CUST OM P AST A ™ SYSTEM GAS SER VICE MANU AL KEEP THIS MANU AL FOR TRAINING NEW PERSONNEL 1-800-KEA TING www .keatingofchicago.com ON OFF 100° 2 2 0 ° O F F 200° 1 2 0 ° 1 4 0 ° 1 6 0 ° 1 80 ° 100° 2 2 0 ° O F F 200° 1 2 0 ° 1 4 0 ° 1 6 0 ° 1 80 ° P I L O T T O L I T E 3 0 S E C .
i T his operating, inst allation, and service manual should be given to the user . The operator of the Pasta System should be familiar with the functions and operation of the cooker . This manual must be kept in a prominent, easily reac hable location near the Past a System.
T ABLE OF CONTENTS SECTION I INTRODUCTION General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 S tandard Features . . . . . . . . . . . . . . . . . . . . . . . . . .1 Model V ariations . . . . . . . . . . . . . . . . . . . . . .
I INTRODUCTION GENERAL Keating Pasta Gas Systems are designed to give maximum production efficiency , delivering high quality food products. The following design features are incorporated in Keating Pasta Gas Systems.
l Y ou must maintain this appliance free and clear from combustibles. l Y ou must maintain the following minimum clearances from combustible and noncombustible construction: l Adequate clearance for servicing and proper operation must be maintained. Y our Pasta System is designed to be serviced from the front.
IF NOT INST ALLED, OPERA TED AND MAINT AINED IN ACCORDANCE WITH THE MANUF ACTURER’S INSTRUCTIONS, THIS PRODUCT COULD EXPOSE YOU TO SUBST ANCES IN FUEL OR IN FUEL COMBUSTION WHICH CAN CAUSE DEA TH OR SERIOUS ILLNESS AND WHICH ARE KNOWN T O THE ST A TE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.
4 Figure 2-1 RESTRAINING DEVICES On Pasta System inst allations with casters, casters and jam nuts must be completely tightened. Adequate means must also be provided to limit the movement of the appliance without depending on the connector , the quick-disconnect device or its associated piping to limit the appliance movement.
5 A 3 / 4 " IPS manual gas valve is shipped with each single Pasta System for field inst allation. Batteries have a factory installed manual gas valve for each Past a System.
6 Constructional changes to the area where the Pasta System is installed shall not af fect the air supply to the Pasta System. The installation, st art-up and changes required when changing from one gas type to another can be performed only by a certified professional.
2. T urn “On” main power On/Off switch (located between the amber and green indicating lights). 3 . Light the constant pilot (located next to lef t burner as you face it).
1. T urn off Pasta System and open the door . Figure 3-3 Drain, drain valve and overflow tubing 2. Slowly turn handle. The drain valve will be completely open after 1 / 4 turn. CLEANING When cleaning and boiling out your Pasta System, use white vinegar and Keating Klenzer to keep your Pasta System in top condition.
B. How to program the “Keating” Electronic Timer l The Keating Electronic T imer is programmable to four different timer ranges with two dif ferent alarm modes for each time range.
10 PREVENTIVE MAINTENANCE Preventive maintenance should be done in daily , weekly , monthly and yearly intervals as necessary . Following preventive maintenance procedures will help keep your Pasta System working ef ficiently . Proper care and servicing will lead to years of quality performance.
in the tube on the right side of the overflow deck. The upper sensor controls the water level and the lower sensor controls the low water safety shut-off system. Once the water On/Off switch is turned on, the blue light will come on and start to fill until the water level reaches the upper sensor .
12 PROBLEM PROBABLE CAUSE SOLUTION Constant pilot won’t light. a. Gas isn't turned on. b. Clogged constant pilot tubing. c . Constant pilot valve isn't turned on. a. T urn manual gas valve on. If using flexible connector with quick disconnect, make sure quick disconnect is completely engaged.
13 PROBLEM PROBABLE CAUSE SOLUTION Flames come out front. a. Burners misaligned. b. Exhaust problems. c. Radiants have slipped forward. d. Flue blockage. a. Adjust position of burners. b. Install deflector to block down draf t. Install or adjust flue restrictors.
14 PROBLEM SOLUTIONS (Follow Sequentially) W ater always filling. a. Clean sensors thoroughly with brush and vinegar . b. Adjust the sensitivity of the B Board (for the top sensor) fully clockwise. c. If filling persists, ground out the top sensor (if filling stop s, replace sensor – Part #010212).
15 REPLACEMENT OF A AND B BOARDS 1. Locate the wiring diagram. it will help later with connecting wires to the board. 2. Disconnect wires from the board. 3 . Unscrew mounting screws. There are three of them per board. 4. Replace the board. 5. Reconnect the wires.
16 CUSTOM P AST A ™ SYSTEM CONTROL P ANEL WITH DIGIT AL TIMERS VII P ARTS LISTS ORDERING P ARTS P arts may be ordered by p art number by calling Keating at 1-800-KEA TING or your service company . Y ou may also order online at the Keating Parts S tore, www .
17 ITEM DESCRIPTION QUANTITY P ART NUMBER 1 TOGGLE SWITCH - PILOT ON 1 004507 2 INDICA TING LIGHT , AMBER - PILOT ON 1 031624 3 TOGGLE SWITCH – MAIN ON-OFF 1 004501 4 INDICA TING LIGHT , GREEN - SEC.
18 GAS P AST A SYSTEM ASSEMBL Y I ITEM DESCRIPTION MODELS P ART# 14 18 20 24 1 GAS V AL VE, 120V ALL NA TURAL GAS 004269 1 1 1 1 LP 008123 1 1 1 1 2 RUNNER PILOT TUBE SEE BELOW 1 1 1 1 3 CONST ANT PILOT ASSEMBL Y ALL (1.
19 ITEM DESCRIPTION MODELS P ART# 14 18 20 24 22 RADIANT , 2 - FINS ALL 000041 3 4 4 5 23 BURNER 008264 2 2 2 3 BURNER CM 004088 2 24 SECONDAR Y BURNER ALL 004088 1 2 2 2 25 SECONDAR Y GAS SOLENOID AL.
20 P AST A SYSTEM WIRING DIAGRAM.
21 GAS P AST A SYSTEM WITH BASKET -LIFT WIRING DIAGRAM.
L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp ® , Custom Pas.
K EA TI N G LI M ITE D W AR RANTY C AR D PLEASE COMPLETE AND MAIL A T ONCE–WARRANTY IS NOT IN EFFECT UNTIL CARD IS RETURNED COMP ANY : _______________________________________________________________.
An important point after buying a device Keating Of Chicago Custom Pasta Gas System 0107 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Keating Of Chicago Custom Pasta Gas System 0107 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Keating Of Chicago Custom Pasta Gas System 0107 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Keating Of Chicago Custom Pasta Gas System 0107 you will learn all the available features of the product, as well as information on its operation. The information that you get Keating Of Chicago Custom Pasta Gas System 0107 will certainly help you make a decision on the purchase.
If you already are a holder of Keating Of Chicago Custom Pasta Gas System 0107, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Keating Of Chicago Custom Pasta Gas System 0107.
However, one of the most important roles played by the user manual is to help in solving problems with Keating Of Chicago Custom Pasta Gas System 0107. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Keating Of Chicago Custom Pasta Gas System 0107 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center