Instruction/ maintenance manual of the product 153.332960HA Kenmore
Go to page of 44
Owners Manual FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MOBILE HOMES MODEL NUMBERS: 153.332861 40 Gal. L.R 153.332870HA 40 Gal. High Altitude L.E 153.332880 50 Gal. L.R 153.332890HA 50 Gal. High Altitude L.E 153.332960 40 Gal.
Safety Precautions AWARNING J Improper installation, adjustment, alteration, service or maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manu- J al for assistance or consult your local Sears Service Center for further information.
Safety Precautions (cont'd) AWARNING A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such a closet, unless you provide air as shown in the "Facts to Consider About the Location" sec- tion.
Safety Precautions (cont'd) &WARNING Minimum clearances between the water heater and com- bustible construction are 0" at the sides and rear, 5" at the front, and 0" from the vent pipe. Clearance from the top of the jacket is 12".
Table of Contents e c_L__oa, cty Precautions ........................................................................................................................................... .2-4 Table of Contents ...........................................
Customer Responsibilities • -rl l _r lnanK xou for purchasing a Sears water heater. Properly installed and maintained, it should give you years of trouble free ser- vice. If you should decide that you want the new water heater profes- sionally installed by Sears call the local Sears Service Center or any Sears store.
Materials and Basic Tools Needed Materials Needed "Ib simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materi- als, depending on your type of installation.
Installation Instructions Removing the Old Water Heater Q_Iilrn gas supply to water "OFF" the the heater. _WARNING If the main gas line shutoff serving all gas appliances is I used, also shut "off" the gas at each appliance. Leave all gas appliances shut "off" until the water heater installation is complete.
Installation Instructions (cont'd) Facts to Consider About the Location You should carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance.
Installation Instructions (cont'd) Facts to Consider About the Location (cont'd) AWARNING This water heater must not be installed directly on carpeting. Carpeting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the appliance by at least 3 inches (76.
Installation Instructions (cont'd) • LESS THAN 120" POWER VENT J TERMINAL 12" rain. Figure 3a I FORCED AIR INLET VENT TERMINAL f 18" TO WALL OR OTHER J_lS" MIN. _ OBSTRUCTIONS THAT MAY INTERFERE WFTH VENTING. VENT TERMINAL Figure 3b I CORNER OF BUILDING POWER VENTTERMINAL _js -- ".
Installation Instructions (cont'd) Combustion Air and Ventilation for Appliances Located in Unconfined Spaces Unconfined Space is a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour of the aggregateinput rating of all appli- ances installed in that space.
Installation Instructions (cont'd) Water Piping *A WARNING HOTTER WATER CAN SCALD: Water heaters are intended to _roduce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact.
Installation Instructions (cont'd) Temperature-Pressure Relief Valve AWARNING At the time of manufacture this water heater was provided with a combination temperature-pressures relief valve certi.
Installation Instructions (cont'd) Filling the Water Heater A CAUTION J Never use this water heater unless it is completelyfired with J water. To prevent damageto the tank, the tank must be filled with water. Water must flow from the hot water faucet before turn ng ON gas to the water heater.
Installation Instructions (cont'd) Wiring (cont'd) USE WITHOUT POWER CORD (cont'd) 3. A standard 7_" conduit opening has been made in the water heater junction box for the conduit connection. 4. Use wire nuts and connect the power supply wiring to the wires inside the water heater's junction box.
Installation Instructions (cont'd) Venting _WARNING To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be uti- lized. Any additions of other gas appliances on vent with this water heater will adversely affect the oper- ation of the water heater.
Installation Instructions (cont'd) Venting (cont'd) ALL MODELS _ OPTIONAL 2" VENT PIPING 2" PVC, ABS or CPVC Schedule 40 vent piping: 1. A wire screen to fit a 2" PVC, ABS or CPVC Schedule 40- 45 ° vent cap is supplied with the water heater.
Installation Instructions (cont'd) 3 ELBOW EXAMPLE MIN. RISE Y;" PER FIVE FEET MIN. RISE Y¢' PER FIVE FEET ALL MODELS- VENTING THROUGH WALL OPTIONAL 2 °" VENT PIPING 2" DIA.VENT MAX. LENGTH (FT.) 5O 45 4O 35 3O 25 NUMBER OF 90 ° DEG.
Installation Instructions (cont'd) Venting (cont'd) VENTING THROUGH AN OUTSIDE WALL WITH LOW GROUND CLEARANCE 1. When the vent piping cannot pass through an outside wall at a height greater than or equal to 12" above the ground (or above snow accumulation level), then the installation can be modified as shown below.
Installation Instructions (cont'd) APPROXIMATE SETTING TIME FOR 2" TO 3" PIPE JOINTS MOVEMENT COMPLETE OF JOINT SET 90°F to 150°F % hr.
Installation Instructions (cont'd) Venting (cont'd) VENTING THROUGH A ROOF ALL MODELS 3 "° PVC, ABS or CPVC Schedule 40 vent piping: 1.
Installation Instructions (cont'd) ALL MODELS -- THROUGH ROOF 3 °" DIA.VENT MAX. LENGTH (FT.) 115 II0 105 100 95 9O NUMBER OF 90 ° DEG. ELBOWS • I 2 3 4 5 6 ALL MODELS m THROUGH ROOF OPTIONAL 2" VENT PIPING 2" DIA.VENT MAX. LENGTH {FT.
Installation Instructions (cont'd) Gas Piping (cont'd) ,&WARNING The appliance and its individual shutoff valve must be disconnected from the gas supply piping sys- tem during any pressure testing of the gas system at test pressures in excess of I/2 pound per square inch (3.
Installation Instructions (cont'd) Installation Checklist BEFORE OPERATING: • Check the gas lines for leaks• a. Use a soapy water solution• DO NOT test for gas leaks using a match or open flame. b. Brush the soapy water solution on all gas pipes, joints and fittings• c.
Operating Instructions This water heater is equipped with an electrically operated vent- ing system and electronic control. For the burner to come on, the water heater thermostat must call for heat. Then the system will begin sequencing, each section proving itself before gas is allowed to flow to the burner.
Operating Instructions (cont'd) Operating AWARNING BEFORE OPERATING [PROPANE (L.P.) GAS WATER HEATERS]: Propane (L.P.) gas is heavier than air. Should there be a leak in the system, the gas will settle near the ground.
Operating Instructions (cont'd) _[,_WARNING:lfyoudonotfollowtheseinstructionsexactiy, afireor_ explosion may result causing property damage, personal injury or loss of life. BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATER AND AIR PURGED FROM ALL LINES.
Operating Instructions (cont'd) Temperature Regulation Short repeated heating cycles caused by small hot water uses can cause temperatures at the point of use to exceed the thermostat set- ting by up to 30°E If you experience this type of use you should consider using lower temperature settings to reduce scald hazards.
Service and Adjustment Tank (Sediment) Cleaning Sediment build-up on the tank bottom may create varying amounts of noise, and if left in the tank will cause premature tank failure. Sediment deposits can usually be removed by draining and flushing the tank with water.
Service and Adjustment (cont'd) Temperature-Pressure Relief Valve Operation Drain Valve Washer Replacement The temperature-pressure relief valve must be manually operated at least once a year.
Troubleshooting Guide Start Up Conditions THERMAL EXPANSION Water supply systems may, because of such events as high line pressure, frequent cut-off}, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc.
Troubleshooting Guide (cont'd) Operational Conditions CONDENSATION Whenever the water heater is filled with cold water, a certain amount of condensation will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensation.
Troubleshooting Guide (cont'd) Operational Conditions (cont'd) VENTING MANUAL RESET SWITCH There is a venting manual reset switch located on the draft hood. If the switch is activated, it will not reset itself_ Before resetting this switch, check for flue blockage and propriety of the venting system.
Troubleshooting Guide (cont'd) Leakage Checkpoints Use this guide to check a "Leaking" water heater. Many suspect- ed "Leakers" are not leaking tanks.
Troubleshooting Guide (cont'd) _,WARNING J This troubleshooting guidehas been supplied for use by quali-J fled servicepersonnel who have a complete understanding of both e ectrictic andgas. _i CAUTION J Label all wiring before disconnecting any wiring; to ensure J correct reconnection.
Troubleshooting Guide (cont'd) SYSTEMS CHECK Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician. _,WARNING DO NOT BY-PASS ANY CONTROLS TO MAKE HEATER OPERATE. OPERATE ONLY AS WIRED FROM FACTORY.
Troubleshooting Guide (cont'd) I;,] ;T+] :]II :1 _ I [I¢_'Te_] = [,,_+] ILej d[e] _.l NOT ENOUGH HOT WATER VENT PIPE TOO HOT (ABOVE 17O°F) YELLOW FLAME CONDENSATION WATER LEAKS LEAKING T&a.
Notes 39.
Parts Order List THE ECONOMIZER TM 6 POWER VENT GAS WATER HEATER MODEL NUMBERS: 153.332861 40 Gal. L.P. 153.332870HA 40 Gal. High Altitude L.E 153.332880 50 Gal.
Parts Order List (cont'd) THE ECONOMIZER TM 6 POWER VENT GAS WATER HEATER MODEL NUMBERS: 153.332861 40 Gal. L.P. 153.332870HA 40 Gal. High Altitude L.
Parts Order List THE ECONOMIZER TM 6 POWER VENT GAS WATER HEATER MODEL NUMBERS: 153.332960 40 Gal. 153.332970HA 40 Gal. High Altitude 153.332980 50 Gal.
Parts Order List (cont'd) THE ECONOMIZER TM 6 POWER VENT GAS WATER HEATER MODEL NUMBERS: 153.332960 40 Gal. 153.332970HA 40 Gal. High Altitude 153.
FULL ONE YF_R WARRANTY ON WATER HEKFER For one year from the date of purchase, when your Sears Kenmore water heater is installed and operated in a single-family residence in accordance with the instructions in this manual, Sears will: 1. Repair defects in material or workmanship in this water heater, free of charge.
An important point after buying a device Kenmore 153.332960HA (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Kenmore 153.332960HA yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Kenmore 153.332960HA - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Kenmore 153.332960HA you will learn all the available features of the product, as well as information on its operation. The information that you get Kenmore 153.332960HA will certainly help you make a decision on the purchase.
If you already are a holder of Kenmore 153.332960HA, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Kenmore 153.332960HA.
However, one of the most important roles played by the user manual is to help in solving problems with Kenmore 153.332960HA. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Kenmore 153.332960HA along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center