IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-095 The Service Informatio n provides the fo llowing informa tion: • Precautions and safety inform ation • Specifications • Performance test pro.
TABLE OF CONTENTS Title Page # Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 Specifications 3 General Specification 3 Voltage Specifications 4 Resistance and C ontinuity Speci.
Page 1 Introduction Warning To avoid shock or injury, do not perform the verification tests or cali bration procedures described in this manual unless you are qualified to do so. The information provided in this document is for the use of qualified personnel only.
Page 2 SAFETY Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential h azards, use the product only as specified. CAUTION. These statements identify conditions or practices that cou ld result in damage to the equipment or other property.
Page 3 SPECIFICATIONS All specifications are warrant ed unless noted typical and appl y to the 61-095. Stated accuracies are at 23º C ± 5ºC at less than 80% relative humidity and without the battery indicator display ed. General specifications Characteristics Description LCD display digi ts 3 ½ Display count 2,000 Numeric update rat e 2.
Page 4 Measurement Characteristics Accuracy is ±(% reading + num ber of digits) at 2 3ºC ± 5º C, less than 80% R .H. Voltage Function Range Accuracy Overload protection V 600 Vrms ± (1.5%+ 3 dgt) 40Hz ~ 500Hz 600 Vrm s V 600 V ± (1% + 2 dgt) Input impedance: 1M Ω // less than 100pF.
Page 5 Physical and Environmental Characteristi cs Physical Characteristics Description Dimensi ons (H x W x D) 188mm x 66mm x 42mm Weight (with battery) 0.3Kg Environmental Characteristics Description Temperature operating 0 to + 50º C Non-Operating -20 to + 60º C Humidit y (operating) < 80% R.
Page 6 Required Equipment Required equipment is listed in Tab le B. If the recommended m odels are no t available, equ ipment with equivalent specifications m ay be used. Repairs or servicing s hould be perform ed only by qualified personnel. Table B.
Page 7 Basic Maintenance Warning To avoid shock, remove the te st leads and any input signal s before opening the case or replacing the battery or fuses. Opening the Meter Case Caution To avoid unintentional short circu it, always place the uncovered meter assembly on a protective surface.
Page 8 Performance Tests The following perform ance tests verify the complete ope rability of the meter and check the accuracy of each meter function against the meter’s specifications.
Page 9 Testing the Resistance Function To verify the accuracy of the re sistance function, do the following: 1. Connect the calib rator to V Ω and COM on the meter. 2. Turn the rotary switch to Ω . 3. Apply the inputs for step 1-4 i n Table 3. 4. Compare the meter display readings to the display reading s in Table 3.
Page 10 OK Figure 2 Top shows correct method; bo ttom shows incorrect method. Calibration Calibrate the meter once a year to ensure that it perform s according to specifications. Per fo rm ca lib ra tio n at an a mbi ent t empe ra tu re o f 23ºC ± 2ºC and relative humidity of 75% or less.
Form number TM61095 Rev 2 September 2002 Page 11 Figure 3 - Calibration Adjustment Points.
An important point after buying a device IDEAL INDUSTRIES 61-095 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought IDEAL INDUSTRIES 61-095 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data IDEAL INDUSTRIES 61-095 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, IDEAL INDUSTRIES 61-095 you will learn all the available features of the product, as well as information on its operation. The information that you get IDEAL INDUSTRIES 61-095 will certainly help you make a decision on the purchase.
If you already are a holder of IDEAL INDUSTRIES 61-095, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime IDEAL INDUSTRIES 61-095.
However, one of the most important roles played by the user manual is to help in solving problems with IDEAL INDUSTRIES 61-095. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device IDEAL INDUSTRIES 61-095 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center