Page 1 of the LevelOne FSW-0800FXT user manual — LevelOne
Page 1 · click to enlarge
Page 1

LevelOne

FSW-0800FXC

FSW-0800FXT

FSW-1600FXC

FSW-1600FXT

8/16 Port 100Mbps Fast Ethernet Switch with

SC/ST Connector

User’s Guide

Page 2 of the LevelOne FSW-0800FXT user manual — Federal Communications Commission (FCC) Statement
Page 2 · click to enlarge
Page 2

Caution

  • Circuit devices are sensitive to static electricity, which can damage their delicate electronics. Dry weather conditions or walking across a carpeted floor may cause you to acquire a static electrical charge. To protect your device, always:
  • Touch the metal chassis of your computer to ground the static electrical charge before you pick up the circuit device.
  • Pick up the device by holding it on the left and right edges only.

Electronic Emission Notices

Federal Communications Commission (FCC) Statement

This equipment has been tested and found to comply with the limits for a class A computing device pursuant to Subpart J of part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment European Community (CE) Electromagnetic Compatibility Directive

This equipment has been tested and found to comply with the protection requirements of European Emission Standard EN55022/EN60555-2 and the Generic European Immunity Standard EN50082-1 that calls up the following basic standards: a) IEC801-2 Electrostatic Discharge b) IEC801-3 RF Immunity c) IEC801-4 Transient Burst

Page 3 of the LevelOne FSW-0800FXT user manual — Contents
Page 3 · click to enlarge
Page 3

Contents

Overview 1-1 Model Description 1-1 Checklist 1-1 Front Panel 1-2 Chapter 2 Installing & Network Connection 2-1

Installation 2-1 Network Parameter for 100Mbps Fiber 2-1 Switch Hub Cascading and Long Haul Connection 2-2 Fiber Port Full/Half-duplex DIP Switch Setup 2-3 LED Indicators 2-4 Chapter 3 Troubleshooting 3-1

Cabling Problems 3-1 Workstation Problems 3-2 Other Problems 3-2 Appendix A-1

Technical Specifications A-1

Page 4 of the LevelOne FSW-0800FXT user manual — Models Description
Page 4 · click to enlarge
Page 4

1-1 Chapter 1 Introduction

Overview

The Levelone 8/16 Port Fiber Switch is a standard switch that meets all IEEE 802.3u/802.3x specifications. Fast Ethernet Switch is a cost-effective solution for easing your network congestion problem on existing shared-hub network by breaking up the collision domain and by multiplying the network performance. The overall network transmission speed is increased and the network efficiency is improved to accommodate high-bandwidth applications, such as imaging, multimedia, and CAD/CAM, etc.. Four models are available:

FSW-0800FXC

8 Port 100Mbps Fast Ethernet Switch with SC Connector 8 Port 100Mbps Fast Ethernet Switch with ST Connector

FSW-0800FXT FSW-1600FXC 16 Port 100Mbps Fast Ethernet Switch with SC Connector

FSW-1600FXT 16 Port 100Mbps Fast Ethernet Switch with ST Connector

Models Description

Configuration16 Fiber8 Fiber 100FX Fiber Jack168 10/100Mbps TP JackNoneNone

The available Fiber Transceiver(Jack) for switch:

SC/ST multi-mode SC single-mode

Checklist Before you start installing the Fiber Switch, verify that the package contains the following items:

¾ 1 LevelOne 8/16 Port 10/100Mbps Fast Ethernet Switch ¾ Mounting Accessory (for 19" Rack Shelf) ¾ AC Power Cord ¾ This User’s Manual Please notify your sales representative immediately if any of the aforementioned items is missing or damaged.

Default optional

Page 5 of the LevelOne FSW-0800FXT user manual — Network Parameter for 100Mbps Fiber
Page 5 · click to enlarge
Page 5

2-1 Chapter 2

Installing & Network Connection

Installation

Þ The fiber TX, RX cables must be paired at both ends.

Þ Repeat the above step, as needed, for each fiber port to be connected to

a 100Base-FX device. Þ The fiber port can be up-linked to an upper level hub's port.

Þ Verify that the voltage of AC power is correct and plug in AC power cord.

1. Both local and remote link devices (mode) must operate at the same transmission mode and speed After the hub is powered off, wait at least 10 seconds before powering it

Network Parameter for 100Mbps Fiber

To help ensure a successful installation, you must observe the following cabling parameter. Violating these rules can render the LAN to work poorly.

Þ 100Base-FX fiber network connection

LevelOne FSW-0800FXT — Network Parameter for 100Mbps Fiber diagram (page 5)
Fig. 1 · Network Parameter for 100Mbps Fiber
Full-duplex Switch via Fiber Multi-modeNode to Node : 2km Hub to Hub : 2km Node to Hub : 2km Single-modeNode to Node : 15km Node to Hub : 15km Hub to Hub : 15km Half-duplex Switch via Fiber Multi or single-modeNode to Node : 412m Node to Hub : 412m Hub to Hub : 412m Half-duplex Class II Hub via Fiber Multi or single-modeNode to Node : 205m Node to Hub : 100m Hub to Hub : 5m

on again

Page 6 of the LevelOne FSW-0800FXT user manual — Cabling Problems
Page 6 · click to enlarge
Page 6

3-1 Chapter 3

Troubleshooting

Network troubleshooting requires patience and logic. Generally speaking, the cabling and workstation configurations are the likely first suspects; network hardware is usually last on the list. The nature of the hub design dictates that it is more likely for an entire hub to fail instead of just a single port.

Cabling Problems

  • Improper Cabling is the primary cause of most non-workstation problems on Ethernet network, particularly for 100 Base-FX networks. It must be emphasized that genuine twisted-pair cable and fiber optic cable be used to avoid many types of cabling problems
  • Wiring is definitely the problem if the Link LED does not light when the fiber plug from a workstation is inserted into the port jack. Either correct the break in the wire or replace the wire before proceeding
  • Multi or single-mode fiber cable should match the switch's fiber transceiver.
  • If a workstation (workstation A) does not work and other 100Base-X ports on the hub are functioning, remove a fiber plug from a functioning port with a functioning workstation (workstation B) and insert it into the suspect port. If workstation B still works, the problem is in workstation A or in the wiring. However, if workstation B does not work, then the hub may have a defective port. Even if you suspect a defective port on the hub, continue testing. Improperly wired workstations may appear to be functional, especially if they are located near the hub. Sometimes, a port connected to an improperly wired workstation can function marginally while another port may not work at all
  • Once you have established that the hub is working properly, check all wiring between the hub and the malfunctioning workstation. Ensure that the transmit and receive wires have not been crossed; the two transmit wires should be paired together as should the two receive wires
  • Use a continuity checker to ensure that wires do not have breaks. By shorting together the two wires of a pair at one end, you can use the continuity checker at the other end. Also, check that there are no shorts between wires
Page 7 of the LevelOne FSW-0800FXT user manual — A-1 16 Port Fiber Switch Technical Specifications
Page 7 · click to enlarge
Page 7

A-1 16 Port Fiber Switch Technical Specifications

Standards Compliance : IEEE802.3u and 802.3x 100Base-FX Transmission Mode : Full or Half duplex Transmission Speed : 100Mbps Packet forwarding/filtering Rate:

148,800 packets / sec full wire rate on 100Mbps forwarding and filtering MAC Address and Self-learning: up to 12K Buffer Memory : 1024KB for 16 ports Flow control : IEEE802.3x compliant for full-duplex

Back pressure flow control for half-duplex Network Interface :

¾ 16ST.M : Sixteen ST multi-mode fiber ports ¾ 16SC.M : Sixteen SC multi-mode fiber ports ¾ 16SC.S : Sixteen SC single-mode fiber ports

Cable and Maximum length:

50/125, 62.5/125 or 100/140mm multi-mode, up to 2Km FX(Fiber) 8.3/125, 8.7/125, 9/125 or 10/125mm single-mode, up to 15Km

Selectable Duplex Mode SwitchPer fiber port FDX/HDX DIP switch Diagnostic LED:
System LEDPower Per Port LED : Link/Act, 100Mbps, FDX/Col Power Requirement : AC Line

Voltage : 100~240 V Frequency : 50~60 Hz Consumption : 65W Max.

Ambient Temperature : 0° to 50°C Humidity : 5% to 90% Dimensions : 44(H) ´ 440(W) ´ 200(D) mm Complies with FCC Part 15 Class A & CE Mark Approval

Page 8 of the LevelOne FSW-0800FXT user manual — A-2 8 Port Fiber Switch Technical Specifications
Page 8 · click to enlarge
Page 8

A-2 8 Port Fiber Switch Technical Specifications

Standards Compliance : IEEE802.3u and 802.3x 100Base-FX Transmission Mode : Full or Half duplex Transmission Speed : 100Mbps Packet forwarding/filtering Rate:

148,800 packets / sec full wire rate on 100Mbps forwarding and filtering MAC Address and Self-learning: up to 12K Buffer Memory : 1024KB for 8 ports Flow control : IEEE802.3x compliant for full-duplex

Back pressure flow control for half-duplex Network Interface :

¾ 8ST.M : Eight ST multi-mode fiber ports ¾ 8SC.M : Eight SC multi-mode fiber ports ¾ 8SC.S : Eight SC single-mode fiber ports

Cable and Maximum length:

50/125, 62.5/125 or 100/140mm multi-mode, up to 2Km FX(Fiber) 8.3/125, 8.7/125, 9/125 or 10/125mm single-mode, up to 15Km

Selectable Duplex Mode SwitchPer fiber port FDX/HDX DIP switch Diagnostic LED:
System LEDPower Per Port LED : Link/Act, 100Mbps, FDX/Col Power Requirement : AC Line

Voltage : 100~240 V Frequency : 50~60 Hz Consumption : 43W Max.

Ambient Temperature : 0° to 50°C Humidity : 5% to 90% Dimensions : 44(H) ´ 440(W) ´ 200(D) mm Complies with FCC Part 15 Class A & CE Mark Approval

Page 9 of the LevelOne FSW-0800FXT user manual — Hub Diagnostic Test
Page 9 · click to enlarge
Page 9
  • Most non-cabling problems result from improper configuration of the network interface card (NIC) and its corresponding driver. The following points will be helpful:
  • Like other add-on cards in the workstation or server, NIC must have unique memory address, I/O address, and interrupt. The settings on a particular card must not conflict with the settings on any other card in the same station. Please refer the User's manual of the NIC, computers, and Networking operating systems to determine the proper configuration
  • The selection of half or full duplex, the speed of 10 or 100Mbps for the NIC setting must match the mode and speed setting of the corresponding port of the Hub. For NWay Auto-Negotiation setting, both link partners will auto-adjust to the highest allowable speed and mode operation

Other Problems

Other specific problems may be diagnosed by using the LEDs, as below. Power LED is off when the AC Power switch is ON:

  • Defective power supply unit or fuse
  • Incorrect AC voltage
  • Defective Hub Link/Act LED is off at any Fiber:
  • Faulty node or wiring connection For fiber - the "TX", "RX" cables should be paired at both ends No Link signal is received from the remote node/site 100Base-X Port at irregular traffic:
  • Abnormal or invalid transmission status(mode / speed) between local and remote link partners, i.e., full-duplex port is connecting to a half-duplex port, or 10Mbps port is connecting to a 100Mbps device

Hub Diagnostic Test

The switch hub performs self-diagnostic test at major hub modules upon

power on, LED indicators will go to normal status if no problem occurred To reset or restart the hub, power off the hub and wait for 10 seconds, then

power on it again

3-2 Workstation Problems

Page 10 of the LevelOne FSW-0800FXT user manual — Workstation Problems
Page 10 · click to enlarge
Page 10

For connection to Router, Bridge, or regular 100Base-X Hub, please refer to the device’s Technical Manual for respective bit-time delay.

Switch Hub Cascading and Long-Haul Connection Theoretically, the switch hub breaks up the collision domain in hub cascading that you may up-link the hubs unlimitedly. In practice, the network extension (cascading levels & overall diameter) is limited by the timing requirement--time-out specification--of your application software and network operating system. A hierarchical network with minimum levels of hub may reduce the timing delay between server and client station. If more than two hubs are connected in the same room, select one hub as Level 1 hub and connect all other hubs to it at Level 2. Server/Host is recommended to connect to the Level 1 hub. By following this approach, it will minimize the number of hubs in any one path and will improve network efficiency. (See Fig. 2-1)

The fiber switch(single mode transceiver) with single mode fiber can provide the long haul connection up to 15km per segment, you may extend the distance by cascading the switch and meet the timing requirement of your application software. Sum up all elements’ bit-time delay and the overall bit-time delay of wires/devices must be within 512 bit in a 100Base-X network segment (collision domain). The fiber cables and devices’ bit-time delay(round trip) is as below:

LevelOne FSW-0800FXT — Workstation Problems diagram (page 10)
Fig. 2 · Workstation Problems
100Base-TX100Base-FX DTE«DTE:100DTE«DTE:100 Class II Hub:92Class II Hub:92 Cat. 5 TP Wire:1.112/mFiber Cable:1.0/m DTE FX to DTE TX :100 100Base-TX to 100Base-FX Converter: 56
Page 11 of the LevelOne FSW-0800FXT user manual — HDX
Page 11 · click to enlarge
Page 11
LevelOne FSW-0800FXT — Workstation Problems diagram (page 11)
Fig. 3 · Workstation Problems

TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX

16 Port 100Mbps Fast Ethernet Switch with SC Connector 9 10 11 12 13 14 15 16

8 Port 100Mbps Fast Ethernet Switch with SC Connector

TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX

TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX

16 Port 100Mbps Fast Ethernet Switch with SC Connector 9 10 11 12 13 14 15 16

Every fiber port is FDX/HDX selectable by DIP switches, the default setting is FDX. You may force each fiber port into either FDX or HDX. Two typical modes between local and remote fiber devices are:

Local Fiber Port Remote Fiber Port Full-duplex Full-duplex Half-duplex Half-duplex

2 1 4 5 6 7 8 3

HDX

respectively. ¾ To alter the duplex mode, power down the hub and select the DIP switch

Level 1 · (Default) FDX

Page 12 of the LevelOne FSW-0800FXT user manual — Workstation Problems
Page 12 · click to enlarge
Page 12

2-4 mode setting. Then, power on to restart the new configuration and status.

Page 13 of the LevelOne FSW-0800FXT user manual — 2-5 LED Indicators
Page 13 · click to enlarge
Page 13

2-5 LED Indicators

The status and descriptions of LED indicators are listed as below:

LevelOne FSW-0800FXT — 2-5 LED Indicators diagram (page 13)
Fig. 4 · 2-5 LED Indicators

8 Port 100Mbps Fast Ethernet Switch with SC Connector PWR

LevelOne FSW-0800FXT — 2-5 LED Indicators diagram (page 13)
Fig. 5 · 2-5 LED Indicators

PWR Green Lit when AC power is on and good

Link/Act Green Lit when connection with remote device is good Blinks when any traffic is present

FDX/Col Amber Lit when full-duplex mode is active Blinks when any collision signal is present

Table 2-1 LED indicators description and status

The 8/16 port switch LED indicators are the same as Table 2-1 except the port capacity and associated LED indicators.

Page 14 of the LevelOne FSW-0800FXT user manual — HDX
Page 14 · click to enlarge
Page 14

1 2 3 4 5 6 7 8 2 1 4 5 6 7 8 3

FDX

F D X /Col

1 2 3 4 5 6 7 8

HDX

TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX

FDX

9 10 11 12 13 14 15 16

F D X /Col

P O W E R

9 10 11 12 13 14 15 16

HDX

9 10 11 12 13 14 15 16

Fig. 1-1 Front view of 16 Port ST/SC Fiber Switch

Fast Ethernet Switching Hub

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

FDX

2 1 4 5 6 7 8 3

P O W E R

F D X /C o l

HDX

TX RX TX RX TX RX TX RX TX RX TX RX TX RX TX RX

Fig. 1-2 Front view of 8 Port ST/SC Fiber Switch

LevelOne FSW-0800FXT — HDX diagram (page 14)
Fig. 6

1/MPR 2 3 4 5 6 7 8 1/DTE

Fig. 1-3 Front view of 8 TP with 2 Fiber ST/SC Switch

Fast Ethernet Switching Hub

1 2 3 4

2 1 4 3 2 1 4 3

FDX

F D X /C o l

HDX

POWER

TX RX TX RX TX RX TX RX

Fig. 1-4 Front view of 4 Port Fiber ST/SC Switch

Fast Ethernet Switching Hub

1 2 3 4 Link/Act

1 2 3 4

2 1 4 3 FDX

F D X /C o l

HDX

POWER

Fig. 1-5 Front view of 4 Port Fiber MT-RJ Switch

Show 9 more labels / short text on this page
Link/Act · 100Mbps · 100Mbps · Link/Act · Link/Act · 100Mbps · Link/Act · 100Mbps · 100Mbps

Ask about the LevelOne FSW-0800FXT

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LevelOne FSW-0800FXT

Be the first to ask — other owners or our team will answer.

Original document

LevelOne FSW-0800FXT manual PDF

14 pages·1.8 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…