EN
AMX logo
Official user manual

AMX AXB-232++

20 pages·307 KB·Network Card·PDF·ENDEFRITNLJA
AMX AXB-232++
Table of Contents 32 sections AXB-232++ RS-232/422/485 Interface · Product Information · Front Panel · Rear Panel · … ShowHide
Page 1 of the AMX AXB-232++ user manual — instruction manual
Page 1 · click to enlarge
Page 1

instruction manual

AXlink Bus Controllers

Page 2 of the AMX AXB-232++ user manual — AXB-232++ RS-232/422/485 Interface
Page 2 · click to enlarge
Page 2
Page 2 of the AMX AXB-232++ user manual — AXB-232++ RS-232/422/485 Interface
Page 4 of the AMX AXB-232++ user manual — AXB-232++ RS-232/422/485 Interface
Page 4 · click to enlarge
Page 4

ii AXB-232++ RS-232/422/485 Interface

Table of Contents

Page 5 of the AMX AXB-232++ user manual — Rear Panel
Page 5 · click to enlarge
Page 5

Product Information

The AXB-232++ RS-232/422/485 Interface is an AXlink bus controller that provides remote control for devices that require a variety of control protocols. The AXB-232++ extends RS-232, RS-422, or RS-485 control to remote sources over the 4-wire AXlink data/power bus.

Onboard processing and memory allows the controller to take on complex tasks by itself, reducing the processing burden for the Axcess control system. For example, the control system can use simplified commands for generic video switcher or code control, a modular driver program in the AXB-232++ can process control for specific makes and models.

Front Panel

FIG. 1 displays the front panel of the AXB-232++.

AMX AXB-232++ — Front Panel diagram (page 5)
Fig. 1 · Front Panel

FIG. 1 AXB-232++ front panel

Rear Panel

FIG. 2 displays the rear panel of the AXB-232++.

AMX AXB-232++ — Rear Panel diagram (page 5)
Fig. 2 · Rear Panel

FIG. 2 AXB-232++ rear panel

Product Information

Page 6 of the AMX AXB-232++ user manual — Specifications
Page 6 · click to enlarge
Page 6

Specifications

The following table lists the specifications for the AXB-232++.

Specifications Power12 VDC @ 160 mA ProcessorOn board 32-bit processor and 384K (of non-volatile memory) run Axcess programs independent of the control system. This relieves the AXlink bus and controller for the processing time for controlling those devices. (Requires Axcess Version 3.0 or higher.) Asynchronous data standards• Baud rates - 300, 600, 1200. 2400, 4800, 9600, 19200 and 38400. 56400 is supported via the BAUDMED Send Command (see the Send Commands section on page 9 for details). _ 115200 is supported via the BAUDHIGH Send Command (see the Send Commands section on page 9 for details). _ • Data bits - 7, 8, and 9 • Stop bits - 1 and 2 • Parity - None, Odd, Even, Mark and Space Buffers• 1KB input buffer • 1KB AXlink buffer Front Panel AXlink LEDsGreen AXlink status indicator: • Full-Off indicates no power is being received or the controller is not functioning properly. • One blink per second power is active and AXlink communication is functioning. • Full-On indicates power is active and AXlink data communication is not functional. RX LED (Red)Blinks to indicate the AXB-232++ is receiving RS-232, RS-422, or RS-485 data. The RX LED blinks even if the data being received is incorrect. TX LED (Red)Blinks to indicate the AXB-232++ is sending RS-232, RS-422, or RS-485 data. DEVICE DIP SwitchAn eight-position DIP switch used to set the device number for the AXB-232++. Refer to Setting the DEVICE DIP switch, on page 4, and Setting jumper JP5 to set the RS-422 port for RS-485 use section on page 4 for more information. RS232/422 DIP SwitchAn eight-position DIP switch used to set the communication parameters for the RS-232/422 device. Refer to Setting the RS-232/422 DIP switch, on page 5, for more information. Rear Panel Hardware handshaking connectorAn RTS/CTS data connector that can be wired for hardware handshaking if called for by the controlled device (4-pin male). RS422/232 connectorA captive-wire connector wired for RS-422/232 data control (8-pin male). AXlink connectorReceives power and data via the AXlink bus and AXlink system controller (4-pin male). Internal JumpersSets differential input termination and enables RS-485 output. SupportsXON/XOFF software and hardware handshaking Dimensions (HWD)1.5" x 5.5" x 5.5" (3.81 cm x 13.97 cm x 13.97 cm) Weight1.1 lbs. (498.95 g) EnclosureMetal with black matte finish Included Accessories• AXlink connector (4-pin female) • Phoenix connector (8-pin male) Optional Accessories• CC-232 Control Cable • AC-RK Accessory Rack Kit • 12 VDC power supply, 800 mA

Product Information

Page 7 of the AMX AXB-232++ user manual — Setting jumper JP4 to terminate RS-422 input with 100 ohms
Page 7 · click to enlarge
Page 7

The AXB-232++ can be used as an independent RS-232/422/485-controlled interface by setting the internal jumpers. Configure the communication parameters using the DIP switches on the front panel.

Setting the Internal Jumpers

JP4

JP5

CORP.

AXB-232++

FIG. 3 Location of internal jumpers

Setting jumper JP4 to terminate RS-422 input with 100 ohms

Terminating a device involves installing a 100 ohm line terminator, this is typically used to achieve better communication and signal integrity. You will want to terminate when the communication is at a high data rate or over a long distance. Termination can be harmful because it increases the current in the line, and more radiation that could interfere with signals.

Jumper JP4 places 100 Ohms termination across RS422 receive data pins 5 & 6:

1. Disconnect the RS-232/422/485 connectors.
2. Unscrew the two screws on the rear panel, and remove the panel.
3. Slide the circuit board out of the enclosure.
4. Locate the JP4 jumper (FIG. 3).
5. Install the jumper in the 'ON' position (default setting = OFF).
6. Slide the circuit board back into the enclosure.
7. Replace the panel, and refasten the screws.
8. Reconnect the RS-232/422/485 connectors.

Internal jumper JP4 · Internal jumper JP5 · front

Page 8 of the AMX AXB-232++ user manual — Setting the DEVICE DIP switch
Page 8 · click to enlarge
Page 8

Setting jumper JP5 to set the RS-422 port for RS-485 use

1. Disconnect the RS-232/422/485 connectors.
2. Unscrew the two screws on the rear panel, and remove the panel.
3. Slide the circuit board out of the enclosure.
4. Locate the JP5 jumper (see FIG. 3 on page 3).
5. Set jumper JP5 to the ON position (the default setting is OFF).
6. Slide the circuit board back into the enclosure.
7. Replace the panel, and refasten the screws.
8. Reconnect the RS-232/422/485 connectors.

Setting the DIP Switches

Use the DIPSwitch 2.0 application available for free download from AMX to quickly figure out DIP Switch settings for all types of DIP Switches.

Setting the DEVICE DIP switch

Set the device number on DEVICE DIP switch, located on the front of the AXB-232++. The device can be 1 of the 255 devices in an Axcess control system. The device number must match the device assignment in the Axcess program. Device numbers are assigned into the following three segments:

z Cards 1 through 95

z Boxes 96 through 127

z Panels 128 through 255

Set the device number by setting the device DIP switches. The device number is the total of all of the switches in the ON position, and take effect by cycling the power. The following table shows the switch numbers and their corresponding values.

DEVICE DIP Switch Settings Position12345678 Value1248163264128
Page 9 of the AMX AXB-232++ user manual — Setting the RS-232/422 DIP switch
Page 9 · click to enlarge
Page 9

Setting the RS-232/422 DIP switch

Set the stop bits, data bits, parity, and baud rate on the RS-232/422 DIP switch, located on the front panel (see FIG. 1 on page 1). The AXB-232++ supports the following asynchronous data standards:

z Stop bits 1 and 2

z Data bits 7, 8, and 9

z Parity None, Odd, Even, Mark, and Space

z Baud rates 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200 and 38,400.

z 57,600 is achieved by setting the DIP switch to 300 baud, and using the

’BAUDMED’ Send_Command (see the Send_Commands section on page 9 for details).

z 115,200 is achieved by setting the DIP switch to 300 baud, and using the

’BAUDHIGH’ Send_Command (see the Send_Commands section on page 9 for details).

The table below shows the RS-232/422 DIP switch numbers, functions, and their corresponding values.

RS-232/422 DIP Switch Settings Switch Function1 Stop Bits2 Data Bits3 4 5 Parity6 7 8 Baud Rates Setting ValueOff 2 bitsOff 7 bitsOff Off Off UnusedOff Off Off 300 On On 1 bit 8 bits RS232/422 1 2 3 4 5 6 7 8 ONOn 1 bitOn 8 bitsOn Off Off UnusedOn Off Off 600 Off On Off UnusedOff On Off 1,200 On On Off UnusedOn On Off 2,400 Off Off On MarkOff Off On 4,800 On Off On EvenOn Off On 9,600 Off On On OddOff On On 19,200 On On On NoneOn On On 38,400
AMX AXB-232++ — Setting the RS-232/422 DIP switch diagram (page 9)
Fig. 3 · Setting the RS-232/422 DIP switch
Page 10 of the AMX AXB-232++ user manual — PWR AXP AXM GND
Page 10 · click to enlarge
Page 10

Wiring Devices to the AXB-232++

Preparing captive wires

To connect the wiring into a captive-wire connector:

1. Strip 1/4 inch off the wire insulation for all four wires.
2. Tin 2/3 of the exposed wire.
3. Insert each wire into the appropriate captive-wire connector up to the insulation.
4. Tighten the captive screws to secure the fit in the connector.

If the device is using a separate power supply, do not connect the power wiring from the AXB-232++ to that device.

Wiring guidelines

The interface requires a 12 VDC power to operate properly. The interface uses a PSN2.8 power supply. The Central Controller supplies power via the AXlink cable or external 12 VDC power supply. The maximum wiring distance between the Central Controller and interface is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The table below lists wire sizes and maximum lengths allowable between the AXB-RS232++ and Central Controller. The maximum wiring lengths for using AXlink power are based on a minimum of 13.5 volts available at the Central Controller’s power supply.

Wiring Guidelines at 160 mA Wire SizeMaximum Wiring Length 18 AWG733.57 feet (223.59 m) 20 AWG464.11 feet (141.46 m) 22 AWG289.35 feet (88.19 m) 24 AWG182.39 feet (55.59 m)

Using AXlink

Connect the AXlink wiring to the connector on the AXB-232++ as shown in FIG. 4.

PWR AXP AXM GND

PWR AXP AXM GND

FIG. 4 AXlink bus and +12 VDC power wiring

Using AXlink and External Power Supply

Connect the AXlink and power wiring to the connector on the AXB-232++ as shown in FIG. 5.

PWR AXP AXM GND

PWR AXP AXM GND

+12 VDC GND

FIG. 5 AXlink bus and +12 VDC power wiring

AXlink System · AXlink System · Power Supply

Page 11 of the AMX AXB-232++ user manual — AXB232++ TX +
Page 11 · click to enlarge
Page 11

Using RS-232

When communicating via RS-232, connect the wiring as shown in FIG. 6.

TX RX GND

RX

TX

+12V

TX - RX + RX -

TX +

FIG. 6 RS-232 wiring

Using Hardware Handshaking

When the controlled device requires hardware handshaking, connect the wiring as shown in FIG. 7.

RTS CTS RTS CTS 1 2 3 4

FIG. 7 Hardware handshaking wiring

Using RS-422

When communicating via RS-422, connect the wiring as shown in FIG. 8.

RX GND

TX

+12V GND

RXTX+ TX-

TX - RX + RX -

TX +

RX+

FIG. 8 RS-422 wiring

Using RS-485

When communicating via RS-485, connect the wiring as shown in FIG. 9.

RX GND

TX

+12V

Device TX - RX + RX -

AXB232++ TX +

FIG. 9 RS-485 wiring

GND AXB- 232++ Device · AXB-232++ Device · AXB- 232++ Device

Page 12 of the AMX AXB-232++ user manual — Replacing the Lithium Batteries
Page 12 · click to enlarge
Page 12

Rack-mounting the AXB-232++ (optional)

To rack-mount the AXB-232++ into the optional AC-RK Accessory Rack Kit:

1. Remove any connected power, and AXlink and RS-232 connectors from the rear panel.
2. Remove the two screws on the front panel of the AXB-232++.
3. Remove the front panel and space bracket behind the panel.
4. Place the unit in the appropriate opening in the AC-RK.
5. Place the front panel of the AXB-232++ on the front of the rack, over the unit.
6. Fasten the front panel to the rack and unit with the two screws you removed.

Replacing the Lithium Batteries

The AXB-232++’s lithium batteries have a life of approximately 5 years to protect its memory. When DC power is on, the batteries are not used. When you install the AXB-232++, record the date the batteries should be replaced.

There is a danger of explosion if you replace the batteries incorrectly. Replace batteries with the same or equivalent type recommended by the manufacturer. Dispose of the used batteries according to the manufacturer’s instructions. Never recharge, disassemble, or heat batteries above 212°F (100°C). Never solder directly to the batteries or expose the contents of the batteries to water.

Before removing the lithium batteries, contact your dealer and verify that they have a current copy of your program to avoid an inadvertent loss of data and prevent an unnecessary service outage.

1. Discharge the static electricity from your body.
2. Unplug the two-pin power connector and any other connectors.
3. Remove the two screws on the front panel.
4. Remove the front panel, and slide the circuit board out of the enclosure.
5. Carefully slide each battery out of its socket (FIG. 10), and insert the new battery.

Battery (CR2032 type - 20mm coin cell)

FIG. 10 Lithium battery and socket

6. Slide the circuit board back into the enclosure.
7. Replace the front panel and refasten the two screws.
8. Reconnect any connectors that you removed.

socket

Page 13 of the AMX AXB-232++ user manual — SEND_COMMAND AXB232,'CB1OFF'
Page 13 · click to enlarge
Page 13

Send_Commands

The AXB-232++ supports the same command set as the AXC-232. The following table lists the AXB-232++ Send_Commands.

AXB-232++ Send_Commands

B9MOFF

Syntax:

'B9MOFF'

Sets data bit mode to normal with DIP switch settings (default).

Example:

SEND_COMMAND AXB232,'B9MOFF'

Sets the data bit mode to normal.

B9MON

Syntax:

Enables a special mode to override DIP switch settings.

'B9MON'

The mode, nine data bits with one stop bit, overrides the data, stop, and parity settings. When the AXB-232++ issues this command, it locks in the baud rate determined by the current DIP switch setting.

Example:

SEND_COMMAND AXB232,'B9MON'

Overrides the DIP switch settings.

BAUDHIGH

Syntax:

Enables 115,200 baud rate when the DIP switch is set to 300 baud.

'BAUDHIGH'

Example:

SEND_COMMAND AXB232,'BAUDHIGH'

Enables 115,200 baud rate.

BAUDLOW

Syntax:

Enables 300 baud rate when the DIP switch is set to 300 baud setting (default).

'BAUDLOW'

Example:

SEND_COMMAND AXB232,'BAUDLOW'

Enables 300 baud rate.

BAUDMED

Syntax:

Enables 57,600 baud rate when the DIP switch is set to 300 baud.

'BAUDMED'

Example:

SEND_COMMAND AXB232,'BAUDMED'

Enables 57,600 baud rate.

CB1ON

Syntax:

Enables placement of charac- ters in the buffer specified by CREATE_BUFFER 1 (default).

'CB1ON'

Example:

SEND_COMMAND AXB232,'CB1ON'

Enables placement of characters in the buffer.

CB1OFF

Syntax:

Disables placement of char- acters in the buffer specified by CREATE_BUFFER 1.

'CB1OFF'

Example:

SEND_COMMAND AXB232,'CB1OFF'

Disables placement of characters in the buffer.

Page 14 of the AMX AXB-232++ user manual — SEND_COMMAND AXB232,'RXCLR'
Page 14 · click to enlarge
Page 14

AXB-232++ Send_Commands (Cont.)

CHARD

Syntax:

Sets delay between all transmitted characters to the increment specified.

Variable:

time = 100 microsecond increments 0 - 255.

Example:

SEND_COMMAND AXB232,'CHARD-10'

Sets 1mS delay between all transmitted characters.

CTSPSH

Syntax:

Enables PUSHes and RELEASEs.

'CTSPSH'

Example:

SEND_COMMAND AXB232,'CTSPSH'

Enables PUSHes, RELEASEs, and status on channel 255 ([0,255] within the AXB-232++) for CTS hardware handshake input. If CTS is high, the channel is on.

CTSPSHF

Syntax:

'CTSPSHF'

Disables the 'CTSPSH' command.

Example:

SEND_COMMAND AXB232,'CTSPSHF'

Disables the 'CTSPSH' command.

EOFF

Syntax:

Disables the 'EON ' command (default).

'EOFF'

Example:

SEND_COMMAND AXB232,'EOFF'

Disables the 'EON' command.

EON

Syntax:

Forces the AXB-232++ to ignore the transmitted char- acters on its receiver.

'EON'

Example:

SEND_COMMAND AXB232,'EON'

Forces the AXB-232++ to ignore the transmitted characters on its receiver. When using RS-485, the transmitter and receiver are tied together.

HSOFF

Syntax:

Disables hardware handshaking (default).

'HSOFF'

Example:

SEND_COMMAND AXB232,'HSOFF'

Enables placement of characters in the buffer.

HSON

Syntax:

'HSON'

Disables placement of char- acters in the buffer specified by CREATE_BUFFER 1.

Example:

SEND_COMMAND AXB232,'HSON'

Enables hardware handshaking.

RXCLR

Syntax:

Clears any characters in the Receive buffer waiting to be sent to the Master.

'RXCLR'

Example:

SEND_COMMAND AXB232,'RXCLR'

Clears any characters in the Receive buffer waiting to be sent to the master. If 'RXCLR' is sent while RTS is low, RTS returns high.

'CHARD-'

Page 15 of the AMX AXB-232++ user manual — Axcess program characteristics
Page 15 · click to enlarge
Page 15

AXB-232++ Send_Commands (Cont.)

RXOFF

Syntax:

AXB-232++ does not pass on received characters to the Master (default).

'RXOFF'

Example:

SEND_COMMAND AXB232,'RXOFF'

AXB-232++ does not pass on received characters to the master.

RXON

Syntax:

'RXON'

Enables AXB-232++ to send incoming characters received to the Master.

Example:

SEND_COMMAND AXB232,'RXON'

Enables AXB-232++ to send incoming characters received to the master.

The AXB-EM automatically sends this command to the AXB-232++ when it executes a 'CREATE_BUFFER' program instruction.

TXCLR

Syntax:

Clears and stops any charac- ters waiting in the Transmit buffer.

'TXCLR'

Example:

SEND_COMMAND AXB232,'TXCLR'

Clears and stops any characters waiting in the Transmit buffer.

XOFF

Syntax:

Disables software handshaking (default).

'XOFF'

Example:

SEND_COMMAND AXB232,'XOFF'

Disables software handshaking.

XON

Syntax:

Enables software handshaking.

'XON'

Example:

SEND_COMMAND AXB232,'XON'

Enables software handshaking.

ZAP!

Syntax:

Clears the Axcess program in the AXB-232++.

'ZAP!'

Example:

SEND_COMMAND AXB232,'ZAP!'

Clears the Axcess program in the AXB-232++.

Axcess program characteristics

The AXB-232++ is capable of running Axcess programs. It handles string processing, relieving AXlink and the Master of the processing times.

Page 16 of the AMX AXB-232++ user manual — SEND_COMMAND AXB232,"27,20,1"
Page 16 · click to enlarge
Page 16

Send_String Escape Sequences

The AXB-232++ does not regard certain three-character combinations within a Send_String program as literal characters, but as commands. The following table lists those combinations.

Send_String Escape Sequences

Syntax:

Sends a break character of the specified length of time.

Variable:

time = 100 microsecond increments 1 - 255.

Example:

SEND_STRING AXB232,"27,17,10"

Sends a break character of 1mS.

Syntax:

Sets the ninth data bit to 1 for all of the following characters to be transmitted.

Example:

SEND_STRING AXB232,"27,18,1"

Sets the ninth data bit to 1 for all of the following characters to be transmitted. Used in conjunction with the 'B9MON' command.

Syntax:

Clears the ninth data bit to 0 for all of the next characters to be transmitted.

Example:

SEND_STRING AXB232,"27,18,0"

Clears the ninth data bit to 0 for all of the next characters to be transmitted. Used in conjunction with the 'B9MON' command.

Syntax:

Inserts a delay before the next character to be transmitted.

Variable:

time = 100 microsecond increments 1 - 255.

Example:

SEND_COMMAND AXB232,"27,19,10"

Inserts a 1mS delay before the next character to be transmitted.

Syntax:

Asserts RTS hardware hand- shake output high.

Example:

SEND_COMMAND AXB232,"27,20,0"

Asserts RTS hardware handshake output high.

Syntax:

Asserts RTS hardware hand- shake output low.

Example:

SEND_COMMAND AXB232,"27,20,1"

Asserts RTS hardware handshake output low.

Show 12 more labels / short text on this page
27,17,<time> · "27,17,<time>" · 27,18,1 · "27,18,1" · 27,18,0 · "27,18,0" · 27,19,<time> · "27,19,<time>" · 27,20,0 · "27,20,0" · 27,20,1 · "27,20,1"
Page 17 of the AMX AXB-232++ user manual — SEND_COMMAND AXB_232, 'CB1OFF'
Page 17 · click to enlarge
Page 17

AXB-232++ Program Statements

The Axcess program of the AXB-232++ communicates with the master as Device 0. Its device communicates with the RS232/422 Input/Output (I/O) of the AXB-232++ as Device 1. The following table lists AXB-232++ statements.

AXB-232++ Program Statements

CREATE_BUFFER 0,buffer Places strings that come from the Master into buffer. If no CREATE_BUFFER 0 exists, the incoming strings from the Master are sent out the RS232 port.

CREATE_BUFFER 1,buffer Places strings that come from the RS-232 port into buffer. If no CREATE_BUFFER 1, exists, the incoming strings are sent to the Master.

CREATE_BUFFER 2,buffer Places commands (i.e. SEND_COMMANDs) that come from the AXlink Master into the buffer. Each command will be preceded by 2 characters: The first char- acter will always be an '*', the second character is the length of the command, the remaining n characters (as given in the second character) are the command itself.

Places levels sent by the master for level in variable.

OFF[0,channel] • Sends a RELEASE to the Master.

  • Sends a message that channel is off.

OFF[1,channel] Turns off a channel. This command has no external effect. It can be used as status.

ON[0,channel] • Sends a PUSH to the Master.

  • Sends a message that channel is on.

ON[1,channel] Turns on channel. This command has no external effect. It can be used as sta- tus.

SEND_COMMAND 0,command Sends command to the Master. Provides support for commands like 'RDS'.

SEND_COMMAND 1,command Sends command to the AXB-232++ as if the Master had sent it.

SEND_COMMAND AXB_232, 'BAUDHIGH'

Sets the baud rate to 115.2k (DIP switch set to 300).

SEND_COMMAND AXB_232, 'BAUDLOW'

Sets the baud rate to 300 (DIP switch set to 300).

SEND_COMMAND AXB_232, 'CB1ON'

Enables placement of characters in the buffer specified by CREATE_BUFFER 1.

SEND_COMMAND AXB_232, 'CB1OFF'

Disables placement of characters in the buffer specified by CREATE_BUFFER 1.

SEND_LEVEL 0,level,variable Sends variable as the value for level.

SEND_STRING 0,string Sends string to the Master.

SEND_STRING 1,string Sends string out the RS-232 port.

Statement Function · CREATE_LEVEL 0,level,variable

Page 18 of the AMX AXB-232++ user manual — SET_PULSE_TIME(12)
Page 18 · click to enlarge
Page 18

Xmodem Timing Commands

The following table lists the AXB-232++ Xmodem timing commands. Xmodem timeouts exist to accommodate potential Ethernet delays and for consistency among and within products. Any Xmodem timing command will change timing and retries for Axcess code download as well as Softrom transfer.

Xmodem Timing Commands

'TIMEOUT XX' Xmodem timeouts via the Program Port. (Default is 10 sec.)

SEND_COMMAND SERIAL, 'XMTO XX'

Over AXlink, where XX is from one to 50 seconds in 1-second increments.

'RETRY XX' Xmodem retries via the Program Port. (Default is 5.)

SEND_COMMAND SERIAL, 'XMRT XX'

Over AXlink where XX is from one to 10 in increments of one.

AXlink Master Statements

The following table lists the AXlink Master statements for the AXB-232++.

AXlink Master Statements

MIN_TO Activates a channel or variable for a minimum amount of time-even if the corre- sponding device-channel is released. The time duration is determined by SET_PULSE_TIME.

Executes PUSH[0,channel] within AXB-232++.

Executes RELEASE[0,channel] within AXB-232++.

PULSE Turns on a channel or variable for a certain amount of time. Once the time elapses, the channel or variable is turned off. The Pulse time remains the same value until it is changed within the program.

Example:

SET_PULSE_TIME(12)

Sets the current duration of future Pulses to 1.2 seconds.

AXB-232++ interprets command.

SEND_LEVEL AXB_232,level, variable

Places the variable into the CREATE_LEVEL variable, if it were defined in the AXB-232++ DEFINE_START section.

Places the string into the CREATE_BUFFER buffer, if you defined the buffer in the AXB-232++ DEFINE_START section. If it were not, this command trans- mits the string out the RS-232 port.

TO Activates a channel or variable for as long as the corresponding device-channel of its Push statement is activated. When the device-channel referenced by the Push statement changes from off to on, the TO starts activat- ing the device-channel or variable in the brackets following it. When the device-channel of its Push is released, the TO statement stops activating its device-channel or variable. For this reason, TO must be found only underneath a Push statement.

Show 6 more labels / short text on this page
Command Description · Statement Function · ON[AXB_232, channel] · OFF[AXB_232, channel] · SEND_COMMAND AXB_232,command · SEND_STRING AXB_232,string
Page 19 of the AMX AXB-232++ user manual — Axcess Master Mode
Page 19 · click to enlarge
Page 19

Reserved Channels

The following table lists the channels reserved on Device 0.

Reserved Channels

Channel 254 This is only valid within the device and is not sent to the AXlink Master. Reflects AXlink status:

  • When AXlink is active, this channel is on.
  • When AXlink is inactive, this channel is off.
  • When this channel changes state, the AXB-232++ generates a PUSH or RELEASE.

Channel 255 Reflects the state of the CTS input. If the AXB-232++ receives a 'CTSPSH' command, it generates PUSHes for both the Master and the AXB-232++.

Axcess Master Mode

When an Axcess device is placed in "Master Mode", the Central Controller’s PROGRAM port is moved to the Axcess device’s RS-232 port.

Press the escape key, then type either MC or MD:

z MC - connects the device in Master Mode

z MD - disconnects the device

where means "press the Esc key".

Master Mode can be very useful in situations where physical access to the Central Controller’s PROGRAM port is not practical (for example, in installations where the Central Controller is located a long distance from the bus device(s)).

Channel Function

Page 20 of the AMX AXB-232++ user manual — Reserved Channels
Page 20 · click to enlarge
Page 20

032-004-1718 9/05 ©2005 AMX Corporation. All rights reserved. AMX, the AMX logo, the building icon, the home icon, and the light bulb icon are all trademarks of AMX Corporation. In Canada doing business as Panja Inc.

Last Revision09/12/05

AMX reserves the right to alter specifications without notice at any time.

  • ARGENTINA
  • AUSTRALIA
  • BELGIUM
  • BRAZIL
  • CANADA
  • CHINA
  • ENGLAND
  • FRANCE
  • GERMANY
  • GREECE
  • HONG KONG
  • INDIA
  • INDONESIA
  • ITALY
  • JAPAN
  • LEBANON
  • MALAYSIA
  • MEXICO
  • NETHERLANDS
  • NEW ZEALAND
  • PHILIPPINES
  • PORTUGAL
  • RUSSIA
  • SINGAPORE
  • SPAIN
  • SWITZERLAND
  • THAILAND
  • TURKEY
  • USA
  • ATLANTA
  • BOSTON
  • CHICAGO
  • CLEVELAND
  • DALLAS
  • DENVER
  • INDIANAPOLIS
  • LOS ANGELES
  • MINNEAPOLIS
  • PHILADELPHIA
  • PHOENIX
  • PORTLAND
  • SPOKANE
  • TAMPA
  • 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 USA
  • 800.222.0193
  • 469.624.8000
  • 469-624-7153 fax
  • 800.932.6993 technical support
  • <a href="http://www.amx.com" rel="nofollow noopener" target="_blank">www.amx.com</a>
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the AMX AXB-232++

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.