The i-data Printing Solutions
ida FS 250 / ida FS 250 PDS Operator’s Guide
Doc. no D60256 Revision 03
WARNING: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such inter- ference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. EMC directive: This product observes the rules and regulations of the EMC directive. If so required, a declaration of conformity in local language stipulating the applied rules and regulations can be obtained. Trademarks: Company and product names mentioned in this datasheet are trademarks or registered trademarks of their respective owners. i-data international a-s cannot be held responsible for any technical or typographical errors and reserves the right to make changes to products and documentation without prior notification.


ida FS 250, Operator's Guide
Document No.: D60256-03 © Copyright i-data international a-s 1997
i-data international a-s Vadstrupvej 35-43 DK-2880 Bagsvaerd Denmark Telephone: +45 44 36 60 00 Telefax: +45 44 36 61 11
i-data Denmark Vadstrupvej 35 DK-2880 Bagsvaerd Denmark Telephone: +45 44 44 77 50 Telefax: +45 44 44 85 50
i-data Sweden Datavägen 21 S-43600 Askim Sweden Telephone: + 46 31 680710 Telefax: + 46 31 682670
i-data UK Ltd. Unit 3, Cartel Business Centre Stroudley Road Basingstoke, Hants RG24 8FW United Kingdom Telephone: + 44 1256 460033 Telefax: + 44 1256 460066
i-data France Parc de Haute Technologie 2, rue Alexis de Tocqueville 92183 Antony Cedex France Telephone: + 33 1 46114340 Telefax: + 33 1 46114341
i-data, Inc. 250-V Executive Drive Edgewood New York 11717 U.S.A. Telephone: +1 (516) 243-6600 Telefax: +1 (516) 243-6500
i-data Australia Pty. Ltd. 14, Gipps Street Collingwood, Victoria 3066 Australia
Founded in 1981 to provide direct attachment of PC laser printers in SNA environments, i-data has grown to become the world leader in printer connectivity technology. With the advent of network attached printers, i-data expanded its product range to include comprehensive host-to-LAN printing concepts, in addition to the traditional Coax and Twinax interfaces.
All i-data products are designed to complement IBM’s own printing strategy, yet also provide the flexibility needed to conform to the specialised needs of large enterprises.
i-data products and services are marketed worldwide through the company’s comprehensive network of sales, offices and distributors.

Table of Contents ida FS 250, Operator's Guide
This manual applies to the ida FS 250 and the ida FS 250 PDS protocol converters.
The ida FS 250 supports twinax Centronics and RS232 inputs. The default output is Centronics.
The manual describes how the ida FS 250 is connected and operated. Read it before you start using the protocol conver ter and keep the manual in a safe place for future referen ce.
It is assumed that the reader has a basic knowledge and under standing of IBM computer systems, especially the IBM 5250 Information Display System. It is also assumed that the reader has adequate knowledge of the printer which is going to be connected to the ida FS 250.
The ida FS 250 can be used with all PCL 4/5 printers .
"MakeITDS" Document No.: D60253
“MakeITDS for VM/MVS, Setup Guide” Document No.: D60272
"5250 Programmer's Guide" Document no. D62079.

Table of Contents ida FS 250, Operator's Guide
As the ida FS 250 emulates the IBM 3812 printer in IBM 5219 emulation, useful information may be obtained from:
"IBM 5219 Printer, Models DO1/DO2, Programmer's Reference Guide" IBM Order no. GA 23-1025
"Using the IBM Page printer 3812 with an IBM System /36 or System /38" IBM Order no. S544-3343
"AS/400 Device Configuration Guide", IBM Order no. SC21-8106


Kit Contents ida FS 250, Operator's Guide
Please check that your kit is complete with the following:
ida FS 250 PDS • Same contents as above except converter comes equipped with IPDS module
In addition the following i-data accessories can be used:
IPDS Upgrade Kit • IPDS option (for upgrade), ida PDS Supra (Order no. 993011-001)

Introduction ida FS 250, Operator's Guide
This chapter gives a short description of the ida FS 250 converter
The ida FS 250 is a protocol converter which enables any printer to be connected to an IBM computer system. See Section 1.3, Supported Control Units, for information on the IBM systems to which the ida FS 250 connects.
The printer or device should have either a Centronics Parallel connector or an RS 232 serial connector in order to be con nected to the ida FS 250 protocol converter.
The ida FS 250 protocol converter gives you the following fea tures:

Introduction ida FS 250, Operator's Guide
The ida FS 250 will connect to the following control units :

Connecting to System ida FS 250, Operator's Guide
Before connecting the ida FS 250, you should check the requirements described in this chapter.
The ida FS 250 protocol converter can be installed in the following environment:
The equipment must be grounded. Operation without a ground may cause exposed metal parts to carry main voltage. This can lead to malfunction and personal injury.
Prior to installation and connection you must first make sure that you have set the desired national language - do this via the line (activating function Y8). See the section: National Language Selection.
Via the Line (Function 8) Below is a short description of how you change national language via the line (Function 8). For further details on programming the ida FS 250, please see the chapter: Programming ida FS 250.
The commands shown in Figure 1-1 have to be sent to the ida FS 250 . You can either do this in a file you transmit to the printer or by entering the command sequence on your screen and making a local copy (print screen).

Connecting to System ida FS 250, Operator's Guide

Your can select between the following languages:

EU = multinational US = English (US) EBCDIC
When you receive the ida FS 250, the interface is already in the box and is ready to connect to the system and to the printer. From the factory, the ida FS 250 is set up for either US (Letter) or European (A4) paper size depending on what you specified when ordering the ida FS 250.
In the event that you should have to change this setting, please contact your point of purchase for instructions.

Connecting to System ida FS 250, Operator's Guide
This chapter starts with an overview of the functionality of the rear panel. Then follows a description of how you connect the ida FS 250 box to a printer and finally you will find instructions for connection to a system.
RS232 12-18 VDC.
5 4 3 2 01
0.7A
A = PCL
Fig 2-1 ida FS 250 Rear Panel
PARALLEL OUT The parallel output port is connected to the parallel/Centronics in put port on the target printer (standard parallel out cable supplied with printer should be used).
PARALLEL IN The parallel input port can be connected to the parallel/Centronics out put on a PC or similar source which enables it to share the printer with the host. For this connection you need a spare part cable ending in a 25-pole D-Sub connector (i-data order no. 999022 030).
SERIAL (IN/OUT) RS232 The serial port can be configured either as input or as output. Default configuration is input.
Serial input The serial port is connected to the serial output on a PC or similar source able to share the printer with the host.

Connecting to System ida FS 250, Operator's Guide
For this connection you need a spare cable ending in a 25-pole RS connector (i-data order no. 999010 030).
To use the serial input, Function 24 Data Input/Output Port Select must be set to zero (which is factory default).
Y24 = 0 is also used for Centronics output.
On the PC you must also make the following settings to match the default settings on the box:
Function Y15: Baud rate, set to 5 = 9600 Function Y16: Number of data bits, set to 8 = 8 bits Function Y17: Parity, set to 1 = No Parity Function Y18, Number of Stop Bits, set to 1 = 1 Stop Bit
If this is not possible, you must change the functions 15, 16, 17 and 18 on the box to match the PC's values.
TWINAX CONNECTOR Before the twinax cable is connected, be sure to turn the box power OFF.
When power is turned off, plug the automatically terminating twinax T-cable into the socket on the rear panel and turn the connector ring clockwise to lock.
ADDRESS SWITCH: EMULATION & PRINTER DRIVER SELECTION You use the address switch for selecting/changing emulation, setting the address and for generating test printouts. Tests can also be made via the line. See the section Testing for details.
For details on emulation see the section : Emulation
The switch is also for future printer driver selection. Note that the device is set to PCL mode as a default which is the only supported printer driver mode. Do not attempt to change this.

Connecting to System ida FS 250, Operator's Guide
As a default the ida FS 250 will emulate IBM 3812/5219/3816.
The ida FS 250 PDS emulates IPDS as a default.
You can select emulation in two ways. Either via the address switch or via the line using FSL function Y37.
The following emulations are supported by the ida FS 250:
IBM 3812/5219/3816 IBM 5224 IBM 5225 IBM 5256 IBM 4234 If you wish to see the current emulation, you can generate a test printout by turning the address switch to the T-position.
Emulation selected on the address switch is described below.
The T-cable must be disconnected from the converter before changing emulation.
power on.
Select emulation on the address switch as follows:
"Current emulation is xxxx"

Connecting to System ida FS 250, Operator's Guide
Non-IPDS Selection Emulation *0 3812 / 5219 / 3816 1 5224 2 5225 3 5256 4 4234 5 3812/5219/ 3816 * default value Matrix printers
Selecting emulation via address switch
Check whether the configuration complies with the requirements of your installation and print jobs.
You can set the desired emulation in FSL function Y37 1. Note that if you select emulation via function 37, you must physically write the emulation. See the chart in the following for details.
E.g. %Y37,5224% will select emulation 5224
%Y37,3812% will select emulation 3812/5219/3816
Below you will find information on the emulations which can be selected in the n1 parameter of function Y37.
1For further details on programming the ida FS 250, please see the chapter: Programming ida FS 250.

Connecting to System ida FS 250, Operator's Guide
Y37,n1 Write Emulation 3812 *3812 / 5219 / 3816 5224 5224 5225 5225 5256 5256 4234 4234 * default value SCS printers
Selecting emulation via the line
The default configuration of the ida FS 250 can be used for most application programs and uses. You should only change the address and the emulation. The rest of the settings should only be changed if you have special requirements.
If you need to upgrade your ida FS 250 with the IPDS module, please follow these instruction before proceeding with the installation.

Connecting to System ida FS 250, Operator's Guide
Connecting the ida FS 250 to the printer is done by following these steps:
The interface can be set up in many ways. From the factory, the interface has been set up to cover most needs and uses. Appendix B.: "Test Printout" is a sample printout of settings and is just one way of setting up your interface.
Keep the settings printout you make together with this manual for future reference.
If the printout format does not match the test printout in Appendix B., or if nothing was printed, this means that the printer setup does not match the protocol converter setup. Contact your systems support personnel or your i-data dealer for assistance.

Connecting to System ida FS 250, Operator's Guide
If possible, the serial output device you are connecting has to be set to Baud rate = 9600, Number of data bits = 8, No parity and 1 Stop Bit to match the default settings of the box. If this is not possible, you must change the functions 15, 16, 17 and 18 to match the settings of the serial output device.
For full details on the FSL functions (Y functions), see the " 5250 Programmer's Guide; Document No.: D62079.
The interface can be set up in many ways. From the factory, the interface has been set up to cover most needs and uses. Appendix B.: Test Printout is a sample printout of settings.
Keep the settings printout together with this manual for future reference.

Connecting to System ida FS 250, Operator's Guide
If the printout format does not match the test printout in Appendix B. or if nothing was printed, this means that the printer setup does not match the protocol converter setup. Contact your systems support personnel or your i-data dealer.
After a successful test printout has been generated to establish that the connection between the ida FS 250 converter and the printer is working correctly (see previous section), you are now ready to connect the ida FS 250 to the system.
All connections to the ida FS 250 protocol converter should be made while the power is switched OFF.
If the CU indicator does not turn ON, this means that there is no communication with the control unit. You should check the follow ing:
a. The twinax cable connection from the control unit to the ida FS 250.
b. The control unit (is it powered up etc.)
c. Is the control unit supported by the ida FS 250 ?
(See the section. Supported Control Units, for a list of supported control units).

Connecting to System ida FS 250, Operator's Guide
If all three (a. b. and c.) are in order, contact your systems support personnel or your point of purchase.
The test printout pages can be generated in two ways - via the address switch or via the line activating the T function . For details on the T function, please see the section: Quick Reference Guide of the Supported FSL Functions.
Keep the settings printout together with this manual for future reference.
Finally, a settings printout can also be generated at power on by activating function Y120. See the Section: Quick Reference Guide of the Supported FSL Functions for details.

Connecting to System ida FS 250, Operator's Guide
The ida FS 250 enables printer sharing between the system and a PC. For this purpose it is possible to specify a timeout period.
If the printer is receiving input on the parallel port, for example, and there is a break in the transmission of data, the other input ports will not be polled for the period specified.
The factory default timeout is 20 seconds. The timeout may be changed to suit your requirements. This is done by sending a new setup to the ida FS 250 input port where you want it to take effect.
When specifying the timeout it is also possible to specify a user string. A user string may be used for changing from one symbol set (e.g. Roman 8) to another (e.g. IBM-PC8), for example.
On the parallel and RS input port, you have to pro gram the required setup yourself.
For more detailed information on the commands required, see the chapter: Specifying Share Timeout and String.

Specifying Share Timeout and String ida FS 250, Operator's Guide
The ida FS 250 top panel has been designed to register the operation of the box via the four following indicator LEDs :
The CU indicator has 3 states which signal the following:
State Indication ON Contact with the control unit. BLINKING In test mode. OFF No contact of the control unit, or the contact has been broken for more than 1 minute.
The indicator LED has 2 states:
State Indication ON Indicates that the box is processing data from the Centronics parallel port OFF Indicates that the box is idle or processing data from the twinax/RS232 inputs

Specifying Share Timeout and String ida FS 250, Operator's Guide
The indicator LED has 3 states
State Indication ON Indicates that the box is processing data from the RS- 232 Serial input BLINKING Indicates that the box has defined the RS-232 as output for the box. OFF Indicates that the box is idle or is processing data from the twinax/Centronics inputs.
The indicator LED has 3 states:
State Indication ON Indicates that the connected printer is ready; i.e. that printer's "Select" condition is active and the "PE" signal is inactive. If the connected printer is an RS 232 printer, the ready validation is done by the "DTR" signal. BLINKING The printer is not ready and print may be pending in the buffer. OFF Indicates that the connected printer is not ready for data input.

Specifying Share Timeout and String ida FS 250, Operator's Guide
In order to specify the timeout for a specific input port, an FSL ( Function Selection via the Line) sequence must be sent to the port in question. To do this a temporary Escape (ESC) Character must be defined first. This is done in the following way:
The sequence "&&??%" will define " %" as the ESC Character.
Timeout is specified in FSL Function 100 . This function has the following syntax ("%" is the ESC Character):
Factory default = 20 seconds
User string: Optional - string in HEX to be sent to the printer before transmission of data, when the printer is selected by the share unit. If function 100 is sent to the twinax, a user string number can be defined instead of a HEX string. The user string then has to be defined in function 61.
The user string and settings will only be sent if a share condition has occurred.
The new setup must be saved in the NVRAM with the following command ("%" is the ESC Character):
&&?? · %Y100,[,user string]%

Specifying Share Timeout and String ida FS 250, Operator's Guide
The FSL string above was split up into several lines for reasons of clarification to simplify the explanation of the different functions. Below is an example where the FSL string is typed in one line.
Example:
The FSL string above has the following effect:

IPDS Setup ida FS 250 PDS, Operator's Guide
idaSetup is a program developed with the purpose of setting up the wide range of IPDS protocol converters via a PC share port or from a host.
For details on how to configure the IPDS parameters for the ida FS 250 PDS using the program idaSetup, see the separate documentation for this, “IPDS Programmer’s Guide”, doc. no. D60253. The manual is available as an electronic document.

Programming ida FS 250, Operator's Guide
This section describes how to recover from various IRQ conditions.
The printer will recover from these conditions without loss of data as long as you do not power off the printer.
The ida FS 250 PDS will detect if the printer is NOT READY and will interrupt data transmission to the printer. If the printer is OFFLINE (i.e. not READY) there will be no data loss as long as you do not power off the printer.
This condition is indicated by the printer's front panel. If printing continues, the print quality may not be acceptable. There will be no loss of data as long as you do not power off the printer.
This condition is indicated by the printer's front panel. There will be no loss of data as long as you do not power off the printer
You should not power off the printer, unless you power off the box as well. If only the printer is powered off, unpredictable results may occur.

The ida FS 250 works using a large number of internal Setup Functions (FSL Functions). FSL setup functions can be sent either from your IBM system or from a PC.
When the protocol converter has been installed and connected to a printer, you may have to consider the use of these setup options.
The factory default setup will meet the demands of most host systems and users, and special programming is therefore normally not required.
However, special circumstances may require changes in the pro gramming of the box. For full details on this please see the "5250 Programmer's Guide; D62079". In the Programmer's Guide you will find an extensive description of the FSL Functions with notes, comments and examples.
No escape character is defined when you receive the ida FS 250 from the factory. When you send FSL Functions via the data stream, the functions must be "separated" from the data stream, so that they are not printed. For this you need to define an Escape (ESC) Character.
The ESC Character tells the interface that the characters following the ESC Character in the data stream are to be regarded as a command. The command string must also end with the ESC Character .
Before you define the ESC Character please note the following:

The ESC Character may be defined as a temporary as well as a permanent ESC Character.
Below see how to define "%" as a temporary ESC Character.
Defining "%" as a temporary ESC Character.
Since the temporary ESC Character is defined in the temporary memory (RAM) alone, it is only in effect as long as the printer is switched on - or until you remove it again. To remove it you define it as "space".
Removing the temporary ESC Character
The special sequence that the interface will interpret as an FSL Function as shown below:
Syntax of an FSL Function. "%" is the defined ESC Character
The error message "Invalid Escape Sequence" will be printed on paper if an invalid escape sequence has been sent to the printer.
Recovery: Locate and correct the error in your setup file.
&&??% · &&?? · %Y,%

Y2 LPI Y3 CPI Y8 LU1 Language Y10 Page Format Y11 Paper Path Y12 Paper Size Y15 Baud Rate for Serial Input Y16 Number of Data Bits for Serial Input Y17 Parity for Serial Input Y18 Number of Stop Bits for Serial Input Y19 Duplex Printing Y21 Horizontal Compression and Vertical Scaling Y24 Interface selection Y48 Permanent Escape Character Selection Y51 User Defined String(s) at Power Up Y59 Bar Code Type Definition Y61 Setup for User Defined Strings Y62 Setup for IBM Defined Strings Y73 Select Translate Table Y74 Printer Symbol Set Definition Strings Y75 Overwrite Translate Table Y88 Physical Margin Y89 Physical Margin Compensation Y90 Define User Escape String Y91 Font Definition Y92 Font Point Size Definition String Y93 Font Attribute Definition String Y94 Font Typeface Definition String Y96 Font Change Simulation Y97 GFID/Font Selection Y98 Automatic Page Orientation Y100 Printer Share String and Timer Y119 Autoconfiguration Select Y120 Settings Printout at Power Up Y249 Enter Engineering Mode T Initiate Test T1 On-line Hex Dump T3 ASCII Hex Dump T4 Settings Printout T5 Printout Translate Table T6 Cancel ASCII Hex Dump

X Save/Overwrite Settings X1 Store Settings in Permanent Memory X3 Restore Factory Default Settings X4 Restore Settings from Permanent Memory Z Send User String S Send User String W Send Bar Code (as defined in Y59) P Program Flash Prom
%% Special transparent feature (Multiple paired Hex transparent). e.g.: %%1B45% where % is the defined ESC character.
% Special transparent feature (Single paired Hex transparent). where % is the defined ESC character.

In this section the supported FSL Functions in twinax will only be described with their syntax and parameters.
The notation below will apply to the following FSL Functions table:
% is the defined escape character
< > mandatory parameter which must be defined
[ ] optional parameter which can be defined
* factory default

No. Name Syntax Parameters 2 LPI %Y2,% 3 = 3 LPI 4 = 4 LPI *6 = 6 LPI 8 = 8 LPI 3 CPI %Y3,% 5 = 5 CPI *10 = 10 CPI 12 = 12 CPI 15 = 15 CPI 16 = 16.7 CPI 8 Language %Y8,% **37 = Engl. US EBCDIC 256 = International 273 = Austrian/ German 274 = Belgian 275 = Brazilian 276 = Canadian French 277 = Danish/ Norwegian 278 = Finnish/ Swedish 280 = Italian 281 = Japanese (Latin) 282 = Portuguese 283 = Spanish 284 = Spanish Speaking 285 = English (UK) 297 = French *500= Multinational 871 = Iceland
* EU default ** US default

No. Name Syntax Parameters 10 Page Format %Y10,[,n2]% n1 0 = Portrait 1 = Landscape *2 = COR 82 = COR regardless of Print Quality
n2 1 = Tractor 2 = Tray 1 3 = Drawer 2 4 = Manual feeder 5 = Envelope feeder 6 = Tray 3 11 Paper Path %Y11,% 1 = Tractor *2 = Tray 1 3 = Drawer 2 4 = Manual feeder 5 = Envelope feeder 6 = Tray 3

No. Name Syntax Parameters 12 Paper Size %Y12, [,n2,n3]%
n1 (Physical paper size) *1 = A4 2 = Legal 3 = Letter 4 = Executive 5 = Letter (Monarch) 6 = Business 7 = International DL 8 = International C5 10 = A3 11 = Ledger 99 = Use system SPPS or SHF/SVS values
n2 (Tray) 1 = Tractor
2 = Tray 1 3 = Tray 2 4 = Manual feeder 5 = Envelope feeder 6 = Tray 3
n3 (Validation paper size) *1 = A4 2 = Legal 3 = Letter 4 = Executive 5 = Letter(Monarch) 6 = Business 7 = Internat. 8 = Internat.C5 10 = A3 11 = Ledger 15 = Comm 9 Envel. 16 = B5 Envelope

No. Name Syntax Parameters 15 Baud Rate for RS232 inter- face
%Y15,% n1 0 = 300 baud 1 = 600 baud 2 = 1200 baud 3 = 2400 baud 4 = 4800 baud *5 = 9600 baud 6 = 19200 baud 16 Number of Data Bits
%Y16,% n1 7 = 7 bits *8 = 8 bits 17 Parity %Y17,% n1 0 = odd parity *1 = no parity 2 = even parity 18 Number of Stop Bits
%Y18,% n1 *1 = 1 stop bit 2 = 2 stop bits 19 Duplex Printing
%Y19,% *0 = Simplex 1 = Long-edge duplex 2 = Short-edge duplex 21 Horizontal Compression & Vertical scaling
%Y21,[,n2,n3]% n1 0 = Compression *1 = No compression
n2 1 = Tractor - Tray 1 2 = Drawer 1 3 = Tray 2 4 = Manual feeder 5 = Envelope feeder 6 = Tray 3
n3 1-255 = Vertical scaling in % *100 22 Printer driver selection
%Y22% 2 = HP PCL 4 *4 = HP PCL 5 24 Interface Selection
%Y24% n1 *0 = Port 0 (Centronics out or Serial in) 1 = Port 1 (Serial out)

No. Name Syntax Parameters 36 Suppress IBM control codes
%Y36% *0 = Respect codes 1 = Suppress codes 37 IBM Printer Emulation Select
%Y37,n1,% n1 device address *3812 5224 5225 5256 4234 4245 (IPDS)
n2 secondary address 0-6 48 Permanent Es- cape Character Selection
'' = value can be entered by means of an apostrophe notation or: = HEX value of the character selected from the table
%Y48,''%

No. Name Syntax Parameters 51 User-Defined String(s) at Power-Up
%Y51,% 0-7 = One or more strings stated in the form: (n1),(n2) , (nx) in ascending order The strings must be pre- defined in FSL 61 59 Bar Code Type Definition
n1 Numeric value from 1-8 specifying the bar code no.
n2 22-39 = Bar code type
n3 Bar code height in inches with values from 1-255
n4 Horizontal expansion with values from 1-16
n5 Optional GFID number 61 Setup for User Strings
%Y61,,% n1 0-99 = User Strings supported n2 00-FF = Hexadecimal string data 62 Setup for IBM defined strings
%Y62,n,% n string id number (0- 255)
string string contents in HEX and/or char. with apostrophe notation
For details on function, please see the 5250 Programmer's Guide, Doc. No.: D62079
%Y59,,, ,[,n5]%

No. Name Syntax Parameters 73 Select Trans- late Table
n1 (Translate Table) *1 = Roman-8 2 = IBM PC-8 3 = ECMA Latin 1 5 = US ASCII 6 = OCR A 7 = OCR B 8 = PC 850
n2 (Symbol Set) *1 = Roman-8 2 = IBM PC-8 3 = ECMA Latin 1 5 = US ASCII 6 = OCR A 7 = OCR B 8 = PC 850 *1-9 = Number of the translate table to be selected 74 Printer Symbol Set Definition Strings
%Y74,,% n1 1-8 = Symbol set no.
n2 00-FF = String contents in HEX apostrophe notation 75 User Defined Translate Table
n1 (EBCDIC) 40-FF = corresponds to position in translate table
n2 (Symbol Set) 00 = no change 01-08 = printer symbol set string no. as specified in Y74
n3 (ISO - in HEX) 00-FF = up to 16 bytes can be used
%Y73,[,n2]% · %Y73,% · %Y75, ,,%

No. Name Syntax Parameters 88 Physical Margins
n1 0 - +/-32000 = Horizontal margin compensation in 1/1440"
n2 0 - +/-32000 = Vertical margin compensation in 1/1440"
n3 0-2 = Orientation as defined in FSL 10 89 Physical Margin Compensation
%Y89,[,n2]% n1 *0 = No compensation 1 = Compensation as defined in FSL 88
n2 1 = Tractor 2 = Tray 1 3 = Tray 2 4 = Manual feeder 5 = Envelope feeder 6 = Tray 3 90 User Escape String Defini- tion
%Y90,,% n1 0 = Erase strings 01-FF = Hexadecimal user Esc. string no.
n2 = String contents in apostrophe notation.
%Y88,, [,n3]%

No. Name Syntax Parameters 91 Font Defini- tion
n1 (IBM GFID) 1-65535 = IBM GFID no.
See Appendix D. for more details on fonts
n2 (Typeface) 0-255 = Pre-program- med typeface value
n3 (Attribute) 0 = Remove all current attri- butes 1 = Bold 2 = Italic 3 = Bold and Italic 4 = Proportional 5 = Prop. Bold 6 = Prop. Italic 7 = Prop. Bold and Italic
n4 (Symbol Set) *1 = Roman-8 2 = IBM PC-8 3 = ECMA Latin 1 5 = US ASCII 6 = OCR A 7 = OCR B 8 = PC 850
n5 (Point Size) 1-255 = Point size
n6 (Translate Table) *1 = Roman-8 2 = IBM PC-8 3 = ECMA Latin 1 5 = US ASCII 6 = OCR A 7 = OCR B 8 = PC 850 92 Font Point Size Defini- tion String
%Y92,,% n1 10-255 = String no in decimal
n2 00-FF = String contents in HEX 93 Font Attribute Definition String
%Y93,,% n1 10-255 = String no in decimal
n2 00-FF = String contents in HEX
%Y90,,, ,, [,n6]%

No. Name Syntax Parameters 94 Font Typeface Definition String
%Y93,,% n1 10-255 = String no in decimal
n2 00-FF = String contents in HEX 96 Font Change Simulation
%Y96,% 1-65535 = GFID no.
See Appendix D for details on scalable fonts
%Y97, n1>,:%
n1 1-65535 = GFID No.
n2 = String for 0° rotation
n3 = String for 90° rotation 98 Automatic Page Orientation (APO)
%Y98,[,n2]% n1 *0 = Activate APO 1 = Deactivate APO
n2 1 = Tractor
2 = Tray 1 3 = Tray 2 4 = Manual feeder 5 = Envelope feeder 6 = Tray 3 100 Port Sharing Option
%Y100,[,n2]% n1 0-255 = Timeout in seconds
n2 00-FF = Optional string in HEX to be sent to printer before transmission of data when printer is selected by sharing unit
97 GFID/Font Selection · *20

No. Name Syntax Parameters 119 Auto- Configura tion select
%Y119,% n1 *0 = Disable Auto- configuration
2 = Auto- configuration via PJL 120 Settings printout at power up
%Y120,n1% n1 *0= disable settings printout at power up 1= enable settings printout at power up 249 Enter Engine- ering Mode
%Y249,n1% n1 password (contact your local i-
data distributor) T Initiate Tests %T# 1= On-line hex dump 3= ASCII hex dump 4= settings printout 5= printout translate table 6= cancel ASCII hex dump X Save/ Overwrite Settings
%X# 1= store RAM in EEPROM 3= factory default to RAM 4= restore settings to power up defaults S Send User String
%Sn% 1-99 user strings may be sent Z Send User String
%Zn 1-8 user strings can be sent W Bar Code Printing
%W,,% n1 1-8 Bar code definition as defined in Y59.
Number or alphanumeric data to be printed in bar code. Data must not exceed one line
P Program Flash Prom
This function is only available in engineering mode (Y249)
n2 a-z,A_Z,0-9 · %P2,area_id, intel_hex_data%

In order to ease customization of the ida FS 250, FSL parameters for twinax input can be programmed directly via the interface's Centronics or serial (RS-232) port using the Engineering Function Y249.
The Engineering Function enables the system to detect whether FSL sequences on shareport are intended for twinax FSL input or for shareport setup and will direct the sequences received to the twinax FSL interpreter.
The sequence works as a switch for FSL sequences. The defined Escape Character will also be translated and defined as Escape Character for the twinax FSL module. Function Y 249 is automatically deactivated after timeout on the shareport (i.e. settings defined in Y249 cannot be saved in the NVRAM).
The setup sequence must only contain ASCII characters. Apostrophe notation can be used if characters are included in the US ASCII 7 bit character set. All other data must be in HEX notation.
All functions which are accessible from the twinax input can be used via Centronics/RS-232 setup.
Before the Engineering Function can be activated, an Escape character must be defined:
The sequence "&&??%" will define "%" as the ESC Character.
&&??

If you have defined % as Escape Character, you activate the engi neering function by typing:
n = password. As this is sensitive information, system operators can contact point of purchse for password details.
The function will be deactivated automatically after timeout on the share port (timeout is defined in Y100 Port Sharing Option). See also the chapter: Specifying Share Timeout and String.
Unprintable characters (i.e. the escape character) must be defined in HEX notation if they are to be part of the setup print job. Only the FSL sequences are allowed.
The ida FS 250 firmware (complete firmware) may be updated either via the twinax line or via centronics input port. For further in formation please contact your i-data distributor.
If errors are detected, the downloading will be terminated and an error message will be printed if possible. If serious errors occur during programming, the firmware has to be downloaded via the share port.
The downloading of firmware is considered complete if no data is received within 30 seconds. The interface will then make a soft re set.
NOTE: In case of damaged FLASH PROM, try the following procedure: Boot Download of firmware: 1. Turn the power off 2. Place the rotary switch in the “B” position 3. Turn the power on and note that the READY LED is lit 4. Download the boot firmware (Syntax: “Copy 140.xxx.1 /b”) 5. Download the new firmware. When download is completed and the FLASH PROM is programmed, the LED will start flashing 6. Turn off the power and set the rotary switch in a position different from “A”, “B” or “T” before turning on the power again.
%Y249,n%

Error Messages ida FS 250, Operator's Guide
Printer-related error messages will be displayed on the printer front panel. To recover from these errors, please refer to the relevant printer documentation.
The following errors are related solely to the ida FS 250 and will appear as printed error messages. For some of the error messages, additional explanatory text may be printed out together with the error message.
Error 8008 - Attention ! Two devices on the same address
Escape Sequence Error Invalid ESC sequence has been sent to the printer (see the section: Invalid Escape Character)
Error 4510 Invalid SCS Control received
Error 5004 Initializing NVRAM
Error 5005 NVRAM failed
Error 5006 NVRAM initialized
Error 50?? CP Error
In addition to the above messages, a number of Boot Error Messages may be generated.
If two devices on the same twinax line has the same address, the printer will print an error message. To recover follow these steps:

Appendix Section ida FS 250, Operator's Guide
The following connections are available in the serial plug:
pin 1: N.C. pin 2: RX data pin 3: TX data pin 4: DTR pin 5: GND (signal) pin 6: DSR (busy) pin 7: RTS (always high) pin 8: N.C. pin 9: N.C.

Appendix Section ida FS 250, Operator's Guide
ida FS 250 Firmware version: S20 140.010/00970005 i-data international a-s Vadstrupvej 35-43 2880 Bagsvaerd, Denmark Phone: +45 44366000 Fax: +45 44366111 Boot id: 80023102 HW id: Current escape code = 00 in hexadecimal as Character = ' ' Dipswitch: National character set = Multinational Line Set Up: Addr. 0 3812 model 1.
4 *IPDS Function 2: Default LPI 6 Function 3: Default CPI 10 Function 8: Default codepage Multinational Function 10: Default orientation = COR Function 11: Default paperpath Drawer 1 Destination 2 Function 12: Papersize A4 Function 15: Baud rate: 9600 Function 16: Databits: 8 Function 17: Parity: None Function 18: Stopbits: 1 Function 21: Horizontal compression = OffLine spacing 100% Function 22: Print driver: PCL 5 Function 24: Output Source: 0 Function 36: Suppress SCS Controls: 0 Function 48: Permanent escape code: None Function 51: User strings at power on: None Function 59: Barcode definitions: None Function 61: User strings: None Function 62: Setup strings: None Function 73: Translate table: 1 ROMAN 8 Function 74: Symbol set def.: None Function 88: Physical margins: -288, -480 -288, -480- 288, -480 Function 89: Physical margin comp. = Off Function 90: User Esc. strings: None Function 91: User defined font translation table: None Function 92: Point size strings: None Function 93: Attribute strings: None Function 94: Typeface strings: None Function 97: User GFID/font selection Function 98: Orientation select = Automatic Function 100: IBM mode definition: Timeout 20 Sec.
Centronics input definition: Timeout 20 Sec. RS232 input definition: Timeout 20 Sec. Function 119: Autoconfiguration = 0 Function 120: Settings Printout at Power up = Off Free bytes: 1851 Substitute character in hexadecimal = 60 Left margin in 1/1440" = 0 Indent margin in 1/1440" = 0 Right margin in 1/1440" = 19008 Paper width in 1/1440" = 19008 Paper depth in 1/1440" = 15840 Top margin in 1/1440" = 174 Line distance in 1/1440 = 240 Maximum print line = 66

Appendix Section ida FS 250, Operator's Guide
The factory default GFID Table below lists all the predefined fonts which are supplied with the interface GFIDs (GFIDs 1 - 399) 2.
Fonts with GFIDs above 400 (i.e. scalable fonts) are described in the section Scalable Fonts below.
For further details on defining fonts, please see the section: Quick Reference of Supported FSL Functions, Function Y91 and Y96. If more details on these FSL functions are required , you are referred to the Programmer's Guide (D62079).
In the following Default GFID Table, the Attribute, Symbol Set and Translate Table figures will refer to the following:
0 = No attributes 1 = Bold 2 = Italic 3 = Bold and italic 4 = Proportional 5 = Proportional bold 6 = Proportional italic 7 = Proportional bold and italic
1 = Roman 8 2 = IBM PC-8 3 = ECMA Latin 1 4 = Roman 8 5 = US ASCII 6 = OCR A 7 = OCR B 8 = PC 850
2If, for reasons of backward compatibility, you wish to reestablish the fonts > 400 in the default GFID table, please contact you i-data supplier.

Appendix Section ida FS 250, Operator's Guide
In the table below, an asterisk (*) after the GFID number denotes a simulated IBM GFID.
Translate Table 3* OCR B 0 0 7 12 7 11* Courier 3 0 1 12 0 12* Prestige 8 0 1 10 1 18* Courier 3 2 1 12 1 19* OCR A 0 0 6 12 6 38* Presentation 11 1 5 14 5 39* Letter Gothic 6 1 1 14 1 40* Letter Gothic 6 0 1 14 1 46* Courier 3 1 1 12 1 51 Courier 3 0 5 12 5 52 Courier 3 1 5 12 5 53 Courier 3 2 5 12 5 60 Letter Gothic 6 0 5 14 5 66* Letter Gothic 6 0 1 12 1 68* Letter Gothic 6 2 1 12 1 69* Letter Gothic 6 1 1 12 1 80 Prestige 8 0 1 10 0 85 Courier 3 0 1 12 1 86* Prestige 8 0 1 10 1 87* Letter Gothic 6 0 1 12 1 91* Letter Gothic Italic 6 2 1 12 1 95* Courier Italic 3 2 1 10 1 109* Letter Gothic Italic 6 2 1 12 1 110* Letter Gothic 6 1 1 12 1 111* Prestige 8 1 1 10 1 112* Prestige 8 2 1 10 1 115 Courier 3 1 1 10 1 116 Courier 3 2 1 10 1 117 Prestige 8 0 5 10 5 118 Prestige 8 0 5 10 5 119 Prestige 8 2 5 10 5 204* Letter Gothic 6 0 5 12 5 221* Prestige 8 0 1 7 1 223* Courier 3 0 1 8 1 230* Letter Gothic 6 0 1 9 1 252* Line Printer 0 0 1 8.5 1 253 Line Printer 0 0 1 8.5 0 255 Letter Gothic 6 0 1 9.5 1 256 Prestige 8 0 5 7 5 Default GFID Table for GFIDs 1 - 399

Appendix Section ida FS 250, Operator's Guide
The ida FS 250 allows GFID access to all the scalable fonts found in the printer. These GFIDs are in the range 400 - 65535.
Typeface, typeface attributes and point size have been linked together using the system described below.

where XXX = point size and YY = typeface + attribute
Possible typeface values are:

0 5 Times Roman 4 4116 Coronet 10 4 Helvetica / Swiss 14 36 Helvetica Compressed 20 23 Century Schoolbook 24 4297 Mangold 30 17 Humanist / CG Optima 34 4168 Antique Olive 40 31 ICT Avantgarde 44 4197 Garamond Antique 50 16901 Times New 54 16602 Arial 60 52 Univers
Possible attribute values are:

Style Strokeweight 0 Medium upright 1 Bold upright 2 Medium italic 3 Bold italic

Appendix Section ida FS 250, Operator's Guide
This is 48 point, Helvetica Compressed, bold upright
This is 13 point, Times Roman, bold upright
Other relationships between IBM GFID and printer typefaces/fonts can be programmed using Function 91 or 97 (See Programmer's Guide for more details on Function 97). GFIDs may be selected with the normal procedure or using Function 96.
Font examples

Appendix Section ida FS 250, Operator's Guide
Coax S/370 - 390 SCS ida LS 170 External For Centronics attached matrix printers S/370 - 390 SCS + AFP ida LS 270 External For Centronics attached laser printers ida FS 270 External For PCL printers S/370 - 390 IPDS ida FS 270 PDS External For PCL printers ida PDS 270x MIO Internal For HP MIO printers with HP PCL4 or higher ida PDS 270x Optra Internal For Lexmark Optra L, N, R and C series Twinax AS/400 SCS ida LS 150 External For Centronics attached matrix printers AS/400 SCS/DCA ida LS 250 External For Centronics attached laser printers ida FS 250 External For PCL printers AS/400 IPDS ida FS 250 PDS External For PCL printers ida PDS 250x MIO Internal For HP MIO printers with HP PCL4 or higher ida PDS 812-1x Optra Internal For Lexmark Optra L, N, R and C series

Appendix Section ida FS 250, Operator's Guide
Token Ring S/370 - 390 AFP ida PS 03 TR External For Centronics attached laser and matrix printers ida PrintServer 03 IOP TR Internal For Lexmark Optra L, R, N and C series ida PrintServer 03 MIO TR Internal For HP MIO printers with HP PCL4 or higher ida PS 03 NP TR Internal For IBM Network Printer series S/370 - 390 SCS + AFP ida PS 23 TR 270 External For Centronics attached laser and matrix printers ida PrintServer 23 IOP TR 270 Internal For Lexmark Optra L, N, R and C series ida PrintServer 23 MIO TR 270 Internal For HP MIO printers with HP PCL4 or higher ida PS 23 NP TR 270 Internal For HP MIO printers with HP PCL4 or higher AS/400 SCS/DCA ida PS 23 TR 250 External For Centronics attached laser and matrix printers ida PrintServer 23 IOP TR 250 Internal For Lexmark Optra L, N, R and C series ida PrintServer 23 MIO TR 250 Internal For HP MIO printers with HP PCL4 or higher ida PS 23 NP TR 250 Internal For HP MIO printers with HP PCL4 or higher AS/400 & S/370-390 IPDS ida PS 13 TR External For Centronics attached PCL printers ida PrintServer 13 IOP TR Internal For Lexmark Optra L, N, R and C series ida PrintServer 13 MIO TR Internal For HP MIO printers with HP PCL4 or higher ida PS 13 NP TR Internal For IBM Network Printer series Ethernet S/370 - 390 AFP ida PS 04 ETH External For Centronics attached laser and matrix printers ida PrintServer 04 IOP ETH Internal For Lexmark Optra L, N, R and C series ida PrintServer 04 MIO ETH Internal For HP MIO printers with HP PCL4 or higher ida PS 04 NP ETH Internal For IBM Network Printer series S/370 - 390 SCS + AFP ida PS 24 ETH 270 External For Centronics attached laser and matrix printers ida PrintServer 24 IOP ETH 270 Internal For Lexmark Optra L, N, R and C series ida PrintServer 24 MIO ETH 270 Internal For HP MIO printers with HP PCL4 or higher ida PS 24 NP ETH 270 Internal For IBM Network Printer series AS/400 SCS/DCA ida PS 24 ETH 250 External For Centronics attached laser and matrix printers ida PrintServer 24 IOP ETH 250 Internal For Lexmark Optra L, N, R and C series ida PrintServer 24 MIO ETH 250 Internal For HP MIO printers with HP PCL4 or higher ida PS 24 NP ETH 250 Internal For IBM Network Printer series AS/400 & S/370-390 IPDS ida PS 14 ETH External For Centronics attached PCL printers ida PrintServer 14 IOP ETH Internal For Lexmark Optra L, N, R and C series ida PrintServer 14 MIO ETH Internal For HP MIO printers with HP PCL4 or higher ida PS 14 NP ETH Internal For IBM Network Printer series
SOFTWARE S/370 - S/390 PRINT REDIRECTION ida HPR Host software For PCL or PostScript printers S/370 - S/390 AFP ida PSS MVS Host software For PCL or PostScript printers ida PSS VM Host software For PCL or PostScript printers ida RPPC NLM Server software For local or remote PCL printers ida RPPC AIX Server software For local or remote PCL printers ida RPPC HP UX Server software For local or remote PCL printers ida RPPC Windows NT Server software For local or remote PCL printers ida RPPC Sinix Server software For local or remote PCL printers

Reader's Comments ida FS 250, Operator's Guide
This manual is part of a library that serves as a reference source for programmers and operators of i-data equipment. This form may be used to communicate your view about this publication. Your in terest is appreciated.
Comments may be written in your own language, use of English is not required.
Documentation i-data international a-s Vadstrupvej 35-43 DK-2880 Bagsvaerd Denmark
or use our E-mail address at the Internet:
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.