User’s Manual





2 - LT Series Operations Manual SPECIFICATIONS PHYSICAL Height: 7 inches Width: 5 1/4 inches Depth: 11 inches Weight: 12 3/4 pounds (standard models) 14 pounds (numbering models) Case: Impact Resistant Reinforced Lexan Color: Cool Gray Power Cord Length: 6 Feet COMPONENTS Print Wheels: Engraved Brass or Cast Zinc Alloy Printing Platen Assembly: Textured, soft surface for single copies. Ribbon: Purple Silk Fuse: 3 Amp. Digital Display: LED Timing Motor: 1 RPM, K342 type Ribbon Drive Motor: 21 RPM, Model 60-3 Transformer: 12 VAC, 50/60 Hz 117 VAC (50/60 Hz 230 VAC Optional) Numbering Solenoid: 110/120 VAC (220 VAC Optional) Print Solenoid: 110/120 VAC (220 VAC Optional) FEATURES Print Impact Adjustment: Variable, for multi-part forms Time Format: 12-hour AM/PM 24-hour Continental Optional POWER REQUIREMENTS Voltage: 110/120 VAC (220 VAC Optional) Current: 9 Amp. Max. Intrm. 110/120 VAC 4 1/2 Amp. Max. Intrm. 220 VAC Frequency: 60 Hz (50 Hz Optional) POSSIBLE SHOCK HAZARD EXISTS WHEN CASE COVER IS REMOVED AND AC POWER IS CONNECTED. USE CAUTION WHEN SETTING TYPE SECTION.

3 - LT Series Operations Manual INTRODUCTION The Lathem LT Series time stamps are considered "standard" by thousands of businesses and institutions because of their low initial cost and years of proven, trouble-free operation. The LT Series offers a wide variety of registration combinations that may be used for timing, numbering, and dating functions. The LT Series consists of four models, and is designed to meet virtually all of your validating needs. Standard features include: automatic registration; motor-driven ribbon shift for smooth, quiet operation; easy ribbon changing; registration position adjustment; and registration impact pressure control. Available options include a digital display, a manual registration button; allowing automatic or manual action, as well as repeat and advance numbering. All units carry a full one-year factory warranty.



Lathem LT Series: Time, Date, and Numbering Stamps Please read all directions carefully before operating or maintaining your LT Series unit. This operations manual is designed to provide basic operating instructions. Minor maintenance and adjustments may also be performed easily and effectively by referring to these instructions. For service beyond the scope of this manual, contact the dealer from whom you purchased the equipment, or Lathem Time Corporation. Should it be necessary to return the unit, retain the original packing materials for shipping.

LTD Registers date, month, and year. Type wheels must be advanced manually. Year wheels carry ten (10) years.
LTN Registers consecutive numbers. Basic unit includes six (6) numbering wheels which advance automatically. Up to five additional numerical, letter, or code wheels may be purchased. The additional wheels must be advanced manually. (Note: The manual registration button is standard on this module.)
LTT(C) Registers time, date, month, and year. Type wheels advance automatically. Month and date wheels must be reset manually the first day of each month. Models with a "C" designation have the optional digital display.
LTTN(C) Registers time, date, month, and year, as well as consecutive numbering. The unit includes six (6) numbering wheels which advance automatically. Month and date type wheels must be reset manually the first day of each month. Models with a "C" designation have the optional digital display. (Note: The manual registration button is standard on this module.)
CONSECUTIVE/DUPLICATE COUNT Models LTN and LTTN can repeat the same number once, twice, three times or four times before automatically advancing. (For jumper/shunt selection, see page 9, "Consecutive / Duplicate Count.")
REPEAT/ADVANCE SWITCH Overrides automatic numbering advance to allow repeating the same number if desired, or advances to a higher number. (See page 8 for operating instructions.)
INSCRIPTION PLATES The die plates may be permanently fixed or removable. They can have up to 3 lines of 20 characters per line, or carry facsimile signatures. (Note: Removable die plates must be removed before opening top frame and reinstalled after closing top frame.)

24-HOUR FORMAT The digital display models (LTTC and LTTNC) can display 12-hour (standard), or 24-hour, also known as the Continental (0-23 hour), format, when specified at time of order. The time wheels can print 24-hour format for an added charge.
FIXED PAPER GUIDE Provides a fixed edge on the side of the time stamp to help the user make more accurate registrations.
ADJUSTABLE PAPER GUIDE Enables the user to position registrations more accurately on various paper sizes. Adjustments are made quickly and easily with the slide mechanism.
MANUAL REGISTRATION BUTTON [Standard on LTN and LTTN(C)] Enables the user to position the document and manually activate the imprint.
GETTING STARTED Getting started with the LT Series is easy. There are only a couple of fundamental decisions that must be made. 1. Plug the unit into the wall outlet. 2. Place the clock on top of the anti-skid rubber pad 3. Set the type section. 4. Set the digital clock (optional feature).
INSTALLATION The LT Series time stamp installs easily on any tabletop or flat surface. Determine whether you have a 110/120 VAC or 220 VAC unit, then plug it into any appropriate AC wall outlet. (Note: Avoid outlets with On/Off switches. These outlets may be accidentally turned off, causing an interruption of the timing action.)
REGISTRATION When forms are fully inserted into the stamp, an automatic trigger causes registration. If the optional manual registration button is installed, insert a form to the desired position by aligning the desired registration position with the print locators (Figure 1, Number 1) on the side of the case. When the form is aligned, press the manual registration button on the front of the unit (Figure 1, Number 2).


SETTING THE TYPE WHEELS As noted in the earlier sections LT SERIES MODELS and OPTIONAL FEATURES, the LT Series Models are available with a variety of date, time, and number wheels. You may set the applicable type wheels according to the following directions.


Models with a "C" affixed to their designation (LTTC and LTTNC) denote units featuring a digital display. This display is factory-set for use in the 12-hour AM/PM format or the 24-hour (Continental) format. The digital display should always be synchronized with the time type wheels. To set the digital display and synchronize the display with the time type wheels, do the following:

(Note: Interruptions in power lasting more than 3 to 5 seconds will cause the digital display to flash, indicating that it is necessary to reset the display.)

Print impact may be set to any desired level, from very hard to very light. The impact adjuster is located on the bottom of the unit. Using a small flat head screwdriver, turn the adjuster to the right to increase or left to decrease the impact. (Figure 4)

(Note: To extend the effective life-span of the unit, use the lightest adjustment possible, which still gives a legible imprint.)
REPEAT/ADVANCE OPERATION The Repeat/Advance switch (Figure 5), located on the back of the machine, allows you to control the numbering feature of the unit. The Repeat/Advance switch provides the option of numbering items consecutively, or with the same number. To utilize these options:


Units equipped with the numbering feature may be configured for Consecutive Count, advancing the number type wheel after each registration, Duplicate Count, advancing the number type wheel after every two registrations., Triplicate Count, advancing the number type wheel after every three registrations, or Quad Count, advancing the number type wheel after every four registrations. All units are shipped with the Consecutive Count mode enabled. Units having circuit board version “E” and above also support Triplicate and Quad numbering options. (See figure 6b).
To switch to Duplicate Count mode, disconnect the power. Locate and remove the Access Cover (Figure 4) using a Phillips-head screwdriver. The version of the Control Circuit installed is indicated on the product label, on the underside of the unit, as well as on the circuit board, itself. On version “D” circuit boards, the shunt is placed over 2 pins (Figure 6a). Remove the shunt and place it over just 1 pin. To return to the Consecutive mode, reverse the procedure. For units having circuit board version “E” and above, the DUP, TRIP, and QUAD numbering features are selected by positioning the shunt according to (Figure 6b).

Depending on the type of document being stamped, it may be necessary to change the registration position. This can be accomplished by moving the trigger assembly. The trigger assembly has a range of motion of about two (2) inches forward or backward. The trigger assembly tells the unit how far the document must be inserted before activating the stamp. The print locators on either side of the top cover (Page 5, Figure 1, Number 1) can help you center the registration point.
To adjust the registration position:


LT Series time stamps use a silk ribbon for long-lasting, high-quality imprints. To avoid damaging the unit, use only a #20-S ribbon.
To change the ribbon:


Each model of the LT Series comes equipped with a fuse. The fuse protects the unit from damage in case of a power surge or electrical overload. If too much power reaches the fuse, the fuse burns out, or is "blown," stopping operation of the unit and avoiding costly damage.
To change the fuse:






Lathem warrants the hardware products described in this guide against defects in material and workmanship for a period of one year from date of original purchase from Lathem or from an authorized Lathem reseller. The conditions of this warranty and the extent of the responsibility of Lathem Time Corporation (“Lathem”) under this warranty are listed below.
6. WARRANTY DISCLAIMER AND LIMITATION OF LIABILITY: Except only the limited express warranty set forth above, the products are sold with no expressed or implied warranties of any kind, and the implied warranties of merchantability and fitness for a particular purpose are hereby expressly disclaimed. No warranties are given with respect to products purchased other than from Lathem or an authorized Lathem reseller and any such products are purchased "as is, with all faults." In no event will Lathem be liable for any direct, indirect, special, incidental or consequential damages arising out of or in connection with the delivery, use or inability to use, or performance of this product. In the event any limited remedy given herein shall be deemed to have failed of its essential purpose, Lathem's maximum liability shall be to refund the purchase price upon return of the product.
Lathem Time 200 Selig Drive, SW, Atlanta, GA 30336 404-691-0405
Copyright © 2009 Lathem Time Corporation. All rights reserved.

Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.