INSTRUCTIONS

This illustration shows the KM-H3000E/U Multi Format Digital Production Switcher

Thank you for purchasing this JVC product. Before operating this device, please read the instructions carefully to ensure the best possible performance.
For Customer Use: Enter the Model and Serial number of your unit. Retain this information for future reference.

Before using this product and any associated equipment, refer to the "Important Safety Instructions" listed below so as to avoid personnel injury and to prevent product damage. Products may require specific equipment, and /or installation procedures be carried out to satisfy certain regulatory compliance requirements. Notices have been included in this publication to call attention to these Specific requirements.
Read these instructions. Keep these instructions. Heed all warning. Follow all instructions. Do not use this apparatus near water. Unplug system from the wall outlet before cleaning. Clean only with a dry cloth. Do not block any ventilation openings. Install in accordance with manufacturer's instructions. Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. Only use attachments/accessories specified by the manufacturer. Unplug this apparatus during lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer that have the same characteristics as the original part. Unauthorized substitutions may result in fire, electric shock, or other hazards. Upon completion of any service or repairs to this product, ask the service technician to perform routine safety checks to determine that the appliance is in safe operating condition. Do not expose this apparatus to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the apparatus. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious injury to a child or adult, and serious damage to the product. Use only with a cart or stand recommended by the manufacturer, or sold with the product. Wall or shelf mounting should follow the manufacturer's instructions, and should use a mounting kit approved by the manufacturer. A product and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the product and cart combination to overturn. To completely disconnect this apparatus from the AC Mains, disconnect all power supply cord plugs from the AC receptacles. The mains plug of the power supply cords shall remain readily operable.
Warning — The safe operation of this product requires that a protective earth connection be provided to the product's power supply adapters. A grounding conductor in the supply cord provides this protective earth. To reduce the risk of electrical shock to the operator and service personnel, this ground conductor must be connected to an earthed ground. This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supplied to your home, consult your dealer or local power company. Do not overload wall outlets and extension cords as this can result in fire or electric shock. Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
Warning — This product includes an "Ethernet Port" which allows this product to be connected to a local area network (LAN). Only connect to networks that remain inside the building. Do not connect to networks that go outside the building. Important information related to the safety and compliance operation of this apparatus is identified on the product's name plate label, located on the bottom of the product. Please refer to this label prior to operating, this product.

CANADA
This Class "A" digital apparatus complies with Canadian ICES-003.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Cet appareil numerique de la classe "A" est conforme a la norme NMB-003 du Canada.
Symbol Meanings:
This unit should be used with 12V DC only.
This symbol on the equipment refers you to important operating and maintenance (servicing) instructions within the Product Manual Documentation. Failure to heed this information may present a major risk of damage or injury to persons or equipment.
Ce magnétoscope ne doit être utilizé que sur du courant direct en 12V.
ESD Susceptibility - This symbol is used to alert the user that an electrical or electronic device or assembly is susceptible to damage from an ESD event.
This equipment is in compliance with the essential requirements and other relevant provisions of CE Directive 93/68/EEC.
FCC Part 15 Subpart B
This equipment has been tested and found to comply with the limits for a class A Digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This equipment has been tested to CISPR 22:1997 along with amendments A1:2000 and A2:2002 and found to comply with the limits for a Class A Digital device.
Due to design modifications, data given in this instruction book are subject to possible change without prior notice.
Dear Customer, This apparatus is in conformance with the valid European directives and standards regarding electromagnetic compatibility and electrical safety. European representative of Victor Company of Japan, Limited is:
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
JVC Technical Services Europe GmbH Postfach 10 05 04 61145 Friedberg Germany
This unit should be used with 12 V DC only.


FOR EUROPE This equipment is in conformity with the provisions and protection requirements of the corresponding European Directives. This equipment is designed for professional video appliances and can be used in the following environments: - Controlled EMC environment (for example, purpose-built broadcasting or recording studio), and rural outdoors environments. In order to keep the best performance and furthermore for electromagnetic compatibility we recommend to use cables not exceeding the following lengths:

All product names in this manual are trademarks or registered trademarks of their respective companies. Marks such as ™, ® and © are not used in this manual. Issue 1F
Information for Users on Disposal of Old Equipment [Eurpean Union]
Attention: This symbol is only valid in the European Union. This symbol indicates that the electrical and electronic equipment should not be disposed as general household waste at its end-of-life. Instead, the product should be handed over to the applicable collection point for the recycling of electrical and electronic equipment for proper treatment, recovery and recycling in accordance with your national legislation. By disposing of this product correctly, you will help to conserve natural resources and will help prevent potential negative effects on the environment and human health which could otherwise be caused by inappropriate waste handling of this product. For more information about collection point and recycling of this product, please contact your local municipal office, your household waste disposal service or the shop where you purchased the product. Penalties may be applicable for incorrect disposal of this wasted, in accordance with national legislation. (Business Users) If you wish to dispose of this product, please visit our web page www.jvceurope.com to obtain information about the take-back of the product. [Other Countries outside the European Union] If you wish to dispose of this product, please do so in accordance with applicable national legislation or other rules in your country for the treatment of old electrical and electronic equipment.
This symbol indicates the environmental protection period is 10 years according to the China RoHS Directive. When all safety precautions and user instructions in the manual are followed, this product presents no harmful environmental pollution, effects to humans, or property for the specified period commencing from the manufacturing date. This period was derived from the safety use time limit method. The environmental protection use period of the product and the articles of consumption are: All components: 10 years.



The KM-H2500 and KM-H3000 combine professional switcher quality with an easy to use and mobile design. They can be used with other JVC professional products to create professional style broadcasts.
equipped with additional source buttons, key control buttons, and a positioner for additional control of wipes and patterns.
Before operating your switcher, please read this manual carefully and store it in a safe and accessible place for future reference.
This manual is designed to familiarize the user with switcher layout, menu navigation, basic and advanced operation.
Several switcher functions are customizable. When using this manual, consider your requirements and style when adjusting items that involve colors, patterns, and effects. The manual provides instructions on how to adjust these items but you can tailor their use to your production requirements.

The following abbreviations are used throughout the manual:
The KM-H3000 and KM-H2500 control panels offer similar functionality. The KM-H3000 control panel is
Figure 1 KM-H3000 · Figure 2 KM-H2500


There are two ways to access the menu system:
IN 1 IN 2 IN 3 IN 4 IN 5 IN 6 IN 7 IN 8 IN 9 IN 10 IN 11 IN 12
To access a menu using the MENU button:
AUX 1 AUX 2 AUX 3 PV PGM1 PGM2 ANLG

IN 1 IN 2 IN 3 IN 4 IN 5 IN 6
AUX 1 AUX 2 AUX 3 PV PGM1 PGM2 ANLG

The buttons illuminate to indicate one of four states:
Auto-follow displays the menu for a selected function when the button for that function is pressed. Auto-follow is always active — when you press any button on the control panel that has a corresponding menu, the menu is automatically displayed.
Some menus have multiple pages. When the NEXT button is lit, multiple menu pages exist. Press NEXT to move to the next menu page. Press and hold NEXT and then press MENU to move to the previous menu page.
Some menus contain sub-menus. Press the knob corresponding to the sub-menu to access it. Press and hold the NEXT button and then press the RECALL button to return from the sub-menu.
If you wish to return to the first page of a top-level menu, Press and hold the NEXT button and then press the STORE button.
Insert films can be installed into most switcher buttons. Insert films allow you to name specific source buttons, control buttons, or replace the default button names with those of a different language.
All inserts must be cut to the dimensions indicated for small (1) or large (2) buttons. Using insert films that do not meet the recommended criteria may damage the button cap and diffuser.
The control panel has three continuously rotatable pushbutton knobs located below the display screen. The knobs are used to select and alter menu options.
0.444"
0.468"
To use the knobs:

0.504"
0.528"
Figure 5 Insert Sizing
To install switcher button inserts:
To default a value using the knobs:
Auto-Follow

The Fader is used to manually perform a wipe or dissolve transition. Move the Fader handle from one limit to the other to perform a transition.
The progress of the transition is shown on the Progress Bar to the left of the Fader handle. As the Fader handle moves from one limit to the other, the Progress Bar indicates the progress of the transition.
CUT
The KM-H3000 has a joystick positioner for positioning wipes, patterns, and washes. The KM-H2500 does not have a positioner.
Functions such as mattes, and Panel Glow have options for adjusting the appearance of a selected color. Individual adjustments for colors are:
Luminance affects the brightness of the video signal. Increasing luminance gives a brighter color while decreasing luminance gives a darker color.
Hue controls the shade of color (red, yellow, green, blue, etc.).
Shift
Saturation affects the vividness of a color. Increasing saturation produces a more vivid color while decreasing saturation produces a less vivid color. Fully decreasing the saturation produces gray.
Shifting allows access to the secondary sources for each source button.
To shift a bus and access the secondary sources:



This chapter describes how to configure your switcher to meet your requirements. Setup and switcher personality options are discussed.
The switcher supports both external and internal reference types.
Both versions can operate in both standard and multi-definition video formats.
To set the reference type:
To change the reference video format:


The switcher has four input format converter / frame synchronizer (FCFS) channels that can be used for the following:
There are separate North American and European versions of the switcher.
North American switchers support the following video formats:
Converting between video formats often requires converting between aspect ratios. Your switcher

supports the following aspect ratio conversion methods:
16:9 4:3
Figure 9 Pillar Box Aspect Ratio Conversion

FCFS channels are assigned to either specific inputs or bus-pairs. Each bus-pair requires two FCFS channels. The bus pairs are as follows:
Figure 6 Full Aspect Ratio Conversion
FCFS channels maintain separate settings for different switcher video formats. This lets you change between switcher video formats without losing FCFS channel configurations.

To assign an FCFS channel:

Figure 7 Zoom Aspect Ratio Conversion
4:3 16:9
Figure 8 Letter Box Aspect Ratio Conversion

Configuring FCFS Channels in Input Mode
Input mode locks a specified FCFS channel to a specific input. Table 1 lists the input video formats you can convert to the specified switcher video format.
Configuring FCFS Channels in Bus Mode
Bus mode locks a specified FCFS channel to a specific bus-pair.
Table 1 Format Conversions for Input Mode

Table 2 Format Conversions for Bus Mode

480i / 59.94Hz 480i (aspect ratio conversion), 720p, 1080i / 59.94Hz
480i / 59.94Hz 480i (aspect ratio conversion), 720p, 1080i / 59.94Hz
576i / 50Hz 576i (aspect ratio conversion), 720p, 1080i / 50Hz
576i / 50Hz 576i (aspect ratio conversion), 720p, 1080i / 50Hz
To configure an FCFS channel set to Input mode:

To configure an FCFS channel set to Bus mode:


To set the output reference sync:


The switcher has three reference outputs that can be configured independently.
If you are using one of the output references to time external devices, ensure that they are connected to the appropriate REF OUT 1, REF OUT 2, or REF OUT 3 outputs.
Different applications require different output reference formats and delay settings. Consult a facility engineer for assistance in configuring these settings.

To change the aspect ratio:

You can quickly reset the output reference sync values to the default settings.
To reset the output reference sync values:

Ancillary data is information such as closed captioning or embedded audio. The switcher can be configured to pass this data or strip it from the output video. The following parameters are available:

To configure ancillary data parameters:

The switcher supports both 4:3 and 16:9 aspect ratios when running in the 480/576i video format.

Table 3 Default Alpha Channel Mappings

Many video sources have an associated video source that contains alpha (transparency) information. You must configure the switcher to use the correct alpha source. Once you associate a video and alpha source, they are linked and used for Auto-Select keying.
Alpha sources are designated as shaped or linear (unshaped). Shaped sources convert partial transparency to either fully transparent or fully opaque, giving the video signal well-defined edges.
Linear (unshaped) sources use the full range of transparency in the alpha channel to give smooth transitions between transparent and opaque areas. Use linear if you are unsure which setting to use.
The switcher has the following outputs:
To associate video and alpha inputs:

The analog output allows the switcher to output signals in NTSC and PAL formats. It can be routed from the Preview, Program, or any of the primary inputs. The analog output is not aspect ratio converted. Downconversions from 16:9 HD sources display as 16:9 SD video.
To configure the analog output:


The switcher is equipped with an Ethernet port to allow remote access. By default, the switcher uses DHCP to automatically obtain an IP address. You can manually set an IP address, network mask, and default gateway if your network does not have a DHCP server.
To configure a DHCP IP address for your switcher:
The Clean Feed output provides a second program output that is derived from a different location than the standard program output. Using the Clean Feed allows you to remove particular keys without affecting the primary program output. Typical applications are:

To configure the Clean Feed output:


To configure a static IP address for your switcher:

The switcher has customizable features that allow you to tailor operation to your personal preferences.
You can set the behavior of the Aux buses during a memory recall. The buses can be configured to hold inputs (overriding whatever input is saved in the recalled memory) or to change to the input saved in the recalled memory.
To set the Aux Bus Recall Mode:


Panel buttons are set to a glow color which is used when the button is not selected. This glow color can be customized to your preference.
To customize the Panel Glow color:


To load a custom Panel Glow color scheme:

You can save a custom Panel Glow color scheme so that it may be recalled as needed.
To save a custom Panel Glow color scheme:

The switcher goes into a Power-Save mode after a certain amount of time (20 minutes by default) without user interaction. Touching any control will wake the switcher. Any functionality associated with the touched control is ignored until the unit is active and all lights and display are turned on.
During Power-Save mode, video related hardware is not affected and video signals are still passed through the switcher.
To configure the power-save timeout:

You can load a custom color scheme or one of the preset color schemes that are included on your switcher.

power as possible without affecting on-air video. • Sleep — The menu display turns off. Buttons light and slowly fade in a raindrop pattern.
Resource Sharing
You can select the units used to specify durations for various switcher transitions. Choose the units that you are most comfortable working with.
The switcher can only use one Chroma Key at a time. You can specify how the Chroma Key is shared between the keys on your switcher.
To select the units for switcher transitions:
To specify Chroma Key resource sharing:


You can set the double-press rate of the switcher to suit your preference. Setting a fast rate requires you to double-press the knobs in quick succession in order to be recognized as a double press. Setting a slow rate allows more time between presses but may register two single presses as a double press. Find a value that is most comfortable for your operating style.
To set the switcher double press rate:


To enable or disable external editor control:

The Switch On feature allows you to select when the switcher triggers a transition from one video source to the next when you are running in an interlaced video format. Each interlaced video frame is composed of an odd field and an even field and you can specify that transitions are initiated on:
If you are running in a progressive scan video format, setting your switcher to transition on even or odd fields will cause the switcher to only allow transitions on every second frame.
To set when the switcher initiates transitions:

You can choose the state of the Next Transition area after a transition is performed.
To set the Next Transition area reset behavior:

Transition Resume Direction
Your switcher can be controlled by external editors using the GVG100 protocol. You can enable or disable external control.
You can choose which direction a paused transition proceeds in when it is re-started.

To set the transition resume direction:

You can choose whether a Key remains in the Next Transition area or is removed if a dedicated key transition is performed.
To set the Next Transition Key behavior:



This chapter describes the general operation of your switcher. Basic information is provided to help get you up and running quickly.
Transitions allow you to replace the on-air video source with another source. During a transition, the source you selected on the Preset bus becomes active on the Program bus and the source that was active on the Program bus is now on the Preset bus.
You can perform three types of transitions:
To perform a transition:

Cuts are the simplest transition, performing an instantaneous change between sources. You can perform a cut transition as described in the previous section, or you can perform the transition directly on the Program bus.
This also applies to keys. If a key is on-air, you can select alternate sources on the Key/Aux bus and have them instantly cut on-air.
To cut on the Program bus:


You can control the amount of time a dissolve or wipe transition takes to complete when you press the AUTO TRANS button. Transitions performed with the Fader are not affected.
To change the rate for automatic transitions:
You can pause a dissolve or wipe transition while it is in progress.

To pause and resume a transition in progress:

You can select from a number of predefined patterns and control the amount of time a wipe transition takes to complete.
To select a wipe transition pattern:

Keying allows you to insert portions of one scene into another. Keys appear as overlays over the background image.
The switcher supports three key types:

The KM-H2500 supports 2 keys. The KM-H3000 supports 3 keys.
To perform a key transition:

Video is layered as shown in (Figure 10).

Figure 10 Video Layering
Key transitions are similar to background transitions. You can perform key and background transitions simultaneously.
Selecting a key allows you to configure the key type and select a source for that key.
To select a key:
› AUTO SEL, or CHR KEY — selects Key 1 and sets the key type.
› KEY 2 SEL — selects Key 2.
› KEY 3 SEL — selects Key 3 (KM-H 3000 only).
Key transitions are performed similarly to background transitions. All transition types are available for key transition.
For More Information on selecting keys, refer to the section “Selecting Keys” on page 19.

If an immediate transition is required or an unexpected transition needs to be performed, the switcher allows for a dedicated key transition. Dedicated key transition buttons for this purpose are located to the right of the Fader. Only dissolve transitions can be performed with the dedicated key transition buttons.
To perform a dedicated key transition:

The Chroma Key masks a specified color allowing you to quickly extract a foreground subject from a controlled-color background. The switcher can mask the following colors: blue, green, red, cyan, magenta, and yellow. The default color is blue.
To create a Chroma Key:

You can set the transition rate for the dedicated key transition buttons independently of the other switcher transition rates.
To change the transition rate for dedicated key transitions:


To select a matte color by loading a preset:

A Matte is a solid color signal that is generated by the switcher and can be adjusted for hue, saturation, and luminance. It can also be adjusted for position, size, aspect, border, and softness.
To change the pattern:

Mattes can be a solid color or a wash. A wash fills the matte with one of the 10 patterns.
You can use two methods to select a matte color:
To select a matte color by specifying hue, saturation, and luminosity:

Mattes can also be adjusted by using these modifiers:

The Aspect function allows you to alter the shape of the selected wash pattern. For example, if you want the wash to be oval shaped, select the circular pattern and adjust the aspect ratio until the desired oval is created.
To fade to black:

Borders are effects created around the selected pattern for the wash. The Border function allows you to adjust the appearance of the border.
The Softness function controls the edge of the wash. It is a pattern edge effect produced by mixing key source and key fill signals such that the edge of the pattern can be sharp or blurred.
The Hue 2, Sat 2, and Lum 2 functions control the secondary color. If you are creating a wash and want to add a second color, adjusting these options will generate and modify another color set within the pattern.
To apply other adjustments:

Fade to Black is achieved by selecting the black source and performing a transition.


This chapter describes advanced operating concepts for your switcher. Advanced topics and information on modifying basic concepts to fit your requirements are discussed.
The built-in memory system can store up to 100 switcher memories (10 banks of 10 memory locations). This allows you to save the settings for a later time without having to make the adjustments again.
There are two ways to access the memory system:
To select the memory access mode:

Recalling the memory register allows you to quickly re-use the effect you previously stored.
To recall a setting from a memory register:

Storing settings to a memory register allows you to save an effect for re-use.

The source on the bus you selected will not change when the memory is recalled (the source setting stored in the memory for that bus is ignored).
The switcher can be set so that recalling a memory does not affect what is currently on-air. There are two modes you can choose from:
Enabling Memory AI mode changes the way key elements are recalled. If a key is currently on-air, the element for that key is recalled in the next available off-air key. If there is no available off-air keys, the element is not recalled.
You can choose to have a bus remain unaffected by a memory recall (the selected source on the bus is not replaced with the source stored in the memory).
All resource sharing is set to FLOAT mode so that key elements may be recalled to other keys than originally stored.
To perform a Bus Hold:

Table 4 shows the contents of a memory register and the state of the switcher in various scenarios.
Table 4 Recall to Preview Scenarios

Depending on the Recall to Preview setting, the elements recalled are as follows:
Recall to Preview Off
› Input 3 is recalled to the Program bus (on-air image instantly cuts to Input 3).

› Input 4 is recalled to Key 1 (on-air image instantly cuts to Input 4).
To set the Recall to Preview mode:

› Input 5 is recalled to Key 2 (on-air image not affected as Key 2 is off-air).
› Input 1 is selected on the Preview bus.
› Input 3 is recalled to the Program bus (on-air image instantly cuts to Input 3).
› Input 4 is recalled to Key 1 (on-air image is not affected as Key 1 is off-air).
› Input 5 is recalled to Key 2 (on-air image is not affected as Key 2 is off-air).
› Input 1 is selected on the Preview bus.
Recall to Preview On
› Input 3 is recalled to the Preset bus (on-air image is not affected).
› Input 4 is not recalled to Key 1 as Key 1 is on-air (on-air image is not affected).
› Input 5 is recalled to Key 2 (on-air image is not affected as Key 2 is off-air).
› Input 3 is recalled to the Preset bus (on-air image is not affected).
› Input 4 is recalled to Key 1 (on-air image is not affected as Key 1 is off-air).
› Input 5 is recalled to Key 2 (on-air image is not affected as Key 2 is off-air).
› Input 1 is selected on the Preview bus.
› Input 3 is recalled to the Preset bus (on-air image is not affected).
› Input 4 is recalled to Key 2 as Key 1 is on-air (on-air image is not affected).
You can stop a transition at a preset position between the two Fader limits. With the transition limit enabled, an automatic transition or a transition performed with the Fader will stop when it reaches the defined limit.
› KM-H3000: Input 5 is recalled to Key 3 as Key 2 is now in-use (on-air image is not affected).
› KM-H2500: Input 5 is not recalled as both keys are now in use.
To define the transition limit point:
› Next Transition area is set to transition background, Key 1 off-air, Key 2 on-air, and Key 3 on-air (KM-H3000 only).

› Input 3 is recalled to the Preset bus (on-air image is not affected).
› Input 4 is recalled to Key 1 (on-air image is not affected).
› Input 5 is recalled to Key 2 (on-air image is not affected).
› Next Transition area is set to transition background, Key 1 on-air, and Key 2 on-air.
Memory AI

You switcher is shipped with the following default settings:
The Progress Bar next to the Fader flashes to indicate the defined transition limit.
To perform a transition with a transition limit set:

› 15 frames for 59.94 Hz video formats.
› 13 frames for 50 Hz video formats.
When the transition reaches the defined limit, it will stop.
› 8 frames for 59.94 Hz video formats.
› 7 frames for 50 Hz video formats.
To Quickly Reset the Transition Limit
The transition limit is reset to 50% and the trans limit feature is turned off.
Configuring Default Settings
You can restore the entire switcher or individual settings to default values. Menu items can also be reset.
You can customize any of the default parameters and save them as a user-defined default.
To configure user-defined defaults:
You can also capture the state of the switcher as a user-defined default, allowing you to reset to those settings at any time.


To reset the switcher using an alternate method:
All switcher settings are restored to the default values.
Shared Parameters
You can restore user-defined default settings to a factory state. This is useful if you wish to begin creating a new user-defined default from a known starting configuration.
Some parameters are shared between features and if reset in one area, are reset in all areas that share that parameter. The shared parameters are:
To restore user-defined default settings to the factory state:

You can reset individual settings to default values rather than resetting the entire switcher.
To reset wipes:
To reset dissolves:
To reset Key 2 or 3:
When resetting a key, the selected Chroma Key color and any Split Key assignments are not reset.
Resetting the switcher restores the user-defined default settings..
To reset the switcher:
To reset Aux buses:

To reset the Chroma Key:
To reset an Auto-Select Key:

Saving Memory Banks and Registers
The values for particular parameters can be reset individually. This allows you to restore the default setting if you are unsatisfied with the adjusted values.
You can save up to 9 sets of up to 100 memory registers on a USB drive.
To save memory registers to a USB drive:
Some parameters are shared between features and, if reset in one area, will be reset in all areas that share that parameter.

To reset individual menu items:
You can restore your switcher to the factory default settings. You may wish to do this when troubleshooting problems with your switcher.
Restoring to factory defaults resets the entire switcher. Save any configuration information to a memory register if you wish to re-load it after performing the factory default.
To restore factory defaults:

You can use the USB port to:
These files and settings can be copied and backed-up on a standard computer.

knob to select the memory register on the USB drive you wish to load. • If you selected Bank, use the Local knob to select the memory bank you wish to replace with the loaded data. Use the USB knob to select the bank on the USB drive you wish to load.
Once the memory registers are loaded, you can recall them for use.
To load memory registers from a USB drive:

Software upgrades stored on a USB drive can be uploaded to the switcher.
To upgrade the switcher software:

The menu displays a message indicating the software upgrade is in progress. The Upgrade LED on the rear of the switcher is lit, indicating an upgrade is in progress.

To modify the transparency:

When the software upgrade is complete, the menu displays a message indicating the software upgrade was successful, the Upgrade LED on the rear of the switcher turns off, and the switcher performs an automatic restart.
Once the switcher restarts, it is ready to use. You can safely remove the USB drive.
To apply a mask:

Keys can be modified to give them more distinct qualities and personalize your images.
All key types have the following parameters that can be modified:
The Transparency function allows you to adjust the transparency of the key from completely opaque to completely transparent. As the level of transparency is adjusted, the graphic in the menu changes to represent the current percentage of transparency.
A mask is a keying technique in which a pattern is combined with the key source to block out unwanted portions of the key source. Mask modifiers are:

To modify a mask:
To modify the clip or gain:


Converting Between Shaped and Unshaped Auto-Select Keys
You can convert an unshaped Auto-Select Key to a shaped Auto-Select Key by using the Make Linear function. This defaults any modifiers to the selected key.
To convert an unshaped Auto-Select Key to shaped:
You can control aspects of the Chroma Key using the Chroma Key menus. The following effects can be adjusted:
There are a number of other attributes you can modify to change the mask appearance. Press NEXT and use the knobs to access and change other attributes.
Modifying Clip and Gain for Unshaped Auto-Select Keys
If an Auto-Select key is unshaped, you can also modify clip and gain.
Chroma key adjustments are persistent and are not affected by a soft reset or switcher reboot. However, initializing the Chroma or performing a factory reset returns all adjustments to default values.
The Clip function adjusts the threshold level of the key. Only areas of the source video that are higher than the setting of the threshold cut a hole in the background video.
Using the Edge, Shadow, Gain and Spill Effects
The Edge effect controls the sharpness of the key edge.
Increasing Gain causes the color to become increasingly saturated.
The Shadow effect allows you to include or removed any shadows that are cast on the Chroma Key background.
The Gain effect controls color saturation. Increasing the Gain causes the video signal colors to become
Modifying Other Attributes

increasingly saturated and vivid. Decreasing the Gain decreases the saturation until the image is black and white.
To create a Split Key:

The Spill effect allows you to handle chroma key spill where the background color (the color being removed) spills onto the key object.
To adjust the Edge, Shadow, Gain, and Spill:

You can modify the appearance of a Split Key to suit your application.
To modify the appearance of a Split Key:

A Split Key allows you to assign a different alpha source for a Key than the fill/alpha associations that are set up during configuration or to use a separate alpha source for a Self Key.

Wipes can be modified to give more distinct qualities and personalize your transitions. The following effects can be adjusted:
To modify time and direction:

The switcher has three timed Aux buses which have access to the following sources:
KM-H3000: The Aux buses can be accessed from control panel buttons.
KM-H2500: The Aux buses can be accessed through the menu system.
To change other wipe modifiers:

To access Aux buses on the KM-H2500:
These special sources are found on the first four buttons on the Preset bus.

To select a special source for an Aux bus:

The switcher has tally relays assigned to inputs as follows (pin 1 is the top right pin when looking at the Tally Port):
To access Aux buses on the KM-H3000:

5 4 3 2 1
9 8 7 6
Figure 11 Tally Port

Once an Aux bus has been selected, you can change the source.
To select a source for an Aux bus:
When the corresponding input is on-air, the associated tally pin is closed, creating a contact closure.
Selecting a Special Source for the Aux Buses
You can select the following special sources by selecting them on the Preset bus:

The switcher has 24 GPI inputs that are used to trigger memory recalls, transitions, and Aux bus input changes.
The GPI inputs are assigned as follows (Pin 1 is the top right pin when looking at the GPI Port).
The switcher has an Editor port that allows you to control your switcher from a device that supports the GVG100 editor protocol. The pinout is as follows:
13 12 11 10 9 8 7 6 5 4 3 2 1
14 15 16 17 18 19 20 21 22 23 24 25
Figure 12 GPI Port
5 4 3 2 1
9 8 7 6
Figure 13 Editor Port
1 Dissolve Key 1
2 Dissolve Key 2
3 Dissolve Key 3 (KM-H 3000 only)
4 Perform Auto Transition
5 Perform Program / Preset Bus cut
6 Perform Key 1 cut
7 Perform Key 2 cut
8 Perform Key 3 cut (KM-H 3000 only)
10 Set Aux Bus 1 to Input 1
11 Set Aux Bus 1 to Input 2
12 Set Aux Bus 1 to Input 3
13 Set Aux Bus 1 to Input 4
The following editors have been tested::
14 Set Aux Bus 1 to Input 5
15 Recall Memory 0a
16 Recall Memory 1a
17 Recall Memory 2a
18 Recall Memory 3a
19 Recall Memory 4a
20 Recall Memory 5a
21 Recall Memory 6a
22 Recall Memory 7a
23 Recall Memory 8a
24 Recall Memory 9a
a. Only memory registers from memory bank 0 can be recalled with a GPI trigger.




This chapter describes the Media-Store operation. Your switcher has 2 Media-Store channels which allow you to display 2 images or animations (composed of a sequence of images) on-air simultaneously.
You can browse the file system on the switcher or a USB drive to select images and animations to load. You must use this method the first time an image or animation is loaded in order for it to be assigned a unique Media number.
Images and animations are assigned unique Media numbers that allow the switcher to identify them. You can load images and animations into Media-Store channels in one of two ways:
To load an image or animation by browsing the file system:

Images must be 24-bit or 32-bit (24-bit image plus 8-bit embedded alpha channel) Targa files.
Animations must be Targa sequences, a collection of individual image files (one file per animation frame).
The individual files share a common name with a sequential frame number appended at the end as follows:
Program bus or on-air Key bus, you will affect on-air images.
These files are treated as a 100 frame animation named Anim.
Turning the knob cycles through all the files and directory names at the current level in the file system.
The switcher supports images and animations with embedded transparency. You must set the second Media-Store channel as the alpha channel of the first Media-Store channel to have the switcher automatically load image data and transparency data into the appropriate Media-Store channels.
Animation Naming Convention

knob to load it into the selected Media-Store channel.
Program bus or on-air Key bus, you may affect on-air images.
Each image and animation is uniquely identified by a Media number. Media numbers are 4 digits and take the following form:
Figure 14 Media Number
Once an image has been assigned a Media number, it can be quickly reloaded by typing the corresponding Media number using the Wipe Pattern buttons. The procedure is slight different if you have locked the Place and Bank values.
To load an image or animation by Media number with a locked place and bank number:

Media numbers are entered using the Wipe Pattern buttons. You can choose to lock the Place and Bank to specific values which allows you to quickly access a subset of images.
To lock or unlock place and bank values:

Program bus or on-air Key bus, you will affect on-air images.

Program bus or on-air Key bus, you will affect on-air images.
To load an image or animation by Media number without a locked place or bank number:

To change an image between shaped and unshaped:
Program bus or on-air Key bus, you will affect on-air images.

Program bus or on-air Key bus, you will affect on-air images.
You can alter the appearance of a Media-Store image by modifying display parameters. The parameters you can modify are:
To modify the position of a Media-Store image:


To change the Media number for an image:

You can set an animation to playback automatically as well as control playback speed and direction.
To modify animation playback:

Program bus or on-air Key bus, you will affect on-air images.
Program bus or on-air Key bus, you will affect on-air images.
You can play an animation manually or automatically and also control the behavior of animation playback.
To manually play an animation:

Program bus or on-air Key bus, you will affect on-air images.
You can save attributes for an image so they are automatically recalled the next time that image is loaded from a USB drive or internal memory.
Image attributes that have been changed since they were last saved are marked with a ‘*’.

To save attributes for an image:

To revert to saved attribute values:

Program bus or on-air Key bus, you will affect on-air images.



Dimensions
Weight:
Inputs
Power Requirements
Analog Output Specifications
USB Port
Tri-level Pulse

The following error messages may appear when starting your switcher.
Table 5 Switcher Error Messages
Error Message Description Solution
DDR 0 Not Found DDR 1 Not Found DDR 0 & 1 Not Found
There is a problem with the switcher DDR memory. The switcher may be used but many features will be limited or disabled
Re-start your switcher. If the problem persists, contact JVC Technical Support for assistance.
Your switcher requires a Panel Module Controller (PMC) upgrade as part of a software upgrade. The switcher may be used without the PMC upgrade but may respond in an unpredictable manner
Allow the PMC upgrade to proceed. Contact JVC Technical Support for assistance if you are unsure about upgrading your switcher.
The following tables list the Supported GVG100 commands and controls.
Table 6 GVG100 Supported Commands
Name MLE/Keyer Length Byte Code Data/Notes
Read MLE Program Bus MLE 2 41 —
Read MLE Preset Bus MLE 2 42 —
Read Keyer Bus Keyer 2 43/44 —
Write MLE Program Bus MLE 3 C1 An invalid xpt request returns a protocol error
Write MLE Preset Bus MLE 3 C2 An invalid xpt request returns a protocol error
Write Keyer Bus Keyer 3 C3/C4 An invalid xpt request returns a protocol error
Read Analog MLE/Keyer 3 45
Write Analog MLE/Keyer 5 C5
Read Light On/off MLE/Keyer 3 46/47 —
Write Light On/off MLE/Keyer 3 C6/C7
Read Wipe Pattern MLE 2 48 —
MLE 3 C8 Valid wipes are 0-9, as per the Wipe Pattern button numbers. An invalid wipe number returns a protocol error.
Read Transition Mode MLE 2 4A —
Bi-level Pulse · Upgrade PMC? · Write Wipe Pattern

Table 6 GVG100 Supported Commands
Name MLE/Keyer Length Byte Code Data/Notes
MLE 3 CA Last 5 bits used; bit 0 is key 1, 1 is key 2, 3 is bkgd, 4 is key 3, 5 is key 4
Read Mle Autotrans Rate MLE 2 4C —
Read Keyer Mix Rate Keyer 2 4D —
Read Fade To Black Rate MLE* 2 7D — *Currently MLE-specific
Write Mle Autotrans Rate MLE 5 CC **
Write Keyer Mix Rate Keyer 5 CD **
—* 5 FD ** *Currently not supported. Fade to black rate is the same as the transition rate.
Write Fade To Black Rate
Read Key Settings Keyer 2 53 Not yet implemented
Write Key Settings Keyer 62(?) D3 Not yet implemented
Learn Into Mem — 3 DA Supports memories 0-9
Recall From Mem — 3 DB Supports memories 0-9
Read Software Version — 2 6C —
Read Field Mode — 2 6D — Field Mark only
Write Field Mode — 2 ED 0 or 1 Field Mark only
All Stop — 3 F2 D0* *Data byte is unused
Read Lamp Status — 3 78 0
Write Lamp Status — 3 F8 — Included for GVG100 spec completeness only.
Write Button Press Both 3 FB
Send Mem To Editor — 3 7E Not yet implemented
Load Mem From Editor — 73 FE Not yet implemented
Data byte 1:
Data byte 2:
Bit 6-7: Ignored Bit 4-5: 4=select key 3, 5=select key 4 Bit 0-3: binary coded decimal (valid range is b0-b1001, or 0-9)
Data byte 3:
Write Transition Mode · **

Table 7 GVG100 Supported Analog Controls
Name MLE/Keyer Byte Code Notes
Key Clip Keyer 0x0A
Key Gain Keyer 0x0B
Vert. Position MLE 0x11
Horz. Position MLE 0x12
Key Matte Fill Hue MLE 0x14 Key mattes not supported
Pattern Size MLE 0x15
Chroma Key Hue Keyer 0x17 Write not supported
Key Matte Border Hue Keyer 0x18 Key mattes not supported
Key Matte Border Sat Keyer 0x19 Key mattes not supported
Key Matte Border Lum Keyer 0x1A Key mattes not supported
Key Matte Fill Lum Keyer 0x1B Key mattes not supported
Aspect MLE 0x1C Aux MLEs not supported
Border Softness MLE 0x1D Aux MLEs not supported
Border Width MLE 0x1E Aux MLEs not supported
Key Matte Fill Sat Keyer 0x1F Key Mattes not supported
Rotate X — 0x20 Not supported
Rotate Y — 0x21 Not supported
Rotate Z — 0x22 Not supported
3D Position X — 0x23 Not supported
3D Position Y — 0x24 Not supported
3D Position Z — 0x25 Not supported
3D Border Softness — 0x26 Not supported
3D Border Width — 0x27 Not supported
Key Clip Keyer 0x08 DSKs
Key Gain Keyer 0x09 DSKs
Table 8 GVG100 Supported Lamps
Name MLE/Keyer Byte Code Notes
Program Bus 0-9 MLE 0x00-0x09 Turning OFF results in a protocol error.
Program Bus On Air MLE 0x0A Turning OFF results in a protocol error.
Key Dissolve Keyer 0x0C
Key Cut Keyer 0x0D
Wipe Trans MLE 0x0E
Dissolve Trans MLE 0x0F
Preset Bus 0-9 MLE 0x10-0x19 Turning OFF results in a protocol error.
Preset Bus On Air MLE 0x1A Turning OFF results in a protocol error.
Aspect On MLE 0x1B Always on. Turning OFF results in a protocol error.
Autotrans MLE 0x0B

Table 8 GVG100 Supported Lamps
Name MLE/Keyer Byte Code Notes
Positioner On MLE 0x1C Always on. Turning OFF results in a protocol error.
Reverse Wipe MLE 0x1D
Dsk Preview Keyer 0x1E Always true. All Keyers show on Preview Turning OFF results in a protocol error.
Fade To Black — 0x1F
Key Bus 0-9 Keyer 0x20-0x29 Turning OFF results in a protocol error.
Key Bus On Air Keyer 0x2A Turning OFF results in a protocol error.
Key Video Fill Keyer 0x2F Always true. Turning OFF results in a protocol error.
Wipe Type MLE 0x30-0x39 Turning OFF results in a protocol error.
Key Invert Keyer 0x40 DSKs. Turning OFF results in a protocol error.
Key Mask Keyer 0x41 DSKs. Turning OFF results in a protocol error.
Key Autokey Keyer 0x42 DSKs. Turning OFF results in a protocol error.
Key Selfkey Keyer 0x43 DSKs. Turning OFF results in a protocol error.
Key Invert Keyer 0x44 Turning OFF results in a protocol error.
Key Mask Keyer 0x45 Turning OFF results in a protocol error.
Memory Mode Toggle — 0x47 Toggles between memory and pattern modes.
Next Trans Is Bkgd — 0x48 Turning OFF results in a protocol error.
Next Trans Is Key 1 — 0x49 Turning OFF results in a protocol error.
Cut MLE 0x4A Turning OFF results in a protocol error.
Key Selfkey Keyer 0x4C Turning OFF results in a protocol error.
Key Autokey Keyer 0x4D Turning OFF results in a protocol error.
Key Chromakey Keyer 0x4E Turning OFF results in a protocol error.
Editor Enable — 0x4F Editor control is always enabled. Turning OFF results in a protocol error.
Keyer Active Keyer 0x52
Table 9 GVG100 Supported Buttons
Name MLE/Keyer Byte code Notes
Program Bus 0-9 MLE 0x00-0x09
Key Trans Keyer 0x0C DSKs
Key Cut Keyer 0x0D DSKs
Wipe Trans MLE 0x0E
Dissolve Trans MLE 0x0F
Preset Bus 0-9 MLE 0x10-0x19
Autotrans MLE 0x0B

Table 9 GVG100 Supported Buttons
Name MLE/Keyer Byte code Notes
Aspect MLE 0x1B Always on. Button press has no effect.
Positioner On — 0x1C Always on. Button press has no effect.
Reverse Wipe MLE 0x1D Doubles as memory store/recall toggle when in memory mode
Dsk Preview — 0x1E Always true. All Keyers show on preview.
Fade To Black 0x1F
Key Bus 0-9 Keyer 0x20-0x29
Key Video Fill Keyer 0x2F Always true.
Wipe Type MLE 0x30-0x39
Key Invert Keyer 0x40 DSKs
Key Mask Keyer 0x41 DSKs
Key Autokey Keyer 0x42 DSKs
Key Selfkey Keyer 0x43 DSKs
Key Invert Keyer 0x44
Key Mask Keyer 0x45
Memory Mode Toggle — 0x47 Toggles between memory mode and pattern mode.
Next Trans Is Bkgd — 0x48
Next Trans Is Key 1 — 0x49
Key Selfkey Keyer 0x4C
Key Autokey Keyer 0x4D
Key Chromakey Keyer 0x4E
Editor Enable — 0x4F Editor control is always enabled.
Cut MLE 0x4A



多格式数字高清切换台
MULTI FORMAT DIGITAL PRODUCTION SWITCHER

Victor Company of Japan, Limited
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.