TECHNICAL MANUAL INSTALLATION MANUAL FOR DOMESTIC UNITS INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS FOR JACKSON MODELS: HT-1 HT-2 LT-1 LT-3 Jackson MSC, Inc. P.O. BOX 1060 HWY. 25E BARBOURVILLE, KY. 40906 FAX (606) 523-9196 PHONE (606) 523-9795 www.
.
i REVISION REVISION DATE MADE BY APPLICABLE ECN DETAILS D 06-29-04 MAW N/A CONVERTED TO NEW LAYOUT.
ii NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL: LT-3 HT-1 = Detergent dispensing unit for high temp dishmacines. HT-2 = Detergent and rinse aid dispensing unit for high temp dishmachines. LT-1 = Sanitizer dispensing unit for low temp dishmachines.
iii TABLE OF CONTENTS SECTION DESCRIPTION PAGE I. SPECIFICATION INFORMATION Dimensions 2 II. INSTALLATION/OPERATION INSTRUCTIONS Installation & Operation Instructions, HT-1 & HT-2 4 Installati.
1 SECTION 1: SPECIFICATION INFORMATION.
2 SECTION 1: SPECIFICATION INFORMATION DIMENSIONS.
3 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS.
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION/OPERATION INSTRUCTIONS HT-1 & HT-2 DISPENSERS Mount the chemical dispenser unit in a convienent location on the wall. VERY IMPORTANT: Do not use a domestic type detergent in this machine at any time.
5 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION / OPERATION INSTRUCTIONS LT-1 & LT-3 DISPENSERS The dishmachine is a “DUMP AND FILL” type unit that dumps (drains) the wash water after each washing cycle. Water added from the fresh water final rinse is used for the next washing cycle.
6 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION / OPERATION INSTRUCTIONS LT-1 & LT-3 DISPENSERS (CONTINUED) LIQUID DETERGENT DISPENSING POINT (LT-3 O nly) : Liquid detergent will be dispensed into machine from factory supplied hole at back of the tub above the basket strainer.
Installation Instructions: 1. Identify the appropriate location for the box. 2. Make sure the electrical supply to the dishmachine has been turned off at the supply circuit breaker. 3. Loosen the two screws in the upper corners of the box and open. (See photo #1) 4.
8 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS INSTALLATION INSTRUCTIONS & DIAGRAMS for the LT-1 & LT-3 1. Identify the appropriate location for the box. 2. Make sure the electrical supply to the dishmachine has been turned off at the supply circuit breaker.
9 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CHEMICAL DISPENSING EQUIPMENT HT-1 & HT-2 TO PREPARE PUMPS FOR OPERATION The HT-1 is a chemical dispensing unit supplied with a detergent pump. Locate the open end of the chemical tube with the tube stiffener and place in the appropriate container.
10 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CHEMICAL DISPENSING EQUIPMENT LT-1 & LT-3 TO PREPARE PUMPS FOR OPERATION The LT-1 is a chemical dispensing unit supplied with a sanitizer chemical pump. Locate the open end of the chemical tube with the tube stiffener and place in the appropriate container.
11 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CAM TIMER OPERATION FOR HT-1 The cam timer is a 2 minute 6 cam timer with an OFF-DRAIN function. The following is a description of set points for each cam and function for each switch. CAM 1: Cam 1 is a cut cam with a single notch and serves as the Cycle/Reset.
12 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CAM TIMER OPERATION FOR HT-1 (CONTINUED) CAM 6: Cam 6 is an adjustable cam and controls the detergent pump. FUNCTION: The detergent pump cam works off the normally closed contacts of cam 6. This requires the switch to be held open by the cam and allowed to drop into the notch to operate the pump.
13 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CAM TIMER OPERATION FOR HT-2 The cam timer is a 2 minute 6 cam timer with an OFF-DRAIN function. The following is a description of set points for each cam and function for each switch. CAM 1: Cam 1 is a cut cam with a single notch and serves as the Cycle/Reset.
14 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CAM TIMER OPERATION FOR HT-2 (CONTINUED) FUNCTION: The rinse aid pump cam works off the normally closed contacts of cam 5. This requires the switch to be held open by the cam and allowed to drop into the notch to operate the pump.
15 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CAM TIMER OPERATION FOR LT-1 The cam timer is a 2 minute 8 cam timer with an OFF-DRAIN function. The following is a description of set points for each cam and function for each switch. CAM 1: Cam 1 is a cut cam with a single notch and serves as the Cycle/Reset.
16 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CAM TIMER OPERATION FOR LT-1 (CONTINUED) CAM 6: Cam 6 is an adjustable cam and controls the sanitizer pump. FUNCTION: The sanitizer pump cam works off the normally closed contacts of cam 6. This requires the switch to be held open by the cam and allowed to drop into the notch to operate the pump.
17 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CAM TIMER OPERATION FOR LT-3 The cam timer is a 2 minute 6 cam timer with an OFF-DRAIN function. The following is a description of set points for each cam and function for each switch. CAM 1: Cam 1 is a cut cam with a single notch and serves as the Cycle/Reset.
18 SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS CAM TIMER OPERATION FOR LT-3 (CONTINUED) CAM 6: Cam 6 is an adjustable cam and controls the sanitizer pump. FUNCTION: The sanitizer pump cam works off the normally closed contacts of cam 6. This requires the switch to be held open by the cam and allowed to drop into the notch to operate the pump.
19 SECTION 3: PARTS SECTION.
20 SECTION 3: PARTS SECTION HT-1 ASSEMBLY 4 3 1 *7 2 10 13 *5 6 14 12 11 15 16 17 9 10 8 18.
21 SECTION 3: PARTS SECTION HT-1 ASSEMBLY (CONTINUED) ITEM QTY DESCRIPTION Mfg. No. 1 Complete HT-1 Assembly 5700-002-51-98 11 Box, Fiberglass Single Chemical Feeder Pump 5700-031-73-03 21 Decal, Warn.
4 12 15 3 2 1 7 8 9 10 4 *5 16 14 12 13 11 6 15 9 10 11 17 16 22 SECTION 3: PARTS SECTION HT-2 ASSEMBLY.
23 SECTION 3: PARTS SECTION HT-2 ASSEMBLY (CONTINUED) ITEM QTY DESCRIPTION Mfg. No. 1 Complete HT-2 Assembly, 240V 5700-031-75-62 1 Complete HT-2 Assembly, 115V 5700-002-84-70 11 Box, Fiberglass Doubl.
ITEM QTY DESCRIPTION Mfg. No. 1 Inner Panel Assembly, 240V 5700-002-10-21 1 Inner Panel Assembly, 115V 5700-002-84-71 11 Panel 5700-021-74-54 21 Transformer, 20VA 208/240V - 24V 5950-011-61-67 21 Tran.
4 3 1 *7 2 10 13 *5 6 14 12 11 15 16 17 9 10 8 18 25 SECTION 3: PARTS SECTION LT-1 ASSEMBLY.
26 SECTION 3: PARTS SECTION LT-1 ASSEMBLY (CONTINUED) ITEM QTY DESCRIPTION Mfg. No. 1 Complete LT-1 Assembly 5700-031-75-60 11 Box, Fiberglass Single Chemical Feeder Pump 5700-031-73-03 21 Decal, Warn.
3 5 14 15 19 2 1 21 22 16 17 3 *6 18 9 12 11 10 13 19 7 8, 4 8, 4 22 20 20 18 23 23 19 27 SECTION 3: PARTS SECTION LT-3 ASSEMBLY.
28 SECTION 3: PARTS SECTION LT-3 ASSEMBLY (CONTINUED) ITEM QTY DESCRIPTION Mfg. No. 1 Complete LT-3 Assembly, 115V 5700-031-75-61 1 Complete LT-3 Assembly, 240V 5700-002-37-80 11 Box, Fiberglass Tripl.
29 SECTION 3: PARTS SECTION CHEMICAL FEEDER PUMP ASSEMBLY Screw, 6-32 x 3/4” Phillips Pan Head 4 per 5305-011-37-05 Roller, Red (Detergent/Sanitizer) 4320-111-36-70 Roller, White (Rinse Aid) 4320-00.
30 SECTION 4: ELECTRICAL SCHEMATICS.
31 SECTION 4: ELECTRICAL DIAGRAMS HT-1 208-240 VOLT, 60 HERTZ, SINGLE PHASE TO DETERGENT SIGNAL CAM 6 SM RED RED TO COMMON NEUTRAL WIRE POWER LEAD FOR PRIME SW S4 WHITE S4 DETERGENT PRIME SWITCH DETERGENT PUMP MOTOR - 36 RPM SM 09905-002-51-94 REV.
32 SECTION 4: ELECTRICAL DIAGRAMS HT-2 115 VOLT, 60 HERTZ, SINGLE PHASE.
33 SECTION 4: ELECTRICAL DIAGRAMS HT-2 208-240 VOLT, 60 HERTZ, SINGLE PHASE.
34 SECTION 4: ELECTRICAL DIAGRAMS LT-1 115 VOLT, 60 HERTZ, SINGLE PHASE.
35 SECTION 4: ELECTRICAL DIAGRAMS LT-3 115 VOLT, 60 HERTZ, SINGLE PHASE.
36 SECTION 4: ELECTRICAL DIAGRAMS LT-3 240 VOLT, 60 HERTZ, SINGLE PHASE.
37 SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS.
38 SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS ALABAMA TO HAWAII ALABAMA: JONES-McLEOD APPLIANCE SVC 1616 7TH AVE. NORTH BIRMINGHAM, AL 35203 (205) 251-0159 800-821-1150 FAX: (205) 322-1440 service@jones-mcleod.
39 SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS IDAHO TO MISSISSIPPI IDAHO: RON'S SERVICE 703 E 44TH STREET STE 10 GARDEN CITY, ID 83714 (208) 375-4073 FAX: (208) 375-4402 RESTAURANT APPLIANCE SVC. 7219 ROOSEVELT WAY NE SEATTLE, WA 98115 (206) 524-8200 800-433-9390 FAX: (206) 525-2890 info@restappl.
40 SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS MISSISSIPPI TO NORTH CAROLINA MISSISSIPPI (cont.): GCS SERVICE INC. 5755 GALLANT DRIVE. JACKSON, MS 39206 (601) 956-7800 800-274-5954 FAX: (601) 956-1200 GCS SERVICE INC. 3717 CHERRY ROAD MEMPHIS, TN 38118 (901) 366-4587 800-262-9155 FAX: (901) 366-4588 MISSOURI: GCS SERVICE INC.
41 SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS NORTH CAROLINA TO TEXAS NORTH CAROLINA (cont.): AUTHORIZED APPLIANCE SERVICE CENTER 109 HINTON AVE. WILMINGTON, NC 28403 (910) 313-1250 FAX: (910) 313-6130 WHALEY FOODSERVICE 8334-K ARROWRIDGE BLVD CHARLOTTE, NC 28273 (704) 529-6242 FAX: (704) 529-1558 info@whaleyfoodservice.
42 SECTION 5: JACKSON MAINTENANCE & REPAIR CENTERS TEXAS TO WYOMING/CANADA TEXAS (cont.): COMMERCIAL KITCHEN REPAIR CO. 1377 N BRASOS P.O BOX 831128 SAN ANTONIO, TX 78207 (210) 735-2811 800-292-2120 FAX: (210) 735-7421 brock@commercialkitchen.com GCS SERVICE INC.
An important point after buying a device Jackson LT-1 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Jackson LT-1 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Jackson LT-1 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Jackson LT-1 you will learn all the available features of the product, as well as information on its operation. The information that you get Jackson LT-1 will certainly help you make a decision on the purchase.
If you already are a holder of Jackson LT-1, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Jackson LT-1.
However, one of the most important roles played by the user manual is to help in solving problems with Jackson LT-1. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Jackson LT-1 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center