GSW-2490TXM SNMP Switch. Use the supplied RS-232 cable with a female DB-9 connector to connect a terminal or PC to the Console port.

The Console configuration ( out of band ) allow you to set your Switch to enable a user at a remote console terminal to communicate with the LevelOne GSW-2490TXM SNMP Switch as if the console terminal were directly connected to it.

standard 19-inch Rack

Page 12 of the LevelOne GSW-2490TXM user manual — Login in the Console Interface
Page 12 · click to enlarge
Page 12
LevelOne GSW-2490TXM — Login in the Console Interface diagram (page 12)
Fig. 13 · Login in the Console Interface

Figure 3-4. Connecting the LevelOne GSW-2490TXM SNMP Switch

to a terminal via RS-232 cable

Login in the Console Interface

When the connection between Switch and PC is finished, turn on the PC and run a terminal emulation program or Hyper Terminal and configure its communication parameters to match the following default characteristics of the console port:

Baud Rate9600 bps Data Bits: 8 Parity: none Stop Bit: 1 Control flow: None
LevelOne GSW-2490TXM — Login in the Console Interface diagram (page 12)
Fig. 14 · Login in the Console Interface

Figure 3-5. The settings of communication parameters

Page 13 of the LevelOne GSW-2490TXM user manual — 1. System Information
Page 13 · click to enlarge
Page 13
LevelOne GSW-2490TXM — Main Menu diagram (page 13)
Fig. 15 · Main Menu

After you have finished parameter settings, click “OK“. When the screen shows above, press “admin“ Key for the User name, then the Main Menu of console management appears.

Main Menu

LevelOne GSW-2490TXM — Main Menu diagram (page 13)
Fig. 16 · Main Menu

Figure 3-6. The screen of Main Menu

After login you will see the main menu screen as illustrated in the picture. The main menu displays all the sub-menu and pages that are available in the console interface.

1. System Information

Page 14 of the LevelOne GSW-2490TXM user manual — 2.1. Network Configuration
Page 14 · click to enlarge
Page 14
LevelOne GSW-2490TXM — 2. Management Setup diagram (page 14)
Fig. 17 · 2. Management Setup

Figure 3-7. The System Information Menu

The system information screen displays information such as hardware, software versions, and system up time. You can also enter specific information about you and your organization here.

2. Management Setup

LevelOne GSW-2490TXM — 2. Management Setup diagram (page 14)
Fig. 18 · 2. Management Setup

Figure 3-8. The Management Setup Menu

The management setup menu contains 6 submenus and are discussed in the section in the following pages.

2.1. Network Configuration

Page 15 of the LevelOne GSW-2490TXM user manual — 2.2. Serial Port Configuration
Page 15 · click to enlarge
Page 15
LevelOne GSW-2490TXM — 2.2. Serial Port Configuration diagram (page 15)
Fig. 19 · 2.2. Serial Port Configuration

Figure 3-9. The Network Configuration Men

This screen is provided to change the IP setting of your switch according to your network configuration. After changing the setting you need to save it so that whatever changes you made can take effect. Also note that the value under Current column will not reflect the changes you made until next time you login after resetting the switch.

2.2. Serial Port Configuration

LevelOne GSW-2490TXM — 2.2. Serial Port Configuration diagram (page 15)
Fig. 20 · 2.2. Serial Port Configuration

Figure 3-10. The Serial Port Configuration

You can change the serial port setting through this screen to suit you environment, however, we recommend you to keep the default setting. 2.3. SNMP Community Setup

Page 16 of the LevelOne GSW-2490TXM user manual — 2.5. Management Capability Setup
Page 16 · click to enlarge
Page 16
LevelOne GSW-2490TXM — 2.4. Trap Receiver diagram (page 16)
Fig. 21 · 2.4. Trap Receiver

Figure3-11. The SNMP Community Menu

In the SNMP Community Menu, you can create different communities and customize their access right. Use key to move the highlight bar and select desired community to modify or add a new community (use space bar to toggle the access right and status)

2.4. Trap Receiver

LevelOne GSW-2490TXM — 2.4. Trap Receiver diagram (page 16)
Fig. 22 · 2.4. Trap Receiver

Figure 3-12. The Trap Receiver Menu

Use trap receiver screen to designate certain community to receive trap(s) generated by the system.

2.5. Management Capability Setup

Page 17 of the LevelOne GSW-2490TXM user manual — 2.6. Trap Filter Setup
Page 17 · click to enlarge
Page 17
LevelOne GSW-2490TXM — 2.6. Trap Filter Setup diagram (page 17)
Fig. 23 · 2.6. Trap Filter Setup

Figure 3-13. The Management Capability setup Menu

This is where you can enable / disable Web-Based management capability which in turn allow or disallow the access to management function through the use of a web browser such as Microsoft IE.

2.6. Trap Filter Setup

LevelOne GSW-2490TXM — 2.6. Trap Filter Setup diagram (page 17)
Fig. 24 · 2.6. Trap Filter Setup

Figure 3-14. The Trap Filter Setup menu

The system can generate a set of SNMP traps upon the occurrence of those events. By checking a filter event, you are turning off the filter and enabling the trap associated with that event.

Page 18 of the LevelOne GSW-2490TXM user manual — 3.1. Switch Device Configuration
Page 18 · click to enlarge
Page 18

3. Device Control Menu

LevelOne GSW-2490TXM — 3. Device Control Menu diagram (page 18)
Fig. 25 · 3. Device Control Menu

Figure 3-15. The Device Control menu

Device control menu contains 15 submenus where you get to maneuver most of the functions and features.

3.1. Switch Device Configuration

LevelOne GSW-2490TXM — 3.1. Switch Device Configuration diagram (page 18)
Fig. 26 · 3.1. Switch Device Configuration

Figure 3-16. The Switch Device Configuration menu

Use key to toggle the Enable / Disable field and type in appropriate value in the Time and Priority field.

  • Broadcast Storm Prevention can be set to 6% 0r 20% beside Disable. The percentage indicates the allowance against the capacity. When its disable there will be no limitation on the incoming rate of broadcast / multicast traffic, otherwise limitation on those traffics will be set to the percentage accordingly.
  • When QoS is enabled you can map the Type of Service of your
Page 19 of the LevelOne GSW-2490TXM user manual — 3.3. Permanent Address Configuration
Page 19 · click to enlarge
Page 19

choice (according to IEEE 802.1p) to the four priority levels provided. •There are three different mode of VLAN supported in this system – 802.1Q, Port Base VLAN, MTU/MDU. The choice you made here will ultimately decide the VLAN mode and function for entire system (the configuration of the other two VLAN mode will have no effect to the system behavior).

3.2. Switch Port Configuration

LevelOne GSW-2490TXM — 3.2. Switch Port Configuration diagram (page 19)
Fig. 27 · 3.2. Switch Port Configuration

Figure 3-17. The Switch Port Configuration menu

  • The Ports (24+2) of the system are divided and displayed in three separated pages. Use PREV PAGE, NEXT PAGE to list desired port range and select the port with navigation key. In the port configuration screen (display in next page) you can configure the common characteristics such as speed negotiation, flow control, and VLAN ID as well as the following special features provided with the system:
  • Per-Port Priority – Four levels of priority (High, Medium, Low and Lowest) can be set to each individual port. However, the priority level set through QoS / Type of Service configuration in the device configuration menu will have higher precedence.
  • Local IP Forwarding – A policy instrument that provides a way for local IP traffic to cross the local VLAN boundary set force in a typical (secure) access environment.
  • Bandwidth provisioning - 8 levels of speed control facilitate the provisioning control for access provider.

3.3. Permanent Address Configuration

Page 20 of the LevelOne GSW-2490TXM user manual — 3.4. Port Statistics
Page 20 · click to enlarge
Page 20
LevelOne GSW-2490TXM — 3.3.2. Static Multicast Address Configuration diagram (page 20)
Fig. 28 · 3.3.2. Static Multicast Address Configuration

Figure 3-18. The Permanent Address Configuration menu

There are 128 static unicast groups and 32 multicast supported by the system. Two submenus contains in this section.

3.3.1. Static Unicast Address Configuration You can creat, modify, or delete Static Unicast Address by selecting entries from the following screen.

  • Enter the MAC address of a system you wish to set as static unicast address the port associated with the system. Use<Space Bar> to toggle the status field between Disable, Forwarding, FilterIn, and Filter-Out.
  • Disable – This Unicast Address entry has no effect to the switch system.
  • Forwarding – All packets designated to this MAC address will be forward (and only to) the designated port.
  • Filter-in – Only packets originated to from this MAC address will be permitted to enter this port, in other words, packets originated from other MAC address will be dropped at this port automatically.
  • Filter-out – All packets designated to this MAC address will be blocked (the port is disregard here).

3.3.2. Static Multicast Address Configuration

In the Static Multicast Configuration Menu screen, besides the MAC Address and Status field (Enable/Disable), you add member(s) to the group by checking the port(s) with key.

3.4. Port Statistics

Page 21 of the LevelOne GSW-2490TXM user manual — 3.5. Spanning Tree Protocol Configuration
Page 21 · click to enlarge
Page 21
LevelOne GSW-2490TXM — 3.5. Spanning Tree Protocol Configuration diagram (page 21)
Fig. 29 · 3.5. Spanning Tree Protocol Configuration

Figure 3-19. The Port Statistics menu

You can view the statistics information display in this screen regarding a certain port by entering the port number in the port id field. You can also refresh or reset the counter as you wish.

3.5. Spanning Tree Protocol Configuration

LevelOne GSW-2490TXM — 3.5. Spanning Tree Protocol Configuration diagram (page 21)
Fig. 30 · 3.5. Spanning Tree Protocol Configuration

Figure 3-20. The Spanning Tree Protocol Configuration menu

You can alter the Spanning Tree status with key. If you enable the spanning tree protocol, you must complete the Priority and Time fields with appropriate value. Also note that you

Page 22 of the LevelOne GSW-2490TXM user manual — 3.7. Post-Based VLAN Configuration
Page 22 · click to enlarge
Page 22

can choose to leave a menu screen without applying any changes you had made at any time by pressing key and then confirm with key.

3.6. Spanning Tree Protocol Port Configuration

LevelOne GSW-2490TXM — 3.7. Post-Based VLAN Configuration diagram (page 22)
Fig. 31 · 3.7. Post-Based VLAN Configuration

Figure 3-21. The Spanning Tree Protocol port Configuration menu

In this screen you can assign spanning priority and path cost to any port(s). A port with higher priority, lower path cost is less likely to be blocked if Spanning Tree Protocol is detecting network loop.

3.7. Post-Based VLAN Configuration

LevelOne GSW-2490TXM — 3.7. Post-Based VLAN Configuration diagram (page 22)
Fig. 32 · 3.7. Post-Based VLAN Configuration

Figure 3-22. The Port Based VLAN Configuration menu

Assigning physical ports within workgroup is simple, and is a common method of defining a virtual workgroup – VLAN. It delivers the benefit of broadcast control and simplifies configuration for the network manager.

Page 23 of the LevelOne GSW-2490TXM user manual — 3.8.1. 802.1Q VLAN Configuration
Page 23 · click to enlarge
Page 23

One advantage of the Port-Based VLAN is its simplicity and easy to configure, however, limited security is its drawback – anyone can plug into the port and gain access to the VLAN.

LevelOne GSW-2490TXM — 3.8. 802.1Q VLAN Configuration diagram (page 23)
Fig. 33 · 3.8. 802.1Q VLAN Configuration

Select the VLAN entry to create, modifies, or deletes the VLAN group. Use to check (join) port(s) to the VLAN group.

3.8. 802.1Q VLAN Configuration

Only as 802.1Q VLAN mode was chosen then the settings of the following submenus would be meaningful and therefore need to be configured carefully.

3.8.1. 802.1Q VLAN Configuration

This screen shows the currently set VLAN sorted by index number. Select the entry to create, modify, or delete and proceed to the next screen.

Page 24 of the LevelOne GSW-2490TXM user manual — 3.8.2. Dynamic VLAN Table
Page 24 · click to enlarge
Page 24
LevelOne GSW-2490TXM — 3.8.2. Dynamic VLAN Table diagram (page 24)
Fig. 34 · 3.8.2. Dynamic VLAN Table

Figure 3-23. The Port Based VLAN Configuration menu

LevelOne GSW-2490TXM — 3.8.2. Dynamic VLAN Table diagram (page 24)
Fig. 35 · 3.8.2. Dynamic VLAN Table

( ) – Port(s) is not set as static (fixed) member of the VLAN but it can become a member through Dynamic VLAN Registration. (F) – Port(s) is set as static (fixed) member of the VLAN and can be registered as a dynamic VLAN member as well. (B) – Port(s) is being forbidden to be neither a static member nor a dynamic member of the VLAN.

3.8.2. Dynamic VLAN Table

Page 25 of the LevelOne GSW-2490TXM user manual — 3.8.4 GARP Configuration
Page 25 · click to enlarge
Page 25
LevelOne GSW-2490TXM — 3.8.3. VLAN Untagged Configuration diagram (page 25)
Fig. 36 · 3.8.3. VLAN Untagged Configuration

Figure 3-24. The Dynamic VLAN Table menu

This screen displays the VLAN mapping for port(s) that join the VLAN(s) through Dynamic VLAN Registration.

3.8.3. VLAN Untagged Configuration

LevelOne GSW-2490TXM — 3.8.3. VLAN Untagged Configuration diagram (page 25)
Fig. 37 · 3.8.3. VLAN Untagged Configuration

Figure 3-25. The Port Untag Configuration menu

All ports are set by default as in this switch system, to change port(s) to just use to uncheck - ( ) the port(s) from the Port Map.

3.8.4 GARP Configuration

Page 26 of the LevelOne GSW-2490TXM user manual — 3.9. MTU/MDU Per-Port VLAN Table
Page 26 · click to enlarge
Page 26
LevelOne GSW-2490TXM — 3.9. MTU/MDU Per-Port VLAN Table diagram (page 26)
Fig. 38 · 3.9. MTU/MDU Per-Port VLAN Table

Figure 3-26. The GARP Configuration menu

GARP (Generic Attribute Registration Protocol) defines the architecture, rules of operation, state machines and variables for the registration and de-registration of attribute values. It allows dynamic filter entries for VLAN membership to be distributed among the Forwarding Databases of VLAN-aware switches. By joining GVRP (GARP VLAN Registration Protocol), it helps maintaining VLAN information. The rule of the aging scheme is: GARP Leave All Time > GARP Leave Time > GARP Join Time

3.9. MTU/MDU Per-Port VLAN Table

LevelOne GSW-2490TXM — 3.9. MTU/MDU Per-Port VLAN Table diagram (page 26)
Fig. 39 · 3.9. MTU/MDU Per-Port VLAN Table

Figure 3-27. The MTU/MDU Per-Port VLAN Table menu

This screen only reflects the setting you made in Switch Device Configuration menu - there is no change can be made here. Should you set the VLAN Mode to mode and

Page 27 of the LevelOne GSW-2490TXM user manual — 3.11. Trunk Group Configuration
Page 27 · click to enlarge
Page 27

port then port 1 ~ 25 will be mapped to port 26 - the uplink port, otherwise, port 1 ~ 12 and port 13 ~ 24 will be mapped to uplink port 25 and port 26 accordingly.

3.10. IGMP Snooping Table

LevelOne GSW-2490TXM — 3.10. IGMP Snooping Table diagram (page 27)
Fig. 40 · 3.10. IGMP Snooping Table

Figure 3-28. The IGMP Snooping Table

By supporting IGMP (Internet Group Management Protocol) Snooping, the switch can forward multicast traffic intelligently. Packets are forwarded to the ports that belong to the multicast group instead of being broadcast to all ports and possibly disrupting network performance. This lookup table reflects the multicast group(s) (up to 32) configuration of your system and provides an overview of the port(s) map to each multicast group.

3.11. Trunk Group Configuration

Page 28 of the LevelOne GSW-2490TXM user manual — 3.12. Port Mirroring Configuration
Page 28 · click to enlarge
Page 28
LevelOne GSW-2490TXM — 3.12. Port Mirroring Configuration diagram (page 28)
Fig. 41 · 3.12. Port Mirroring Configuration

Figure 3-29. The Trunk Configuration Menu

Multiple links between switches can be grouped (trunk) to work as one virtual, aggregate link. You can create 4 trunks at a time; each trunk can hold up to 8 ports - only ports of the same speed can belong to a single trunk.

3.12. Port Mirroring Configuration

LevelOne GSW-2490TXM — 3.12. Port Mirroring Configuration diagram (page 28)
Fig. 42 · 3.12. Port Mirroring Configuration

Figure 3-30. The Port Mirroring Configuration Menu

By enabling port mirroring, traffic to and from the source port will be forwarded to the target port. You can select any of the 26 port as either the Source port or the Target port by using to scroll though the desired port number.

Page 29 of the LevelOne GSW-2490TXM user manual — 4. User Authentication
Page 29 · click to enlarge
Page 29

4. User Authentication

LevelOne GSW-2490TXM — 4. User Authentication diagram (page 29)
Fig. 43 · 4. User Authentication

Figure 3-31. The User Authentication Menu

You can change the password setting as in the user authentication menu. You can also create user and assign different privilege to suit your needs.

LevelOne GSW-2490TXM — 4. User Authentication diagram (page 29)
Fig. 44 · 4. User Authentication

After selecting an entry to add or modify, type in user name and password, toggle the user privilege with and then update the changes.

Page 30 of the LevelOne GSW-2490TXM user manual — 5.2 Factory Reset
Page 30 · click to enlarge
Page 30

5. System Utility

5.1 System Restart

LevelOne GSW-2490TXM — 5. System Utility diagram (page 30)
Fig. 45 · 5. System Utility

Figure 3-32. The System Restart Menu

As mention earlier, you need to perform either a or to have the changes you made written into the NVRAM so that changes are really saved and keep in effect until you make change to them again.

5.2 Factory Reset

LevelOne GSW-2490TXM — 5.2 Factory Reset diagram (page 30)
Fig. 46 · 5.2 Factory Reset

Figure 3-33. The Factory Reset Menu

The system can let you to reset all configurations as you wish anytime. 5.3 Login Timeout Interval

Page 31 of the LevelOne GSW-2490TXM user manual — 4. Web-Based Management
Page 31 · click to enlarge
Page 31
LevelOne GSW-2490TXM — 5.4 System Download diagram (page 31)
Fig. 47 · 5.4 System Download

Figure 3-34. The Login Timeout Interval

You can set up the time you need for the automatic log-out in anytime.

5.4 System Download

LevelOne GSW-2490TXM — 5.4 System Download diagram (page 31)
Fig. 48 · 5.4 System Download

Figure 3-35. The System Download Menu

Use TFTP download the code you need, and two code as Boot code and System Software code for upgrading.

4. Web-Based Management

Page 32 of the LevelOne GSW-2490TXM user manual — System Login
Page 32 · click to enlarge
Page 32

This section introduces the configuration and functions of the Web- Based management.

About Web-based Management

Inside the CPU board of the switch exists an embedded HTML web site residing in flash memory. It offers advanced management features and allow users to manage the switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer.

The Web-Based Management supports Internet Explorer 5.0. It is based on Java Applets with an aim to reduce network bandwidth consumption, enhance access speed and present an easy viewing screen.

System Login

1. Start Internet Explorer. 2. Type http:// and the IP address of the Modular Switch ( for example, the default is 192.168.16.1 ) in the Location or Address field. Press Enter.
LevelOne GSW-2490TXM — System Login diagram (page 32)
Fig. 49 · System Login

Figure 4-1: The Password Window 3. The Password screen appears. 4. Type user name and password. The default is “ admin ” for both. 5. Press “Enter” or Click ”OK”, then the Home Screen of the Web- based management appear.

Page 33 of the LevelOne GSW-2490TXM user manual — Network Configuration
Page 33 · click to enlarge
Page 33

System Information

LevelOne GSW-2490TXM — System Information diagram (page 33)
Fig. 50 · System Information

24-Port with 2 Slide-in Slots SNMP Switch

Figure 4-2 The System Information Menu S

You can manage the Switch using third-party’s SNMP ( Simple Network Management Protocol ) agent. Access rights to the SNMP agent are controlled by community strings. To set system name, system location and system contact, you can type the desired text string in the corresponding edit box. Management Setup

Network Configuration

LevelOne GSW-2490TXM — Network Configuration diagram (page 33)
Fig. 51 · Network Configuration

Figure 4-3. The Network Configuration Menu

You can change the IP address, subnet mask and default gateway of the managed node. (You can also do that from RS232 console). Enter the IP address, subnet mask and default gateway in the corresponding edit box.

If you want to change the user name or password for the managed node, the following steps is needed:

Page 34 of the LevelOne GSW-2490TXM user manual — SNMP Community Setup
Page 34 · click to enlarge
Page 34

Click the "Change Password" checkbox

Enter the user name in "Username" edit box

Enter the same password in "Password" and "Confirm

Press the "Apply" button

You should reboot system to let your settings take effect if you have changed one of the IP address, subnet mask and default gateway.

Serial Port Configuration

LevelOne GSW-2490TXM — Serial Port Configuration diagram (page 34)
Fig. 52 · Serial Port Configuration

Figure 4-4. The Serial Port Configuration Menu

You can change the serial port setting through this screen to suit you environment, however, using the default setting is recommended.

SNMP Community Setup

Password" edit box

Page 35 of the LevelOne GSW-2490TXM user manual — Trap Receiver
Page 35 · click to enlarge
Page 35
LevelOne GSW-2490TXM — Trap Receiver diagram (page 35)
Fig. 53 · Trap Receiver

Figure 4-5. The SNMP Community Setup Menu

Public Community ( Read-only access right ) means that member of community can view the information but can not make changes to the configuration.

Private Community ( Read/Write access right ) allow the member of the community to view and make change to the configuration.

To set the "Public" and "Private" community name, you can type the desired text string in the corresponding edit box.

Trap Receiver

LevelOne GSW-2490TXM — Trap Receiver diagram (page 35)
Fig. 54 · Trap Receiver

Figure 4-6. The Trap Receiver Menu

Use trap receiver screen to designate certain community to receive trap(s) generated by the system.

Page 36 of the LevelOne GSW-2490TXM user manual — Trap Filter Setup
Page 36 · click to enlarge
Page 36

Management Capability Setup

LevelOne GSW-2490TXM — Management Capability Setup diagram (page 36)
Fig. 55 · Management Capability Setup

Figure 4-7. The Management Capability Setup Menu

This is where you can enable / disable Web-Based management capability which in turn allow or disallow the access to management function through the use of a web browser such as Microsoft IE.

Trap Filter Setup

LevelOne GSW-2490TXM — Trap Filter Setup diagram (page 36)
Fig. 56 · Trap Filter Setup

Figure 4-8. The Trap Filter Setup Menu

Page 37 of the LevelOne GSW-2490TXM user manual — Management Capability Setup
Page 37 · click to enlarge
Page 37

The system can generate a set of SNMP traps upon the occurrence of those events. By checking a filter event, you are turning off the filter and enabling the trap associated with that event. Device Control Switch Configuration

LevelOne GSW-2490TXM — Management Capability Setup diagram (page 37)
Fig. 57 · Management Capability Setup

Figure 4-9. The Switch Configuration upper Menu

1. There are three different mode of VLAN supported in this system – 802.1Q, Port Base VLAN, MTU/MDU. The choice you made here will ultimately decide the VLAN mode and function for entire system (the configuration of the other two VLAN mode will have no effect to the system behavior). 2. Broadcast Storm Prevention can be set to 6% 0r 20% beside Disable. The percentage indicates the allowance against the capacity. When its disable there will be no limitation on the incoming rate of broadcast / multicast traffic, otherwise limitation on those traffics will be set to the percentage accordingly. 3. When QoS is enabled you can map the Type of Service of your choice (according to IEEE 802.1p) to the four priority levels provided.

LevelOne GSW-2490TXM — Management Capability Setup diagram (page 37)
Fig. 58 · Management Capability Setup

Figure 4-10. The Switch Configuration lower Menu

Page 38 of the LevelOne GSW-2490TXM user manual — Switch Port Configuration
Page 38 · click to enlarge
Page 38

Switch Port Configuration

LevelOne GSW-2490TXM — Switch Port Configuration diagram (page 38)
Fig. 59 · Switch Port Configuration

Figure 4-11. The Port Administration in Switch Port Configuration Menu

The Ports (24+2) of the system are divided and displayed in three separated pages. In the port Administration menu, select a port that you can configure the common characteristics such as speed negotiation, flow control, and VLAN ID as well as the following special features provided with the system:

  • Per-Port Priority – Four levels of priority (High, Medium, Low and Lowest) can be set to each individual port. However, the priority level set through QoS / Type of Service configuration in the device configuration menu will have higher precedence.
  • Local IP Forwarding – A policy instrument that provides a way for local IP traffic to cross the local VLAN boundary set force in a typical (secure) access environment.
  • Bandwidth provisioning - 8 levels of speed control facilitate the provisioning control for access provider.
LevelOne GSW-2490TXM — Switch Port Configuration diagram (page 38)
Fig. 60 · Switch Port Configuration
Page 39 of the LevelOne GSW-2490TXM user manual — Permanent Address Configuration
Page 39 · click to enlarge
Page 39

Figure 4-12. The Trunk Group in Switch Port Configuration Menu

Port trunking is the ability to group several ports to increase the bandwidth between this switch and another compatible switch. This is an inexpensive way to increase bandwidth. We define port trunking as the ability to group set of ports (up to 4 groups).

LevelOne GSW-2490TXM — Permanent Address Configuration diagram (page 39)
Fig. 61 · Permanent Address Configuration

Figure 4-13. The Port Mirror in Switch Port Configuration Menu

Port Mirror is to mirror traffic (all frames) from a specific resource port to a target port. This help tracking down network errors or erroneous packet transfers without interrupting the flow of data across the network.

If you want to monitor all receive and transmit packets of one port. You can do the following:

Choose the monitored port in " Source Port "

Choose the corresponding target module, port in “Target Port" choice box.

Click the corresponding "Enabled" check box.

Press "Submit" button

Permanent Address Configuration

Page 40 of the LevelOne GSW-2490TXM user manual — Permanent Address Configuration
Page 40 · click to enlarge
Page 40
LevelOne GSW-2490TXM — Permanent Address Configuration diagram (page 40)
Fig. 62 · Permanent Address Configuration

Figure 4-14. The Static Unicast Address in Permanent Address Configuration Menu

You can Add, modify, or delete Static Unicast Address by selecting entries from the following screen.

  • Enter the MAC address of a system you wish to set as static unicast address the port associated with the system. Select the status field between Disable, Forwarding, Filter-In, and Filter-Out.
  • Disable – This Unicast Address entry has no effect to the switch system.
  • Forwarding – All packets designated to this MAC address will be forward (and only to) the designated port.
  • Filter-in – Only packets originated to from this MAC address will be permitted to enter this port, in other words, packets originated from other MAC address will be dropped at this port automatically.
  • Filter-out – All packets designated to this MAC address will be blocked (the port is disregard here).
LevelOne GSW-2490TXM — Permanent Address Configuration diagram (page 40)
Fig. 63 · Permanent Address Configuration
Page 41 of the LevelOne GSW-2490TXM user manual — Spanning Tree Protocol Configuration
Page 41 · click to enlarge
Page 41

Figure 4-15. The Static Multicast Address Configuration in Permanent Address Configuration Menu

In the Static Multicast Configuration Menu screen, you can add member(s) to the group by checking the port(s).

Spanning Tree Protocol Configuration

Spanning tree is a link management protocol that provides path redundancy while preventing undesirable loops in the network. For Layer 2 Ethernet network to function properly, only one active path must exist between two stations.

The spanning-tree algorithm calculates the best loop-free path throughout a switched network. STP forces redundant data paths into a standby (blocked) state. If a network segment in the spanning tree fails and a redundant path exists, the spanning-tree algorithm recalculates the spanning tree topology and activates the standby path.

LevelOne GSW-2490TXM — Spanning Tree Protocol Configuration diagram (page 41)
Fig. 64 · Spanning Tree Protocol Configuration

Figure 4-16. The Spanning Tree Protocol Configuration upper Menu

If you enable the spanning tree protocol, you must complete the Priority and Time fields with appropriate value.

Page 42 of the LevelOne GSW-2490TXM user manual — Spanning Tree Protocol Port Configuration
Page 42 · click to enlarge
Page 42
LevelOne GSW-2490TXM — Spanning Tree Protocol Port Configuration diagram (page 42)
Fig. 65 · Spanning Tree Protocol Port Configuration

Figure 4-17. The Spanning Tree Protocol Configuration lower Menu

Spanning Tree Protocol Port Configuration

LevelOne GSW-2490TXM — Spanning Tree Protocol Port Configuration diagram (page 42)
Fig. 66 · Spanning Tree Protocol Port Configuration

Figure 4-18. The Spanning Tree Protocol Port Configuration upper

In this upper and lower menu, you can assign spanning priority and path cost to any port(s). A port with higher priority, lower path cost is less likely\to be blocked if Spanning Tree Protocol is detecting network loop.

Menu

Page 43 of the LevelOne GSW-2490TXM user manual — VLAN Configuration
Page 43 · click to enlarge
Page 43
LevelOne GSW-2490TXM — Port Statistics diagram (page 43)
Fig. 67 · Port Statistics

Figure 4-19. The Spanning Tree Protocol Port Configuration lower Menu

Port Statistics

LevelOne GSW-2490TXM — Port Statistics diagram (page 43)
Fig. 68 · Port Statistics

Figure 4-20. The Port Statistics Menu

You can view the statistics information display in this screen regarding a certain port by entering the port number in the port id field. You can also refresh or reset the counter as you wish.

VLAN Configuration

Page 44 of the LevelOne GSW-2490TXM user manual — Port Statistics
Page 44 · click to enlarge
Page 44
LevelOne GSW-2490TXM — Port Statistics diagram (page 44)
Fig. 69 · Port Statistics

Figure 4-21. The Static VLAN Configuration Menu

(S) – Port(s) is set as static (fixed) member of the VLAN. (D) – Port(s) is set as static (fixed) member of the VLAN and can be registered as a dynamic VLAN member as well. (C) – Port(s) is being both a static member and a dynamic member of the VLAN.

LevelOne GSW-2490TXM — Port Statistics diagram (page 44)
Fig. 70 · Port Statistics

Figure 4-22. The Dynamic VLAN Table Menu

This screen displays the VLAN mapping for port(s) that join the VLAN(s) through Dynamic VLAN Registration.

Page 45 of the LevelOne GSW-2490TXM user manual — Port Statistics
Page 45 · click to enlarge
Page 45
LevelOne GSW-2490TXM — Port Statistics diagram (page 45)
Fig. 71 · Port Statistics

Figure 4-23. The Untagged Configuration Menu

All ports are set by default as Untagged in this switch system, to change port(s) to Tagged just pick the port number you need and select “No” from the Port Map.

LevelOne GSW-2490TXM — Port Statistics diagram (page 45)
Fig. 72 · Port Statistics

Figure 4-24. The MTU/MDU Per Port VLAN Table in The VLAN Configuration Menu

This screen as above only reflects the setting you made in Switch Device Configuration menu - there is no change can be made here. Should you set the VLAN Mode to mode and port then port 1 ~ 25 will be mapped to port 26 - the uplink port, otherwise, port 1 ~ 12 and port 13 ~ 24 will be mapped to uplink port 25 and port 26 accordingly.

Page 46 of the LevelOne GSW-2490TXM user manual — IGMP Configuration
Page 46 · click to enlarge
Page 46
LevelOne GSW-2490TXM — IGMP Configuration diagram (page 46)
Fig. 73 · IGMP Configuration

Figure 4-25. The Port Based VLAN Configuration in The VLAN Configuration Menu

Select the VLAN entry to create, modifies, or deletes the VLAN group. Choose the port(s) to the VLAN group GARP Configuration

LevelOne GSW-2490TXM — IGMP Configuration diagram (page 46)
Fig. 74 · IGMP Configuration

Figure 4-26. The GARP Configuration Menu

GARP (Generic Attribute Registration Protocol) defines the architecture, rules of operation, state machines and variables for the registration and de-registration of attribute values. It allows dynamic filter entries for VLAN membership to be distributed among the Forwarding Databases of VLAN-aware switches. By joining GVRP (GARP VLAN Registration Protocol), it helps maintaining VLAN information. The rule of the aging scheme is: GARP Leave All Time > GARP Leave Time > GARP Join Time

IGMP Configuration

Page 47 of the LevelOne GSW-2490TXM user manual — User Authentication
Page 47 · click to enlarge
Page 47
LevelOne GSW-2490TXM — User Authentication diagram (page 47)
Fig. 75 · User Authentication

Figure 4-27. The IGMP Configuration Menu

Multicasting is used to support real-time applications such as video conferencing or streaming audio. IGMP (Internet Group Multicast Protocol) allows you to query for any attached hosts who want to receive a specific multicast service. The switch looks up the IP Multicast Group used for this service and adds any port, which received a similar request to that group. It then propagates the service request on to any neighboring multicast switch to ensure that it will continue to receive the multicast service. By supporting IGMP (Internet Group Management Protocol) Snooping, the switch can forward multicast traffic intelligently. Packets are forwarded to the ports that belong to the multicast group instead of being broadcast to all ports and possibly disrupting network performance. This lookup table reflects the multicast group(s) (up to 32) configuration of your system and provides an overview of the port(s) map to each multicast group.

User Authentication

LevelOne GSW-2490TXM — User Authentication diagram (page 47)
Fig. 76 · User Authentication

Figure 4-28. The User Authentication Menu

Page 48 of the LevelOne GSW-2490TXM user manual — Factory Reset
Page 48 · click to enlarge
Page 48

You can change the password setting as in the user authentication menu. You can also create user and assign different privilege to suit your needs. After selecting an entry to add or modify, type in user name and password, toggle the user privilege and then update the changes

System Utility System Restart

LevelOne GSW-2490TXM — System Utility System Restart diagram (page 48)
Fig. 77 · System Utility System Restart

Figure 4-29. The System Restart Menu

As mention earlier, you need to perform either a Cold Start or Warm Star to have the changes you made so that changes are really saved and keep in effect until you make change to them again.

Factory Reset

LevelOne GSW-2490TXM — Factory Reset diagram (page 48)
Fig. 78 · Factory Reset

Figure 4-30. The Factory Reset Menu

Page 49 of the LevelOne GSW-2490TXM user manual — Update Setting
Page 49 · click to enlarge
Page 49

All selections in this menu are separate to be setup their own default. Login Timeout Interval

LevelOne GSW-2490TXM — System Download diagram (page 49)
Fig. 79 · System Download

Figure 4-31. The Login Timeout Interval Menu

You can set up the time you need for the automatic log-out in anytime.

System Download

LevelOne GSW-2490TXM — System Download diagram (page 49)
Fig. 80 · System Download

Figure 4-31. The System Download Menu

Use TFTP download the code you need, and two code as Boot code and System Software code for upgrading.

Update Setting

Page 50 of the LevelOne GSW-2490TXM user manual — 5. Network Configuration
Page 50 · click to enlarge
Page 50
LevelOne GSW-2490TXM — 5. Network Configuration diagram (page 50)
Fig. 81 · 5. Network Configuration

Figure 4-32. The Update Setting Menu

You can save current settings by click the "Submit" checkbox .You should reboot the system so that your current settings will take effect.

5. Network Configuration

This section provides you a few samples of network topology in which LevelOne GSW-2490TXM SNMP Switch ( UTP/MT-RJ/VF- 45, Intelligent ) is used.

Page 51 of the LevelOne GSW-2490TXM user manual — Collapsed Backbone Application
Page 51 · click to enlarge
Page 51

The Switch provides versatile configuration options for the network. It is ideally suited as a workgroup or segment Switch in a network; it has the flexibility to provide Switched 10Mbps to the desktop or shared hubs, aggregate traffic from workgroup Switches, or provide dedicated 100Mbps or 1000Mbps ( Gigabit ) to servers with bandwidth-intensive applications. And because all Fast Ethernet ports auto-negotiate for operation at 100 Mbps the Switch is perfectly suited to an evolving network environment where demand for network speed is increasing.

Collapsed Backbone Application

For small network where rapid growth can be expected in the near future, this Switch is an ideal solution supporting backbone connectivity.

The Switch can be used as a standalone Switch for a group of heavy traffic users. Switching is brought to the desktop either through a single end-station per Switch port or through a multi-port Switch. A 1000 Mbps server is connected to the Switch, providing end stations high-speed accessibility to its applications. This configuration provides dedicated 100 Mbps connections to the network center, to the server, and up to 40 users ( while 2 Optional 8-port module are installed ).

When the network needs expansion, you can simply connect the Switch to any IEEE 802.3 ( Ethernet ), IEEE 802.3u ( Fast Ethernet ) and 802.3ab ( Gigabit Ethernet ) compliant Switch utilizing the Auto MDI/MDIX function. This Switch can also cooperate with a wide range of networking devices (e.g., firewall routers and printer servers) added to the network.

Page 52 of the LevelOne GSW-2490TXM user manual — Departmental Bridge
Page 52 · click to enlarge
Page 52
LevelOne GSW-2490TXM — Departmental Bridge diagram (page 52)
Fig. 82 · Departmental Bridge

Figure 5-1. Collapsed Backbone Application

Departmental Bridge

For enterprise networks where large data broadcasts are constantly processed, this Switch is an ideal solution for department users to connect to the corporate backbone. The LevelOne GSW-2490TXM SNMP Switch used as segment Switch can alleviate user contention for bandwidth and eliminate server and network bottlenecks. All ports can connect to high-speed department servers that need high bandwidth. This Switch provides parallel communications within it’s Gigabit port, which can run up to 2000 Mbps at Full-duplex.

The Switch makes key servers available to more users by allowing multiple conversations to occur concurrently, thereby significantly expanding overall network throughput. Moreover, this Switch eases supervision and maintenance by allowing network manager centralize multiple servers in a single location.

Page 53 of the LevelOne GSW-2490TXM user manual — High Performance Switched Workgroup
Page 53 · click to enlarge
Page 53
LevelOne GSW-2490TXM — High Performance Switched Workgroup diagram (page 53)
Fig. 83 · High Performance Switched Workgroup
Figure 5-2Departmental Bridge Application

High Performance Switched Workgroup

This Switch is also a good solution for connecting two workgroups, supporting the throughput, for example, of 800Mbps. This application is useful for power groups that need high bandwidth.

The most common LAN implementations use a combination of standard switches, bridges and routers. The bridges and routers quickly become bottlenecks, reducing overall network throughput. Switching to higher-speed LANs such as FDDI or ATM is not a good choice for most people. However, such broadband equipment is still extremely expensive and hard to maintain. Besides, you have to replace all existing Ethernet cable and adapter cards, restructure your network, and

Page 54 of the LevelOne GSW-2490TXM user manual — Figure 5-3: High Performance Switched Workgroup Application IEEE 802.1Q VLAN Application
Page 54 · click to enlarge
Page 54

implement more expensive administration procedures.

The Switch can provide the same bandwidth of FDDI and ATM at much lower costs. In addition, all current adapters and network devices can still be used. The Switching cross-domain connection is better than bridge and router because users can retain LAN structure in which any node can freely communicate with any other node.

LevelOne GSW-2490TXM — Figure 5-3: High Performance Switched Workgroup Application IEEE 802.1Q VLAN Application diagram (page 54)
Fig. 84 · Figure 5-3: High Performance Switched Workgroup Appl…

Figure 5-3: High Performance Switched Workgroup Application IEEE 802.1Q VLAN Application

The Switch supports up to 128 Group, IEEE 802.1Q-compatible virtual LAN ( VLANs ).

You can group the Switch ports into broadcast domains by assigning them to the same VLAN to increase network capacity and performance. With network segmentation, each Switch port connects to a segment that is a single broadcast domain. Packets received in one VLAN can only be forwarded within that VLAN.

VLAN allows the grouping of end stations logically, based not on physical location but on business policies such as job function or department. Members of a group can be dispersed throughout a facility - they do not have to be connected in close physical locations.

Hence, group members can coordinate their data communication requirements regardless of the actual working locations; and the logical network can extend to any point you want it to. Moreover,

Port-based VLAN Workgroup

Page 55 of the LevelOne GSW-2490TXM user manual — Figure 5-3: High Performance Switched Workgroup Application IEEE 802.1Q VLAN Application
Page 55 · click to enlarge
Page 55

VLAN groups can be modified at any time to add, move or change users without any re-cabling.

LevelOne GSW-2490TXM — Figure 5-3: High Performance Switched Workgroup Application IEEE 802.1Q VLAN Application diagram (page 55)
Fig. 85 · Figure 5-3: High Performance Switched Workgroup Appl…
Figure 5-4VLAN Workgroup Application Shared Server

The Switch compliant to the IEEE802.1Q tagging VLAN standard allows ports to exist in multiple VLANs for shared resources, such as servers, printers, and Switch-to-Switch connections. It is also possible to have resources exist in multiple VLANs on one Switch as shown in the following figure.

LevelOne GSW-2490TXM — Figure 5-3: High Performance Switched Workgroup Application IEEE 802.1Q VLAN Application diagram (page 55)
Fig. 86 · Figure 5-3: High Performance Switched Workgroup Appl…
Figure 5-5Shared Server

In this example, stations on different VLANs share resources. As a result, VLAN 1 and VLAN 2 can access VLAN 3 for printing. The broadcasts from ports configured in VLAN3 can be seen by all

Page 56 of the LevelOne GSW-2490TXM user manual — 6. Product Specifications
Page 56 · click to enlarge
Page 56

VLAN port members of VLAN3.

6. Product Specifications

This section provides the specifications of LevelOne GSW- 2490TXM SNMP Switch, and the following table lists them.

Standards Compliance IEEE802.3 10BASE-T

IEEE802.3u 100BASE-TX and 100BASE-FX IEEE802.3ab 1000BASE-T IEEE802.3z 1000BASE-SX IEEE802.3x Flow Control IEEE802.1p Priority Support IEEE802.3ac Frame Extension for VLAN Tagging IEEE802.1D spanning tree IEEE802.1Q VLAN tagging Protocol CSMA/CD Media connector 100M FX, SC, MTRJ, VF45 Basic unit: 24 RJ-45 for STP or UTP, Auto MDI/MDI-X Support Gigabit SX/LX Module: 1 Duplex SC Gigabit 1000T Module: 1 RJ-45 for UTP or STP, Auto MDI/MDI-X Support GBIC: Mini GBIC LC type, Standard GBIC SC type Transfer Rate 14880 Packets per second for 10Mbps 148800 packets per second for 100Mbps 1488000 packets per second for 1000Mbps Backplane Bandwidth 9.6Gb Switch Technology Store-and-Forward Error Free Packet Forwarding Scheme Supports Hardware Level Broadcast Storm Prevention without Consuming System CPU Utilization

Page 57 of the LevelOne GSW-2490TXM user manual — 6. Product Specifications
Page 57 · click to enlarge
Page 57

MAC Address 8K MAC address with auto learning function Data Buffer 6Mb share memory LED System Power, per port Link/active, FDX/Col,10/100Mbps Gigabit Module Link/active, FDX/Col Dimension 440mm(W)*225mm(D)*44.5mm(H) Power 100~240 VAC 50/60HZ EMI & Safety FCC Class A, CE, UL

Ask about the LevelOne GSW-2490TXM

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LevelOne GSW-2490TXM

Be the first to ask — other owners or our team will answer.

Original document

LevelOne GSW-2490TXM manual PDF

57 pages·1.1 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…