Instruction/ maintenance manual of the product 8203 Hunter Fan
Go to page of 18
1 42935-01 06/04/2007 Installation Guide Energy Star Bath F an Models 82030, 82031, & 82032 READ and SA VE THESE INSTRUC TIONS ENGLISH See page 2 ESP AÑOL Vea la pág ina 19.
2 42935-01 06/04/2007 1) Read all instructions before attempting to install or use this appliance. T his appliance is for general ventilating use only .
3 42935-01 06/04/2007 6) Never place a switch where it can be reached from a tub or shower . Do not install this appliance in a tub or shower enclosure. 7) Installation work and electrical wir ing must be done by qualified person(s) in accordance with all applicable codes and standards, including fire -rated construc tion codes and standards.
42935-01 06/04/2007 4 F G H I L M x2 N x3 * * A B C 95044-01-000 97128-01-000 03242-07-133 97118-01-000 x2 D 97517-01-000 74508-03-133 Mounting Rails Housing Wiring Co ver F an Assembly 3/8” Cable Connector Bezel Wiring Co ver Screw Check all the parts.
42935-01 06/04/2007 5 Loosen the wiring cover screw. Remove the fan assembly from the housing. Remove the wiring cover . D E C Choose Installation Option F or New Construction - attaching to joist, go t o step A1, page 5. F or New Construction - suspended between, joists go to step B1, page 7.
42935-01 06/04/2007 6 A 1 Sec tion A - New Construc tion - attaching to joist Drive mounting screws (supplied) into joist or framing. Position the correct depth mark at the bottom edge of the joist based upon the the thick ness of your sheetrock. 5/8 1/2 5/8 1/2 A 2 Pop out a wiring access slug.
42935-01 06/04/2007 7 A 6 Connect 4” duct and vent to the outside. Use duct tape to secure joints. If duc ting does not fit securely , an adapter may need to be purchased. Go to Section E - Final Installation on page 14. Sec tion B - New Construction – suspended between joists Pop out a wiring access slug.
42935-01 06/04/2007 8 Mark position of screws by using holes as a template. Drill a pilot hole at the TOP of each outline. B4 1/16” bit B5 Inser t mounting screws, leaving space between the screw head and the joist. (Screws are supplied.) Attach the rails onto the screws.
42935-01 06/04/2007 9 B10 Install the wir ing and the strain relief into the wiring access hole you made earlier . B11 Connect 4” duct and vent to the outside. Use duct tape to secure joints. If duc ting does not fit securely , an adapter may need to be purchased.
42935-01 06/04/2007 10 Slide the mounting rails into brackets . C3 5/8 1/2 5/8 1/2 C4 Using the depth markings on the housing, position the bottom edge of the housing so that it will be flush with the sheetrock. Pop out a wiring access slug. C6 C5 Mark position of screws by using holes as a template.
42935-01 06/04/2007 11 C7 Inser t mounting screws, leaving space between the screw head and the joist. (Screws are supplied.) Attach the rails onto the screws. C8 C9 Tighten screws . 3” C 1 0 Run the power supply wire through the strain relief , leav- ing 3” between the end of the wire and the strain relief .
42935-01 06/04/2007 12 Go to Section E - Final Installation on page 14. Sec tion D - Existing Construction – accessible from below Remove one of the wiring access slugs on the top of the housing.
42935-01 06/04/2007 13 Connect 4” duct and vent to the outside. Use duct tape to secure joints. If duc ting does not fit securely , an adapter may need to be purchased. Install the wir ing and the strain relief into the wiring access hole you made earlier .
42935-01 06/04/2007 14 E2 E 3 Connect fan wiring harness. DO NOT ALLOW THE F AN TO HANG FROM THE WIRING HARNESS. Install the wir ing cover box. M ake sure all wiring connec- tions are inside the wiring cover box.
42935-01 06/04/2007 15 E7 E8 Install the bezel by inser ting the wire clips into the tabs on the inside of the housing. Complete . E9 Restore power at the source.
42935-01 06/04/2007 16 T rouble Shooting Pr oblem: F an does not come on. Solution: • T urn power on, r eplace fuse, or reset br eaker . • Hunter F an Bath V entilators are extremely quiet. T o conrm that the fan is running, place your hand near the vents to f eel the air movement.
17 42935-01 06/04/2007 Hunter F an Company Bath F an LIMITED W ARR ANT Y Hunter F an Company makes the following limit ed warranty to the original user or consumer purchaser of this Hunter Bath F an: .
42935-01 06/04/2007 18.
An important point after buying a device Hunter Fan 8203 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hunter Fan 8203 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hunter Fan 8203 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hunter Fan 8203 you will learn all the available features of the product, as well as information on its operation. The information that you get Hunter Fan 8203 will certainly help you make a decision on the purchase.
If you already are a holder of Hunter Fan 8203, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hunter Fan 8203.
However, one of the most important roles played by the user manual is to help in solving problems with Hunter Fan 8203. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hunter Fan 8203 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center