EN
LevelOne logo
Official user manual

LevelOne FSW-1610TX

23 pages·123 KB·Switch·PDF·ENDEFRITNLJA
LevelOne FSW-1610TX
Table of Contents 11 sections LevelOne · FSW-1610TX FSW-2410TX · 16/24 Port 10/100Mbps Fast Ethernet Switch User’s Guide · FCC Warning · … ShowHide
Page 1 of the LevelOne FSW-1610TX user manual — LevelOne
Page 1 · click to enlarge
Page 1

LevelOne

FSW-1610TX FSW-2410TX

16/24 Port 10/100Mbps Fast Ethernet Switch User’s Guide

Page 2 of the LevelOne FSW-1610TX user manual — FCC Warning
Page 2 · click to enlarge
Page 2

FCC Warning

This equipment has been tested and found to comply with the regulations for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this user’s guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. CE Mark Warning

This is a Class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

LevelOne FSW-1610TX — FCC Warning diagram (page 2)
Fig. 1 · FCC Warning
Page 3 of the LevelOne FSW-1610TX user manual — FCC Warning
Page 3 · click to enlarge
Page 3
Page 3 of the LevelOne FSW-1610TX user manual — FCC Warning
Page 4 of the LevelOne FSW-1610TX user manual — TECHNICAL SPECIFICATIONS ......................................................26
Page 4 · click to enlarge
Page 4

B. Using crossover cable 24 PORT SPEED & DUPLEX MODE 25

TECHNICAL SPECIFICATIONS 26

Page 5 of the LevelOne FSW-1610TX user manual — A BOUT T HIS G UIDE
Page 5 · click to enlarge
Page 5

A BOUT T HIS G UIDE

Congratulations on your purchase of the LevelOne FSW- 1610/2410TFX 16/24Port 10/100Mbps Fast Ethernet Switch. This device integrates 100Mbps Fast Ethernet and 10Mbps Ethernet network capabilities in a highly flexible package.

This guide discusses how to install your LevelOne 16/24Port 10/100Mbps Fast Ethernet Switch.

In this guide, the term “Switch” (first letter upper case) refers to your LevelOne 16/24Port 10/100Mbps Fast Ethernet Switch, and ”switch” (first letter lower case) refers to other Ethernet switches.

This guide provides the information you need to install and configure the following models of the Switch:

§ LevelOne FSW-1610TX 16Port 10/100Mbps Fast Ethernet Switch

§ LevelOne FSW-2410TX 24Port 10/100Mbps Fast Ethernet Switch

The functionality of three units is identical, except for the number of ports. Where appropriate, differences between the two units are noted.

Purpose · Terms/Usage

Page 6 of the LevelOne FSW-1610TX user manual — A BOUT T HIS G UIDE
Page 6 · click to enlarge
Page 6

Overview of this User’s Guide

Chapter 1, Introduction. Describes the Switch and its features.

Chapter 2, Unpacking and Installation. Helps you get started with the basic installation of the Switch.

Chapter 3, Identifying External Components. Describes the front panel, rear panel and LED indicators of the Switch.

Chapter 4, Connecting the Switch. Tells how you can connect the Switch to your Ethernet network.

Appendix A, Technical Specifications. Lists the technical (general, physical and environmental, and performance) specifications of the Switch.

Appendix B, RJ-45 Pin Specification. Describes the RJ-45 receptacle/connector and the straight and crossover cable connector.

Page 7 of the LevelOne FSW-1610TX user manual — I NTRODUCTION
Page 7 · click to enlarge
Page 7

I NTRODUCTION

This chapter describes the features of the Switch and some background information about Ethernet/Fast Ethernet switching technology.

The growing importance of LANs and the increasing complexity of desktop computing applications are fueling the need for high performance networks. A number of high-speed LAN technologies have been proposed to provide greater bandwidth and improve client/server response times. Among them, 100BASE-T (Fast Ethernet) provides a non-disruptive, smooth evolution from the current 10BASE-T technology. The non-disruptive and smooth evolution nature, and the dominating potential market base, virtually guarantee cost effective and high performance Fast Ethernet solutions in the years to come.

100Mbps Fast Ethernet is a new standard specified by the IEEE 802.3 LAN committee. It is an extension of the 10Mbps Ethernet standard with the ability to transmit and receive data at 100Mbps, while maintaining the CSMA/CD Ethernet protocol. Since the 100Mbps Fast Ethernet is compatible with all other 10Mbps Ethernet environments, it provides a straightforward upgrade and takes advantage of the existing investment in hardware, software, and personnel training.

Fast Ethernet Technology

Page 8 of the LevelOne FSW-1610TX user manual — I NTRODUCTION
Page 8 · click to enlarge
Page 8

Another approach to pushing beyond the limits of Ethernet technology is the development of switching technology. A switch bridge Ethernet packets at the MAC address level of the Ethernet protocol transmitting among connected Ethernet or Fast Ethernet LAN segments.

Switching is a cost-effective way of increasing the total network capacity available to users on a local area network. A switch increases capacity and decreases network loading by dividing a local area network into different segments, which don’t compete with each other for network transmission capacity.

The switch acts as a high-speed selective bridge between the individual segments. The switch, without interfering with any other segments, automatically forwards traffic that needs to go from one segment to another. By doing this the total network capacity is multiplied, while still maintaining the same network cabling and adapter cards.

For Fast Ethernet networks, a switch is an effective way of eliminating problems of chaining hubs beyond the “two- repeater limit.” A switch can be used to split parts of the network into different collision domains, making it possible to expand your Fast Ethernet network beyond the 205-meter network diameter limit for 100BASE-TX networks. Switches supporting both traditional 10Mbps Ethernet and 100Mbps Fast Ethernet are also ideal for bridging between the existing 10Mbps networks and the new 100Mbps networks.

Switching Technology

Page 9 of the LevelOne FSW-1610TX user manual — I NTRODUCTION
Page 9 · click to enlarge
Page 9

Switching LAN technology is a marked improvement over the previous generation of network bridges, which were characterized by higher latencies. Routers have also been used to segment local area networks, but the cost of a router, the setup and maintenance required make routers relatively impractical. Today switches are an ideal solution to most kinds of local area network congestion problems.

The Switches were designed for easy installation and high performance in an environment where traffic on the network and the number of user increase continuously.

The Switches with its rack size is specifically designed for middle to large workgroups. These Switches provide immediate access to a rapidly growing network through a wide range of user-reliable functions.

The Switches are ideal for deployment with multiple high- speed servers for shared bandwidth 10Mbps or 100Mbps workgroups. With the highest bandwidth 200Mbps (100Mbps full-duplex mode), any port can provide workstations with a congestion-free data pipe for simultaneous access to the server.

The Switches are expandable by cascading two or more switches together. As all ports support 200Mbps, the Switches can be cascaded from any port and to any number of switches.

The Switches are a perfect choice for site planning to

Features

Page 10 of the LevelOne FSW-1610TX user manual — I NTRODUCTION
Page 10 · click to enlarge
Page 10

upgrade to Fast Ethernet in the future. Ethernet workgroups can connect to the Switches now, and change adapters and hubs anytime later without needing to change the Switches or reconfigure the network.

The Switches combine dynamic memory allocation with store-and-forward switching to ensure that the buffer is effectively allocated for each port, while controlling the data flow between the transmit and receive nodes to guarantee against all possible packet loss.

The Switches are an unmanaged 10/100 Fast Ethernet Switch offering solutions in accelerating small Ethernet workgroup bandwidth. Other key features are:

Auto-MDI function supports automatic MDI/MDIX crossover detection function gives true ‘plug and play’ capability without the need of confusing crossover cables or crossover ports.

Store and forward switching scheme capability. As the result of complete frame checking and error frame filtering, this scheme prevents error packages from transmitting among segments.

NWay Auto-negotiation for any port. This allows for auto-sensing of speed (10/100Mbps) thereby providing you with automatic and flexible solutions in your network connections.

Flow control for any port. This minimizes dropped packets by sending out collision signals when the port’s receiving buffer is full. Note that flow control is only available in half duplex mode.

Data forwarding rate per port is at wire-speed for 100Mbps speed.

Data forwarding rate per port is at wire-speed for 10Mbps speed.

Data filtering rate eliminates all error packets, runts, etc., per port

Page 11 of the LevelOne FSW-1610TX user manual — U NPACKING AND I NSTALLATION
Page 11 · click to enlarge
Page 11

at wire-speed for 100Mbps speed.

Data filtering rate eliminates all error packets, runts, etc., per port at wire-speed for 10Mbps speed.

Up to 8K active MAC address entry table with self-learning and table-aging for 16-port model and 24-port model.

512KB RAM buffer per device for 16-port model and 24-port model

U NPACKING AND I NSTALLATION

This chapter provides unpacking and setup information for the Switches.

Open the shipping cartons of the Switch and carefully unpacks its contents. The carton should contain the following items:

One the LevelOne FSW-1610/2410TFX 16/24Port 10/100Mbps Fast Ethernet Switch

One AC power cord, suitable for your area’s electrical power connections

Four rubber feet to be used for shock cushioning

Screws and two mounting brackets

If any item is found missing or damaged, please contact your local reseller for replacement.

Unpacking · This User’s Guide

Page 12 of the LevelOne FSW-1610TX user manual — U NPACKING AND I NSTALLATION
Page 12 · click to enlarge
Page 12

The site where you install the hub stack may greatly affect its performance. When installing, consider the following pointers:

Install the Switch in a fairly cool and dry place. See Appendix B for the acceptable temperature and humidity operating ranges.

Install the Switch in a site free from strong electromagnetic field generators (such as motors), vibration, dust, and direct exposure to sunlight.

Leave at least 10cm of space at the front and rear of the hub for ventilation.

Install the Switch on a sturdy, level surface that can support its weight, or in an EIA standard-size equipment rack. For information on rack installation, see the next section, Rack Mounting. When installing the Switch on a level surface, attach the rubber feet to the bottom of each device. The rubber feet cushion the hub and protect the hub case from scratching.

Installation

Page 13 of the LevelOne FSW-1610TX user manual — Rack Mounting
Page 13 · click to enlarge
Page 13

Rack Mounting

The switch can be mounted in an EIA standard-size, 19-inch rack, which can be placed in a wiring closet with other equipment. Attach the mounting brackets at the switch’s front panel (one on each side), and secure them with the provided screws.

LevelOne FSW-1610TX — Rack Mounting diagram (page 13)
Fig. 2 · Rack Mounting

Then, use screws provided with the equipment rack to mount each switch in the rack.

Page 14 of the LevelOne FSW-1610TX user manual — Rack Mounting
Page 14 · click to enlarge
Page 14
LevelOne FSW-1610TX — Rack Mounting diagram (page 14)
Fig. 3 · Rack Mounting

This section identifies all the major external components of the switch. Both the front and rear panels are shown, followed by a description of each panel feature. The indicator panel is described in detail in the next chapter.

Identifying External Components

Page 15 of the LevelOne FSW-1610TX user manual — Rack Mounting
Page 15 · click to enlarge
Page 15

The figure below shows the front panels of the switches.

16-port 10/100M Fast Ethernet Switch

24-port 10/100M Fast Ethernet Switch

Refer to the next chapter for detailed information about each of the switch’s LED indicators.

l Auto-MDI/MDIX Jacks: These jacks supports automatic MDI/MDIX crossover detection function gives true ‘plug and play’ capability without the need of confusing crossover cables or crossover ports.

With the Auto-MDI/MDIX function, you just need to plug-in the network cable to the hub directly and no need to care if the end node is NIC (Network Interface Card) or switches and hubs.

Front Panel · LED Indicator Panel · Rear Panel

Page 16 of the LevelOne FSW-1610TX user manual — Rack Mounting
Page 16 · click to enlarge
Page 16

LevelOne 16/24 Port 10/100Mbps Fast Ethernet Switch

AC Power Connector:

For the power cord.

Page 17 of the LevelOne FSW-1610TX user manual — Rack Mounting
Page 17 · click to enlarge
Page 17

This LED lights green when the switch is receiving current; if not, power is off.

100M Link/Activity, 10M Link/Activity (100M LINK/ACT(green), 10LINK/ACT(yellow))

This indicator light green when the port is connected to a 100Mbps Fast Ethernet station, if the indicator blinking green will be transmitting or received data on the 100Mbps network. Otherwise, if the indicator light amber when the port is connected to a 10Mbps Ethernet station, if the indicator blinking amber will be transmitting or received data on the 10Mbps network.

Full/Half Duplex, 10/100M Collision (10/100M FDX(green),10/100M COL(blinking))

This LED indicator lights green when a respective port is in full duplex (FDX) mode. Otherwise, it is OFF for half duplex (HDX) operations. It blinking green when collisions are occurring on the respective port.

LED Indicators · Power Indicator (PWR)

Page 18 of the LevelOne FSW-1610TX user manual — C ONNECTING T HE S WITCH
Page 18 · click to enlarge
Page 18

C ONNECTING T HE S WITCH

This chapter describes how to connect the Switch to your Fast Ethernet network.

A PC can be connected to the Switch via a two-pair Category 3, 4, 5 UTP/STP straight cable. The PC (equipped with a RJ- 45 10/100Mbps phone jack) should be connected to any of the 16 ports (1x - 16x) for the 16Port model, 24 ports (1x - 24x) for the 24Port model

The LED indicators for PC connection dependent on the LAN card capabilities. If LED indicators are not light after making a proper connection, check the PC LAN card, the cable, the Switch conditions and connections.

The following are LED indicator possibilities for a PC to Switch connection:

1. The “100M LINK/ACT, 10M LINK/ACT” LED indicator light green for hookup to 100Mbps speed or light amber for hookup to 10Mbps speed.
2. The “10/100M FDX, 10/100M COL LED” indicator depends upon LAN card capabilities for full-duplex or half-duplex.

A hub (10 or 100BASE-TX) can be connected to the Switch

PC to Switch · Hub to Switch

Page 19 of the LevelOne FSW-1610TX user manual — C ONNECTING T HE S WITCH
Page 19 · click to enlarge
Page 19

via a two-pair Category 3, 4, 5 UTP/STP cable. The connection is accomplished from the hub uplink (MDI-II) port to any port of the Switch (MDI-X) ports.

A. 10BASE-T Hub

For a 10BASE-T hub, the Switch LED indicators should light up as the following:

“10/100M FDX, 10/100M COL” LED indicator is OFF.

“100M LINK/ACT, 10LINK/ACT” LED indicator is light amber.

B. 100BASE-TX Hub

For a 100BASE-TX hub, the Switch LED indicators should light up as the following:

“10/100M FDX, 10/100M COL” LED indicator is OFF.

“100M LINK/ACT, 10M LINK/ACT” LED indicator is light green.

Page 20 of the LevelOne FSW-1610TX user manual — C ONNECTING T HE S WITCH
Page 20 · click to enlarge
Page 20

Switch to Switch (other devices)

The Switch can be connected to another switch or other devices (routers, bridges, etc.) via a two-pair Category 3, 4, 5 UTP/STP straight or crossover cable.

A. Using straight cable

When using straight cable, this is done from the uplink (MDI-II) port of other Switch to any of the 10Mbps or 100Mbps (AUTO MDI-X) port of FSW-1610TX/ 2409TFX.

B. Using crossover cable

When using crossover cable, this is done from any (MDI-X) port of the Switch (Switch A) to any of the 10Mbps, 100Mbps (AUTO MDI-X) port of FSW-1610TX/ 2409TFX.

1. The “100M LINK/ACT, 10M LINK/ACT” LED indicator light green for hookup to 100Mbps speed or light amber for hookup to 10Mbps speed.
2. The “10/100M FDX, 10/100M COL” LED indicator depends upon LAN card capabilities for full-duplex or half-duplex
Page 21 of the LevelOne FSW-1610TX user manual — C ONNECTING T HE S WITCH
Page 21 · click to enlarge
Page 21

Port Speed & Duplex Mode

After plugging the selected cable to a specific port, the system uses auto-negotiation to determine the transmission mode for any new twisted-pair connection:

If the attached device does not support auto- negotiation or has auto-negotiation disabled, an auto- sensing process is initiated to select the speed and set the duplex mode to half-duplex.

Page 22 of the LevelOne FSW-1610TX user manual — T ECHNICAL S PECIFICATIONS
Page 22 · click to enlarge
Page 22

T ECHNICAL S PECIFICATIONS

Standards IEEE 802.3 10Base-T Ethernet

IEEE 802.3u 100 Base-TX Fast Ethernet

ANSI/IEEE 802.3 NWay auto-negotiation

Ethernet10Mbps (half duplex)
Fast Ethernet100Mbps (half duplex)
10BASET2-pair UTP Cat. 3,4,5 (100 m), EIA/TIA568 100-ohm STP (100 m)
100BASE-TX2-pair UTP Cat. 5 (100 m), EIA/TIA-568 100ohm STP (100 m)
100BASE-FX62.5/125 micron multimode fiber optic (2km)
16-port16 x 10/100Mbps NWay ports
24-port24 x 10/100Mbps NWay ports
Show 8 more labels / short text on this page
General · Protocol CSMA/CD · Data Transfer Rate · 20Mbps (full duplex) · 200Mbps (full duplex) · Topology Star · Network Cables · Number of Ports
Page 23 of the LevelOne FSW-1610TX user manual — T ECHNICAL S PECIFICATIONS
Page 23 · click to enlarge
Page 23
LevelOne FSW-1610TX — T ECHNICAL S PECIFICATIONS diagram (page 23)
Fig. 4

AC inputs 100 to 240 VAC, 50 or 60 Hz internal universal power supply

Temperature Operating0 ° ~ 50 ° C, Storage: -10 ° ~ 70 ° C
Humidity Operating10% ~ 90%, Storage: 5% ~ 90%

Dimensions 440 x 200 x 44 mm (W x H x D)

EMIFCC Class A, CE Mark , VCCI Class A

Ask about the LevelOne FSW-1610TX

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LevelOne FSW-1610TX

Be the first to ask — other owners or our team will answer.

Original document

LevelOne FSW-1610TX manual PDF

23 pages·123 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…