Instruction/ maintenance manual of the product Blood pressure monitor BP5 iHealth
Go to page of 17
iHealth™ Wireless Blood Pressure Monitor (BP5) OWNER’S MANUAL Table of Contents INTRODUCTION ................................................................................................................................. 2 PACKAGE CONTENTS .....
2 INTRODUCTION Thank you for selecting the iHealth Wireless Blood Pressure Monitor. The iHealth Wireless Blood Pressure Monitor is a fully automatic arm cuff blood pressure monitor that uses the oscillometric principle to measure your blood pressure and pulse rate.
3 CONTRAINDICATION It is not recommended for people with serious arrhythmia to use this Wireless Blood Pressure Monitor. PARTS AND DISPLAY INDICATORS SET UP REQUIREMENTS The iHealth Wireless Blood Pre.
4 Connect to iOS Device via Bluetooth • Apply the cuff or press the START/STOP button, the Bluetooth indicator will begin flashing. • Turn Bluetooth "On" under the "Settings" menu on the iOS device. • Wait until the model name printed on the monitor, (i.
5 Lying Down During Measurement a. Lie on your back. b. Place your arm straight along your side with your hand palm-side up. c. The cuff should be placed at the same level as your heart. Note: Blood pressure can be affected by the position of the cuff and your physiologic condition.
6 During measurement, press the “START/STOP” button to stop measurement. Press the “START/STOP” button for 2 seconds to turn off the monitor manually. Auto Connect Option Auto connect option allows the monitor to find the last used iOS device and re-establish the connection automatically.
7 measurement 8. Memory volume: 120 times with time and date stamp (off-line measurement only) 9. Power: DC: 5.0V 1.0A, Battery: 1*3.7V Li-ion 400mAh 10. Measurement range: Cuff pressure: 0-300 mmHg Systolic: 60-260 mmHg Diastolic: 40-199 mmHg Pulse rate: 40-180 beats/minute 11.
8 device be set in Airplane mode during measurement to avoid strong magnetism interference. 6. If Irregular Heartbeat (IHB) is detected during the measurement procedure, the IHB symbol will be displayed. Under this condition, the Wireless Blood Pressure Monitor can keep functioning, but the results may be inaccurate.
9 BATTERY HANDLING AND USAGE • When the monitor is connected to the iOS device, the battery volume will be displayed on the iOS device. If the power is less than 25%, please charge the battery. The monitor will not work until the battery has enough power.
10 The cuff does not inflate properly or pressure falls quickly during test Review the cuff application instructions and retest Irregular heartbeat (arrhythmia) It is inappropriate for people with serious arrhythmia to use this monitor. Check with physician.
11 CARE AND MAINTENANCE 1. If this monitor is stored near freezing temperatures, allow it to acclimate to room temperature before use. 2. If the monitor is not used for a long time, please sure to fully charge it every month. 3. It is recommended that product performance be checked every 2 years or after each repair.
12 EXPLANATION OF SYMBOLS Symbol for “TYPE BF APPLIED PARTS” (Cuff only) Symbol for ”THE OPERATION GUIDE MUST BE READ” The sign background color: blue The sign graphical symbol: white Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste.
13 EC REP Lotus Global Co., L td. 15 Alexandra Road, L ondon U K, N W8 0 DP Tel: +0044-20-75868010 F ax: + 0044-20-79006187 ANDON HEALTH CO., LTD. No. 3 Jinping Street, Y a A n R oad, N ankai D istrict, Tianjin 300190, China Tel: 86-22-60526161 IMPORTANT INFORMATION REQUIRED BY THE FCC This device complies with Part 15 of the FCC Rules.
14 IEC 60601-1-2:2007 (Medical electrical equipment – Part 1: General requirements for safety; Collateral Standard-Electromagnetic compatibility - Requirements and tests); EN 1060-1: 1995 + A1: 2002.
15 ic discharge (ESD) IEC 61000-4-2 ± 8 kV air ± 8 kV air concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30 %.
16 Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 150 kHz to 80 MHz 3 V/m 80 MHz to 2.5 GHz 3V 3 V/m recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Recommended separation distance : 80 MHz to 800 MHz 800 MHz to 2.
17 portable and mobile RF communications equipment and the Wireless Blood Pressure Monitor The Wireless Blood Pressure Monitor is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
An important point after buying a device iHealth Blood pressure monitor BP5 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought iHealth Blood pressure monitor BP5 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data iHealth Blood pressure monitor BP5 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, iHealth Blood pressure monitor BP5 you will learn all the available features of the product, as well as information on its operation. The information that you get iHealth Blood pressure monitor BP5 will certainly help you make a decision on the purchase.
If you already are a holder of iHealth Blood pressure monitor BP5, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime iHealth Blood pressure monitor BP5.
However, one of the most important roles played by the user manual is to help in solving problems with iHealth Blood pressure monitor BP5. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device iHealth Blood pressure monitor BP5 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center