Instruction/ maintenance manual of the product SE7501CW2 Intel
Go to page of 25
Server Inst allation and Integration Guide Using the Boxed Intel ® Xeon Processor and Boxed Intel ® Server Board SE7501CW2.
Intel Server Board SE7501CW2 Installation and Integration Guide Revision History Date Revision Notes Product Code 9/25/03 1 First Draft 10/6/03 2 Second Draft Disclaimers The information contained in .
Intel Server Board SE7501CW2 Installa tion and Integration Guide Table of Contents Introduction ......................................................................................5 Document Ov erview ................................................
Intel Server Board SE7501CW2 Installation and Integration Guide Making Optional Connections to the Server Board ................................. 17 Installing the Seri al B Cable .................................................................. 18 Cable Routing – Intel Se rver Chassis SC5200 .
Intel Server Board SE7501CW2 Installa tion and Integration Guide Introduction Document Overview This guide outlin es the procedures for integratin g an Intel ® Server Platform using an Inte l Server Board SE7501CW2 and Intel Xeon processors.
Intel Server Board SE7501CW2 Installation and Integration Guide Troubleshooting Guide In the unlikely event yo u do encounter issues, the troubleshooting gu ide will help you troubleshoot and identify possible areas of concern regarding the Intel Server Board SE7501CW2.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Hardware Integration The following in stallation procedures enable y ou to prepare a chassis for integration, add the needed components to your server board, and install the server board.
Intel Server Board SE7501CW2 Installation and Integration Guide Important Safety Information Safety Instructions and Information To avoid personal injury or property dama ge, the following safety instructions apply whenever working in side the chassis: 1.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Chassis Preparation and Server Board Installation About the I/O Shield An ATX 2.03-compliant I/O shield is provided wi th your server board. The shield is required by Electromagnetic Interference (EMI) regul ation s.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing Chassis Standoffs If your chassis does not have stando ffs placed as shown, you must rearrange them so t hey match the hol es in the server board. Failure to properly rearrange the metal standoffs may cause the server board to malfunc tion and permanently damage it.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Installing Memory The server board supports only DDR266- compliant DIMMs. The minimum supported memory configuration is 128 MB, using one 128-MB DIMM. The maximum configurable memory size is 8 GB using 4 2-GB DIMMs.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Boxed Intel Xeon Processor Choosing the Processor Socket Use these instruction s for installing you r processor instead of the instruction s that came with your boxed processor.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Installing the Retention Mechanism 1. Insert the retention brackets. 2. Tighten the four retention screws. Applying Thermal Grease Apply thermal grease to the processor as shown. Attaching the Heat Sink and Retention Clips 1.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Processor Wind Tunnel The following in structions apply to the base Intel Server Chassis SC5200 an d reference chassis installations. Di rect the airflow from the processor wind tunnel toward the rear of the chassis as shown.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Attaching the Wind Tunnel 1. Spread the tabs outward sli ghtly (1a). Lower the wi nd tunnel assembly onto the retention mechani sm (1b). 2. The tabs on the fan assembly (2a) slide into slot s (2b) on the inner side of t 3.
Intel Server Board SE7501CW2 Installation and Integration Guide Making Required Connections to the Server Board Make these connections regardless of the chassi s used.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Making Optional Connections to the Server Board These connections are required only when th e corresponding component is installed.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Serial B Cable For the Intel Server Chassis SC5200, yo u can connect the Serial Port B cable to either th e back of the chassis or, on a rack-mount system, to the front of the chassis.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Cable Routing – Intel Server Chassis SC5200 routing guidelines below. sys 1. bles as shown. Floppy and Front Panel Cables Route the floppy drive and front panel cables as shown. Installing the Access Cover 1.
Intel Server Board SE7501CW2 Installation and Integration Guide Installing the Chassis Feet (Pedestal Mode) 1. If you are installing t his server into a rack syst em, skip these steps and go to “Installing in to a Rack (Rack kbench. assis. The th only one set of holes in oot, the middle hole should face toward the front of the chassis.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Finishing Up WARNING tall the chassis access cover before finishing ver” on page 19). An Ins up (see ”Installing the Access Co electrical shock hazar d exists if the chassis access cover is wer.
Intel Server Board SE7501CW2 Installation and Integration Guide Software Installation Updating the BIOS Intel highly recommends tha t you go to th e Intel Server Board SE7501CW2 supp ort Web ite and download and install the latest syste m BIOS update for your operating system.
Intel Server Board SE7501CW2 Installa tion and Integration Guide LANDesk* Client Manager ma nage a computer an d troubleshoot common computer problems. Use Client Mana ger to: nt computers (single, • Client: The client version enables an en d user to view informat ion and manage alerts for a local computer.
Intel Server Board SE7501CW2 Installation and Integration Guide Intel Server Maintenance and Reference Training Tool CD enance and Reference Traini ng Tool CD (Intel SMaRT Tool ) is an providing support in formation to assist with th e maintenance and repair of Intel processor-based server sy stems and accessories.
Intel Server Board SE7501CW2 Installa tion and Integration Guide Thank you for purchasing Intel products! For additional integration reso urces, please visit www.
An important point after buying a device Intel SE7501CW2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Intel SE7501CW2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Intel SE7501CW2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Intel SE7501CW2 you will learn all the available features of the product, as well as information on its operation. The information that you get Intel SE7501CW2 will certainly help you make a decision on the purchase.
If you already are a holder of Intel SE7501CW2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Intel SE7501CW2.
However, one of the most important roles played by the user manual is to help in solving problems with Intel SE7501CW2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Intel SE7501CW2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center