Precautions
THE FCC REGULATION WARNING (for U.S.A.) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Location Using the unit in the following locations can result in a malfunction.
Power supply Please connect the designated AC/AC power supply to an AC outlet of the correct voltage. Do not connect it to an AC outlet of voltage other than that for which your unit is intended.
Interference with other electrical devices Radios and televisions placed nearby may experience reception interference. Operate this unit at a suitable distance from radios and televisions.
Handling To avoid breakage, do not apply excessive force to the switches or controls.
CE mark for European Harmonized Standards CE mark which is attached to our company’s products of AC mains operated apparatus until December 31, 1996 means it conforms to EMC Directive (89/336/EEC) and CE mark Directive (93/68/EEC). And, CE mark which is attached after January 1, 1997 means it conforms to EMC Directive (89/336/EEC), CE mark Directive (93/68/ EEC) and Low Voltage Directive (73/23/EEC). Also, CE mark which is attached to our company’s products of Battery operated apparatus means it conforms to EMC Directive (89/336/ EEC) and CE mark Directive (93/68/EEC).
Care If the exterior becomes dirty, wipe it with a clean, dry cloth. Do not use liquid cleaners such as benzene or thinner, or cleaning compounds or flammable polishes.
Keep this manual After reading this manual, please keep it for later reference.
Keeping foreign matter out of your equipment Never set any container with liquid in it near this equipment. If liquid gets into the equipment, it could cause a breakdown, fire, or electrical shock. Be careful not to let metal objects get into the equipment. If something does slip into the equipment, unplug the AC/AC power supply from the wall outlet. Then contact your nearest Korg dealer or the store where the equipment was purchased.
This product has been manufactured according to strict specifications and voltage requirements that are applicable in the country in which it is intended that this product should be used. If you have purchased this product via the internet, through mail order, and/or via a tele- phone sale, you must verify that this product is intended to be used in the country in which you reside. WARNING: Use of this product in any country other than that for which it is intended could be dangerous and could invalidate the manufacturer’s or distributor’s warranty. Please also retain your receipt as proof of purchase otherwise your product may be disqualified from the manufacturer’s or distributor’s warranty.
![Page 2 of the Korg TP-2 user manual — TP-2 [ Tube Preamp ]](/cdn/reader/f7/f7e861ca4531adc0d71e96afa766a8642008b6bf47b5062b3453bf75d85e173d/images/page-2.webp?w=400)
Input connectors: XLR-3-31 type (+48 V phantom power, switchable), 1/4” TRS phone jack (balanced / unbalanced is Hi-Z)
Input impedance: 4 k (XLR-3-31), 10 k (TRS phone Jacks), 1 M (TRS phone Jacks is Hi-Z)
Nominal level: +4 dBu
–34 dBu to +14 dBu @ TRIM=max. — min PAD ON
Maximum level: –48 dBu to 0 dBu @ TRIM=max. — min PAD OFF –22 dBu to +26 dBu @ TRIM=max. — min PAD ON
– 48 dBu to 0 dBu @ TRIM=max. — min PAD OFF – 22 dBu to +12 dBu @ TRIM=max. — min PAD ON
Dimensions:
224(W) x 170(D) x 88(H)mm / 8.82”(W) x 6.69”(D) x 3.46”(H) (including protrusions)
Frequency response:
10 Hz - 44 kHz ±1 dB @ output +4 dBu, 10 k load
AC/AC power supply, Owner’s manual
![Korg TP-2 — TP-2 [ Tube Preamp ] diagram (page 2)](/cdn/reader/f7/f7e861ca4531adc0d71e96afa766a8642008b6bf47b5062b3453bf75d85e173d/images/fig-2-1.webp)

If you are using a guitar or the line output from an instrument, connect it to the TRS phone jack.
Thank you for purchasing the Korg TP-2 Dual Tube Preamp w/ Optical Compression and Digital Output. In order to enjoy long and trouble-free use, please read this owner’s manual carefully, and use your TP-2 only as directed.
Balanced phone plug Unbalanced phone plug
Features
The TP-2 is a dual-channel preamp featuring two 12AX7 vacuum tubes, plus fast operating and transparent optical compression and limiting circuitry. Designed to accept a variety of sources over a wide range of levels, it is ideal for your most critical and demanding recording applications. In addition to both XLR and 1/4” TRS balanced outputs, the TP- 2 also features both optical and coaxial digital outputs (S/P DIF format) allowing it to interface with other digital equipment, or to serve as a stand alone AD converter. Using a specially tuned version of our acclaimed Valve Force circuit, the TP-2 delivers the robust, musical warmth and mid- low region presence typical of vacuum tubes. The optical compression responds quickly and transparently, providing a distinctly full analog body without adversely coloring the sound. In addition, the optical compressor’s gain reduction and limiting circuitry allow you to avoid any audio clipping while you’re recording.
If a condenser mic is connected or disconnected with the phantom power switch on, damage to your equipment may occur. For this reason, always turn the phantom power switch off before connecting or disconnecting a condenser mic.
14 15 16 17 18

Place the unit horizontally so that the level meters operate correctly.
The level meters indicate the level of the signal before it is sent to the output level faders.
1/4" TRS phone jack
XLR jack

2-2. Adjusting the input level When you’ve finished making your connections, watch the TP- 2’s level meter while you use the gain trim knob to adjust the level. Set the trim knob so that the level meter needle does not exceed 0 dB when the loudest sound is input. If the level meter goes beyond 0 dB even when the gain trim knob is turned all the way toward the left, press the PAD switch and then use the gain trim knob to adjust the level.
When the fader is at the 0 dB position, the meter level will match the output level.
Normally if the needle goes beyond 0 dB, digital clipping has oc- curred, causing distortion. You should set the level so that it does not exceed 0 dB.
2-3. Using the compressor Turn the compressor sensitivity knob all the way to the left so that the compressor is not being applied. Use the gain trim knob to raise the level so that the meter slightly exceeds 0 dB during the loudest input passages. Slowly turn the compressor sensitivity knob toward the right. The gain reduction LED will begin to light, indicating that the compressor is being applied. While watching the level meter, continue turning the compressor sensitivity knob until the level does not exceed 0 dB during the loudest input passages. If you want to apply a lot of compression to intentionally “squash” a vocal, use the gain trim knob to raise the input level further, and turn the compressor sensitivity knob toward the right to increase the compression.
By using the gain trim knob to raise the preamp level appropriately, you can saturate the vacuum tube, generating analog overtones to enrich the sound in conjunction with the compressor.
2-4. Using the link switch Turn on the link switch if you want to use stereo compression. When you’re recording a stereo source, and the level of one channel rises to the point where compression is being applied to only that one channel, then the relative volume of the other channel will increase, producing the impression that the stereo image has shifted to one side. In such cases, turning on the link switch will automatically apply compression to both channels at the same time, whenever either channel reaches the compressor’s threshold level. So that the compressors for both channels will function in the same way, select the same compressor mode setting for both channels (either Fast or Slow). You should also set the compres- sor sensitivity knob to about the same setting for both channels.
First connect the AC/AC power supply to the TP-2’s AC9V connec- tor, and then plug it into an electrical outlet.
Start by connecting your external equipment. Connect the AC/AC power supply. If you will be using the digital output, set the sampling frequency select switch to the correct frequency for your other gear, and then turn on the power.
Before turning on the power, set the output level faders to – so that sudden loud noise does not occur.

This device contains vacuum tubes. We recommend that you allow the tubes to warm up for about ten minutes after you turn on the power, before you begin running any audio signals through the TP-2. If you begin using this device immediately after turning on the power, this may cause malfunctions and/or shorten the life of the vacuum tubes. In order to maximize reliability, avoid placing this device above or below heat-producing equipment such as a power amp.
to the AC outlet to digital input devices to a mixer or HDR
Do not attempt to remove, replace or change the tubes in the TP-2. The tubes are not a user serviceable part.
Vacuum tubes generate heat. Do not allow your skin to contact the vacuum tube cover for an extended period of time. Doing so can cause low-temperature burns.