EN
Intel logo
Official user manual

Intel ZT 7102

152 pages·1.4 MB·TV Video Accessories·PDF·ENDEFRITNLJA
Intel ZT 7102
Table of Contents 383 sections Intel® NetStructure™ ZT 7102 Chassis Management Module · Contents · Figures · Tables · … ShowHide
Intel® NetStructure™ ZT 7102 Chassis Management Modulep.1Contentsp.3Figuresp.9Tablesp.10Revision Historyp.121.0 Introductionp.131.1 Overviewp.131.2 ZT 7102 Featuresp.13Figure 1. Functional Block Diagramp.141.3 Terms Used in This Documentp.15Table 1. Glossaryp.152.0 Hardware Specificationsp.172.1 Overviewp.172.2 System Architecturep.18Figure 2. System Management Architecturep.182.3 Backplane Connectionsp.182.3.1 Slot Connectionsp.182.3.2 Chassis Sensor Connectionsp.192.3.3 Chassis FRU Device Connectionsp.192.3.4 Redundancyp.192.4 Power Modulesp.192.5 Fan Modulesp.192.6 Face Platep.20Figure 3. Face Platep.202.6.1 Faceplate Featuresp.21Table 2. Faceplate Featuresp.212.7 Mechanicalp.222.7.1 Board Dimensions and Weightp.22Table 3. Board Dimensions and Weightp.222.7.2 PCB Dimensionsp.22Figure 4. PCB Dimensionsp.222.8 Connectorsp.22Table 4. Connector Assignmentsp.22Figure 5. Connector Locationsp.23Figure 6. Backplane Connectors - Pin Locationsp.232.8.1 J1 Backplane Connectorp.24Table 5. J1 Connector Pinoutp.242.8.2 J2 Backplane Connectorp.24Table 6. J2 Connector Pinoutp.252.8.3 J3 Backplane Connectorp.25Table 7. J3 Connector Pinoutp.252.8.4 Backplane Pin Descriptionsp.26Table 8. Pin Type Definitionsp.26Table 9. Pin Descriptions (Sheet 1 of 2)p.262.8.5 JA1 Ethernet Portp.27Table 10. JA1 Ethernet Port Pinoutp.282.8.6 J6 Serial Portp.28Table 11. J6 Serial Port Pinoutp.282.8.7 J7 Telco Alarm Connectorp.28Table 12. J7 Telco Alarm Connector Pinoutp.292.9 Electrical and Environmentalp.292.9.1 CMM Powerp.29Table 13. CMM Power Availabilityp.292.9.2 Power Ramp Circuitryp.302.9.3 Operating Temperaturep.302.9.4 Reliabilityp.302.9.5 Absolute Maximum Ratingsp.30Table 14. Absolute Maximum Ratingsp.302.9.6 DC Operating Characteristicsp.31Table 15. DC Operating Characteristicsp.312.10 Onboard Switchesp.31Table 16. Switch Cross Reference Tablep.31Figure 7. Default Switch Configurationp.312.10.1 Switch Descriptionsp.322.10.1.1 S1 (Alarm Cutoff and Board Reset)p.322.10.1.2 SW1-1 (Password Reset)p.32Table 17. SW1-1 Functionsp.322.11 Processor and Chipsetp.322.12 Memoryp.332.12.1 Removing the SODIMMp.332.12.2 Installing Memoryp.332.13 Flashp.332.14 Dual Ethernet Controllersp.332.15 Serial I/Op.332.16 Telco Alarm Signalp.342.16.1 Alarm Relaysp.342.16.2 Opto Inputsp.342.17 Real Time Clockp.342.18 Network Time Synchronizationp.342.19 Watchdog Timerp.352.20 Battery Backupp.352.20.1 Replacing the Batteryp.35Table 18. Battery Characteristicsp.352.21 Running Your System Without A CMMp.363.0 Software Specificationsp.373.1 Operating Systemp.373.2 Command Line Interface (CLI)p.373.3 SNMP/UDPp.373.4 Remote Procedure Call (RPC) Interfacep.373.5 Ethernet Interfacesp.373.6 Sensor Event Logs (SEL)p.383.6.1 CMM SEL Architecturep.383.6.2 Satellite Management Controller (SMC) Boardsp.383.6.3 Baseboard Management Controller (BMC) Boardsp.383.6.4 Retrieving a SELp.384.0 CMM Redundancy, Synchronization and Failoverp.394.1 Overviewp.394.2 Hardware Redundancy Specificationp.394.3 Synchronizationp.39Table 19. CMM Synchronizationp.404.3.1 Synchronization Requirementsp.404.4 CMM Failoverp.414.4.1 Scenarios That Force a Failoverp.414.4.2 Scenarios That Prevent Failoverp.414.4.3 Scenarios That Failover to a Healthier Standby CMMp.414.4.4 Scenarios That Failover to an Equally Healthy CMMp.424.4.5 Failover Timingp.424.4.6 Manual Failoverp.425.0 CMM Installation and Removalp.435.1 Unpackingp.435.2 Connectivityp.435.3 Installing the CMMp.43Figure 8. Ejector Handle Operationp.445.4 Removing the CMMp.446.0 Built-In Self Testp.476.1 BIST Test Flowp.47Figure 9. BIST Flow Chartp.47Table 20. BIST Implementationp.486.2 Boot-BISTp.486.3 Early-BISTp.486.4 Mid-BISTp.486.5 Late-BISTp.49Figure 10. Timing of BIST Stagesp.496.6 Event Log Area and Event Managementp.496.7 OS Flash Corruption Detection and Recovery Designp.506.7.1 Monitoring the Static Imagesp.506.7.2 Monitoring the Dynamic Imagesp.506.7.3 CMM Failoverp.506.8 BIST Test Descriptionsp.516.8.1 Flash Checksum Testp.516.8.2 Base Memory Testp.516.8.3 Extended Memory Testsp.516.8.3.1 Walking Ones Testp.516.8.3.2 32-Bit Address Testp.516.8.3.3 32-Bit Inverse Address Testp.516.8.4 FPGA Version Checkp.526.8.5 DS1307 RTC Testp.526.8.6 NIC Presence/Local PCI Bus Testp.526.8.7 OS Image Checksum Testp.526.8.8 CRC32 Checksump.526.8.9 IPMB Bus Busy/Not Ready Testp.527.0 CMM Connection and Setupp.537.1 CLI Overviewp.537.2 Connecting to the CLIp.537.2.1 Connecting through a Consolep.537.2.2 Telnet into the CMMp.537.2.3 FTP Into the CMMp.547.3 Initial Setup - Logging in for the First Timep.547.3.1 Setting IP Address Propertiesp.547.3.1.1 Setting IP Information (IP Address, Netmask, and Gateway)p.557.3.1.2 Setting Eth0 to DHCPp.557.3.2 Setting a Hostnamep.567.3.3 Setting Auto-Logout Time Limitp.567.3.4 Rebooting the CMMp.568.0 Command Line Interface (CLI) Syntax and Argumentsp.578.1 cmmget and cmmset syntaxp.578.2 Help Parameter: -hp.578.3 Location Parameter: -lp.57Table 21. Location (-l) Keywordsp.578.4 Target Parameter: -tp.58Table 22. Target (-t) Keywordsp.588.5 Dataitem Parameter: -dp.58Table 23. dataitem (-d) Keywords for All Locations (Sheet 1 of 2)p.58Table 24. dataitem (-d) Keywords for System locationp.59Table 25. dataitem (-d) Keywords for BladeN Locationsp.59Table 26. dataitem (-d) Keywords for Chassis Locationp.60Table 27. dataitem (-d) Keywords for CMM Location (Sheet 1 of 2)p.608.6 Value Parameter: -vp.618.7 Sample CLI Operationsp.618.8 Generating a System Status Reportp.629.0 Resetting the Passwordp.639.1 Resetting the Password in a Single CMM Systemp.639.2 Resetting the Password in a Dual CMM Systemp.6310.0 Sensor Typesp.6510.1 Threshold-Based Sensorsp.6510.1.1 Threshold-Based Sensor Eventsp.6510.2 Discrete Sensorsp.6510.2.1 Discrete Sensor Eventsp.6511.0 Health Event Stringsp.6711.1 Syntax of Health Event Stringsp.6711.1.1 “healthevents” Query Event Syntaxp.6711.1.2 SEL Event Syntaxp.6711.1.3 SNMP Trap Event Syntaxp.6811.2 Sensor Targetsp.68Table 28. CMM Sensor Targetsp.6811.3 Healthevents Queriesp.6911.3.1 HealthEvents Queries for Individual Sensorsp.6911.3.2 HealthEvents Queries for All Sensors on a Locationp.6911.3.3 No Active Eventsp.6911.3.4 Not Present or Non-IPMI Locationsp.7011.4 List of Possible Health Event Stringsp.7011.4.1 All Locationsp.71Table 29. Threshold-Based Sensor Event Strings (Voltage, Temp, Current, Fan)p.7111.4.2 PowerSupplyN Location (IPMI-Compliant Supplies Only)p.71Table 30. Power Supply Event Strings (PowerSupplyN)p.7111.4.3 CMM Locationp.72Table 31. BIST Event Strings (BIST) (Sheet 1 of 2)p.72Table 32. Telco Alarm Sensor Event Strings (TASensor[1,2])p.73Table 33. LAN Sensor Event Strings (Eth[0,1,1:1] Interface)p.7311.4.4 Chassis Locationp.73Table 34. Fan Tray Presence Event Strings (Fan Tray [1-3] Presence)p.73Table 35. Chassis Power Supply Event Strings (Pwr Supply N)p.73Table 36. Slot Event Strings (Slot N Event)p.74Table 37. CMM Redundancy Event Strings (CMM [1-2] Redundancy)p.74Table 38. CMM Failover Event Strings (CMM Failover)p.74Table 39. CMM File Sync Event Strings (CMM File Sync)p.75Table 40. Chassis Sensor Event Stringsp.7512.0 Slot Power Controlp.7712.1 Difference between a Board’s HEALTHY# Signal and a Board’s Healthp.7712.2 Slot Power-Up Sequencep.7712.2.1 Assertion of BD_SEL#p.7712.2.1.1 System Master Boardsp.7712.2.1.2 Peripheral Boardsp.7712.2.1.3 Fabric and PCI-Less Slotsp.7812.2.1.4 Drone Mode Boardsp.7812.2.2 Assertion of HEALTHY# During Power-Upp.7812.3 Obtaining the Power State of a Boardp.7812.4 Controlling the Power State of a Slotp.7912.4.1 Powering Off a Boardp.7912.4.2 Powering On a Boardp.7912.4.3 Resetting a Boardp.7912.5 Power Sequencing Commands and Policiesp.7912.5.1 Retrieving the Healthy# Ramp-Up Timep.8012.5.2 Setting the Healthy# Ramp-Up Timep.8012.5.3 Retrieving the Maximum Power-Up Attemptsp.8012.5.4 Setting the Maximum Power-Up Attemptsp.8012.5.5 Power Sequencing SEL Eventsp.8113.0 Power Suppliesp.8313.1 Power Supply Detectionp.8313.2 Inhibit, Degrade, and Fail Signalsp.8313.3 Inhibiting Power Suppliesp.8313.4 Precautions For Inhibiting Power Suppliesp.8313.5 Inhibiting Power Suppliesp.8413.6 Enabling Power Suppliesp.8414.0 Drone Mode SBC Supportp.8514.0.1 Adding a Drone Mode Capable SBCp.8514.0.2 Removing a Drone Mode Capable SBCp.8515.0 Active vs. Offline Slotsp.8715.1 Determining the State of a Slotp.8715.2 Setting a Slot to Offline Modep.8715.3 Setting a Slot to Active Modep.8715.4 Limitations of the Offline Modep.8716.0 Obtaining FRU Informationp.8916.1 FRU Informationp.8916.2 FRU Query Syntaxp.89Table 41. Dataitems Used With FRU Target (-t) to Obtain FRU Information (Sheet 1 of 2)p.8916.3 Chassis FRU Validity Checkp.9017.0 Fan Control and Monitoringp.9117.1 Setting Fan Speedp.9117.1.1 Considerations for Turning Off the Fansp.9117.2 Automatic Fan Controlp.9117.3 Querying Fan Tray Sensorsp.9218.0 CMM Scriptingp.9318.1 CLI Scriptingp.9318.1.1 Script Synchronizationp.9318.2 Associating Scripts to Event Severityp.9318.2.1 Listing Scripts Associated With Eventsp.9418.2.2 Removing Scripts From an Associated Eventp.9418.3 Setting Scripts for Specific Individual Eventsp.9418.3.1 Event Codesp.9418.4 Setting Event Scriptsp.9518.5 Slot Eventsp.9519.0 SNMPp.97Figure 11. High Level SNMP/MIB Layoutp.9719.1 CMM MIBp.9819.2 MIB Designp.98Table 42. MIB II Objects - System Groupp.98Table 43. MIB II - Interface Groupp.9819.2.1 CMM MIB Objectsp.9819.2.2 Querying Non-IPMI Compliant Blades and Power Suppliesp.9819.3 SNMP Agentp.9819.3.1 Configuring the SNMP Agent Portp.9919.3.2 Configuring the Agent to Respond to SNMP v3 Requestsp.9919.3.3 Configuring the Agent Back to SNMP v1p.9919.3.4 Setting up an SNMP v3 MIB Browserp.9919.4 SNMP Trap Utilityp.10019.4.1 Configuring the SNMP Trap Portp.10019.4.2 Configuring the CMM to Send SNMP v3 Trapsp.10019.4.3 Configuring the CMM to Send SNMP v1 Trapsp.10019.5 Configuring and Enabling SNMP Trap Addressesp.10019.5.1 Configuring an SNMP Trap Addressp.10019.5.2 Enabling and Disabling SNMP Trapsp.10019.5.3 Alerts Using SNMPv3p.10119.5.4 Alert Using UDP Alertp.10119.6 Security Modelp.10119.6.1 SNMPv3 Security: Authentication Protocol and Privacy Protocolp.101Table 44. SNMPv3 Security Fieldsp.10119.7 snmpd.confp.10120.0 RPCp.10320.1 Setting Up the RPC Interfacep.10320.2 Using the RPC Interfacep.10320.2.1 GetAuthCapability()p.10420.2.2 ChassisManagementApi()p.104Table 45. Error and Return Codes for the RPC Interface (Sheet 1 of 4)p.10620.2.3 ChassisManagementApi() Threshold Response Formatp.109Table 46. Threshold Response Formatsp.11020.2.4 ChassisManagementApi() String Response Formatp.110Table 47. String Response Formats (Sheet 1 of 4)p.11020.2.5 ChassisManagementApi() Integer Response Formatp.113Table 48. Integer Response Formats (Sheet 1 of 2)p.11320.2.6 FRU String Response Formatp.114Table 49. FRU Data Items String Response Format (Sheet 1 of 2)p.11420.3 RPC Sample Codep.11520.4 RPC Usage Examplesp.115Table 50. RPC Usage Examples (Sheet 1 of 3)p.11621.0 Command Loggingp.11922.0 Telco Alarm Sensorsp.12122.1 Configuring the Telco Alarm Connector Pinsp.12122.2 Obtaining the Configuration of the Telco Alarm Sensor Connector Pinsp.12122.3 Telco Alarm Connector Sensor Namingp.12122.3.1 Sensor Names using SNMPp.12222.4 Telco Alarm Sensors and Redundancyp.12223.0 Application Hostingp.12323.1 System Detailsp.12323.2 Startup and Shutdown Scriptsp.12323.3 System Resources Available to User Applicationsp.12323.3.1 File System Storage Constraintsp.12323.3.1.1 Flash Storage Locationsp.12323.3.1.2 RAM-Disk Storage Locationsp.12423.3.2 RAM Constraintsp.12423.3.3 Interrupt Constraintsp.12423.4 Ram Disk Directory Structurep.12424.0 Busless Backplane Supportp.12525.0 Updating Softwarep.12725.1 Key Features of the Firmware Update Processp.12725.2 Update Process Architecturep.12725.3 Critical Software Update Files and Directoriesp.128Table 51. List of Critical Software Update Files and Directoriesp.12825.4 Update Packagep.128Table 52. Contents of the Update Package (Sheet 1 of 2)p.12825.4.1 Update Package File Validationp.12925.4.2 Update Firmware Package Versionp.12925.4.3 Component Versioningp.13025.5 saveList and Data Preservationp.130Table 53. saveList Items and Their Priorities (Sheet 1 of 2)p.13025.6 Update Modep.13125.7 Update_Metadata Filep.13125.8 Synchronizationp.132Table 54. Synchronization Behavior for Differing Synch Versionsp.13225.8.1 Updating to a Newer Synchronization Versionp.13225.8.2 Updating to an Older Synchronization Versionp.13225.8.3 Updating to the Same Synchronization Versionp.13325.9 Single CMM Systemp.13325.10 Redundant CMM Systemsp.13325.11 CLI Supportp.13325.12 Hooks for User Scriptsp.13425.12.1 Update Mode User Scriptsp.13425.12.2 Data Restore User Scripts.p.13425.12.3 Example Task - Replace /home/scripts/myScript with a newer version if updating forward or an older version if updating backwardp.13525.13 Update Processp.13625.14 Update Process Status and Loggingp.13725.15 DEBUG_UPDATE Variablep.13725.16 Update Process Sensor and SEL Eventsp.13725.17 RedBoot Update Processp.13825.17.1 Required Setupp.13825.17.2 Update Procedurep.138Appendix D Example CLI Commandsp.139Table 55. Example CLI Commands (Sheet 1 of 2)p.139Appendix E Datasheet Referencep.141E.1 Intel® CompactPCI* Product Informationp.141E.2 CompactPCIp.141E.3 IPMIp.141E.4 Intel® IOP310 Processor Chipsetp.141Appendix F Warranty Informationp.143F.1 Intel® NetStructure™ Compute Boards & Platform Products Limited Warrantyp.143F.1.1 Returning a Defective Product (RMA)p.143F.1.2 For the Americasp.143F.1.3 For EMEAp.144F.1.4 For APACp.144Appendix G Customer Supportp.147G.2 Technical Support and Return for Service Assistancep.147G.3 Sales Assistancep.147Appendix H Agency Approvalsp.149H.1 CE Certificationp.149H.2 Safetyp.149H.3 Emissions Test Regulationsp.149H.3.5 EN 50081-1 Emissionsp.149H.3.6 EN 55024 Immunityp.149H.4 Regulatory Informationp.150H.4.7 FCC (USA)p.150H.4.8 Industry Canada (Canada)p.150H.5 Product Safety Informationp.150H.5.8.1 Safety Precautionsp.150
Page 1 of the Intel ZT 7102 user manual — August 2004
Page 1 · click to enlarge
Page 1

Intel ® NetStructure™ ZT 7102 Chassis Management Module

August 2004

Order Number273770-017
Page 2 of the Intel ZT 7102 user manual — Intel® NetStructure™ ZT 7102 Chassis Management Module
Page 2 · click to enlarge
Page 2

Intel® NetStructure™ ZT 7102 Chassis Management Module

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER, AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. Intel products are not intended for use in medical, life saving, life sustaining applications.

Intel may make changes to specifications and product descriptions at any time, without notice.

Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them.

Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order.

Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800- 548-4725, or by visiting Intel's website at http://www.intel.com

AlertVIEW, AnyPoint, AppChoice, BoardWatch, BunnyPeople, CablePort, Celeron, Chips, CT Connect, CT Media, Dialogic, DM3, EtherExpress, ETOX, FlashFile, i386, i486, i960, iCOMP, InstantIP, Intel, Intel logo, Intel386, Intel486, Intel740, IntelDX2, IntelDX4, IntelSX2, Intel Create & Share, Intel GigaBlade, Intel InBusiness, Intel Inside, Intel Inside logo, Intel NetBurst, Intel NetMerge, Intel NetStructure, Intel Play, Intel Play logo, Intel SingleDriver, Intel SpeedStep, Intel StrataFlash, Intel TeamStation, Intel Xeon, Intel XScale, IPLink, Itanium, LANDesk, LanRover, MCS, MMX, MMX logo, Optimizer logo, OverDrive, Paragon, PC Dads, PC Parents, PDCharm, Pentium, Pentium II Xeon, Pentium III Xeon, Performance at Your Command, RemoteExpress, Shiva, SmartDie, Solutions960, Sound Mark, StorageExpress, The Computer Inside., The Journey Inside, TokenExpress, Trillium, VoiceBrick, Vtune, and Xircom are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

*Other names and brands may be claimed as the property of others.

Copyright © Intel Corporation 2004.

Page 3 of the Intel ZT 7102 user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Intel® NetStructure™ ZT 7102 Chassis Management Modulep.1Contentsp.3Figuresp.9Tablesp.10Revision Historyp.121.0 Introductionp.131.1 Overviewp.131.2 ZT 7102 Featuresp.13Figure 1. Functional Block Diagramp.141.3 Terms Used in This Documentp.15Table 1. Glossaryp.152.0 Hardware Specificationsp.172.1 Overviewp.172.2 System Architecturep.18Figure 2. System Management Architecturep.182.3 Backplane Connectionsp.182.3.1 Slot Connectionsp.182.3.2 Chassis Sensor Connectionsp.192.3.3 Chassis FRU Device Connectionsp.192.3.4 Redundancyp.192.4 Power Modulesp.192.5 Fan Modulesp.192.6 Face Platep.20Figure 3. Face Platep.202.6.1 Faceplate Featuresp.21Table 2. Faceplate Featuresp.212.7 Mechanicalp.222.7.1 Board Dimensions and Weightp.22Table 3. Board Dimensions and Weightp.222.7.2 PCB Dimensionsp.22Figure 4. PCB Dimensionsp.222.8 Connectorsp.22Table 4. Connector Assignmentsp.22Figure 5. Connector Locationsp.23Figure 6. Backplane Connectors - Pin Locationsp.232.8.1 J1 Backplane Connectorp.24Table 5. J1 Connector Pinoutp.242.8.2 J2 Backplane Connectorp.24Table 6. J2 Connector Pinoutp.252.8.3 J3 Backplane Connectorp.25Table 7. J3 Connector Pinoutp.252.8.4 Backplane Pin Descriptionsp.26Table 8. Pin Type Definitionsp.26Table 9. Pin Descriptions (Sheet 1 of 2)p.262.8.5 JA1 Ethernet Portp.27Table 10. JA1 Ethernet Port Pinoutp.282.8.6 J6 Serial Portp.28Table 11. J6 Serial Port Pinoutp.282.8.7 J7 Telco Alarm Connectorp.28Table 12. J7 Telco Alarm Connector Pinoutp.292.9 Electrical and Environmentalp.292.9.1 CMM Powerp.29Table 13. CMM Power Availabilityp.292.9.2 Power Ramp Circuitryp.302.9.3 Operating Temperaturep.302.9.4 Reliabilityp.302.9.5 Absolute Maximum Ratingsp.30Table 14. Absolute Maximum Ratingsp.302.9.6 DC Operating Characteristicsp.31Table 15. DC Operating Characteristicsp.312.10 Onboard Switchesp.31Table 16. Switch Cross Reference Tablep.31Figure 7. Default Switch Configurationp.312.10.1 Switch Descriptionsp.322.10.1.1 S1 (Alarm Cutoff and Board Reset)p.322.10.1.2 SW1-1 (Password Reset)p.32Table 17. SW1-1 Functionsp.322.11 Processor and Chipsetp.322.12 Memoryp.332.12.1 Removing the SODIMMp.332.12.2 Installing Memoryp.332.13 Flashp.332.14 Dual Ethernet Controllersp.332.15 Serial I/Op.332.16 Telco Alarm Signalp.342.16.1 Alarm Relaysp.342.16.2 Opto Inputsp.342.17 Real Time Clockp.342.18 Network Time Synchronizationp.342.19 Watchdog Timerp.352.20 Battery Backupp.352.20.1 Replacing the Batteryp.35Table 18. Battery Characteristicsp.352.21 Running Your System Without A CMMp.363.0 Software Specificationsp.373.1 Operating Systemp.373.2 Command Line Interface (CLI)p.373.3 SNMP/UDPp.373.4 Remote Procedure Call (RPC) Interfacep.373.5 Ethernet Interfacesp.373.6 Sensor Event Logs (SEL)p.383.6.1 CMM SEL Architecturep.383.6.2 Satellite Management Controller (SMC) Boardsp.383.6.3 Baseboard Management Controller (BMC) Boardsp.383.6.4 Retrieving a SELp.384.0 CMM Redundancy, Synchronization and Failoverp.394.1 Overviewp.394.2 Hardware Redundancy Specificationp.394.3 Synchronizationp.39Table 19. CMM Synchronizationp.404.3.1 Synchronization Requirementsp.404.4 CMM Failoverp.414.4.1 Scenarios That Force a Failoverp.414.4.2 Scenarios That Prevent Failoverp.414.4.3 Scenarios That Failover to a Healthier Standby CMMp.414.4.4 Scenarios That Failover to an Equally Healthy CMMp.424.4.5 Failover Timingp.424.4.6 Manual Failoverp.425.0 CMM Installation and Removalp.435.1 Unpackingp.435.2 Connectivityp.435.3 Installing the CMMp.43Figure 8. Ejector Handle Operationp.445.4 Removing the CMMp.446.0 Built-In Self Testp.476.1 BIST Test Flowp.47Figure 9. BIST Flow Chartp.47Table 20. BIST Implementationp.486.2 Boot-BISTp.486.3 Early-BISTp.486.4 Mid-BISTp.486.5 Late-BISTp.49Figure 10. Timing of BIST Stagesp.496.6 Event Log Area and Event Managementp.496.7 OS Flash Corruption Detection and Recovery Designp.506.7.1 Monitoring the Static Imagesp.506.7.2 Monitoring the Dynamic Imagesp.506.7.3 CMM Failoverp.506.8 BIST Test Descriptionsp.516.8.1 Flash Checksum Testp.516.8.2 Base Memory Testp.516.8.3 Extended Memory Testsp.516.8.3.1 Walking Ones Testp.516.8.3.2 32-Bit Address Testp.516.8.3.3 32-Bit Inverse Address Testp.516.8.4 FPGA Version Checkp.526.8.5 DS1307 RTC Testp.526.8.6 NIC Presence/Local PCI Bus Testp.526.8.7 OS Image Checksum Testp.526.8.8 CRC32 Checksump.526.8.9 IPMB Bus Busy/Not Ready Testp.527.0 CMM Connection and Setupp.537.1 CLI Overviewp.537.2 Connecting to the CLIp.537.2.1 Connecting through a Consolep.537.2.2 Telnet into the CMMp.537.2.3 FTP Into the CMMp.547.3 Initial Setup - Logging in for the First Timep.547.3.1 Setting IP Address Propertiesp.547.3.1.1 Setting IP Information (IP Address, Netmask, and Gateway)p.557.3.1.2 Setting Eth0 to DHCPp.557.3.2 Setting a Hostnamep.567.3.3 Setting Auto-Logout Time Limitp.567.3.4 Rebooting the CMMp.568.0 Command Line Interface (CLI) Syntax and Argumentsp.578.1 cmmget and cmmset syntaxp.578.2 Help Parameter: -hp.578.3 Location Parameter: -lp.57Table 21. Location (-l) Keywordsp.578.4 Target Parameter: -tp.58Table 22. Target (-t) Keywordsp.588.5 Dataitem Parameter: -dp.58Table 23. dataitem (-d) Keywords for All Locations (Sheet 1 of 2)p.58Table 24. dataitem (-d) Keywords for System locationp.59Table 25. dataitem (-d) Keywords for BladeN Locationsp.59Table 26. dataitem (-d) Keywords for Chassis Locationp.60Table 27. dataitem (-d) Keywords for CMM Location (Sheet 1 of 2)p.608.6 Value Parameter: -vp.618.7 Sample CLI Operationsp.618.8 Generating a System Status Reportp.629.0 Resetting the Passwordp.639.1 Resetting the Password in a Single CMM Systemp.639.2 Resetting the Password in a Dual CMM Systemp.6310.0 Sensor Typesp.6510.1 Threshold-Based Sensorsp.6510.1.1 Threshold-Based Sensor Eventsp.6510.2 Discrete Sensorsp.6510.2.1 Discrete Sensor Eventsp.6511.0 Health Event Stringsp.6711.1 Syntax of Health Event Stringsp.6711.1.1 “healthevents” Query Event Syntaxp.6711.1.2 SEL Event Syntaxp.6711.1.3 SNMP Trap Event Syntaxp.6811.2 Sensor Targetsp.68Table 28. CMM Sensor Targetsp.6811.3 Healthevents Queriesp.6911.3.1 HealthEvents Queries for Individual Sensorsp.6911.3.2 HealthEvents Queries for All Sensors on a Locationp.6911.3.3 No Active Eventsp.6911.3.4 Not Present or Non-IPMI Locationsp.7011.4 List of Possible Health Event Stringsp.7011.4.1 All Locationsp.71Table 29. Threshold-Based Sensor Event Strings (Voltage, Temp, Current, Fan)p.7111.4.2 PowerSupplyN Location (IPMI-Compliant Supplies Only)p.71Table 30. Power Supply Event Strings (PowerSupplyN)p.7111.4.3 CMM Locationp.72Table 31. BIST Event Strings (BIST) (Sheet 1 of 2)p.72Table 32. Telco Alarm Sensor Event Strings (TASensor[1,2])p.73Table 33. LAN Sensor Event Strings (Eth[0,1,1:1] Interface)p.7311.4.4 Chassis Locationp.73Table 34. Fan Tray Presence Event Strings (Fan Tray [1-3] Presence)p.73Table 35. Chassis Power Supply Event Strings (Pwr Supply N)p.73Table 36. Slot Event Strings (Slot N Event)p.74Table 37. CMM Redundancy Event Strings (CMM [1-2] Redundancy)p.74Table 38. CMM Failover Event Strings (CMM Failover)p.74Table 39. CMM File Sync Event Strings (CMM File Sync)p.75Table 40. Chassis Sensor Event Stringsp.7512.0 Slot Power Controlp.7712.1 Difference between a Board’s HEALTHY# Signal and a Board’s Healthp.7712.2 Slot Power-Up Sequencep.7712.2.1 Assertion of BD_SEL#p.7712.2.1.1 System Master Boardsp.7712.2.1.2 Peripheral Boardsp.7712.2.1.3 Fabric and PCI-Less Slotsp.7812.2.1.4 Drone Mode Boardsp.7812.2.2 Assertion of HEALTHY# During Power-Upp.7812.3 Obtaining the Power State of a Boardp.7812.4 Controlling the Power State of a Slotp.7912.4.1 Powering Off a Boardp.7912.4.2 Powering On a Boardp.7912.4.3 Resetting a Boardp.7912.5 Power Sequencing Commands and Policiesp.7912.5.1 Retrieving the Healthy# Ramp-Up Timep.8012.5.2 Setting the Healthy# Ramp-Up Timep.8012.5.3 Retrieving the Maximum Power-Up Attemptsp.8012.5.4 Setting the Maximum Power-Up Attemptsp.8012.5.5 Power Sequencing SEL Eventsp.8113.0 Power Suppliesp.8313.1 Power Supply Detectionp.8313.2 Inhibit, Degrade, and Fail Signalsp.8313.3 Inhibiting Power Suppliesp.8313.4 Precautions For Inhibiting Power Suppliesp.8313.5 Inhibiting Power Suppliesp.8413.6 Enabling Power Suppliesp.8414.0 Drone Mode SBC Supportp.8514.0.1 Adding a Drone Mode Capable SBCp.8514.0.2 Removing a Drone Mode Capable SBCp.8515.0 Active vs. Offline Slotsp.8715.1 Determining the State of a Slotp.8715.2 Setting a Slot to Offline Modep.8715.3 Setting a Slot to Active Modep.8715.4 Limitations of the Offline Modep.8716.0 Obtaining FRU Informationp.8916.1 FRU Informationp.8916.2 FRU Query Syntaxp.89Table 41. Dataitems Used With FRU Target (-t) to Obtain FRU Information (Sheet 1 of 2)p.8916.3 Chassis FRU Validity Checkp.9017.0 Fan Control and Monitoringp.9117.1 Setting Fan Speedp.9117.1.1 Considerations for Turning Off the Fansp.9117.2 Automatic Fan Controlp.9117.3 Querying Fan Tray Sensorsp.9218.0 CMM Scriptingp.9318.1 CLI Scriptingp.9318.1.1 Script Synchronizationp.9318.2 Associating Scripts to Event Severityp.9318.2.1 Listing Scripts Associated With Eventsp.9418.2.2 Removing Scripts From an Associated Eventp.9418.3 Setting Scripts for Specific Individual Eventsp.9418.3.1 Event Codesp.9418.4 Setting Event Scriptsp.9518.5 Slot Eventsp.9519.0 SNMPp.97Figure 11. High Level SNMP/MIB Layoutp.9719.1 CMM MIBp.9819.2 MIB Designp.98Table 42. MIB II Objects - System Groupp.98Table 43. MIB II - Interface Groupp.9819.2.1 CMM MIB Objectsp.9819.2.2 Querying Non-IPMI Compliant Blades and Power Suppliesp.9819.3 SNMP Agentp.9819.3.1 Configuring the SNMP Agent Portp.9919.3.2 Configuring the Agent to Respond to SNMP v3 Requestsp.9919.3.3 Configuring the Agent Back to SNMP v1p.9919.3.4 Setting up an SNMP v3 MIB Browserp.9919.4 SNMP Trap Utilityp.10019.4.1 Configuring the SNMP Trap Portp.10019.4.2 Configuring the CMM to Send SNMP v3 Trapsp.10019.4.3 Configuring the CMM to Send SNMP v1 Trapsp.10019.5 Configuring and Enabling SNMP Trap Addressesp.10019.5.1 Configuring an SNMP Trap Addressp.10019.5.2 Enabling and Disabling SNMP Trapsp.10019.5.3 Alerts Using SNMPv3p.10119.5.4 Alert Using UDP Alertp.10119.6 Security Modelp.10119.6.1 SNMPv3 Security: Authentication Protocol and Privacy Protocolp.101Table 44. SNMPv3 Security Fieldsp.10119.7 snmpd.confp.10120.0 RPCp.10320.1 Setting Up the RPC Interfacep.10320.2 Using the RPC Interfacep.10320.2.1 GetAuthCapability()p.10420.2.2 ChassisManagementApi()p.104Table 45. Error and Return Codes for the RPC Interface (Sheet 1 of 4)p.10620.2.3 ChassisManagementApi() Threshold Response Formatp.109Table 46. Threshold Response Formatsp.11020.2.4 ChassisManagementApi() String Response Formatp.110Table 47. String Response Formats (Sheet 1 of 4)p.11020.2.5 ChassisManagementApi() Integer Response Formatp.113Table 48. Integer Response Formats (Sheet 1 of 2)p.11320.2.6 FRU String Response Formatp.114Table 49. FRU Data Items String Response Format (Sheet 1 of 2)p.11420.3 RPC Sample Codep.11520.4 RPC Usage Examplesp.115Table 50. RPC Usage Examples (Sheet 1 of 3)p.11621.0 Command Loggingp.11922.0 Telco Alarm Sensorsp.12122.1 Configuring the Telco Alarm Connector Pinsp.12122.2 Obtaining the Configuration of the Telco Alarm Sensor Connector Pinsp.12122.3 Telco Alarm Connector Sensor Namingp.12122.3.1 Sensor Names using SNMPp.12222.4 Telco Alarm Sensors and Redundancyp.12223.0 Application Hostingp.12323.1 System Detailsp.12323.2 Startup and Shutdown Scriptsp.12323.3 System Resources Available to User Applicationsp.12323.3.1 File System Storage Constraintsp.12323.3.1.1 Flash Storage Locationsp.12323.3.1.2 RAM-Disk Storage Locationsp.12423.3.2 RAM Constraintsp.12423.3.3 Interrupt Constraintsp.12423.4 Ram Disk Directory Structurep.12424.0 Busless Backplane Supportp.12525.0 Updating Softwarep.12725.1 Key Features of the Firmware Update Processp.12725.2 Update Process Architecturep.12725.3 Critical Software Update Files and Directoriesp.128Table 51. List of Critical Software Update Files and Directoriesp.12825.4 Update Packagep.128Table 52. Contents of the Update Package (Sheet 1 of 2)p.12825.4.1 Update Package File Validationp.12925.4.2 Update Firmware Package Versionp.12925.4.3 Component Versioningp.13025.5 saveList and Data Preservationp.130Table 53. saveList Items and Their Priorities (Sheet 1 of 2)p.13025.6 Update Modep.13125.7 Update_Metadata Filep.13125.8 Synchronizationp.132Table 54. Synchronization Behavior for Differing Synch Versionsp.13225.8.1 Updating to a Newer Synchronization Versionp.13225.8.2 Updating to an Older Synchronization Versionp.13225.8.3 Updating to the Same Synchronization Versionp.13325.9 Single CMM Systemp.13325.10 Redundant CMM Systemsp.13325.11 CLI Supportp.13325.12 Hooks for User Scriptsp.13425.12.1 Update Mode User Scriptsp.13425.12.2 Data Restore User Scripts.p.13425.12.3 Example Task - Replace /home/scripts/myScript with a newer version if updating forward or an older version if updating backwardp.13525.13 Update Processp.13625.14 Update Process Status and Loggingp.13725.15 DEBUG_UPDATE Variablep.13725.16 Update Process Sensor and SEL Eventsp.13725.17 RedBoot Update Processp.13825.17.1 Required Setupp.13825.17.2 Update Procedurep.138Appendix D Example CLI Commandsp.139Table 55. Example CLI Commands (Sheet 1 of 2)p.139Appendix E Datasheet Referencep.141E.1 Intel® CompactPCI* Product Informationp.141E.2 CompactPCIp.141E.3 IPMIp.141E.4 Intel® IOP310 Processor Chipsetp.141Appendix F Warranty Informationp.143F.1 Intel® NetStructure™ Compute Boards & Platform Products Limited Warrantyp.143F.1.1 Returning a Defective Product (RMA)p.143F.1.2 For the Americasp.143F.1.3 For EMEAp.144F.1.4 For APACp.144Appendix G Customer Supportp.147G.2 Technical Support and Return for Service Assistancep.147G.3 Sales Assistancep.147Appendix H Agency Approvalsp.149H.1 CE Certificationp.149H.2 Safetyp.149H.3 Emissions Test Regulationsp.149H.3.5 EN 50081-1 Emissionsp.149H.3.6 EN 55024 Immunityp.149H.4 Regulatory Informationp.150H.4.7 FCC (USA)p.150H.4.8 Industry Canada (Canada)p.150H.5 Product Safety Informationp.150H.5.8.1 Safety Precautionsp.150
Page 9 of the Intel ZT 7102 user manual — Figures
Page 9 · click to enlarge
Page 9

Intel® NetStructure™ ZT 7102 Chassis Management Module

25.12.2 Data Restore User Scripts 134 25.12.3 Example Task - Replace /home/scripts/myScript with a newer version if updating for- ward or an older version if updating backward135 25.13 Update Process 136 25.14 Update Process Status and Logging 137 25.15 DEBUG_UPDATE Variable 137 25.16 Update Process Sensor and SEL Events 137 25.17 RedBoot Update Process 138 25.17.1 Required Setup 138 25.17.2 Update Procedure 138

D Example CLI Commands 139

E Datasheet Reference 141

E.1 Intel® CompactPCI* Product Information 141 E.2 CompactPCI 141 E.3 IPMI 141 E.4 Intel® IOP310 Processor Chipset 141

F Warranty Information 143

F.1 Intel® NetStructure™ Compute Boards & Platform Products Limited Warranty143 F.1.1 Returning a Defective Product (RMA) 143 F.1.2 For the Americas 143 F.1.3 For EMEA 144 F.1.4 For APAC 144

G Customer Support 147

G.2 Technical Support and Return for Service Assistance 147 G.3 Sales Assistance 147

H Agency Approvals 149

H.1 CE Certification 149 H.2 Safety 149 H.3 Emissions Test Regulations 149 H.3.5 EN 50081-1 Emissions 149 H.3.6 EN 55024 Immunity 149 H.4 Regulatory Information 150 H.4.7 FCC (USA) 150 H.4.8 Industry Canada (Canada) 150 H.5 Product Safety Information 150

Figures

1 Functional Block Diagram 14 2 System Management Architecture 18 3 Face Plate 20 4 PCB Dimensions 22 5 Connector Locations 23 6 Backplane Connectors - Pin Locations 23 7 Default Switch Configuration 31 8 Ejector Handle Operation 44

Contents

Page 10 of the Intel ZT 7102 user manual — Tables
Page 10 · click to enlarge
Page 10

Intel® NetStructure™ ZT 7102 Chassis Management Module Contents

9 BIST Flow Chart 47 10 Timing of BIST Stages 49 11 High Level SNMP/MIB Layout 97

Tables

1 Glossary 15 2 Faceplate Features 21 3 Board Dimensions and Weight 22 4 Connector Assignments 22 5 J1 Connector Pinout 24 6 J2 Connector Pinout 25 7 J3 Connector Pinout 25 8 Pin Type Definitions 26 9 Pin Descriptions 26 10 JA1 Ethernet Port Pinout 28 11 J6 Serial Port Pinout 28 12 J7 Telco Alarm Connector Pinout 29 13 CMM Power Availability 29 14 Absolute Maximum Ratings 30 15 DC Operating Characteristics 31 16 Switch Cross Reference Table 31 17 SW1-1 Functions 32 18 Battery Characteristics 35 19 CMM Synchronization 40 20 BIST Implementation 48 21 Location (-l) Keywords 57 22 Target (-t) Keywords 58 23 dataitem (-d) Keywords for All Locations 58 24 dataitem (-d) Keywords for System location 59 25 dataitem (-d) Keywords for BladeN Locations 59 26 dataitem (-d) Keywords for Chassis Location 60 27 dataitem (-d) Keywords for CMM Location 60 28 CMM Sensor Targets 68 29 Threshold-Based Sensor Event Strings (Voltage, Temp, Current, Fan) 71 30 Power Supply Event Strings (PowerSupplyN) 71 31 BIST Event Strings (BIST) 72 32 Telco Alarm Sensor Event Strings (TASensor[1,2]) 73 33 LAN Sensor Event Strings (Eth[0,1,1:1] Interface) 73 34 Fan Tray Presence Event Strings (Fan Tray [1-3] Presence) 73 35 Chassis Power Supply Event Strings (Pwr Supply N) 73 36 Slot Event Strings (Slot N Event) 74 37 CMM Redundancy Event Strings (CMM [1-2] Redundancy) 74 38 CMM Failover Event Strings (CMM Failover) 74 39 CMM File Sync Event Strings (CMM File Sync) 75 40 Chassis Sensor Event Strings 75 41 Dataitems Used With FRU Target (-t) to Obtain FRU Information 89 42 MIB II Objects - System Group 98 43 MIB II - Interface Group 98 44 SNMPv3 Security Fields 101 45 Error and Return Codes for the RPC Interface 106

Page 11 of the Intel ZT 7102 user manual — Tables
Page 11 · click to enlarge
Page 11

Intel® NetStructure™ ZT 7102 Chassis Management Module

46 Threshold Response Formats 110 47 String Response Formats 110 48 Integer Response Formats 113 49 FRU Data Items String Response Format 114 50 RPC Usage Examples 116 51 List of Critical Software Update Files and Directories 128 52 Contents of the Update Package 128 53 saveList Items and Their Priorities 130 54 Synchronization Behavior for Differing Synch Versions 132 55 Example CLI Commands 139

Contents

Page 12 of the Intel ZT 7102 user manual — Revision History
Page 12 · click to enlarge
Page 12

Intel® NetStructure™ ZT 7102 Chassis Management Module Contents

Revision History

DateRevisionDescription August 2004017Changes related to V4.11h firmware Added new BIST events for RTC and FRU checking. Added new Chassis Slot event for IPMI capable Added information on /etc/version checking Added infomation on chassis FRU validity checking. April 2004016Changes related to V4.11c firmware Added rdate feature information March 2004015Changes related to V4.11b frimware verison March 2004014Changes related to V4.11a firmware version Changes to Software Update section Slotcontrol description Changes to Heatlh Event Strings October 2003010Changes related to V4.0x firmware version New Password Reset Implementation PSInhibit Power Sequencing Policies Updated Warranty and Customer Support information. April 2003005V3.00a Release
Page 13 of the Intel ZT 7102 user manual — 1.2 ZT 7102 Features
Page 13 · click to enlarge
Page 13

1.0 Introduction

1.1 Overview

The Intel® NetStructureTM ZT 7102 is a 3U, single-slot Chassis Management Module (CMM) intended for use with PICMG* 2.1, 2.16, and 2.9-compliant systems (the CompactPCI* Hot Swap, Packet Switching Backplane, and System Management specifications, respectively). This document details the features and specifications of the ZT 7102.

The ZT 7102 plugs into a dedicated slot in compatible systems. It provides centralized management and alarming for up to 21 node and/or fabric slots as well as for system power supplies and fans. The ZT 7102 may be paired with a backup for use in high-availability applications.

The ZT 7102 is a special purpose single board computer with its own CPU, memory, PCI bus, operating system, and peripherals. The ZT 7102 monitors and configures Intelligent Platform Management Interface (IPMI)-based components in the chassis. When thresholds such as temperature and voltage are crossed or a failure occurs, the CMM captures these events, stores them in an event log, sends SNMP traps, and drives the Telco alarm relays and alarm LEDs. The CMM can query FRU information (such as serial number, model number, manufacture date, etc.), detect presence of components (such as fan tray, CPU board, etc.), and perform health monitoring of each component. In addition, the CMM controls the power-up sequencing of each node board and the power to each slot via the BD_SEL# signal.

The ZT 7102 can also be used at a limited degree to manage non-IPMI based chassis components.

1.2 ZT 7102 Features

  • High-density 3U X 1-slot form factor
  • Compatible with PICMG* 2.1, 2.16, and 2.9-compliant chassis and components
  • Monitors via the Intelligent Platform Management Bus (IPMB) protocol
  • Provides isolated IPMB signals for each slot for maximum security and reliability
  • Manage through the command line interface, SNMP v1/v3, or Remote Procedure Call (RPC)
  • Hot-add/hot-swap support for IPMI-based, field-replaceable components
  • µDB15 Telco Alarm Interface at the front panel
  • Critical, Major, and Minor alarm LEDs at the front panel
  • CMM status and hot swap LEDs at the front panel
  • Monitors backplane voltages and status for up to eight power supplies
  • Monitors system temperature sensors
  • Monitors system fan tray presence
  • Monitors tachometers for up to 16 system fans
  • Monitors sensors on PICMG 2.9 compliant single board computers
  • Power state control for single board compute blades

Introduction

Page 14 of the Intel ZT 7102 user manual — Figure 1. Functional Block Diagram
Page 14 · click to enlarge
Page 14

Intel® NetStructureTMZT 7102 Chassis Management Module Introduction

Figure 1. Functional Block Diagram

Intel ZT 7102 — Figure 1. Functional Block Diagram diagram (page 14)
Fig. 1 · Figure 1. Functional Block Diagram

(7 3 8 9 , 3 9 : ,, 3

(& ! 3 .%3 4 ) 3+

; / ! !* - !* - * , , 6 :

Page 15 of the Intel ZT 7102 user manual — Table 1. Glossary
Page 15 · click to enlarge
Page 15

1.3 Terms Used in This Document

Table 1. Glossary

CMM Chassis Management Module

CLI Command Line Interface

FRU Field Replaceable Unit

IPMI Intelligent Platform Management Interface

IPMB Intelligent Platform Management Bus

MIB Management Information Base

MIB II RFC1213 - A standard Management Information Base for Network Management

SEL System Event Log

SBC Single Board Computer

SNMP Simple Network Management Protocol

SNMP v.1 SNMP version 1

SNMP v.3 SNMP version 3

SDR Sensor Data Record

Introduction · Acronym Description

Page 16 of the Intel ZT 7102 user manual — 1.3 Terms Used in This Document
Page 16 · click to enlarge
Page 16

Intel® NetStructureTMZT 7102 Chassis Management Module Introduction

Page 17 of the Intel ZT 7102 user manual — 2.1 Overview
Page 17 · click to enlarge
Page 17

2.0 Hardware Specifications

2.1 Overview

The chassis management module (CMM) is intended to operate as a chassis management building block in a CompactPCI chassis. The CMM uses a unique backplane interface pinout and requires a dedicated slot within the chassis.

Intelligent Platform Management Buses (IPMBs) are the primary management connection between components. A unique star topology radiating from the CMMs is used to provide reliability, flexibility and security. In some cases, direct logic is used to support non-intelligent devices and to eliminate active components on the backplane and chassis.

The CMM provides 30 master/slave two-wire serial bus (2WSB) interfaces. The 2WSBs are electrically equivalent to I2C*. As such, all outputs are open drain, so they are driven low and passively pulled high. The 2WSB interfaces support multi-master operation on the bus, however they do not support being the target of a read transaction from another master device. The 2WSB interfaces are used by the CMM as IPMBs or non-intelligent management busses. Refer to the individual sections for specific usage information. The 2WSB interfaces are used for:

  • Up to 21 general-purpose slots (21 independent 2WSBs, 2WSB_S0 - 2SB_S20)
  • Power supplies (two buses, 2WSB_PS0 and 2WSB_PS1)
  • Fan trays (one bus, 2WSB_FT)
  • Chassis sensors (one bus, 2WSB_CS)
  • Chassis FRU modules (two independent buses, 2WSB_CF0 and 2WSB_CF1)
  • Redundant CMM link (one bus for bi-directional communication, 2WSB_RCMM)

Hardware Specifications

Page 18 of the Intel ZT 7102 user manual — 2.3 Backplane Connections
Page 18 · click to enlarge
Page 18

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.2 System Architecture

Figure 2. System Management Architecture

Intel ZT 7102 — Figure 2. System Management Architecture diagram (page 18)
Fig. 2 · Figure 2. System Management Architecture

2.3 Backplane Connections

2.3.1 Slot Connections

The slots are connected to the CMM via an IPMB defined in the PICMG* 2.9 specification. The CMM also has connections for BD_SEL# and HEALTHY# signals to each slot. Each slot has an independent IPMB, BD_SEL#, and HEALTHY#. The CMM supports up to 21 general-purpose node slots.

The IPMB is used for IPMI management communication between the CMM and the board in the slot. Each board that is to be managed by the CMM is required to support the IPMB as a management channel.

BD_SEL# is used in CompactPCI slots to control board power and to detect board presence. The CMM provides a bi-directional open drain driver for each BD_SEL#. The board installed in the slot provides a pull-up resistor (1.2 KΩ ± 5% per PICMG* 2.0). The CMM provides a weak pulldown resistor (and a diode clamp). When not asserted, BD_SEL# can be read to determine if a board is present in the slot. If BD_SEL# is high, a board is present. If BD_SEL# is not asserted a board is not present. Asserting BD_SEL# allows the board to power up.

HEALTHY# is an input to the CMM. The CMM provides a pull-up resistor. The board in the slot asserts HEALTHY# based on board power being good and optionally other board-specific requirements. BD_SEL# must be asserted for HEALTHY# to be asserted. When BD_SEL# is asserted, and a board is removed, HEALTHY# will be deasserted.

Page 19 of the Intel ZT 7102 user manual — 2.5 Fan Modules
Page 19 · click to enlarge
Page 19

2.3.2 Chassis Sensor Connections

Chassis sensors are connected to the CMM via one two-wire serial bus.

2.3.3 Chassis FRU Device Connections

Chassis sensors are connected to the CMM via one two-wire serial bus. The CMM provides two 2WSB interfaces for chassis FRU modules. Each chassis FRU module is on a dedicated 2WSB in order to provide redundant access to vital chassis information (e.g., the physical location of the chassis). The backplane FRU storage device used MUST be an Atmel* AT24C16 or other 24C16-compatible device.

2.3.4 Redundancy

The CMM supports redundant operation with automatic failover under hardware or software control. The following hardware interfaces exist for the support of redundancy and automatic failover:

  • Cross-connected CMM present inputs (PRES_I#) and outputs (PRES_O#)
  • Cross-connected CMM healthy inputs (HLY_I#) and outputs (HLY_O#)
  • Cross-connected negotiation inputs (NEG_I) and outputs (NEG_O)

The active CMM monitors its PRES_I# and HLY_I# inputs to determine if it has a healthy, standby CMM. The active CMM deasserts its HLY_O# output to trigger a failover to the standby CMM.

The cross-connected negotiation signals are used to assure that only one CMM is active at a time. At anytime, the standby CMM can trigger a failover by driving its NEG_O output low.

2.4 Power Modules

Power supply sleds are connected to the CMM via two IPMBs. Each power supply sled connects to one IPMB. Multiple power supplies can share a single IPMB. The CMM also provides independent DEG#, FAIL#, and INH# signals as defined in PICMG* 2.11 for up to eight power supplies. The CMM will communicate with intelligent supplies via the IPMBs. Non-intelligent supplies are supported via the DEG# (degrade), FAIL# (fail), and INH# (inhibit) signals.

The CMM uses INH# rather than EN# to control the power supplies. The EN# pin is grounded on the backplane to signal to a power supply when it is fully seated in its connector.

2.5 Fan Modules

Fan trays are connected to the CMM via one two-wire serial bus (2WSB). Intelligent fan trays communicate with the CMM via the IPMB. To support non-intelligent fan trays, the CMM also provides independent fan tachometer inputs for up to 16 fans, fan tray present inputs for up to four fan trays, and four fan speed outputs (four buffered copies of a single PWM). Non-intelligent fan trays are monitored and controlled via the fan tachometer inputs and the fan speed output.

Hardware Specifications

Page 20 of the Intel ZT 7102 user manual — Figure 3. Face Plate
Page 20 · click to enlarge
Page 20

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.6 Face Plate

Figure 3. Face Plate

Intel ZT 7102 — Figure 3. Face Plate diagram (page 20)
Fig. 3 · Figure 3. Face Plate
Page 21 of the Intel ZT 7102 user manual — Table 2. Faceplate Features
Page 21 · click to enlarge
Page 21

2.6.1 Faceplate Features

The following features are found on the faceplate of the ZT 7102:

Table 2. Faceplate Features

These LEDs indicate the presence of various event-triggered alarms. The LEDs function as follows:

Minor, Major, and Critical Alarm LEDs

Off = no alarm triggered.

Amber = alarm triggered.

Blinking = alarm cutoff (ACO) is activated.

This push button toggles the ACO state. When ACO is activated, the active alarm LEDs blink and all of the alarm relays are deactivated. This button does not clear alarms.

Alarm Cutoff (ACO) push button

The ZT 7102 can be reset by pressing and holding the ACO button for about five seconds.

Telco Alarm Interface (µDB15 connector)

This interface relays alarm signals to off-board equipment. Contact Intel for a compatible cable (µDB15 to standard DB15). See Appendix G, “Customer Support.” for details.

COM Port (RJ-45 connector) This serial port may be used to access the CMM's Command Line Interface (CLI).

This port provides an out-of-band 10/100 Ethernet connection. The port's integrated LEDs function as follows:

YellowOff = 10 Mbit On = 100 Mbit

Ethernet Port (RJ-45 with LEDs)

GreenOff = No Link On = Link Blinking = Activity

This LED indicates CMM status as follows:

Green = power is on and the board is acting as the master (active) CMM.

Blinking green = power is on and the board is acting as the backup (standby) CMM.

Red = the CMM needs attention (a critical problem exists).

This LED indicates when it is safe to remove the CMM from a live (powered-on) chassis. The LED functions as follows:

Off = the CMM is not ready to be removed from a live chassis.

Blue = the CMM is ready to be removed from a live chassis.

The ejector functions as a handle and a lever for installing or removing the CMM. The ejector incorporates a switch that tells the CMM when the board is about to be removed from a system.

Ejector with hot swap switch

Show 4 more labels / short text on this page
Hardware Specifications · Feature Purpose · CMM Status LED · Hot Swap LED
Page 22 of the Intel ZT 7102 user manual — Table 4. Connector Assignments
Page 22 · click to enlarge
Page 22

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.7 Mechanical

2.7.1 Board Dimensions and Weight

In a compatible enclosure, the ZT 7102 occupies a single 3U CMM slot. Mechanical dimensions are shown in Figure 4 and outlined in Table 3.

Table 3. Board Dimensions and Weight

PCB Dimensions100 mm x 160 mm x 1.6 mm
Board Dimensions3U x 4HP (one slot)
Weight7.7 ounces w/ 128 Mbyte SODIMM

2.7.2 PCB Dimensions

Figure 4. PCB Dimensions

Intel ZT 7102 — Figure 4. PCB Dimensions diagram (page 22)
Fig. 4 · Figure 4. PCB Dimensions

2.8 Connectors

As shown in Figure 5, the ZT 7102 includes several connectors to interface to application-specific devices. A brief description of each connector is given in Table 4 below. A detailed description and pinout for the backplane connectors is given in the following sections.

Table 4. Connector Assignments

J1, Table 5 Backplane Connector (110-pin, 2 mm x 2 mm, female)

J2, Table 6 Backplane Connector (55-pin, 2 mm x 2 mm, female)

J3, Table 7 Backplane Connector (55-pin, 2 mm x 2 mm, female)

J4 Connector reserved for test.

JA1, Table 10 Ethernet Connector (RJ-45, 8-pin)

J6, Table 11 Serial Port (RJ-45, 8-pin)

Connector Function

Page 23 of the Intel ZT 7102 user manual — Figure 6. Backplane Connectors - Pin Locations
Page 23 · click to enlarge
Page 23

Table 4. Connector Assignments

J7, Table 12 Telco Alarm Connector (uDB-15, 15-pin)

J8, SODIMM Socket (144-pin)

J9 Connector reserved for test.

Figure 5. Connector Locations

Intel ZT 7102 — Figure 5. Connector Locations diagram (page 23)
Fig. 5 · Figure 5. Connector Locations

Figure 6. Backplane Connectors - Pin Locations

Intel ZT 7102 — Figure 6. Backplane Connectors - Pin Locations diagram (page 23)
Fig. 6 · Figure 6. Backplane Connectors - Pin Locations

Hardware Specifications · Connector Function

Page 24 of the Intel ZT 7102 user manual — 2.8.2 J2 Backplane Connector
Page 24 · click to enlarge
Page 24

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.8.1 J1 Backplane Connector

J1 is a 110-contact, 2 mm x 2 mm female CompactPCI form-factor connector (AMP 352152-1). See Table 5 for pin definitions and Figure 6, “Backplane Connectors - Pin Locations” on page 23 for relative pin placement.

Table 5. J1 Connector Pinout

Pin# A B C D E F

22 PDEG0# PDEG2# GND PDEG4# PDEG6#

21 PDEG1# PDEG3# IPMB_PWR PDEG5# PDEG7#

20 PFAIL0# PFAIL2# GND PFAIL4# PFAIL6#

19 PFAIL1# PFAIL3# IPMB_PWR PFAIL5# PFAIL7#

18 PINH0# PINH2# GND PINH4# PINH6#

17 PINH1# PINH3# IPMB_PWR PINH5# PINH7#

16 PS_SCL0 PS_SDA0 GND PRES_I# GA0

15 PS_SCL1 PS_SDA1 RES FANP0# FANP2#

14 FT_SCL FT_SDA GND FANP1# FANP3#

13 CS_SCL CS_SDA RES FANPWM0 FANPWM2

12 CF_SCL0 CF_SDA0 GND FANPWM1 FANPWM3

GROUND

SHIELD

11 CF_SCL1 CF_SDA1 RES FANTK0 FANTK8

10 RES RES GND FANTK1 FANTK9

9 RES RES RES FANTK2 FANTK10

8 STx SRx SRI FANTK3 FANTK11

7 SCTS SRTS SCD FANTK4 FANTK12

6 SDSR SDTR RES FANTK5 FANTK13

5 RPMAC# RPMIC# RES FANTK6 FANTK14

4 RPCR# RPMAR# RPMIR# FANTK7 FANTK15

3 BP_5V BP_N12V BP_12V BP_3.3V VIO

2 SwTx+ SwTx- GND RpTx+ RpTx-

1 SwRx+ SwRx- GND RpRx+ RpRx-

2.8.2 J2 Backplane Connector

J2 is a 55-contact, 2 mm x 2 mm female CompactPCI* form-factor connector (AMP* 352115-1). See Table 6 for pin definitions and Figure 6 for relative pin placement.

Page 25 of the Intel ZT 7102 user manual — 11 N_HLY1# N_BDS1# N_HLY10# N_BDS10# N_HLY18#
Page 25 · click to enlarge
Page 25

Table 6. J2 Connector Pinout

Pin# A B C D E F

11 N_SCL1 N_SDA1 N_SCL10 N_SDA10 N_SCL18

10 N_SCL2 N_SDA2 N_SCL11 N_SDA11 N_SDA18

9 N_SCL3 N_SDA3 N_SCL12 N_SDA12 N_SCL19

8 N_SCL4 N_SDA4 N_SCL13 N_SDA13 N_SDA19

7 N_SCL5 N_SDA5 N_SCL14 N_SDA14 N_SCL20

6 N_SCL6 N_SDA6 N_SCL15 N_SDA15 N_SDA20

GROUND

SHIELD

5 N_SCL7 N_SDA7 N_SCL16 N_SDA16 N_SCL21

4 N_SCL8 N_SDA8 N_SCL17 N_SDA17 N_SDA21

3 N_SCL9 N_SDA9 GND NEG_O HLY_O#

2 R_SCL IPMB_PWR RES IPMB_PWR HLY_I#

1 GND R_SDA CMM_SEL# NEG_I GND

All signals interface to medium length pins on the backplane except as noted.

= Interfaces to long connector pins on the backplane. = Interfaces to short connector pins on the backplane.

2.8.3 J3 Backplane Connector

J3 is a 55-contact 2 mm x 2 mm female CompactPCI form-factor connector (AMP 352115-1). See Table 7 for pin definitions and Figure 6 for relative pin placement.

Table 7. J3 Connector Pinout

Pin# A B C D E F

11 N_HLY1# N_BDS1# N_HLY10# N_BDS10# N_HLY18#

10 N_HLY2# N_BDS2# N_HLY11# N_BDS11# N_BDS18#

9 N_HLY3# N_BDS3# N_HLY12# N_BDS12# N_HLY19#

8 N_HLY4# N_BDS4# N_HLY13# N_BDS13# N_BDS19#

7 N_HLY5# N_BDS5# N_HLY14# N_BDS14# N_HLY20#

GROUND

6 N_HLY6# N_BDS6# N_HLY15# N_BDS15# N_BDS20#

SHIELD

5 N_HLY7# N_BDS7# N_HLY16# N_BDS16# N_HLY21#

4 N_HLY8# N_BDS8# N_HLY17# N_BDS17# N_BDS21#

3 N_HLY9# N_BDS9# IPMB_PWR PIMP0# RES

2 RES GND RES GND RES

1 IPMB_PWR RES PRES_O# PIMP1# IPMB_PWR

All signals interface to medium length pins on the backplane except as noted.

= Interfaces to long connector pins on the backplane. = Interfaces to short connector pins on the backplane.

Hardware Specifications

Page 26 of the Intel ZT 7102 user manual — I/O
Page 26 · click to enlarge
Page 26

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.8.4 Backplane Pin Descriptions

Table 8. Pin Type Definitions

Table 9. Pin Descriptions (Sheet 1 of 2)

Name Count Type Description

N_SCL[1..21] 21 OD Node IPMI clock

N_SDA[1..21] 21 OD Node IMPI data

PS_SCL[0..1] 2 OD Power Supply Chassis IMPI clock

PS_SDA[0..1] 2 OD Power Supply Chassis IMPI data

FT_SCL 1 OD Fan Tray Chassis IMPI clock

FT_SDA 1 OD Fan Tray Chassis IMPI data

CS_SCL 1 OD Chassis Sensor IMPI clock

CS_SDA 1 OD Chassis Sensor IMPI data

CF_SCL[0..1] 2 OD Chassis FRU IMPI clock

CF_SDA[0..1] 2 OD Chassis FRU IMPI data

R_SCL 1 OD Redundant CMM serial clock

R_SDA 1 OD Redundant CMM serial data

N_HLY#[1..21] 21 I Node Healthy (0 = Node is healthy)

N_BDS#[1..21] 21 OD

Node Board Select (5 V = Node is present, drive to 0 to turn node on)

I/O

SwTx(+/-) 2 I/O 10/100 Ethernet To Switch

SwRx(+/-) 2 I/O 10/100 Ethernet From Switch

FANTK[0..15] 16 I Fan Tach Inputs

FANPWM[0..3] 4 O Fan Speed Control (3.3 V = ON)

FANP#[0..3] 4 I Fan tray present (3.3 V = fan tray is missing)

PDEG#[0..7] 8 I Power supply degrade

PFAIL#[0..7] 8 I Power supply fail

PINH#[0..7] 8 O Power supply inhibit

STx 1 O Serial transmit

SRx 1 I Serial receive

SCTS 1 I Serial clear to send

SRTS 1 O Serial request to send

SDSR 1 I Serial data set ready

Show 5 more labels / short text on this page
Pin Type Definition · OD Open Drain · I Input · I/O Input/Output · O Output
Page 27 of the Intel ZT 7102 user manual — TOTAL 220
Page 27 · click to enlarge
Page 27

Table 9. Pin Descriptions (Sheet 2 of 2)

Name Count Type Description

SDTR 1 O Serial data terminal ready

SRI 1 I Serial ring indicator

SCD 1 I Serial carrier detect

RpTx(+-) 2 I/O 10/100 Ethernet To rear panel

RpRx(+-) 2 I/O 10/100 Ethernet From rear panel

NEG_O 1 O Negotiate output to other CMM

NEG_I 1 I Negotiate input from other CMM

HLY_O# 1 O Healthy output to other CMM

HLY_I# 1 I Healthy input from other CMM

PRES_I# 1 I Other CMM is present (0V)

PRES_O# 1 O Grounded on CMM.

GA0 1 I Location Address

CMM_SEL# 1 I Tells CMM it has been seated. (Backplane grounds this pin)

GND 14 I CMM GND

IPMB_PWR 8 I CMM Power

BP_12V, BP_N12V,

4 I Monitor backplane power 12,-12,5,3.3

BP_3.3V

RPMAC# 1 I Rear panel major alarm clear

RPMIC# 1 I Rear panel minor alarm clear

RPCR# 1 O Rear panel critical alarm relay

RPMAR# 1 O Rear panel major alarm relay

RPMIR# 1 O Rear panel minor alarm relay

VIO 1 I Backplane IO voltage (may not be present in non-PCI system)

RES 18 NC No Connect on Backplane

TOTAL 220

2.8.5 JA1 Ethernet Port

JA1 is an RJ-45 Ethernet port providing 10 Mbit (10BASE-T) and 100 Mbit (100BASE-TX) protocols. JA1 connects to the CMM's LAN0 Ethernet channel. A second Ethernet channel, LAN1, is only available at the backplane.

Two LEDs are located in the RJ-45 Ethernet connector:

  • Yellow indicates speed
  • Green indicates a link/activity

See Table 10 for JA1 Ethernet port pin definitions.

Hardware Specifications · BP_5V, and

Page 28 of the Intel ZT 7102 user manual — 2.8.7 J7 Telco Alarm Connector
Page 28 · click to enlarge
Page 28

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

Table 10. JA1 Ethernet Port Pinout

1 TX+

2 TX-

3 RX+

4,5 Unused pair; terminated on ZT 7102

6 RX-

7 Unused pair; terminated on ZT 7102

2.8.6 J6 Serial Port

J6 is an RJ-45 connector providing a front-panel RS-232 serial port interface. Serial port signals are also directed out connector J1 to the backplane. See Table 11 for J6 serial port pin definitions.

Table 11. J6 Serial Port Pinout

1 SRTS Serial Request To Send

2 SDTR Serial Data Terminal Ready

3 STx Serial Transmit

6 SRx Serial Receive

7 SDSR Serial Data Set Ready

8 SCTS Serial Clear to Send

- SRI Serial Ring Indicator (not utilized)

- SCD Serial Carrier Detect (not utilized)

2.8.7 J7 Telco Alarm Connector

J7 is a µDB-15 connector providing a front-panel telco alarm interface. See Table 12 for J7 Telco alarm connector pin definitions. Contact Intel for information about obtaining a compatible µDB-15 to DB-15 cable. Contact information is located in Appendix G, “Customer Support”.

For additional information on the Telco Alarm Connector, refer to the Wiring Telco Alarm Connectors Application Note posted at the following location:

http://www.intel.com/design/network/applnots/273926.htm

Show 4 more labels / short text on this page
Pin # Description · Pin# Function Description · 4 GND Ground · 5 GND Ground
Page 29 of the Intel ZT 7102 user manual — Table 13. CMM Power Availability
Page 29 · click to enlarge
Page 29

Table 12. J7 Telco Alarm Connector Pinout

Pin # Function Description

1 AMIR+ MinorReset +

3 AMAR+ MajorReset +

5 ACNO CriticalAlarm - NO

6 ACNC CriticalAlarm - NC

7 ACCOM CriticalAlarm - COM

8 AMINO MinorAlarm - NO

9 AMINC MinorAlarm - NC

10 AMINCOM MinorAlarm - COM

11 AMANO MajorAlarm - NO

12 AMANC MajorAlarm - NC

13 AMACOM MajorAlarm - COM

14 APRCO PwrAlarm - NO

15 APRCOM PwrAlarm - COM

- GND Not Utilized

COM=Common NO=Normally Open NC=Normally Closed

2.9 Electrical and Environmental

The ZT 7102 requires +5 VDC ±5% @ 1.8 A typical. CMM power comes from the backplane's IPMI_PWR rail; other voltages are derived as needed.

2.9.1 CMM Power

CMM power comes from the backplane’s 5 V power (IPMI_PWR). See Table 13 for available voltages.

Table 13. CMM Power Availability

Voltage Maximum Current Where Used

5 100 mA Miscellaneous components that cannot use 3.3 V.

3.3 4 A 80312 and most logic

2.5 700 mA FPGA core

1.5 500 mA 80200 core

Hardware Specifications · 2 AMIR- MinorReset - · 4 AMAR- MajorReset -

Page 30 of the Intel ZT 7102 user manual — Table 14. Absolute Maximum Ratings
Page 30 · click to enlarge
Page 30

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.9.2 Power Ramp Circuitry

The ZT 7102 features a power controller with power ramp circuitry to allow the board’s voltages to be ramped in a controlled fashion. The power ramp circuitry eliminates large voltage or current spikes caused by hot swapping boards. Controlled voltage ramping is a requirement of the CompactPCI* Hot Swap Specification, PICMG* 2.1, Version 2.0.

Fault current sensing is also provided. When a board fault (short circuit) or overcurrent condition is detected, the hot swap controller automatically removes power from the CMM components, and the Status LED on the faceplate illuminates red (see Table 3, “Face Plate” on page 20). Fault protection activates when the current exceeds 10 A for longer than 10 ms.

2.9.3 Operating Temperature

The ZT 7102 processor can operate between +5° C and approximately +65° C ambient. It is the users' responsibility to ensure that the ZT 7102 is installed in a chassis capable of supplying adequate airflow. The maximum power dissipation of the processor is 15 W (10 W typical). External airflow must be provided at all times.

2.9.4 Reliability

MTBF479,000 hours at 40° Celsius
MTTRThree minutes (based on hot-swap board replacement), plus system startup

2.9.5 Absolute Maximum Ratings

See Table 14 for absolute maximum ratings.

Table 14. Absolute Maximum Ratings

Signal or Characteristic Range

Supply Voltage, VCC 5 V ±5% with 50 mV maximum ripple

Storage Temperature -40° to +85° Celsius

Operating Temperature +5° to +65° Celsius

Non-Condensing Relative Humidity

Page 31 of the Intel ZT 7102 user manual — Figure 7. Default Switch Configuration
Page 31 · click to enlarge
Page 31

2.9.6 DC Operating Characteristics

Table 15. DC Operating Characteristics

Supply Voltage, VCC 4.85 V minimum to 5.25 V maximum

1.8 A average (with 733 MHz processor and 32 Mbyte of SDRAM. Peak (short duration) power supply current may be significantly higher (up to 50%) and varies depending upon the application.

Supply Current, ICC

2.10 Onboard Switches

The ZT 7102 contains a push-button switch on the faceplate and one bank of DIP switches on the component side of the board. See Table 16 for switch identification and functions. Factory default switch settings are shown in Figure 7.

Table 16. Switch Cross Reference Table

S1, “S1 (Alarm Cutoff and Board Reset)” on page 32 Alarm Cutoff and Board Reset

SW1-1, “SW1-1 (Password Reset)” on page 32 Reset Password

See Figure 7 for the default switch configuration.

Figure 7. Default Switch Configuration

Intel ZT 7102 — Figure 7. Default Switch Configuration diagram (page 31)
Fig. 7 · Figure 7. Default Switch Configuration
Show 6 more labels / short text on this page
Hardware Specifications · Signal Range · Switch Function · SW1-2 Reserved · SW1-3 Reserved · SW1-4 Reserved
Page 32 of the Intel ZT 7102 user manual — 2.11 Processor and Chipset
Page 32 · click to enlarge
Page 32

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.10.1 Switch Descriptions

The following topics provide a detailed description of each switch.

2.10.1.1 S1 (Alarm Cutoff and Board Reset)

S1 is a push button at the faceplate of the ZT 7102. S1 toggles the CMM's alarm cutoff (ACO) state. When ACO is activated, the active alarm LEDs blink and the alarm relays are deactivated. This button does not clear alarms.

The Alarm Cutoff feature automatically cancels itself under the following conditions:

  • When the ACO is engaged for more than 10 minutes without an active alarm present. This prevents the ACO from being accidentally left engaged after an alarm is cleared).
  • When the ACO is engaged for more than x minutes, even if an active alarm is present (x can be set in the Command Line Interface with the Data item keyword AlarmTimeOut, see Table 23, “dataitem (-d) Keywords for All Locations” on page 58 ).

In addition to its ACO function, S1 is used to reset the CMM by pressing and holding the button for about five seconds. Reset is discussed in more detail in Section 4.0, “CMM Redundancy, Synchronization and Failover” on page 39.

2.10.1.2 SW1-1 (Password Reset)

Closing this switch resets the CMM's root logon password. Use this feature if you forget your password or want to restore the default root password for other reasons. For more information about resetting to the default root password, refer to Section 9.0, “Resetting the Password” on page 63.

Table 17. SW1-1 Functions

Open [default] Does not reset the CMM's root password at reboot.

Closed Resets the CMM's root password at reboot.

2.11 Processor and Chipset

The Intel® IOP310 chipset contains two devices, the Intel® 80200 processor and the Intel® 80312 I/O companion chip. The 733 MHz 80200 processor features 32 Kbit data and instruction caches. The 80312 companion chip provides a memory controller and a PCI interface for the CMM's Ethernet controllers. Appendix E, “Datasheet Reference” contains a link to the datasheet for the chipset.

The ZT 7102 uses the Intel® IOP310 I/O processor chipset. Based on Intel XScale® microarchitecture, this chipset combines high performance processing with ultra-low power consumption.

SW1-1 Function

Page 33 of the Intel ZT 7102 user manual — 2.15 Serial I/O
Page 33 · click to enlarge
Page 33

2.12 Memory

The ZT 7102 includes 128 Mbytes of SDRAM on a Small Outline Dual Inline Memory Module (SODIMM). The SODIMM used is 16 Mbits x 72 PC133 unbuffered SDRAM with ECC on a 144-pin module.

2.12.1 Removing the SODIMM

The following instructions cover the mechanical aspects of removing the SODIMM from a ZT 7102.

1. Take the necessary precautions to protect the ZT 7102 and the SODIMM from static discharge.
2. Locate the SODIMM socket. Refer to Table 4, “Connector Assignments” on page 22 for the socket's location.
3. Press outward on the clips at either end of the SODIMM socket (press both clips at the same time) until the module ejects from the slot and tilts upward.
4. Pull the SODIMM away from the socket.

2.12.2 Installing Memory

The following instructions cover the mechanical aspects of installing the SODIMM in a ZT 7102.

1. Take the necessary precautions to protect the ZT 7102 and the SODIMM from static discharge.
2. Hold the SODIMM at an angle and push it into the SODIMM socket. Refer to Table 4, “Connector Assignments” on page 22 for the socket's location.
3. Align the notches on the ends of the module with the matching bumps on the latches and gently push the module down until it clicks in place.

2.13 Flash

The ZT 7102 uses an on-board 64 Mbyte flash memory device.

2.14 Dual Ethernet Controllers

The ZT 7102 uses two Intel® 82559 Fast Ethernet Controllers. The 82559 consists of both the Media Access Controller (MAC) and the physical layer (PHY) interface combined into a single component solution.

The CMM provides an RJ-45 connector on the faceplate to connect to out-of-band 10/100 LAN0. This connector is labeled with the Ethernet icon (refer to “Face Plate” on page 20). Care should be taken not to confuse the RJ-45 Ethernet port with the RJ-45 serial port that is next to it. (Note that the Ethernet port has integrated speed and activity LEDs).

2.15 Serial I/O

The ZT 7102 provides an RS-232 compatible RJ-45 serial port connector on the faceplate. Serial port signals are also available for rear panel access.

Hardware Specifications

Page 34 of the Intel ZT 7102 user manual — 2.18 Network Time Synchronization
Page 34 · click to enlarge
Page 34

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.16 Telco Alarm Signal

2.16.1 Alarm Relays

The ZT 7102’s alarm relay circuits are capable of carrying 60 VDC or 1 A, with a maximum rating of 30 VAC.

2.16.2 Opto Inputs

The ZT 7102 accepts timed pulse inputs for clearing Minor and Major alarm states (there is no reset for the Critical state). Reset is accomplished by asserting a voltage differential from 3.3 V to 48 V for between 200 and 300 ms. The acceptable voltage range is from 0 to 48 VDC continuous (handles up to 60 VDC at a 50 percent duty cycle). The current drawn by a reset input should not exceed 12 mA.

2.17 Real Time Clock

A Dallas Semiconductor* DS1307 Serial Real-Time Clock allows the ZT 7102 to keep track of time for accurate event logging. The DS1307 features 56 bytes of nonvolatile SRAM, a 100-year calendar, and battery backup.

The Real-Time Clock keeps time in UTC only. If the time is set for a different time zone, as in the example below, the difference will be automatically calculated giving the UTC equivalent. In this example, the time will be set 8 hours ahead of the local time.

To set the real-time clock, enter the correct date and time in the following format:

setdate 'Thu Apr 01 09:04:29 PST 2004'

The above command would set the time and date to the following:

Thu Apr 1 17:04:29 UTC 2004

2.18 Network Time Synchronization

The CMM supports the RFC 868 Time Protocol. This allows the CMM to be configured to retrieve the date and time from a server over a TCP/IP network using the rdate command. To properly configure time synchronization using the RFC 868 Time Protocol, follow the steps below.

Enable RFC 868 Time Protocol on a Linux/Unix Host (server):

  • In general this depends upon the OS and version. Please consult your OS documentation.
  • The easiest way to enable this service is to use the OS GUI to enable the "time" server. This is part of inetd/xinetd.
Page 35 of the Intel ZT 7102 user manual — Table 18. Battery Characteristics
Page 35 · click to enlarge
Page 35

Enable RFC 868 Time Protocol on CMM (client):

1. Create file "/etc/rdate.cfg".
2. Edit file "/etc/rdate.cfg" with a valid host name or IP address of an enabled RFC 868 Time Protocol server.
3. Reboot the CMM, and check the new date (use "date") to make sure it is identical to the RFC 868 Time Protocol server (use "busybox rdate -p ".
4. This file will only be preserved during upgrades to same or newer versions.

Note: Since rdate is executed during CMM boot, it is possible that on a chassis powerup the CMM may not be able to sync up with a server if the network path to it is through the backplane Ethernet port. For proper network time synchronization during CMM boot, the CMM should be able to contact the time server through the front Ethernet port.

2.19 Watchdog Timer

The ZT 7102 uses a Maxim* MAX6374KA-T watchdog timer to supervise processor activity. When the software fails to strobe the watchdog within a set period (once every second), the watchdog alerts the CMM's Complex Programmable Logic Device (CPLD), which resets the CPU.

2.20 Battery Backup

The CMM contains a CR 1025 onboard battery to retain certain functions such as the real time clock, even when no standby power to the board is present. If it becomes apparent that the time and date no longer stay current, then the battery should be replaced. The battery should only be replaced with a lithium CR 1025 or equivalent. After the battery is replaced, use the setdate command to set the time correctly. See Section 2.17, “Real Time Clock” on page 34 for information on setting the time and date.

2.20.1 Replacing the Battery

1. Slide the battery out from the battery retention clip.
2. Slide the new battery into the clip with the positive (+) side up. The metal arm of the retention clip should rest on top of the positive side of the battery.

Table 18. Battery Characteristics

Battery Voltage3 V
Battery Capacity30 mAh
Real-Time Clock Requirements300 uA typical, 500 uA maximum (Vbat = 3 V, Vcc = 0 V)

Real-Time Clock Data Retention: 11.4 years typical/6.8 years minimum (not powered). When powered, RTC takes its power from +5v, not battery.

Electrochemical Construction: Long-life lithium with solid-state polycarbon monofluoride cathode.

Hardware Specifications · Characteristic Description

Page 36 of the Intel ZT 7102 user manual — 2.21 Running Your System Without A CMM
Page 36 · click to enlarge
Page 36

Intel® NetStructureTMZT 7102 Chassis Management Module Hardware Specifications

2.21 Running Your System Without A CMM

In CMM-based systems, the CMM controls power to the general-purpose slots in accordance with the PICMG* 2.1 specification. PICMG* 2.1 defines the power control signals (BD_SEL#) as pulled up on general-purpose boards. When the BD_SEL# signals are not asserted (grounded) by external means, the general-purpose boards will not power up. Therefore, to operate a CMM-based system without a CMM board, BD_SEL# must be grounded at each slot on the backplane.

Your system may have jumpers at each slot on the backplane to ground BD_SEL#. Inserting the BD_SEL# jumper will allow the node slot to power up regardless of the CMM. Node slots with the BD_SEL# jumper installed cannot be managed using the CMM. Refer to system-specific documentation for more information about running the system with or without a CMM board.

Page 37 of the Intel ZT 7102 user manual — 3.5 Ethernet Interfaces
Page 37 · click to enlarge
Page 37

3.0 Software Specifications

3.1 Operating System

The CMM runs a customized version of embedded BlueCat* Linux* 4.0 on an Intel® 80200 processor with Intel XScale® technology. Development support for BlueCat Linux* is available on the web at http://www.lynuxworks.com

3.2 Command Line Interface (CLI)

The Command Line Interface (CLI) connects to and communicates with the intelligent management devices of the chassis, boards and the CMM itself. The CLI is an IPMI-based library of commands that can be accessed directly or through a higher-level management application. Administrators can access the CLI through Telnet or the CMM's serial port. Using the CLI, users can access information about the current state of the system including current sensor values, threshold settings, recent events, and overall chassis health.

3.3 SNMP/UDP

The chassis management module supports both queries and traps on SNMP v1 or v3. The SNMP version can be configured through the CLI interface. The default is for SNMP v1. A MIB for the entire platform is included with the CMM.

Along with SNMP traps, the CMM sends UDP alerts to port 10000. The content of these UDP alerts is the same as the SNMP traps.

3.4 Remote Procedure Call (RPC) Interface

In addition to the console command-line interface, the CMM can be administered by custom remote applications via remote procedure calls (RPC).

3.5 Ethernet Interfaces

Eth1 is the Ethernet port going to the backplane on the CMM. Eth1 should remain static at all times. It is through this port that synchronization will be attempted initially. For synchronization to occur on eth1, both Ethernet switches must be present in the chassis.

Eth1:1 is a an IP address used to connect to the active CMM at any time through the chassis backplane and therefore should remain static. Eth1:1 is a static alias of eth1 defined in the /etc/ifcfg-eth1 file as STATICIP2. Because this IP address is synced between the two CMMs, it should only be changed on the active CMM. See Section 7.3.1, “Setting IP Address Properties” on page 54 on how to set the eth1:1 IP address.

Eth0 is the Ethernet interface on the front of the CMM that can connect to an external or private management network through a switch or through a crossover to the other CMM. This is used if no Ethernet switches are available in the chassis. Eth0 can be set to static or DHCP.

Software Specifications

Page 38 of the Intel ZT 7102 user manual — 3.6.4 Retrieving a SEL
Page 38 · click to enlarge
Page 38

Intel® NetStructureTMZT 7102 Chassis Management Module Software Specifications

In a platform containing redundant CMMs, upon initial power up, both CMMs will have identical IP addresses on all of their Ethernet interfaces. The standby CMM will automatically decrement its IP address on Eth1 by 1 so that synchronization can occur; however, the user must change these IP addresses upon initial login so that an address conflict does NOT occur and synchronization and failover can operate correctly. See Section 7.3.1, “Setting IP Address Properties” on page 54 for further information and instructions on changing the IP addresses. See Section 4.0, “CMM Redundancy, Synchronization and Failover” on page 39 for further information regarding synchronization, failover, and redundancy.

3.6 Sensor Event Logs (SEL)

The chassis management module utilizes a dual domain for hosting the sensor event logs (SEL) of the chassis components and boards used in the platform. With the dual domain architecture, some SEL files are stored locally on the CMM in /etc/cmm, and some SEL files are stored on the individual blades.

For the CMM, backplane, and chassis components, the CMM stores the SELs locally on the CMM in /etc/cmm.

3.6.1 CMM SEL Architecture

The SEL files stored locally on the CMM in /etc/cmm have a maximum size of 8 Kbytes. If a SEL becomes full, the CMM will wrap the SEL to the beginning, and all previous SEL entries will be cleared.

3.6.2 Satellite Management Controller (SMC) Boards

For a board inserted into the platform acting as a satellite management controller (SMC), the CMM will also store the SEL file locally. Some SMC-based boards may also contain their own SEL. Health events generated from SMC-based boards will be stored in the SEL on the CMM as well as on the SMC board if a SEL exists. When the command is issued to get the SEL from an SMC-based board, the CMM will always retrieve the SEL file stored locally on the CMM in /etc/cmm.

3.6.3 Baseboard Management Controller (BMC) Boards

For boards inserted into the system acting as a baseboard management controller (BMC), the SEL file will be stored on that particular board. All health events will be logged in the SEL on that board. When the command is issued to get the SEL from the board, the CMM will retrieve the entire SEL via IPMB from that board.

3.6.4 Retrieving a SEL

The CLI can be used to retrieve the SEL for a location. To retrieve the SEL for a particular location, issue the following get command:

cmmget -l [location] -d SEL

Where location is the component you wish to retrieve the SEL for (cmm, chassis, bladeN).

Page 39 of the Intel ZT 7102 user manual — 4.3 Synchronization
Page 39 · click to enlarge
Page 39

CMM Redundancy, Synchronization and Failover

4.0 CMM Redundancy, Synchronization and Failover

4.1 Overview

The CMM supports redundant operation with automatic failover in chassis using redundant CMM slots. In systems where two CMMs are present, one acts as the active chassis manager and the other as standby. Both CMMs monitor each other, and either can trigger a failover if necessary.

Data is always synchronized from the active CMM to the standby CMM whenever any changes occur. Existing data on the standby CMM is overwritten. A full synchronization between the active and standby CMM occurs on initial power up or insertion of a new CMM. See Table 19, “CMM Synchronization” on page 40 for a list of data items that are synchronized between the active and standby CMM.

4.2 Hardware Redundancy Specification

The following hardware interfaces exist for the support of redundancy and automatic failover:

  • Cross-connected CMM present inputs (PRES_I#) and outputs (PRES_O#)
  • Cross-connected CMM health inputs (HLY_I#) and outputs (HLY_O#)
  • Cross-connected negotiation inputs (NEG_I) and outputs (NEG_O)

The active CMM monitors its PRES_I# and HLY_I# inputs to determine if it has a healthy standby CMM. The active CMM deasserts its HLY_O# output to trigger a failover to the standby CMM.

The cross-connected negotiation signals are used to assure that only one CMM is active at a time. At any time, the standby CMM can trigger a failover by driving its NEG_O output low.

4.3 Synchronization

To ensure data on the standby CMM matches the data on the active CMM, the active CMM synchronizes its data with the standby CMM, overwriting any existing data on the standby CMM.

The CMMs will initially fully synchronize data from the active to the standby CMM approximately 30 seconds after the CMMs boot (which can take up to 2 minutes total for both CMM boot and synchronization). An insertion of a new CMM will also cause a full synchronization from the active to the newly inserted standby, which also takes 2 minutes. Partial synchronization will also occur any time files are modified or touched via the Linux* “touch” command. Date and time are synched every hour.

The following items are synchronized between CMMs. During a full synchronization, all of these files and data are synchronized. A change to any of these files results in that file being synched. The active CMM overwrites these files on the standby CMM.

Page 40 of the Intel ZT 7102 user manual — 4.3.1 Synchronization Requirements
Page 40 · click to enlarge
Page 40

Intel® NetStructureTMZT 7102 Chassis Management Module CMM Redundancy, Synchronization and Failover

Table 19. CMM Synchronization

File(s) or data Description Path:

/etc/cmm.cfg CMM’s main configuration file Ethernet

/etc/passwd Password file Ethernet

/etc/shadow Password file Ethernet

/etc/cmm/sel_* All SEL files except the CMM SEL files Ethernet

/etc/cmm/*.bin All SDR Files Ethernet

/etc/cmm/*.sif All SIF Files Ethernet

/etc/cmm/DroneList.cfg Drone mode compatible forms Ethernet

/etc/cmm/PWMMap.cfg PWM Fanspeed Mapping Ethernet

/etc/cmm/SlotLayout.cfg Chassis slot layout configuration Ethernet

/etc/var/snmpd.conf SNMP configuration files Ethernet

/etc/snmpd.conf SNMP configuration files Ethernet

/home/scripts Entire user scripts area Ethernet

date and time Date and time IPMB

IP Address Settings CMM eth1, eth1:1, and eth0 IP address settings IPMB

Blade power states Status of blade power states IPMB

Power Supply Inhibit States Status of power supplies that are inhibited by the CMM IPMB

4.3.1 Synchronization Requirements

For synchronization to occur:

  • The CMMs must be able to communicate with each other over their dedicated IPMB. The CMMs use a heartbeat via their dedicated IPMB to determine if they can communicate with each other over IPMB.
  • An Ethernet connection must exist between the two CMMs. The CMMs must be able to ping each other via Ethernet for synchronization to be successful. This can be a connection through the Ethernet switches in the chassis, which requires both switches to be present in the chassis. A connection can occur through an external Ethernet switch connected to the front ports of the CMM pair, or alternatively, the connection can be a crossover cable connecting the two front ports of the CMM pair. If synchronization fails on Eth1, it will be attempted on Eth0. If the CMMs cannot successfully ping each other via Eth0 or Eth1, synchronization cannot occur.

A failure of synchronization to occur will result in a health event being logged in the chassis SEL, however this will not inhibit a failover from occurring.

Page 41 of the Intel ZT 7102 user manual — 4.4.3 Scenarios That Failover to a Healthier Standby CMM
Page 41 · click to enlarge
Page 41

CMM Redundancy, Synchronization and Failover

4.4 CMM Failover

Once information is synchronized between the redundant CMMs, the active CMM will constantly monitor its own health as well as the health of the standby CMM. In the event of one of the scenarios listed in the sections that follow, the active CMM will automatically fail over to the standby CMM so that no management functionality is lost at any time.

4.4.1 Scenarios That Force a Failover

The following scenarios cause a failover as long as the standby CMM is operational:

  • The active CMM is pulled out of the chassis.
  • The active CMM’s HEALTHY# signal is deasserted.
  • A reboot command is issued to the active CMM.
  • The front panel reset button on the active CMM is pushed in for more than five seconds.
  • The internal synchronization code version of the active CMM is less than that of the standby CMM.

4.4.2 Scenarios That Prevent Failover

The following are reasons a failover cannot occur:

  • The active CMM cannot communicate with the standby CMM via their IPMB bus.
  • Not all data has been completely synchronized between the CMMs.

To determine the active CMM, use the CLI command:

Eth1:1 will always point to the active CMM, which will allow you to access the active CMM through the chassis at all times.

4.4.3 Scenarios That Failover to a Healthier Standby CMM

The scenarios listed below can only cause a failover if the standby CMM is in a healthier state than the active CMM. The health of the CMM is determined by computing a CMM health score, which is equal to the sum of the weights of the following active conditions. A CMM health score is determined for each CMM whenever any of these conditions occur on the active CMM. The CMM health score is composed of the sum of the weights of any of the three conditions listed below. Each condition has a default weight of 1 assigned to it, causing all conditions to have equal importance in causing failover.

To determine if a failover is necessary when one of these conditions occurs, the active CMM computes its CMM health score, and requests the health score of the standby CMM. If the score of the standby CMM is LESS than the score of the active CMM, a failover will occur. If a failover does not occur, the Chassis SEL will contain an entry indicating the reason failover did not occur.

1. SNMPTrapAddress1 ping failure: A condition is asserted and a health score is computed if the active CMM cannot ping its first SNMP trap address as defined in the SNMPTrapAddress1 setting. Only a ping failure of the first SNMP trap address (SNMPTrapAddress1) can cause the condition to assert. SNMPtrapaddress2 through SNMPtrapaddress5 do not perform this ping test.

cmmget –d redundancy

Page 42 of the Intel ZT 7102 user manual — 4.4.6 Manual Failover
Page 42 · click to enlarge
Page 42

Intel® NetStructureTMZT 7102 Chassis Management Module CMM Redundancy, Synchronization and Failover

2. Unhealthy Ethernet Switch: A condition is asserted and a health score is computed if the active CMM’s corresponding Ethernet switch is not healthy or not present. The switch health is determined by the state of the HEALTHY# hardware signal coming from the Ethernet switch. Refer to the chassis specification to see which switch corresponds to the CMM. If both CMMs have unhealthy switches or are not present in the chassis, then a failover can still occur based on other failover conditions depending on the CMM health scores.

3. Critical events on the active CMM: A condition occurs if the active CMM has critical events for any of the CMM sensors (not chassis or blade sensors). Critical events are events associated with crossing an upper or lower nonrecoverable threshold of a sensor. If both CMMs have critical CMM events, then the number of major and minor CMM events is examined to decide if a failover should occur. The number of major events is compared, and if they are equal, the number of minor events is used.

4.4.4 Scenarios That Failover to an Equally Healthy CMM

The following conditions will cause a failover only if the health score of the standby CMM is equal to that of the active CMM:

1. The ejector latch on the active CMM is opened.
2. A manual failover is executed on the active CMM.

4.4.5 Failover Timing

Times required to detect different possible failover conditions and perform data synchronization vary. For example, detecting network connection loss can take up to approximately 20 seconds. Complete synchronization typically takes 7 to 30 seconds to occur, assuming both CMMs are fully booted and a healthy Ethernet network connection and IPMB connection exist between the two CMMs). Synchronization with a newly inserted CMM can take two minutes, since a newly inserted CMM needs that time to boot and initialize.

Once the CMM data is initially synchronized, failover happens instantaneously at the hardware level. However, the CMM software requires some time to initialize various components following a failover. Software-based remote management applications accessing the CMM will need to reconnect to the newly active CMM. The newly active CMM may respond with unexpected errors while initializing.

4.4.6 Manual Failover

The following command can be issued to the active CMM to cause a failover manually to the standby CMM:

cmmset -l cmm -d failover -v 1

A manual failover can only be initiated on the active CMM. A failover will only occur if the standby CMM is at least as healthy as the active CMM. Once the command executes, the former standby CMM immediately becomes the active CMM.

If the failover could not occur, the CLI will indicate the reason why the failover could not occur, and a SEL event will be recorded.

Page 43 of the Intel ZT 7102 user manual — 5.3 Installing the CMM
Page 43 · click to enlarge
Page 43

CMM Installation and Removal

5.0 CMM Installation and Removal

This chapter describes the steps necessary to install and set up the ZT 7102 Chassis Management Module (CMM). It includes instructions on unpacking, installing, and removing the CMM. Some systems may come with the CMM(s) already installed.

5.1 Unpacking

Check the shipping carton for damage. If the shipping carton and contents are damaged, notify Intel Customer Support. Retain the shipping carton and packing material for inspection by the carrier. Obtain authorization before returning any product to Intel. Refer to Appendix G, “Customer Support” for assistance information.

5.2 Connectivity

The ZT 7102 is intended to be installed as the CMM in a system's Chassis Management Slot. Where two Chassis Management Slots are available in a system, two CMMs may be installed. (They will automatically negotiate for active and standby roles.)

The ZT 7102 is designed to operate in a backplane providing CompactPCI-style 2 mm hard metric connectors to the board's J1, J2, and J3 backplane interfaces. The backplane's CMM interfaces are specific to the CMM and do not support other 3U CompactPCI boards. See Section 2.8, “Connectors” on page 22 for connector descriptions and pinouts.

5.3 Installing the CMM

The following instructions cover the mechanical aspects of installing the ZT 7102 CMM in a compatible system. For a better understanding of what happens when a CMM is absent from a system, see “Removing the CMM” on page 44.

1. Take the necessary precautions to protect the ZT 7102 from static discharge. System power does not need to be off to install a CMM board.
2. Locate the system's dedicated CMM slot and remove the filler panel or existing CMM (see Section 5.4 for removal instructions).
Page 44 of the Intel ZT 7102 user manual — 5.4 Removing the CMM
Page 44 · click to enlarge
Page 44

Intel® NetStructureTMZT 7102 Chassis Management Module CMM Installation and Removal

3. Prepare the new/replacement CMM by opening its ejector handle (refer to Figure 8 ).
4. Carefully align the edges of the board with the card guides in the CMM slot. It may be helpful to look into the enclosure to verify correct alignment of the rails in the guides.
5. Taking care to keep the board aligned in the guides, slide the board in until the injector/ejector mechanism engages the retention bar.
6. Simultaneously push in the board and rotate the ejector handle to its closed position (rotate inward) to seat the backplane connectors.
7. If system power is on, the CMM will boot and its Status LED will light green (active CMM) or blink green (standby CMM).
8. Screw in the board retention screw to anchor the board in the chassis. This screw is located at the opposite end of the faceplate from the ejector handle. Refer to Figure 3, “Face Plate” on page 20 for the screw's location.
9. Use the CMM's Command Line Interface (CLI) to configure the CMM.

Figure 8. Ejector Handle Operation

Intel ZT 7102 — Figure 8. Ejector Handle Operation diagram (page 44)
Fig. 8 · Figure 8. Ejector Handle Operation

5.4 Removing the CMM

In CMM-based systems, the CMM controls power to every slot in the system via BD_SEL#. If a system's only CMM is removed, all the boards in the system lose power. When hot swapping a CMM, it performs a controlled shutdown of itself but not the other boards in the system. Therefore, you should ensure that the entire system is in a “safe” state before removing the CMM. The CMM's hot swap LED will not light while other boards in the system are powered on.

If a redundant CMM is available, the CMM being removed automatically fails over to the standby CMM if it is active when the ejector latch is opened. If the active CMM is being removed, the CMM status light will begin to blink indicating that a failover has occurred. The other CMM’s status light will be solid green. If a failover does not occur, check the Chassis SEL to see why a failover cannot occur. In a redundant system, the CMM's removal does not cause a loss of system power or an interruption in service (you must still wait for the blue hot swap LED to light before removing the CMM).

If the CMM loses power or is removed suddenly, the CMM's flash memory could become corrupted. If this happens, restore the board to operation using the instructions in “Updating Software” on page 127.

Page 45 of the Intel ZT 7102 user manual — Figure 8. Ejector Handle Operation
Page 45 · click to enlarge
Page 45

CMM Installation and Removal

To remove the ZT 7102 CMM from a system:

1. Unscrew the board retention screw that fastens the board to the enclosure. This screw is located at the opposite end of the faceplate from the ejector handle. Refer to Figure 3, “Face Plate” on page 20 for the screw's location.
2. If system power is off or the CMM's blue hot swap LED is on, proceed to the next step. If not, the CMM needs to be in a “safe” state before it can be removed. Signal the CMM that it is about to be removed by partially unlatching its ejector. Do not fully open the ejector as this levers the board out of the enclosure and breaks its backplane connection before the board can shut down properly.
3. Wait for the blue hot swap LED to light. It will take a few seconds to light up. The LED will not light if other boards in the system are powered on. Refer to Figure 3, “Face Plate” on page 20 for the LED's location.
4. Open the ejector handle fully, rotating it outward until the board disengages from the backplane (refer to Figure 8 for ejector handle instructions).
5. Slide the board evenly out of the enclosure.
6. Install a replacement CMM or cover the empty slot with a filler panel to maintain the system’s shielding and cooling performance.
Page 46 of the Intel ZT 7102 user manual — Figure 8. Ejector Handle Operation
Page 46 · click to enlarge
Page 46

Intel® NetStructureTMZT 7102 Chassis Management Module CMM Installation and Removal

Page 47 of the Intel ZT 7102 user manual — Figure 9. BIST Flow Chart
Page 47 · click to enlarge
Page 47

6.0 Built-In Self Test

The CMM provides for a Built-In Self Test (BIST). The test will be run automatically after power-up or front-panel reset. This test will detect flash corruption as well as other critical hardware failures.

Results for the BIST are displayed on the console through the serial port during boot time. Results of BIST will also be available through the CLI if the OS successfully boots.

If the BIST detects a fatal error, the CMM will not be allowed to function as an active CMM.

6.1 BIST Test Flow

The following state diagram shows the order of the tests RedBoot* runs following a power-up or front-panel reset. On every state before reaching active CMM, if there is an error, RedBoot will log the error event into the EEPROM, route the error message to the serial port, and continue booting. If the execution hangs before the OS loads due to the nature of the error, the CMM hangs. If the OS successfully boots, it will alert users to any errors that occurred during boot.

Figure 9. BIST Flow Chart

CMM)

FPGA, DS1307, NIC

*Other names and brands may be claimed as the property of others.

Show 11 more labels / short text on this page
Built-In Self Test · RedBoot* · FPGA Image Checksum · Image Checksum · Power Up/ · Memory Test · Reset · BlueCat* loaded (active · IPMB Bus Test · BlueCat · Image Checksum
Page 48 of the Intel ZT 7102 user manual — 6.4 Mid-BIST
Page 48 · click to enlarge
Page 48

Intel® NetStructureTMZT 7102 Chassis Management Module Built-In Self Test

The BIST is broken down into stages consisting of groups of tests run at serious times throughout the boot process. Table 20 shows the different BIST stages and the tests associated with each stage:

Table 20. BIST Implementation

Boot-BIST Early-BIST Mid-BIST Late-BIST

Strobe watchdog timer to extend timeout period Extended memory test BlueCat image checksum

FPGA image checksum FPGA version check IPMB bus test

Local PCI bus / NIC presence test

6.2 Boot-BIST

The codes in Boot-BIST will be executed at the very early stage of the RedBoot bootstrap, which is just before the FPGA programming and memory module initialization. Boot-BIST will perform checksum checking over the RedBoot image and the FPGA image. Checksum errors will be detected if there is a mismatch of between the calculated checksum and the stored checksum in FIS directory.

Boot-BIST will also perform a Base Memory Test for the first 1 Mbyte of memory. Whenever there is an error, BIST will inform the user by prompting a warning message through the console terminal and log the event to event-log area.

6.3 Early-BIST

The early BIST stage will extend the reset timeout period on the watchdog timer (MAX6374) by strobing GPIO7 on FPGA1. This prevents any possible hardware reset during the BIST process. The watchdog timer will be enabled after the ADM1026 GPIO initialization, and disabled once it reaches the RedBoot console. The OS will enable the watchdog timer again and start the strobing thread at the kernel level.

6.4 Mid-BIST

Mid-BIST will be started just after some basic modules initialization, such as flash and zlib compression. In this stage of BIST, the Extended Memory Test will be performed to scan and diagnose the possible bit errors in the memory. It starts scanning from 1 MByte to the maximum available memory size on the board. It will not test the memory below 1 MByte because portion of RedBoot has already loaded and resided on it. The memory test includes: the walking ones test, 32-bit address test, and 32-bit inverse address test. Furthermore, voltage and temperature ratings will be verified to lie within the hardware tolerable ranges. The FPGA firmware version will be checked and will alert if an older version of an FPGA image has been detected. Also, system date and time will be read out from the real time clock and displayed through the console terminal. NIC presence is also checked here. NIC self-test is not performed here because it is performed in the existing NIC driver module.

RedBoot image checksum · DS1307 RTC test · Base memory test

Page 49 of the Intel ZT 7102 user manual — 6.6 Event Log Area and Event Management
Page 49 · click to enlarge
Page 49

6.5 Late-BIST

Late-BIST involves disabling the watchdog timer to indicate a successful boot of RedBoot. It will also verify the checksum of the OS image stored in the FIS directory before proceeding with the boot script execution.

Figure 10 shows at which times during the boot cycle the various stages of BIST are performed.

Figure 10. Timing of BIST Stages

Module initialization (flash, zlib, ide)

Module initialization (ethernet interface)

banner, and execute boot script

6.6 Event Log Area and Event Management

Errors detected by the BIST are stored in an event log. The event-log area is designed to have 269 entries. Each entry is 14 bytes. The event-log area is located in EEPROM on the CMM. The BIST can place entries into the event log until it becomes full. Once full, any new entries will be lost. The BIST event log is cleared by the OS once the OS logs any BIST errors into the SEL.

Show 12 more labels / short text on this page
Built-In Self Test · HAL initialization · (processor, cache, · serial port) · Boot-BIST · FPGA programming · Memory parameters initialization · Early-BIST · Mid-BIST · Late-BIST · Display copyright · Done
Page 50 of the Intel ZT 7102 user manual — 6.7.3 CMM Failover
Page 50 · click to enlarge
Page 50

Intel® NetStructureTMZT 7102 Chassis Management Module Built-In Self Test

At OS start-up, the CMM will read the contents of BIST results in the reserved event log area and store the errors as entries in the CMM SEL. This will allow the CMM application to take the appropriate action based upon the SEL events as a result of RedBoot BIST tests. If there is not enough space to log the events in the CMM SEL, no results are logged to the CMM SEL.

The BIST event log will be erased only after the event log is stored into the CMM SEL. Event strings for BIST events are listed in Section 11.0, “Health Event Strings” on page 67.

6.7 OS Flash Corruption Detection and Recovery Design

The OS is responsible for flash content integrity at runtime. Flash monitoring under the OS environment can be divided into two parts: monitoring static images and monitoring dynamic images.

Static images refer to the RedBoot image, FPGA image and BlueCat image in flash. These images should not change throughout the lifetime of the CMM unless they are purposely updated or corrupted. The CRC for these files are written into flash when the images are uploaded.

Dynamic image refers to the OS Flash File System (JFFS2). This image will dynamically change throughout the runtime of the OS.

6.7.1 Monitoring the Static Images

A static test is run at specified time intervals during CMM operation. The interval is specified on the command line in the CMM startup script. The default interval is 24 hours. A value of zero will turn off the test. The static test will read each static image (RedBoot, FPGA, BlueCat), calculate the image checksum, and compare with the checksum in the RedBoot configuration area (FIS). If the check sum test fails, the error will be logged to the CMM SEL.

6.7.2 Monitoring the Dynamic Images

For monitoring the dynamic images, the CMM leverages the corruption detection ability from the JFFS(2) flash file system. At OS start-up, the CMM executes an initialization script to mount the JFFS(2) flash partitions (/etc and /home). If a flash corruption is detected, an event will be logged to the CMM SEL.

During normal OS operation, flash corruption during file access can also be detected by the JFFS(2) and/or the flash driver. If a flash corruption is detected, an event will be logged to the CMM SEL.

6.7.3 CMM Failover

If during normal OS operation a critical error occurs on the active CMM, such as for a flash corruption, the standby CMM will be checked to see if it is in a healthier state. If the standby CMM is in a healthier state, then a failover will occur.

Page 51 of the Intel ZT 7102 user manual — 6.8.3.3 32-Bit Inverse Address Test
Page 51 · click to enlarge
Page 51

6.8 BIST Test Descriptions

6.8.1 Flash Checksum Test

This test is targeted to verify the RedBoot image and FPGA image are not corrupted.This test will calculate the CRC32 checksum from the RedBoot image, and then compare with the image checksum stored in the FIS directory. If one mismatches another, BIST will switch to the backup image. If checksum mismatch was found from the FPGA image, BIST will load the backup image to program the FPGA device.

6.8.2 Base Memory Test

This test will write the data pattern of 55AA55AA into every 4-byte of memory below 1 Mbyte. Its objective is to verify wire connectivity of address and data pins between the memory module and the processor. The test will write the data pattern into the complete first 1 Mbyte, then verify the written data pattern by reading them out from the memory module. If the data pattern mismatches, the test will log the error event into event-log area and route error message to serial port.

6.8.3 Extended Memory Tests

6.8.3.1 Walking Ones Test

This test is targeted to verify the data bus wiring by testing the bus one bit at a time. The data bus passes the test if each data bit can be set to 0 and 1 independently of the other data bits.

6.8.3.2 32-Bit Address Test

This test is targeted to verify the address bus wiring. The smallest set of addresses that will cover all possible combinations is the set of “power-of-two” addresses. These addresses are analogous to the set of data values used in the walking 1's test. The corresponding memory locations are 0001h, 0002h, 0004h, 0008h, 0010h, 0020h, and so on. In addition, address 0000h must also be tested. The possibility of overlapping locations makes the address bus test harder to implement. After writing to one of the addresses, we must check that none of the others has been overwritten.

Note that not all of the address lines can be tested in this way. Part of the address-the left most bits-selects the memory chip itself. Another part-the right most bits-may not be significant if the data bus width is greater than eight bits. These extra bits will remain constant throughout the test and reduce the number of test addresses. For example, if the processor has 32 address bits, it can address up to 4 Gbytes of memory. If we want to test a 128 Kbyte block of memory, the 15 most-significant address bits will remain constant. In that case, only the 17 rightmost bits of the address bus can actually be tested. (128 K is 1/32,768th of the total 4 Gbyte address space.)

To confirm that no two memory locations overlap, first write some initial data value at each power-of-two offset within the device. Then a new value is written-an inverted copy of the initial value, to the first test offset. It is then verified that the initial data value is still stored at every other power-of-two offset. If a location is found, other than the one just written, that contains the new data value, you have found a problem with the current address bit. If no overlapping is found, the procedure is repeated for each of the remaining offsets.

6.8.3.3 32-Bit Inverse Address Test

This test is similar to the 32-bit address test except the addresses are tested in the inverse direction. The test helps identify a broader scope of possible addressing errors inherent in memory modules.

Built-In Self Test

Page 52 of the Intel ZT 7102 user manual — 6.8.9 IPMB Bus Busy/Not Ready Test
Page 52 · click to enlarge
Page 52

Intel® NetStructureTMZT 7102 Chassis Management Module Built-In Self Test

6.8.4 FPGA Version Check

This test is targeted to verify the correct FPGA image programmed into both FPGA chips. This test will display the FPGA version on both FPGAs. Both versions should be the same, or the user will be prompted with a warning message. If the programmed version is older than the expected, user will be prompted to upgrade to the latest FPGA image.

6.8.5 DS1307 RTC Test

This test is targeted to verify the functionality of DS1307 RTC chip. This test will display the date/time settings from the RTC and validate the readings. If any readings found to be non-BCD format, user will be prompted with warning message. This test will also capture current time, sleep a while, then compare the previously captured time and new time. If they differ, it means the RTC is working. Otherwise, user will be prompted with warning message.

6.8.6 NIC Presence/Local PCI Bus Test

This test generates the PCI bus transaction by scanning the PCI buses available on the board. This test will detect the two Ethernet devices and verify each device has the valid Vendor ID and Device ID in the PCI configuration space. NIC internal self-test will not be performed here, as the self-test will be executed when loading the Ethernet driver.

6.8.7 OS Image Checksum Test

This test is targeted to verify the OS image stored in the flash is not corrupted. This test will calculate the CRC32 checksum from the OS image, then compare with the image checksum stored in the FIS directory. If one mismatches the other, BIST will log an error event to the event-log area and route the error message to serial port.

6.8.8 CRC32 Checksum

CRC32 is the 32-bit version of Cyclic Redundant Check technique designed to ensure the bits’ validity and integrity within the data.

It first generates the diffusion table, which consists of 256 entries of double-word; each entry is known as a unique diffusion code. The checksum calculation is started by fetching the first byte in data buffer, exclusive-OR with the temporary checksum value. The resulting value will be AND-ed with 0xFF to restrict an index from 0 to 255 (decimal). That index will be used to fetch a new diffusion code from the table. Next, the newly fetched diffusion code will be exclusive-OR with the most significant 24 bits of the temporary checksum value (effectively 8 bits left-shifting the checksum value). The resulting value is the new temporary checksum value. The calculation process is repeated until the last byte in the data buffer. The final temporary checksum value becomes the final checksum value.

6.8.9 IPMB Bus Busy/Not Ready Test

This test identifies any potential FPGA lockup before loading BlueCat. If the FPGA is detected to be locked up, an event indicating which bus actually failed will be logged into the Event log.

Page 53 of the Intel ZT 7102 user manual — 7.2.2 Telnet into the CMM
Page 53 · click to enlarge
Page 53

CMM Connection and Setup

7.0 CMM Connection and Setup

7.1 CLI Overview

The Command Line Interface (CLI) connects to and communicates with the intelligent management devices of the chassis, boards, and the CMM itself. The CLI is an IPMI-based library of commands that can be accessed directly or through a higher-level management application. Administrators can access the CLI through Telnet or the CMM's serial port. Using the CLI, users can access information about the current state of the system including current sensor values, threshold settings, recent events, and overall chassis health.

7.2 Connecting to the CLI

The CMM provides two connections on its front panel (see Figure 3, “Face Plate” on page 20)

  • An Ethernet connection via an RJ-45 connector
  • An RS-232 serial port interface also via an RJ-45 connector

Either of these interfaces can be used to log into the CMM, as well as the Ethernet interface provided through the backplane of a chassis. Use Telnet to log into the CMM over a Ethernet connection, or use a terminal application or serial console over the RS-232 interface.

If logging in for the first time to set up IP addresses, use the serial port console interface to perform configuration.

7.2.1 Connecting through a Console

Connect an RS-232 serial cable with an RJ-45 connector to the serial console port on the front of the CMM. Set your terminal application settings as follows:

  • Baud – 115200
  • Data Bits – 8
  • Parity – None
  • Stop Bits – 1
  • Flow Control – Xon/Xoff or none

Connect using your terminal application.

7.2.2 Telnet into the CMM

To telnet into the CMM, point your console or telnet application to the IP address of the CMM you wish to telnet to. If you wish to telnet to the active CMM through the backplane, you can point the telnet application to the Eth1:1 IP address.

Page 54 of the Intel ZT 7102 user manual — 7.3.1 Setting IP Address Properties
Page 54 · click to enlarge
Page 54

Intel® NetStructureTMZT 7102 Chassis Management Module CMM Connection and Setup

7.2.3 FTP Into the CMM

Using an FTP client, FTP to the IP address of the CMM you wish to transfer files to or from.

7.3 Initial Setup - Logging in for the First Time

The default username for the cmm is root. The default password is cmmrootpass.

At the login prompt, enter the username: root

When prompted for the password, enter: cmmrootpass

The root password can be changed using the passwd command. For information on resetting the CMM password back to default, refer to Section 9.0, “Resetting the Password” on page 63.

7.3.1 Setting IP Address Properties

By default, the CMM assigns IP addresses statically. Eth0, the front panel Ethernet port, is configured with the static IP address 10.90.90.91. Eth1, the Ethernet port to the backplane, is configured with a static IP address of 192.168.100.92. Eth1:1, an alias of Eth1 is used to always point to and be active on the active CMM, is configured with a static IP address of 192.168.100.93.

On initial power up of a chassis with two CMMs, both CMMs will have the same IP addresses assigned by default. When the chassis is powered up, the standby CMM automatically decrements its eth1 IP address by one less than the active CMM.

Example:

1. A dual CMM Chassis is powered up.
2. Active CMM is assigned IP address of 192.168.100.92 to Eth1 on the active CMM.
3. Standby CMM is assigned IP address of 192.168.100.91 to Eth1 on the standby CMM.

At this point, the static IP addresses must be changed to appropriate values for their network configuration. Ensure that the two CMMs do not contain duplicate IP addresses on Eth0 and eth1 to avoid address conflicts on the network.

eth0 can also be set using DHCP. eth1, and eth1:1 will always remain static.

Page 55 of the Intel ZT 7102 user manual — 7.3.1.2 Setting Eth0 to DHCP
Page 55 · click to enlarge
Page 55

CMM Connection and Setup

7.3.1.1 Setting IP Information (IP Address, Netmask, and Gateway)

Eth0

1. Open the /etc/ifcfg-eth0 file using the vi editor
2. Ensure the BOOTPROTO variable is set to static.
3. Set the STATICIP variable to the IP address you want to assign to that interface.
4. Set the NETMASK variable to the appropriate netmask for your network.
5. Set the GATEWAY variable to the appropriate value for the gateway on your network
6. To activate the changes, at the user prompt, type:

/etc/rc.d/network reload

Eth1 and Eth1:1

1. Open the /etc/ifcfg-eth1 file using the vi editor
2. Set the STATICIP1 variable to the IP address you want to assign to that interface.
3. Set the STATICIP2 variable to the IP address you want to assign to the active CMM on the network. This value should ONLY be set on the active CMM, as it will be synchronized to and overwritten on the standby CMM.
4. Set the NETMASK variable to the appropriate netmask for your network.
5. Set the GATEWAY variable to the appropriate value for the gateway on your network.
6. To activate the changes, at the user prompt, type:

/etc/rc.d/network reload

7.3.1.2 Setting Eth0 to DHCP

1. Using the vi editor, change the BOOTPROTO variable in the /etc/ifcfg-eth0 file to dhcp .
2. To activate the changes, the user can reboot the CMM, or at the user prompt, type:

/etc/rc.d/network reload

Page 56 of the Intel ZT 7102 user manual — 7.3.4 Rebooting the CMM
Page 56 · click to enlarge
Page 56

Intel® NetStructureTMZT 7102 Chassis Management Module CMM Connection and Setup

7.3.2 Setting a Hostname

The hostname of the CMM is a logical name that is used to identify a particular CMM. This name is shown at login time and advertised to any DNS servers on a network.

To change the hostname:

1. Using the vi editor, change the HOSTNAME variable in /etc/HOSTNAME to the desired name.
2. To activate the changes, at the user prompt, type: /etc/rc.d/network reload

7.3.3 Setting Auto-Logout Time Limit

For security purposes, the CMM automatically logs the user out of the current console session after 15 minutes (900 seconds). This auto-logout time can be changed by editing /etc/profile and changing the TMOUT value to the desired setting. The timeout (TMOUT) value is set in seconds (900 seconds is the default). A setting of TMOUT=0 will disable the automatic logout. This can also be set at the command line, however doing so at the command line will not be persistent across a reboot of the CMM.

7.3.4 Rebooting the CMM

To reboot the CMM, type the reboot command in the CLI. Telnet sessions will have to be reestablished after the CMM is rebooted.

Do not use the “init 0” or “init 6” command to reboot the CMM as problems may result.

Page 57 of the Intel ZT 7102 user manual — Table 21. Location (-l) Keywords
Page 57 · click to enlarge
Page 57

Command Line Interface (CLI) Syntax and Arguments

8.0 Command Line Interface (CLI) Syntax and Arguments

The command line interface on the CMM supports two types of commands: cmmgets and cmmsets. Cmmgets are used to query for information, whereas cmmsets are used to write information.

8.1 cmmget and cmmset syntax

The syntax for calling the CLI from the command line is as follows:

cmmget [-h] [-l location] [-t target] -d dataitem

cmmset [-h] [-l location] [-t target] -d dataitem -v value

Where cmmget and cmmset are the CLI executables. The parameters can be in any order. The CLI is case insensitive, except for the executable name. Parameters shown in brackets are optional.

Any attribute value that contains a space must be enclosed in quotes. This happens often when specifying targets. For example, to get the current value of a sensor called Brd Temp on the CMM, the command would be:

cmmget –l cmm –t “Brd Temp” –d current

8.2 Help Parameter: -h

If the Help parameter is given, then the rest of the parameters are ignored, and the help text is output to the user.

8.3 Location Parameter: -l

The Location parameter is the location in the system that the user is executing the cmmget or cmmset on. If no location is given then the default location is the CMM. The Location keywords are shown in the following table.

Table 21. Location (-l) Keywords

cmm The Chassis Management Module.

bladeN One of the CPU boards in the chassis. N refers to the chassis slot number into which the CPU board is inserted. Refer to the chassis documentation for slot information.

system The entire platform.

chassis Chassis specific items excluding the boards (such as fan trays and power supplies).

fantrayN One of the fan trays in the system. N refers to the number of the fan tray in the system.

powersupplyN (Only works with IPMI power supplies.) One of the power supplies in the system where N is a number between 1-8.

If no location parameter is given, then the default is CMM.

Keyword Function

Page 58 of the Intel ZT 7102 user manual — Table 23. dataitem (-d) Keywords for All Locations (Sheet 1 of 2)
Page 58 · click to enlarge
Page 58

Intel® NetStructureTMZT 7102 Chassis Management Module Command Line Interface (CLI) Syntax and Arguments

8.4 Target Parameter: -t

The Target parameter is the sensor or variable that the cmmget or cmmset acts on. The Target keywords are shown in the following table.

Table 22. Target (-t) Keywords

Used to query the FRU or individual FRU fields for a specific location. For more information on querying a component’s FRU and individual FRU fields, see Section 16.0, “Obtaining FRU Information” on page 89.

SDR Sensors The sensor name as defined in its Sensor Data Record (SDR) for that component. Sensor names can be retrieved for an IPMI based location using the ListTargets Dataitem.

none Same as not entering a target.

8.5 Dataitem Parameter: -d

The Dataitem parameter is the Target or Location attribute that the user is getting or setting. Dataitem must be given for every CLI command. The Dataitem keywords are shown in the following table.

Table 23. dataitem (-d) Keywords for All Locations (Sheet 1 of 2)

Data Item Description Get/

Values:

Used to configure user defined actions when events occur. This dataitem is used with a target (–t) parameter specified sensor and a value (-v) parameter. When an event happens for that particular sensor, then the script defined in the –v parameter will be executed. The script to be executed must be located in the /home/scripts directory on the CMM and the /home/scripts path should be omitted when specifying the script. See Section 18.0, “CMM Scripting” on page 93 for more information.

Valid filename of a script that resides in

current The current value of a sensor. Get N/A

health Returns the health of the location and if any events exist. Get N/A

healthevents Returns the specific health events that are occurring on the location if any exist. Get N/A

listdataitems Used to find the data items available on a location.

The output lists dataitems that the location supports. Get N/A

Used to find what sensors or targets are available on the location. This is the list of sensors defined by the SDR for that particular location.

Used to find out if a particular location is occupied or present in the chassis. This can be blades or intelligent fan trays.

sel Returns a location's System Event Log. Get N/A

Show 15 more labels / short text on this page
Keyword Description · fru · Valid Set · Set · criticalaction · majoraction · Both · minoraction · /home/scripts · normalaction · none · listtargets · Get N/A · presence · Get N/A
Page 59 of the Intel ZT 7102 user manual — Table 25. dataitem (-d) Keywords for BladeN Locations
Page 59 · click to enlarge
Page 59

Command Line Interface (CLI) Syntax and Arguments

Table 23. dataitem (-d) Keywords for All Locations (Sheet 2 of 2)

Data Item Description Get/

Values:

All thresholds of a sensor. This includes lower non-recoverable, lower critical, lower non-critical, upper non-critical, upper critical, and upper non-recoverable.

Used to query individual thresholds for a value based sensor, such as temperature or voltage. Get N/A

eventaction Used to trigger a script based on event code of a health event. Refer to Section 18.0, “CMM Scripting” on page 93 Set The event code of the event

Table 24. dataitem (-d) Keywords for System location

Data Item Description Get/

Output:

CriticalCritList Major: MajList Minor: MinList

where each list is a list of locations having that level of health events (space separated).

In the output, PSn refers to PowerSupplyN (i.e., PS1 = PowerSupply1, PS2 = PowerSupply2, etc.)

Table 25. dataitem (-d) Keywords for BladeN Locations

Data Item Description Get/

Set Valid Set Values:

1. Add board to drone mode list

Used to add IPMI capable drone mode compatible blades to the list of recognized drone mode boards. For further information on drone mode see Section 14.0, “Drone Mode SBC Support” on page 85.

0. Delete board from drone mode list

powerstate Used to query or control the power state of a board. This is also used to reset a board. Both

Show 22 more labels / short text on this page
Valid Set · Set · thresholdsall · Get N/A · uppercritical · uppernoncritical · lowercritical · lowernoncritical · uppernonrecoverable · lowernonrecoverable · Valid Set · Set · Values · unhealthylocations · Get N/A · ignorespcirst · Set · poweron · poweroff · reset · offline · activate
Page 60 of the Intel ZT 7102 user manual — Table 27. dataitem (-d) Keywords for CMM Location (Sheet 1 of 2)
Page 60 · click to enlarge
Page 60

Intel® NetStructureTMZT 7102 Chassis Management Module Command Line Interface (CLI) Syntax and Arguments

Table 26. dataitem (-d) Keywords for Chassis Location

Data Item Description Get/

Set Valid Set Values:

Used to set or query the fan speed of all the fans in the system as a percentage of their full speed. Some fan trays may prevent the fan speed from going to zero. Querying the fan speed does not show actual fanspeed, but reflects what the CMM fan speed output is set to as a percentage of the actual full fan speed. See Section 17.0, “Fan Control and Monitoring” on page 91 for further information.

Used to set or query the value configured in the CMM for the maximum amount of time the CMM will wait for the HEALTHY # hardware signal to be asserted by an SBC.

2 (default) through 60

Location String of up to 16 characters

location Used to set or query the location field in the chassis FRU. Both

Used to set or query the value for the maximum number of tries the CMM will attempt to power up a board during the power sequencing loop.

psinhibit[1..8] Used to inhibit the power supplies in the chassis. Both 1 - Enable

Queries chassis slot layout information. This will tell the user what slots are system slots, peripheral slots, or busless slots. It will also show which slots are occupied by blades.

Table 27. dataitem (-d) Keywords for CMM Location (Sheet 1 of 2)

Data Item Description Get/

Values:

Used to engage the Alarm Cutoff (ACO) or get its value. When engaged, the ACO silences active alarms and blinks the alarm LEDs on the CMM. This Dataitem is only valid when used with the CMM as the location.

1. Set cut off
0. Unset cut off

Used to set the Alarm Cutoff timeout value (in minutes) or get its value. This is the length of time the CMM waits before automatically canceling an engaged ACO (if the user fails to cancel it manually). A value of 0 disables the timeout. This dataitem is only valid when used with the CMM as the location.

Number of minutes: 0-1000.

Value of 0 disables the timeout.

1. Turn On LED

Used to turn on or off the critical, major and minor LEDs. Set

0. Turn Off LED

Ethernet Used to change to the eth0 direction to either the front panel or the rear panel IO card. Both front (default)

Show 23 more labels / short text on this page
100 (default) · fanspeed · Both · healthyrampuptime · Both · in seconds · “ -1” (Default) · maxpowerupattempts · Both · through 2000000000 · 0- Inhibit · slotinfo · Get N/A · Valid Set · Set · alarmcutoff · Both · alarmtimeout · Both · criticalled · minorled · majorled · rear
Page 61 of the Intel ZT 7102 user manual — 8.7 Sample CLI Operations
Page 61 · click to enlarge
Page 61

Command Line Interface (CLI) Syntax and Arguments

Table 27. dataitem (-d) Keywords for CMM Location (Sheet 2 of 2)

Data Item Description Get/

Values:

Used only from the active CMM to failover to the standby CMM. This command will only successfully execute if the standby CMM is in a healthy enough state to accept a failover.

Set 1 - Failover

Used to query CMM redundancy information. Indicates CMM(s) presence, which CMM is active, which CMM is stand by, and which one the user is logged into.

version The version of the CMM software. Get N/A

Valid SNMP community name:

snmptrapcommunity Set or query the SNMP trap community string. Both

snmpenable Sets or queries the SNMP trap enabled status. Both

IP Address in the form:

snmptrapaddress[1..5] The IP address of the machines receiving SNMP traps from the CMM. Both

x.x.x.x

Valid port number:

snmptrapport Sets or queries the TCP/IP port that the SNMP trap will be sent from. Both

snmptrapversion Sets or queries the SNMP trap version. Both V1(default)

Used with the cmmget command to update the CMM firmware on the CMM.

Starts the update of the firmware on that CMM.

The syntax of the command is: cmmset -l cmm -d update -v [Update Package path and filename] [force] [overwrite] [ftp:server:user:password]

Refer toChapter 25.0, “Updating Software” for more info.

8.6 Value Parameter: -v

The Value parameter specifies the new value for a Dataitem. This parameter is required for all cmmset commands and is only used for cmmset commands. Valid value parameters are shown in with their corresponding data items in the data item tables listed above.

8.7 Sample CLI Operations

Sample CLI Operations can be found in Appendix D, “Example CLI Commands”.

Show 12 more labels / short text on this page
Valid Set · Set · failover · redundancy · Get N/A · public (default) · Enable (default) · Disable · 0-65536 · 162 (default) · update · Set
Page 62 of the Intel ZT 7102 user manual — 8.8 Generating a System Status Report
Page 62 · click to enlarge
Page 62

Intel® NetStructureTMZT 7102 Chassis Management Module Command Line Interface (CLI) Syntax and Arguments

8.8 Generating a System Status Report

The CLI includes an executable script (cmmdump) that is used to generate a system status report for use in communicating system health and configuration information to technical support personnel. This is useful in helping technical support successfully troubleshoot any issues that may be affecting the system. Cmmdump outputs system information to the screen by default or to a file. To send the output to a file use the following command:

The filename should refer to a file that is in a valid directory (i.e., /home/cmmdump.txt). The file can then be retrieved off the CMM using FTP (see Section 7.2.3, “FTP Into the CMM” on page 54).

cmmdump > [filename]

Page 63 of the Intel ZT 7102 user manual — 9.2 Resetting the Password in a Dual CMM System
Page 63 · click to enlarge
Page 63

9.0 Resetting the Password

It may become necessary to reset the CMM password to its default of cmmrootpass. The CMM has an onboard dip switch labeled SW1-1 to perform this action. See Section 2.10, “Onboard Switches” on page 31 for the location of the switch. Setting the switch and powering up the CMM will cause the password to reset to its default. The CMM then must be removed, and the switch must be turned off again.

9.1 Resetting the Password in a Single CMM System

For non-redundant systems that contain only a single CMM, resetting the password requires removing the CMM. This causes any boards that are power controlled by the CMM to power off.

1. If necessary, safely shut down and power off boards being power controlled by the CMM.
2. Remove the CMM from the system.
3. Turn on the dip switch SW1-1. The dip switch has a label indicating which way is on.
4. Reinsert the CMM into the system and allow the CMM to fully boot into Bluecat Linux*.
5. Once at the login prompt, the password should now be reset to its default of cmmrootpass .
6. Log in to the CMM to ensure the password was reset.
7. Remove the CMM from the system.
8. Turn off dip switch SW-1 by moving it back to its original off position.
9. Reinsert the CMM into the system and allow the CMM to fully boot into Bluecat Linux.
10. Log in to the CMM and operate as normal.

9.2 Resetting the Password in a Dual CMM System

In redundant systems containing dual CMMs - one active, one standby - the password should be reset on the standby CMM. Once reset to its default, the default password will synchronize itself to the active CMM. This prevents the need to perform the reset on both CMMs and a failover.

1. Open the ejector latch on the standby CMM and wait for the blue hot swap LED to illuminate, indicating the CMM is safe to remove from the system.
2. A health event will occur on the active CMM indicating redundancy has been lost. A SEL entry will be recorded, and a trap will be sent out.
3. Remove the standby CMM from the chassis.
4. Turn on the dip switch SW1-1. The dip switch has a label indicating which way is on.
5. Reinsert the CMM into the system and allow the CMM to fully boot into Bluecat Linux.
6. A health event will occur indicating that the passwords on both CMMs have been reset and was synched from the standby CMM.
7. Once at the login prompt, the password should now be reset to its default of cmmrootpass .
8. Login to the active CMM to ensure the password was reset.

Resetting the Password

Page 64 of the Intel ZT 7102 user manual — 9.0 Resetting the Password
Page 64 · click to enlarge
Page 64

Intel® NetStructureTMZT 7102 Chassis Management Module Resetting the Password

9. Open the ejector latch on the standby CMM and wait for the blue hot swap LED to illuminate, indicating the CMM is safe to remove from the system.
10. A health event will occur on the active CMM indicating redundancy has been lost. A SEL entry will be recorded, and a trap will be sent out.
11. Remove the standby CMM from the chassis.
12. Turn off the dip switch SW1-1.
13. Reinsert the CMM into the system and allow the CMM to fully boot into Bluecat Linux.
14. The password can now be set on the active CMM and it will get synched to the standby CMM and the CMM can now be operated normally.
Page 65 of the Intel ZT 7102 user manual — 10.2.1 Discrete Sensor Events
Page 65 · click to enlarge
Page 65

10.0 Sensor Types

The CMM provides access to and can log events from different IPMI sensor types. These sensors can be threshold based sensors or discrete sensors, depending on the type of reading and events they generate. For more information on sensors and sensor types, refer to the Intelligent Platform Management Interface Specification v1.5.

10.1 Threshold-Based Sensors

Threshold based sensors are sensors that generate or change an event status based on comparing a current value to a threshold value for a given hardware monitor device. Examples of threshold based sensors are temperature, voltage, and fan tachometer sensors.

10.1.1 Threshold-Based Sensor Events

Threshold-based sensors generate events when a current value for a device becomes greater than or less than a given threshold value. The IPMI specification defines six thresholds that can be assigned to a given sensor. The sensor will generate an event when its current reading goes above or below any of these thresholds. The severity of the event generated depends on which threshold is crossed. These six thresholds and their associated event severity are as follows:

Upper non-recoverable---> Critical Event Upper critical--->Major Event Upper non-critical--->Minor Event Lower non-critical--->Minor Event Lower critical--->Major Event Lower non-recoverable--->Critical Event

10.2 Discrete Sensors

Discrete sensors are sensors that have a predefined set of states. An examples of a discrete sensor would be board presence, where a board is either present or not present.

10.2.1 Discrete Sensor Events

Discrete sensors can generate events on state changes. The severity of the event is determined by the CMM. Discrete sensor events for the CMM are located in the next section, Chapter 11.0, “Health Event Strings”.

Sensor Types

Page 66 of the Intel ZT 7102 user manual — 10.0 Sensor Types
Page 66 · click to enlarge
Page 66

Intel® NetStructureTMZT 7102 Chassis Management Module Sensor Types

Page 67 of the Intel ZT 7102 user manual — 11.1.2 SEL Event Syntax
Page 67 · click to enlarge
Page 67

11.0 Health Event Strings

This section describes the health event strings that are associated with CMM events and includes the syntax and severity of these strings. Refer to Section 10.0, “Sensor Types” on page 65 for more information on the different types of sensors.

11.1 Syntax of Health Event Strings

Health event string is a string that is associated with the particular health event occurring. Active events are displayed in a healthevents query using the following command in the CLI:

cmmget -l [location] [-t [target]] -d healthevents

Active health events are also returned when healthevents queries are executed over SNMP. In addition, all health events are logged in the SEL and sent out as SNMP Traps.

11.1.1 “healthevents” Query Event Syntax

The following is the syntax of a string returned by a healthevents query for an associated active health event. The \n represents newline characters (seen as in SNMP queries).

[Timestamp]\n [ Severity ] Event[ SDR Sensor Name ] [ Health Event String ]\n
  • Timestamp is in the format: [Day] [Month] [Date] [HH:MM:SS] [Year]. For example, Thu Dec 11 22:20:03 2003
  • Severity is either Minor, Major, or Critical.
  • SDR Sensor Name is the name given to the sensor in the Sensor Data Record (SDR).
  • Health Event Strings are listed in Section 11.4, “List of Possible Health Event Strings” on page 70 .

11.1.2 SEL Event Syntax

The following is the syntax of each SEL entry for an associated health event. The \n represents newline characters and the \t represents tab characters.

[Timestamp]\n \t[SDR Sensor Name]\t[Health Event String]\n \n

  • Timestamp is in the format: [Day] [Month] [Date] [HH:MM:SS] [Year]. For example, Thu Dec 11 22:20:03 2003
  • SDR Sensor Name is the name given to the sensor in the Sensor Data Record (SDR).
  • Health Event Strings are listed in Section 11.4 .

Health Event Strings

Page 68 of the Intel ZT 7102 user manual — Table 28. CMM Sensor Targets
Page 68 · click to enlarge
Page 68

Intel® NetStructureTMZT 7102 Chassis Management Module Health Event Strings

11.1.3 SNMP Trap Event Syntax

The following is the syntax of each SNMP trap for an associated event:

Time : [TimeStamp] , Location : [ChassisLocation] , Chassis Serial # : [ChassisSN] , Board : [Location] , Sensor : [SDR Sensor Name] , Event : [Health Event String]

  • Timestamp is in the format: [Day] [Month] [Date] [HH:MM:SS] [Year]. For example, Thu Dec 11 22:20:03 2003
  • ChassisLocation is the chassis location information recorded in the chassis FRU.
  • ChassisSN is the chassis serial number recorde in the chassis FRU.
  • Location is the location where the sensor generating the event is located (i.e., CMM)
  • SDR Sensor Name is the name given to the sensor in the Sensor Data Record (SDR).
  • Health Event Strings are listed in Section 11.4, “List of Possible Health Event Strings” on page 70 .

11.2 Sensor Targets

Available sensors for a location can be retrieved with the listtargets dataitem argument of the cmmget command. To view a list of sensor targets on the cmm using the listtargets command:

cmmget -l cmm -d listtargets

The CMM lists the following sensors that can be queried for health events:

Table 28. CMM Sensor Targets

Brd Temp Board Temperature Sensor

+1.5V +1.5 Volt Sensor

+2.5V +2.5 Volt Sensor

+3.3V +3.3 Volt Sensor

+5V +5 Volt Sensor

Eth0 Interface Eth0 LAN Sensor

Eth1 Interface Eth1 LAN Sensor

Eth1:1 Interface Eth1:1 LAN Sensor

TASensor1 Telco Alarm Input Sensor 1

TASensor2 Telco Alarm Input Sensor 2

BIST Built-in Self Test Sensor Type

For complete lists of sensors on other components (i.e., voltage sensors on blade1), refer to the corresponding Technical Product Specification for that product.

Sensor Target Description

Page 69 of the Intel ZT 7102 user manual — 11.3.3 No Active Events
Page 69 · click to enlarge
Page 69

11.3 Healthevents Queries

Healthevents queries, whether done from the CLI or through SNMP, output the same event strings and syntax for active events. This section explains the various types of output that are retrieved from healthevents queries. For more information on using the healthevents dataitem, refer to Section 8.0, “Command Line Interface (CLI) Syntax and Arguments” on page 57.

11.3.1 HealthEvents Queries for Individual Sensors

Executing a healthevents query on a particular sensor target returns all active healthevents for that sensor target in a concatenated string. One sensor may have multiple events. For example, running the following healthevents query on the CMM BIST sensor:

cmmget -l cmm -t BIST -d healthevents

might return multiple events that are active on the BIST sensor in a concatenated string like this:

Mon Feb 2 19:51:05 2004 Major Event : BIST RTC Not Working Mon Feb 2 19:51:09 2004 Major Event : BIST Both Ethernet interfaces are not working.

11.3.2 HealthEvents Queries for All Sensors on a Location

Executing a healthevents query on the “cmm” location in the CLI without a target specified (cmmget -l cmm -d healthevents) returns all the healthevents for all CMM sensors in a concatenated string. This includes all BIST, LAN, Telco Alarm, Voltage, and Temp sensors on the CMM. This ability to retrieve all healthevents on a location also applies to the chassis, bladeN, FantrayN and powersupplyN* locations.

* - PowersupplyN healthevents are dependent on the presence of IPMI-compliant power supplies. The “pwr supply N” target on the chassis location is used for querying non-IPMI capabilities of power supplies (i.e., Failure Detected). Querying the healthevents on the chassis location will return all active events for all “pwr supply N” targets.

The CMM’s SNMP interface provides a “cmm” target that can be found in the listtargets ouput. This target is used to execute healthevents queries for all active events on the CMM. Since each OID in the MIB requires a target on the location, the “cmm” target was implemented in SNMP to give the user the ability to do a healthevents query of the cmm location equivalent to the CLI command “cmmget -l cmm -d healthevents”. Similar SNMP-specific targets also exist for chassis and bladeN that allow users to retrieve all active events for that location. Refer to Section 19.0, “SNMP” on page 97 for more information on SNMP.

11.3.3 No Active Events

When a healthevents query is executed in the CLI on a target that doesn’t have active events a string will be returned that is a single line string with no timestamp or severity. Only this string will be returned and won’t be concatenated with any other strings. For example, doing a healthevents query from the CLI of a location or target that doesn’t have any active healthevents will return the following string:

“[Target] has no problems.” - i.e., “chassis has no problems” or “temp snsr 1 has no problems”

Health Event Strings

Page 70 of the Intel ZT 7102 user manual — 11.4 List of Possible Health Event Strings
Page 70 · click to enlarge
Page 70

Intel® NetStructureTMZT 7102 Chassis Management Module Health Event Strings

Executing a healthevents query through SNMP on a target with no active events returns different values than the CLI does. When a healthevents query is executed in SNMP on:

  • A location target (i.e., in SNMP, the cmm target on the cmm location) that has no active events, the value returned is a zero length string.
  • An individual sensor (i.e., the +3.3V sensor on the CMM) that has no active events, the value returned is a null value.

11.3.4 Not Present or Non-IPMI Locations

Doing a healthevents query of a blade or powersupply, or a target on a blade or powersupply, that is not present or non-IPMI compliant will return one of the following:

“BPM Blade Not Present.” - if querying an empty blade slot. “BPM Non IPMI Blade.” - if querying a blade that is present but doesn’t support IPMI. “Power Supply Not Present.” - if querying an empty power supply slot or a power supply that doesn’t support IPMI.

11.4 List of Possible Health Event Strings

Table 29 through Table 40 list possible event strings for sensors on the CMM, chassis, fan tray, and powersupply. Each event will log an entry in the SEL and generate an SNMP Trap, and can be retrieved through a healthevents query on a target or location. Locations and sensor names are listed as well.

The event severity is not displayed in the SEL entry or the SNMP trap. The severity of the event (Minor, Major, or Critical) is displayed in a healthevents query while the event is active. OK HealthEvents are displayed in healthevents queries for only a limited time when they are asserted.

For each event, the event code is listed in base 10 format for use with event scripting, which is documented in Section 18.0, “CMM Scripting” on page 93.

The table for threshold-based sensors is common to other threshold-based sensors on other components (e.g., voltage, temp, current).

Page 71 of the Intel ZT 7102 user manual — Table 30. Power Supply Event Strings (PowerSupplyN)
Page 71 · click to enlarge
Page 71

11.4.1 All Locations

Table 29. Threshold-Based Sensor Event Strings (Voltage, Temp, Current, Fan)

Event String Event Code Event Severity

"Lower non-critical going low asserted " 16 Minor

"Lower non-critical going high asserted " 17 Minor

"Lower critical going low asserted" 18 Major

"Lower critical going high asserted" 19 Major

"Lower non-recoverable going low asserted" 20 Critical

"Lower non-recoverable going high asserted" 21 Critical

“Upper non-critical going low asserted" 22 Minor

“Upper non-critical going high asserted" 23 Minor

"Upper critical going low asserted" 24 Major

"Upper critical going high asserted" 25 Major

"Upper non-recoverable going low asserted" 26 Critical

"Upper non-recoverable going high asserted" 27 Critical

"Lower non-critical going low deasserted " 28 OK

"Lower non-critical going high deasserted " 29 OK

"Lower critical going low deasserted" 30 OK

"Lower critical going high deasserted" 31 OK

"Lower non-recoverable going low deasserted" 32 OK

"Lower non-recoverable going high deasserted" 33 OK

"Upper non-critical going low deasserted" 34 OK

"Upper non-critical going high deasserted" 35 OK

"Upper critical going low deasserted" 36 OK

"Upper critical going high deasserted" 37 OK

"Upper non-recoverable going low deasserted" 38 OK

"Upper non-recoverable going high deasserted" 39 OK

11.4.2 PowerSupplyN Location (IPMI-Compliant Supplies Only)

Table 30. Power Supply Event Strings (PowerSupplyN)

Event String Event Code Event severity

"Power Supply feed lost" 51 Critical

“Power Supply feed lost or out of range” 52 Critical

"Recovered from error conditions" 48 OK

Health Event Strings

Page 72 of the Intel ZT 7102 user manual — Table 31. BIST Event Strings (BIST) (Sheet 1 of 2)
Page 72 · click to enlarge
Page 72

Intel® NetStructureTMZT 7102 Chassis Management Module Health Event Strings

11.4.3 CMM Location

Table 31. BIST Event Strings (BIST) (Sheet 1 of 2)

Event String Event Code Event Severity

“Boot is Successful.” 112 OK

“Event-log area full.” 113 Critical

“RedBoot image corrupted.” 114 Major

“Backup RedBoot image corrupted.” 115 Critical

“FPGA image corrupted. Using backup image.” 116 Major

“Backup FPGA image corrupted.” 117 Critical

“OS image corrupted.” 118 Critical

“Base memory test failed.” 119 Critical

“Extended memory test failed.” 120 Critical

“FPGA1 firmware outdated.” 121 Minor

“FPGA2 firmware outdated.” 122 Minor

“FPGA 1+2 version mismatched.” 123 Minor

“RTC date is invalid.” 124 Major

“RTC time is invalid.” 125 Major

“RTC is not working.” 126 Critical

“One of the Ethernet interfaces is not working.” 127 Minor

“Both Ethernet interfaces are not working.” 128 Major

“CMM Boot.” 129 OK

“IPMB bus [0-29] busy/not ready.” 130 - 159 Major

“Software update successful.” 160 OK

“Update of RedBoot failed.” 161 Critical

“Update of FPGA failed.” 162 Critical

“Update of Bluecat OS failed.” 163 Critical

“Update of /etc failed.” 164 Critical

“Restore of /etc files failed.” 165 Critical

“Software update failed.” 166 Critical

“Standby CMM has completed FPGA re-programming.” 179 OK

“FPGA re-programmed 2 times and no further lockup detected.” 180 Minor

“FPGA re-programmed 3 times and no further lockup detected.” 181 Minor

“FPGA re-programming has failed.” 182 Critical

“FPGA re-programmed more than 3 times and lockup still detected.” 183 Critical

“Dynamic FLASH image corruption detected.” 184 Critical

“Static Redboot image is corrupt.” 185 Critical

“Static OS image is corrupt.” 186 Critical

“Static FPGA image is corrupt.” 187 Critical

“Primary FRU unreadable - using Secondary" 188 Minor

Page 73 of the Intel ZT 7102 user manual — Table 35. Chassis Power Supply Event Strings (Pwr Supply N)
Page 73 · click to enlarge
Page 73

Table 31. BIST Event Strings (BIST) (Sheet 2 of 2)

Event String Event Code Event Severity

"FRU unreadable!" 189 Critical

"RTC battery power lost." 190 Critical

"I2C failure while reading RTC." 191 Critical

"Primary FRU is corrupted." 272 Major

"Secondary FRU is corrupted." 273 Major

"FRU is corrupted!" 274 Critical

Table 32. Telco Alarm Sensor Event Strings (TASensor[1,2])

Event String Event Code Event Severity

“asserted.” 96 Major

“deasserted.” 97 OK

Table 33. LAN Sensor Event Strings (Eth[0,1,1:1] Interface)

Event String Event Code Event Severity

“Duplicate IP address detected on the network.” 84 Major

“Duplicate IP address corrected.” 85 OK

11.4.4 Chassis Location

Table 34. Fan Tray Presence Event Strings (Fan Tray [1-3] Presence)

Event String Event Code Event Severity

"Fan Tray Removed" 64 Major

"Fan Tray Inserted" 65 OK

Table 35. Chassis Power Supply Event Strings (Pwr Supply N)

Event String Event Code Event Severity

"Recovered from error conditions" 48 OK

"Power Supply Failure detected" 49 Critical

"Power Supply Degraded" 50 Minor

“Power Supply detected” 53 OK

“Power Supply removed” 54 Major

Health Event Strings · \

Page 74 of the Intel ZT 7102 user manual — Table 38. CMM Failover Event Strings (CMM Failover)
Page 74 · click to enlarge
Page 74

Intel® NetStructureTMZT 7102 Chassis Management Module Health Event Strings

Table 36. Slot Event Strings (Slot N Event)

Event String Event Code Event Severity

"Blade Removed" 192 OK

“Blade Presence Detected” 193 OK

"Blade Deasserted HEALTHY#" 194 OK

"Blade Asserted HEALTHY#" 195 OK

“Blade Failed HEALTHY# After Maximum Attempts” 196 OK

“Blade Powered On” 197 OK

“Blade Powered Off” 198 OK

“Blade Reset” 199 OK

“Blade set to Offline” 200 OK

“Blade set to Active” 201 OK

“Blade is not IPMI capable” 202 OK

"Blade is IPMI capable" 203 OK

Table 37. CMM Redundancy Event Strings (CMM [1-2] Redundancy)

Event String Event Code Event Severity

"Lost due to switch failure" 210 Major

"Lost due to unhealthy signal" 211 Major

"Lost due to failed network connectivity between the CMM and the Primary SNMP trap destination (SNMPTrapAddress1)." 212 Major

"Lost due to CMM removal" 213 Major

"Lost due to CMM reboot" 214 Major

"Lost due to critical event on the CMM" 215 Major

"Lost due to inability to communicate with the other CMM over its management bus." 216 Major

"Lost due to incompatible firmware versions on the CMMs. Please upgrade the CMMs to the same version." 239 Major

Table 38. CMM Failover Event Strings (CMM Failover)

Event String Event Code Event Severity

"Failover occurred." 217 OK

"Failover occurred because of switch failure." 218 OK

"Failover occurred because of failed network connectivity between the CMM and the Primary SNMP trap destination." 219 OK

"Failover occurred because of critical CMM health events." 220 OK

"Failover occurred because of a bad hardware signal from the other CMM." 221 OK

"Failover occurred because it was forced by the user." 222 OK

"Regained" 208 OK · "Established" 209 OK

Page 75 of the Intel ZT 7102 user manual — Table 40. Chassis Sensor Event Strings
Page 75 · click to enlarge
Page 75

Table 38. CMM Failover Event Strings (CMM Failover)

Event String Event Code Event Severity

"Failover occurred because the other CMM rebooted." 223 OK

"Failover cannot occur because the other CMM has a bad switch." 224 OK

"Failover cannot occur because the other CMM has lost network connectivity with its Primary SNMP trap destination." 225 OK

"Failover cannot occur because the other CMM has critical health events." 226 OK

"Failover cannot occur because the other CMM is not responding over its management bus." 227 OK

"Failover cannot occur because the critical items have not been synced." 228 OK

“Failover cannot occur because the other CMM has a bad hardware signal.” 229 OK

“Failover occurred because the active CMM had older firmware than the newly active CMM.” 240 OK

Table 39. CMM File Sync Event Strings (CMM File Sync)

Event String Event Code If HealthEvents, its

"Could not copy the /etc/CMM.cfg file to the standby CMM." 230 OK

"Could not copy the /etc/passwd and /etc/shadow files to the standby CMM." 231 OK

“Default password files synced to active CMM. Passwords have been reset to default.” 232 OK

"Could not copy the /etc/sel_* files to the standby CMM." 233 OK

"Could not copy the /etc/snmpd.conf and /etc/var/snmpd.conf files to the standby CMM." 234 OK

"Could not copy the SDR file to the standby CMM." 235 OK

"Could not copy the /etc/scripts directory to the standby CMM." 236 OK

"All files successfully synced." 237 OK

Table 40. Chassis Sensor Event Strings

Event String Event Code Event Severity

“No PCI connectivity record found in chassis FRU information.” 256 Critical

“cmm.sif file not found. Cannot scan CMM sensors.” 257 Critical

“chassis.sif file not found. Cannot scan Chassis sensors.” 258 Critical

Health Event Strings · severity

Page 76 of the Intel ZT 7102 user manual — Table 39. CMM File Sync Event Strings (CMM File Sync)
Page 76 · click to enlarge
Page 76

Intel® NetStructureTMZT 7102 Chassis Management Module Health Event Strings

Page 77 of the Intel ZT 7102 user manual — 12.2.1.2 Peripheral Boards
Page 77 · click to enlarge
Page 77

12.0 Slot Power Control

The chassis management module controls power to the node and fabric slots of a chassis using the BD_SEL# and HEALTHY# hardware signals. The CMM can power up, power down, and reset a board in a particular slot, as well as to place a slot into an offline mode. The CMM can also be used to query the power state of a board at any time.

12.1 Difference between a Board’s HEALTHY# Signal and a Board’s Health

Confusion may arise as to the difference between the HEALTHY# hardware signal coming from a board and the board’s health retrieved using the CLI command:

cmmget -l bladeN -d health

A board’s HEALTHY# signal is a PICMG-specified hardware signal on the CompactPCI connector. The PICMG 2.0 specification defines HEALTHY# to be a signal generated by a board’s hot swap control logic. At a minimum, HEALTHY# should be asserted by the hot swap control when all of the voltages are good. Additional logic may be implemented above this to generate the HEALTHY# signal. The CMM uses the HEALTHY# hardware signal to determine when a board is powered up completely.

The board’s health, as returned by the CLI command listed above, is used to determine whether there are any active health events occurring on a particular board, such as temperature or voltage violations.

12.2 Slot Power-Up Sequence

The CMM constantly polls the status of the BD_SEL# lines coming from the node and fabric slots. Boards inserted into the chassis will pull the BD_SEL# line to Vcc, indicating insertion of the board.

12.2.1 Assertion of BD_SEL#

Upon detection of board insertion, the CMM determines whether to assert BD_SEL# based on the type of board being inserted and the type of slot the board is being inserted to.

12.2.1.1 System Master Boards

For system master boards in system master slots, the CMM will always assert BD_SEL#.

12.2.1.2 Peripheral Boards

For peripheral boards inserted into peripheral slots, the CMM will ONLY assert BD_SEL# if a system master board is present for that PCI segment. If a peripheral board is inserted into a system master slot, or into a peripheral slot in a PCI segment with no system master, the CMM will not assert BD_SEL# for that board.

Slot Power Control

Page 78 of the Intel ZT 7102 user manual — 12.3 Obtaining the Power State of a Board
Page 78 · click to enlarge
Page 78

Intel® NetStructureTMZT 7102 Chassis Management Module Slot Power Control

12.2.1.3 Fabric and PCI-Less Slots

For node slots containing no PCI bus (PCI-less slots) as well as fabric slots, the CMM will always assert BD_SEL#.

12.2.1.4 Drone Mode Boards

For drone mode capable boards that have been added to the CMM, the CMM will always assert BD_SEL# regardless of the type of node slot where they are inserted. For more information on drone mode and drone mode boards, see Section 14.0, “Drone Mode SBC Support” on page 85. All Intel SBCs are recognized as drone mode capable.

12.2.2 Assertion of HEALTHY# During Power-Up

Upon assertion of BD_SEL#, the CMM will wait a minimum of two seconds for the board to assert the HEALTHY# signal. The amount of time the CMM will wait for HEALTHY# to be asserted by an SBC can be configured from the CMM interfaces from 2 to 60 seconds and is referred to as the HEALTHY# ramp up time. See Section 12.5, “Power Sequencing Commands and Policies” on page 79 for instructions on how to set and retrieve the HEALTHY# ramp-up time.

A board should generate a HEALTHY# signal indicating all of its onboard voltages are good per the PICMG 2.1 R2.0 specification. Depending on the logic of the board, HEALTHY# can also be generated by additional logic, such as from a BIST, OS boot-up, etc.

If within the defined HEALTHY# ramp-up time the CMM detects HEALTHY# being asserted, the CMM will leave BD_SEL# asserted, and the board will go through its normal power-on sequence. BD_SEL# will remain asserted unless the HEALTHY# signal gets deasserted for that board or the command to power down a board is issued.

If within the defined HEALTHY# ramp-up time the CMM does not detect HEALTHY# being asserted, the CMM will deassert BD_SEL# to that slot, and that board will not power up. If the board remains inserted in the slot, the process will repeat on the next polling cycle of that slot. This process will continue until either the board powers up, the board is removed from the slot, or the maximum number of power up attempts is reached.

The maximum number of attempts the CMM will try to power on a board can be configured through the CMM interfaces. See Section 12.5, “Power Sequencing Commands and Policies” on page 79 for further information on how to set and retrieve the maximum power-up attempts.

12.3 Obtaining the Power State of a Board

The CMM can obtain the power state information of a board at any time by issuing the following command:

cmmget -l bladeN -d powerstate

Where N is the number of the slot in which the blade you are querying resides. This command will give information on whether the blade is present, the state of the HEALTHY# signal (asserted/ deasserted), whether the board has been powered up or not, and whether the slot is in the active or offline mode. Output will look similar to this:

Board is present

Page 79 of the Intel ZT 7102 user manual — 12.5 Power Sequencing Commands and Policies
Page 79 · click to enlarge
Page 79

Board HEALTHY# signal is asserted

Board has been powered up by the CMM

Board is in active mode.

For further information on active and offline mode see Section 15.0, “Active vs. Offline Slots” on page 87.

12.4 Controlling the Power State of a Slot

The CMM can power a slot off, on, reset the slot, or place a slot in an offline mode. Placing a slot in offline mode allows the CMM to ignore the state of the HEALTHY# signal from that slot.

12.4.1 Powering Off a Board

The following command will power a board off:

cmmset -l bladeN -d powerstate -v poweroff

N is the number of the slot the blade to be powered down resides in. Once issued, the command will ask for confirmation by entering “y” before continuing.

12.4.2 Powering On a Board

The following command will power a board on:

cmmset -l bladeN -d powerstate -v poweron

N is the number of the slot the blade to be reset resides in.

12.4.3 Resetting a Board

The following command will reset a board:

cmmset -l bladeN -d powerstate -v reset

N is the number of the slot the blade to be reset resides in. Once issued, the command will ask for confirmation by entering “y” before continuing.

12.5 Power Sequencing Commands and Policies

The following section describes how to set and retrieve the HEALTHY# ramp up time and maximum power up attempts for the chassis.

HEALTHY# ramp up time is used to determine the maximum amount of time the CMM will wait for an SBC to generate the HEALTHY# hardware signal during the current power sequencing loop. If the amount of time defined in the healthyrampuptime expires, the CMM deasserts BD_SEL# to the slot, and continues through the power up sequence loop. For example, on initial power up, if the healthyrampuptime is set to two seconds, a blade can be reset during its powerup sequence. If set to 60 seconds, a reset command won’t take effect until 60 seconds after power on in which time the blade will typically be booted.

Slot Power Control

Page 80 of the Intel ZT 7102 user manual — 12.5.4 Setting the Maximum Power-Up Attempts
Page 80 · click to enlarge
Page 80

Intel® NetStructureTMZT 7102 Chassis Management Module Slot Power Control

The maximum power-up attempts variable is used to configure the number of times the CMM will attempt to power on a board during the power sequencing loop. Once the maxpowerupattempts is exceeded for a particular board, the CMM will no longer attempt to power on the board by asserting the BD_SEL# signal during the power sequencing loop.

Setting these variables applies to the entire chassis, not just a single board or slot.

12.5.1 Retrieving the Healthy# Ramp-Up Time

Issuing the following command will retrieve the value configured in the CMM for the maximum amount of time the CMM will wait for the HEALTHY # hardware signal to be asserted by an SBC.

cmmget -l chassis -d healthyrampuptime

This returns the time (in seconds) the CMM will wait for an SBC to generate the HEALTHY# hardware signal for ALL node slots in the chassis. This time can range from 2 to 60 seconds. The default is 2 seconds.

12.5.2 Setting the Healthy# Ramp-Up Time

The following command can be used to set the maximum amount of time in seconds the CMM will wait for the HEALTHY# hardware signal to be asserted all SBCs in the chassis.

cmmset -l chassis -d healthyrampuptime -v [time]

Where time is a value between 2 and 60 seconds. The default is 2 seconds.

Setting this value applies to all boards in the chassis. For every newly inserted board, or every board being powered on, the CMM will always wait the allotted healthyrampuptime, even if the board asserts HEALTHY# before healthyrampuptime expires.

12.5.3 Retrieving the Maximum Power-Up Attempts

The following command is used to retrieve the configured value for the maximum number of tries the CMM will attempt to power up a board during the power sequencing loop.

cmmget -l chassis -d maxpowerupattempts

The default value for maxpowerupattempts is -1, and indicates an infinite number of attempts will be made by the CMM to power up boards in the chassis. This value applies to all boards in the chassis.

12.5.4 Setting the Maximum Power-Up Attempts

The following command is used to set the value for the he maximum number of tries the CMM will attempt to power up boards in the chassis during the power sequencing loop.

cmmset -l chassis -d maxpowerupattempts -v “[# of attempts]”

Where # of attempts is the desired number of attempts the CMM should try to power up boards in the chassis enclosed in quotes. The default is a value of “ -1” and indicates the CMM will try an infinite number of times to power up boards.

Page 81 of the Intel ZT 7102 user manual — 12.5.5 Power Sequencing SEL Events
Page 81 · click to enlarge
Page 81

Setting a value of “0” will cause the CMM to discontinue attempting to power up boards in the chassis. Rebooting the chassis when the value is set to “0” will prevent the CMM from powering up any blades in the chassis.

The maximum value that can be set for maxpowerupattempts is 2000000000.

This value applies to all boards in the chassis. Changing this value to a greater value with boards that failed to power by reaching the previous maximum power up attempts will cause the CMM to incrementally attempt to power up the board with the difference between the two maximums. For example, for a board that failed to power up with a maxpowerupattempts of 5, changing the maximumpowerupattempts to a value of 12 will cause the CMM to attempt to power up that board an additional seven more times.

Failure of a board to power after reaching the maximum number of attempts will cause a SEL event to be logged indicating this.

12.5.5 Power Sequencing SEL Events

The following power sequencing events will cause an event to be recorded in the chassis SEL.

1. CMM detects the presence or removal of a board

Slot X Event Blade Presence Detected

Slot X Event Blade Removed

2. CMM detects the assertion/deassertion of the HEALTHY# signal from the board

Slot X Event Blade Asserted HEALTHY#

Slot X Event Blade Deasserted HEALTHY#

3. CMM detects a board has failed to power up after reaching the maximum power up attempts

Slot X Event Blade Failed HEALTHY# After Maximum Attempts

4. CMM detects the powering on or off of a board

Slot X Event Blade Powered On

Slot X Event Blade Powered Off

5. CMM detects a board has reset

Slot X Event Blade Reset

6. CMM detects a slot has been placed in offline or active

Slot X Event Blade set to Offline

Slot X Event Blade set to Active

Slot Power Control

Page 82 of the Intel ZT 7102 user manual — 12.5.5 Power Sequencing SEL Events
Page 82 · click to enlarge
Page 82

Intel® NetStructureTMZT 7102 Chassis Management Module Slot Power Control

Page 83 of the Intel ZT 7102 user manual — 13.4 Precautions For Inhibiting Power Supplies
Page 83 · click to enlarge
Page 83

13.0 Power Supplies

13.1 Power Supply Detection

Unlike blades, there is no hardware support for the detection of power supply presence. Therefore, an additional process is used to periodically scan for the presence of IPMI power supplies. Specifically, every five seconds, the process sends an IPMI GetDeviceID to each of the possible power supply slots. If a response is received, then it is known that an IPMI power supply is present.

13.2 Inhibit, Degrade, and Fail Signals

The CMM and power supplies do share several hardware signals that provide some limited functionality. These signals work with existing (non-IPMI) power supplies and are expected to work in the same way for the IPMI power supplies. The Inhibit signal is an output from the CMM that can be used to effectively turn off a power supply. Querying the Inhibit signal will indicate whether the CMM has inhibited the supply or not. When a power supply degrades or fails, it signals these conditions to the CMM using the Degrade and Fail inputs.

The CMM can detect if any power supply is Degraded or Failed, then it can be deduced that there is a power supply present. The new feature provided by IPMI supplies is the ability to detect the presence of a power supply when the power supply is operating normally.

13.3 Inhibiting Power Supplies

The CMM has the ability to inhibit any of the power supplies in the chassis. Each power supply can be inhibited individually.

The state of inhibited power supplies is synchronized from the active to the standby CMM. If a failover were to occur, the inhibited power supplies would remain inhibited.

The state of inhibited power supplies is not persistent across chassis power cycles.

13.4 Precautions For Inhibiting Power Supplies

Care should be taken when inhibiting power supplies. Inhibiting certain supplies or groups of supplies may cause the loss of power to portions of the chassis, including power to the CMMs. It is also possible to inhibit all of the power supplies, which causes a loss of power to the entire chassis, including the CMMs.

Once the CMMs lose power, they are no longer able to drive the INHIBIT# line to the power supplies, which causes all of the supplies to power up again. Losing power to both CMMs is equivalent to power cycling the chassis.

Care should be taken to prevent inhibiting all of the supplies in a chassis as well as losing power to both CMMs so that the reset condition does not occur.

Power Supplies

Page 84 of the Intel ZT 7102 user manual — 13.6 Enabling Power Supplies
Page 84 · click to enlarge
Page 84

Intel® NetStructureTMZT 7102 Chassis Management Module Power Supplies

13.5 Inhibiting Power Supplies

Power supplies can be inhibited through the CMM. This is accomplished using the following command:

cmmset -l chassis -d psinhibitN -v 0

Where N is the number of the power supply that is to be inhibited.

13.6 Enabling Power Supplies

To enable a supply which has been inhibited, issue the following command:

cmmset -l chassis -d psinhibitN -v 1

Where N is the number of the power supply that is to be enabled.

Page 85 of the Intel ZT 7102 user manual — 14.0.2 Removing a Drone Mode Capable SBC
Page 85 · click to enlarge
Page 85

Drone Mode SBC Support

14.0 Drone Mode SBC Support

An SBC is said to be “drone mode capable” if it can be configured to ignore the PCI_RST# signal coming from the PCI bus when inserted in a peripheral slot in a CompactPCI chassis. In this “drone mode,” the board is operating independently of the PCI bus.

Because it is not acting as a peripheral on the PCI bus, and therefore not dependant on the system master for correct initialization and power up, the normal methods used by the CMM for power sequencing a peripheral board do not apply to the drone board in that PCI segment. This allows two things to occur for drone boards that normally wouldn’t occur for standard peripheral boards:

  • A drone mode capable board can be powered up in a peripheral slot without the system master slot being populated and running for that particular PCI segment.
  • If the system slot board is extracted/goes unhealthy, the drone mode capable boards in that particular PCI segment should not be powered off.

14.0.1 Adding a Drone Mode Capable SBC

The CMM maintains an internal table of drone mode capable SBCs. For the CMM to recognize a drone mode capable board, it must also support IPMI 1.0 or above in addition to being able to operate in a drone mode. To add a drone mode capable SBC to the table issue the following CLI command, substituting the appropriate blade number for N:

cmmset -l bladeN -d IgnoresPCIRst -v 1

Once this command is issued, the CMM will send a GetDeviceID command to the blade and retrieve its manufacturer and product ID. It then adds this information to its internal table of drone mode capable SBCs. That drone mode capable SBC can now be configured to operate in drone mode and placed in any node slot within the chassis thereafter.

The CMM will then treat any board whose manufacturer and product ID match the one listed in the table as drone mode capable.

14.0.2 Removing a Drone Mode Capable SBC

To remove a drone mode SBC from the internal table on the CMM, issue the following command:

cmmset -l blade5 -d IgnoresPCIRst -v 0

This removes the listing for that manufacturer and product ID from the internal table on the CMM, and any boards matching this manufacturer and product ID thereafter will be treated as standard CompactPCI system or peripheral boards.

Page 86 of the Intel ZT 7102 user manual — 14.0 Drone Mode SBC Support
Page 86 · click to enlarge
Page 86

Intel® NetStructureTMZT 7102 Chassis Management Module Drone Mode SBC Support

Page 87 of the Intel ZT 7102 user manual — 15.4 Limitations of the Offline Mode
Page 87 · click to enlarge
Page 87

Active vs. Offline Slots

15.0 Active vs. Offline Slots

A slot operating normally is in what is defined as an active mode. The CMM has the capability to place a slot in an offline mode. In an offline mode the CMM ignores the HEALTHY # signal from the board in terms of power sequencing, and also does not send any health events that occur on the board. Placing a slot into offline mode allows for troubleshooting and debugging an unhealthy board.

If the board has an IPMI controller on it that is powered by IPMB power (standby), the CMM can access the IPMI controller and hardware monitors connected to it even if the board itself has powered down. A slot in which a board goes unhealthy can be placed into the offline mode so that the CMM can get information from the IPMI controller and hardware monitors on the board which can be used to diagnose problems with the board.

15.1 Determining the State of a Slot

Slots are set by default to the active mode, which allows for normal CompactPCI operation. A cmmget of the powerstate of a slot can be used to determine if a slot has been placed into an offline mode. See Section 12.3, “Obtaining the Power State of a Board” on page 78 for more information on obtaining the powerstate of a slot.

15.2 Setting a Slot to Offline Mode

The following command will place a slot in offline mode:

cmmset -l bladeN -d powerstate -v offline

N is the number of the slot to be placed in an offline mode.

15.3 Setting a Slot to Active Mode

The following command will place a slot into the active mode for normal operation:

cmmset -l bladeN -d powerstate -v activate

N is the number of the slow to be placed into the active mode.

15.4 Limitations of the Offline Mode

The CMM does not deassert BD_SEL# and power to an offline slot. Thus, when presence for an offline slot is queried, it will return as present even with the board extracted from the slot.

Also, because the CMM does not recognize board extractions/insertions in an offline slot due to BD_SEL# remaining asserted, the slot should be placed into active mode before a new board is inserted into a slot in the offline mode. If this is not done, the CMM retains all of the information of the board that was in the slot when it was placed in the offline mode.

Page 88 of the Intel ZT 7102 user manual — 15.0 Active vs. Offline Slots
Page 88 · click to enlarge
Page 88

Intel® NetStructureTMZT 7102 Chassis Management Module Active vs. Offline Slots

Page 89 of the Intel ZT 7102 user manual — 16.2 FRU Query Syntax
Page 89 · click to enlarge
Page 89

16.0 Obtaining FRU Information

The CMM has the ability to obtain FRU information from IPMI 1.0 and higher compliant devices. The entire FRU can be retrieved, or individual fields from the FRU.

16.1 FRU Information

The FRU of an IPMI compliant device should be compliant with the “Platform Management FRU Information Storage Definition v1.0.” In this specification, the FRU can contain information in any, all or none of the following areas: chassis info, board info, and product info.

The CMM can query the entire FRU of a device, entire areas of a FRU, or individual fields in the different areas of the FRU.

For detailed information on FRUs, please refer to the “Platform Management FRU Information Storage Definition v1.0.”

16.2 FRU Query Syntax

To query FRU information, the CMM uses FRU as its target (-t) parameter. The format for querying the FRU of a particular location is:

cmmget -l [location] -t fru -d [FRUdataitem]

Where location is the component for which the FRU information is to be retrieved from, and FRUdataitem is the field(s) of the FRU which will be retrieved.

Table 41 lists the various FRU data items and the information they retrieve.

Table 41. Dataitems Used With FRU Target (-t) to Obtain FRU Information (Sheet 1 of 2)

all Returns all FRU information for the location (Not supported over SNMP)

boardall Lists all board area FRU information for the location (Not supported over SNMP)

boarddescription Lists the description field in the FRU board area for the location

boardmanufacturer Lists the manufacturer field in the FRU board area for the location

boardpartnumber Lists the part number field in the FRU board area for the location

boardserialnumber Lists the serial number field in the FRU board area for the location

boardmanufacturedatetime Lists the manufacture date and time field in the FRU board area for the location

productall Lists all product area FRU information for the location (Not supported over SNMP)

productdescription Lists the description field in the FRU product area for the location

productmanufacturer Lists the manufacturer field in the FRU product area for the location

productmodel Lists the model field in the FRU product area for the location

productpartnumber Lists the part number field in the FRU product area for the location

Obtaining FRU Information · Data Item Description

Page 90 of the Intel ZT 7102 user manual — 16.3 Chassis FRU Validity Check
Page 90 · click to enlarge
Page 90

Intel® NetStructureTMZT 7102 Chassis Management Module Obtaining FRU Information

Table 41. Dataitems Used With FRU Target (-t) to Obtain FRU Information (Sheet 2 of 2)

productserialnumber Lists the serial number field in the FRU product area for the location

productrevision Lists the revision field in the FRU product area for the location

chassisall Lists all chassis area FRU information for the location

chassispartnumber Lists the part number field in the FRU chassis area for the location

chassisserialnumber Lists the serial number field in the FRU chassis area for the location

chassislocation Lists the location field in the FRU chassis area for the location

chassistype Lists the type field in the FRU chassis area for the location

listdataitems Displays a list of all of the FRU dataitems that can be queried for the FRU target

16.3 Chassis FRU Validity Check

Chassis FRU validity is read on a periodic basis (every 24 hrs). A reuse/redefinition of two existing BIST FRU error messages in place when one or both of the Chassis FRU cannot be read. When the FRU (usually primary) cannot be read, and another message for when both primary and secondary cannot be read

"Primary FRU unreadable - using Secondary"

These two error messages are now used if the chassis FRU is detected to be corrupt will be a SEL entry and an error message will go into /home/log/error.log

Data Item Description · "FRU unreadable!"

Page 91 of the Intel ZT 7102 user manual — 17.2 Automatic Fan Control
Page 91 · click to enlarge
Page 91

Fan Control and Monitoring

17.0 Fan Control and Monitoring

The CMM controls the fan speeds and the fan tray LEDs. In a healthy state (no events) the LED changes to a green color. If any of the fan tray sensors (temperature, voltages, fan tachs) are in an unhealthy state, the LED changes to orange.

17.1 Setting Fan Speed

The factory default fan speed is 100 percent. The user can set the fan speed to 100 percent, 80 percent and 0 percent of the full speed through any of the supported interfaces. Setting the fan speed from the CMM changes the fan speeds for all of the fans in the chassis. Setting the fan speeds to 0 percent turns off the fans.

The following command can be used to set the fan speed:

cmmset -l chassis -d fanspeed -v [100, 80, 0]

Where the value is 100 for 100 percent, 80 for 80 percent, or 0 for off.

17.1.1 Considerations for Turning Off the Fans

Some fan tray designs will not allow the fans to be turned off and will override the CMM setting with hardware on the fan trays. The CMM cannot detect fan tray hardware that provides such an override. Consult the fan tray or chassis documentation for further information on setting fan speeds.

For fan trays that do not allow fans to be turned off, querying the fanspeed on the CMM after setting it to zero will still show the fanspeed as set to zero because this is what is being output by the CMM.

Also, setting the fan speed to 0 (off) will override the automatic fan control of the CMM. Temperature and fan tray events will no longer cause the CMM to drive the fans to full speed.

17.2 Automatic Fan Control

The CMM will drive the fans to full speed (100 percent) under any of the following conditions:

  • An upper temperature threshold is violated in the platform, including blades.
  • A fan tray is removed from the chassis.
  • A fan tachometer crosses a lower threshold.
  • A fan board controller has a failure.

The fans are also driven to full speed automatically if both CMMs are removed from the chassis.

Page 92 of the Intel ZT 7102 user manual — 17.3 Querying Fan Tray Sensors
Page 92 · click to enlarge
Page 92

Intel® NetStructureTMZT 7102 Chassis Management Module Fan Control and Monitoring

Note: Once the CMM automatically drives the fan speeds to 100 percent because of one of the above health events, it is still possible to set the fan speeds to 80 or 0 through the supported interfaces (CLI, etc). Once the automatic override of the fan speeds has been deactivated by resetting the fan speed to 80 or 0, the fans will remain at the newly set speed even after the condition that caused the automatic override has cleared.

17.3 Querying Fan Tray Sensors

To query the fan trays and fan tray sensors, use fantrayN as the location (-l) of the cmmget command, where N is the number of the fan tray being queried. For example, to query the current value of FANTK1 on fantray1, issue the command:

cmmget -l fantray1 -t “FANTK1” -d current

Page 93 of the Intel ZT 7102 user manual — 18.2 Associating Scripts to Event Severity
Page 93 · click to enlarge
Page 93

18.0 CMM Scripting

18.1 CLI Scripting

In addition to calling the CLI directly, commands can easily be called through scripts using “bash” shell scripting. These scripts could be tailored to create a single command from several CLI commands or to give more detailed information. For example, you may want to display all of the fans and their speeds on the server. A script could be written that would first call the CLI to find out what fan trays are present. Next it would find out what fan sensors are in each fan tray. Finally it would call the CLI to get the current speeds of each of the fans.

Scripts can be written directly on the CMM and should be saved on the CMM as a file in flash in the /home/scripts directory.

18.1.1 Script Synchronization

Script files are not synchronized automatically when copied or changed (by deleting, renaming, altering its chown/chmod/chgrp permissions, etc) in the /home/scripts directory on the active CMM. The Linux “touch” command should be issued to the /home/scripts directory on the active CMM to synchronize the scripts. Scripts are automatically synchronized on any full synchronization (chassis power up, insertion of a new CMM) as well as when they are edited (i.e., using vi and writing the file).

Scripts need to be deleted from both CMMs manually. Deleting a script on the active CMM does not automatically delete the script on the standby.

18.2 Associating Scripts to Event Severity

Health events triggered on the CMM can be used to execute scripts stored locally in the /home/scripts directory. Any level of an event can be used as a trigger: normal, minor, major, and critical.The CLI command for associating a script with an event is:

cmmset –l [location] –t [target] –d [action type] –v [script]

Location is the component in the chassis that the health event is associated with.

Target is the sensor to be triggered on.

Action type is NormalAction, MinorAction, MajorAction, or CriticalAction based upon the severity of the event to be triggered on.

Script is the script file or executable in the /home/scripts directory to be run including parameters to be sent to the script. The script and parameters should be enclosed in quotes. The script parameter should not include the /home/scripts path.

CMM Scripting

Page 94 of the Intel ZT 7102 user manual — 18.3.1 Event Codes
Page 94 · click to enlarge
Page 94

Intel® NetStructureTMZT 7102 Chassis Management Module CMM Scripting

For example, if you wanted to run a blade powerdown script called “powerbladedown” stored in /home/scripts when the ambient temperature triggered a major event for a blade 4, the command would be:

cmmset –l blade4 –t “Ambient Temp” –d MajorAction –v “bladepowerdown 4”

In this example, the /home/scripts/bladepowerdown script or executable will be executed with “4” as a parameter when blade4’s Ambient Temp sensor generates a major health event.

18.2.1 Listing Scripts Associated With Events

The scripts that are associated with events are put into the /etc/cmm.cfg file. To display a list of scripts associated with events, cat the /etc/cmm.cfg file.

For further information on event scripting commands and its arguments, see Section 7.0, “CMM Connection and Setup” on page 53.

18.2.2 Removing Scripts From an Associated Event

To remove scripts from occurring for an event in which they have been associated, issue the following command:

cmmset –l [location] –t [target] –d [action type] –v none

Location is the component in the chassis that the health event is associated with.

Target is the sensor that was being triggered on.

Action type is NormalAction, MinorAction, MajorAction, or CriticalAction based upon the severity of the event that was being triggered on.

18.3 Setting Scripts for Specific Individual Events

The CMM allows scripts to be associated with specific events which may not necessarily be health related, such as the insertion or removal of a board from the chassis. This allows any single event that can occur on the CMM to have an associated script, or scripts with it.

18.3.1 Event Codes

To allow the user to set scripts based on any event, a unique event code is assigned to each event that can occur on the CMM. The list of events and the codes associated with each event is detailed in Section 11.0, “Health Event Strings” on page 67.

Page 95 of the Intel ZT 7102 user manual — 18.5 Slot Events
Page 95 · click to enlarge
Page 95

18.4 Setting Event Scripts

Setting event scripts can be done using any of the standard CMM interfaces (CLI, SNMP, RPC). The format for the CLI command is as follows:

cmmset -l [location] -t [Sensor Name] -d EventAction -v [Event Code]:[script to be run]

This setting gets written to the cmm.cfg file and is synced to the standby CMM. It is persistent across boots.

18.5 Slot Events

The CMM treats slot related events by assigning a sensor to each slot. These sensors will be called "Slot X Event" where X is the slot number. These will be discrete sensors and will show up in the chassis "listtargets" command. This allows an event script like to be associated to slot related events like any other sensor type.

For example, to launch a script called "Notify" when blade 5 is removed, the user would execute:

cmmset -l chassis -t "Slot 5 Event" -d EventAction -v [Removal Event Code]:Notify

Assigning sensors to slot based events affects the strings shown in SNMP traps and SEL entries for slot events. The SEL entry and trap messages will now reflect the following:

Slot [Blade Number] Event [Event]

Where Event will be a string such as "Blade inserted", "Slot powered off", etc.

CMM Scripting

Page 96 of the Intel ZT 7102 user manual — 18.4 Setting Event Scripts
Page 96 · click to enlarge
Page 96

Intel® NetStructureTMZT 7102 Chassis Management Module CMM Scripting

Page 97 of the Intel ZT 7102 user manual — B0473-01
Page 97 · click to enlarge
Page 97

SNMP

19.0 SNMP

The CMM supports the Simple Network Management Protocol (SNMP). The CMM can support SNMP queries and send SNMP traps in v1 or v3. The SNMP interface on the CMM very closely mirrors that of the CLI in both syntax and function.

The following diagram shows the high-level layout of the SNMP/MIB components and the flow of the data via SNMP protocol.

Figure 11. High Level SNMP/MIB Layout

DMM MIB

SNMP Trap Get/ Get-next/ Set

CMM

SNMP

CMM API

Software Linux* System Call

* Other names and brands may be claimed as property of others.

B0473-01

Show 7 more labels / short text on this page
MIB/SNMP Manager · Agent · CMM/MIB-ll · Modules (calls API) · SNMP Trap · Utility · CMM Management
Page 98 of the Intel ZT 7102 user manual — 19.3 SNMP Agent
Page 98 · click to enlarge
Page 98

Intel® NetStructureTMZT 7102 Chassis Management Module SNMP

19.1 CMM MIB

The CMM comes with a text file (ZT 7102.mib) that describes the CMM objects to be managed, as well as all of the managed objects in the platform. A remote application such as an SNMP/MIB manager can compile and read this file and utilize this information to manage the sensor devices on CMM, chassis, and server blades currently present. The ZT 7102.mib is located in the /usr/local/cmm directory in the CMM. Users can utilize ftp or rcp to get this file from the CMM.

19.2 MIB Design

The CMM supports the following MIB II objects. The writeable objects can be set in their respective fields in the /etc/snmpd.conf file.

Table 42. MIB II Objects - System Group

Object Syntax Size Access Value

sysDscr DisplayString 0..127 read-only “Linux ZT 7102 2.4.2-1 #156 [DATE] armv5”

Date is the actual current date.

iso(1).org(3).dod(6).internet(1).private(4).enter prises(1).intel(343).products(2).Chassis-Mana gement(14).ZT 7102(1)

sysObjectID OBJECT IDENTIFIER read-only

sysUpTime Days and Time read-only Time since ZT7102 began running

sysContact DisplayString 0..127 read-write max. 128 bytes

sysName DisplayString 0..8 read-write Default:”ZT 7102”

sysLocation DisplayString 0..127 read-only

Table 43. MIB II - Interface Group

Object Syntax Size Access Value

ifDscr DisplayString 0..127 read-only 10/100BASE-TX

19.2.1 CMM MIB Objects

Detailed descriptions of the MIB objects can be found in the ZT7102.mib file located on the CMM.

19.2.2 Querying Non-IPMI Compliant Blades and Power Supplies

Slot control is a target that is specific to SNMP that is displayed in response to a listtargets command when used on an unoccupied slot in the chassis. This target is not available if the slot is occupied. The Slot Control target allows the user to perform other commands against that slot without an IPMI-compliant blade or IPMI-compliant power supply present.

19.3 SNMP Agent

The SNMP agent (snmpd) listens to SNMP v1 queries (gets/sets) by default, evokes the corresponding MIB Module to process the request, and sends the SNMP response with return data to the SNMP/MIB manager. All SNMP “set” queries are logged in the command log file.

Page 99 of the Intel ZT 7102 user manual — 19.3.4 Setting up an SNMP v3 MIB Browser
Page 99 · click to enlarge
Page 99

SNMP

19.3.1 Configuring the SNMP Agent Port

The SNMP agent is set up to use port 161 by default. The port can be configured to use a different port number by adding the following line to the snmpd.conf file:

19.3.2 Configuring the Agent to Respond to SNMP v3 Requests

The agent can also be configured to respond to SNMP v3 queries, in which case it checks the security, decodes the request, then evokes the corresponding MIB Module to process the request, and sends the SNMP response with return data to the SNMP/MIB manager. SNMP v3 adds support for strong authentication and private communication.

To change the SNMP agent to respond to SNMP v3 queries:

1. Copy /etc/snmpdv3.conf to /etc/snmpd.conf.
2. Find the process ID of the snmpd process by issuing the command:
3. Look for the snmpd process. There may be more than one, so use the lowest process ID, which is the first instance of the process. The listing will look similar to this:

121 ? SN 0:00 /usr/sbin/snmpd -c /etc/snmpd.conf

4. Restart the snmpd agent by issuing the following command:

kill -s SIGHUP [snmpd_process_id]

Where snmpd_process_id is the process ID of the snmpd process found in the step above.

19.3.3 Configuring the Agent Back to SNMP v1

To reconfigure the agent back to SNMP v1, follow the same steps as above, substituting the /etc/snmpdv1.conf for /etc/snmpdv3.conf. The rest of the process is the same.

19.3.4 Setting up an SNMP v3 MIB Browser

To manage the CMM via SNMPv3 MIB browser/manager (mg-soft, net-snmp, etc.), the user needs to configure the browser with the following parameters:

1. Load and compile the ZT 7102.MIB file
2. Set the SNMPv3 security parameters:

— Set SNMPv3 agent user

— At default, Userroot

— Set the MD5 Authentication password: cmmrootpass

— Set the DES Encryption password: cmmrootpass

agentaddress port_number · ps -ax

Page 100 of the Intel ZT 7102 user manual — 19.5.2 Enabling and Disabling SNMP Traps
Page 100 · click to enlarge
Page 100

Intel® NetStructureTMZT 7102 Chassis Management Module SNMP

19.4 SNMP Trap Utility

The SNMP trap utility is utilized by the CMM management software to send SNMP trap messages to a remote application regarding any abnormal system events. When enabled, the CMM will issue SNMP v1 traps on port 162. The CMM can also be configured to issue SNMP v3 traps. The SNMP trap port can also be configured. For a description of all the traps that are issued, refer to Section 11.0, “Health Event Strings” on page 67.

19.4.1 Configuring the SNMP Trap Port

To configure the SNMP Trap Port to a different port number, issue the command:

cmmset -l cmm -d SNMPTrapPort -v [Port Number]

Where Port Number is the desired SNMP Trap Port number.

19.4.2 Configuring the CMM to Send SNMP v3 Traps

To configure the CMM to send SNMP v3 Traps, issue the command:

cmmset -l cmm -d SNMPTrapVersion -v v3

19.4.3 Configuring the CMM to Send SNMP v1 Traps

To configure the CMM to send SNMP v1 Traps, issue the command:

cmmset -l cmm -d SNMPTrapVersion -v v1

19.5 Configuring and Enabling SNMP Trap Addresses

The CMM allows up to five SNMP trap addresses destinations, SNMPTrapAddress1-5. In redundant CMM systems, SNMP Trap Address 1 MUST be set to a valid IP address on the network that the CMM can ping to at all times. This is used as a test of network connectivity as well as being the first SNMP Trap Address.

19.5.1 Configuring an SNMP Trap Address

To configure an SNMP trap address, issue the command:

cmmset -l cmm -d SNMPTrapAddressN -v [IP address]

where N is the number of the trap address from 1 to 5 that is being set, and IP address is the IP address of the trap receiver.

19.5.2 Enabling and Disabling SNMP Traps

SNMP Trap addresses are enabled by default. To disable SNMP traps, issue the command:

cmmset -l cmm -d SNMPenable -v disable

To enable SNMP trap addresses, issue the command:

cmmset -l cmm -d SNMPenable -v enable

Page 101 of the Intel ZT 7102 user manual — 19.7 snmpd.conf
Page 101 · click to enlarge
Page 101

SNMP

To check the status of SNMP traps, issue the command:

cmmget -l cmm -d SNMPenable

19.5.3 Alerts Using SNMPv3

The CMM utilizes the SNMPtrap utility to send the SNMPv3 ‘trap’ message. For receiving the SNMPv3 Trap, the remote application such as the trap listener needs to:

1. Set the SNMPv3 Trap User. The default trap user is root .
2. Set the MD5 Authentication password. The default MD5 Authentication password: is publiccmm .
3. Set the DES Encryption password. The default DES Encryption password is publiccmm .

19.5.4 Alert Using UDP Alert

The CMM Management software also sends the alert via UDP port 10000. The IP address to receive this alert is the same as the SNMP Trap IP addresses. The UDP alert is enabled by default when the user enables SNMP traps.

19.6 Security Model

19.6.1 SNMPv3 Security: Authentication Protocol and Privacy Protocol

The CMM supports the highest security level for SNMPv3. The MD5 is used for authentication Protocol in the CMM. The DES is used for Privacy Protocol in the CMM. When in this mode, the user needs to specify each password (authKey, privKey) for these protocols. The SNMPv3 packet is securely encrypted during the transmission.

This is the default security level of the CMM when configured for SNMP v3.

The following fields are defined to handle all SNMPv3 security levels:

Table 44. SNMPv3 Security Fields

SecurityName user name Default Value:

AuthProtocol authentication type (MD5)

AuthKey authentication password publiccmm

PrivProtocol privacy type (DES)

PrivKey privacy password publiccmm

19.7 snmpd.conf

For more information regarding SNMP configuration, and the snmpd.conf file, please visit:

http://www.net-snmp.org/man/snmpd.conf.html

Page 102 of the Intel ZT 7102 user manual — 19.5.3 Alerts Using SNMPv3
Page 102 · click to enlarge
Page 102

Intel® NetStructureTMZT 7102 Chassis Management Module SNMP

Page 103 of the Intel ZT 7102 user manual — 20.2 Using the RPC Interface
Page 103 · click to enlarge
Page 103

RPC

20.0 RPC

In addition to the command-line interface, the CMM may be administered by custom remote applications through an RPC.

RPC calls are useful for managing the CMM from:

  • A remote machine through the management network
  • Another blade in the same chassis as the CMM, through the chassis backplane network
  • An application running on the CMM itself

The RPC interface supports the same functionality as the command-line interface.

20.1 Setting Up the RPC Interface

Before you can use RPC calls in a custom application, you must download the following RPC source code files from the Intel developer web site located at:

http://developer.intel.com/design/network/products/cbp/zt7102.htm

  • rcliapi.h
  • rcliapi_xdr.c
  • rcliapi_clnt.c
  • cli_client.c
  • cli_client.h

The first three files should be compiled and linked into the application under development. These files implement the RPC calling subsystem for use in an application.

The file cli_client.c contains a small sample program for calling the CMM through RPC. These files currently support Linux and VxWorks*. Future revisions may support Microsoft* Windows*.

The last file, cli_client.h, contains declarations and function prototypes necessary for interfacing with the RPC calling subsystem. Include the file in a ‘#include’ statement in all application files that make RPC calls.

20.2 Using the RPC Interface

The RPC interface may be used to manage the CMM whether the calling application is on a remote network, on a blade in the same chassis as the CMM, or even running on the CMM itself.

The following two functions are defined by the RPC subsystem for calling the CMM through RPC:

  • GetAuthCapability()
  • ChassisManagementApi()
Page 104 of the Intel ZT 7102 user manual — 20.2.2 ChassisManagementApi()
Page 104 · click to enlarge
Page 104

Intel® NetStructureTMZT 7102 Chassis Management Module RPC

20.2.1 GetAuthCapability()

The following is the calling syntax for GetAuthCapability():

char* pszCMMHost, char* pszUserName, char* pszPassword );

Parameters pszCMMHost:

[in] IP Address or hostname of CMM pszUserName:

[in] A valid CMM user name pszPassword:

[in] Password corresponding to pszUserName

Authentication successful. The return value is the authentication code.

Invalid username / password combination.

E_RPC_INIT_FAIL

RPC initialization failure.

E_RPC_COMM_FAIL

RPC communication failure.

GetAuthCapability is used to authenticate the calling application with the remote CMM. The remote CMM will not respond to RPC communications until the application has successfully authenticated. To authenticate, the application will need to pass the CMM’s current IP address, username and password to GetAuthCapability(). The default username and password are ‘root’ and ‘cmmrootpass’. When the authentication is successful authentication, GetAuthCapability() will return an authentication code for use with all further RPC communication.

20.2.2 ChassisManagementApi()

The following is the calling syntax for ChassisManagementApi():

char* pszCMMHost, int nAuthCode, unsigned int uCmdCode, unsigned char* pszLocation, unsigned char* pszTarget, unsigned char * pszDataItem, unsigned char * pszSetData,

int GetAuthCapability( · Return Value >0 · int ChassisManagementApi(

Page 105 of the Intel ZT 7102 user manual — RPC
Page 105 · click to enlarge
Page 105

RPC

void ** ppvbuffer, unsigned int * uReturnType );

[in] IP Address or DNS hostname of CMM.

[in] Authentication code returned by GetAuthCapability().

[in] The command to be executed (CMD_GET or CMD _SET as defined in cli_client.h).

[in] The location that contains the data item that uCmdCode acts upon, such as system, CMM, or blade1.

[in] The target that contains the attribute that uCmdCode acts upon, such as the sensor name as listed in the Sensor Data Record (SDR). When not applicable, use "NA” (such as when pszDataItem is an attribute of the pszLocation rather than pszTarget.

[in] The attribute that uCmdCode acts upon, either an attribute of pszLocation or pszTarget.

[in] The new value to set. When not applicable, use "NA”.

[out] A pointer to the buffer containing the returned data.

[out] The type of data that ppvbuffer points to (see the defines in cli_client.h).

The value definitions of the return codes may be found in Table , “” on page 106.

Once the application has authenticated, it may proceed to get and set CMM parameters by calling ChassisManagementApi(). For each call to ChassisManagementApi(), the calling application must pass in the authentication code returned from GetAuthCapability(). The get and set commands available through ChassisManagementApi() are the same as those available on the command-line interface with cmmget and cmmset.

For more information on the command-line interface, see Section 8.0, “Command Line Interface (CLI) Syntax and Arguments” on page 57.

Show 9 more labels / short text on this page
Parameters pszCMMHost · nAuthCode · uCmdCode · pszLocation · pszTarget · pszDataItem · pszSetData · ppvbuffer · uReturnType
Page 106 of the Intel ZT 7102 user manual — Table 45. Error and Return Codes for the RPC Interface (Sheet 1 of 4)
Page 106 · click to enlarge
Page 106

Intel® NetStructureTMZT 7102 Chassis Management Module RPC

Table 45. Error and Return Codes for the RPC Interface (Sheet 1 of 4)

Code #Error Code String Error Code Description

1 E_BPM_BLADE_NOT_PRESENT Blade isn't in the chassis

2 E_ECMM_SVR_COMMAND_UNSUPPORTED ECMM_SVR: Unsupported Command Error

3 E_CLI_MSG_SND CLI Send Message Error

4 E_CLI_INVALID_TARGET Not a valid -t parameter.

5 E_CLI_INVALID_LOCATION Not a valid -l location.

6 E_CLI_INVALID_DATA_ITEM Not a valid -d parameter.

7 E_CLI_INVALID_SET_DATA Not a valid -v parameter.

8 E_CLI_INVALID_REQUEST CLI Invalid Request Error

9 E_CLI_MSG_RCV CLI Receive Message Error

10 E_CLI_NO_MORE_DATA No data found to retrieve.

11 E_CLI_DATA_TYPE_UNSUPPORTED CLI Data Type Unsupported

12 E_ECMM_CLIENT_CONNECT_ERROR ECMM_CLIENT: RPC Connect Error

13 E_ECMM_SVR_AUTH_CODE_FAIL Invalid auth code passed to RPC interface

14 E_CLI_STANDBY_CMM Operation cannot Be Performed on Standby CMM

15 E_WP_INITIALIZING The CMM is Initializing and Not Ready. Wait a few seconds and try again.

16 E_BPM_NON_IPMI_BLADE Blade does not support IPMI

17 E_BPM_STANDBY_CMM BPM Operation cannot Be Performed on Standby CMM

18 E_BPM_NO_MORE_DATA Couldn't delete a board from the drone mode list

19 E_BPM_INVALID_SET_DATA Not a valid -v parameter

20 E_CLI_INVALID_BUFFER Internal CMM Error

21 E_CLI_INVALID_CMM_SLOT Internal CMM Error

22 E_CLI_NO_MSGQ_KEY Internal CMM Error

23 E_CLI_NO_MSGQ Internal CMM Error

24 E_CLI_NO_MSGQ_LOCK Internal CMM Error

25 E_CLI_NO_MSGQ_UNLOCK Internal CMM Error

26 E_CLI_FILE_OPEN_ERROR Internal CMM Error

27 E_CLI_CFG_WRITE_ERROR CMM Config File Error

28 E_IMB_NO_MSGQ Internal CMM Error

29 E_IMB_NO_MSGQ_KEY Internal CMM Error

30 E_IMB_SEND_TIMEOUT Internal CMM Error

31 E_IMB_DRIVER_FAILURE Internal CMM Error

32 E_IMB_REQ_TIMEOUT A blade is not responding to IPMI requests.

33 E_IMB_RECEIVE_TIMEOUT A blade is not responding to IPMI requests.

0 E_SUCCESS Success

Page 107 of the Intel ZT 7102 user manual — 34 E_IMB_COMPCODE_ERROR
Page 107 · click to enlarge
Page 107

RPC

Table 45. Error and Return Codes for the RPC Interface (Sheet 2 of 4)

Code #Error Code String Error Code Description

34 E_IMB_COMPCODE_ERROR

An IPMI request returned with a non successful completion code. User should try the command again.

35 E_IMB_INVALID_PACKET Invalid IPMI response. Blade may be returning invalid data.

36 E_IMB_INVALID_REQUEST Invalid IPMI response. Blade may be returning invalid data.

37 E_IMB_RESPONSE_DATA_OVERFLOW Invalid IPMI response. Blade may be returning invalid data.

38 E_IMB_DATA_COPY_FAILED Internal CMM Error

39 E_IMB_INVALID_EVENT Internal CMM Error

40 E_IMB_OPEN_DEVICE_FAILED Internal CMM Error

41 E_IMB_MMAP_FAILED Internal CMM Error

42 E_IMB_MUNMAP_FAILED Internal CMM Error

43 E_IMB_RESP_LEN_ERROR Invalid IPMI response. Blade may be returning invalid data.

44 E_NEM_SNMPTRAP_ERROR Error setting snmptrap parameters. Retry command

45 E_NEM_SYSTEMHEALTH_ERROR Internal CMM Error

46 E_NEM_GETHEALTH_ERROR Internal CMM Error

47 E_NEM_SNMPENABLE_ERROR Internal CMM Error

48 E_NEM_SENSOR_HEALTH_ERROR Internal CMM Error

49 E_NEM_FILTER_SEL_ERROR Internal CMM Error

50 E_NEM_INITIALIZE_ERROR Internal CMM Error

51 E_NEM_SENSOR_EVENT Internal CMM Error

52 E_NEM_SENSOR_ERROR Internal CMM Error

53 E_NEM_SNMP_PROCESS_EVENT_ERROR Internal CMM Error

54 E_NEM_SNMP_DEST_ADDR_ERROR SNMP Trap address that the user is setting is invalid

55 E_NEM_SNMP_COMMUNITY_STRING_ERROR SNMP Community that user is setting is invalid

56 E_NEM_SNMP_TRAP_VERSION_ERROR SNMP Trap version that the user is setting is invalid

57 E_NEM_SNMP_TRAP_PORT_ERROR SNMP Trap port that the user is setting is invalid

58 E_NEM_SNMP_CFG_ERROR Cannot read SNMP config parameter. Config file may be corrupted.

59 E_NEM_SEND_SNMP_TRAP_ERROR Internal CMM Error

60 E_SFS_INVALID_TRANSACTION Internal CMM Error

61 E_SFS_LOCK_SDR Can't read SDRs. Blade may be busy, try again.

62 E_SFS_ENTITY_ID Internal CMM Error

63 E_SFS_DEVICE_LOCATOR_NULL Internal CMM Error

Page 108 of the Intel ZT 7102 user manual — Table 45. Error and Return Codes for the RPC Interface (Sheet 1 of 4)
Page 108 · click to enlarge
Page 108

Intel® NetStructureTMZT 7102 Chassis Management Module RPC

Table 45. Error and Return Codes for the RPC Interface (Sheet 3 of 4)

Code #Error Code String Error Code Description

64 E_SFS_NO_MEMORY Internal CMM Error

65 E_SFS_UNSUPPORTED_DEVICE Internal CMM Error

66 E_SFS_RESPONSE_LENGTH Internal CMM Error

67 E_SFS_RESPONSE_DATA Internal CMM Error

68 E_SFS_POWER_SUPPLY_FRU Internal CMM Error

69 E_SFS_PATTERN_FOUND Internal CMM Error

70 E_SFS_SEMAPHORE_FAILED Internal CMM Error

71 E_SFS_CALLBACK_NOT_FOUND Internal CMM Error

72 E_SFS_END_OF_DATA Internal CMM Error

73 E_SFS_NO_SEL_ENTRY Internal CMM Error

74 E_SHEM_INTERNAL_ERROR Internal CMM Error

75 E_SHEM_INVALID_DATA_ITEM Not a valid -d parameter

76 E_SHEM_STANDBY_CMM Can't execute this command on the standby CMM

77 E_SNSR_STATUS_UNSUPPORTED Internal CMM Error

78 E_SNSR_UNSUPPORTED Internal CMM Error

79 E_SNSR_CATEGORY Internal CMM Error

80 E_SNSR_NO_MEMORY Internal CMM Error

81 E_SNSR_NOT_FOUND Internal CMM Error

82 E_SNSR_ACTION_UNSUPPORTED Internal CMM Error

83 E_SNSR_NON_FIRMWARE Internal CMM Error

84 E_SNSR_SHARE_CODE Internal CMM Error

85 E_SNSR_LOW_STORAGE Internal CMM Error

86 E_SNSR_EVENT_TYPE Internal CMM Error

87 E_SNSR_INVALID_REQUEST Internal CMM Error

88 E_SNSR_OS_ERROR Internal CMM Error

89 E_SNSR_PROCESSOR_NOT_PRESENT Internal CMM Error

90 E_SNSR_THRESHOLD_UNSUPPORTED The sensor being queried doesn't support a particular threshold

91 E_SNSR_CAPABILITY_UNSUPPORTED Internal CMM Error

92 E_SNSR_SCANNING_DISABLED Internal CMM Error

93 E_SNSR_MAX_RETRIES Internal CMM Error

94 E_SNSR_TRIGGER_TYPE Internal CMM Error

95 E_SNSR_STATE Internal CMM Error

96 E_SNSR_EVENT_DEREGISTER Internal CMM Error

97 E_SNSR_SEL_EVENT_FUNCTION Internal CMM Error

98 E_SNSR_BASE_INDEX Internal CMM Error

99 E_SNSR_PRESENCE_DETECTED Internal CMM Error

Page 109 of the Intel ZT 7102 user manual — 20.2.3 ChassisManagementApi() Threshold Response Format
Page 109 · click to enlarge
Page 109

RPC

Table 45. Error and Return Codes for the RPC Interface (Sheet 4 of 4)

Code #Error Code String Error Code Description

100 E_SNMP_CMD_UNSUPPORTED Internal CMM Error

101 E_SNMP_ERROR Internal CMM Error

102 E_SNSR_VALUE_OUT_OF_RANGE Internal CMM Error

103 E_SNSR_AUTH_ERROR Internal CMM Error

104 E_WP_INITIALIZE_LIBS Internal CMM Error

105 E_WP_CFG_READ_ERROR CMM config file may be corrupted

106 E_WP_CFG_WRITE_ERROR CMM config file may be corrupted

107 E_WP_THRESHOLD_UNSUPPORTED The sensor being queried doesn't support a particular threshold.

108 E_WP_INVALID_TARGET

The sensor doesn't support a "current” value. This happens when querying a current value on a discrete sensor type.

109 E_WP_INVALID_LOCATION Not a valid -l location

110 E_WP_INVALID_DATA_ITEM Not a valid -d parameter

111 E_WP_INVALID_SET_DATA Not a valid -v parameter

112 E_WP_CMD_UNSUPPORTED Not a supported command

113 E_WP_STANDBY_CMM Can't execute this command on the standby CMM.

114 E_WP_I2C_ERROR Internal CMM Error

115 E_FT_SEM_GET_FAILURE Internal CMM Error

116 E_DRONE_NOT_FOUND Internal CMM Error

117 E_INTERNAL_ERROR Internal CMM Error

118 E_BPM_PWR_SUPPLY_NOT_PRESENT Power Supply Not Present Error

119 E_NEM_INTERNAL_FAILURE Internal CMM Error

120 E_WP_CMM_RESET Internal CMM Error

121 E_UPDATE_INPROGRESS Update in Progress

122 E_MSGQ_START Initilization message

20.2.3 ChassisManagementApi() Threshold Response Format

The following table documents the format of ChassisManagementApi() queries that return data of type DATA_TYPE_ALL_THRESHOLDS.

Page 110 of the Intel ZT 7102 user manual — Table 47. String Response Formats (Sheet 1 of 4)
Page 110 · click to enlarge
Page 110

Intel® NetStructureTMZT 7102 Chassis Management Module RPC

Table 46. Threshold Response Formats

Dataitem Return format Example

Data is returned in the THRESHOLDS_ALL structure as defined in cli_client.h. All structure fields are valid.

5.400 Volts

If a particular threshold is not supported, the structure field will contain an empty string.

5.200 Volts

5.100 Volts

4.600 Volts

Each supported and valid field is a null-terminated string.

4.800 Volts

Syntax:

4.900 Volts

[Value] [Units] /n /0

Data is returned in the THRESHOLDS_ALL structure defined in cli_client.h. Only the structure field corresponding to the dataitem requested is valid.

If a particular threshold is not supported, the structure field will contain an empty string.

5.160 Volts

A valid field is a null-terminated string.

Syntax:

[Value] [Units] /n /0

20.2.4 ChassisManagementApi() String Response Format

The following table documents the format of ChassisManagementApi() queries that return data of type DATA_TYPE_STRING.

Table 47. String Response Formats (Sheet 1 of 4)

Dataitem Return format Example

Null-terminated string showing the current value of a sensor.

23.000 Celsius

Syntax:

Null-terminated string showing the orientation of the eth0 Ethernet port:

Syntax:

[front/back] /0

Null-terminated string giving the current CMM fan speed setting:

Syntax:

[0 or 80 or 100] /0

Show 12 more labels / short text on this page
thresholdsall · uppernonrecoverable · uppercritical · uppernoncritical · lowernonrecoverable · lowercritical · lowernoncritical · current · Value [Units] /0 · Ethernet · front · fanspeed
Page 111 of the Intel ZT 7102 user manual — +5 V
Page 111 · click to enlarge
Page 111

RPC

Table 47. String Response Formats (Sheet 2 of 4)

Dataitem Return format Example

Major EventFan Tray 3 Pres Fan Tray Removed

List of human-readable health events. Lines are separated by line feeds with a null-terminator at the end.

Major EventFANTK9 Lower critical going low asserted

"(null)” or "" if there are no healthevents

Major EventFANTK8 Lower critical going low asserted

Refer to Section 11.0, “Health Event Strings” on page 67

Major EventFANTK7 Lower critical going low asserted

Syntax:

[ Critical/Major/Minor ] Event[ Health String ] /n /0
Minor EventBP +12V Upper non-critical going high asserted

List of available dataitems. Lines are separated by line feeds and a null-terminator at the end.

Syntax:

[Dataitem] /n /0

List of available targets. Targets represent the sensor data records (SDRs) for a particular component. Lines are separated by line feeds with a null-terminator at the end.

+1.5 V

+2.5 V

+3.3 V

Syntax:

+5 V

[Sensor Name] /n /0

Null-terminated string containing the user-specified physical location of the CMM, 16 characters maximum.

Syntax:

[Location String] /0

Human readable powerstate information containing the target blade powerstate information. Lines are separated by line feeds with a null-terminator at the end.

Syntax:

Board HEALTHY# signal is asserted

Board is [present or not present] /n

Board has been powered up by the CMM

Board HEALTHY# signal is [asserted or not asserted /n

Board is in active mode.

Board has [not] been powered up by the CMM /n

Board is in [active or offline] mode. /n /0

Show 23 more labels / short text on this page
healthevents · presence · listtargets · listdataitems · health · healthevents · sel · snmpenable · ListDataItems · snmptrapcommunity · snmptrapaddress1 · snmptrapaddress2 · snmptrapaddress3 · snmptrapaddress4 · snmptrapaddress5 · redundancy · powerstate · Brd Temp · ListTargets · location · Server room 3 · Board is present · powerstate
Page 112 of the Intel ZT 7102 user manual — XXX.XXX.XXX.XXX /0
Page 112 · click to enlarge
Page 112

Intel® NetStructureTMZT 7102 Chassis Management Module RPC

Table 47. String Response Formats (Sheet 3 of 4)

Dataitem Return format Example

Human-readable redundancy information containing the current CMM redundancy status. Lines are separated by line feeds with a null-terminator at the end.

Top CMM (CMM 1)Present (active) *

Syntax:

Bottom CMM (CMM 2)Not Present (standby)

Top CMM (CMM 1): [Present or Not Present] ([active or standby]) [* or no star] /n

* = The CMM you are currently logged into.

Bottom CMM (CMM 2): [Present or Not Present] ([active or standby) [* or no star] /n

* = The CMM you are currently logged into. /n /0

Human-readable slot information, containing a list of System slots, Peripheral slots, Busless slots, and Occupied slots. If there are no slots in a particular category, "None” is reported.

Lines are separated by line feeds with a null-terminator at the end. Each colon is followed by one tab (for Peripheral and Busless slots) or two tabs (for System and Occupied slots) and a space-delimited list of slot numbers.

System Slot(s)None

Peripheral Slot(s): 2 3 4 5 6 7 8 13 14 15 16 17 18 19 20 21

Busless (Switch) Slot(s)2 19 20 21

Syntax:

Occupied Slot(s)2 5 21
System Slot(s)[ None or slot numbers ] /n
Peripheral Slot(s)[ None or slot numbers ] /n
Busless (Switch) Slot(s)[ None or slot numbers ] /n
Occupied Slot(s)[ None or slot numbers ] /n /0

Null-terminated string containing a dotted-quad IP address

snmptrapaddress[1..5]

10.10.240.81

Syntax:

XXX.XXX.XXX.XXX /0

Null-terminated string containing the snmptrapcommunity name

Syntax:

[SNMP Trap Community Name String] /0

Null-terminated string showing the SNMP trap port. Syntax: [port number] /0

Null-terminated string showing the version of SNMP traps the CMM is currently set for.

Syntax[v1 or v3] /0
Show 6 more labels / short text on this page
redundancy · slotinfo · snmptrapcommunity · publiccmm · snmptrapport · snmptrapversion
Page 113 of the Intel ZT 7102 user manual — 0 = OK
Page 113 · click to enlarge
Page 113

RPC

Table 47. String Response Formats (Sheet 4 of 4)

Dataitem Return format Example

Human-readable unhealthy blade, cmm and/or chassis information, containing a list of blades, cmms and/or chassis with a health status of Critical, Major, and Minor. If there are no items in a particular category, "None” is reported.

Lines are separated by line feeds with a null-terminator at the end. Each colon is followed by one space and a space-delimited list of blade numbers and the word "chassis” for chassis health conditions.

CriticalNone
MajorNone
Minor8 chassis

Syntax:

Critical[ None or Blade# and/or chassis and/or cmm ] /n
Major[ None or Blade# and/or chassis and/or cmm ] /n
Minor[ None or Blade# and/or chassis and/or cmm ] /n /0

Null-terminated string containing the version of the CMM firmware.

V03.00a

SyntaxVXX.XXX /0

20.2.5 ChassisManagementApi() Integer Response Format

The following table documents the format of ChassisManagementApi() queries that return data of type DATA_TYPE_INT.

Table 48. Integer Response Formats (Sheet 1 of 2)

Dataitem Return format Example

Integer value indicating alarm cutoff status:

0 = alarm not cut off

1 = alarm cut off

alarmtimeout Integer value indicating the alarm cutoff timeout in minutes. 5

Integer value corresponding to the health of the location queried:

0 = OK

Integer value corresponding to the absence or presence of the location queried:

0 = Not present

1 = Present NOTEIf a blade is not present,

ChassisManagementApi() returns E_BLADE_NOT_PRESENT.

Show 8 more labels / short text on this page
unhealthylocations · version · alarmcutoff · health · 1 = Minor · 2 = Major · 3 = Critical · presence
Page 114 of the Intel ZT 7102 user manual — Table 49. FRU Data Items String Response Format (Sheet 1 of 2)
Page 114 · click to enlarge
Page 114

Intel® NetStructureTMZT 7102 Chassis Management Module RPC

Table 48. Integer Response Formats (Sheet 2 of 2)

Dataitem Return format Example

Integer returned is a 1 or 0.

1 = Power supply is not inhibited

0 = Power supply is inhibited

Integer value indicating SNMP status:

20.2.6 FRU String Response Format

Querying an individual FRU field returns a null terminated string with a single line feed.

Querying individual FRU areas returns a null terminated string with the following:

Board Area3 Linefeeds
Product Area2 Linefeeds
Chassis Area2 Linefeeds

Querying the entire FRU (all) will return all of the above areas present in the FRU with the line feeds listed above.

Table 49. FRU Data Items String Response Format (Sheet 1 of 2)

all Null-terminated string containing all FRU information for the location

boardall Null-terminated string containing all board area FRU information for the location

boarddescription Null-terminated string containing the description field in the FRU board area for the location

boardmanufacturer Null-terminated string containing the manufacturer field in the FRU board area for the location

boardpartnumber Null-terminated string containing the part number field in the FRU board area for the location

boardserialnumber Null-terminated string containing the serial number field in the FRU board area for the location

boardmanufacturedatetime Null-terminated string containing the manufacture date and time field in the FRU board area for the location

productall Null-terminated string containing the product area FRU information for the location

productdescription Null-terminated string containing the description field in the FRU product area for the location

productmanufacturer Null-terminated string containing the manufacturer field in the FRU product area for the location

productmodel Null-terminated string containing the model field in the FRU product area for the location

productpartnumber Null-terminated string containing the part number field in the FRU product area for the location

Show 5 more labels / short text on this page
psinhibit · snmpenable · 0 = disabled · 1 = enabled · Data Item Description
Page 115 of the Intel ZT 7102 user manual — 20.4 RPC Usage Examples
Page 115 · click to enlarge
Page 115

RPC

Table 49. FRU Data Items String Response Format (Sheet 2 of 2)

productserialnumber Null-terminated string containing the serial number field in the FRU product area for the location

productrevision Null-terminated string containing the revision field in the FRU product area for the location

productmanufacturedatetime Null-terminated string containing the manufacturer date and time field in the FRU product area for the location

chassisall Null-terminated string containing all chassis area FRU information for the location

chassispartnumber Null-terminated string containing the part number field in the FRU chassis area for the location

chassisserialnumber Null-terminated string containing the serial number field in the FRU chassis area for the location

chassislocation Null-terminated string containing the location field in the FRU chassis area for the location

chassistype Null-terminated string containing the type field in the FRU chassis area for the location.

listdataitems Null-terminated string containing the list of all of the FRU dataitems that can be queried for the FRU target

20.3 RPC Sample Code

Sample code for interfacing with the CMM through RPC is available in the file cli_client.c. The sample code compiles into a command-line executable for use with Linux or a .o file for use with VxWorks. To select the appropriate target, remove the comment from the appropriate #define in the source code.

The sample code first authenticates to the CMM through GetAuthCapability(). When the authentication is successful, the user’s command-line arguments (for Linux) or calling parameters (for VxWorks) are passed to the CMM through ChassisManagementApi(). The return code is then checked and the result is printed to the console.

20.4 RPC Usage Examples

Table 50 presents examples of using RPC calls to get and set fields on the CMM. Data returned by RPC calls are returned in the ppvbuffer and uReturnType parameters to ChassisManagementApi().

Data Item Description

Page 116 of the Intel ZT 7102 user manual — 0 = OK
Page 116 · click to enlarge
Page 116

Intel® NetStructureTMZT 7102 Chassis Management Module RPC

Table 50. RPC Usage Examples (Sheet 1 of 3)

parameters ChassisManagementApi() [out] parameters

pszCMMHostlocalhost
uCmdCodeCMD_GET

Get the chassis temperature.

uReturnTypeDATA_TYPE_STRING
pszLocationChassis
ppvbufferA null-terminated string of the format: Value [Units]
pszTargetTempSensorName
pszDataItemcurrent
pszCMMHostlocalhost
uReturnTypeDATA_TYPE_INT
uCmdCodeCMD_GET

Get the fan tray presence.

ppvbufferInteger value indicating presence
pszLocationfantray1..3
pszTargetNA

0 = Not Present

pszDataItempresence
pszCMMHostlocalhost
uCmdCodeCMD_GET

Get the CPU temperature of blade 5.

uReturnTypeDATA_TYPE_STRING
pszLocationblade5
ppvbufferA null-terminated string of the format: Value [Units]
pszTargetCPUTempSensorName
pszDataItemcurrent
uReturnTypeDATA_TYPE_INT
pszCMMHostlocalhost
ppvbuffer1 = Present

Determine if a certain blade is present.

uCmdCodeCMD_GET
pszLocationblade[1-n]

The call to ChassisManagementApi() returns E_BLADE_NOT_PRESENT if the selected blade is not present.

pszDataItempresence
pszCMMHostlocalhost

Get all thresholds for the +3.3 V sensor on blade 2.

uCmdCodeCMD_GET
uReturnTypeDATA_TYPE_ALL_THRESHOLDS
pszLocationblade2
ppvbufferA THRESHOLDS_ALL structure as defined in cli_client.h
pszTarget3.3vSensorName
pszDataItemThresholdsAll
uReturnTypeDATA_TYPE_INT
pszCMMHostlocalhost
ppvbufferInteger value denoting health state

Get the overall system health.

uCmdCodeCMD_GET

0 = OK

pszLocationsystem
pszDataItemhealth
pszCMMHostlocalhost

Get a list of blades with problems.

uCmdCodeCMD_GET
uReturnTypeDATA_TYPE_STRING
pszLocationsystem
ppvbufferList of all blades with problems
pszDataItemunhealthylocations
uReturnTypeDATA_TYPE_INT
pszCMMHostlocalhost
ppvbufferInteger value denoting health state

Get the temp1 sensor’s health on blade 5.

uCmdCodeCMD_GET

0 = OK

pszLocationblade5
pszTargetTemp1SensorName
pszDataItemhealth
Show 8 more labels / short text on this page
Example ChassisManagementApi() [in] · 1 = Present · 1 = Minor · 2 = Major · 3 = Critical · 1 = Minor · 2 = Major · 3 = Critical
Page 117 of the Intel ZT 7102 user manual — 0 = OK
Page 117 · click to enlarge
Page 117

RPC

Table 50. RPC Usage Examples (Sheet 2 of 3)

parameters ChassisManagementApi() [out] parameters

uReturnTypeDATA_TYPE_INT
pszCMMHostlocalhost
ppvbufferInteger value denoting health state

Get the CMM’s overall health.

uCmdCodeCMD_GET

0 = OK

pszLocationCMM
pszDataItemhealth
uReturnTypeDATA_TYPE_INT
pszCMMHostlocalhost
ppvbufferInteger value denoting health state

Get a blade’s overall health.

0 = OK

pszLocationblade[1..n]
pszDataItemhealth
pszCMMHostlocalhost

Get the version of software on the CMM.

uCmdCodeCMD_GET
uReturnTypeDATA_TYPE_STRING
pszLocationCMM

ppvbuffer: A human-readable null-terminated version string.

pszDataItemversion
pszCMMHostlocalhost
uReturnTypenot used
uCmdCodeCMD_SET

Power off one of the blades.

ppvbuffernot used
pszLocationblade[1-19]

The return code from ChassisManagementApi() indicates success or failure.

pszDataItempowerstate
pszSetDatapoweroff
pszCMMHostlocalhost
uCmdCodeCMD_SET
uReturnTypenot used

Power on one of the blades.

pszLocationblade[1-19]
ppvbuffernot used
pszDataItempowerstate

The return code from ChassisManagementApi() indicates success or failure.

pszSetDatapoweron
pszCMMHostlocalhost
uReturnTypenot used
uCmdCodeCMD_SET

Reset a blade.

ppvbuffernot used
pszLocationblade[1-19]

The return code from ChassisManagementApi() indicates success or failure.

pszDataItempowerstate
pszSetDatareset
pszCMMHostlocalhost

Determine what sensors are on blade 3.

uCmdCodeCMD_GET
uReturnTypeDATA_TYPE_STRING
pszLocationblade3

ppvbuffer: A list of sensor names as defined in the SDR.

pszDataItemListTargets
pszCMMHostlocalhost

Determine what may be queried or set on a blade.

uReturnTypeDATA_TYPE_STRING
uCmdCodeCMD_GET

ppvbuffer: A list of commands to be used as data items.

pszLocationblade3
pszDataItemListDataItems
pszCMMHostlocalhost

Determine what may be queried on the blade4 +3.3 V sensor.

uCmdCodeCMD_GET
uReturnTypeDATA_TYPE_STRING
pszLocationblade4

ppvbuffer: A list of commands to be used as data items.

pszTarget+3.3SensorName
pszDataItemListDataItems
Show 8 more labels / short text on this page
Example ChassisManagementApi() [in] · 1 = Minor · 2 = Major · 3 = Critical · uCmdCode CMD_GET · 1 = Minor · 2 = Major · 3 = Critical
Page 118 of the Intel ZT 7102 user manual — Table 50. RPC Usage Examples (Sheet 3 of 3)
Page 118 · click to enlarge
Page 118

Intel® NetStructureTMZT 7102 Chassis Management Module RPC

Table 50. RPC Usage Examples (Sheet 3 of 3)

parameters ChassisManagementApi() [out] parameters

pszCMMHostlocalhost
uCmdCodeCMD_SET
uReturnTypenot used

Enable the SNMP Traps.

pszLocationchassis
ppvbuffernot used
pszDataItemSNMPEnable

The return code from ChassisManagementApi() indicates success or failure.

pszSetDataenable
pszCMMHostlocalhost
uReturnTypenot used
uCmdCodeCMD_SET

Set the SNMP Target.

ppvbuffernot used
pszLocationchassis

The return code from ChassisManagementApi() indicates success or failure.

pszDataItemSNMPTrapAddress[1-5]
pszSetData134.134.100.34
pszCMMHostlocalhost
uCmdCodeCMD_SET
uReturnTypenot used

Set the SNMP Community.

pszLocationchassis
ppvbuffernot used
pszDataItemSNMPCommunity

The return code from ChassisManagementApi() indicates success or failure.

pszSetDatapublic
pszCMMHostlocalhost
uReturnTypenot used
uCmdCodeCMD_SET

Set the Telco Alarm on.

ppvbuffernot used
pszLocationCMM

The return code from ChassisManagementApi() indicates success or failure.

pszDataItemTelcoAlarm
pszSetData1
pszCMMHostlocalhost
uCmdCodeCMD_SET
uReturnTypenot used

Light Major LED on the CMM.

pszLocationCMM
ppvbuffernot used
pszDataItemMajorLED

The return code from ChassisManagementApi() indicates success or failure.

pszSetData1

Example ChassisManagementApi() [in]

Page 119 of the Intel ZT 7102 user manual — 21.0 Command Logging
Page 119 · click to enlarge
Page 119

21.0 Command Logging

All CMMSET commands from all of the CMM interfaces (CLI, RPC, and SNMP) are logged by the CMM under /var/log. The size of the log file is 8 kbytes. When the command log becomes full, the log file is compressed and archived using gzip, then stored in /home/log. The filenames for the log files will be user.log.N.gz, where N is the number of the log file from 1 to 4. The CMM will keep up to four archives of log files. If the log file becomes full and there are already four existing command log archives, the oldest archive will be deleted to make room for the newest archive.

Command Logging

Page 120 of the Intel ZT 7102 user manual — 21.0 Command Logging
Page 120 · click to enlarge
Page 120

Intel® NetStructureTMZT 7102 Chassis Management Module Command Logging

Page 121 of the Intel ZT 7102 user manual — 22.3 Telco Alarm Connector Sensor Naming
Page 121 · click to enlarge
Page 121

22.0 Telco Alarm Sensors

The faceplate of the CMM contains a µDB15 Telco alarm connector. See Section 2.6, “Face Plate” on page 20 and Section 2.16, “Telco Alarm Signal” on page 34 for more information on the Telco Alarm connector. By default, pins 1 through 4 are used by the CMM to clear major or minor alarms. The current state of pins 1 and 3 inputs are mapped to a GPIO on the CMM and can therefore be reconfigured as discrete sensor inputs.

22.1 Configuring the Telco Alarm Connector Pins

To configure the telco alarm sensors as discrete inputs or to clear events, the following CLI command is used:

cmmset -l cmm -d TelcoInputs -v [sensors or clearEvents]

Where the value (-v) parameter is either:

sensors - Configures the telco alarm inputs as discrete input sensors. Or

clearEvents - Configures the telco alarm inputs to be used to clear telco alarms.

22.2 Obtaining the Configuration of the Telco Alarm Sensor Connector Pins

To retrieve the configuration of the Telco Alarm Sensor pins, use the following CLI command:

cmmget -l cmm -d TelcoInputs

This command will return a value of:

“sensors” - If the telco alarm input pins are being used as discrete sensor inputs.

“clearEvents” - If the telco alarm input pins are being used to clear minor and major alarms.

22.3 Telco Alarm Connector Sensor Naming

The default name of the two telco alarm sensors is TAsensor1 and TAsensor2. These names are used and reported by the various CMM interfaces for the Telco Alarm Sensors. The sensors can be renamed using the following CLI command:

cmmset -l cmm -t TAsensorN -d sensorname -v [NewSensorName]

Where:

N - Is either “1” or “2” for TAsensor1 and TAsensor2, respectively.

NewSensorName - The new name that will be associated with the corresponding sensor.

Telco Alarm Sensors

Page 122 of the Intel ZT 7102 user manual — 22.4 Telco Alarm Sensors and Redundancy
Page 122 · click to enlarge
Page 122

Intel® NetStructureTMZT 7102 Chassis Management Module Telco Alarm Sensors

22.3.1 Sensor Names using SNMP

The telco alarm sensor names that will be shown via SNMP will be those that are defined at CMM startup. If a telco alarm sensor name has been changed after startup, the new name will not be reflected via SNMP until the CMM is restarted.

22.4 Telco Alarm Sensors and Redundancy

In dual CMM systems, the telco alarm sensors are individual to each CMM in the system, and are not synchronized between the two CMMs. SEL entries from sensors on the active CMM will not be synched to the standby CMM.

If it is desired to monitor the same two inputs on both CMMs, the two inputs must be split into four and connected to the telco alarm connectors on both CMMs.

Telco alarm sensor names are synched between the two CMMs. Changing the name of the sensors on the active CMM will cause the same names to be assigned on the standby CMM.

Page 123 of the Intel ZT 7102 user manual — 23.3.1.1 Flash Storage Locations
Page 123 · click to enlarge
Page 123

23.0 Application Hosting

The ZT 7102 allows applications to be hosted locally. This is useful as a method for adding small custom management utilities to the CMM.

23.1 System Details

The CMM runs a customized version of embedded BlueCat* Linux* 4.0 on an Intel® XScale® microarchitecture 80200 processor. Development support for BlueCat Linux is available at:

http://www.lynuxworks.com

23.2 Startup and Shutdown Scripts

The CMM is capable of running user created scripts automatically on boot up or shutdown.This can be accomplished by editing the /etc/rc.d/init.d/userScripts file with a text editor. This is a standard shell file just like /etc/rc.d/init.d/cmm. By default it just echos "Starting user services" and "Shutting down user services". The user can add scripts or what they want to the file. The Ramdisk version of /etc/inittab calls "/etc/rc.d/init.d/userScripts start" right after its starts the cmm software. When you type reboot, it calls "/etc/rc.d/init.d/userScripts stop”.

23.3 System Resources Available to User Applications

Since the CMM has firmware of its own running at all times, user applications must adhere to certain resource and directory constraints to avoid disrupting the CMMs operation. Specifically, restrictions are placed on an application’s consumption of file system storage space, RAM, and interrupts. Exceeding these guidelines may interfere with proper operation of the CMM.

23.3.1 File System Storage Constraints

The following file system locations are available for storage by user applications. Storing files in locations other than those explicitly listed here is not supported.

23.3.1.1 Flash Storage Locations

Applications should not perform excessive amount of flash file I/O at runtime, because this will impair performance of the CMM.

/etc - Useful for storing configuration files. Do not add more than 100 Kbytes to /etc.

/etc/rc.d/init.d - Useful for storing startup scripts. Do not add more than 100 Kbytes to /etc.

/home/scripts - Useful for storing user scripts. Do not add more than 3 Mbytes to /home.

/home - Useful for storing application binaries. Do not add more than 3 Mbytes to /home.

Application Hosting

Page 124 of the Intel ZT 7102 user manual — 23.4 Ram Disk Directory Structure
Page 124 · click to enlarge
Page 124

Intel® NetStructureTMZT 7102 Chassis Management Module Application Hosting

23.3.1.2 RAM-Disk Storage Locations

Due to the constraints of writing to flash memory, larger file operations such as decompressing an archive should be performed on RAM-disk in the following directory:

/usr/local/cmm/temp - Useful for storing temporary files. Applications should make a subdirectory for use with their temporary files. Do not add more than 5 Mbytes to this location.

23.3.2 RAM Constraints

Up to 32 Mbytes of RAM are available for use by user applications. RAM usage at runtime, on average, should not exceed this quantity.

23.3.3 Interrupt Constraints

User applications should not make use of interrupts. All interrupts are reserved for use by the CMM firmware.

23.4 Ram Disk Directory Structure

The following directories are stored on a RAM-disk. These directories store information critical to the CMM and are size constrained. These directories should not be modified in any way.

/usr – Executables including the CMM executables (/usr/local/cmm/bin). Also contains some libraries and temp files.

/lib - Shared library files and drivers

/bin – Linux binary files like ping, mount

/dev – Device driver files

/proc – Special linux area that contains info about memory, drivers, etc.

/root – Empty root user area.

/sbin – Binary files like ifconfig, route

/var – Temp location for log files and other temp files.

/tmp – Empty

Page 125 of the Intel ZT 7102 user manual — 24.0 Busless Backplane Support
Page 125 · click to enlarge
Page 125

24.0 Busless Backplane Support

The ZT 7102 supports busless PICMG* 2.16 backplanes. Busless backplanes are PICMG 2.16 backplanes that do not have the CompactPCI* bus routed or enabled. When the CMM is inserted into a busless backplane, the ZT7102 does not perform a check for system or peripheral slots, and powers up the boards in any slot regardless. Boards used in this type of chassis should be system master, or drone mode enabled boards. Special care should be taken to not use peripheral only boards in such a chassis as these boards rely on a system master and CompactPCI bus to operate properly.

Busless Backplane Support

Page 126 of the Intel ZT 7102 user manual — 24.0 Busless Backplane Support
Page 126 · click to enlarge
Page 126

Intel® NetStructureTMZT 7102 Chassis Management Module Busless Backplane Support

Page 127 of the Intel ZT 7102 user manual — 25.2 Update Process Architecture
Page 127 · click to enlarge
Page 127

25.0 Updating Software

When new CMM updates are available, they are packaged in a zip file and posted to the Intel web site located at:

http://www.intel.com/design/network/products/cbp/zt7102.htm

Please follow the instructions provided with the software update package to perform the update

The CMM is capable of having its firmware and critical system files updated when new update packages become available. The update process allows these updates to occur over the wire without losing the active cmm in a redundant configuration.

25.1 Key Features of the Firmware Update Process

  • Updates can be done remotely over the front or back Ethernet ports on the CMM
  • Current CMM configuration data is preserved across the update
  • Critical CMM data such as the SEL and command history is preserved across an update
  • Redundant CMMs can be updated without interrupting management of the chassis
  • Update files are verified and checked for corruption
  • Update components have associated version numbers
  • Update events are logged to the SEL
  • Updates can be triggered using the CLI
  • Update packages can be located locally on the CMM, or pulled from a mounted NFS or remote FTP server

25.2 Update Process Architecture

The update process consists of the following components:

  • User Client - The client is used to trigger the update process, and can be located anywhere on the network.
  • Update Package - The update package contains the new software components and other files necessary for the update. The update package can be pulled from a remote server or pushed locally onto the CMM.
  • CMM Update Request Handler - The update request handler is CMM software that processes incoming update requests from and responses to the various interfaces provided by the CMM.
  • CMM Update Script - The update script is stored on the CMM and is used to process the contents of the update package and perform the update.
  • Update Package Server (Optional) - The update package server can be used to store update packages remotely from the CMM. This can be an FTP or NFS server.

Updating Software

Page 128 of the Intel ZT 7102 user manual — Table 52. Contents of the Update Package (Sheet 1 of 2)
Page 128 · click to enlarge
Page 128

Intel® NetStructureTMZT 7102 Chassis Management Module Updating Software

25.3 Critical Software Update Files and Directories

The following table is a list of files and directories important to the software update process.

Table 51. List of Critical Software Update Files and Directories

File or Directory NameDescription:

/usr/local/cmm/temp Mount point for ramdisk

Directory into which the update package is copied and unzipped. The update process will delete and recreate this directory. If it is desired to copy the update package to the CMM before updating, then put the package in /usr/local/cmm/temp/update. NOTE: Do NOT place the update files into the

/usr/local/cmm/temp/update/package directory. The update process uses this directory and will erase and overwrite files placed here.

/usr/local/cmm/temp/update/etc Backup copy of /etc is located here

[package file].zip Zip file containing update package files

[package file].md5 MD5 checksum of the [package file].zip file

/etc/versions At the end of an update, this file contains a list of the package version, and each component version

The update process will move the "old" /etc/versions file by appending a file extension to it which is the package version string - i.e., .. /etc/versions.V00.30a

/etc/versions.

These optional scripts are supplied by the user. The update process will execute them just prior to shutting down the cmm applications. The primary function of these scripts is to allow the user a method of shutting down any user process which are using the flash file systems.

These optional scripts are supplied by the user. The update process will execute these scripts just before processing the save list - which copies files and directories from /usr/local/cmm/temp/update/etc to /etc

/home/update/backup If the update direction is "backward", then files and directories that are priority 2 will be copied here instead of /etc

/usr/local/cmm/temp/update/update.log Log file to which output is sent while the update process is operating - this is on a ramdisk.

/etc/cmm/update.log The log file is copied when the update process completes successfully

25.4 Update Package

The update package will be distributed by Intel and may contain the following components:

Table 52. Contents of the Update Package (Sheet 1 of 2)

CMM_RB.bin Redboot image to be stored in flash

CMM_FPGA.bin FPGA image

CMM_FFS.bin /etc image

Show 4 more labels / short text on this page
/usr/local/cmm/temp/update/package · /home/update/scripts/K* · /home/update/scripts/S* · File Name Description
Page 129 of the Intel ZT 7102 user manual — 25.4.2 Update Firmware Package Version
Page 129 · click to enlarge
Page 129

Table 52. Contents of the Update Package (Sheet 2 of 2)

CMM_OS.bin OS image

README Text file containing release notes for the update package

Update_Metadata File containing info on the update package and how it should be installed on the CMM

Utilities Sub-directory containing any utilities that might be required for the install

validationfile File containing MD5 check sums for the files and scripts present in the update package

saveList List of configuration files in /etc to be preserved across software updates

Other Other components such as FRU files that may be necessary for the update

version_history List of all versions of firmware available for the platform in sequential order, with the newest versions at the end of the list.

ZT7102.MIB MIB file for SNMP.

The update package can be placed locally on the CMM in the /usr/local/cmm/temp directory, or it can reside on a server on the network.

The files and directories that make up the Update Package are packaged and delivered as a zip file. Associated with the zip file is a file containing the md5 sum of the zip file. For example:

[PackageFileName].zip file containing all files and subdirectories of the update package

[PackageFileName].md5 file containing md5 checksum of PackageFileName.zip

Arguments for the location of the update package will be given in the CLI command. It is here that you can point to a remote server, or to a local directory. The update script will then remove the /usr/local/cmm/temp/update/package directory and recreate it with the new package files.

If the package fails to copy or transfer to /usr/local/cmm/temp/update/package, then the update process will terminate.

25.4.1 Update Package File Validation

The first level of update package validation is checking that the md5sum of the zip file matches the md5sum in the [PackageFileName].md5 file of the update package.

Update packages are validated during the update process by computing the md5sum of each file and comparing against the check sums stored in the check sums stored in the validation_file included with the update package.

The update package is also checked to ensure it is valid for the platform that it is being used on. For example, an update package with firmware for a CPCI CMM will not work on an ATCA CMM.

25.4.2 Update Firmware Package Version

The firmware update package has a firmware version associated with the entire package. This firmware version is the same version that can be retrieved using the CLI command:

cmmget -l cmm -d version

Updating Software · File Name Description

Page 130 of the Intel ZT 7102 user manual — Table 53. saveList Items and Their Priorities (Sheet 1 of 2)
Page 130 · click to enlarge
Page 130

Intel® NetStructureTMZT 7102 Chassis Management Module Updating Software

To determine if the update is a new, old or same version, the update package will contain a version_history file which contains a list of all software builds that have occurred, listed in sequential order. Newer builds are at the bottom of the list.

25.4.3 Component Versioning

The components contained in the update package will contain versioning information which will allow the update process to ensure the updated components installed on the CMM are all compatible at the end of an update and match those contained in the update package.

If an update package contains a component version that is already installed on the CMM, then that component will not be updated. A method is also provided to force all components to update regardless of the version installed.

Version info for files currently installed on the CMM will be able to be obtained through the various interfaces and is stored in the /etc/cmm/versions file. Version info for the files in the update package will also be made available.

The CMM checks the md5sum of /etc/versions during boot. In the event that the checksum fails, the CMM applications will fail to start and a message will appear on the console as follows “Startup of CMM applications has terminated due to detection of an inconsistent software load.” This functionality exists to prevent a CMM with an incorrect /etc/versions file, which may have occurred during an incomplete update, from synchronizing incorrectly with the other CMM.

25.5 saveList and Data Preservation

The update process will preserve user configuration data as well as critical system configuration information across updates. These files are located in the /etc directory. The list of files or directories to be preserved across updates is contained in the software update package and is called SaveList. Each entry in the saveList will contain a directory or file to be saved as well as a priority assigned to it. Priority for the file can be either a 1 or a 2, and is used to determine if certain files or directories should be saved when updating to an earlier firmware version.

Priority 1 is assigned to files or directories that should be saved in all cases of an update, including going forward or backward in firmware version. Priority 1 files are considered files critical to the CMM operation and access to the CMM, such as Ethernet configuration.

Priority 2 is assigned to files or directories which should not be saved if an update is being performed to an earlier version of firmware.

During an update, the CMM will copy over the current files in /etc to ram disk in /usr/local/cmm/temp/update/etc. The CMM then uses the saveList file to determine which configuration files or directories to copy back into the new /etc partition. When updating to a previous version of firmware, the CMM makes a backup of any files designated priority 2 in the save list to flash in the /home/update/backup/etc directory.

Table 53. saveList Items and Their Priorities (Sheet 1 of 2)

/etc/*.cfg 2

/etc/*.ini 2

/etc/cmm/*.ent 2

File Priority

Page 131 of the Intel ZT 7102 user manual — 25.7 Update_Metadata File
Page 131 · click to enlarge
Page 131

Table 53. saveList Items and Their Priorities (Sheet 2 of 2)

/etc/snmp*.conf 1

25.6 Update Mode

To perform the update, the CMM will enter an update mode to prevent interference from other processes that may write to the flash and to unmount the JFFS2 drives that may need to be repartitioned.

In the update mode, all CMM applications will be stopped. Any user defined processes that are running must also be stopped. Hooks in the update process will be provided to allow these processes to be stopped by calling user scripts located in /home/update/scripts/ if they exist. The update process will execute any scripts that match the following pattern: /home/update/scripts/K*. Scripts will be execute in alpha-numeric sort order. Getting a directory listing using the “ls” command will display the order the scripts will run. User scripts should follow the convention of returning a “0” if successful and a non-zero for failure. The update process will not fail if a script returns a failure, however, the update process will fail if the flash drives cannot be unmounted when necessary.

Before unmounting the JFFS2 drives (/etc and /home), /etc will be copied to ram disk /usr/local/cmm/temp/update/etc to retain user and system configuration information.

Because all CMM applications are stopped, systems running with redundant CMMs will lose redundancy during the firmware update process.

25.7 Update_Metadata File

The Update_Metadata file included in the update package is used by the update process to determine the platform, firmware package version, files, sequence, update method, location, and any other data required to update the individual components in the update package.

Show 12 more labels / short text on this page
Updating Software · File Priority · /etc/passwd 1 · /etc/shadow 1 · /etc/cmm/sel_* 1 · /etc/cmm/cmm_sel 1 · /etc/ifcfg-eth* 1 · /etc/HOSTNAME 1 · /etc/ftp* 1 · /etc/group 1 · /etc/profile 1 · /etc/versions* 1
Page 132 of the Intel ZT 7102 user manual — 25.8.2 Updating to an Older Synchronization Version
Page 132 · click to enlarge
Page 132

Intel® NetStructureTMZT 7102 Chassis Management Module Updating Software

25.8 Synchronization

Following a firmware update to the standby CMM in a redundant CMM, some level of synchronization will occur. The firmware contains an internal synchronization version which is used to determine what level of synchronization occurs following an update. The internal synchronization number will increment each time a firmware package is released.

Following a firmware update, the CMM with the newest synchronization version will become or remain the active CMM. If the synchronization version is the same after an update, a full synchronization occurs.

The following table describes the behavior following an update to a different synch code version.

Table 54. Synchronization Behavior for Differing Synch Versions

Local Synch Version > Other

Local Synch Version < Other Synch

Synch to StandbyBoard Power States, SEL, SNMP trap addresses, Password

Local CMM is Active Synch to Standby: Board Power States

Synch from ActiveBoard Power States, SEL, SNMP trap addresses, Password

Local CMM is Standby

Synch from Active: Board Power States.

Board power states are synchronized in all cases (synch versions equal or not equal).

The synchronization process does not synchronize the alarms (SEL) when the synch versions are not equal. SEL files are saved by the update process. During an update to an earlier version of a redundant setup, alarms received while the Standby is being updated won't be synchronized.

25.8.1 Updating to a Newer Synchronization Version

Following an update on the standby CMM to firmware that has a newer synchronization version than the active CMM, the active CMM will synchronize critical information, such as board power states, the SEL, SNMP trap addresses and configuration, and password files. Once synchronization completes, the newly updated CMM will then become the active CMM because it has a newer synchronization version.

25.8.2 Updating to an Older Synchronization Version

Following an update on the standby CMM to firmware that has an older synchronization version than the active CMM, no synchronization will occur and the newly updated CMM will remain as standby because it has an older synchronization version.

Synch Version · Version

Page 133 of the Intel ZT 7102 user manual — 25.11 CLI Support
Page 133 · click to enlarge
Page 133

25.8.3 Updating to the Same Synchronization Version

Following an update on the standby CMM to firmware that has the same synchronization version as the active CMM, a full synchronization will occur upon completion of the update (as if a new CMM has been inserted into the chassis). The newly updated CMM will remain as the standby CMM following synchronization.

25.9 Single CMM System

When updating CMMs in a system that only contains a single CMM, once the CMM enters the update mode, any components in that system the CMM manages power to may power down because the CMM applications are stopped. Consult your system and board documentation to determine the effect of updating or removing the CMM from the system.

25.10 Redundant CMM Systems

In systems with redundant CMMs, the update should be triggered on the standby CMM. An update cannot occur on the active CMM.

Once the CMM enters the update mode, the chassis will lose redundancy for the duration of the update process.

25.11 CLI Support

The CLI will support a command for an update request. The syntax of the command is as follows:

cmmset -l cmm -d update -v “[Update Package path and filename] [force] [overwrite] [ftp:server:user:password]”

Where:

Update Package path and filename - The path and file name of the update package file without the .zip or .md5 extension. For example: “builds/build105b/CMM_P00.105b”

force - Optional argument that causes all components to update regardless of version. This option cause the environment variable FORCE_UPDATE to be set to TRUE.

overwrite - Optional argument that prevents data in the saveList from being preserved. Also, data restore user scripts will not be executed. This option cause the environment variable FORCE_OVERWRITE to be set to TRUE.

The following arguments are used if the update package is located on a remote FTP server. If ftp is supplied as an argument, server and user are also required. Password is optional. If password is not supplied, then ftp will prompt for a password.

ftp - Optional argument used to indicate that the update package resides on a remote ftp server. If this argument is given, the arguments for server, user, and password must also be given.

server - Optional argument that is the name or IP address of a remote ftp server containing the firmware update package.

Updating Software

Page 134 of the Intel ZT 7102 user manual — 25.12.1 Update Mode User Scripts
Page 134 · click to enlarge
Page 134

Intel® NetStructureTMZT 7102 Chassis Management Module Updating Software

user and password - Optional argument that is the username and password for the FTP server.

The command returns a 0 if the update request is successful, and non-zero if an error occurs.

25.12 Hooks for User Scripts

The update process provides hooks for user scripts in two places during the update process. User scripts should follow the convention of returning a "0" if successful and a non-zero for failure. The user scripts will be invoked as a forked sub-shell.

25.12.1 Update Mode User Scripts

Entering update mode requires that all JFFS2 drives be unmounted, which requires that all processes using these drives be stopped. Prior to entering update mode, the update process will call user scripts located in /home/update/scripts/ if they exist. The update process will execute any scripts that match the following pattern: /home/update/scripts/K*. No arguments are passed to these scripts. The update process will not fail if a script returns a failure, however, the update process will fail if the flash drives cannot be unmounted when necessary. A message indicating if the script was successful or failed will be output to the terminal. See Section 25.6, “Update Mode” on page 131 for more information on the Update Mode.

25.12.2 Data Restore User Scripts.

The update process will also execute user scripts following the update of the new /etc file system to flash. The update process will execute any user scripts that match the following pattern: /home/update/scripts/S*. Arguments will be passed that the scripts can use. These arguments are:

arg1 = Update Component Name["BlueCat", "etc_jffs", "RedBoot", "fpga"]
arg2 = Update Direction["forward", "backward", "same"]

arg3 = Installed Package Version: i.e., "P00.105b". This is the version of the software that is currently installed on the cmm.

arg4 = Update Package Version: i.e., "P00.111a". This is the version of the update package software.

The update script will print a message to the terminal indicating whether the script was successful or failed. Currently, the failure of one of these scripts does not cause the overall update process to fail.

These scripts can be used to perform any user updates that need to coincide with the newly installed version.

Page 135 of the Intel ZT 7102 user manual — 25.12.3 Example Task - Replace /home/scripts/myScript with a newer version if updating forward or an older version if updating backward
Page 135 · click to enlarge
Page 135

25.12.3 Example Task - Replace /home/scripts/myScript with a newer version if updating forward or an older version if updating backward

Example update scenario:

  • There are three CMM builds - call them A, B, and C. The CMM is currently installed with build B. Build A is older than B and C is newer.
  • If the CMM is updated to build C, then the user script /home/scripts/myScript needs to be updated to a newer version.
  • Similarly, if the CMM is reverted to build A, then the user script /home/scripts/myScript needs to be replaced with an older version.
  • The old version of myScript is placed on the CMM as: /home/stagingarea/myScript.old
  • The new version of myScript is placed on the CMM as: /home/stagingarea/myScript.new
  • The Data Restore User Script written to manage /home/scripts/myScript is placed on the CMM as: /home/update/scripts/S10updateMyScript

A simple example of the S10updateMyScript could look like the following:

if [ "$direction" = "forward" ] ; then cp /home/stagingarea/myScript.new /home/scripts/myScript elif [ "$direction" = "backward" ] ; then cp /home/stagingarea/myScript.old /home/scripts/myScript fi

When the update process executes, and the Data Restore User Scripts are executed (during the update of the /etc partition), then the script S10updateMyScript will be executed and /home/script/myScript will be updated accordingly.

Variation on the above example:

  • In this case, the different versions of myScript are put on the CMM (by the user) as:

— /home/stagingarea/myScript.A

— /home/stagingarea/myScript.B

— /home/stagingarea/myScript.C

Another example of S10updateMyScript:

Show 5 more labels / short text on this page
Updating Software · #!/bin/bash · direction=$2 · exit $? · #!/bin/bash
Page 136 of the Intel ZT 7102 user manual — 25.13 Update Process
Page 136 · click to enlarge
Page 136

Intel® NetStructureTMZT 7102 Chassis Management Module Updating Software

newversion=$4 cp /home/stagingarea/myScript.$newversion /home/scripts/myScript exit $?

25.13 Update Process

1. Client initiates an update request via CLI command
2. CMM validates the update request

— CMM is not already doing an update

— In a redundant configuration, the CMM must be standby

— In a redundant configuration, redundancy must be "active"

— CMM is not currently synchronizing

— Enough space is present in ramdisk and flash for the update

3. If update request is valid then
4. Else
5. If FTP arguments supplied then

— Retrieve package files (.zip, .md5) from FTP server

— Exit if error occurs

6. Else

— Copy package files (.zip, .md5) to package directory on ramdisk

— Exit if error occurs

7. Validate that .zip file matches checksum in .md5 file

— Exit if no match

8. Unzip the .zip file in the package directory on ramdisk
9. Validate that all files in the unzipped package match the md5 checksum in the validationFile.

— Exit if any files fail

10. Validate that the package matches the CMM platform ("cpci" or "atca")

— a.Exit if mismatch

11. Transition to Update Mode

— Call any user supplied scripts in /home/update/scripts/K*

— Shutdown CMM apps (/etc/rc.d/init.d/cmm stop)

— Copy /etc to /usr/local/cmm/temp/update/etc

— Unmount /etc and /home

— Exit if any of these filesystems cannot be unmounted

— Continue · — Exit · (/usr/local/cmm/temp/update/package)

Page 137 of the Intel ZT 7102 user manual — 25.16 Update Process Sensor and SEL Events
Page 137 · click to enlarge
Page 137
12. Update Components (listed in UpdateMetadata file)

— If a component update fails

Stop updating components Attempt to remount /etc and /home Exit the update process, but do not reboot

— If the component is "etc_jffs" then

Remount /etc and /home Call any user supplied scripts in /home/update/scripts/S* Process saveList - copying files and directories from /usr/local/cmm/temp/update/etc to /etc

13. If the process has been successful so far then

— Remount /etc and /home

— Update the /etc/versions file - backing up the old one as "/etc/versions."

— Copy the update.log file from ramdisk to /etc/cmm/update/update.log

25.14 Update Process Status and Logging

During the update process, status is sent to stdout as it executes. Output will also be appended to the file /usr/local/cmm/temp/update/update.log. This file will be copied to /etc/cmm/update.log at the completion of the update process.

Status output will be of the format:

MM/DD/YY HH:MM:SS [process[pid]]: [Message String]

25.15 DEBUG_UPDATE Variable

Setting the environment variable DEBUG_UPDATE prior to starting an update will print out additional debug level output to the user including all files that are copied during the update process. To set the DEBUG_UPDATE variable type the following in the CLI:

25.16 Update Process Sensor and SEL Events

Once the CMM enters the update mode in which no CMM processes are active, events cannot be entered into the SEL directly. While in this mode, the CMM will enter events into the eeprom. Once the system reboots into the OS, the CMM will log the events from the eeprom into the SEL.

Updating Software · — Reboot CMM · export DEBUG_UPDATE=1

Page 138 of the Intel ZT 7102 user manual — 25.17.2 Update Procedure
Page 138 · click to enlarge
Page 138

Intel® NetStructureTMZT 7102 Chassis Management Module Updating Software

25.17 RedBoot Update Process

The firmware can also be updated through Redboot. This update is done at a pre-OS level, meaning that the update is executed before the OS loads. This method requires updating over TFTP through the eth0 Ethernet port and must be done locally. A separate update package is needed if this method is used. The following instructions are included with the update package.

25.17.1 Required Setup

To update the flash on the CMM using the Redboot method, the following setup is required:

1. A host computer running Microsoft* Windows XP, 2000 or NT4.0 operating systems
2. The above computer should be configured with a static IP address of 192.168.100.20 and a subnet mask of 255.255.255.0
3. The above computer should be on the same subnet as the CMM or connected directly.
4. It is highly recommended that the subnet be isolated. The only two network entities on the subnet should be the CMM and the Windows computer.

25.17.2 Update Procedure

Read through the following steps completely before starting the update.

1. Extract the contents of the zip file into a folder (e.g. "C:\CMM\") on the host PC.
2. Open a DOS Command Line Prompt on the Windows PC and change directory to the above folder (e.g. C:\CMM)
3. To execute the update, the CMM needs to be reset using the reset button on the faceplate while simultaneously executing update_cmm.bat on the host with the following options:

a. The MAC address of the connected interface on the CMM is the first command line param-

eter. To find this out, use the command ifconfig eth0 on the CMM CLI to find out the MAC address of eth0.

b. A second argument ,"FFS", must be used when upgrading/downgrading to a different

version. Note that this will reset the passwords, IP addresses and other custom Linux envi- ronment settings to factory defaults and clear the event log entries.So far the command line on the host should look like this:

c. By default, the update script assumes that the host computer and the CMM are on the network

192.168.100.x. If your host computer is on a different network, provide another command line argument to the update_cmm batch file. This argument should be an unused IP address on the same network the host computer is on. For example:

update_cmm 00-a0-b7-d8-d8-5d FFS 192.168.100.50

After executing the batch file, follow the instructions as prompted by the batch file for a successful update.

update_cmm 00-a0-b7-d8-d8-5d FFS

Page 139 of the Intel ZT 7102 user manual — Table 55. Example CLI Commands (Sheet 1 of 2)
Page 139 · click to enlarge
Page 139

Appendix D Example CLI Commands

The following table shows examples of most CLI operations.

Table 55. Example CLI Commands (Sheet 1 of 2)

Use Case CLI Command Return

Get current chassis temperature for “Temp Snsr 1”.

cmmget –l chassis –t “Temp Snsr 1”

Current Temperature for “Temp Sensr 1” on chassis.

Get fan tray 1 presence. cmmget –l fantray1 –d presence Fantray1 is present.

Fantray1 is not present.

Get the baseboard temperature of blade 5 when the sensor is named “ambient temp”.

cmmget –l blade5 –t “ambient temp”–d current Current Temperature of “ambient temp” on blade 15.

Find out if blade 15 is present. cmmget –l blade15 –d presence Blade15 is present.

Blade15 is not present.

Returns thresholds for upper non-recoverable, upper critical, upper non-critical, lower non-critical, lower critical, and lower non-recoverable.

Get all thresholds for the +3.3 V sensor on blade 2.

cmmget –l blade2 –t “+3.3V” –d thresholdsall

Get the overall system health. cmmget –l system –d health Indicates if the entire system is healthy, or has health events.

Get a list of blades with problems cmmget –l system –d unhealthylocations List of locations with active health events.

Indicates if the CMM is healthy or if there are active health events on the CMM.

Get the CMM’s overall health. cmmget –l cmm –d health

Display the SEL of the CMM cmmget –l cmm –d sel Displays a list of SEL entries (if any) for the CMM.

Display the SEL of blade19. cmmget –l blade19 –d sel Displays a list of SEL entries (if any) for blade 19.

Get the version of firmware on the CMM cmmget –l cmm –d version Displays the version of firmware currently installed on the CMM.

Power off blade 19. cmmset -l blade19 –d powerstate –v poweroff Displays a success or failure message.

Power on blade 20. cmmset –l blade20 –d powerstate –v poweron Displays a success or failure message.

Reset blade 3. cmmset –l blade3–d powerstate -v reset Displays a success or failure message.

Get all of the chassis FRU information. cmmget –l chassis -t fru -d all Displays a list of all of the FRU information from the chassis.

Get all fantray2 FRU information cmmget –l fantray2 –t fru –d all Displays a list of all of the FRU information from the CMM.

Example CLI Commands · –d current

Page 140 of the Intel ZT 7102 user manual — Table 55. Example CLI Commands (Sheet 2 of 2)
Page 140 · click to enlarge
Page 140

Intel® NetStructureTMZT 7102 Chassis Management Module Example CLI Commands

Table 55. Example CLI Commands (Sheet 2 of 2)

Use Case CLI Command Return

Get a blade’s FRU information cmmget –l blade[1-19] –d fru A list of FRU information.

Find out what sensors are on blade 3. cmmget –l blade3 –d listtargets A list of sensor names as defined in their SDRs on blade 3.

List the data items that can be queried or set on blade 4.

cmmget –l blade4 –d listdataitems A list of dataitems for blade 4.

Find out what can be queried on blade4’s +3. 3V sensor.

cmmget –l blade4 –t “+3.3V” –d listdataitems A list of commands to be used as dataitems for the +3.3V.

Enable SNMP Traps cmmset –l cmm –d snmpenable –v enable Success or failure

Set SNMP Trap Address1

cmmset –l cmm –d snmptrapaddress1 –v 134.134.100.34 Success or failure

Set SNMP Community cmmset –l cmm –d snmpcommunity –v public Success or failure

Page 141 of the Intel ZT 7102 user manual — E.4 Intel ® IOP310 Processor Chipset
Page 141 · click to enlarge
Page 141

Appendix E Datasheet Reference

This appendix provides links to datasheets, standards, and specifications for the technology designed into the CMM.

E.1 Intel ® CompactPCI* Product Information

Information, collateral, and software updates for all CompactPCI-compatible Intel products can be found at:

http://developer.intel.com/design/network/products/cbp/linecard.htm

E.2 CompactPCI

Current CompactPCI Specifications can be purchased from PICMG* for a nominal fee. Short form specifications in Adobe Acrobat format (PDF) are also available on PICMG's website at:

http://www.PICMG.org/gcompactPCI.htm

E.3 IPMI

The Intelligent Platform Management Initiative is described and current specifications can be found at:

http://developer.intel.com/design/servers/ipmi/spec.htm

E.4 Intel ® IOP310 Processor Chipset

For more information about the Intel® IOP310 Processor Chipset, see the following Web site:

http://developer.intel.com/design/iio/docs/iop310.htm

Datasheet Reference

Page 142 of the Intel ZT 7102 user manual — Appendix E Datasheet Reference
Page 142 · click to enlarge
Page 142

Intel® NetStructureTMZT 7102 Chassis Management Module Datasheet Reference

Page 143 of the Intel ZT 7102 user manual — F.1.2 For the Americas
Page 143 · click to enlarge
Page 143

Appendix F Warranty Information

F.1 Intel ® NetStructure™ Compute Boards & Platform Products Limited Warranty

Intel warrants to the original owner that the product delivered in this package will be free from defects in material and workmanship for two (2) year(s) following the latter of: (i) the date of purchase only if you register by returning the registration card as indicated thereon with proof of purchase; or (ii) the date of manufacture; or (iii) the registration date if by electronic means provided such registration occurs within 30 days from purchase. This warranty does not cover the product if it is damaged in the process of being installed. Intel recommends that you have the company from whom you purchased this product install the product.

THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, ANY WARRANTY OF INFRINGEMENT OF ANY OTHER PARTY'S INTELLECTUAL PROPERTY RIGHTS, OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL, SPECIFICATION OR SAMPLE.

This warranty does not cover replacement of products damaged by abuse, accident, misuse, neglect, alteration, repair, disaster, improper installation or improper testing. If the product is found to be otherwise defective, Intel, at its option, will replace or repair the product at no charge except as set forth below, provided that you deliver the product along with a return material authorization (RMA) number (see below) either to the company from whom you purchased it or to Intel. If you ship the product, you must assume the risk of damage or loss in transit. You must use the original container (or the equivalent) and pay the shipping charge. Intel may replace or repair the product with either a new or reconditioned product, and the returned product becomes Intel's property. Intel warrants the repaired or replaced product to be free from defects in material and workmanship for a period of the greater of: (i) ninety (90) days from the return shipping date; or (ii) the period of time remaining on the original two (2) year warranty.

This warranty gives you specific legal rights and you may have other rights which vary from state to state. All parts or components contained in this product are covered by Intel's limited warranty for this product. The product may contain fully tested, recycled parts, warranted as if new.

F.1.1 Returning a Defective Product (RMA)

Before returning any product, contact an Intel Customer Support Group to obtain either a Direct

Return Authorization (DRA) or Return Material Authorization (RMA). Return Material

Authorizations are only available for products purchased within 30 days.

Return contact information by geography:

F.1.2 For the Americas

Return Material Authorization (RMA) credit requests e-mail address: requests.rma@intel.com

Direct Return Authorization (DRA) repair requests e-mail address: uspss.repair@intel.com

Warranty Information

Page 144 of the Intel ZT 7102 user manual — F.1.4 For APAC
Page 144 · click to enlarge
Page 144

Intel® NetStructureTMZT 7102 Chassis Management Module Warranty Information

DRA on-line formhttp://support.intel.com/support/motherboards/draform.htm
Intel Business Link (IBL)http://www.intel.com/ibl

Telephone No.: 1-800-INTEL4U or 480-554-4904

Office HoursMonday - Friday 0700-1700 MST Winter / PST Summer

F.1.3 For EMEA

Return Material Authorization (RMA) e-mail address - emea.fs@intel.com

Direct Return Authorization (DRA) for repair requests e-mail address: emea.fs@intel.com

Intel Business Link (IBL)http://www.intel.com/ibl

Telephone No.: 00 44 1793 403063

Fax No.: 00 44 1793 403109

Office HoursMonday - Friday 0900-1700 UK time

F.1.4 For APAC

RMA/DRA requests email addressapac.rma.front-end@ intel.com

Telephone No.: 604-859-3111 or 604-859-3325

Fax No.: 604-859-3324

Office HoursMonday - Friday 0800-1700 Malaysia time

Return Material Authorization (RMA) requests e-mail address: rma.center.jpss@intel.com

Telephone No.: 81-298-47-0993 or 81-298-47-5417

Fax No.: 81-298-47-4264

Direct Return Authorization (DRA) for repair requests, contact the JPSS Repair center.

E-mail addresssugiyamakx@ intel.co .jp

Telephone No.: 81-298-47-8920

Fax No.: 81-298-47-5468

Office HoursMonday - Friday 0830-1730 Japan time

If the Customer Support Group verifies that the product is defective, they will have the Direct Return Authorization/Return Material Authorization Department issue you a DRA/RMA number to place on the outer package of the product. Intel cannot accept any product without a DRA/RMA number on the package. Limitation of Liability and Remedies

INTEL SHALL HAVE NO LIABILITY FOR ANY INDIRECT OR SPECULATIVE DAMAGES (INCLUDING, WITHOUT LIMITING THE FOREGOING, CONSEQUENTIAL, INCIDENTAL AND SPECIAL DAMAGES) ARISING FROM THE USE OF OR INABILITY TO USE THIS

Page 145 of the Intel ZT 7102 user manual — F.1.3 For EMEA
Page 145 · click to enlarge
Page 145

PRODUCT, WHETHER ARISING OUT OF CONTRACT, NEGLIGENCE, TORT, OR UNDER ANY WARRANTY, OR FOR INFRINGEMENT OF ANY OTHER PARTY'S INTELLECTUAL PROPERTY RIGHTS, IRRESPECTIVE OF WHETHER INTEL HAS ADVANCE NOTICE OF THE POSSIBILITY OF ANY SUCH DAMAGES, INCLUDING, BUT NOT LIMITED TO LOSS OF USE, BUSINESS INTERRUPTIONS, AND LOSS OF PROFITS. NOTWITHSTANDING THE FOREGOING, INTEL'S TOTAL LIABILITY FOR ALL CLAIMS UNDER THIS AGREEMENT SHALL NOT EXCEED THE PRICE PAID FOR THE PRODUCT. THESE LIMITATIONS ON POTENTIAL LIABILITIES WERE AN ESSENTIAL ELEMENT IN SETTING THE PRODUCT PRICE. INTEL NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME FOR IT ANY OTHER LIABILITIES.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you.

Warranty Information

Page 146 of the Intel ZT 7102 user manual — F.1.3 For EMEA
Page 146 · click to enlarge
Page 146

Intel® NetStructureTMZT 7102 Chassis Management Module Warranty Information

Page 147 of the Intel ZT 7102 user manual — G.3 Sales Assistance
Page 147 · click to enlarge
Page 147

Appendix G Customer Support

This appendix offers technical and sales assistance information for this product, and information on returning an Intel NetStructure product for service.

G.2 Technical Support and Return for Service Assistance

For all product returns and support issues, please contact your Intel product distributor or Intel Sales Representative for specific information.

G.3 Sales Assistance

If you have a sales question, please contact your local Intel ® NetStructureTM Sales Representative or the Regional Sales Office for your area. Address, telephone and FAX numbers, and additional information is available at Intel's website, located at:

http://www.intel.com/network/csp/sales/

Intel Corporation Telephone (in U.S.) 1-800-755-4444 Telephone (Outside U.S.) 1-973-993-3030

Customer Support

Page 148 of the Intel ZT 7102 user manual — Appendix G Customer Support
Page 148 · click to enlarge
Page 148

Intel® NetStructureTMZT 7102 Chassis Management Module Customer Support

Page 149 of the Intel ZT 7102 user manual — H.3.6 EN 55024 Immunity
Page 149 · click to enlarge
Page 149

Appendix H Agency Approvals

H.1 CE Certification

The ZT 7102 meets the intent of Directive 89/336/EEC for Electromagnetic Compatibility and Low-Voltage Directive 73/23/EEC for Product Safety. The ZT 7102 has been designed for NEBS/ETSI compliance.

H.2 Safety

UL/cUL 60950 Safety for Information Technology Equipment (UL File # E179737)

EN/IEC 60950 Safety for Information Technology Equipment

CB Report Scheme CB certificate and Report

H.3 Emissions Test Regulations

FCC Part 15, Subpart B

EN 55022

CISPR 22

H.3.5 EN 50081-1 Emissions

GR-1089-CORE Sections 2 and 3

EN 55022 Class A Radiated

EN 55022 Power Line Conducted Emissions

EN 61000-3-2 Power Line Harmonic Emissions

EN 61000-3-3 Power Line Fluctuation and Flicker

H.3.6 EN 55024 Immunity

GR-1089-CORE Sections 2 and 3

EN 61000 4-2 Electro-Static Discharge (ESD)

EN 61000 4-3 Radiated Susceptibility

EN 61000 4-4 Electrical Fast Transient Burst

EN 61000 4-5 Power Line Surge

Agency Approvals · Bellcore GR-1089

Page 150 of the Intel ZT 7102 user manual — H.5 Product Safety Information
Page 150 · click to enlarge
Page 150

Intel® NetStructureTMZT 7102 Chassis Management Module Agency Approvals

EN 61000 4-6 Frequency Magnetic Fields

EN 61000 4-11 Voltage Dips, Variations, and Short Interruptions

H.4 Regulatory Information

H.4.7 FCC (USA)

This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.

This product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

H.4.8 Industry Canada (Canada)

Cet appareil numérique respecte les limites bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Appareils Numériques”, NMB-003 édictée par le Ministre Canadien des Communications.

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the interference-causing equipment standard entitled: “Digital Apparatus,” ICES-003 of the Canadian Department of Communications.

H.5 Product Safety Information

H.5.8.1 Safety Precautions

Review the following precautions to avoid personal injury and prevent damage to this product or products to which it is connected. To avoid potential hazards, use the product only as specified. Read all safety information provided in the component product user manuals and understand the precautions associated with safety symbols, written warnings, and cautions before accessing parts or locations within the unit. Save this document for future reference.

Page 151 of the Intel ZT 7102 user manual — H.4 Regulatory Information
Page 151 · click to enlarge
Page 151

Caution: System environmental requirements: Components such as Processor Boards, Ethernet Switches, etc., are designed to operate with external airflow. Components can be destroyed if they are operated without external airflow. External airflow is normally provided by chassis fans when components are installed in compatible chassis. Never restrict the airflow through the unit's fan or vents. Filler panels or air management boards must be installed in unused chassis slots. Environmental specifications for specific products may differ. Refer to product user manuals for airflow requirements and other environmental specifications.

Caution: Lithium batteries are not field-replaceable units. There is a danger of explosion if a battery is incorrectly replaced or handled. Do not disassemble or recharge the battery. Do not dispose of the battery in fire. When the battery is replaced, the same type or an equivalent type recommended by the manufacturer must be used. Used batteries must be disposed of according to the manufacturer's instructions. Return the unit to Intel for battery service.

Agency Approvals

Page 152 of the Intel ZT 7102 user manual — H.4 Regulatory Information
Page 152 · click to enlarge
Page 152

Intel® NetStructureTMZT 7102 Chassis Management Module Agency Approvals

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
0Success p.106
1Blade isn't in the chassis p.106
2ECMM SVR: Unsupported Command _ Error p.106
3CLI Send Message Error p.106
4Not a valid -t parameter. p.106
5Not a valid -l location. p.106
6Not a valid -d parameter. p.106
7Not a valid -v parameter. p.106
8CLI Invalid Request Error p.106
9CLI Receive Message Error p.106
10No data found to retrieve. p.106
11CLI Data Type Unsupported p.106
12ECMM CLIENT: RPC Connect Error _ p.106
13Invalid auth code passed to RPC interface p.106
14Operation cannot Be Performed on Standby CMM p.106
15The CMM is Initializing and Not Ready. Wait a few seconds and try again. p.106
16Blade does not support IPMI p.106
17BPM Operation cannot Be Performed on Standby CMM p.106
18Couldn't delete a board from the drone mode list p.106
19Not a valid -v parameter p.106
20Internal CMM Error p.106
21Internal CMM Error p.106
22Internal CMM Error p.106
23Internal CMM Error p.106
24Internal CMM Error p.106
25Internal CMM Error p.106
26Internal CMM Error p.106
27CMM Config File Error p.106
28Internal CMM Error p.106
29Internal CMM Error p.106
30Internal CMM Error p.106
31Internal CMM Error p.106
32A blade is not responding to IPMI requests. p.106
33A blade is not responding to IPMI requests. p.106
34An IPMI request returned with a non successful completion code. User should try the command again. p.107
35Invalid IPMI response. Blade may be returning invalid data. p.107
36Invalid IPMI response. Blade may be returning invalid data. p.107
37Invalid IPMI response. Blade may be returning invalid data. p.107
38Internal CMM Error p.107
39Internal CMM Error p.107
40Internal CMM Error p.107
41Internal CMM Error p.107
42Internal CMM Error p.107
43Invalid IPMI response. Blade may be returning invalid data. p.107
44Error setting snmptrap parameters. Retry command p.107
45Internal CMM Error p.107
46Internal CMM Error p.107
47Internal CMM Error p.107
48Internal CMM Error p.107
49Internal CMM Error p.107
50Internal CMM Error p.107
51Internal CMM Error p.107
52Internal CMM Error p.107
53Internal CMM Error p.107
54SNMP Trap address that the user is setting is invalid p.107
55SNMP Community that user is setting is invalid p.107
56SNMP Trap version that the user is setting is invalid p.107
57SNMP Trap port that the user is setting is invalid p.107
58Cannot read SNMP config parameter. Config file may be corrupted. p.107
59Internal CMM Error p.107
60Internal CMM Error p.107
61Can't read SDRs. Blade may be busy, try again. p.107
62Internal CMM Error p.107
63Internal CMM Error p.107
64Internal CMM Error p.108
65Internal CMM Error p.108
66Internal CMM Error p.108
67Internal CMM Error p.108
68Internal CMM Error p.108
69Internal CMM Error p.108
70Internal CMM Error p.108
71Internal CMM Error p.108
72Internal CMM Error p.108
73Internal CMM Error p.108
74Internal CMM Error p.108
75Not a valid -d parameter p.108
76Can't execute this command on the standby CMM p.108
77Internal CMM Error p.108
78Internal CMM Error p.108
79Internal CMM Error p.108
80Internal CMM Error p.108
81Internal CMM Error p.108
82Internal CMM Error p.108
83Internal CMM Error p.108
84Internal CMM Error p.108
85Internal CMM Error p.108
86Internal CMM Error p.108
87Internal CMM Error p.108
88Internal CMM Error p.108
89Internal CMM Error p.108
90The sensor being queried doesn't support a particular threshold p.108
91Internal CMM Error p.108
92Internal CMM Error p.108
93Internal CMM Error p.108
94Internal CMM Error p.108
95Internal CMM Error p.108
96Internal CMM Error p.108
97Internal CMM Error p.108
98Internal CMM Error p.108
99Internal CMM Error p.108
100Internal CMM Error p.109
101Internal CMM Error p.109
102Internal CMM Error p.109
103Internal CMM Error p.109
104Internal CMM Error p.109
105CMM config file may be corrupted p.109
106CMM config file may be corrupted p.109
107The sensor being queried doesn't support a particular threshold. p.109
108The sensor doesn't support a "current” value. This happens when querying a current value on a discrete sensor type. p.109
109Not a valid -l location p.109
110Not a valid -d parameter p.109
111Not a valid -v parameter p.109
112Not a supported command p.109
113Can't execute this command on the standby CMM. p.109
114Internal CMM Error p.109
115Internal CMM Error p.109
116Internal CMM Error p.109
117Internal CMM Error p.109
118Power Supply Not Present Error p.109
119Internal CMM Error p.109
120Internal CMM Error p.109
121Update in Progress p.109
122Initilization message p.109

Ask about the Intel ZT 7102

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Intel ZT 7102

Be the first to ask — other owners or our team will answer.

Original document

Intel ZT 7102 manual PDF

152 pages·1.4 MB·TV Video Accessories·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…