Introductionp.7Clock Operationp.7About this Manualp.8Optional Accessoriesp.9Configuring the DDC Series Wall Clockp.10Setting the DIP Switches - DDC2 / DDC4 Seriesp.11DDC2p.11DDC4p.11DIP Switch Settingsp.12Configuring RS485 Communications - DDC2/4-RS Seriesp.13DDC2-RSp.13DDC4-RSp.13Battery Usage - DDC2 / DDC4 Seriesp.13DDC2/4-RS / DDC2/4-RS-24p.13Battery Installation - DDC2 / DDC4 Seriesp.14DDC2p.14DDC4p.14Power Cord Installation - DDC2/4-RSp.14DDC2-RSp.14DDC4-RSp.15Wiring Installation - DDC2/4-RS Seriesp.15Secondary Wiringp.15RS485 Wiringp.15DDC-TC Wiringp.15Replacing an Existing DDC4 Wall Clockp.16Board Layout Diagramp.16Mounting - DDC2 / DDC4 Seriesp.16Mounting to a Wallp.17DDC2p.17DDC4p.18Mounting to a Single Gang Boxp.18DDC2p.19DDC4p.19Double Mount - Wallp.20DDC2 (Double Mount - Wall)p.21DDC4 (Double Mount - Wall)p.21Double Mount - Ceilingp.22DDC2 (Double Mount - Ceiling)p.24DDC4 (Double Mount - Ceiling)p.25Setting the Timep.25Time Formatsp.2612 Hour Formatp.2624 Hour Formatp.26Appendix A - DDC2-RS / 4-RS Secondary Clock Wiring Diagramsp.27Stand-Alone (115VAC)p.273-Wire Synchronous (115VAC)p.273-Wire Synchronous (24VAC)p.283-Wire minute Impulse (59th Minute)p.293-Wire Minute Impulse (59th Minute With 12 Hour Correction)p.30Standard Electric Synchronousp.31Standard Electric AR-2A 2-Wire Dual Voltagep.32Standard Electric AR-2 2-Wire Dual Voltagep.33Synchronous Wiredp.34Simplex 59th Minute Dual Motorp.35Simplex 45th Minute Dual Motorp.36Edwards Dual Motorp.37Standard Electric AR-3 3-Wire Minute Impulsep.38National Synchronous Wiredp.39Stromberg Synchronous Wired (56th Minute)p.40Cincinnati D1p.41Cincinnati D6, Edwards 2406p.422-Wire Pulse Alternating (24VDC)p.43Electronic Codedp.44Straight Frequencyp.453-Wire Minute Impulse (58th Minute)p.463-Wire Minute Impulse (44th Minute)p.472-Wire Reverse Polarity Minute Impulse (59th Minute)p.48Appendix B - DDC2-RS-24 / DDC4-RS-24 Wiringp.50DDC2-RS-24 / DDC4-RS-24 Wiringp.50Appendix C - RS485 Wiring Diagramsp.52RS485 Data Formatp.52OMCII to DDC2-RS / 4-RSp.53LTR0 to DDC2-RS / 4-RSp.53LTR4 / 8-512 to DDC2-RS / 4-RSp.54Appendix D - DDC-TC Timer Control Panelp.56Wiringp.56Installationp.57Operationp.58As a Count Up Timerp.58As a Count Down Timerp.58Appendix E - LTR-GPS Satellite Receiver / Clock Synchronizerp.59Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clockp.61Appendix F - Specificationsp.62Appendix G - Warrantyp.63Limited One-Year Limited Warrantyp.63
Page 1 of the Lathem DDC4 user manual — Digital Display Wall Clock
Page 1 · click to enlarge
Page 1
Lathem DDC4 diagram (page 1)
Fig. 1

Digital Display Wall Clock

DDC2 / DDC4 Series

Installation &

User's Guide

Page 2 of the Lathem DDC4 user manual
Page 2 · click to enlarge
Page 2

OMNI:CHRON, mini:master, Lathem and the Lathem logo are registered trademarks of Lathem Time Corporation. Other product names mentioned in this manual may be trademarks of their respective companies and are hereby acknowledged. WARNING: Changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTICE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio TV technician for help.

This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.

Copyright © 2001 Lathem Time Corporation. All rights reserved.

200 Selig Drive, SW Atlanta, GA 30336

www.lathem.com

Document NumberUSG0028D

Lathem Time Corporation · Revised 11-19-2004

Page 3 of the Lathem DDC4 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

Introductionp.7Clock Operationp.7About this Manualp.8Optional Accessoriesp.9Configuring the DDC Series Wall Clockp.10Setting the DIP Switches - DDC2 / DDC4 Seriesp.11DDC2p.11DDC4p.11DIP Switch Settingsp.12Configuring RS485 Communications - DDC2/4-RS Seriesp.13DDC2-RSp.13DDC4-RSp.13Battery Usage - DDC2 / DDC4 Seriesp.13DDC2/4-RS / DDC2/4-RS-24p.13Battery Installation - DDC2 / DDC4 Seriesp.14DDC2p.14DDC4p.14Power Cord Installation - DDC2/4-RSp.14DDC2-RSp.14DDC4-RSp.15Wiring Installation - DDC2/4-RS Seriesp.15Secondary Wiringp.15RS485 Wiringp.15DDC-TC Wiringp.15Replacing an Existing DDC4 Wall Clockp.16Board Layout Diagramp.16Mounting - DDC2 / DDC4 Seriesp.16Mounting to a Wallp.17DDC2p.17DDC4p.18Mounting to a Single Gang Boxp.18DDC2p.19DDC4p.19Double Mount - Wallp.20DDC2 (Double Mount - Wall)p.21DDC4 (Double Mount - Wall)p.21Double Mount - Ceilingp.22DDC2 (Double Mount - Ceiling)p.24DDC4 (Double Mount - Ceiling)p.25Setting the Timep.25Time Formatsp.2612 Hour Formatp.2624 Hour Formatp.26Appendix A - DDC2-RS / 4-RS Secondary Clock Wiring Diagramsp.27Stand-Alone (115VAC)p.273-Wire Synchronous (115VAC)p.273-Wire Synchronous (24VAC)p.283-Wire minute Impulse (59th Minute)p.293-Wire Minute Impulse (59th Minute With 12 Hour Correction)p.30Standard Electric Synchronousp.31Standard Electric AR-2A 2-Wire Dual Voltagep.32Standard Electric AR-2 2-Wire Dual Voltagep.33Synchronous Wiredp.34Simplex 59th Minute Dual Motorp.35Simplex 45th Minute Dual Motorp.36Edwards Dual Motorp.37Standard Electric AR-3 3-Wire Minute Impulsep.38National Synchronous Wiredp.39Stromberg Synchronous Wired (56th Minute)p.40Cincinnati D1p.41Cincinnati D6, Edwards 2406p.422-Wire Pulse Alternating (24VDC)p.43Electronic Codedp.44Straight Frequencyp.453-Wire Minute Impulse (58th Minute)p.463-Wire Minute Impulse (44th Minute)p.472-Wire Reverse Polarity Minute Impulse (59th Minute)p.48Appendix B - DDC2-RS-24 / DDC4-RS-24 Wiringp.50DDC2-RS-24 / DDC4-RS-24 Wiringp.50Appendix C - RS485 Wiring Diagramsp.52RS485 Data Formatp.52OMCII to DDC2-RS / 4-RSp.53LTR0 to DDC2-RS / 4-RSp.53LTR4 / 8-512 to DDC2-RS / 4-RSp.54Appendix D - DDC-TC Timer Control Panelp.56Wiringp.56Installationp.57Operationp.58As a Count Up Timerp.58As a Count Down Timerp.58Appendix E - LTR-GPS Satellite Receiver / Clock Synchronizerp.59Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clockp.61Appendix F - Specificationsp.62Appendix G - Warrantyp.63Limited One-Year Limited Warrantyp.63
Page 4 of the Lathem DDC4 user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

Introductionp.7Clock Operationp.7About this Manualp.8Optional Accessoriesp.9Configuring the DDC Series Wall Clockp.10Setting the DIP Switches - DDC2 / DDC4 Seriesp.11DDC2p.11DDC4p.11DIP Switch Settingsp.12Configuring RS485 Communications - DDC2/4-RS Seriesp.13DDC2-RSp.13DDC4-RSp.13Battery Usage - DDC2 / DDC4 Seriesp.13DDC2/4-RS / DDC2/4-RS-24p.13Battery Installation - DDC2 / DDC4 Seriesp.14DDC2p.14DDC4p.14Power Cord Installation - DDC2/4-RSp.14DDC2-RSp.14DDC4-RSp.15Wiring Installation - DDC2/4-RS Seriesp.15Secondary Wiringp.15RS485 Wiringp.15DDC-TC Wiringp.15Replacing an Existing DDC4 Wall Clockp.16Board Layout Diagramp.16Mounting - DDC2 / DDC4 Seriesp.16Mounting to a Wallp.17DDC2p.17DDC4p.18Mounting to a Single Gang Boxp.18DDC2p.19DDC4p.19Double Mount - Wallp.20DDC2 (Double Mount - Wall)p.21DDC4 (Double Mount - Wall)p.21Double Mount - Ceilingp.22DDC2 (Double Mount - Ceiling)p.24DDC4 (Double Mount - Ceiling)p.25Setting the Timep.25Time Formatsp.2612 Hour Formatp.2624 Hour Formatp.26Appendix A - DDC2-RS / 4-RS Secondary Clock Wiring Diagramsp.27Stand-Alone (115VAC)p.273-Wire Synchronous (115VAC)p.273-Wire Synchronous (24VAC)p.283-Wire minute Impulse (59th Minute)p.293-Wire Minute Impulse (59th Minute With 12 Hour Correction)p.30Standard Electric Synchronousp.31Standard Electric AR-2A 2-Wire Dual Voltagep.32Standard Electric AR-2 2-Wire Dual Voltagep.33Synchronous Wiredp.34Simplex 59th Minute Dual Motorp.35Simplex 45th Minute Dual Motorp.36Edwards Dual Motorp.37Standard Electric AR-3 3-Wire Minute Impulsep.38National Synchronous Wiredp.39Stromberg Synchronous Wired (56th Minute)p.40Cincinnati D1p.41Cincinnati D6, Edwards 2406p.422-Wire Pulse Alternating (24VDC)p.43Electronic Codedp.44Straight Frequencyp.453-Wire Minute Impulse (58th Minute)p.463-Wire Minute Impulse (44th Minute)p.472-Wire Reverse Polarity Minute Impulse (59th Minute)p.48Appendix B - DDC2-RS-24 / DDC4-RS-24 Wiringp.50DDC2-RS-24 / DDC4-RS-24 Wiringp.50Appendix C - RS485 Wiring Diagramsp.52RS485 Data Formatp.52OMCII to DDC2-RS / 4-RSp.53LTR0 to DDC2-RS / 4-RSp.53LTR4 / 8-512 to DDC2-RS / 4-RSp.54Appendix D - DDC-TC Timer Control Panelp.56Wiringp.56Installationp.57Operationp.58As a Count Up Timerp.58As a Count Down Timerp.58Appendix E - LTR-GPS Satellite Receiver / Clock Synchronizerp.59Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clockp.61Appendix F - Specificationsp.62Appendix G - Warrantyp.63Limited One-Year Limited Warrantyp.63
Page 5 of the Lathem DDC4 user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

Introductionp.7Clock Operationp.7About this Manualp.8Optional Accessoriesp.9Configuring the DDC Series Wall Clockp.10Setting the DIP Switches - DDC2 / DDC4 Seriesp.11DDC2p.11DDC4p.11DIP Switch Settingsp.12Configuring RS485 Communications - DDC2/4-RS Seriesp.13DDC2-RSp.13DDC4-RSp.13Battery Usage - DDC2 / DDC4 Seriesp.13DDC2/4-RS / DDC2/4-RS-24p.13Battery Installation - DDC2 / DDC4 Seriesp.14DDC2p.14DDC4p.14Power Cord Installation - DDC2/4-RSp.14DDC2-RSp.14DDC4-RSp.15Wiring Installation - DDC2/4-RS Seriesp.15Secondary Wiringp.15RS485 Wiringp.15DDC-TC Wiringp.15Replacing an Existing DDC4 Wall Clockp.16Board Layout Diagramp.16Mounting - DDC2 / DDC4 Seriesp.16Mounting to a Wallp.17DDC2p.17DDC4p.18Mounting to a Single Gang Boxp.18DDC2p.19DDC4p.19Double Mount - Wallp.20DDC2 (Double Mount - Wall)p.21DDC4 (Double Mount - Wall)p.21Double Mount - Ceilingp.22DDC2 (Double Mount - Ceiling)p.24DDC4 (Double Mount - Ceiling)p.25Setting the Timep.25Time Formatsp.2612 Hour Formatp.2624 Hour Formatp.26Appendix A - DDC2-RS / 4-RS Secondary Clock Wiring Diagramsp.27Stand-Alone (115VAC)p.273-Wire Synchronous (115VAC)p.273-Wire Synchronous (24VAC)p.283-Wire minute Impulse (59th Minute)p.293-Wire Minute Impulse (59th Minute With 12 Hour Correction)p.30Standard Electric Synchronousp.31Standard Electric AR-2A 2-Wire Dual Voltagep.32Standard Electric AR-2 2-Wire Dual Voltagep.33Synchronous Wiredp.34Simplex 59th Minute Dual Motorp.35Simplex 45th Minute Dual Motorp.36Edwards Dual Motorp.37Standard Electric AR-3 3-Wire Minute Impulsep.38National Synchronous Wiredp.39Stromberg Synchronous Wired (56th Minute)p.40Cincinnati D1p.41Cincinnati D6, Edwards 2406p.422-Wire Pulse Alternating (24VDC)p.43Electronic Codedp.44Straight Frequencyp.453-Wire Minute Impulse (58th Minute)p.463-Wire Minute Impulse (44th Minute)p.472-Wire Reverse Polarity Minute Impulse (59th Minute)p.48Appendix B - DDC2-RS-24 / DDC4-RS-24 Wiringp.50DDC2-RS-24 / DDC4-RS-24 Wiringp.50Appendix C - RS485 Wiring Diagramsp.52RS485 Data Formatp.52OMCII to DDC2-RS / 4-RSp.53LTR0 to DDC2-RS / 4-RSp.53LTR4 / 8-512 to DDC2-RS / 4-RSp.54Appendix D - DDC-TC Timer Control Panelp.56Wiringp.56Installationp.57Operationp.58As a Count Up Timerp.58As a Count Down Timerp.58Appendix E - LTR-GPS Satellite Receiver / Clock Synchronizerp.59Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clockp.61Appendix F - Specificationsp.62Appendix G - Warrantyp.63Limited One-Year Limited Warrantyp.63
Page 6 of the Lathem DDC4 user manual
Page 6 · click to enlarge
Page 6
Page 6 of the Lathem DDC4 user manual
Page 7 of the Lathem DDC4 user manual — Clock Operation
Page 7 · click to enlarge
Page 7

Page 1 Digital Display Wall Clock Guide

Introduction

The Digital Display Series Wall Clocks are designed with 2-inch or 4-inch red LED displays that can be viewed from great distances; the 4-inch model as far away as 100 feet, the 2-inch model from as far away as 50 feet. The bright red display shows the hour and minutes and can be configured for a 12 or 24 hour format. By the setting of internal DIP switches, the DDC Series Wall Clocks can be configured to run as "stand-alone" or to replace many analog secondary clocks that may be hard to find or no longer available. The DDC Series Wall Clocks can be synchronized from the Lathem LTR4-512 or LTR8-512 Master, LTR0 mini:master, Terminal Manager Software or the OMNI:CHRON Time Clock, using an RS485 correction signal. The DDC Series Wall Clocks with the optional DDC-TC Timer Control Panel allow the DDC Series Wall Clocks to act as a count up or count down timer as well as displaying the normal time. The optional Timer Control Panel is required to use this feature. The DDC Series Wall Clocks can be mounted directly to a wall, to a single gang outlet box or, with optional mounting kits, as double-faced units from the wall or ceiling. During power failures, a 9-Volt alkaline battery (not supplied) can maintain the DDC Series Wall Clock's internal time keeping (although the display is blank during power failures).

Clock Operation

When the Digital Display Series Wall Clocks are set to operate as stand-alone or synchronous wired secondary clocks, the time base is derived from the AC power source. The frequency (50Hz or 60Hz) is automatically detected when power is applied. The clocks then initialize to 12:00AM and maintain time by counting the line frequency. Corrective clocks will begin synchronization routines. Accuracy is related directly to the accuracy of the line frequency. With the DDC-TC option, the Digital Display Series Wall Clocks can act as a count up or count down timer as well as running as a stand-alone or synchronous wired secondary clock. When the Digital Display Series Wall Clocks are set to operate as impulse secondary clocks, the master clock controls time totally. Time will only advance when pulses are received from the master clock. Should the master clock lose power, the wall clocks would hold at the time that the last pulse was received until power to the master clock is restored and pulses continue. With the DDC-TC option, the Digital Display Series Wall Clocks can act as a count up or count down timer as well as running as an impulse secondary clock.

Page 8 of the Lathem DDC4 user manual — About this Manual
Page 8 · click to enlarge
Page 8

Digital Display Wall Clock Guide Page 2

About this Manual

This manual will guide you through the installation, setup and wiring of your DDC Series Wall Clock. This manual covers the four available DDC Series models. The available models and their descriptions are: DDC2-RS / DDC4-RS Equipped with a 2-inch or 4-inch display, these models can operate as a stand- alone, a secondary clock to virtually any master controlled system or can be synchronized with the RS485 signal from the Lathem LTR4-512 or LTR8-512 Master, LTR0 mini:master, Terminal Manager Software* or the OMNI:CHRON Time Clock. DDC2-RS-24 / DDC4-RS-24 Same as above, models with the "-24" suffix have an optional power transformer that allows for 24VAC operation. These models are designed to be powered from an external, 24VAC-power supply for use in installations where local 115VAC power may not available.

* The Lathem SWIFT-485 plus is required for RS485 synchronization.

Page 9 of the Lathem DDC4 user manual — Optional Accessories
Page 9 · click to enlarge
Page 9

Page 3 Digital Display Wall Clock Guide

Optional Accessories

VSE0050 Power Cord, 6 feet. DDC Series Wall Clocks are shipped without power cords. SAM0626 Double Ceiling Mount Kit for DDC2 or DDC4 Series SAM0630 Double Wall Mount Kit for DDC2 Series SAM0625 Double Wall Mount Kit for DDC4 Series VSE0052 Mounting Bracket for 3510 Hz Electronic Receiver. (DDC4 only, installer must use optional method to mount Receiver outside the DDC2 if Receiver is used) (Receiver not included) DDC-TC Timer Control Panel to use the DDC2/4 Series as a count up/down timer LTR4-512 LTR8-512 LTR8-512M Master Clocks capable of synchronizing the DDC Series Wall Clocks as well as many other brands and types of wall clocks. Available configurations include 8, 6, 4 and 2 bell circuits Mlink Master Link software for remote programming of the LTR8-512 and LTR8- 512M Master Clocks SWIFT-485 plus RS232 to RS485 signal converter for use with Master Link to extend the distance of Master Clocks up to 4000'.

Page 10 of the Lathem DDC4 user manual — Configuring the DDC Series Wall Clock
Page 10 · click to enlarge
Page 10

Digital Display Wall Clock Guide Page 4

SAM0626 Kit (left) Includes: 1 - Mounting Plate Assembly 2 - Chase Nipples 4 - #10 Screws 8 - #10 Lock Washers 8 - #10 Hex Nuts

SAM0630 Kit (middle) Includes: 1 - Mounting Plate Assembly 2 - Modified End Caps 2 - Chase Nipples 4 - #10 Screws 8 - #10 Lock Washers 4 - #10 Hex Nuts

SAM0625 Kit (right) Includes: 1 - Mounting Plate Assembly 2 - Modified End Caps 1 - End Cap Support 2 - Chase Nipples 4 - #10 Screws 8 - #10 Lock Washers 4 - #10 Hex Nuts 4 - #6 Screws

4. #6 Lock Washers 4 - #6 Hex Nuts
Page 11 of the Lathem DDC4 user manual — Setting the DIP Switches - DDC2 / DDC4 Series
Page 11 · click to enlarge
Page 11

Page 5 Digital Display Wall Clock Guide

Configuring the DDC Series Wall Clock

Setting the DIP Switches - DDC2 / DDC4 Series

DDC2 Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and circuit board assembly out of the case. Place the lens aside and carefully flip the circuit board assembly over and lay it face down on a clean, smooth work surface. Locate switch S1near the center of the circuit board and set the DIP switches (See figure1below) according to Tables 1, 2 and 3 on the following page for the proper configuration. Slide the lens and circuit board assembly back into the case, replace the end cap and secure with the four phillips head screws.

DDC4 Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel assembly out of the case. Carefully flip the front panel assembly over and lay it face down on a clean, smooth work surface. Locate switch S1near the center of the circuit board and set the DIP switches (See figure1below) according to Tables 1, 2 and 3 on the following page for the proper configuration. Slide the front panel display back into the case, replace the end cap and secure with the two phillips head screws.

1 2 3 4 5 6 7 8

Switch 8 12 or 24 Hour Format Default Shown - 12 Hour

Switches 1 - 5 Secondary Clock Type Default Shown - Stand Alone

Switches 6 & 7

Baud Rate Default Shown - 9600 Baud

= Depressed Side of Switch

Switch S1

Page 12 of the Lathem DDC4 user manual — DIP Switch Settings
Page 12 · click to enlarge
Page 12

Digital Display Wall Clock Guide Page 6

DIP Switch Settings

00000Stand Alone * 100003-Wire Synchronous 010003-Wire Minute Impulse (59th Minute) 110003-Wire Minute Impulse (59th Minute) With 12 Hour Correction 00100Standard Electric Synchronous 10100Standard Electric AR-2A - 2-Wire Dual Voltage 01100Standard Electric AR-2 - 2-Wire Dual Voltage 11100Cincinnati D8, Honeywell ST402A, Faraday Synchronous 00010Simplex 59th Minute Dual Motor 10010Simplex 45th Minute Dual Motor 01010Edwards Dual Motor 11010Standard Electric AR-3 - 3-Wire Minute Impulse 00110National Synchronous Wired 10110Stromberg Synchronous Wired 01110Cincinnati D1 10001Cincinnati D6, Edwards 2406 010012-Wire Impulse Alternating (24VDC) 11001Electronic Coded (3510 Hz Receiver Required) 00101Straight Frequency (3510 Hz Receiver Required) 101013-Wire Minute Impulse (58th Minute) 011013-Wire Minute Impulse (44th Minute) 111012-Wire Reverse Polarity Minute Impulse (59th Minute)
001200 Baud 102400 Baud 014800 Baud 119600 Baud *
112 Hour * 024 Hour
Page 13 of the Lathem DDC4 user manual — Battery Usage - DDC2 / DDC4 Series
Page 13 · click to enlarge
Page 13

Page 7 Digital Display Wall Clock Guide

Configuring RS485 Communications - DDC2/4-RS Series

When multiple DDC2 (4)-RS Series Wall Clocks are installed as slave units to either the Lathem LTR4- 512 or LTR8-512 Master, LTR0 Mini-Master, Terminal Manager Software or the OMNI:CHRON Time Clock, the last clock on the line must have a shunt installed over both pins at position J2 (see figure 2, page 9). When shipped, the shunt is placed over only one pin of position J2 in an "open" setting. It is necessary to place the shunt over both pins of position J2 and create a "closed" setting for the last clock on the line.

DDC2-RS Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and circuit board assembly out of the case. Place the lens aside and carefully flip the circuit board assembly over and lay it face down on a clean, smooth work surface. Locate position J2 on the left, upper side of the back of the circuit board assembly (see figure 2, page 9). Lift the shunt straight up off the single pin of position J2. Align the shunt to cover both pins of position J2 and press firmly into place. Slide the lens and circuit board assembly back into the case, replace the end cap, and secure with the four phillips head screws.

DDC4-RS Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel assembly out of the case. Carefully flip the front panel assembly over and lay it face down on a clean, smooth work surface. Locate position J2 on the left, upper side of the back of the front panel. (See figure 2, page 9) Lift the shunt straight up off the single pin of position J2. Align the shunt to cover both pins of position J2 and press firmly into place. Slide the front panel display back into the case, replace the end cap and secure with the two phillips head screws. Note: Only the LAST clock on the line needs position J2 "closed". Leave all other clocks "open".

Battery Usage - DDC2 / DDC4 Series

Depending on the secondary selection type, the 9-Volt alkaline battery (not included) performs different functions and may be required for proper operation.

DDC2/4-RS / DDC2/4-RS-24 When used as a secondary type clock the 9-Volt alkaline battery (not included) will retain the time that the power failure occurred, although the display will go blank. When power is restored, correction signals from the master clock will advance the wall clock to the proper time. When used as a secondary type clock in systems that do not provide a 12-Hour correction signal, the 9-Volt alkaline battery (not included) is required for proper operation. Without the 9-Volt alkaline battery (not included), the wall clock will reset to 12:00 AM after power resumes and will not receive the proper signal from the master clock to fully correct.

Page 14 of the Lathem DDC4 user manual — Power Cord Installation - DDC2/4-RS
Page 14 · click to enlarge
Page 14

Digital Display Wall Clock Guide Page 8

When used as a RS485 clock, the master clock will send a signal to the wall clock every minute. The 9- Volt alkaline battery (not included) is optional in these types of installations.

Battery Installation - DDC2 / DDC4 Series

DDC2 Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and circuit board assembly out of the case. Place the lens aside and carefully flip the circuit board assembly over and lay it face down on a clean, smooth work surface. Locate the Battery Cradle on the upper right corner of the circuit board assembly. (See figure 2, page 9) Slide the battery into the cradle making sure the Positive and Negative connections of the battery and cradle match. Snap the battery onto the connections located inside the battery cradle. Slide the lens and circuit board assembly back into the case, replace the end cap and secure with the four phillips head screws.

DDC4 Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel assembly out of the case. Carefully flip the front panel assembly over and lay it face down on a clean, smooth work surface. Locate the Battery Cradle on the upper right corner of the circuit board assembly. (See figure 2, page 9) Slide the battery into the cradle making sure the Positive and Negative connections of the battery and cradle match. Snap the battery onto the connections located inside the battery cradle. Slide the front panel display back into the case, replace the end cap and secure with the two phillips head screws.

Power Cord Installation - DDC2/4-RS

DDC2-RS Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and circuit board assembly out of the case. Place the lens aside and carefully flip the circuit board assembly over and lay it face down on a clean, smooth work surface. Remove one of the vent caps from the case of the wall clock and route the power cord through it to the back of the circuit board assembly. (If the power cord will be routed through the back-of-the-clock conduit access, route the cord through the gang box and conduit access hole to the back of the circuit board assembly). Strip away 1/2" of the protective shield from each wire of the power cord. Locate the two black wires leading from J1 (see figure 2, page 9) and attach the AC In line of the cord to one and the AC Return line to the other. (normally black is AC In and white is

Page 15 of the Lathem DDC4 user manual — Wiring Installation - DDC2/4-RS Series
Page 15 · click to enlarge
Page 15

Page 9 Digital Display Wall Clock Guide

AC Return) Attach the ground wire of the cord (normally green) to the green ground screw located on the inside back of the case. Slide the lens and circuit board assembly back into the case, replace the end cap and secure with the four phillips head screws.

DDC4-RS Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel assembly out of the case. Carefully flip the front panel assembly over and lay it face down on a clean, smooth work surface. Remove one of the vent caps from the case of the wall clock and route the power cord through it to the back of the display panel. (If the power cord will be routed through the back-of-the- clock conduit access, route the cord through the gang box and conduit access hole to the back of the circuit board assembly). Strip away 1/2" of the protective shield from each wire of the power cord. Locate the two black wires leading from J1 (see figure 2, page 9) and attach the AC In line of the cord to one and the AC Return line to the other (normally black is AC In and white is AC Return). Attach the ground wire of the cord, (normally green) to the green ground screw located on the inside back of the case. Slide the front panel display back into the case, replace the end cap and secure with the two phillips head screws.

Wiring Installation - DDC2/4-RS Series

Secondary Wiring The DDC Wall Clock comes with a detachable wiring harness to make installation easier. The wiring harness can be removed from the back of the main circuit board at position J1 as shown in figure 2 so wiring from the master clock can be attached to the wiring harness with the clock's Electronic Assembly removed. The leads from the wiring harness should be connected as shown in the diagrams in Appendix A.

RS485 Wiring The DDC Wall Clock comes with a detachable wiring block to make installation easier. The wiring block can be removed from the back of the main circuit board at position JP4 as shown in figure 2 so wiring from the master clock can be attached without the need of holding the Wall Clock itself. Wiring should be connected as shown in the diagrams in Appendix C.

DDC-TC Wiring The DDC Wall Clock comes with a detachable wiring block to make installation easier. The wiring block can be removed from the back of the main circuit board at position JP2 as shown in figure 2 so wiring from the Timer Control Panel can be attached without the need of holding the Wall Clock itself. Wiring should be connected as shown in the diagrams in Appendix D.

Page 16 of the Lathem DDC4 user manual — JP4
Page 16 · click to enlarge
Page 16

Digital Display Wall Clock Guide Page 10

Replacing an Existing DDC4 Wall Clock When replacing an older style DDC4 Wall Clock it will be necessary to remove any connectors used by the older style clock and attach the wires to the new DDC Series Wall Clock as described above.

Board Layout Diagram

J2

9VDC Alkaline Battery Cradle

J1

S1

1 2 3 4 5 6 7 8

Lathem Time Corp. DDC2\4 (E-PROM)

JP4

JP3

JP1

J4

J3

J2 Install shunt on last clock for RS485 connections

Show 9 more labels / short text on this page
Fly Lead Connector · Jumper · DIP Switch · Hours Minutes Up · - + · JP2 Down · Ground Beeper D- D+ · J2 Factory Default · Off
Page 17 of the Lathem DDC4 user manual — Mounting - DDC2 / DDC4 Series
Page 17 · click to enlarge
Page 17

Page 11 Digital Display Wall Clock Guide

Mounting - DDC2 / DDC4 Series

The DDC Series Wall Clocks can be mounted directly to a wall, to a single gang outlet box, double hung from the wall or double hung from the ceiling. When deciding where the clock will be mounted, keep in mind that 115VAC power may be required depending on the installation type. See page 14, figure 3.

Mounting to a Wall Tools required for mounting the clock: Drill with a 5/16" bit Hammer Phillips head screwdriver Wall anchors Pencil

DDC2 » After deciding the location where the clock will be mounted, make two marks 7" apart and horizontal. Note: If mounting near a ceiling, make sure the holes are at least 2 1/4" away from the ceiling. Note: Make sure you have at least 10 1/2" of side clearance on one side in order to remove the lens and circuit board assembly. » Drill a 5/16" hole at each mark » Insert a wall anchor in each hole and tap it flush to the wall with the hammer. » Insert a screw into each wall anchor leaving 1/4" exposed. » Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and circuit board assembly out of the case and set aside. » Line up the two keyholes on the back of the case and slip over the two screws and tighten securely. ( The lower mounting holes can be marked at this point, the case removed, holes drilled and wall anchors installed if so desired) » Remove the desired vent cap that any required wiring will route through. (If the wiring will be installed through the back-of-the-clock conduit access, route the fly leads of the clock's Cable Harness Assembly from the interior of the clock through the hole in the Clock's rear plate. Use wire nuts or crimp connectors to join these leads with the power and synch signal cable in the gang box behind the clock to eliminate possible snagging when the circuit board assembly is removed or replaced. If RS-485 signaling is used, attach the signal pair to the mini Terminal Block Plug and pass the cable from behind the clock, through the hole into the clock's interior). » Route the 6-position plug (and optional RS485 cable) to the circuit board assembly and attach.

Page 18 of the Lathem DDC4 user manual — DDC4
Page 18 · click to enlarge
Page 18

Digital Display Wall Clock Guide Page 12

» Slide the lens and circuit board assembly back into the case, replace the end cap and secure with the four phillips head screws.

DDC4 » After deciding the location where the clock will be mounted, make two marks 12" apart and horizontal. Note: If mounting near a ceiling, make sure the holes are at least 2 1/4" away from the ceiling. Note: Make sure you have at least 16" of side clearance on one side in order to remove the front panel. » Drill a 5/16" hole at each mark » Insert a wall anchor and tap it flush to the wall with the hammer. » Insert a screw into each wall anchor leaving 1/4" exposed. » Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel assembly out of the case and set aside. » Line up the two keyholes on the back of the case and slip over the two screws and tighten securely. ( The lower mounting holes can be marked at this point, the case removed, holes drilled and wall anchors installed if so desired) » Remove the desired vent cap that any required wiring will route through. (If the wiring will be installed through the back-of-the-clock conduit access, route the fly leads of the clock's Cable Harness Assembly from the interior of the clock through the hole in the Clock's rear plate. Use wire nuts or crimp connectors to join these leads with the power and synch signal cable in the gang box behind the clock to eliminate possible snagging when the circuit board assembly is removed or replaced. If RS-485 signaling is used, attach the signal pair to the mini Terminal Block Plug and pass the cable from behind the clock, through the hole into the clock's interior). » Route the 6-position plug (and optional RS485 cable) to the circuit board assembly and attach. » Slide the front panel display back into the case, replace the end cap and secure with the two phillips head screws.

Mounting to a Single Gang Box Two mounting holes have been located in the center of the case 2 1/4" apart for mounting to a single gang wall box. A 7/8" hole has been placed between the mounting holes that will accept conduit if desired. See page 14, figure 3.

Page 19 of the Lathem DDC4 user manual — DDC2
Page 19 · click to enlarge
Page 19

Page 13 Digital Display Wall Clock Guide

DDC2 Note: If mounting near a ceiling, make sure the top of the single gang box is at least 2 1/4" away from the ceiling. Note: Make sure you have at least 10 1/2" of side clearance on one side in order to remove the lens and circuit board assembly. » Remove the four phillips head screws from the left or the right end cap and remove. Slide the lens and circuit board assembly out of the case and set aside. » Remove the desired vent cap that any required wiring will route through. (If the wiring will be installed through the back-of-the-clock conduit access, route the fly leads of the clock's Cable Harness Assembly from the interior of the clock through the hole in the Clock's rear plate. Use wire nuts or crimp connectors to join these leads with the power and synch signal cable in the gang box behind the clock to eliminate possible snagging when the circuit board assembly is removed or replaced. If RS-485 signaling is used, attach the signal pair to the mini Terminal Block Plug and pass the cable from behind the clock, through the hole into the clock's interior). » Line the two holes in the case up to the single gang box and insert proper screws for the single gang box and tighten securely. » Route the 6-position plug (and optional RS485 cable) to the circuit board assembly and attach. » Slide the lens and circuit board assembly back into the case, replace the end cap and secure with the four phillips head screws.

DDC4 Note: If mounting near a ceiling, make sure the top of the single gang box is at least 2 1/4" away from the ceiling. Note: Make sure you have at least 16" of side clearance on one side in order to remove the front panel. » Remove the two phillips head screws from the left or the right end cap and remove. Slide the front panel assembly out of the case and set aside. » Remove the desired vent cap that any required wiring will route through. (If the wiring will be installed through the back-of-the-clock conduit access, route the fly leads of the clock's Cable Harness Assembly from the interior of the clock through the hole in the Clock's rear plate. Use wire nuts or crimp connectors to join these leads with the power and synch signal cable in the gang box behind the clock to eliminate possible snagging when the circuit board assembly is removed or replaced. If RS-485 signaling is used, attach the signal pair to the mini Terminal Block Plug and pass the cable from behind the clock, through the hole into the clock's interior). » Line the two holes in the case up to the single gang box and insert proper screws for the single gang box and tighten securely. » Route the 6-position plug (and optional RS485 cable) to the circuit board assembly and attach.

Page 20 of the Lathem DDC4 user manual — Double Mount - Wall
Page 20 · click to enlarge
Page 20

Digital Display Wall Clock Guide Page 14

» Slide the front panel display back into the case, replace the end cap and secure with the two phillips head screws.

Double Mount - Wall

DDC2 Requires optional mounting kit (SAM0630) DDC4 Requires optional mounting kit (SAM0625) Tools required for mounting the clock: Flat blade screwdriver Phillips head screwdriver 15/16" open end wrench The double wall mount plate attaches to a double or single gang box installed securely in the wall. Required wiring should be available through the gang box at time of installation. » Remove the two chase nipples from the mounting plate posts. » Run the required wiring from the gang box through one of the mounting posts of the mounting plate. » Secure the mounting plate securely to the gang box with the proper screws. (not supplied)

Show 7 more labels / short text on this page
Vent holes · conduit For single · For 1/2" · gang box · mount · Keyholes for · wall mount
Page 21 of the Lathem DDC4 user manual — DDC2 (Double Mount - Wall)
Page 21 · click to enlarge
Page 21

Page 15 Digital Display Wall Clock Guide

DDC2 (Double Mount - Wall) » Remove the four phillips head screws from the left and the right end caps of the two DDC2 clocks and remove. Slide the lenses and circuit board assemblies out of the cases and set aside. » Place the two DDC2 clocks back to back and secure by inserting a #10 screw through the two key holes and the two lower mounting holes using lock washers and nuts supplied with the mounting kit. » Attach the modified end caps to the end of the clocks that will be attached to the wall mount plate using the original end cap screws. » Run the required wiring through the matching hole in the modified end cap. » Line the two posts from the mounting plate up with the two holes of the modified end caps. Insert the chase nipples through the holes of the modified end caps and secure to the mounting plate with a 15/16" wrench. » Slide the circuit board assemblies in partially. Secure the required wiring and install the battery if used. » Slide the circuit board assemblies in fully along with the lenses. Install the end caps and secure each with its four screws. » Discard or store the two original end caps the modified end caps replaced.

#10 lock washers #10 hex nuts

Show 6 more labels / short text on this page
mounting plate · modified end caps · chase nipples · DDC2 cases · #10 lock washers · #10 screws
Page 22 of the Lathem DDC4 user manual — Double Mount - Ceiling
Page 22 · click to enlarge
Page 22

Digital Display Wall Clock Guide Page 16

DDC4 (Double Mount - Wall) » Remove the two phillips head screws from the left and the right end caps of the two DDC4 clocks and remove. Slide the front panel assemblies out of the cases and set aside. » Place the two DDC4 clocks back to back and secure by inserting a #10 screw through the two key holes and the two lower mounting holes using lock washers and nuts supplied with the mounting kit. » Attach the modified end cap to the end of the clocks that will be attached to the wall mount plate using the original end cap screws. » Align the holes of the end cap support plate with the holes in the modified end cap and secure with 4 #6 phillips head screws (supplied) » Line the two posts from the mounting plate up with the two holes of the modified end cap. Insert the chase nipples through the holes of the modified end cap and secure to the mounting plate with a 15/16" wrench. » Slide the front panel assemblies in partially. Secure the required wiring and install the battery if used. » Slide the front panel assemblies in fully. Install the end caps and secure each with its two screws. » Discard or store the two original end caps the modified end cap replaced.

#10 lock washers #10 hex nuts

Show 7 more labels / short text on this page
mounting plate · modified end caps · DDC4 cases · end cap support · chase nipples · #10 lock washers · #10 screws
Page 23 of the Lathem DDC4 user manual — Double Mount - Ceiling
Page 23 · click to enlarge
Page 23

Page 17 Digital Display Wall Clock Guide

Double Mount - Ceiling Requires optional mounting kit (SAM0626) Tools required for mounting the clock: Flat blade screwdriver Phillips head screwdriver 15/16" open end wrench The double ceiling mount plate attaches to a double or single gang box installed securely in the ceiling. Required wiring should be available through the gang box at time of installation. » Remove the two chase nipples from the mounting plate posts. » Run the required wiring from the gang box through one of the mounting posts of the mounting plate. » Secure the mounting plate securely to the gang box with the proper screws. (not supplied) Note: When mounting DDC2 clocks, the short side of the mounting plate must be parallel to the long side of the clocks. When mounting DDC4 clocks, the long side of the mounting plate must be parallel to the long side of the clocks. See page 18, figure 6 for DDC2 details. See page 19, figure 7 for DDC4 details

Page 24 of the Lathem DDC4 user manual — DDC2 (Double Mount - Ceiling)
Page 24 · click to enlarge
Page 24

Digital Display Wall Clock Guide Page 18

DDC2 (Double Mount - Ceiling) Note: Make sure you have at least 10 1/2" of side clearance on one side in order to remove the lens and circuit board assembly. » Remove the four phillips head screws from the left and the right end caps of the two DDC2 clocks and remove. Slide the lenses and circuit board assemblies out of the cases and set aside. » Place the two DDC2 clocks back to back and secure by inserting a #10 screw through the two key holes and the two lower mounting holes using lock washers and nuts supplied with the mounting kit. Note: At this point, if the DDC2 clocks will be mounted too near a wall on one side to secure the end caps, install the "wall side" end caps now. » Remove the center vent cap from the top of each DDC2 clock. » Line the two posts from the mounting plate up with the vent holes of the DDC2 clocks. Insert the chase nipples through the vent holes and secure to the mounting plate with a 15/16" wrench. » Slide the circuit board assemblies in partially. Secure the required wiring and install the battery if used. » Slide the circuit board assemblies in fully along with the lenses. Install the end caps and secure each with its four screws.

Lathem DDC4 — DDC2 (Double Mount - Ceiling) diagram (page 24)
Fig. 2 · DDC2 (Double Mount - Ceiling)
Page 25 of the Lathem DDC4 user manual — DDC4 (Double Mount - Ceiling)
Page 25 · click to enlarge
Page 25

Page 19 Digital Display Wall Clock Guide

DDC4 (Double Mount - Ceiling) Note: Make sure you have at least 16" of side clearance on one side in order to remove the front panel assembly. » Remove the two phillips head screws from the left and the right end caps of the two DDC4 clocks and remove. Slide the front panel assemblies out of the cases and set aside. » Place the two DDC4 clocks back to back and secure by inserting a #10 screw through the two key holes and the two lower mounting holes using lock washers and nuts supplied with the mounting kit. Note: At this point, if the DDC4 clocks will be mounted too near a wall on one side to secure the end caps, install the "wall side" end caps now. » Remove the center vent cap from the top of each DDC4 clock. » Line the two posts from the mounting plate up with the vent holes of the DDC4 clocks. Insert the chase nipples through the vent holes and secure to the mounting plate with a 15/16" wrench. » Slide the front panel assemblies in partially. Secure the required wiring and install the battery if used. » Slide the front panel assemblies in fully. Install the end caps and secure each with its two screws.

Show 7 more labels / short text on this page
mounting plate · #10 hex nuts · DDC4 cases · chase nipple · chase nipple · #10 screws · #10 lock washers
Page 26 of the Lathem DDC4 user manual — Setting the Time
Page 26 · click to enlarge
Page 26

Digital Display Wall Clock Guide Page 20

Setting the Time

Time is set on the DDC Series Wall Clocks by depressing buttons located on the left side of the front panel. There are two setting buttons, "H" for hour and "M' for minute. » To advance the hour or minute to the correct time one digit at a time press and release the proper button. Do this as many times as required until the correct time is displayed. When setting the hour, if the display is set to 12 Hour, a "dot" in the upper left corner of the display represents the PM hours. » To rapidly advance the hour or minute press and hold the proper button. Release the button when the correct time is displayed. When setting the hour, if the display is set to 12 Hour, a "dot" in the upper left corner of the display represents the PM hours. Note: Setting the minutes past 59 will not cause the hour to advance. Note: Avoid using sharp or pointed objects to set the time as damage to the buttons may occur. A standard pencil eraser is suggested.

Time Formats The DDC2 / DDC4 Series Wall Clocks can be set to display in 12 Hour or 24 Hour format. When in 12- Hour format, a round LED in the upper left corner of the display indicates PM hours. When in 24 Hour format, the hours are displays in Military style. To set the display format, use Table 3 on page 4 to set switch 8 of S1. Note: When switches 1-5 are set for any secondary type other than Stand-Alone, the display is forced to 12 Hour and the PM indicator does not illuminate.

Lathem DDC4 — Setting the Time diagram (page 26)
Fig. 3 · Setting the Time

24 Hour Format AM PM

Lathem DDC4 — Setting the Time diagram (page 26)
Fig. 4 · Setting the Time

12 Hour Format

Page 27 of the Lathem DDC4 user manual — GRND AC IN AC RTN
Page 27 · click to enlarge
Page 27

Page 21 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

Appendix A - DDC2-RS / 4-RS Secondary Clock Wiring Diagrams

Stand-Alone (115VAC)

Lathem DDC4 — Stand-Alone (115VAC) diagram (page 27)
Fig. 5 · Stand-Alone (115VAC)

GRND AC IN AC RTN

Hour and Minutes must be set manually. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5 6 7 8

Page 28 of the Lathem DDC4 user manual — 3-Wire Synchronous (115VAC)
Page 28 · click to enlarge
Page 28

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 22

3-Wire Synchronous (115VAC)

BLU / WHT

Run

Correction AC Return 115VAC From Master Clock

Clock will correct minutes hourly at HH:59 and hour and minutes twice daily at 5:59.

Wiring applies to secondary wall clocks such as:

Lathem type SS Cincinnati D10 IBM 77 Series Simplex 77 Series, 93-9, 91-9, 941-9, 943-9 Stromberg 3000

1 2 3 4 5

Page 29 of the Lathem DDC4 user manual — Correction
Page 29 · click to enlarge
Page 29

Page 23 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

3-Wire Synchronous (24VAC)

BLU / WHT

GRND AC IN AC RTN

Return

24VAC From Master Clock

Correction

Clock will correct minutes hourly at HH:59 and hour and minutes twice daily at 5:59.

Wiring applies to secondary wall clocks such as:

Lathem type SS Cincinnati D10 IBM 77 Series Simplex 77 Series, 93-9, 91-9, 941-9, 943-9 Stromberg 3000

1 2 3 4

5 6 7 8

Page 30 of the Lathem DDC4 user manual — 3-Wire minute Impulse (59 th Minute)
Page 30 · click to enlarge
Page 30

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 24

3-Wire minute Impulse (59 th Minute)

YEL / WHT

VIO / WHT

GRND AC IN AC RTN

24VDC

A

B C

Clock must be set within 20 minutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

Wiring applies to secondary wall clocks such as:

1 2 3 4 5

Lathem ISC 3-Wire Standard Impulse Cincinnati D2, D4 Stromberg Impulse Edwards Impulse Faraday Impulse Simplex 75 Series, 91-4, 93-4, 941-4, 943-4 IBM 75 Series

From Master Clock

Page 31 of the Lathem DDC4 user manual — B C
Page 31 · click to enlarge
Page 31

Page 25 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

3-Wire Minute Impulse (59 th Minute With 12 Hour Correction)

YEL / WHT

VIO / WHT

GRND AC IN AC RTN

A

24VDC From Master Clock

B C

Clock will correct minutes hourly at HH:58 and hour and minutes twice daily at 5:58.

Wiring applies to secondary wall clocks such as:

1 2 3 4 5 6

Lathem ISC 3-Wire 12Hour Simplex 91, 941

Page 32 of the Lathem DDC4 user manual — AC Return
Page 32 · click to enlarge
Page 32

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 26

Standard Electric Synchronous

BLU / WHT

Run

115VAC From Master Clock

AC Return

Correction

Clock will correct minutes hourly at HH:59 and hour and minutes twice daily at 5:12.

For 24VAC applications, use wiring shown on page 18 6 7 8

1 2 3 4 5

Page 33 of the Lathem DDC4 user manual — PC
Page 33 · click to enlarge
Page 33

Page 27 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

Standard Electric AR-2A 2-Wire Dual Voltage

YEL / WHT

GRND AC IN AC RTN

To Other Clocks AB

24VDC / 48VDC From Master Clock

PC

Clock must be set to actual time. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5 6

Page 34 of the Lathem DDC4 user manual — PC
Page 34 · click to enlarge
Page 34

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 28

Standard Electric AR-2 2-Wire Dual Voltage

YEL / WHT

GRND AC IN AC RTN

To Other Clocks AB

24VDC / 48VDC From Master Clock

PC

Clock must be set to actual time. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5 6

Page 35 of the Lathem DDC4 user manual — AC Return
Page 35 · click to enlarge
Page 35

Page 29 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

Synchronous Wired

BLU / WHT

Run

115VAC From Master Clock

AC Return

Correction

Clock will correct minutes hourly at HH:58 and hour and minutes twice daily beginning at 5:05.

For 24VAC applications, use wiring shown on page 18

1 2 3 4 5

Wiring applies to secondary wall clocks such as:

Cincinnati D8 Faraday Honeywell ST402A

Page 36 of the Lathem DDC4 user manual — AC Return
Page 36 · click to enlarge
Page 36

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 30

Simplex 59 th Minute Dual Motor

BLU / WHT

Run

115VAC From Master Clock

AC Return

Correction

Clock must be set to proper hour. Clock will correct minutes hourly at HH:58. . Use of a 9Volt alkaline battery is recommended to avoid resets

For 24VAC applications, use wiring shown on page 18 7 8

1 2 3 4 5 6

Page 37 of the Lathem DDC4 user manual — AC Return
Page 37 · click to enlarge
Page 37

Page 31 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

Simplex 45 th Minute Dual Motor

BLU / WHT

Run

115VAC From Master Clock

AC Return

Correction

Clock must be set to proper hour. Clock will correct minutes hourly at HH:45. . Use of a 9Volt alkaline battery is recommended to avoid resets

For 24VAC applications, use wiring shown on page 18

1 2 3 4 5

Page 38 of the Lathem DDC4 user manual — AC Return
Page 38 · click to enlarge
Page 38

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 32

Edwards Dual Motor

BLU / WHT

Run

115VAC From Master Clock

AC Return

Correction

Clock must be set to actual time. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

For 24VAC applications, use wiring shown on page 18

1 2 3 4 5

Page 39 of the Lathem DDC4 user manual — 48 VDC Correction
Page 39 · click to enlarge
Page 39

Page 33 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

Standard Electric AR-3 3-Wire Minute Impulse

YEL / WHT

VIO / WHT

GRND AC IN AC RTN

24 VDC Pulse

24VDC / 48VDC From Master Clock

48 VDC Correction

Common

Clock must be set to actual time. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5 6

Page 40 of the Lathem DDC4 user manual — AC Return
Page 40 · click to enlarge
Page 40

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 34

National Synchronous Wired

BLU / WHT

Run

115VAC From Master Clock

AC Return

Correction

Clock will correct minutes hourly at HH:00 and hour and minutes twice daily at 6:00.

For 24VAC applications, use wiring shown on page 18

1 2 3 4 5 6

Page 41 of the Lathem DDC4 user manual — Stromberg Synchronous Wired (56 th Minute)
Page 41 · click to enlarge
Page 41

Page 35 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

Stromberg Synchronous Wired (56 th Minute)

BLU / WHT

Run

AC Return 115VAC From Master Clock

Correction

Clock will correct minutes hourly at HH:56 and hour and minutes twice daily at 11:56.

For 24VAC applications, use wiring shown on page 18 6 7 8

1 2 3 4 5

Page 42 of the Lathem DDC4 user manual — COMMON
Page 42 · click to enlarge
Page 42

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 36

Cincinnati D1

YEL / WHT

GRND AC IN AC RTN

A

24VDC / 60VDC From Master Clock

COMMON

Clock must be set within 20 minutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5

Page 43 of the Lathem DDC4 user manual — To Other Clocks PC
Page 43 · click to enlarge
Page 43

Page 37 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

Cincinnati D6, Edwards 2406

VIO / WHT

YEL / WHT

GRND AC IN AC RTN

AB

24-36VDC From Master Clock

To Other Clocks PC

Clock must be set within 20 minutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

Set switches 1-5 of SW1 as

shown.

I di d d id f

1 2 3 4 5 6

Page 44 of the Lathem DDC4 user manual — B
Page 44 · click to enlarge
Page 44

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 38

2-Wire Pulse Alternating (24VDC)

VIO / WHT

YEL / WHT

GRND AC IN AC RTN

A

24VDC From Master Clock

B

Clock must be set within 20 minutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5

Page 45 of the Lathem DDC4 user manual — Electronic Coded
Page 45 · click to enlarge
Page 45

Page 39 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

Electronic Coded

BLU / WHT

GRND AC IN AC RTN

RED GRAY

3510 Hz

Reciever

WHT

Requires 3510Hz receiver (not supplied)

Clock will correct minutes hourly at HH:57 and hour and minutes twice daily at 5:57.

1 2 3 4 5 6

Page 46 of the Lathem DDC4 user manual — Straight Frequency
Page 46 · click to enlarge
Page 46

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 40

Straight Frequency

BLU / WHT

GRND AC IN AC RTN

RED GRAY

3510 Hz

Reciever

WHT

Requires 3510Hz receiver (not supplied)

Clock will correct minutes hourly at HH:57 and hour and minutes twice daily at 5:57.

1 2 3 4 5 6

Page 47 of the Lathem DDC4 user manual — B C
Page 47 · click to enlarge
Page 47

Page 41 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

3-Wire Minute Impulse (58 th Minute)

YEL / WHT

VIO / WHT

GRND AC IN AC RTN

A

24VDC From Master Clock

B C

Clock must be set within 20 minutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5

Page 48 of the Lathem DDC4 user manual — B C
Page 48 · click to enlarge
Page 48

DDC2 / 4-RS Wiring Digital Display Wall Clock Guide Page 42

3-Wire Minute Impulse (44 th Minute)

YEL / WHT

VIO / WHT

GRND AC IN AC RTN

A

24VDC From Master Clock

B C

Clock must be set within 20 minutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5

Page 49 of the Lathem DDC4 user manual — PC
Page 49 · click to enlarge
Page 49

Page 43 Digital Display Wall Clock Guide DDC2 / 4-RS Wiring

2-Wire Reverse Polarity Minute Impulse (59 th Minute)

VIO / WHT

YEL / WHT

GRND AC IN AC RTN

AB

24VDC From Master Clock

PC

Clock must be set within 20 minutes of actual time for master to synchronize. Use of a 9Volt alkaline battery is recommended to avoid resets after power failures.

1 2 3 4 5

Page 50 of the Lathem DDC4 user manual — JP4
Page 50 · click to enlarge
Page 50

DDC2 / 4-RS -24 Wiring Digital Display Wall Clock Guide Page 44

Appendix B - DDC2-RS-24 / DDC4-RS-24 Wiring

The DDC2-RS-24 and the DDC4-RS-24 allow for 24VAC supplied from the Master Clock or Power Supply to power it for normal operation. These models can be used in installations where local 115VAC power may not be available. When shipped, the DDC2-RS-24 and DDC4-RS-24 have an optional power transformer that allows for 24VAC operation. The 24VAC power from the Master Clock or Power Supply should be connected to the two black wires leading from J1. (See figure 7 below for location of J1) Correction wiring should be applied according to the secondary type selection as shown in Appendix A. CAUTION: Applying any voltage higher than 24VAC to the input (two black leads from J1) WILL cause damage to the DDC2-RS-24 and DDC4-RS-24 clocks.

J2

9VDC Alkaline Battery Cradle

S1 J1

Hours Minutes Up Down

1 2 3 4 5 6 7 8

JP2

Lathem Time Corp. DDC2\4 (E-PROM)

JP4

JP3

JP1

J4

J3

Show 5 more labels / short text on this page
Fly Lead Connector · Jumper · DIP Switch · - + · Ground Beeper D- D+
Page 51 of the Lathem DDC4 user manual — AC Return To Other Clocks
Page 51 · click to enlarge
Page 51

Page 45 Digital Display Wall Clock Guide DDC2 / 4-RS -24 Wiring

DDC2-RS-24 / DDC4-RS-24 Wiring

BLU / WHT

Run

24VAC From Master Clock

AC Return To Other Clocks

Correction

1 2 3 4 5 6 7 8

Page 52 of the Lathem DDC4 user manual — Appendix C - RS485 Wiring Diagrams
Page 52 · click to enlarge
Page 52

DDC2 / 4-RS -485 Wiring Digital Display Wall Clock Guide Page 46

Appendix C - RS485 Wiring Diagrams

RS485 Data Format The data string that sends the time to the DDC2 / DDC4 Series Wall Clocks is formatted in such a manner that a utility can be written to achieve time updates from a personal computer. The following table shows the layout and explains each character. Data Format

0#112233445566777Z,CR The data string is compiled of a total of 16 characters. These characters represent the following. 0 Address byte # Command for Time update 11 Hex for Seconds (01-59) 22 Hex for Minutes (00-59) 33 Hex for Hour (00-23) 44 Hex for Day of Week (Sunday = 0) 55 Hex for Month (01-12) 66 Hex for Date (01-31) 777 Hex for Year offset from 1984 (000-127) Z The Checksum (1's compliment of the mod-64 sum of all characters in the string except the CR and the Checksum) CR Carriage Return Transfer of the above string must be done at 9600 Baud, 8 Data Bits, 1 Stop Bit and No Parity. Requires the SWIFT-485 plus to convert the RS232 signal from the PC to RS485 to send data to the DDC Series Wall Clocks. Note: Lathem does not offer a utility to perform this function. This information is supplied so that a 3rd party may create such a utility.

Page 53 of the Lathem DDC4 user manual — OMCII to DDC2-RS / 4-RS
Page 53 · click to enlarge
Page 53

Page 47 Digital Display Wall Clock Guide DDC2 / 4-RS -485 Wiring

OMCII to DDC2-RS / 4-RS

:

GND of JP4

D+ of JP4

Dof JP4

OMC II

GND Trans + Trans -

OMCII DB9 Female Plug

DDC2-RS / 4-RS - JP4 Connector

Pin Signal Signal JP4 Connection 1 Transmit Data (-) Transmit Data (-) D- 2 Transmit Data (+) Transmit Data (+) D+ 8 Signal Ground Signal Ground GND

Cable should be RS232 twisted pair / CAT3 or CAT5 type. Maximum distance to last DDC Clock is 4000 feet. Last DDC Clock must have jumper installed on position J2. See page 8 for details.

1 2 3 4 5 6 7

Page 54 of the Lathem DDC4 user manual — LTR0 to DDC2-RS / 4-RS
Page 54 · click to enlarge
Page 54

DDC2 / 4-RS -485 Wiring Digital Display Wall Clock Guide Page 48

LTR0 to DDC2-RS / 4-RS

GND of JP4

D+ of JP4

Dof JP4

LTR 0

BLK ORN GRY

DDC2-RS / 4-RS - JP4 Connector

Wire Signal Signal JP4 Connection Gray Transmit Data (-) Transmit Data (-) D- Orange Transmit Data (+) Transmit Data (+) D+ Black Signal Ground Signal Ground GND

Cable should be RS232 twisted pair / CAT3 or CAT5 type. Maximum distance to last DDC Clock is 4000 feet. Last DDC Clock must have jumper installed on position J2. See page 8 for details.

1 2 3 4 5 6 7

LTR0 Fly Leads

Page 55 of the Lathem DDC4 user manual — LTR4 / 8-512 to DDC2-RS / 4-RS
Page 55 · click to enlarge
Page 55

Page 49 Digital Display Wall Clock Guide DDC2 / 4-RS -485 Wiring

LTR4 / 8-512 to DDC2-RS / 4-RS

D+ of JP4

Dof JP4

11 30 :

LTR4 / 8-512

D+ D-

LTR4 / 8-512 Terminal Connections

DDC2-RS / 4-RS - JP4 Connector

Terminal # Signal Signal JP4 Connection 9 (D-) Transmit Data (-) Transmit Data (-) D- 8 (D+) Transmit Data (+) Transmit Data (+) D+

Cable should be RS232 twisted pair / CAT3 or CAT5 type. Maximum distance to last DDC Clock is 4000 feet. Last DDC Clock must have jumper installed on position J2. See page 8 for details.

1 2 3 4 5 6

Page 56 of the Lathem DDC4 user manual — D+
Page 56 · click to enlarge
Page 56

DDC-TC Timer Control Panel Digital Display Wall Clock Guide Page 50

Appendix D - DDC-TC Timer Control Panel

Wiring The DDC-TC can be connected to the DDC Series Wall Clock with a 6 conductor CAT3 or CAT5 network cable. The DDC-TC can be mounted up to 200 feet from the DDC Series Wall Clock. The DDC-TC comes with 6 wire nuts to connect the network cable to the 6 control wires mounted on the back of the DDC-TC. The 6 control wires include Up, Down, Hours, Minutes, Beeper and Ground. To wire the DDC-TC to the DDC Series Wall Clock locate JP2 and JP4 on the back of the DDC display panel (see figure 2, page 10), pass the wire through a knockout at both the DDC-TC double-gang box (not included), the DDC Wall Clock and follow the diagram below.

Rear View - Used for Reference

JP2

Green Green / White

D-

CAT3 or CAT5 Cable - 200 feet maximum

D+

Wire colors may vary. Keep in pairs as shown

DDC Series Wall Clock

Show 18 more labels / short text on this page
Hours Up · Down · Minutes · Beeper · Ground · Minutes Hours · Minutes Hours · Brown · Up · Up · Brown / White · Down · Down · JP4 Ground Beeper · Blue · Ground Beeper · Blue / White · DDC-TC Panel
Page 57 of the Lathem DDC4 user manual — Installation
Page 57 · click to enlarge
Page 57

Page 51 Digital Display Wall Clock Guide DDC-TC Timer Control Panel

Installation The DDC-TC mounts directly to a standard, double-gang wall box. (not included) Once the wiring has been attached, place the wires inside the double-gang wall box and mount the DDC-TC to the box with the four screws supplied with the DDC-TC by inserting them through the mounting holes and securing.

Lathem DDC4 — Installation diagram (page 57)
Fig. 6 · Installation

Mounting Holes · Mounting Holes

Page 58 of the Lathem DDC4 user manual — Operation
Page 58 · click to enlarge
Page 58

DDC-TC Timer Control Panel Digital Display Wall Clock Guide Page 52

Operation

As a Count Up Timer To start the count: press Count Up To pause the count: press Stop / Continue To continue the count: press Stop / Continue To return to clock mode: press Quit

As a Count Down Timer To set hours: press Set Hours (defualt is 00: ) To set minutes: press Set Minutes (defualt is :00) To start the count: press Count Down To pause the count: press Stop / Continue To continue the count: press Stop / Continue To return to clock mode: press Quit Note: To pause and continue, press the corresponding Stop / Continue button that started the operation. In the Count Down mode, when 00:00 is reached, an audible tone will sound and the display will return to clock mode. When in Count Up or Count Down mode, when the time being counted is greater than 60 minutes the display will read HH:MM. When the time being counted reaches less than 60 minutes, the display will read MM:SS.

Page 59 of the Lathem DDC4 user manual — Appendix E - LTR-GPS Satellite Receiver / Clock Synchronizer
Page 59 · click to enlarge
Page 59

Page 53 Digital Display Wall Clock Guide Specifications

Appendix E - LTR-GPS Satellite Receiver / Clock Synchronizer

Lathem’s LTR-GPS is a Global Positioning Satellite receiver using 12-channels to access the accurate date and time signal transmitted each second by 24 satellites in geosynchronous orbit around the globe. The package includes an amplified GPS Antenna, which must be mounted out-doors or beneath a roof sky- light, facing skyward. An integrated cable links the Antenna to the LTR-GPS Receiver Module, which should be mounted in-doors. The Receiver Module verifies and reformats the received satellite data, and offers multiple synchronization protocol outputs: The RS-485 Output can directly synchronize up to 31 Lathem time products, up to 4000ft away, over a single twisted-pair from a user-provided Cat-3 or Cat-5 cable. The length of cable and number of synchronized devices can be further increased using Lathem’s “SWIFT485+” RS-485 Converter / Repeater. The supported products include: LTR-0 Master Clock 1-Clock Ctl DWA-S Sonochron 1-Bell Ckt LTR4-512 Master Clock 1-Clk + 2-Ckt LTR8-512 Master Clock 1-Clk + 6-Ckt LTR8-512M Master Clock w/ Modem DDC2-RS 2” Digital Wall Clock 115v DDC2-RS-24 2” Digital Wall Clock 24v DDC4-RS 4” Digital Wall Clock 115v DDC4-RS-24 4” Digital Wall Clock 24v An included RS-232 interface provides a periodic “Time Stamp” transmission, “MM-DD-YYYY HH:MM:SS cr”, for use by computing systems having custom software to incorporate accurate date and time records in their applications: 9600,N,8,1. Use of this option requires Lathem cable, Part No. SAE0370, to be ordered separately. Simple DIP-Switch set-up enables the installer to specify local Time Zone, Daylight Savings Time corrections, and output formats. An LED indicator shows Signal Reception / Protocol Mode. The LTR-GPS may receive its power from an LTRx-512-series Master Clock, using 2nd cable pair, if the distance is less than 200ft; else, power is provided locally by a 9vAC Power Adapter.

Page 60 of the Lathem DDC4 user manual — Appendix E - LTR-GPS Satellite Receiver / Clock Synchronizer
Page 60 · click to enlarge
Page 60

Warranty Digital Display Wall Clock Guide Page 54

The LTR-GPS package includes:

LTR-GPS Satellite Synchronizer 115vAC, 2.7w, 50/60Hz Power Adapter Active GPS Antenna with 25ft. Cable Antenna Mounting Bracket and Hardware Installation and Set-Up Guide Separately, from Lathem, for Installer convenience: GPS-INSTALL-TOOLS: Battery / Beeper assemblies aid in Antenna positioning LTR-GPS Specifications:

Size / Weight 3.25”x 2”x6.6” / 1 lb. Power: 6-12vAC/DC, 300mA (max) Certificates: FCC Part-15, ICES003

Page 61 of the Lathem DDC4 user manual — Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clock
Page 61 · click to enlarge
Page 61

Page 55 Digital Display Wall Clock Guide Specifications

Lathem DDC4 — Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clock diagram (page 61)
Fig. 7 · Connecting to a Lathem DDC2-RS or DDC4-RS Digital Cl…

Connecting to a Lathem DDC2-RS or DDC4-RS Digital Clock

Page 62 of the Lathem DDC4 user manual — Appendix F - Specifications
Page 62 · click to enlarge
Page 62

Warranty Digital Display Wall Clock Guide Page 56

Appendix F - Specifications

Dimensions DDC2 4 7/8" H X 10 1/4" W X 3 1/8" D 12.4 cm H X 26.2 cm W X 7.9 cm D DDC4 6 3/4" H X 15 1/2" W X 3 1/8" D 17.1 cm H X 39 cm W X 7.9 cm D Weight DDC2 3.2 lbs (1.451 kg) DDC4 9 lbs. (4.086 kg) Display DDC2 1 3/4-Inch Red 7 Segment LED DDC4 3 3/4-Inch Red 7 Segment LED Housing DDC2 Extruded aluminum main case with black textured paint, red lexan panel; steel end caps with black textured paint. DDC4 Extruded aluminum main case with black textured paint, steel front panel with black textured paint; molded plastic end caps with black texture. Line Power DDC2 / DDC4 115VAC, 80mA typical 220VAC, 80mA typical (optional) DDC2-RS-24 / DDC4-RS-24 24VAC, 400mA typical Standby Power DDC2 / DDC4 9VDC, 1.2mA Alkaline Battery (not included) Environment DDC2 / DDC4 32o to 150 o F (0 o to 65 o C) 95% Relative Humidity (non-condensing) Correction Signal 115VAC, 6.5mA 24VDC, 16mA 48VDC, 40mA 60VDC, 56mA 24VAC, 6.5mA Mounting DDC2 / DDC4 Wall (surface) Single Gang Box (surface) Double Face (wall or ceiling) (optional)

Page 63 of the Lathem DDC4 user manual — Appendix G - Warranty
Page 63 · click to enlarge
Page 63

Page 57 Digital Display Wall Clock Guide Specifications

Appendix G - Warranty

Limited One-Year Limited Warranty Lathem warrants the hardware products described in this guide against defects in material and workmanship for a period of one year from date of original purchase from Lathem or from an authorized Lathem reseller. The conditions of this warranty and the extent of the responsibility of Lathem Time Corporation (“Lathem”) under this warranty are listed below.

1. This warranty will become void when service performed by anyone other than an approved Lathem warranty service dealer results in damage to the product. 2. This warranty does not apply to any product which has been subject to abuse, neglect, or accident, or which has had the serial number altered or removed, or which has been connected, installed, adjusted, or repaired other than in accordance with instructions furnished by Lathem. 3. This warranty does not cover dealer labor cost for removing and reinstalling the machine for repair, or any expendable parts that are readily replaced due to normal use. 4. The sole responsibility of Lathem under this warranty shall be limited to repair of this product, or replacement thereof, at the sole discretion of Lathem. 5. If it becomes necessary to send the product or any defective part to Lathem or any authorized service dealer, the product must be shipped in its original carton or equivalent, fully insured with shipping charges prepaid. Lathem will not assume any responsibility for any loss or damage incurred in shipping. 6. WARRANTY DISCLAIMER AND LIMITATION OF LIABILITY: Except only the limited express warranty set forth above, the products are sold with no expressed or implied warranties of any kind, and the implied warranties of merchantability and fitness for a particular purpose are hereby expressly disclaimed. No warranties are given with respect to products purchased other than from Lathem or an authorized Lathem reseller and any such products are purchased "as is, with all faults." In no event will Lathem be liable for any direct, indirect, special, incidental or consequential damages arising out of or in connection with the delivery, use or inability to use, or performance of this product. In the event any limited remedy given herein shall be deemed to have failed of its essential purpose, Lathem's maximum liability shall be to refund the purchase price upon return of the product. 7. Proof of date of purchase from Lathem or an authorized Lathem reseller is required for warranty service on this product. 8. This Warranty grants specific legal rights. Additional legal rights, which may vary by locale, may also apply. 9. Should any difficulties arise with the performance of this product during warranty, or with any Lathem authorized service centers, contact Lathem Time at the address below.

Lathem Time 200 Selig Drive, SW, Atlanta, GA 30336 404-691-0405

www.lathem.com

Copyright © 2003 Lathem Time Corporation. All rights reserved.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Lathem DDC4

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Lathem DDC4

Be the first to ask — other owners or our team will answer.

Original document

Lathem DDC4 manual PDF

63 pages·1.1 MB·Clock·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…