Modbus Plus X-Link Driver User’s Guide Version 1.22 50 Northland Road Waterloo, Ontario, CANADA N2V 1N3 Tel: (519) 725- 5136 Fax: (519) 725-1515 www.
Modbus Plus X-Link Driver User’s Guide 36 Publication Revision: 1.22 Publication Date: January 15, 1999 This document applies to the Modbus Plus X-Link Driver (SA85.DRV). Copyright © 1999 SST, a division of Woodhead Canada Limited All rights reserved.
Modbus Plus X-Link Driver User’s Guide 37 Contents 1. Introduction ........................................................... 39 1.1 What is the Modbus Plus Driver? ............................. 39 1.2 Why Do I Need This Manual? ...................
Modbus Plus X-Link Driver User’s Guide 38.
Introduction 39 1 Introduction 1.1 What is the Modbus Plus Driver? The Modicon Modbus Plus X-Link driver allows the X-Link to transfer data to or from devices on the Modicon Modbus Plus network.
Modbus Plus X-Link Driver User’s Guide 40 1.2 Why Do I Need This Manual? This manual describes the communication requirements and capabilities of the Modbus Plus driver, the configuration parameters for the driver and the mappings possible for the Modicon PLCs.
Introduction 41 1.3 How Do I Use This Manual? The following conventions will help you better understand and use the material in this manual. Text you type appears in Courier font. For example, “Type mkdir C:XLINK to make a new X-Link directory.” Menu Names are italicized.
Modbus Plus X-Link Driver User’s Guide 42 1.4 Where Can I Find More Help? If you have a question or problem that the manuals or on-line help do not address, you can contact X-Link Technical Support by mail, fax or email, or by phone during regular business hours (EST).
Communication 43 2 Communication Once configured, the X-Link emulates a station on the Modbus Plus network. It can send messages to other stations and receive messages from other stations. This section outlines the requirements and compatibilities of this communication.
Modbus Plus X-Link Driver User’s Guide 44 2.1 Requirements To communicate to the Modbus Plus network, the X-Link requires a Modicon SA85 card. The X-Link Modbus Plus driver supports either the redundant or non-redundant version of the SA85.
Configuration 45 3 Configuration When you download a driver to the X-Link, you must set configuration parameters to control the interface between the driver and the required hardware. This section details the configuration parameters for the Modbus Plus driver.
Modbus Plus X-Link Driver User’s Guide 46 3.1 Configuration Parameters The Modbus Plus driver is distributed in the file SA85.DRV. Once the SA85.DRV is loaded into the X -Link, the following parameters are required: Card Segment The memory address for the SA85 card.
Mappings 47 4 Mappings Once the X-Link has been loaded, you can create mappings to transfer data from one network to the other. This section outlines the mapping options supported by the Modbus Plus driver. For information on what mappings are or how they work, please refer to the X-Link User's Guide .
Modbus Plus X-Link Driver User’s Guide 48 4.1 Data Ty pes and Lengths The Modbus Plus Driver supports three X-Link data formats; Bits and Integers, as well as Floats.
Mappings 49 4.2 Source Accesses The Modbus Plus driver supports four possible source accesses. The first source defines a local address which allows any device on the Modbus Plus network to write the data to the X-Link. This type of source is ideal for data that changes infrequently, but must be forwarded immediately, such as errors or exceptions.
Modbus Plus X-Link Driver User’s Guide 50 4.3 Destination Accesses The Modbus Plus driver supports three possible destination accesses. The first destination defines a local address which allows any device on the Modbus Plus network to read the data from the X-Link.
Mappings 51 4.4 Local Addresses When a mapping is created which allows a PLC to access data within the X -Link, a local address dialog box must be completed. The information required to complete a local address definition is the class of data to access (Coils, Input Status, Input Registers or Holding Registers) and the offset into the data table.
Modbus Plus X-Link Driver User’s Guide 52 4.6 Status Counters The status counters are maintained within the Modbus Plus driver for logging events and errors. The Status menu allows you to monitor some of these counters. As well, the status counters can be accessed as a data source for mappings.
Troubleshooting 53 5 Troubleshooting If you cannot communicate with your X-Link, refer to the troubleshooting section in the X-Link User's Guide. If you can communicate with your X-Link, but cannot monitor the status of your Modbus Plus driver, you most likely have the memory address set incorrectly.
Modbus Plus X-Link Driver User’s Guide 54.
Specification 55 6 Specification 6.1 Driver CMOS Storage Requirements Driver Code and Parameters 16 Kbytes Each Global Data Read Address 4 bytes Each Global Data Write Address 3 bytes Each Internal Ad.
Modbus Plus X-Link Driver User’s Guide 56.
An important point after buying a device IBM Modbus Plus (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought IBM Modbus Plus yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data IBM Modbus Plus - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, IBM Modbus Plus you will learn all the available features of the product, as well as information on its operation. The information that you get IBM Modbus Plus will certainly help you make a decision on the purchase.
If you already are a holder of IBM Modbus Plus, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime IBM Modbus Plus.
However, one of the most important roles played by the user manual is to help in solving problems with IBM Modbus Plus. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device IBM Modbus Plus along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center