Instruction/ maintenance manual of the product F4 Intermec
Go to page of 83
EasyCoder F4 Bar Code Label Printer Installation & Operation, IPL V er sion P/N 1-960490-02 Edition 3 A ugust 2001.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 1 Preface Pre fac e T able o f Contents ............................................................ ..................... 1 Copyright I nfor mation ...........................
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 2 Pref ace Contents, cont. 6. S et ting Up t he Printer, cont. - Stop B i ts ...................................................................................... 3 5 - P rotocol .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 3 Pref ace Contents, cont. Appendix 1 T e chn ical Dat a ..................................................................... .............. 62 Appendix 2 Media Spe cifi cations .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 4 Pref ace FCC Notice (United States of America) W ARNING Th is e quipment generates, uses, a nd can r adiat e rad io fre quency energy a nd if not in sta lle d and use d in accorda nce wi t h the i ns t ructions ma nual, may cause inter f erence to rad i o commu nications.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 5 Pref ace Dec laration of Conf ormity We , Intermec Printer AB Idrottsv ä gen 10 Bo x 123 S-431 22 M ö lndal Sweden declar.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 6 Chapter 1 Intr oduction The E asyCoder F4 is a st urdy me dium- duty di re ct ther ma l /t her ma l t r a n s fe r p r i n t e r w i t h a p r i n t h e a d r e s ol u t i o n o f 8 d o t s p e r m m (2 03.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 7 Chapter 1 Introduction Safety Precautions Pr oduct Labeling Inter me c assumes no responsibility regard ing t he CE Di rect iv e i f the print er is h andl ed, m odi fi ed , or in sta l led i n a ny w ay other th a n descr ibed i n Inter me c ’ s ma nua ls.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 8 Chapter 2 1 /. T ype an d qua ntit y may var y, or labels /r ibbon ma y be omit- ted completely, dep end ing on area of distribution .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 9 Chapter 2 Installation Fr ont View At the f ront of the pr int er a re t he display windo w , the control la mps, and t he keyboard. T hese featu res a l lo w t he oper ator to control a nd set up the pr i nter ma nual ly .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 10 Chapter 2 Installation Rear Vie w T h e re a r pla t e c ont a i n s t h e O n / O f f swit c h , t he AC power c or d recept acle, and var ious inter face con nector s and slots.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 11 Chapter 2 Installation Media Compar tment The me dia compar tment is either cov ere d b y a long s ide door that compl ete.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 12 Chapter 2 Installation Since the E asyCoder F4 ha s a modula r design, it uses a media suppl y roll post t hat can be fi tted in three diff ere nt pos iti ons insi de th e med ia compar tment.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 13 Chapter 2 Installation Medi a Sup ply Posi t ion s There a re four sets of sl ots a nd t h readed holes in t he pr i nter ’ s center se ct ion for the me d ia supply roll p ost or rot at i ng hub (opt iona l).
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 14 Chapter 2 Installation Print Mechanism The pr int mechan is m featu res a h igh-per forma nce 8 dots-per -m m (2 03 .2 do ts- per - inc h) thermal printh ead wi th qui ck -m oun t fi ttin gs to facilitate rep l aceme nt.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 15 Chapter 2 Installation Connections P ower Computer 1 Place t he pr i nter on a le vel s u r face nea r a n A C outlet.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 16 Chapter 2 Installation Contr ols and Indicator s Control Lamps The E asyCoder F4 ha s sev era l wa ys o f commu nicati ng .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 17 Chapter 2 Installation T he keyboard is of membra ne -switch ty pe a nd has 22 keys. The keyboa rd is sup pleme nt e d by a la rge “ Fee d ” button on t he pr inter ’ s f r o n t .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 18 Chapter 3 Star ting Up Switching On Bef ore switch i ng on the pr i nter, ma ke th e nece ssa r y con nect ions and c h ec k th a t th e p rinth e ad i s e n g a g e d. Swi tch on the pow er usi ng the On / O ff switch on the rea r plate.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 19 Chapter 4 Open the side door . T urn the printhead lift lever cloc kwise to raise the printhead. Media Load T ear-Off (Straight-through) The E asyCoder F4 ca n pr i nt on labels, tickets, tags, a nd continuous stock in var ious forms.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 20 Chapter 5 Ribbon Load 5 T ear-Off , cont. Remove any empty cor e fr om the media supply r oll post. 4 3 6 Route the media thr ough the print mechanism. Then push it inwar ds as far as it will go.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 21 Chapter 4 Media Load T ear-Off , cont. T urn the printhead lift lever counter clockwise to engage the printhead. Adjust the position of the gr een edge guide so the media is guided with a minimum of play .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 22 Chapter 4 Media Load T ear-Off , cont. T o tear off the media, gr ab the outer edge and pull downw ards .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 23 Chapter 4 Media Load T ear-Off with Quic k-Load (Straight-through) In add ition to the med ia lo ad pro cedure for tea r -.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 24 Chapter 4 Media Load T ear-Off with Quic k-Load, cont. If necessary , adjust the outer Quick-Load guide to fi t the width of the media.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 25 Chapter 4 Media Load P eel-Off (Self-str ip) Open the side door . T urn the printhead lift lever cloc kwise to raise the printhead. The E asyCoder F4 ca n pr i nt on labels, tickets, tags, a nd continuous st o c k i n v a r io u s fo r m s .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 26 Chapter 4 Media Load 2 1 4 3 4 2 1 4 3 P eel-Off, cont. Pull out the handle to collapse the takeup hub, then r emove any liner . Remove any empty cor e fr om the media supply r oll post.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 27 Chapter 5 Ribbon Load P eel-Off, cont. Route the liner ar ound the tear bar and the liner drive r oller and back under the print mechanism and guide shaft.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 28 Chapter 5 Ribbon Load P eel-Off, cont. Adjust the position of the gr een edge guide so the media is guided with a minimum of play . 11 12 Close the side door . 13 Pr ess the F eed ke y to advance the media and adjust the media feed.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 29 Chapter 4 Media Load External Suppl y The E asyCoder F4 ca n pr i nt on labels, tickets, tags, a nd continuous stock in var ious forms.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 30 Chapter 5 Ribbon Load Open the side door . 1 T urn the printhead lift lever clockwise to r aise the printhead Thermal T ra.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 31 Chapter 5 Ribbon Load Ribbon Load, cont. Unpack a r oll of original Intermec thermal transfer ribbon. Slide the ribbon r oll onto the supply hub so the ink-coated side faces down when the ribbon is r outed thr ough the print mechanism.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 32 Chapter 6 Setting Up the Printer Ribbon Load, cont. W ithout r eleasing the ribbon, turn the print- head lift lever counter clockwise to engag e the printhead and lock the ribbon.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 33 Chapter 5 Ribbon Load Ribbon Load, cont. T urn the printhead lift knob counter clockwise to engage the printhead.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 34 Chapter 6 Setting Up the Printer Description The set up controls the pr i nter in rega rd of seria l commun ication, test a nd serv ice operat ions, and spe ci fi es which typ es of media a nd r ibbon ar e loaded i n the pr i nter.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 35 Chapter 6 Setting Up the Printer Setup P arameters Serial Communication • Baud Rate • Data Bits • P ar ity • Stop .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 36 Chapter 6 Setting Up the Printer Setup P arameters, cont. Serial Communication, cont. Protocol • XON / XOFF (default) I n the X O N / X O FF proto col, dat a fl ow c on t r ol i s a ch i eve d b y using X ON (D C 1 ) and X OFF ( DC3) cha ra cters.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 37 Chapter 6 Setting Up the Printer Setup P arameters, cont. Serial Communication, cont. Protocol, cont. • Inte rme c St and a rd P ro tocol T he Int er mec P r inter St and a rd P rotocol is a hal f - dupl ex protocol .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 38 Chapter 6 Setting Up the Printer T estprint Th is pa r t of t he Setup Mode a llow s y ou to pr int var ious t yp es of test labels. Go to the desi red opt ion and select whether y ou want to pr int a ll i n format ion or j ust a single f or mat, page, udc , font.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 39 Chapter 6 Setting Up the Printer T estprint, cont. • UDC T he U DC Lab el tests the abil ity of the pr i nter to receiv e a nd pr int si ng le or mu lt iple u s e r-d e fi ne d cha ra ct er s ( bitmap g raph ics) that a re sent f r om t he host.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 40 Chapter 6 Setting Up the Printer The me d ia par a meters t ell t he fi r mw a re t he cha ract erist ics o f t he medi a tha t will b e used, so the p rint o ut will be p o si tio ned c orrec tl y and get t he best qua l ity possible .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 41 Chapter 6 Setting Up the Printer Setup P arameters, cont. Media, cont. Darkness Use this pa ra meter to m ake m inor adjus.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 42 Chapter 7 T o enter t he Set up Mode, press the < Setup > key on the pr inte r ’ s bui lt- in keyboa rd.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 43 Chapter 7 Setup Mode Setup Mode Overview , P ar t 1 Continued on next page SETUP: COMMUNICATION 4800 2400 1200 115200 5760.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 44 Chapter 7 Setup Mode Setup Mode Overview , P ar t 2 Continued from previous page Continued on the next page if an EasyLAN 100i interface board is installed.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 45 Chapter 7 Setup Mode Setup Mode Overview , P ar t 3 • Press <Setup> to exit the Setup Mode. Use <.> and <0> - <9> to set netmask. Use <C> to erase Use <.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 46 Chapter 8 Options Intr oduction The E asyCoder F4 is designed to provide a high degree of fl ex ib i l it y be caus e it has a modu la r d esign. By add i ng options t o t he basic pri nter , the EasyCoder F4 ca n be adapted for a v a riety of app lications.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 47 Chapter 8 Options In t he ded icated d ire ct ther ma l pr int ing (DT P) model, the t her mal tr a nsf er r ibbon mecha nism is om itte d.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 48 Chapter 8 Options For Quick -Load op erat ion ( se e Chapter 4, “ Med ia L oa d ” ), a set of w i d e o r n a r r ow Q u i c k- L o a d g u i d e s i s i n s t a l l e d a t t h e r e a r o f t h e p r i n t mecha nism instea d o f the st anda rd edge gu i de.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 49 Chapter 9 Symptom Possib le Cause Remedy Refer to Over all weak printout Wrong media grade Change parameter Appendix 2, Ch.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 50 Chapter 10 Maintenance Printhead Cleaning Clean ing t he pr int head on a regula r basis is impor ta n t for the li fe of t h e pr i n t h e a d a n d for t he p r i nt o ut q u a l it y .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 51 Chapter 10 Maintenance Printhead Cleaning, cont. Remove any media and transfer ribbon. Open the cleaning car d en velope and pull out the cleaning car d. Read the warning text.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 52 Chapter 10 Maintenance Printhead Cleaning, cont. W ait for appr ox. 30 seconds to allow the cleaning fl uid to dissolve the r esidue. Insert most of the cleaning car d under the printhead (1).
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 53 Chapter 10 Maintenance 1 External Cleaning Always r emove the power cor d befor e cleaning! W ipe external surfaces with a soft cloth slightly moistened with water or a mild deter g ent.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 54 Chapter 10 Maintenance Cleaning the Media Guides Both pa rts of t he label stop sensor , which controls the paper fee d, a re cov ered by tr an spa rent plastic guides.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 55 Chapter 10 Maintenance Printhead Replacement T he pr i nt he ad is subje ct t o wea r b ot h f rom t h e t her ma l t r a n sfer r ibbon or the d ire ct th erm al me dia a nd f rom the rapid heat ing and cooli ng process du r i ng pri nti ng.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 56 Chapter 10 Maintenance Printhead Replacement, cont. Pull the printhead brac ket away fr om the magnet in the pr essure arm. 3 4 Disconnect the printhead brac k et fr om the print mechanism as indicated by the arr ows and pull out the printhead as far as the cables allow .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 57 Chapter 10 Maintenance Printhead Replacement, cont. Connect the two cables to the r eplacement printhead. Put back the printhead in r everse or der and chec k that the printhead cables run fr eely .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 58 Chapter 11 Narr ow Media Adjustment The pr i nter is factor y-ad justed for fu ll-size me dia width.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 59 Chapter 11 Adjustments Label Stop Sensor P osition The lab el stop / black mark sensor ( LSS) is a photo electr ic sensor .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 60 Chapter 11 Adjustments The pressu re of the t her ma l pr int head agai nst the r ibbon or med ia is factory-adjus te d. Ho we v er, the use of th icker or th in ner me dia t ha n norma l could requ i re the pr i nthea d pressure to be rea dj usted.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 61 Chapter 11 Adjustments Ribbon Break Shaft If r i bbo n wr ink ling is occ u rr ing , y ou ma y need to ad ju st the al ign ment of the f ront ribbon brea k shaf t so t hat it ru ns pa ra llel to the pr int head a nd the r ibbon suppl y and rewind hubs.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 62 Appendix 1 Printing Print T ec hnique Thermal T ransfer and / or Direc t Thermal Printhead Resolutio n 8 dots / mm ( 203 .2 d pi) Print Speed (variab le) 1 0 0 to 20 0 mm / sec.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 63 Appendix 1 T echnical Data Sens ors Lab el Gap / Blac k Mark / Out of Med ia Y es 5 fi xe d p o s i ti o n s Printhead Lif ted Y es Ribb on End Y es Controls Control L amps 3 Disp lay 2 x 16 character LCD w .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 64 Appendix 2 Media Speci fi cations Direct Thermal Media I n t e r m e c o f f e r s t w o q u a l i t y g r a d e s o f d .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 65 Appendix 2 Media Speci fi cations Media Roll Size Core Dia meters : 38- 40 m m ( 1 .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 66 Appendix 2 Media Speci fi cations Non-Adhesive Strip Media ⇐ a ⇒ Media Width : Max i mum: 1 1 4.3 m m (4 .50 inches) Mi n imum (sta nd a rd): 25 .0 mm ( 1 .00 i nches) Mi ni mum (na r row Quick -L oad): 40.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 67 Appendix 2 Media Speci fi cations ⇐ a ⇒ Media Width (i nclud i ng l i ne r): Max i mum: 1 1 4.3 mm (4 .50 inches) Mi n imum (sta nd a rd): 25 .0 mm ( 1 .00 i nches) Mi ni mum (na r row Quick -L oad): 40.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 68 Appendix 2 Media Speci fi cations ⇐ a ⇒ Media Width (i nclud i ng l i ne r): Max i mum: 1 1 4.3 m m (4 .50 inches) Mi n imum (sta nd a rd): 25 .0 mm ( 1 .00 i nches) Mi ni mum (na r row Quick -L oad): 40.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 69 Appendix 2 Media Speci fi cations Media, cont. Tickets with Gap ⇐ a ⇒ Media Width : Max i mum: 1 1 4.3 m m (4 .50 inches) Mi n imum (sta nd a rd): 25 .0 mm ( 1 .00 i nches) Mi ni mum (na r row Quick -L oad): 40.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 70 Appendix 2 Media Speci fi cations Media, cont. Tickets with Blac k Mark ⇐ a ⇒ Media Width : Max i mum: 1 1 4.3 m m (4 .50 inches) Mi n imum (sta nd a rd): 25 .0 mm ( 1 .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 71 Appendix 2 Media Speci fi cations Int er me c offer th r ee t yp es of th er ma l t ra nsfer ribbon s opti m i ze d for d.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 72 Appendix 2 Media Speci fi cations 120066102605140 120066102605140 INTERMEC MEDIA PRODUCTS SENSITIVITY LABEL 56 Intermec S.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 73 Appendix 2 Media Specifi cations Setting the Media Sensitivity Number , cont. The sensitivity number on each roll of ther ma l t ra nsfer media or r ibbon has a n a ster isk (* ) i n place of one of the d igits.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 74 Appendix 2 Media Speci fi cations Setting the Media Sensitivity Number , cont.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 75 Appendix 3 Interfaces RS-232 Interface RS-232 P ort T h e E a sy Co d e r F4 h a s, a s st a n d a r d , on e se r ia l c om mu n ica t io n int erf ace: RS - 23 2. Default Communication Setup Baud rate: 960 0 Cha r .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 76 Appendix 3 Interfaces IEEE 1284 P arallel Interface Boar d The E asyCo der F4 can opt ional ly be fi t t e d w i t h a n I E E E 1 2 8 4 - I compatibl e pa ra llel inter face boa rd 1 .
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 77 Appendix 3 Interf aces T he I n te r m e c Ea syL A N 100 i E t he r n et i nt er fac e b oa r d pr ovide s the pr i nter with a 1 0Base T Ether net or 1 0 0Base T X Fast Ether net network connect ion.
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 78 Appendix 4 Suppor ted IPL-3 Commands IP L C o mm a n d S yn tax Abor t Pr i nt Job ..........................................................................................
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 79 Appendix 4 Suppor ted IPL-3 Commands IPL Co mman d S yn tax Fie ld, Delete ..................................................................................................
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 80 Appendix 4 Suppor ted IPL-3 Commands IP L C o mm a n d S yn tax Line Field, Create or Ed it .................................................................................
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 81 Appendix 4 Suppor ted IPL-3 Commands Suppor ted IPL-3 Commands, cont. IPL Co mman d S yn tax T est a nd Ser vice Mode, Exit .................................................
Intermec EasyCoder F4 – Installation & Operation IPL V ersion, Ed. 3 82 Notes.
An important point after buying a device Intermec F4 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Intermec F4 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Intermec F4 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Intermec F4 you will learn all the available features of the product, as well as information on its operation. The information that you get Intermec F4 will certainly help you make a decision on the purchase.
If you already are a holder of Intermec F4, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Intermec F4.
However, one of the most important roles played by the user manual is to help in solving problems with Intermec F4. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Intermec F4 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center