Multiport Device Servers
Revision A April 2005
Part Number 900-401

The information in this guide may change without notice. The manufacturer assumes no responsibility for any errors which may appear in this guide.
AppleTalk, Chooser, and Macintosh are trademarks of Apple Computer Corp. LaserJet and Bitronics are trademarks of Hewlett Packard. Centronics is a registered trademark of Centronics Data Computer Corp. PostScript is a trademark of AdobeSystems, Inc. DEC and LAT are trademarks of Digital Equipment Corporation. Ethernet is a trademark of XEROX Corporation. NetWare is a trademark of Novell Corporation. UNIX is a registered trademark of The Open Group. Windows for Workgroups, Windows 95, Windows 98, Windows 2000, and Windows NT are trademarks of Microsoft Corporation.
Copyright 2004, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix. Printed in the United States of America.
Lantronix Corporate Headquarters 15353 Barranca Parkway Irvine, CA 92618, USA Phone: 949-453-3990 Fax: 949-453-3995
Sales Offices For a current list of our domestic and international sales offices, go to the Lantronix web site at http://www.lantronix.com/about/contact/index.html

This product has been designed to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against such interference when operating in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with this guide, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause interference in which case the user, at his or her own expense, will be required to take whatever measures may be required to correct the interference.
Changes or modifications to this device not explicitly approved by Lantronix will void the user's authority to operate this device.
Cet appareil doit se soumettre avec la section 15 des statuts et règlements de FCC. Le fonctionnement est subjecté aux conditions suivantes:
(1)Cet appareil ne doit pas causer une interférence malfaisante.
(2) Cet appareil doît accepter n'importé quelle interférence reìue qui peut causer une opération indésirable.
The information in this guide may change without notice. The manufacturer assumes no responsibility for any errors that may appear in this guide.
Date Rev. Comments 4/05 A Initial Document


LPR on Windows NT 3.5.1 (and later) 25 LPR on Windows 95/98 32 LPR on UNIX Hosts 32 LPR on AIX Hosts 33 LPR on HP Hosts 34 LPR on SCO UNIX Hosts 34 RTEL Functionality 35 Unix Host Troubleshooting 36
Obtain an NDS License 37 Configure your ETS 37 NetWare Administrator Quick Setup Print Queues 38 PCONSOLE Print Queues 38 NetWare Host Troubleshooting 39
ETS Configuration 46 Host Configuration 46
A: Contact Information 47
B: Troubleshooting 48 Power-up Troubleshooting 48 DHCP Troubleshooting 49 BOOTP Troubleshooting 49 RARP Troubleshooting 50 Entering Commands at the Boot Prompt 50
C: Pinouts 53 Ethernet Connector 53 RJ45 Serial Connectors 53
RJ45 to DB25 53 RJ45 to DB9 55
D: Updating Software 56
Contents


The Lantronix ETS (ETS8PS, ETS16PS, ETS16PR, and ETS32PR) is a multi-port device server providing shared network access to terminals, devices, console ports, and printers for a variety of network protocols and operating systems. The ETS supports the TCP/IP, IPX (NetWare), Local Area Transport (LAT), AppleTalk (EtherTalk), and Microsoft LAN Manager protocols.
The ETS stores its executable software in Flash (rewritable) ROM, meaning that it does not have to download software from a host each time it boots. Software must only be downloaded when a new software version becomes available. See D:Updating Software for more information.
All ETS models support the RS-232/423 serial protocol.
The RS-232 line interface standard is a single-ended peer-to-peer interface. Today's personal computers typically have at least one RS-232 serial port. It is the most common serial protocol used today.
RS-232 is used for connecting devices across short distances at speeds up to 230.4 kb/s. Faster speeds require shorter cabling to ensure error-free communication. The maximum cable length at a given speed is determined by many factors, including the immediate electrical environment and the quality of cable used, but is usually less than 15 meters at high speeds.
RS-423 All of the ETS models support the RS-423 line interface standard. RS-423 devices are interoperable with RS-232 devices. That is, RS-232 ports can receive data reliably from RS-423 ports and vice-versa.
The main difference between RS-423 and RS-232 is that RS-423 employs lower voltage signaling and differential receivers. RS-423 still uses single-ended transmitters for compatibility with RS-232 receivers.
RS-423 is generally rated at higher speeds over longer cabling runs than RS-232. Maximum data rates of 230.4 kb/s are possible on ETS-PR models, and 115.2 kb/s is the maximum on ETS-P models.

2:Installation Explains how to physically install the ETS.
3:Getting Started Explains the minimum configuration needed.
4:Using the ETS Explains some of the ways that you can use your ETS.
5:Printing on the ETS 6:NetWare Configuration 7:LAT Configuration 8:AppleTalk Configuration 9:DLC Configuration for LAN Manager
Chapters 5 through 9 cover protocol-specific setup needed to install print queues and otherwise use the ETS.
A:Contact Information B:Troubleshooting C: Pinouts D:Updating Software E:Specifications F:Frequently-Used Commands G:Compliance and Warranty Information
Appendices A through F provide supplementary information.
Read chapters 2 through 4 in order, then proceed to the protocol-specific chapter that relates to your network. Refer to F:Frequently-Used Commands as needed. The Device Server Reference Manual, located on the CD-ROM and web site, provides additional information about configuring and using your ETS.
Introduction

This chapter describes the various ETS models and shows how to install them into a basic network configuration. The ETSPS models will be explained first. For ETSPR descriptions and installation instructions, skip to ETSPR Product Descriptions.
ETSPS Front Panels The front panel of all ETSP models has a Test/Reset button (called Reset on the ETS8PS and ETS16PS), seven LEDs, and a power switch. Pressing the Reset button for 5 seconds while the unit powers up will flush the NVR (factory reset).
ETS8PS/ETS16PS LEDs The seven LEDs are explained in the following table.
Table 2-1. ETS8PS/ETS16PS LED Functionality
PWR Lights to indicate the ETS has power
LNK Lights to indicate a functional 10BASE-T network link
POL Lights to indicate a swapped 10BASE-T cable
OK Blinks to indicate that the ETS is functioning properly
NET Blinks to indicate Ethernet activity
RCV Blinks periodically to indicate serial characters entering the ETS
XMT Blinks periodically to indicate serial characters exiting the ETS
ETS8PS Back Panel The back panel of the ETS8PS has a power plug, an AUI Ethernet port, an RJ45 10BASE-T Ethernet port, and eight RJ45 serial ports.
LED Function

Figure 2-1. ETS8PS and ETS16PS Back Panels

ETS16PS Back Panel The back panel of the ETS16PS has a power plug, an AUI Ethernet port, a 10BASE- T Ethernet port, and 16 RJ45 serial ports.
Figure 2-2. ETS16PS Back Panel

The following two diagrams show properly-installed ETSP servers.
Figure 2-3. Sample ETS8P/ETS16PS Network Layout (ETS8PS shown)

Installation

To install the ETS, complete the following steps in order. Refer to the numbers in the previous figure.
When choosing a location, keep in mind the environmental restrictions discussed in E:Specifications.
a) It runs through a set of power-up diagnostics for approximately 12 seconds.
The LEDs show varying patterns corresponding to the tests being run.
b) It tries to obtain TCP/IP configuration information via DHCP, BOOTP, and
RARP. This may take as long as 15 seconds if no hosts answer the requests. During this step, the OK LED blinks approximately 3 times per second and the NET LED blinks occasionally.
ETS16PR Front Panel The ETS16PR has 16 RJ45 serial ports, a Reset button, an AUI Ethernet port, an RJ45 Ethernet port for 10/100BASE-T, several LEDs, and a power switch.
Figure 2-4. ETS16PR Front Panel

Installation

ETS32PR Front Panel The ETS32PR has 32 RJ45 serial ports, a Reset button, an AUI Ethernet port, an RJ45 Ethernet port for 10/100BASE-T, several status LEDs, and a power switch.
Figure 2-5. ETS32PR Front Panel

ETSPR LEDs Each ETSPR has a total of 37 LEDs. Each serial port has one (ETS32PR) or two (ETS16PR) corresponding LEDs that indicate receive and transmit activity, and there are five status LEDs on the right side of the case.
Table 2-2. ETSPR Port LED Functionality
activity Blinks to indicate Ethernet activity
ok Blinks to indicate that the ETS is functioning properly
100 Lights to indicate a 100BASE-T rather than 10BASE-T Ethernet link
link Lights to indicate a functional Ethernet network link
power Lights to indicate the ETS has power
The following diagram shows a properly-installed ETS16PR. Installation will generally be the same for all ETSPR models, the only difference being the number of serial ports available. See ETSPR Product Descriptions on page 11 for more information.
Installation · LED Function

Figure 2-6. Sample ETSPR Network Layout (ETS16PR shown)

To install the ETS, complete the following steps in order:
Figure 2-7. Rack Mount Bracket Installation

Installation

a) It runs through a set of power-up diagnostics for approximately 12 seconds.
The LEDs show varying patterns corresponding to the tests being run.
b) It tries to obtain TCP/IP configuration information via DHCP, BOOTP, and
RARP. This may take as long as 15 seconds if no hosts answer the requests. During this step, the OK LED blinks approximately 3 times per second and the NET LED blinks occasionally.
Installation

It is important to consider the following points before logging into and configuring the ETS:
You must configure the ETS IP address before any TCP/IP functionality is
available. You cannot use the ThinWeb Manager until you have configured an IP address.
Changing any server, service, or port setting requires privileged user status.
The default privileged password is system.
The login password is required for remote console logins. The default login
username is access. The login password is not required by default. Note: If you would like to change either the privileged or login password, either use EZWebCon or refer to the Device Server Reference Manual located on the CD-ROM.
EZWebCon The EZWebCon configuration software is the recommended way to configure the ETS. EZWebCon’s graphical user interface guides first time users through the initial configuration process and allows experienced users to update any configurable parameters.
EZWebCon requires a Java Virtual Machine (JVM) on the client. Lantronix provides JVM installers for Solaris and 32-bit Windows users, as well as source code and instructions for compiling it for other systems.
The EZWebCon software is located on the distribution CD-ROM. All instructions for installing EZWebCon are provided in the README file. For assistance once EZWebCon is running, refer to the EZWebCon on-line help.
Using a Web Browser (ETSPR models) The ThinWeb Manager web browser interface allows you to log into and configure your ETS using a standard web browser with JavaScript enabled. Simply type the ETS IP address or resolvable text name into the browser’s URL/Location field (for example, http://111.222.333.444).
Figure 3-1. Sample Web Browser Login


Once you have connected to the ETS, you will see the Lantronix ThinWeb Manager interface. Use the left-hand menu to navigate to subpages where you can configure important settings as well as view statistics and other server information.
Figure 3-2. ThinWeb Manager Interface

Incoming Logins Incoming logins made via EZWebCon can be used to configure the ETS. Incoming LAT and TCP/IP logins can also be used.
Incoming Telnet is only possible if your ETS has an IP address configured. Incoming Telnet is enabled by default to allow TCP/IP connections. To change this setting, use the Define Server Incoming command described in the Command Reference chapter of the Device Server Reference Manual located on the CD-ROM.
Incoming logins do not prompt for a login password, so you may wish to disable them for security reasons. If it is undesirable to disable incoming logins, the ETS can be configured to prompt for a password with the Define Server Incoming Password Enabled command.
Console Terminal To configure the ETS via a console terminal, attach a terminal to the serial console port (port 1) and press the Return key. You will see a Local> prompt at which you can enter configuration commands.
The EZWebCon configuration software is the easiest way to configure the ETS. The following sections cover IP address configuration methods for TCP/IP hosts.
The ETS IP address must be configured before any TCP/IP functionality is available. Use one of the following methods to set the IP address: EZWebCon; a directed Ping packet; a BOOTP, DHCP, or RARP reply; or commands entered via the command line interface on a terminal console.
Using EZWebCon Use the following steps to assign an IP address using the EZWebCon Expert Shell.
a) For Ethernet Address, enter the number that appears on the bottom label of
your ETS.
Getting Started

b) For IP Address, enter the desired IP address to use for this ETS. The IP
address should be on the same subnet as the PC running EZWebCon.
c) For Subnet Mask, change the values provided only if you wish to use a mask
other than the default. The default value should be correct in most cases.
d) For Loadhost, enter the IP address of the loadhost where you intend to store
your operating code.
Using a Directed Ping Packet The ARP/ping method is available under UNIX and Windows-based systems. If the ETS has no IP address, it will set its address from the first directed IP packet it receives.
On a UNIX host, create an entry in the host’s ARP table and substitute the intended IP address and the hardware address of the ETS, then ping the ETS. This process typically requires superuser privileges. The IP address should be on the same subnet as the PC running EZWebCon.
Figure 3-3. ARP and Ping on UNIX
# arp -s 192.0.1.228 00:80:a3:xx:xx:xx % ping 192.0.1.228 In order for the ARP command to work on Windows 95, the ARP table on the PC must have at least one IP address defined other than its own. If the ARP table is empty, the command will return an error message. Type ARP -A at the DOS command prompt to verify that there is at least one entry in the ARP table.
Figure 3-4. ARP and Ping on Windows
C:\ ARP -S 192.0.1.228 00-80-A3-XX-XX-XX C:\ PING 192.0.1.228 Note: There should be replies from the IP address if the ARP command worked.
When the ETS receives the ping packet, it will notice that its IP address is not set and will send out broadcasts to see if another node is using the specified address. If no duplicate is found, the ETS will use the IP address and will respond to the ping packet.
The ETS will not save the learned IP address permanently; this procedure is intended as a temporary measure to enable EZWebCon to establish communication and allow an administrator to Telnet into the ETS. Once logged in, the administrator can enter the Define Server IPaddress command to make the address permanent.
Figure 3-5. Configuring Permanent IP Address
% telnet 192.0.1.228 Trying 192.0.1.228 Lantronix ETSx Version n.n/n (yymmdd)
Getting Started

Type Help at the ‘Local_>’ prompt for assistance. Enter Username> gopher Local> SET PRIVILEGED Password> system (not echoed) Local>> DEFINE SERVER IPADDRESS 192.0.1.228 Local>> DEFINE SERVER SUBNET MASK 255.255.255.0 Any host wishing to access the ETS will have to be told the ETS’ IP address. This is typically configured in the UNIX file /etc/hosts or via a nameserver. Refer to the host’s documentation for additional information.
Using a BOOTP, DHCP, or RARP Reply At boot time a host-based DHCP, BOOTP, or RARP server can respond to an ETS request for an available IP address. For information about configuring the DHCP, BOOTP, or RARP server, see your host documentation.
Using the Command Line Interface 1. Connect to the serial port (Port_1) using a console terminal or a terminal emulation program, and press Enter. The serial port settings are 9600 baud, 8 bits, 1 stop bit, no parity.
Figure 3-6. Becoming the Privileged User
Local> SET PRIVILEGED Password> system (not echoed) Local>> 3. Enter the new IP address.
Figure 3-7. Configuring the IP Address
Local>> define server ipaddress 192.0.1.201 Local>> DEFINE SERVER SUBNET MASK 255.255.255.0 For additional command line reference (for use with Telnet or a terminal console), see the ETS Reference Manual available for download from www.lantronix.com/support/docs/index.html.
If the ETS appears to be working and the unit is connected to the network, there are a couple of ways to confirm that the unit is visible to network hosts:
If the ETS has an IP address, ping it from a TCP/IP host.
If the ETS has an IP address, use EZWebCon to log into it. When you are satisfied that the ETS is working properly, proceed to 3:Getting Started. If the ETS does not boot properly, see B:Troubleshooting.
Getting Started

The sections in this chapter show how to use the ETS in a variety of applications.
For detailed instructions on how to set up the ETS as a console server, see Console Server Example.
For instructions on how to use the ETS in serial tunnel mode, see Serial Tunnel Example on page 23.
For information about using the ETS with the Lantronix Comm Port Redirector, see Comm Port Redirector on page 24.
Keep in mind that you must reboot the ETS after issuing a Define command. The command will take effect when the ETS reboots. The one exception is that Define Port commands take effect when a port is logged out.
When you use the ETS as a console server, you can remotely manage devices and equipment from anywhere on the network.
Figure 4-1. Console Server

To use the ETS as a console server, you must connect the ETS serial ports to the serial console/management ports of other equipment such as UNIX servers, PBX switches, routers, network switches, or other similar devices.
Once you have completed the connections, you can establish a Telnet connection to the ETS IP address and socket number of the desired port. The ETS serial ports allow two types of socket connections: Telnet IAC interpretation at socket 200x, and raw TCP connections at socket 300x, where x is the port number. For example, to open a Telnet connection to port 4 of an ETS at IP address 192.0.1.168, you would issue the command “Telnet 192.0.1.168 2004” from your system prompt. In a Windows environment, use a space instead of a colon in the command syntax.

In addition to direct Telnet connections, you can use the ETS’ built-in menu feature. The ETS menu allows you to connect to the IP address of the ETS and be greeted with a menu with which to connect to each attached serial device. Menu choices are an easy way to let users access often-used hosts and services without needing to know any ETS command syntax, the IP addresses of the non-local devices, or the socket numbers involved.
Figure 4-2. Sample Menu

Define the Menus To give your menu a name, use a Define Menu Title command.
Figure 4-3. Menu Title
Local>> DEFINE MENU TITLE “Lantronix Console Server:”
Create menus entries with the Define Menu command. (To temporarily test menu entries without making them permanent, you may choose to use the Set Menu command.) Users type the number of the command they wish to execute and press Enter.
The basic syntax of the Define Menu command includes:
a menu item number
a menu item name
a command that is executed when the user chooses that menu item.
Figure 4-4. Generic Menu Command
Local>> DEFINE MENU n “Name” “command”
There are three types of menu entries.
Those that connect users to devices on the network (see Figure 4-5)
Those that connect users to devices attached to the ETS (see Figure 4-6)
Those that function locally on the ETS (see Figure 4-7) To allow users to connect to a device on the network from a terminal connected to the ETS, use a Telnet command.
Figure 4-5. Menu Entries for network Connections
Local>> DEFINE MENU 1 “Cisco Router” “telnet 192.0.1.250;kill” Local>> DEFINE MENU 2 “Sun Server” “telnet 192.0.1.251;kill”
To allow users to connect from the network to a device connected to the ETS (or from one ETS port to another) add a Connect Local command.
Using the ETS

Figure 4-6. Menu Entries for manipulating the ETS
Local>> DEFINE MENU 3 “HPUX Server” “connect local port_3” Local>> DEFINE MENU 4 “Linux Server” “connect local port_4” Local>> DEFINE MENU 5 “PBX Switch” “connect local port_5”
To allow users to access a local service on the ETS, add a general ETS command.
Figure 4-7. Menu Entries for manipulating the ETS
Local>> DEFINE MENU 6 “ETS Prompt” “exit” Local>> DEFINE MENU 7 “Logout” “logout”
NOTE: The Exit command only works in menu mode. It allows users to return to the Local> prompt on the ETS on which the menu was configured. It is helpful to include this command in your menus until you have full tested them – otherwise there is no way for users on menu mode ports to return to the Local> prompt.
To review the menu that you have just created, type List Menu at the Local> prompt. The menu created by the previous commands would look like this:
Figure 4-8. New Menu
Local_1>> show menu Title for the menu is "Lantronix Console Server" 1: Cisco Router --> "telnet 192.0.1.250;kill" 2: Sun Server --> "telnet 192.0.1.251;kill" 3: HPUX Server --> "connect local port_3" 4: Linux Server --> "connect local port_4" 5: PBX Switch --> "connect local port_5" 6: ETS Prompt --> "exit" 7: Logout --> "logout"
Enable Menu Mode You must enable menu mode for all ports on which you wish the menu system to work. Ports 2-4 will be used for the examples in this section.
Figure 4-9. Enabling Menu Mode
Local>> DEFINE PORT 2-4 MENU ENABLED Local>> LOGOUT PORT 2-4 Note: If you want incoming logins from the network to be able to use the menu, you must enable menu mode on port 0.
Users who Telnet into the ETS would see the menu rather than the Local> prompt.
Configure Switches Switches allow users to move around within open sessions and return to the ETS Local> prompt if needed. Configure a local switch to return to the local prompt. Also, configure backward and forward switches if you intend to allow serial port users to hold multiple sessions to remote servers. You must set switches for all of the ports for which menu mode is enabled (see Define the Menus on page 20).
Any key may be used for a switch, provided that the chosen keys do not interfere with the sessions. To use a control key, type a carat (^).
Using the ETS

Figure 4-10. Configuring Switches
Local>> DEFINE PORT 2-4 LOCAL SWITCH ^X Local>> DEFINE PORT 2-4 FORWARD SWITCH ^F Local>> DEFINE PORT 2-4 BACKWARD SWITCH ^B Local>> DEFINE PORT 2-4 BREAK LOCAL Note: Define Port Break Local allows the ETS to recognize the switches you just configured.
To check switch configurations, enter the Show/List Port command and specify the ports that are used for menu mode.
Figure 4-11. Show Port Screen

Using Menus When you log into a port with menu mode enabled, you will be presented with an initial login screen.
Figure 4-12. Login Screen
Lantronix ETSxx Version B3.6/3 (000410) Type HELP at the 'Local_10> ' prompt for assistance. Username> 1. Enter your user name (in this case, Bob) and press Enter.
Figure 4-13. Login Screen, part 2
Username> Bob Press to continue... 2. As instructed, press the Return key once more to see the actual menu.
Figure 4-14. Login Menu

Using the ETS

Two ETS device servers can be connected to emulate a direct serial connection across a LAN or WAN. Servers connected in this way can pass data only—they will not be able to pass status signals (DSR/DTR, CTS/RTS, etc.) or preserve timing between characters. The basic network configuration for this virtual serial line is shown in Figure 4-15.
Figure 4-15. Back-to-Back ETS Connections

TCP Configuration Assuming the ETS serial port parameters have been configured properly, the ETS device servers in Figure 4-15 are configured as follows:
Local>> DEFINE PORT 2 DEDICATED TELNET 192.168.5.10:3001T
Local>> DEFINE PORT 2 AUTOSTART ENABLED
Local>> DEFINE PORT 3 ACCESS REMOTE
Local>> DEFINE PORT 3 DEDICATED NONE
Local>> DEFINE PORT 3 AUTOSTART DISABLED
The above commands create a raw (8-bit clean) TCP connection between ETS_A port 2 and ETS_B port 3 once the units have been power-cycled. The commands for ETS_A ensure that it will automatically connect to ETS_B each time it is booted. The commands for ETS_B ensure that it is always available to accept connections from ETS_A. Once this connection is made, data is able to travel in both directions.
Using the ETS

UDP Configuration When the UDP protocol is used, there is no connection; each ETS must be told explicitly which hosts it is allowed to accept packets from. Each ETS would have to be configured to both send packets to and accept packets from the other ETS.
Local>> DEFINE PORT 2 DEDICATED TELNET 192.168.5.10:4096U
Local>> DEFINE PORT 2 AUTOSTART ENABLED
Local>> DEFINE PORT 2 ACCESS DYNAMIC
Local>> DEFINE PORT 3 DEDICATED TELNET 192.168.5.2:4096U
Local>> DEFINE PORT 3 AUTOSTART ENABLED
Local>> DEFINE PORT 3 ACCESS DYNAMIC
Setting up dedicated hosts ensures that the units will always talk to each other. Enabling Autostart for both units enables one ETS to send data to the other ETS without having to wait for a serial carriage return to start the session. ETS_B knows exactly which other ETS to accept connections from. Finally, when Autostart is enabled, the access mode must be either Local or Dynamic (Dynamic is more flexible).
Multi-port Serial Tunnel Configuration You can create serial tunnels for any available ports on the ETS. Each serial tunnel must point from one ETS port to one different serial device port (such as a serial port on an ETS, MSS, or UDS server).
Comm Port Redirector The Lantronix Comm Port Redirector application allows PCs to share modems and other serial devices connected to an ETS using Microsoft Windows or DOS communication applications. The Redirector intercepts communications to specified Comm ports and sends them over an IP network connection to the ETS serial port. This enables the PC to use the ETS serial port as if it were one of the PC Comm ports. Using their existing communications software, PC users dial out to a remote host through a modem connected to the ETS.
The Comm Port Redirector software and installation instructions are included on the distribution CD-ROM and are available for download from ftp://ftp.lantronix.com.
Using the ETS

The EZWebCon configuration software is the easiest method for ETS configuration. The following sections cover print configuration methods for TCP/IP hosts.
The ETS provides several major methods of printing via TCP/IP such as TCP/IP socket printing and Berkeley remote LPR and RTEL host software.
Two parameters must be configured for LPR printing:
In addition, there are a few important things to note about LPR printing:
Windows for Workgroups, Windows 95, and Windows 98 do not support LPR
directly; however, Lantronix has provided a peer-to-peer printing solution on the distribution CD-ROM.
Because of the way the LPR protocol is typically implemented on the host,
the processing options and banner page are sent after the job data itself. The ETS will print a banner page at the end of a job, and cannot support most of the LPR options. If it is necessary to have the banner page at the beginning of the printout, install and use the RTEL software. If banners are not needed, they can be disabled.
The ETS cannot print multiple copies of the print job when using the “-#n” lpr
option.
If two print queues on the host refer to two services on the same ETS, they
must use separate spooling directories.
No special purpose input or output filters can be used when printing via LPR.
If this functionality is necessary, use the named pipe interface program in the RTEL print queue configuration software.
Services With few exceptions, you must create a service before you can configure print queues on the ETS. A service is a resource accessible to network hosts. A Lantronix service is also known as a remote printer name or remote queue name on many operating systems.
LPR on Windows 2000, XP, and 2003 Two methods of printing to the Lantronix ETS devices are supported by Windows 2000, XP and 2003.

Printing on the ETS
Creating a Standard TCP/IP port allows communication through a RAW
Telnet port. This is supported by default.
Creating a LPR port allowing jobs to be submitted to a “Service” offered by
the ETS. Services are the basic method allowing the ETS to provide a queuing mechanism to a network host. (See the ETS Reference Manual for in-depth instructions on creating queues.) To enable LPR support, install Print Services for UNIX:
To initiate either of the print methods, follow these steps:


Printing on the ETS



Printing on the ETS



Printing on the ETS
To determine the services running on the ETS do the following:
Access the ETS Local> prompt (via telnet or a terminal console).
Type SET PRIV and enter the privileged user password (default password is SYSTEM) .
Type SHOW SERVICES LOCAL.
To configure a service, use the following commands from the privileged user prompt on the ETS:
Local>> DEFINE SERVICE (ETS_HPLaserjet) port (x) enable (substitute your own values for the entries in parentheses) Local>> INITIALIZE DELAY 0
After the reboot use the following command to display the status of the newly defined service:
Local>> SHOW SERVICE (ETS_HPLaserjet) CHAR


Printing on the ETS

LPR on Windows NT 3.5.1 (and later) This section assumes that TCP/IP, Simple TCP/IP, and Microsoft TCP/IP printing have been installed on the Windows NT host.


Printing on the ETS




Printing on the ETS



LPR on Windows 95/98 Lantronix provides a utility to enable LPR printing on Windows 95/98. To request this utility, contact Lantronix Technical Support and ask for “ltxlpr.exe”.
LPR on UNIX Hosts The Berkeley remote printing system is supported on many machines, and is simple to configure. This section describes how to configure LPR print queues on generic UNIX hosts such as SUN hosts. There are slight variations in LPR configuration for AIX, HP, and SCO hosts, as will be explained in the following sections.

Printing on the ETS
Figure 5-1. Adding /etc/hosts Entry
xxx.xxx.xxx.xxx ETS_xxxxxx 2. Add the host print queue to the /etc/printcap file. The punctuation shown in Figure 5-7 is required, and no extra spaces should be added.
Figure 5-2. Adding /etc/printcap Entry
ets_prt|Printer on LAB ETS:\ :rm=ETS_xxxxxx:\ :rp=ETS_xxxxxx_TEXT:\ :sd=/usr/spool/lpd/ets_prt:
This will create a host queue named ets_prt. The rm parameter is the name of the ETS in the host's address file, the rp parameter is the name of the service as it exists on the ETS, and the sd parameter specifies the name of a directory used to hold temporary spooling files.
Figure 5-3. Creating Spooling Directory
# mkdir /usr/spool/lpd/ets_prt # chmod 777 /usr/spool/lpd/ets_prt
Figure 5-4. Printing to Queue
% lpr –P ets_prt /etc/hosts
LPR on AIX Hosts The System Management Interface Tool (SMIT) allows you to enable LPD printing and create print queues. LPR has only been tested on AIX versions 3.2 and higher.
To create a print queue:
To add a print queue:

Printing on the ETS
The name of the print queue,
The name of the ETS unit,
The name of the ETS service,
The type of print spooler on the remote server, and
A description of the printer on the remote server. 7. A dialog box will appear: “Added print queue ets_prt”. Click Done.
Figure 5-5. Printing to Queue
% lp -dets_prt filename
LPR on HP Hosts The System Administration Manager (SAM) allows you to create print queues.
To create a print queue:
The printer name (the name of the print queue),
The remote system name (the ETS name),
The remote printer name (the ETS service),
The remote cancel model, and
The remote status model.
LPR on SCO UNIX Hosts LPR is supported in SCO V3.2 release 4 with TCP/IP Version 1.2 and greater.
To configure a print queue using LPR, issue the mkdev rlp command. This will install the Berkeley remote printing files and executable programs.
You can print to this queue using normal lp syntax once the remote printer is set up. To create a remote printer:

Printing on the ETS
Figure 5-6. Configuring Remote Printer
Remote Printing Configuration Enter information for remote printers or local printers accepting remote printing requests Please enter the printer name (q to quit): backupprinter Is printer backupprinter a remote printer or a local printer? (r/l) r Please enter the name of the remote host that backupprinter is attached to: ETS_xxxxxx The backupprinter is connected to host ETS_xxxxxx. Is this correct? (y/n) y Would you like this to be the sys.default printer? (y/n) y Make sure your hostname appears in ETS_PRT’s /etc/hosts.equivor or /etc/hosts:lpd file. Make sure backupprinter appears in /etc/printcap (in BSD format). Make sure backupprinter has a spool directory on ETS_PRT. Putting the printer in printer description file and creating spool directory... done Updating LP information... done
In the example, the printer name is your ETS service name, and the remote host name is the name of your ETS as it is listed in your hosts file.
During initial configuration, the queue name must be the same as the remote printer name. However, you may change the queue name later by manually editing the printcap file.
RTEL Functionality If the LPR method of printing is not adequate for an application (for example, if you need banners before jobs, or more flexibility), configure the Lantronix-supplied RTEL software on the host. After installing the software configuring the connections to the ETS, you can use normal UNIX print commands and queue utilities such as lpc and lpstat.
To print to the ETS using special formatting or using third-party software packages, you may have to create print pipes on the host. The RTEL software provides this functionality by providing a UNIX named-pipe interface.
To recreate the RTEL source files:

Printing on the ETS
Table 5-1. TCP Troubleshooting
Area to Check Explanation
The ETS IP address and name are entered in the host file.
Telnet to the ETS using the name in the host file and verify that the ETS name is resolvable and that the ETS is reachable via the network.
Jobs that appear in the host queue reach the ETS
From within the LPC administrative utility, enter these commands to clear and reset the host queue: abort queue clear queue enable queue start queue

The EZWebCon configuration software is the easiest way to configure the ETS. The following sections cover print configuration methods for NetWare hosts.
This chapter explains creating NDS print queues with NetWare Administrator and with the PCONSOLE Quick Setup option. To create NDS print queues, you must be running NetWare version 4.x with NDS capabilities.
If you are running NetWare versions 2.x, 3.x, or version 4.x with bindery emulation, you may configure bindery print queues using QINST (bindery only) or PCONSOLE. For more information, see the NetWare chapter of the Device Server Reference Manual located on the CD-ROM.
Lantronix Terminal and Print Servers support Novell's NDPS for printing using the Novell NDPS Gateway. For instruction on setting up NDPS, refer to your Novell documentation. Lantronix also provides information on setting up NDPS in our FAQs on our support web site (http://www.lantronix.com/support).
Obtain an NDS License If you wish to create NDS print queues, you must read and complete an NDS registration form via one of the following methods:
Using a forms-capable Internet browser, navigate to the Lantronix World
Wide Web site (www.lantronix.com), go to the Technical Support section, and find the Novell NDS Registration link.
Send email to support@lantronix.com. You will receive a blank registration
form that can be completed and returned to Lantronix.
If you don’t have Internet access, contact a Lantronix technical support
representative for assistance. Contact information is provided in A:Contact Information.
Configure your ETS 1. License NDS on your ETS using the string obtained from Lantronix.
Figure 6-1. Licensing NDS
Local>> DEFINE PROTOCOL NETWARE DSLICENSE licensestring

Figure 6-2. Defining Directory Service Tree
Local>> DEFINE PROTOCOL NETWARE DSTREE foodco Note: For an explanation of the structure of the NetWare Directory Service tree, see your host documentation.
Figure 6-3. Defining Directory Service Context
Local>> DEFINE PROTOCOL NETWARE DSCONTEXT ou=kiwi.ou=exotic.o=fruit 4. Enter the List Protocol NetWare Access command to ensure that at least one of the file servers in the directory service tree is in the access list.
Figure 6-4. Defining Access List
Local>> DEFINE PROTOCOL NETWARE ACCESS fileserver 6. Reboot the ETS.
Figure 6-5. Rebooting
Local>> INITIALIZE DELAY 0
The NetWare Administrator management utility allows you to manage network resources, such as queue-based print services, in a tree structure. You can either use the Quick Setup option or individually create printing-related objects.
To create a print queue with the Quick Setup option:
For example, if your file server is mapped to the F: drive, you would use the F: prompt.
NetWare Configuration

The print server name (ETS_xxxxxx),
The new printer name (service name, such as ETS_xxxxxx),
The new print queue name, and
The print queue volume (the name of the file server from which the printer
receives print requests).
The remaining fields can be left in their default settings. 5. Press the F10 key to save the print queue information.
Table 6-1. NetWare Host Troubleshooting (Bindery Mode)
Area to Check Explanation
The print server names in PCONSOLE match the ETS name and its service name
Use PCONSOLE to check.
The ETS NetWare access table
Use the Show Protocols NetWare Access command. Scanning too many file servers can cause a delay between jobs. Configure the access list to only scan for jobs on the file servers of interest.
Table 6-2. NetWare Host Troubleshooting (NDS)
Area to Check Explanation
The ETS NetWare access table
Use the Show Protocols NetWare Access command. By default, only local file servers are scanned for queues.
The ETS login password and the queue password on the file server
The passwords must match or the ETS will not be able to log into the file servers to scan for jobs.
The ETS has successfully attached to the queue
Type NETSTAT at the Local> prompt. This will display information about fileservers, printers, and queues that the ETS has found. If a queue is in JobPoll, the ETS has successfully attached to the queue.
NetWare Configuration

Area to Check Explanation
The DSTree, DSContext, and DSLicense
Type Show Protocol NetWare NDS. This command shows the tree and the context that you have configured, a failure code, and an NDS error code for each server. DSTree is the directory service tree on which the ETS is located. DSContext is the context where the ETS is located; it must match the context on the file server (The DSContext must be of the following form: ou=fruit.o=exotic). DSLicensed should be yes.
Printer and queue changes have propagated through the NDS tree
It may take a few minutes for the changes to propagate. If the ETS doesn’t attach, reboot the ETS.
Table 6-3. NDS Errors from the File Server
0xfffffda7 Object could not be found in the given context
Check the ETS server name, DScontext, and DStree to ensure the printer server is set up correctly with PCONSOLE.
0xfffffda5 Requested attribute could not be found
Use PCONSOLE to ensure that the ETS has associated printers and the printers have associated queues.
0xfffffd69 DS Database is locked
An administrator is probably updating the database. Wait a few minutes and issue the Set Protocol NetWare Reset command.
0xfffffd63 Invalid password The password for the print server object under PCONSOLE must match the ETS login password. If the login password on the ETS is left as the default (access), there should be no password for the print server object.
0xfffffd54 Secure NCP violation
Turn down the NCP packet signature level so that it is not required.
Table 6-4. NDS Errors from the File Server
1 Server out of memory
Turn the ETS off, wait a few seconds, and turn it back on. Disable unused protocols and/or remove fileservers without print queues from the NetWare access list.
2, 3 Unexpected response from file server
Report the problem to Lantronix Technical Support.
4 No printers found for the ETS
Ensure that there are printers for the ETS, and the printer names match the service names on the ETS.
5 No printer queue found
Ensure that the printers have associated queues.
6 Login failed Ensure there is a print server object configured with the same name as the ETS.
NetWare Configuration · Code Meaning Remedy · Bit Meaning Remedy

7 Authentication failed Ensure the ETS login password is the same as the print server object password. If the ETS is using the default password (access), there should be no print server object password.
NetWare Configuration · Bit Meaning Remedy

The EZWebCon configuration software is the easiest way to configure the ETS. The following sections cover print configuration methods for LAT hosts.
To use LAT you must obtain a LAT license from your dealer or Lantronix and use the Set/Define Protocol LAT License command on your ETS. LAT print queues can be created by printing to a port or printing to a service. Printing directly to a port requires no ETS configuration.
Figure 7-1. Creating LAT Application Port
$ RUN SYS$SYSTEM:LATCP LATCP> CREATE PORT LTAnnn/APPLICATION LATCP> SET PORT LTAnnn/NODE=ETS_xxxxxx/PORT=Port_n LATCP> EXIT 2. Create and start a print queue that uses the LAT application port.
Figure 7-2. Creating and Starting Print Queue
$ INITIALIZE/QUEUE/START/ON=LTAnnn:/PROCESSOR=LATSYM /RETAIN=ERROR queue_name 3. Add the commands to the SYS$MANAGER:LAT$STARTUP.COM file so the required LAT devices will be recreated after each host reboot.
Figure 7-3. Printing to Queue
$ PRINT/QUEUE=queue_name filename.txt
By default, the LAT error message codes on the host are not translated into text error messages. If a LAT job fails and appears in the queue with an eight-digit hex result code, the code can be translated by issuing the following commands:

Figure 7-4. Translating LAT Error Codes
$ SHOW QUEUE/FULL/ALL queue_name (note the error code nnnnnnnn) $ SET MESSAGE SYS$MESSAGE:NETWRKMSG.EXE $ EXIT %Xnnnnnnnn
Table 7-1. Troubleshooting LAT Configurations Using a Port
Area to Check Explanation
The specified node name matches the ETS node name
Use the Show Server command to verify.
The specified port name matches the port’s name
Use the List Port 1 command to verify.
Table 7-2. Troubleshooting LAT configurations Using a Service
Area to Check Explanation
The unit is licensed for LAT To use LAT you must obtain a LAT license from your dealer or from Lantronix. Then enter the Define Protocol LAT License string command on your ETS.
The specified node name matches the ETS node name
Use the Show Server command.
The service name used matches the configured service name
Use the Show Service Local Characteristics command.
The service is available Use the Show Service Local Characteristics command from a network login. If the service rating is zero, the serial port is in use.
The LAT characteristic has been enabled on the service
Use the Show Service Local Characteristics command from a network login.
The LAT symbiont is specified as the queue process on the VMS host
Use the VMS command Show Queue/Full queue_name to see the queue characteristics.
For DCPS: there is a bidirectional path to the printer and the printer is locked into PostScript mode
Lock the printer in PostScript mode and issue the Test Service PostScript Count n command. This command sends a job to the printer and waits for the response.
LAT Configuration

The EZWebCon configuration software is the easiest way to configure the ETS. The following sections cover print configuration methods for AppleTalk hosts.
Printing from a Macintosh is only possible with a PostScript printer and bi-directional communication between the ETS and that printer. The ETS supports the Bitronics interface, an extension to the standard Centronics interface. Printers that support Bitronics allow bi-directional communication. To enable Bitronics on an ETS port, use the Define Port 2 Bitronics Enabled command.
Before attempting to print from a Macintosh, ensure that AppleTalk and PostScript are both enabled on at least one service. Once a PostScript AppleTalk service is configured, the service will appear in the Chooser as a LaserWriter in the same zone as the ETS. Select the service in the Chooser and complete the appropriate setup options. Then close the Chooser window and print a test page of text to the Macintosh service.
If there is a router on the network, the ETS will appear in the default zone specified by the router. To change the default zone use the Define Protocol AppleTalk Zone command.
If the ETS is attached to a network without an AppleTalk router, all AppleTalk devices (including the ETS) will appear in the default zone in the Chooser.

Table 8-1. AppleTalk Host Troubleshooting
Area to Check Explanation
The printer is available to be selected in the Chooser
Make sure the printer is in the right zone.
Lock the printer in PostScript mode and issue the Test Service PostScript Count n command. This sends a job to the printer and waits for the response.
AppleTalk Configuration · Bidirectional communication

The EZWebCon configuration software is the easiest way to configure the ETS. This chapter explains DLC/Digital Network Port configuration for Windows NT 4.x hosts.
Printing using an LPD client is the preferred method for sending print jobs to the ETS. Windows 95 does not support DLC printing (see 5:Printing on the ETS for more information).
ETS Configuration To use the DLC protocol, you must have one service with the DLC characteristic enabled.
Figure 9-1. Enabling DLC
Local>> DEFINE SERVICE ETS_xxxxxx DLC ENABLED
Host Configuration To send print jobs from a Windows NT host to the ETS, add the ETS as a Windows NT printer.

If you are experiencing an error that is not described in this book, or if you are unable to fix the error, you may:
To check our online knowledge base or send a question to Technical
Support, go to http://www.lantronix.com/support
Email us at support@lantronix.com.
Call us at:
(800) 422-7044 Domestic (949) 453-7198 International (949) 450-7226 Fax
Our phone lines are open from 6:00AM - 5:30 PM Pacific Time Monday through Friday excluding holidays.
Technical Support Europe, Middle East, and Africa Phone: +49 (0) 89 31787 817 Email: eu_techsupp@lantronix.com or eu_support@lantronix.com
Firmware downloads, FAQs, and the most up-to-date documentation are available at: www.lantronix.com/support
When you report a problem, please provide the following information:
Your name, and your company name, address, and phone number
Lantronix ETS model number
Lantronix ETS serial number
Software version (use the Show Server command to display)
Network configuration, including the information from a Netstat command
Description of the problem
Debug report (stack dump), if applicable
Status of the unit when the problem occurred (please try to include
information on user and network activity at the time of the problem).

This appendix discusses how to diagnose and fix errors quickly yourself without having to contact a dealer or Lantronix. It will help to connect a terminal to the serial port while diagnosing an error to view any summary messages that are displayed.
When troubleshooting, always ensure that the physical connections (power cable, network cable, and serial cable) are secure.
Table B-1. Error Messages
Power-up diagnostic failure (hardware failure)
A. Make sure the Ethernet network cable is properly connected and reboot the ETS. B. If option A fails to resolve the problem, reload Flash ROM. Refer to D:Updating Software.
Problem situations and error messages are listed in Table B-2. If you cannot find an explanation for your problem, try to match it to one of the other errors.
Table B-2. Error Messages
The ETS is connected to a power source, but there is no LED activity.
The unit or its power supply is damaged.
Contact your dealer or Lantronix Technical Support for a replacement.
The ETS is unable to complete power-up diagnostics.
This generally indicates a hardware fault. One of the LEDs will be solid red for three seconds, followed by one second of another color.
The ETS completes its power-up and boot procedures, but there’s no noticeable serial activity.
There is a problem with the serial connection or the set- up of the serial device.
Check the terminal setup and the physical connections, including the cable pinouts (see C:Pinouts). Try another serial device or cable, or cycle power on the ETS.
Message Diagnosis/Remedy · Problem/Message Error Remedy

A rapidly-blinking OK LED may signal boot failure.
Reboot the unit. When the ETS is running normally, the OK LED blinks every two seconds.
The terminal shows a Boot> prompt rather than a Local> prompt.
The ETS is not connected properly to the Ethernet.
Ensure that the ETS is firmly connected to a functional and properly-terminated network node.
The ETS Ethernet address is invalid.
The ETS Ethernet address is located on the bottom of the unit. Use the Set Hardware command to set the correct address, then reboot. See Entering Commands at the Boot Prompt on page 50.
Init Noboot command was entered.
See Entering Commands at the Boot Prompt on page 50.
The ETS passes power- up diagnostics, but attempts to download new Flash ROM code from a network host. If you did not request a TFTP boot, the flash ROM code is corrupt. The unit will remain in boot mode.
If the OK LED blinks rapidly, the Flash ROM code may be corrupt.
Reboot the unit. If you get the same message, you will need to reload Flash ROM. Refer to D:Updating Software.
Table B-3. DHCP Troubleshooting
Area to Check Diagnosis/Remedy
DHCP is enabled on the ETS
Use the Set Server DHCP Enabled command. If you manually enter an IP address, DHCP is automatically disabled.
Make sure the DHCP server is operational.
Check to see that the DHCP server is on and is functioning correctly.
The ETS gets its IP address from the DHCP server
Refer to the DHCP Manager on your DHCP server for information about addresses in use. If the DHCP server doesn’t list your ETS IP address, there may be a problem.
If the BOOTP request is failing and you have configured your host to respond to the request, check these areas:
Table B-4. BOOTP Troubleshooting
Area to Check Explanation
BOOTP is in your system’s /etc/services file
BOOTP must be an uncommented line in /etc/services.
Troubleshooting · Problem/Message Error Remedy

Area to Check Explanation
The ETS is in the loadhost’s /etc/hosts file
The ETS must be in this file for the host to answer a BOOTP or TFTP request.
The download file is in the correct directory and is world-readable
The download file must be in the correct directory and world-readable. Specify the complete pathname for the download file in the BOOTP configuration file, or add a default pathname to the download filename.
The ETS and host are in the same IP network
Some hosts will not allow BOOTP replies across IP networks. Either use a host running a different operating system or put the ETS in the same IP network as the host.
Table B-5. RARP Troubleshooting
Area to Check Explanation
The ETS name and hardware address in the host’s /etc/ethers file
The ETS name and hardware address must be in this file for the host to answer a RARP request.
The ETS name and IP address in the /etc/hosts file
The ETS name and IP address must be in this file for the host to answer a RARP request.
The operating system Many operating systems do not start a RARP server at boot time. Check the host’s RARPD documentation for details, or use the ps command to see if there is a RARPD process running.
If the Boot> prompt appears on the serial console instead of the Local> prompt, one of two things may be wrong. Either the ETS does not have enough information to boot, or the network or flash boot has failed. If pressing the Return key does not display a prompt, press any other key. The Boot> prompt should appear.
If the ETS does not have enough information to boot, or the network or flash boot has failed, it will print a message to the console and wait ten seconds for serial port activity. If it detects no serial port activity, it will continue booting provided the flash is good. However, if the user presses a key during that time period, the ETS will display the Boot> prompt.
A series of commands called Boot Configuration Program (BCP) commands can be entered at the Boot> prompt to configure the ETS. These commands are a subset of the entire ETS command set. For example, a typical TCP/IP configuration might use the following commands:
Troubleshooting

Figure B-1. BCP Command Examples
Boot> SET IPADDRESS 192.0.1.229 Boot> SET SOFTWARE /tftpboot/ETS*.SYS Boot> SET LOADHOST 192.0.1.188 Boot> SET SECONDARY 192.0.1.22 Boot> FLASH % Initialization begins in 5 seconds These commands set the Server’s address, the software loadfile, and the loadhost’s IP address (as well as that of a backup loadhost). The server then reboots using the Flash command and will attempt to load the file ETS*.SYS from the host at 192.0.1.188.
Flush NVR This command is used to restore the ETS’ non-volatile RAM to its factory default settings. It will reset everything that is configurable on the server, including the unit’s IP address.
Flash This command will force the ETS to download new operational code and reload it into Flash ROM. This is necessary when a new version of software is released and you wish to upgrade your unit. If the server cannot download the file, the code in Flash ROM will still be usable.
Help Displays a one-page summary of available commands and what they do.
Init 451 Reboots the ETS after it has been configured. If the ETS can find and load the specified software loadfile, it will restart itself with full functionality. If the loadfile is not found, the server will attempt to reload continuously. If there is an error, or if the console’s Return key is pressed, the ETS will re-enter the Boot Configuration Program.
SET BOOTP {Enabled, Disabled} Enables or disables the sending of BOOTP queries during the boot sequence. It is enabled by default.
SET DHCP {Enabled, Disabled} Enables or disables the sending of DHCP queries during the boot sequence. It is enabled by default.
SET Hardware xx-xx-xx Specifies the last three numbers of the server’s Ethernet address. The first three numbers will be supplied automatically.
The Ethernet address should have been set at the factory. Setting an incorrect address could cause serious network problems.
SET IPAddress ip_address Specifies this server’s IP address. Uses the standard numeric format.
SET Loadhost ip_address Specifies the host to attempt to load the file from. The IP address should be in standard numeric format (no text names are allowed).
Troubleshooting

SET RARP {Enabled, Disabled} Enables or disables the sending of RARP queries during the boot sequence. It is enabled by default.
SET Secondary ip_address Specifies a backup loadhost. The IP address should be in standard numeric format (no text names are allowed). The backup loadhost will be queried if the primary host cannot load the server.
SET Software filename Specifies the name of the file to load. The ETS will automatically add .SYS to the filename you specify. Note that all protocols must have a filename specified (either the default or set by the user). For more information, see D:Updating Software.
TCP/IP users must use the Software option to specify the loadhost, the loadfile, and their own network address.
TFTP users can specify a complete path name (up to 31 characters) if the file is located in a directory other than the default. The case of the filename must match that of the filename loaded onto the host computer.
Show Server Use this command when issuing other commands to view the current ETS setup.
Troubleshooting

Figure C-1. RJ45 Ethernet Connector

ETS servers are RS-423 compliant, and are thus limited by the equipment at the remote end of the serial line. If the port is connected to an RS-232 device, it is subject to RS-232 limits: 15m (50 ft.) in length at 9600 baud, and to 2m (6 ft.) at 115.2K baud, although longer lengths will generally work.
Figure C-2. RJ45 Serial Connector

RJ45 to DB25 If you are connecting an RJ45 port to a DTE device (such as a terminal) that has a DB25 connector, you will need to use an RJ45-DTE DB25 adapter. To connect an RJ45 port to a DB25 connector on a DCE device, you will need an RJ45-DCE DB25 adapter. The pinout information for both connections is shown in Figure C-3.

Figure C-3. Pinouts of RJ45-DB25 Connections


The arrows in Figure C-3 represent the direction of the signal. The pinouts assume that the 8-conductor cable connecting the ETS and the adapter block is a swapped/ rolled serial cable. Both the transmit and receive ground signals on the ETS connector are wired to the signal ground on a DB25 adapter.
Figure C-4. RJ45 to DCE DB25 Adapter

You can use a crimper block to connect both transmit and receive grounds from the RJ45 cable to the single signal ground on the DB25. The connector internally “splices” the two wires together and provides one wire into the DB25 connector as shown below.
Pinouts

Figure C-5. Wire Splicer

To splice the wires, cut off the end of the wire that does not extend through the connector and insert both wires into the connector. Make sure that the wire that does not extend through the connector is in as far as possible to ensure a solid connection. Make sure that the wire that does extend through the connector extends far enough on the other side to be inserted in to the DB25 connector. Carefully squeeze the connector using a pair of pliers to make sure it is fully latched.
Figure C-6. RJ45-DTE DB9 Adapter

The arrows in Figure C-6 represent the direction of the signal. The pinouts assume that the 8-conductor cable connecting the ETS and the adapter block is a swapped\rolled serial cable. Both the transmit and receive ground signals on the ETS connector are wired to the signal ground on a DB9 adapter.
The information about crimping the RJ45 ground wires in RJ45 to DB25 applies to the DB9 connector as well.
Pinouts

Lantronix intends to provide multiple software files for the ETS models. Each software file will contain the core ETS operating code for that particular model.
Table D-1. Available ETS Software
Software File Name Models Supported
ETS.SYS Old, do not use this file
ETS16PR.SYS ETS16PR
ETS32PR.SYS ETS32PR
Obtaining Software
Current software files (ETS*.SYS) are available on the distribution CD. You can obtain software updates and release notes for the ETS from the Lantronix World Wide Web site (www.lantronix.com), or by using anonymous FTP through the Internet (ftp.lantronix.com).
Via the Web The latest version of ETS*.SYS can be downloaded from the Lantronix Web site: http://lantronix.com/support/download/index.html
Via FTP The ETS software resides on the Lantronix FTP server (ftp.lantronix.com). Most of these files are binary data, so the binary option must be used to transfer the files. All released files are in the pub directory. Always download the README file in the pub directory before downloading anything else; it contains a list of available software files.
To log into the FTP server, enter a username of anonymous and enter your full email address as the password. The following text will be displayed:

Figure D-1. Sample FTP Login
230-Welcome to the Lantronix FTP Server. 230- 230-IMPORTANT: Please get the README file before proceeding. 230-IMPORTANT: Set BINARY mode before transferring executables. 220- 230-Direct questions to support@lantronix.com or 800-422-7044 (US) 230- 230 Guest login ok, access restrictions apply. Remote system type is [your type will be displayed here]. ftp>
The ETS stores software in Flash ROM to control the initialization process, operation, and command processing. The contents of Flash ROM can be updated by downloading a new version of the operational software via NetWare, TCP/IP, or MOP. Regardless of which protocol is used to update Flash ROM, the following points are important:
The Flash ROM software file name, ETS*.SYS, should not be changed.
The download file should be world-readable on the host.
There is a sixteen character length limit for the path name.
There is a twelve character limit for the filename.
Define commands must be used because Set configurations are cleared
when the ETS boots. Use the List Server Boot command to check settings before rebooting. Note: It is important to check ETS settings before using the Initialize Reload command to ensure that you are reloading the correct software file.
Reloading Sequence If DHCP, BOOTP, or RARP is enabled on the ETS, the ETS will request assistance from a DHCP, BOOTP, or RARP server before starting the download attempts. The ETS will then try TFTP, NetWare, and MOP booting (in that order) provided that it has enough information to try each download method.
Downloading and rewriting the Flash ROM will take approximately two minutes from the time the Initialize command is issued. If the download file cannot be found or accessed, the ETS can be rebooted with the code still in Flash ROM. The OK/ACT LED will blink quickly while the ETS is booting (and reloading code) and then slowly when it returns to normal operation.
TCP/IP Before the ETS downloads the new software, it will send DHCP, BOOTP, and/or RARP queries (all are enabled by default). Next, the ETS will attempt to download the ETS*.SYS file using TFTP (Trivial File Transfer Protocol).
If a host provides DHCP, BOOTP, or RARP support, it can be used to set the ETS IP address (all methods) and loadhost information (BOOTP and RARP only).
Updating Software

Some BOOTP and TFTP implementations require a specific directory for the ETS*.SYS file. See your host’s documentation for instructions.
To manually configure the ETS IP parameters for software reload, use the following commands.
Figure D-2. Configuring TCP/IP Reload
Local> SET PRIVILEGED Password> SYSTEM (not echoed) Local>> DEFINE SERVER IPADDRESS nnn.nnn.nnn.nnn Local>> DEFINE SERVER SOFTWARE “/tftpboot/ETS*.SYS” Local>> DEFINE SERVER LOADHOST nnn.nnn.nnn.nnn Local>> LIST SERVER BOOT Local>> INITIALIZE RELOAD Note: For instructions on how to log into the ETS to enter these commands, see the Getting Started chapter.
The path and filename are case-sensitive and must be enclosed in quotation marks. When attempting to boot across an IP router, you must configure the router to proxy- ARP for the ETS, or use the bootgateway feature. For more information, see Set/Define Bootgateway in the Commands chapter of the Device Server Reference Manual located on the CD-ROM.
NetWare The ETS*.SYS file should be placed in the login directory on the NetWare file server. The ETS cannot actually log into the file server (since it knows no username/password); it can only access files in the login directory itself. On the ETS, specify the file server name, filename, and path.
Figure D-3. Configuring NetWare Reload
Local> SET PRIVILEGED Password> SYSTEM (not echoed) Local>> DEFINE SERVER NETWARE LOADHOST fileserver Local>> DEFINE SERVER SOFTWARE SYS:\LOGIN\ETS*.SYS Local>> INITIALIZE RELOAD
MOP The ETS*.SYS filename is the only parameter that the ETS needs to reload via MOP. Make sure the service characteristic is enabled on the host's Ethernet circuit, copy the ETS*.SYS file to the MOM$LOAD directory, and reload the ETS using the Initialize Reload command. Be sure to use binary mode for the file transfer.
Updating Software

Many of the problems that occur when updating the Flash ROM can be solved by completing the following steps:
Table D-2. Flash ROM Troubleshooting
Area to Check Explanation
Ensure the file is in the login directory. Since the ETS cannot actually log into the file server, it has very limited access to the server directories.
Check the file and directory permissions.
Ensure the loadhost name and address are specified correctly and that their case matches that of the filenames on the host system.
Ensure the file and pathnames are enclosed in quotes to preserve case.
Ensure that TFTP is enabled on the host; several major UNIX vendors ship their systems with TFTP disabled by default.
The Ethernet circuit must have the service characteristic enabled. MOP
Ensure that the MOM$LOAD search path includes the directory containing the ETS*.SYS file.
Updating Software · NetWare

Rapid temperature changes may affect operation. Therefore, do not operate the ETS near heating or cooling devices, large windows, or doors that open to the outdoors.
If operating the ETS above 2.4 km (8000 ft.), decrease the operating temperature rating by 1° F for each 1000 ft.

This appendix lists some of the most frequently-used commands of the Multiport Device Server command set. More information about the command set, including additional options, can be found in the Device Server Reference Manual located on the CD-ROM and available for download from http://lantronix.com/support/download/index.html
Please note the following before continuing:
Commands are divided into Server (general), Port, and Protocol sections.
Within each section, commands are listed alphabetically.
Commands may require privileged user status. Enter Set Privileged, then
enter the privileged password when prompted.
When you enter a Define (or Purge) command, you must reboot the ETS for
the command to take effect. Alternately, you can issue several Set commands and then a Save command to make the Set commands take effect without rebooting.
When the abbreviated syntax “{EN/DIS}” is shown, you must choose either
Enabled or Disabled to complete the command.
When 2 is shown as the port number, enter a single port number, a list of
port numbers separated by commas, a range of port numbers separated by dashes, or the word all.
Table F-1. Frequently-used Server Commands
servicename Makes a connection to a LAT service.
LOCAL num Makes a connection to the specified local port.
RLOGIN host Makes an Rlogin connection to the specified host (text name or numeric IP address).
TCP host Makes a raw TCP connection to the specified host (text name or numeric IP address).
TELNET host Makes a Telnet connection to the specified host (text name or numeric IP address).
DEFINE SERVER BOOTP {EN/DIS} Enables or disables querying for a BOOTP host at system boot time.
DEFINE SERVER DHCP {EN/DIS} Enables or disables querying for a DHCP host at system boot time.
Command Option(s) Description · CONNECT option

DEFINE SERVER GATEWAY ipaddr Specifies the host to be used as a TCP/IP gateway to forward packets between networks. Enter an IP address.
DEFINE SERVER INCOMING option
BOTH Enables incoming LAT and Telnet connections.
LAT Enables only incoming LAT connections.
NONE Disables incoming connections.
TELNET Enables only incoming Telnet connections.
PASSWORD Causes the ETS to prompt for a password for all incoming connections.
NOPASSWORD Allows connections to be established without prompting for a password.
DEFINE SERVER IPADDRESS ipaddr Sets the ETS’ network IP address.
DEFINE SERVER LOADHOST ipaddr Specifies the TCP/IP host from which the ETS requests its run-time code.
DEFINE SERVER LOGIN PASSWORD Sets a new password that will be required before incoming logins are accepted. You will be prompted for the new password (up to 6 alphanumeric characters, case-insensitive).
DEFINE SERVER NAME “newname” Specifies a new name for the ETS. Names are restricted in length; generally a name of 11 or fewer characters is permissible. Enclose value in quotes to maintain case sensitivity.
DEFINE SERVER NETWARE LOADHOST server
Specifies the NetWare host from which the ETS requests its run-time code. Enter a file server name of up to 11 characters.
Sets a new password that will be required for privileged user status. You will be prompted for the new password (up to 6 alphanumeric characters, case-insensitive).
DEFINE SERVER RARP {EN/DIS} Enables or disables querying for a RARP host at system boot time.
DEFINE SERVER SOFTWARE “filename”
Specifies the name or path (TCP) of the software download file. The filename can be up to 11 characters, and the pathname can be up to 26. The ETS will add a “.SYS” extension.
DEFINE SERVER SUBNET MASK ipmask
Specifies the subnet mask to be used for the ETS. The ipmask must be in n.n.n.n format.
Displays a list of top-level (general) Help topics. HELP option
Displays information about the keyword(s) entered. Multiple keywords must be specified in the order they occur in a command.
DEFINE SERVICE “name” PORT num Creates a new service and associates it with the specified port.
DEFINE SERVICE “name” option
Toggles whether the named service can be used to service networks running the specified protocol. RTEL applies to TCP/IP networks.
LAT {EN/DIS}
NETWARE {EN/DIS}
Frequently-Used Commands · Command Option(s) Description

DEFINE SERVICE “name” option
DLC {EN/DIS} Specifies which service will handle print requests from DLC hosts. DLC can be enabled on one service per ETS.
When Enabled, causes the ETS to print a banner page before jobs.
BINARY {EN/DIS} When Enabled, the ETS will not process data passed through the service. This characteristic should be enabled when printing PCL data.
EOJ string Causes the ETS to send an end-of-job string to the attached device after every job. Enter an end string or the word none.
When Enabled, causes the ETS to append a formfeed to the end of LPR print jobs.
When Enabled, causes the ETS to assume the attached device is a PostScript device and act accordingly.
When Enabled, causes the ETS to place a PostScript wrapper around each job.
SOJ string Causes the ETS to send a start-of-job string to the attached device before every job. Enter a start string or the word none.
DEFINE SERVICE “name” option
TCPPORT string Specifies a raw TCP listener socket for the service. Enter a socket number (4000 to 4999) or the word none.
Specifies a TCP listener socket for the service. Unlike TCPport, this option performs Telnet IAC interpretation on the data stream. Enter a socket number (4000 to 4999) or the word none.
DELAY num Schedules a reboot after num minutes. Enter a value from 0 to 120.
CANCEL Cancels an impending initialization.
FACTORY Reboots the ETS to its factory default settings.
NOBOOT Forces the ETS to stop in Boot Configuration Mode rather than fully rebooting.
RELOAD Forces the ETS to download new operational code and reprogram its flash-ROM.
Logs out the current port (the port that issued the command). LOGOUT option
PORT num Logs out the specified port.
LOCAL Removes the definitions of all local services. PURGE SERVICE option “service” Removes the definition of the specified service.
SET PRIVILEGED Enters privileged mode, provided the user enters the proper privileged password when prompted.
{SHOW/MONITOR} QUEUE Displays the status of ETS queues once (Show) or continually every three seconds (Monitor).
Displays ETS information once (Show) or continually every three seconds (Monitor).

COUNTERS Displays characteristics related to the various counters kept by the ETS.
Displays characteristics about all configured services once (Show) or continually every three seconds (Monitor).
“service” Displays only characteristics related to the named service.
ALL Zeroes all port, node, and server counters. ZERO COUNTERS option PORT num Zeroes port counters for the specified port.
In the following commands, “2” can be a single port number, a list of port numbers separated by commas, a range of port numbers separated by dashes, or the word all.
Table F-2. Frequently-used Port Commands
DEFINE PORT 2 ACCESS option
DYNAMIC The port can initiate and receive connection requests.
LOCAL The port can initiate connection requests, and local logins are permitted.
NONE The port is unusable.
REMOTE The port can receive host-initiated connection requests.
DEFINE PORT 2 CHARACTER size Toggles the port between 7-bit and 8-bit characters (the default). Enter either 7 or 8.
When Enabled, the port will be logged out automatically whenever DSR is de-asserted.
DEFINE PORT 2 DTRWAIT {EN/DIS} When Enabled, the ETS will not assert DTR on the port when it is idle (no user logins or connections).
DEFINE PORT 2 FLOW option
CTS Specifies CTS/RTS (hardware) flow control.
{EN/DIS} Activates or deactivates the currently-configured flow-control method.
NONE Removes the current flow control settings.
XON Specifies XON/XOFF (software) flow control.
DEFINE PORT 2 NAME “newname” Enter a name of up to 16 alphanumeric characters for the specified port.
DEFINE PORT 2 PARITY option
parity Enter even, odd, mark, or space. Specifying mark or space will change the character size to 7 bits.
NONE Specifies that no parity will be used (the default).
DEFINE PORT 2 SPEED baudnum Sets the port’s baud rate. Acceptable baudnum values range from 300 to 230000 baud.

{SHOW/MONITOR} PORT 2 Displays the port’s configuration characteristics once (Show) or continually every three seconds (Monitor). Counters and Status keywords can be added.
Sends an ASCII data stream to the port for the specified number of rows and/or columns. TEST PORT 2 option
COUNT rows WIDTH cols
POSTSCRIPT Sends a PostScript test page to the port.
In the following table, PROTO is an abbreviation for the optional keyword PROTOCOL.
Table F-3. Frequently-used Protocol Commands
{EN/DIS} Enables or Disables the AppleTalk protocol for the ETS. DEFINE PROTO APPLETALK option
ZONE newzone Places the ETS in a zone other than the default.
DEFINE PROTO IP option
{EN/DIS} Enables or Disables the TCP/IP protocol for the ETS.
GATEWAY ipaddr See DEFINE SERVER GATEWAY ipaddr.
See DEFINE SERVER IPADDRESS ipaddr.
LOADHOST ipaddr See DEFINE SERVER LOADHOST ipaddr.
Specifies the IP address of the host that will resolve text host names into their numeric equivalents for TCP/IP connection attempts.
DEFINE PROTO LANMAN option
{EN/DIS} Enables or Disables the LAN Manager protocol for the ETS.
{EN/DIS} Enables or Disables the LAT protocol for the ETS. DEFINE PROTO LAT option
LICENSE string Enables LAT on multi-port ETS device servers. Enter the license string obtained from Lantronix.
DEFINE PROTO NETWARE option
{EN/DIS} Enables or Disables the NetWare (IPX) protocol for the ETS.
Configures the NetWare Directory Services context in which the ETS is located. For more information about NDS contexts, see your NDS documentation.
DSLICENSE string Configures the NetWare Directory Services license needed to enable NDS on your ETS. Enter the license string obtained from Lantronix.
DSTREE string Configures the NetWare Directory Services tree in which the ETS is located. For more information about NDS trees, see your NDS documentation.
DEFINE PROTO NATIVE Configures the ETS to use the “native mode” frame format.

NETWARE ENCAPSULATION option {EN/DIS}
ETHER_II Configures the ETS to use Ethernet v2 frame format.
802_2 Configures the ETS to use 802.2 frame format with NetWare SAPs.
SNAP Configures the ETS to use 802.2 frame format with SNAP SAPs.
DEFINE PROTO NETWARE LOADHOST server
See DEFINE SERVER NETWARE LOADHOST server.
ALL Removes the entire IP security table. PURGE IPSECURITY option ipaddress Removes entries from the IP security table that are related to the specified IP address.
ALL Removes all entries from the NetWare access list. PURGE PROTO NETWARE ACCESS option server Removes entries from the NetWare access list that are related to the specified file server.
{SHOW/MONITOR} PROTO protocolname Displays operating characteristics of the specified protocol.
Frequently-Used Commands · Command Option(s) Description

(according to ISO/IEC Guide 22 and EN 45014)
Electromagnetic Emissions: EN55022: 1998 (CISPR 22, Class A: 1993, A1 1995, A2: 1996) IEC 1000-3-2/A14: 2000 IEC 1000-3-3: 1994
Electromagnetic Immunity: EN55024: 1998 Information Technology Equipment Immunity Characteristics IEC 6100-4-2: 1995 Electro-Static Discharge Test IEC 6100-4-3: 1996 Radiated Immunity Field Test IEC 6100-4-4: 1995 Electrical Fast Transient Test IEC 6100-4-5: 1995 Power Supply Surge Test IEC 6100-4-6: 1996 Conducted Immunity Test IEC 6100-4-8: 1993 Magnetic Field Test IEC 6100-4-11: 1994 Voltage Dips & Interrupts Test (L.V.D. Directive 73/23/EEC)
Supplementary Information: The product complies with the requirements of the Low Voltage Directive 72/23/EEC and the EMC Directive 89/336/EEC.
Manufacturer’s Contact: Director of Quality Assurance, Lantronix 15353 Barranca Parkway, Irvine, CA 92618 USA Tel: 949-453-3990 Fax: 949-453-3995

Compliance and Warranty Information
Lantronix warrants each Lantronix product to be free from defects in material and workmanship for a period of ONE YEAR. During this period, if a customer is unable to resolve a product problem with Lantronix Technical Support, a Return Material Authorization (RMA) will be issued. Following receipt of a RMA number, the customer shall return the product to Lantronix, freight prepaid. Upon verification of warranty, Lantronix will -- at its option -- repair or replace the product and return it to the customer freight prepaid. If the product is not under warranty, the customer may have Lantronix repair the unit on a fee basis or return it. No services are handled at the customer's site under this warranty. This warranty is voided if the customer uses the product in an unauthorized or improper way, or in an environment for which it was not designed.
Lantronix warrants the media containing its software product to be free from defects and warrants that the software will operate substantially according to Lantronix specifications for a period of 60 DAYS after the date of shipment. The customer will ship defective media to Lantronix. Lantronix will ship the replacement media to the customer.
In no event will Lantronix be responsible to the user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss of equipment, plant or power system, cost of capital, loss of profits or revenues, cost of replacement power, additional expenses in the use of existing software, hardware, equipment or facilities, or claims against the user by its employees or customers resulting from the use of the information, recommendations, descriptions and safety notations supplied by Lantronix. Lantronix liability is limited (at its election) to:
Refund of buyer's purchase price for such affected products (without
interest).
Repair or replacement of such products, provided that the buyer follows the
above procedures. There are no understandings, agreements, representations or warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose, other than those specifically set out above or by any existing contract between the parties. Any such contract states the entire obligation of Lantronix. The contents of this document shall not become part of or modify any prior or existing agreement, commitment or relationship.
For details on the Lantronix warranty replacement policy, go to our web site at http://www.lantronix.com/support/warranty/index.html