User’s Guide

PayClock, Lathem and the Lathem logo are registered trademarks of Lathem Time Corporation. Other product names mentioned in
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructional manual, may cause harmful interference to radio communications. Operation of this
Shielded cables must be used with this unit to ensure compliance with the Class A FCC limits
this manual may be trademarks of their respective companies and are hereby acknowledged.
authority to operate the equipment.
at his or her own expense.

Lathem warrants the hardware products described in this guide against defects in material and workmanship for a
period of one year from date of original purchase from Lathem or from an authorized Lathem reseller. The conditions
of this warranty and the extent of the responsibility of Lathem Time Corporation (“Lathem”) under this warranty are
deemed to have failed of its essential purpose, Lathem's maximum liability shall be to refund the purchase price
reseller and any such products are purchased "as is, with all faults." In no event will Lathem be liable for any
direct, indirect, special, incidental or consequential damages arising out of or in connection with the delivery,
had the serial number altered or removed, or which has been connected, installed, adjusted, or repaired other
the product must be shipped in its original carton or equivalent, fully insured with shipping charges prepaid.
use or inability to use, or performance of this product. In the event any limited remedy given herein shall be
set forth above, the products are sold with no expressed or implied warranties of any kind, and the implied
warranties are given with respect to products purchased other than from Lathem or an authorized Lathem
warranties of merchantability and fitness for a particular purpose are hereby expressly disclaimed. No
Lathem will not assume any responsibility for any loss or damage incurred in shipping.
Copyright © 2003 Lathem Time Corporation. All rights reserved.
Limited One-Year Limited Warranty
200 Selig Drive, SW, Atlanta, GA 30336 404-691-0405
authorized service centers, contact Lathem Time at the address below.
expendable parts that are readily replaced due to normal use.
than in accordance with instructions furnished by Lathem.
service dealer results in damage to the product.
thereof, at the sole discretion of Lathem.
upon return of the product.
product.
listed below.
Lathem Time · 08-04-2006




With the PC100 terminal, employees use their plastic ID badges to punch in and out –
it’s that simple. Using Lathem software and your computer, the PayClock terminal is
Reliability, functionality and ease of use are trademarks of the PayClock terminal.
the perfect solution for businesses that want to track employee time and automate
The PC100 terminal package includes the following:
payroll.

Check your package contents to make sure everything is accounted for before
starting. Decide where to mount your clock. Keep in mind that the AC adapter

» Insert each screw through the bracket into the anchors, and tighten
» Align the mounting bracket back on the wall
To mount the clock, you need the following items:
top (arrow pointing Up) is 54 inches from
» Insert an anchor into each hole, tapping it
with a hammer until it is flush against the
» Remove the bracket and drill a 5/16-inch
» Hold the bracket against the wall so the
» Mark the 3 holes with a pencil
hole at each mark
plugs into a wall outlet.
Drill with a 5/16” bit

» Turn your key counter-clockwise in the lock at the clock’s right-middle
» Align the keyholes on the back of the clock with the studs on the
» Turn the key clockwise to lock the clock onto the bracket
» Slide the clock down onto the bracket
» Remove the key
mounting bracket · section to unlock

terminals. The PC2500 modular port is set up to use with the PC400 terminals
When selecting your installation method, the type of wire that will be used is
using J-Kits or in areas where the cable may run near a device that transmits
PC100 / PC2000 modular port is set up to use with the PC2000 and PC100-R
computer. You can connect the PayClock terminal to the computer using an
RS-232 cable or RS-485 cable. Choose the setup that best suits your needs.
than 100’ to achieve communications. Category-3 or Category-5 cable with
twisted pairs should be used for distances greater than 100’, in installations
terminal blocks to connect the PC2000, PC100-R or PC3500 terminals. The
After mounting your PayClock on the wall, you need to connect it to your
The Swift-485+ allows you to connect PayClock terminals to the modular
(not currently available). The RS232 connection to the PC is made simple
ports and to the screw terminal blocks. You can use either of the screw
an RF frequency. Do not use J-Kits with modular wire
For details, see the Cable Wiring Diagrams appendix.
Connecting the PayClock via RS-232
Connecting Terminals via RS-485
using a stereo type plug in jack.

computer. You can wire the terminals directly to the SWIFT-485+ or use J-
kits (junction boxes). Terminals can be located up to 4000 feet from the
A star network connects up to 31 terminals or sync time devices to the


Connecting Terminals via RS-485 (Star Configuration)
connector on the end that plugs into the terminal
RS232

starting from the SWIFT-485+. Terminals can be located up to 4000 feet from
For more details or how to supply AC power to the PC100-R from the SWIFT-
A multi-drop network connects up to 31 terminals or sync time devices to the
computer. You wire the terminals to junction boxes running in a single line
Connecting Terminals via RS-485 (Multi-Drop Configuration)
Max 4000 ft from SWIFT-485+ to Last Terminal
SWIFT-485+ J-Kit (junction box)
Up to 31 Terminals
485+, see the SWIFT-485+ User’s Guide.
the computer

the left side of the badge when swiping. To swipe the badge, insert it at the top of
The PC100 has a magnetic stripe badge reader. The magnetic stripe should be on
This badge displays a clock status report. The status report shows the current
The base model PC100 clock allows only an RS-232 connection. The PC100-R
model allows RS-232 or RS-485 connections; RS-485 connections require the
Three supervisor badges are available for your PC100. These badges perform
MEM 10% | TIME 12HR
ID# 049 | BAUD 9600
| DST ON
the reader, and then pull it down with a continuous and smooth motion.

Badge #251 – View Clock Status
Terminal Manager software add-on.
certain tasks at the clock.
clock setup:

Swipe this badge to change the baud rate – the default is 9600. You may need
prompted, swipe an employee badge that matches your desired ID. If you
have more than one clock, make sure each one has a unique ID number.
1200 2400 4800 9600
prompted, swipe employee badge #1, 2, 4 or 9 to indicate 1200, 2400,
Swipe this badge to change the clock ID – the default ID is 49. When
To change the baud rate, swipe the Set Baud Rate badge, then when
♦ PC100 version number ♦ Terminal ID# (ID=49) ♦ Percent full memory (each time you poll the clock, this resets to 0%)
After a few seconds, the display returns to normal.
♦ Clock ready status (READY/LOAD LIST) ♦ Baud Rate ♦ 12-Hour or 24-Hour time display format ♦ Daylight Savings Time (DST) ON/OFF
problems communicating with the clock.
These problems can result from a noisy
Badge #254 – Setup Terminal ID
to reduce the baud rate if you have
environment or a long serial cable
Badge #253 – Set Baud Rate
(usually more than 50 feet).
4800 or 9600 baud.

Casing: 6.375”W x 7.375”H x 1.5”D flame-retardant ABS plastic. 19 oz. Includes key lock and wall mounting bracket
Swipe “Beeper” signals good or bad badge reading and low memory.
This product’s lithium battery contains Perchlorate Material –
www.dtsc.ca.gov/hazardouswaste/perchlorate for information
special handling may apply. Please go to web site
about proper methods of disposal in California.
of 2400, 4800 and 9600 baud. Up to 4000 feet
lithium battery.
Badge


A P P E N D I X A

Be sure to maintain polarity through out the chain
Fig. A – Junction box wiring connect points
instead of eight 8 points
See Fig. A
Some junction boxes have
only six connect points
PayClock PayClock PayClock · 6 points


correctly. See the section on Using the
This badge may have been exposed to
something magnetic. Replace this
Make sure you swiped the badge
badge with a new one
record and the clock does not signal
When I swipe a badge, it does not
A P P E N D I X B
Description Solution · Or · any errors




Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.