INGERSOLL RAND COMP ANY L TD 209 NORTH MAIN STREET -- BRYAN, OHIO 43506 (800) 495-0276 y F AX (800) 892-6276 © 2010 CCN 15275290 OPERA T OR’ S MANU AL PD07X -X - X INCL UDING: OPERA TION, INST ALLA TION & MAINTENANCE RELEASED: 2-20-07 REVISED: 5-21-10 (REV .
Page 2 of 8 PD07X- X-X (en) W ARNING EX CESSIVE AIR PRESSURE. Can cause per- sonal injury , pump damage or property damage. Do not ex ceed the maximum inlet air pr essure as stated on the pump model plate . Be sure material hoses and other componen ts are able to withstand fluid pressures dev eloped by this pump .
PD07X- X-X (en) Page 3 of 8 y Hytrel® is registered trademarks of the DuP ont Company y Santoprene® is a register ed trademark of Monsanto Company , licensed to Advanced Elastomer Systems, L.
Page 4 of 8 PD07X- X-X (en) P ARTS LIST / PD07X- X -X FL UID SEC TION 637427-X X Fluid Section Ser vice Kits include: Balls (see Ball Option, refer to - XX in chart below), Diaphragms (see Diaphragm O p- tion, refer to - XX in chart below), and item 19 (listed below) plus items 144, 174 and 94276 Lubripla te® FML -2 grease (page 6).
PD07X- X-X (en) Page 5 of 8 ) T ORQUE REQUIREMENTS ( NO TE: DO NOT O VERTIGHTEN F ASTENERS. (14) Bolt, 95 - 105 in. lbs (10.7 - 11.9 Nm). (26) Bolt, 50 - 60 in. lbs (5.6 - 6.8 Nm), / alternately and ev enly , then re - torque after initial run-in. (29) Nut, 50 - 60 in.
Page 6 of 8 PD07X- X-X (en) P ARTS LIST / PD07X- X -X AIR MO T OR SECTION 9 Indica tes parts included in 637428 air sec tion repair kit. MA TERIAL C ODE [B] = Nitrile [PPG] = Glass Filled Polypr opyle.
PD07X- X-X (en) Page 7 of 8 P ARTS LIST / PD07X- X -X AIR MO T OR SECTION ) 134 138 139 135 107 171 121 166 201 (optional) 129 130 137 111 ) T ORQUE REQUIREMENTS ( NO TE: DO NOT O VERTIGHTEN F ASTENERS. (123) Torque to 4 - 6 in. lbs (0.
Page 8 of 8 PD07X- X-X (en) PN 97999-1226 TROUBLE SHOO TING Product discharged from air e xhaust. Check for diaphragm ruptur e. Check tightness of (14) bolt. Air bubbles in product discharge. Check connections of suction plumbing. Check “O” rings between intake manifold and uid caps.
An important point after buying a device Ingersoll-Rand PD07X-X-X (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Ingersoll-Rand PD07X-X-X yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Ingersoll-Rand PD07X-X-X - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Ingersoll-Rand PD07X-X-X you will learn all the available features of the product, as well as information on its operation. The information that you get Ingersoll-Rand PD07X-X-X will certainly help you make a decision on the purchase.
If you already are a holder of Ingersoll-Rand PD07X-X-X, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Ingersoll-Rand PD07X-X-X.
However, one of the most important roles played by the user manual is to help in solving problems with Ingersoll-Rand PD07X-X-X. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Ingersoll-Rand PD07X-X-X along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center