Go to page of 32
.
Contents Descriptio n Page Introduct i o n3 W arrant y3 Hea l th and Sa f et y4 Mach i ne Car d4 Genera l Sa f ety In s truct i on s5 Re f r i gerant R134a Sa f ety Dat a6 In s ta ll at i o n8 In s ta.
I m portant The re f r i gerant a v a il ab l e on the C s er i e s o f Co m pre ss ed A i r Dryer s i s Refrigerant R134a or Refrigerant R407C . It i s im perat i v e that re f r i gerant s are not mix ed.
Health and Safety Due regard s ha ll be g i v en to ob s er v i ng s a f e procedure s w hen w ork i ng w i th or on the equ i p m ent. It i s the re s pon s i b ili ty o f the In s ta ll er / Operato.
General Safet y Instructions IMPOR T A N T : T HE FOLLO W ING S A FE T Y PREC A U T IONS MUS T BE RE A D A ND UNDERS T OOD BEFORE REP A IR OR M A IN T EN A NCE W ORK IS A TT EMP T ED. Ge n e r al Be w are o f the f o ll o w i ng danger area s w i th i n the dryer : a) Any rotat i ng co m ponent s ( f an etc.
Refrigerant Safet y Data Reactivity Data Un s tab le Stab ili ty Stab l e YES Conditions to A void U s e i n pre s ence o f naked f l a m e s , red-hot s ur f ace s .
Health Hazard Data and First A id Short term effects of over exposure when: In contact w i th s k i n: L i qu i d s p l a s he s m ay cau s e f reeze burn s . No i n f or m at i on f ound on i rr i tancy or s en s i t i s at i on. There i s no kno w n hazard due to ab s orpt i on through the s k i n.
Installation - General St o r a ge The equ i p m ent s hou l d be s tored i n a s ecure f ro s t f ree area w i th a m a xim u m a m b i ent o f 55°C and m a xim um hu mi d i ty o f 90% non-conden s i ng.
Installation - Electrical The C s er i e s Dryer s requ i re a 220/240 Vo l t 1 pha s e and neutra l 50-60 Hz s upp l y. A f l y i ng l ead i s i n s ta ll ed on the dryer f or con v en i ence.
Co mm issioning The un i t s are f actory pre- s et and co mmi ss i oned and s hou l d not need any f i e l d ad j u s t m ent. Ho w e v er, i f a f ter a per i od o f t im e the un i t i s f ound to .
PS1061-C-021.
PS1061-C-001.
PS1061-C-002.
PS1061-C-003.
PS1061-C-004.
PS1061-C-005.
T echnical Description of Co m ponents 1. C o m p r ess or Th i s i s a f u ll y her m et i c, h i gh back pre ss ure s i ng l e pha s e type; the i nterna l co m ponent s be i ng m ounted on s pr i ng s to mi n imi s e v i brat i on.
T echnical Data T able Mode l C9- 1 C14- 1 C19- 1 C31- 2 C39- 2 C58-2 No mi na l A i r f l o w † m 3 / mi n 0.5 8 0.8 3 1.1 6 1.8 3 2.3 3 3.5 No mi na l Pre ss ure Dro p ba r 0.
T echnical Data T able Mode l C92- 3 C120- 3 C147- 3 C175- 4 C238-4 No mi na l A i r f l o w † m 3 / mi n 5. 5 7.1 6 8.8 3 10. 5 14.33 No mi na l Pre ss ure Dro p ba r 0.
Electrical Description Desc r i p ti o n o f C o m po n e n ts 1 . "ON / OFF" Switch Th i s sw i tche s the li v e s i de o f the po w er s upp l y to the c i rcu i t.
Wi r i n g Dia g r a ms To a ss i s t under s tand i ng o f the e l ectr i ca l c i rcu i try the f o ll o w i ng w i r i ng d i agra m s are i nc l uded: Model Number s Schematic W iring Diagram Numb.
PS1061-C-011.
PS1061-C-012.
PS1061-C-013.
PS1061-C-014.
Control of Refrigerant Discharge By i nternat i ona l agree m ent, the w or l d w i de u s e o f certa i n re f r i gerant s w ill be reduced i n s tage s .
Routine M aintenance It i s not nor m a ll y nece ss ary to open the re f r i gerant c i rcu i t. I f a prob l e m i s s u s pected i t i s s trong l y reco mm ended that un i t m a i ntenance or repa i r i s undertaken by a CITY & GUILDS 2078 (or equ i v a l ent) COMPETENT REFRIGERATION ENGINEER.
Fault Finding The f o ll o w i ng f au l t f i nd i ng chart re l ate s v ar i ou s s y m pto m s and f au l t s o f the re f r i gerat i on s y s te m.
Fault Finding continued PROBLE M C A US E SYMP T O M REMEDY Co m pre ss ed a i r f l o w rate too h i gh. Pre ss ure do w n s trea m f rom the dryer l o w er than the e x pected v a l ue. Reduce the co m pre ss ed a i r f l o w rate. Conden s ate i s Frozen .
Fault Finding continued PROBLE M C A US E SYMP T O M REMEDY Fan m otor s top w ork i n g E v ery LED at e l ectron i cs contro l board doe s n’t li ght so i t s s imil ar to no e l ectr i c in c i r.
Notes.
Denco Li m ited - General Infor m ation Denco Limited Head O ffice Do l ph i n Hou s e, M oreton Bu si ne ss Par k, M oreton-on-Lugg, Hereford, HR4 8DS, UK.
An important point after buying a device HUGFEN C39-2 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought HUGFEN C39-2 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data HUGFEN C39-2 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, HUGFEN C39-2 you will learn all the available features of the product, as well as information on its operation. The information that you get HUGFEN C39-2 will certainly help you make a decision on the purchase.
If you already are a holder of HUGFEN C39-2, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime HUGFEN C39-2.
However, one of the most important roles played by the user manual is to help in solving problems with HUGFEN C39-2. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device HUGFEN C39-2 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center