Shielded T wisted P air ( S TP) Cable Stripping System F or 115V or 23 0V Operation Manual #45-930 #45-935.
2 T able of Contents Introduction ..................................................................... 2 Caution and Safety Instructions ....................................... 3 Environmental Conditions ..............................................
Caution and Safety Instructions Please read, understand and follow the warnings and instructions in this manual. Failure to do so can result in serious personal injury. • Do not alter, modify or misuse the machine. • Do not operate the machine using an ungrounded electrical system.
4 STP Ser vice Setup Continued Electrical Connection Requirements Voltage Selection The STP operates on either 115V/230V AC; 45-930, 115V AC 4A 60 Hz ; 45-935, 230V AC 2A 50 Hz. Proper voltage will be preset at the factory. Fuse Replacement Disconnect power cord and remove the fuse cartridge using a small blade screwdriver or similar tool.
5 STP Operating Principles and T erms (continued) SPEED: Thermal Head Rotation SPEED refers to the rate of rotation by the Thermal Head of the STP. This is the rate at which the blades are rotated about the wire being stripped. The slowest speed is 1 and 10 the highest.
6 STP Operation continued Heat Adjustment Heat can be adjusted by pressing [ 0 ] through [ 9 ] producing corresponding heat values of 0% through 90%. Pressing HIGH sets the heat at 100%. If the heat is set at 0%, the machine completes the cycle without using the blades.
STP Operation continued Strip Length Adjustment, by Discrete Value METRIC LENGTH MODE (31 mm to 152 mm) • Press STRIP LENGTH . • The strip length display will blink. • Enter the strip length and then press ENTER . A strip length is automatically entered after a third digit is pressed.
8 STP Operation continued TWO STAGE CYCLE The TWO STAGE CYCLE is intended to break the STP’s stripping cycle into two separate stages; stage one is for cutting, stage two is removal. When the cable is inserted, the first stage will thermally cut the insulation.
STP Operation continued Slug Removal SINGLE CYCLE The STP can be used to remove the slug without applying heat to the blades, if the insulation has already been severed. This is accomplished by pressing “ 0 ” when the unit is in the “ READY MODE ”.
10 STP Operation continued Set Mode 1 — STRIP LENGTH INCREMENT This allows programming the strip length in increments by using the arrow keys to increase or decrease the length appearing on the display. ENGLISH LENGTH MODE - (0.01 in. to 0.99 in.) The tenths position begins blinking.
STP Operation continued Batching Storing a Batch • Press BATCH • Press PROGRAM • Enter the 3-digit security code • Enter in the batch number for storage • Press ENTER All of the current inputs are then stored in this batch. Press CLEAR to exit to the ready mode.
12 Name Part No. Quantity Per Unit Blade Set K-7763 1 Front Grip Pad LA2408 2 Rear Grip Pad LA2414 6 STP Ser vice continued 3 — GRIP BACK SENSOR (senses if the pull cylinder is back) 4 — TRIGGER S.
STP Operation continued Gripper Pad Replacement The STP has two sets of grippers. The front grippers hold the wire while the rear grippers pull off the slug.
Rear Gripper Pad Replacement 1. Disconnect power 2. Disconnect air 3. Open case Caution blades may be hot. STP Ser vice continued A NEEDLE-NOSE PLIER MAY BE USED TO REMOVE THE PINS. MOVE TO RIGHT, THEN TO REAR 6. Remove grippers. Stationary gripper slides straight out.
STP Ser vice continued Blade Replacement 1. Electronically set strip length to 6". This moves the stop bar all the way back allowing more room to replace the blades. 2. Disconnect power. (rear gripper will retract all the way back). 3. Disconnect air.
9. Remove the four #4-40 socket head screws positioning blades. 10. Pull elements guiding lead wire through holes. 11. Reverse the process by feeding the new blade wires through the holes and silicone tubes. 12. Replace the four #4-40 socket head screws for positioning blades.
17 CPU Module Replacement The CPU Module (Central Processing Unit) and the Power Module are not field repairable, they must be returned to IDEAL for service. The CPU is located behind the faceplate on the inside of front lid. 1. Disconnect power. 2. Disconnect air.
18 Always disconnect power and air when servicing the unit. Please read the Operation Manual thoroughly before attempting to operate the STP. SYMPTOM RECOMMENDATIONS • Unit does not turn on. ✔ Check electrical connections. ✔ Check electrical supply.
STP Machine Assembly *Refer to Sub Assemblies with their own parts lists on pages 16 and 17. 19 Heat Speed Pressure Pragm. High Batch Enter • Count Clear Strip Length 8 90 LEN HEAT PSI SPD Item Qty Name Part No.
20 Item Qty Name Part No. 1 1 Assy, Interface Board K-7468 2 1 Assy, Pressure Regulator K-7749 3 1 Air Solenoid 392.002 4 1 Assy, Power Supply IA3273 5 1 Air Reservoir 392.005 T op Shelf Assembly 5 1 3 2 4 1 1 1 2 2 1 2 3 4 Item Qty Name Part No. 1 6 ft Tubing .
21 5 7 12 1 3 9 10 8 2 6 4 11 Item Qty Name Part No. 1 2 Rod Support Bar K-7554 2 1 Cylinder Bar K-7555 3 1 Stop Bar K-7556 4 1 Motor Driver Rod K-7560 5 1 Follower Rod K-7561 6 2 Rod K-7562 7 4 Bearing 21.059 8 2 Fiber Bushing 24.049 9 2 Sprocket 123.
+5V LOGIC POWER SUPPL Y - + DISPL AY KEYBOARD TRANSPOR T MOTOR THERMAL HEAD MOTOR PRES SURE REGULATOR ASSEMBL Y AIR INPUT AIR OUT TO REAR GRIP SOLENOID AIR BL AST SOLENOID TRANSPOR T SOLENOID WIRE SUP.
Warranty limited solely to repair or replacement; no warranty of merchantability, fitness for a particular purpose or consequential damages. 1000 Park Avenue, Sycamore, IL 60178 – Manufacturing Facility IDEAL INDUSTRIES, INC. Becker Place, Sycamore, IL 60178 – 800-435-0705 in U.
An important point after buying a device IDEAL INDUSTRIES 45-930 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought IDEAL INDUSTRIES 45-930 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data IDEAL INDUSTRIES 45-930 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, IDEAL INDUSTRIES 45-930 you will learn all the available features of the product, as well as information on its operation. The information that you get IDEAL INDUSTRIES 45-930 will certainly help you make a decision on the purchase.
If you already are a holder of IDEAL INDUSTRIES 45-930, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime IDEAL INDUSTRIES 45-930.
However, one of the most important roles played by the user manual is to help in solving problems with IDEAL INDUSTRIES 45-930. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device IDEAL INDUSTRIES 45-930 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center