Instruction/ maintenance manual of the product CERATRONIC Proximity Faucet with Touch-Free Temperature Control American Standard
Go to page of 11
Installation Instr uctions Installation Instr uctions (In T oronto Area onl y: 1 -905-3061 093) CERA TRONIC™ Pr oximity F aucet with T ouch-F ree T empera ture C ontrol T o lear n more about American Standard F aucets visit our websit e at: www .us.
5. 4" Deck plate ( optional m ust be ordered separ ately ) 6. 8" Deck plate ( optional m ust be ordered separ ately ) 7 . Optional Remote Contr ol 8. Key f or vandal r esistant aerat or 1 .Ceratronic Spout Assembl y 2. Mounting Kit 3. Electrical Enclosur e 4.
9 7 10 8 T OOLS REQUIRED 1 Channel Locks 2 Adjust able W rench 3 Plumbers' P utty or C aulking 4 Phillips Scre wdriver 12 3 45 6 7 INS T ALL SPOUT A SSEMBL Y ; F ig. 1 INS T ALLA TION C A UTION T urn of f hot and cold water supplies befor e beginning 2 10' 1 R oughing-in Dimensions 1.
F ig. 2 1. Determine location of ENCLOSURE (1) . It must be located with-in the 1 4" (356mm) by 21" (533mm) shaded area sho wn in Fig. 2 in order f or electrical connections from the spout assemb ly t o be made. NO TE: ENCL OSURE SUPPL Y HOSE is 20".
4 ELECTRIC AL 1 ELECTRIC AL INST ALLA TION 2 10 9 3 5 5 6 6 7 7 8 8 F ig. 1e F ig. 1d F ig. 1f 11 12 1 2 15 1 5 14 1 4 F ig. 1g F ig. 1h F ig. 1k 13 11 1 1 1 F ig. 1c 1. Remo ve ENCL OSURE CO VER (1). F ig. 1 . 2. Remo ve CIRCUI T BOARD (2) from ENCL OSURE (3) .
OPER A TION When the Sensor det ects a user , the water immediatel y star ts to f low . W ater flo w will stop T wo seconds af ter user is out of sensor range . The of f dela y allows the user t o comfor tab ly mov e his hands without the flo w cycling on t o off .
MAINTENANCE Note: The fact or y set ting of the Default T emperature is at a position of e ven amounts of hot and cold wat er flo ws. This set ting can only be changed within the fir st 1 5 minutes of s witching on the power . 1. R emo ve th e po we r t o th e f auc et by un plug ging the Po w e r S u p p l y f r o m t h e w a l l o u t l e t .
7 1. Remo ve ENCL OSURE CO VER. 2. Close SUPPL Y ST OPS. Note: K eep water f lowing out of f aucet while shut ting off . 4. Unthread S TRAINER (1) using a 7/1 6" socket. 5. P ull out the STRAINER (1) and clean with an old toothbrush. Rinse thoroughly with w ater .
FA Q ' S Q: Wh y has the flo w rate of the f aucet reduced significantl y? A: Check and clean aer ator and strainer . Q: Wh y do I here humming noise fr om under the deck af ter f aucet is tur ned of f? A: The humm ing nois e i s the te mpe r tur e con tro l m oto r .
605P400 605P800 9 CERA TRONIC LA VA TORY FAUCETS CHROME 002 Replace the "YYY" with appropriate finish code HOT LINE FOR HELP For toll-free information and answers to your questions, call: 1 (800) 442-1902 W eekdays 8:00 a.m. to 8:00 p.m. EST IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093) W eekdays 8:00 a.
M968857 REV .1 .2.
An important point after buying a device American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control you will learn all the available features of the product, as well as information on its operation. The information that you get American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control will certainly help you make a decision on the purchase.
If you already are a holder of American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control.
However, one of the most important roles played by the user manual is to help in solving problems with American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device American Standard CERATRONIC Proximity Faucet with Touch-Free Temperature Control along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center