Your Digiplex Security System is an advanced technology security system that will provide you with reliable security protection and powerful features that are easy to use. The elegant and user-friendly LCD keypad will allow you easy access to your security system's functions and information at the touch of a button. The 32-character LCD screen will display messages and menus to guide you through the system’s operations. Your Installer can even customize the messages for your home or business.
Since you will communicate your instructions to your system through the keypad, please read this manual carefully and have your Installer explain basic system operation.
If you have the InTouch Voice Assisted Arm/Disarm Module (APR3-ADM2) connected to your Digiplex security system, please refer to page 19 for operating instructions.
Indicates a warning or an important note.
Indicates useful information or a tip.
[SQUARE BRACKETS] Indicates information that must be entered on the keypad.
The following sections will introduce you to the roles of the buttons, lights, and messages on your LCD keypad.
The LCD screen will guide you with detailed messages.

“STATUS” LIGHT: When Green: ON = All zones are closed. OFF = One or more zones are open. FLASH = Exit Delay When Red: ON = Area(s) armed OFF = Area(s) disarmed FLASH = System in Alarm
Use the arrow buttons to scroll through the current menu when the arrows appear in the LCD screen.
ACTION BUTTONS: Each button’s function is explained in the following sections of the manual.
[ENTER] = Saves current data and exits current menu.
[CLEAR] = Erases current data entry or reverts to the preceding step.
2.1 AUDITORY FEEDBACK (BEEP TONES) When you enter information on the keypad, the keypad will guide you with beep tones to communicate the acceptance or rejection of your entries.
Confirmation Beep: When an operation (i.e. arming/disarming) is successfully entered or when the system switches to a new status/mode, the keypad emits an intermittent beep tone (“BEEP-BEEP-BEEP-BEEP-BEEP”).
Rejection Beep: When the system reverts to a previous status, or when an operation is incorrectly entered, the keypad emits a continuous beep tone (“BEEEEEEEEEEP”).

2.2 CONFIDENTIAL MODE Your Installer can program keypads to not display the status of your system automatically by changing the LCD screen to Confidential Mode. In Confidential Mode:
2.3 PARTITIONED SYSTEM A separated system is called a Partitioned System, which can be useful in situations where shared security systems are more practical. Your installer can design your system to recognize up to four separate protected areas. For example, a company that has both an office area and a warehouse area can arm and disarm each area separately and control the access to each area.
If you have access to more than one area, and you need to select a specific area(s) when prompted by your LCD keypad, follow either one of the following three methods to make your selection:
2.4 AREA STATUS DISPLAY The Area Status Display allows you to view the status of the selected areas in a Partitioned System (Refer to section 2.3 on page 5).
To view the Area Status Display:
In Area Status Display mode, the following information will scroll on the LCD screen:
When your system is armed, it can respond to any breach in the protected zones by causing an alarm and sending a report to your Central Monitoring Station.
3.1 EXIT DELAY TIMER When you arm your system, it will trigger the Exit Delay Timer to provide you with enough time to exit the protected area before the system is armed.
3.2 REGULAR ARMING This method is used for the everyday arming of your system. All zones within the protected area must be closed to Regular arm the system.

3.3 STAY ARMING Stay arming will partially arm your system to permit you to remain in your home or office by arming the outer zones (perimeter) of the protected area (i.e. doors and windows).
3.4 INSTANT ARMING This feature is the same as Stay arming except that there is no Entry Delay. Therefore, any armed zone that is breached will immediately generate an alarm.
3.5 FORCE ARMING Force arming allows you to quickly arm your system when zones are open. However, once the open zone is closed, your system will then arm that zone as well.
3.6 BYPASS PROGRAMMING You can bypass certain zones when you arm the protected area(s). When a zone is bypassed, it will be ignored the next time your system is armed. Once your area is disarmed, the system will unbypass the zone.
1. Enter your [ACCESS CODE]. 2. Press the [BYP] button. 3. Enter the zone number (i.e. 01, 02,...48), or use the [S] and [T] buttons and press [BYP] once the zone you want to bypass appears on the screen. If “bypassed” does not appear on the screen and the keypad emits a Rejection Beep, you may not have access to bypass that zone. 4. Repeat step 3 until all zones you want to bypass have been selected. 5. Press the [ENTER] button to save and exit.
In order to bypass a zone, the following conditions must be met: - The zone must have the Bypass option programmed by the installer. - Your User Access Code must be programmed to enable the Bypass option. - Your User Access Code must have access to the zone’s Area Assignment. - The zone’s area must be disarmed before the zone can be bypassed.
Fire Zones cannot be bypassed.
3.6.1 BYPASS RECALL Bypass Recall reinstates the zones that were bypassed the last time your system was armed.

3.7 ONE-TOUCH BUTTONS If enabled by your Installer, you can access the following features without using your User Access Code by pressing and holding the desired One-Touch button.
3.8 KEYSWITCH ARMING A key can be used to arm and disarm your system using two forms of keyswitches. With a Maintained Keyswitch, place the key in the “ON” position to arm your system, and place the key in the “OFF” position to disarm your system. With a Momentary Keyswitch, place the key in the “ON” position briefly then place it back in the “OFF” position to arm the system. Repeat this process to disarm with a Momentary Keyswitch.
3.9 AUTO-ARMING If enabled by your Installer, you can set the time that an area will arm itself automatically.
3.9.1 TIMED AUTO-ARMING Your installer can set Timed Auto-Arming to function in either Force or Stay arming mode. A sixty-second Exit Delay sequence will begin prior to your system automatically arming itself at the programmed time.
1. Enter your [ACCESS CODE]. 2. Press the [0] button. 3. Press the [MEM] button. 4. If you have access to more than one area, press the area’s number, or use the [S] and [T] buttons and press the [ACC] button when the area you want to program appears on the screen. 5. Enter the time you want the area to be armed according to the 24-hour clock (i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00). 6. Press the [ENTER] button to save and exit.
3.9.2 NO MOVEMENT AUTO-ARMING Your system can be programmed to send a report to your Central Monitoring Station and/or arm the system if there is no activity in the area during a specified period of time. Your installer can set No Movement Auto-Arming to function in either Regular or Stay arming mode.
When your system is disarmed, it deactivates any alarms in progress, and it deactivates the zones so the alarm will not be triggered if zones are breached.
4.1 ENTRY DELAY TIMER Your installer will program designated entry points (i.e. the front door) with an Entry Delay Timer. This delay gives you time to enter the armed premises and enter your code to disarm your system before the alarm is triggered.
4.2 DISARMING AN ARMED SYSTEM You can only disarm an area to which your User Access Code is assigned. User Access Codes with the “Arm Only” (section 5.4 on page 11) option enabled cannot disarm an armed system.
Tp Disarm the system:

To Disarm a system in alarm:
In the case of a burglar alarm, leave the premises and call the Police from a safe place.
4.3 ALARM MEMORY DISPLAY Your system will record all the alarms that occurred during the last armed period. The zones in alarm will remain in the Alarm Memory until the next time that area is armed.
When an alarm has occurred, the LCD screen will display “Alarms in Memory [MEM] to View”.
Access Codes allow access to the system. Your system supports up to 96 User Access Codes. Codes are given a User Number between 02 and 96 (User Number 01 is the System Master Code). Your Installer will program User Access Codes to be four, six, or variables of one to six digits in length. Each digit can be any value between zero and nine. If your Installer programmed your system to accept a variable code length, you have to press the [ENTER] button after entering your User Access Code.
5.1 SYSTEM MASTER CODE (Default 123456) The System Master Code will give you access to all the features available on your system, as well as the ability to add, modify, or delete any User Access Codes. We suggest that you change this code to prevent others from accessing and changing options without authorization. Your Installer can set The System Master Code to be either 4 or 6 digits in length.
To change the System Master Code:
The System Master Code has access to all Access Control Doors and all Access Control features at all times. Only the card’s serial number and the choice of arming method can be changed. If the other options are manually changed, the System Master Code will immediately revert to its original programming.
5.2 DELETING USER ACCESS CODES To delete User Access Codes, follow steps 1 to 5 in Figure 5.1 on page 9, but press the [CLEAR] button in step 5. Once the information is erased, press the [ENTER] button to save and exit.
5.3 PROGRAMMING USER ACCESS CODES The System Master and Users with the Master feature can program User Access Codes with User Options and Area Assignments. Figure 5.1 on page 9 describes the steps you would follow to program User Access Codes.
If the keypad emits a Rejection Beep at any point during the programming procedure, you may have chosen an existing User Code or you do not have access to certain User Options (section 5.4) and Area Assignments (step 7 in Figure 5.1 on page 9). User’s with the Master feature can only assign User Options and Area Assignments that they are assigned to. For example, if a User with the Master feature is assigned User Option 1 and Area 2, they can only assign Options 1 and Area 2 to a User Access Code.


Enter your [ACCESS CODE] (System Master Code or User Access Code with Master feature).

Press [0] to enter the Programming Menu.

From Programming Menu, press [ACC].

Enter the 2-digit User Number you want to program; press the [T] button to scroll the list of codes then press [ACC] once the desired code appears on the screen.

Enter a User Code within the brackets. Press the [S] button to reach the User Options screen. NOTE: The User Code is a Personal Identification Number (P.I.N.).

Program the User Options by pressing the number on your keypad corresponding to the User Option you wish to enable. The option is considered ON when the number appears within the brackets. Proceed to step 7 by pressing the [S] button. For a detailed description of the User Options refer to section 5.4 on page 11.
Option [3]: Duress Option [4]: Bypass Option [5]: Arm Only Option [6]: Stay and Instant Arm Option [7]: Force Arm Option [8]: OFF - Access keypad’s partitions only Option [8]: ON - Access any partition assigned to user
[1] OFF = Master Feature disabled. [1] ON, [2] OFF = User can only modify User Access Codes. [1] ON, [2] ON = User has full Master rights. User can create, modify, and program User options, User Access Options and Area Assignments.


Users are able to perform actions (arming, disarming, etc.) only in the area(s) they are assigned. To assign an area(s) to a User Access Code, enter the number corresponding to the area you wish to assign (i.e. [1] = area 1, ...[4] = area 4).
Press the [T] button to return to the User Options; press the [S] button to proceed to step 8; or press the [ENTER] button to save and exit programming mode.

A) Enter the 2-digit Access Level (i.e. 00, 01,...15) within the first set of brackets.
An Access Level determines which Access Control Doors a User is allowed to pass through. There are 16 possible Access Levels which are usually programmed by your Installer. Access to all Access Control Doors is Access Level 00.
B) Enter the 2-digit Schedule (i.e. 00, 01,...15) in the second set of brackets.
Schedules, programmed by your Installer, determine the hours, days, and holidays that Users are permitted through Access Control Doors. Each user is assigned a Schedule through the User Access Code. To provide access at all times, assign Schedule 00.

Program the Access Control User Options by pressing the number on your keypad that corresponds to the Option you wish to assign. The option is considered ON when the number appears within the brackets. For a detailed description of the User Access Control Options, refer to section 5.5 on page 11. Press the [S] button to proceed to step 10.
Option [1]: Access Card is Activated Option [2]: Can Disarm with Access Card Option [3] : Extended Unlocked Period Options [4], [5], [6] & [7]: Arming with Card Option [4] OFF = Disable the Arming with Card feature Option [4] ON, options [5], [6] & [7] OFF = Regular Arm Options [4] & [5] ON, options [6] & [7] OFF = Stay Arm Options [4] & [6] ON, options [5] & [7] OFF = Instant Arm Options [4] & [7] ON, options [5] & [6] OFF = Force Arm Option [8]: Access to Armed Access Control Doors

Enter the Access Control Card’s serial number within the brackets.
Press the [ENTER] button to save and exit.

Options [1] and [2]: Master Feature When option [1] is OFF, the User cannot program other Users into the system. When option [1] is ON and option [2] is OFF, the User can only modify existing User Access Codes. When both options [1] and [2] are ON, the User has Full Master rights. The User can create or modify User Access Codes, User Options, User Access Control Options, Access Card Numbers and Area Assignments according to their own programming. For example, if the Full Master User has access to area #1 and option [4] (Bypass) only, the Full Master User can only assign area #1 and option [4] to other Users in the system.
Option [3]: Duress When option [3] is ON, the Duress feature is enabled. This feature is used when someone forces a User to arm or disarm an area(s). By entering a User Access Code (P.I.N.) reserved for the Duress feature, the system will arm or disarm the area(s), and then send a silent alarm to the Central Monitoring Station.
Option [4]: Bypass When option [4] is ON, the Bypass feature is enabled. This feature allows the User to deactivate zones when arming the area(s).
Option [5]: Arm Only When option [5] is ON, the Arm Only feature is enabled. The User can arm assigned areas with either a card or code, but cannot disarm. When the option is OFF, the User can either arm or disarm assigned areas.
Option [6]: Stay & Instant Arm When option [6] is ON, the Stay and Instant Arm features are enabled. The User can now Stay or Instant Arm their assigned areas.
Option [7]: Force Arm When option [7] is ON, the Force arm feature is enabled. The User can now Force arm their assigned areas.
Option [8]: Area Access When option [8] is ON, the keypad will permit access to all the areas assigned to the User Access Code. When option [8] is OFF, the keypad will only permit access to the areas it controls. For example, the keypad is assigned area 1 only, and your User Access Code is assigned areas 1 to 4. If the option is ON, you can access all four areas from the keypad. If the option is OFF, you can only access area 1.
By default all Users can Regular arm the system.
Option [1]: Access Card is Activated When option [1] is ON, the Access Control Card is activated and can be used when Access Control is enabled in the system. When the option is OFF, the Access Control Card cannot be used.
Option [2]: Disarming with Access Card When option [2] is ON, a User’s Access Control Card can unlock and disarm an armed Access Control Door (see section 6.2.2 on page 12).
For option [2] to function in the ON position, option [5] “Arm Only” in the User Options must be disabled (refer to section 5.4 on page 11).
Option [3]: Card with Extended Unlocked Period When option [3] is ON, “Extended Unlocked Period” is enabled. “Extended Unlocked Period” refers to the time period programmed into each Access Control Door by your Installer that extends the unlocked time of the door. For example, if your Installer sets the Unlocked period of the door to 30 seconds and the Extended Unlocked Period to 15 seconds, then a User Access Code with “Extended Unlocked Period” enabled will have a total of 45 seconds to pass through the door.
Options [4] to [7]: Arming with Card Options [4] to [7] define the type of arming when arming with an Access Control Card (refer to section 6.2.1 on page 12). You can either Regular arm, Stay arm, Instant arm, or Force arm.
[4] ON, [5] to [7] OFF = Regular Arm [4] & [5] ON, [6] & [7] OFF = Stay Arm [4] & [6] ON, [5] & [7] OFF = Instant Arm [4] & [7] ON, [5] & [6] OFF = Force Arm

Option [8]: Access to Armed Access Control Doors When option [8] is enabled, the Access Control Card can be used to open an armed Access Control Door. When a valid Access Control Card is presented to a reader that is assigned to a zone and the zone is armed, access will be granted and the Entry Delay will begin. When option [8] is ON, extra security is provided since a user must enter a User Access Code to disarm the area.
For option [8] to function in the ON position, option [5] “Arm Only” in the User Options (refer to section 5.4 on page 11) and option [2] “ Disarming with Access Card” in the Access Control User Options (refer to section 5.5 on page 11) must be disabled.
6.1 ENTERING & EXITING Depending on how your system is installed, there are various ways to enter and exit Access Control Doors:

6.2.1 ARMING WITH CARD An Access Control Card can be programmed to arm areas assigned to the door when it is presented to the reader (door) twice within approximately 5 seconds without opening the door. The Access Control card must be:
6.2.2 DISARMING WITH CARD To disarm and unlock an Access Control Door when the area assigned to it is armed, present your Access Control Card to the reader (door).
The Access Control card must be:

6.3 HOW ACCESS CONTROL WORKS To illustrate how Access Control functions, we will use three simple Access Control System examples:
Figure 6.1: Example A Bonnie’s Access Control Card is programmed with Access Level 01 and Schedule 01. If she presents her card to the reader on Door 02 on Tuesday, August 3 at 3 p.m., she will gain access to the room.

Figure 6.2: Example B If Bonnie presents her card to the reader on Door 02 on Saturday or on a Holiday at 3 p.m., she will be denied access.

Figure 6.3: Example C If we change Bonnie’s Access Level to 02 and she presents her card to the reader on Door 02 on Tuesday, August 3 at 3 p.m., she will be denied access.


If your system experiences any problems, “Trouble(s) [TRBL] to View” will appear on the LCD screen. The Trouble Display will only display the troubles that occur in the area(s) to which the keypad has been assigned. Potential troubles have been sorted into eight groups. Only the troubles which are relevant to you are listed and described below. If a trouble that is not described or listed below appears, contact your Installer.
To View the Trouble Display:
We strongly suggest that if any troubles occur, contact your Installer immediately to have your system serviced.
7.0.1 GROUP 1: SYSTEM AC Failure The control panel has detected a power failure. This means that your system is running on the backup battery. If this trouble occurs when your establishment is not experiencing a power failure, call your Installer for repairs.
Battery Trouble The backup battery is disconnected, needs to be recharged, or replaced.
Bell Absent The system has detected that the bell or siren is not connected.
7.0.2 GROUP 5: ZONE TAMPER The zone(s) that was tampered with will be displayed on the LCD screen.
7.0.3 GROUP 6: ZONE LOW BATTERY If a wireless device's battery needs to be replaced, the zone that is assigned to the device will be displayed on the LCD screen.
7.0.4 GROUP 7: ZONE FAULT A wireless device is no longer communicating with its receiver, or a connection or CleanMeTM trouble is occurring with your smoke detectors.
7.0.5 GROUP 8: CLOCK LOSS The time and date have been reset to the default. This is the only trouble that we recommend that you correct. “Clock Loss [8] to Set” will appear on the LCD screen after you press the [TRBL] button. Refer to section 8.3 on page 15 to set the time and date.
7.1 EVENT RECORD DISPLAY The Event Record Display will record the user-initiated actions that occurred in your system as well as any alarms or troubles (i.e. “Access Granted”). You will only be able to view the events that occurred in the area(s) assigned to your User Access Code.
To view the Event Record:
Once you have entered Event Record Display mode, you can change the order that the Event Record screens appear by pressing the [7] button. If you already know the number of the event you want to view, press the [MEM] button after step 3 above, and then enter the event's number.

8.1 PROGRAMMABLE OUTPUTS (PGMS) Your system includes Programmable Outputs (PGMs) that can be programmed by your Installer. A PGM triggers when a predetermined event or series of events occurs in your system. The PGMs can be programmed to reset smoke alarms, turn on light switches, open or close garage doors and much more. Ask your Installer about this useful feature.
8.2 KEYPAD SETTINGS You can modify the keypad settings to suit your needs (Refer to Figure 8.1 on page 15).

8.3 SET TIME & DATE To Set the time and date:
1. Enter your [ACCESS CODE] and press the [TRBL] button. 2. Press the [8] button. 3. To change the time, place the cursor under the number you want to change by using the [S] button and enter the time according to a 24-hour clock (i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00). 4. To change the date, place the cursor under the number you want to change and enter the correct date accord- ing to year/month/day. 5. Press the [ENTER] button to save and exit.
8.4 PROGRAMMING CHIME ZONES You can program the keypad to emit a rapid, intermittent beep tone whenever designated zones are opened or only when opened between certain hours. These zones are referred to as Chime Zones. Your installer can also program your Chime zones to beep upon closure.

OR Press the [2] button to set the time period a chimed zone will beep. Enter the time that the chimed zone(s) will start beeping when opened (HH:MM). Enter the time that the chimed zone(s) will stop beeping when opened (HH:MM). 4. Press [CLEAR] to exit chime programming.
8.5 PANIC ALARMS Your system can be programmed to send an alarm to your Central Monitoring Station to request help from the police, a medical facility, the fire department, or anyone you wish when you press a pre-determined combination of buttons. To generate a panic alarm, simultaneously press and hold the button combinations displayed in Table 1 on page 16. Your installer can program the alarm to be either silent or audible.
Panic Alarm Types Buttons to be pressed and held
Emergency Panic Press & hold the [1] and [3] buttons
Auxiliary Panic Press & hold the [4] and [6] buttons
Fire Panic Press & hold the [7] and [9] buttons
8.6 QUICK FUNCTION BUTTONS You will only need to use the Quick Function Buttons upon your Installer’s or Central Monitoring Station's request. Only the System Master Code or User Access Codes with the Master feature enabled will be able to access these functions.
To access the Quick Functino Buttons:
9.1 BURGLAR ALARM TESTING Two people are needed to complete this test. One person will watch the LCD screen on the keypad while the other person walks around the protected areas and opens the zones (i.e. opens the doors and windows that are protected, walk in the path of the motion detectors, etc.). The LCD screen will display the opened zones, but if a zone does not register, contact your Installer.
9.2 FIRE ALARM TESTING Do NOT use an open flame or burning materials to test your fire detection devices. Your Installer will provide details on the best way to test your system.
9.3 SYSTEM MAINTENANCE Under normal use your system requires no maintenance other than regular testing. We recommend that your Installer change the battery every three years.
simultaneously

9.4 SYSTEM TEST Speak to your Installer before conducting a System Test since the system must be programmed to respond to the test instructions. It is normally recommended that you conduct the system test once a week, but contact your Installer for instructions concerning your particular system.
To conduct a system test:
10.1 STANDARD FIRE ZONE During a fire alarm, the bell/siren emits an intermittent sound (BEEP-BEEP-BEEP) until silenced or reset. If the zone is a Standard Fire Zone, your system can immediately send an alert to your Central Monitoring Station.
To disarm a false alarm:
The Fire Zone may reset itself once the problem has cleared. If it does not, simultaneously press and hold the [CLEAR] and [ENTER] buttons for two seconds.
10.2 DELAYED FIRE ZONE If the zone is a Delayed Fire Zone, there is an automatic delay before your system contacts your Central Monitoring Station. Refer to Figure 10.1 on page 18 to prevent unnecessary reporting of false alarms.
If the fire alarm is triggered accidentally:
If you are unable to cancel the false alarm, your system will send an alert. Call your Central Monitoring Station to advise them of the false alarm.
The Fire Zone may reset itself once the smoke has cleared. If it does not, simultaneously press and hold the [CLEAR] and [ENTER] buttons for two seconds or speak to your installer.


10.3 FIRE SAFETY TIPS How should you prepare in case of a fire in your home or business?
10.4 MINIMIZING HOME FIRE HAZARDS How can you avoid the three most common causes of fires at home?
10.5 HOME FIRE WARNING SYSTEM Household fires are especially dangerous at night. Fires produce smoke and deadly gases that can overcome occupants while they sleep. To warn against fire, smoke detectors should be installed outside each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements.
In case of a burglar alarm, leave the premises and call the police station from a safe place.


Congratulations on choosing the Paradox InTouch Voice-Assisted Arm/Disarm Module (APR3-ADM2). InTouch turns any touch-tone telephone into a keypad. With InTouch, you can now arm or disarm your Digiplex security system as well as activate or deactivate your InTouch’s output all from your telephone. Using detailed voice prompts to guide your way, the InTouch is as simple as picking up your telephone.
InTouch uses your Digiplex User Access Code to grant you access to your Digiplex Security System. The User Access Code entered on your Digiplex system keypad is the same you would use to enter on your telephone.
InTouch will now ask you to enter your Digiplex User Access Code.
If your Digiplex Security System is programmed to accept variable code lengths, you must press the [#] key after entering your User Access Code.
press the desired area’s number on your telephone. This will toggle the area’s arming state from armed to disarmed and vice versa (refer to section 16.0 on page 20).
on page 20).
14.1 WHEN ACCESSING YOUR INTOUCH If you are using an answering machine or service, call the InTouch, hang up after one ring, wait between 10 and 255 seconds (depending on how Intouch was programmed by your Installer), and then call the InTouch again to access it.
Voice-Assisted Arm/Disarm Module · Operating Instructions

Clear = [*] If you have made an error, press the [*] button on your telephone to clear the error and then re-enter the information.
Activate/Deactivate InTouch Output = [#], [0] To activate or deactivate the InTouch’s output, press the [#] button and then the [0] button on your telephone.
Hang Up = [#], [9] When you wish to hang up, press the [#] button and then the [9] button to immediately hang up. The InTouch will confirm the hang up with “Good-bye”.
If the hang-up feature is not used and if no action is performed after 2 minutes, the InTouch will hang up automatically.
Nelson has a Digiplex Security System and an InTouch hooked up at home. His security system has two areas. Both areas are presently armed and the InTouch’s output, which is hooked up to his garage door opener, is deactivated. Nelson is on his way home and wishes to disarm both areas and open his garage door. Nelson performs the following:
Nelson first dials the telephone number of the line to which the InTouch is connected to.
When the InTouch picks up, it will prompt Nelson with the following:
“Please enter your code.”
Nelson enters his User Access Code.
The InTouch then prompts Nelson with the following:
“Area 1 Armed” “Area 2 Armed” “Output is Deactivated” “To modify, enter Area number”
Nelson presses the [1] key on his telephone to disarm Area 1.
Your User Access Code must also have access to the areas to which the InTouch is assigned to.

The InTouch then prompts Nelson with the following:
“Area 1 Disarmed” “Area 2 Armed” “Output is Deactivated” “To modify, enter Area number”
Nelson presses the [2] key on his telephone to disarm Area 2.
The InTouch then prompts Nelson with the following:
“Area 1 Disarmed” “Area 2 Disarmed” “Output is Deactivated” “To modify, enter Area number”
Nelson then presses the [#] key and then the [0] key on his telephone to activate the output which in turn will activate the garage door.
The InTouch then prompts Nelson with the following:
Nelson then presses the [#] key and then the [9] key on his telephone to terminate the call.
The InTouch then prompts Nelson with the following:
Output Timer Length: Nsec. or Nmin.
Call, hang-up, and then call back within sec.
Number of rings before InTouch answers:
“Output is Activated” · “Goodbye”

Warranty The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year (except as indicated otherwise). Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits, stolen goods, or claims by any other party caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold.