MAXI-140 Opera tor’ s Man ual P/N 31033596_B 01 J une 2007 ™.
T hese merchandisers are manufactur ed to meet ANSI / National Sanita tion F oundation (NSF ® ) Standar d #7 T ype II requirements . Proper installa tion is required to maintain certifica tion. Near the serial pla te, each case carr ies a label identifying the type of application f or which the case was certified.
SAFETY FIRST! Bef ore installing, read and understand the opera ting manual. An y dama ge caused by not f ollow ing directions gi ven in this man ual is out- of-warr anty . Contact T o request technical assistance with y our Chill Chamber , or to place a serv ice call, please phone Hussmann ’ s call center at 1 (800) 504-4828.
Condensa tion ma y f orm on external parts w hen the merchandiser is used in high r ela ti ve humidity . Use a soft cloth to r emo ve moistur e . The floor or counter must be fla t to facilitate lev eling and to a v oid pr oblems w ith door seal- ing or a bnor mal noises .
©2007 HUSSMANN CORPORA TION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-504-4828 • WWW .CHILLCHAMBER.HUSSMANN.COM 3 P/N 31033596_B 01 J une 2007 ™ MAXI-140 Optional Leg Kit T o maintain NSF standards of cleana bility w hen sealing cannot be done , Hussmann offers optional leg kits tha t raises the MAXI-140 f our or six inches .
INST ALL SHEL VES The MAXI-140 comes standard w ith one f ixed w ire shelf w ith div iders f or 16oz. alumin um bottles and one remo v a ble fla t w ire shelf f or 16oz. alumin um bottles . The remo va ble lo wer shelf m ust be placed flush a gainst the back to maintain pr oper air flo w and pr oduct temperatur e .
SET Safe-NET TIME Safe-NET is the electr onic controller tha t regula tes the cooling system. Bef ore Safe-NET can opera te correctly , the internal clock must be set.
• Press and r elease the SELECT b utton until y ou are in the pr oper menu. Once in the pr oper men u press the UP or DO WN button to enter the men u and to scroll thr ough the men u. • Once a t the men u item that y ou want, pr ess the SELECT b utton until the item flashes between the v alue and the title .
• Once the displa y starts blinking y ou w ill be a ble to select the pass code , 595 . Press the DO WN button to get to this n umber . • Once 595 is displa yed, press the SELECT b utton on the Safe-NET displa y module . The displa y w ill re vert to cy cling between P ASS and 595 .
Set Defr ost Time (P ass Code Needed) • Press the SELECT b utton (top left button) until y ou see dEFr . • Then press the UP b utton twice to get to StAr and press SELECT . • Press the UP or DO WN b utton to change min utes; press SELECT . • Press the UP or DO WN b utton to change hours; press SELECT .
©2007 HUSSMANN CORPORA TION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-504-4828 • WWW .CHILLCHAMBER.HUSSMANN.COM 9 P/N 31033596_B 01 J une 2007 ™ MAXI-140 MAXI-140 MAXI-140 MAXI-140 MAXI-140 ™ Once the desired setting is displa yed, press the SELECT b utton to store the ne w value .
CARE AND CLEANING Long life and sa tisfactory perf or mance of an y equipment is dependent upon the care it recei ves . T o ensure long life , proper sanita tion and minim um maintenance costs , this unit should be thor oughly cleaned, all debr is remo ved and the interiors w ashed down.
Whenever possible, use all product bef ore per- forming maintenance. Product allo wed to warm abov e the operating temperature (22°F) may freeze when restock ed. R emov ing Shelves The MAXI-140 comes standard w ith one fix ed w ire shelf (upper) with d iv iders f or 16oz.
Condenser Coil T o maintain peak operating ef ficiency , use a soft hand brush or soft brush a ttachment on a vacuum to r emov e accumula ted dust fr om the coil a t least once each month. A dirty coil w ill slo w pr oduct cooling significantl y and can increase ener gy consumption by as m uch as 20%.
©2007 HUSSMANN CORPORA TION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-504-4828 • WWW .CHILLCHAMBER.HUSSMANN.COM 13 P/N 31033596_B 01 J une 2007 ™ MAXI-140 8. T o remo ve the fluorescent lamp , disconnect the tw o indiv idual connectors fr om each end.
©2007 HUSSMANN CORPORA TION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-504-4828 • WWW .CHILLCHAMBER.HUSSMANN.COM 14 P/N 31033596_B 01 J une 2007 MAXI-140 OPERA TING TIPS • The unit m ust be allo wed to stand in place f or 30 min utes bef ore it is plugged in.
TR OUBLESHOOTING The f ollow ing chart identif ies most common pr oblems , their causes , and suggested solutions . ©2007 HUSSMANN CORPORA TION • BRIDGETON, MO 63044-2483 U.
HUSSMANN CORPORA TION Limited W arranty for Chill Chambers in the United States & Canada T his warranty is made to the original user a t the original installa tion site and is not transfera ble .
P A TENT W ARRANTY Hussmann warrants that its pr oducts do not infringe the claims of an y existing United States pa tent, but Hussmann makes no warranty against infr ingement b y reason of the use thereof either in combination with other pr oducts or in the operation of any pr ocess or use of products other than f or their intended pur pose.
22 F.
An important point after buying a device Hussmann MAXI-140 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hussmann MAXI-140 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hussmann MAXI-140 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hussmann MAXI-140 you will learn all the available features of the product, as well as information on its operation. The information that you get Hussmann MAXI-140 will certainly help you make a decision on the purchase.
If you already are a holder of Hussmann MAXI-140, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hussmann MAXI-140.
However, one of the most important roles played by the user manual is to help in solving problems with Hussmann MAXI-140. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hussmann MAXI-140 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center