07/10 *2P0710* 506454−01 *P506454-01* SLP98DFV SERIES Litho U.S.A. 506454−01 07/2010 WHAT TO DO IF YOU SMELL GAS: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Installation and service must be per- formed by a qualified installer, ser- vice agency or the gas supplier.
Page 2 SLP98DFV Parts Identification DURALOK TM HEAT EXCHANGER ASSEMBLY BURNERS VARIABLE SPEED BLOWER MOTOR CABINET GAS VALVE AND MANIFOLD VARIABLE SPEED COMBUSTION AIR INDUCER FLUE COLLAR TOP CAP SURELIGHT ® INTEGRATED CONTROL FIGURE 1 PRESSURE SWITCH ASSEMBLY AIR INTAKE COLLAR NOTE − This manual must be left with the equipment user.
Page 3 WARNING Product contains fiberglass wool. Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiberglass wool. Breathing this may cause lung cancer. (Fiberglass wool i s known to the State of Cal- ifornia to cause cancer.
Page 4 WARNING Carbon m onoxide gas is invisible, odorless and tox- ic. Exposure to carbon monoxide gas can cause personal in- jury and even death to all occupants, including pets.
Page 5 NOTE − When unit is initially started, steps 1 through 11 may need to be repeated to purge air from gas line. 12− If the appliance will not operate, follow the section Turning Off Gas to the Unit" and call your service tech- nician or gas supplier.
Page 6 Burner Flame CAUTION To ensure proper operation, a licensed professional service technician (or equivalent) should check the burner flame and conduct a combustion analysis annually. Electrical 1 − Check all wiring for loose connections. 2 − Check for the correct voltage at the furnace (furnace operating).
Page 7 Repair Parts List The following repair parts are available through Lennox dealers. When ordering parts, include the complete furnace model number listed on the CSA International nameplate −− Example: SLP98DF070V36B. All service must be done by a li- censed professional installer (or equivalent), a service agency, or the gas supplier.
An important point after buying a device Lennox International Inc. Variable Capacity Gas Furnace (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Lennox International Inc. Variable Capacity Gas Furnace yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Lennox International Inc. Variable Capacity Gas Furnace - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Lennox International Inc. Variable Capacity Gas Furnace you will learn all the available features of the product, as well as information on its operation. The information that you get Lennox International Inc. Variable Capacity Gas Furnace will certainly help you make a decision on the purchase.
If you already are a holder of Lennox International Inc. Variable Capacity Gas Furnace, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Lennox International Inc. Variable Capacity Gas Furnace.
However, one of the most important roles played by the user manual is to help in solving problems with Lennox International Inc. Variable Capacity Gas Furnace. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Lennox International Inc. Variable Capacity Gas Furnace along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center