Instruction/ maintenance manual of the product rx1620 HP (Hewlett-Packard)
Go to page of 73
HP Int egr it y rx1 6 20 Maint enance Gui de HP P art Number: AB4 30 -9 60 1 4 P ublished: January 20 1 2 E dition: 3.
© Cop yr ight 2005, 20 1 2 Hew lett-P ack ard De velopmen t Compan y , L.P . The inf ormatio n contained her ein is subj ect to change w ithout no tice. T he only w arr anties f or HP produ cts and servi ces are s et forth in the e xpres s war ranty stat ements accompan ying su ch pr oducts and servi ces.
C ont ents 1 Abou t This Doc ument..................................................................................5 What’s in T his Doc ument..........................................................................................................
R emov ing and Replac ing the P CI I/O R iser Ass embly..................................................................50 R emov ing the PCI I/O R iser As sembl y...................................................................................50 R eplacing the P CI I/O Ris er Assembl y.
1 Abo ut T his Doc ument This doc ument desc r ibes ho w to maintain y our HP Integr ity rx1 6 20 Serve r , R egulatory Model Number : R S VL A-04 06. The doc ument prin ting date and part number indicate the doc ument’s c urr ent editi on . The pr inting date w ill change w hen a new editi on is pr inted .
IMPORT ANT : The latest v ersion o f this docume nt can be fo und online at http://www .hp .com/ bi zsupport . HP Encour ages Y our C omments HP encour ages your co mments concer ning this doc ument . W e ar e truly co mmitted to pr ov iding doc umentati on that meets y our needs.
2 Inst alling and C onf igur ing This c hapte r pro vide s infor mation r equir ed in installing additio nal components and co nfi guring the HP Integr it y rx1 6 20 Se r v er .
1 . R emov e the slot filler that is inst alled in slot 1 . CA UTION: If the HP Serv er is to be oper ated w ith only a single har d disk dr iv e installed, the har d disk dri ve slot f iller mu st be installed t o insure pr oper cooling .
Figur e 3 Disk Dri ve Installation in Slot 1 3 . Clo se the dr iv e -ej ector handle b y pushing it do wn until it c lic ks. 4. The har d disk dri v e is no w corr ectl y installed .
Inst alling Pr oces sor s and Memory This s ectio n pro vi des info rmatio n about inst alling proce ssor s and memory . T he proce ssor s and memory slots ar e located on the s y stem boar d , whi ch is acces sible by r emov ing the s y stem co v er .
Figur e 4 Proces sor Location 1 . R emov e the cov er . S ee “Remo ving and R eplac ing the Co ve r” (page 30) . 2 . R emov e the sheet metal air duct b y pulling it str aight up . 3 . If the CP U dust co v er is installed , r emo ve the du st co ver .
Figur e 5 Remo ving the Airflow Block er , CP U Dust Cov er , and Air Duct 5 . Unloc k the proce ssor -locking mec hanism using the spec ial pr ocessor t ool (P/N 5 06 9-544 1 ) , or equi valent 2 . 5 mm he x tool , shipped with y our r eplacement pr ocess or ass embly .
Figur e 6 Unlocking th e Pr ocessor Locking Mec hanism 6 . R emov e the pin cov er and pr otecti ve cap s for the ca ptiv e scr e ws o n the proce ssor . 7 . P lace the pr ocesso r and heatsink asse mbly o ve r the pr ocessor s ock et. U se the fo ur locator posts o n the assembl y to align w ith the locator hole s on the sy stem boar d.
8. Use the s pec ial pr ocess or tool (P/N 5 06 9-544 1 ) shipped with y our r eplacement pr ocessor ass embly to loc k the pr ocess or in place on the s y stem boar d. T o do this, ins ert the spec ial pr ocess or tool into the loc k and r otate it c lock w ise 1 80 degr ees.
Figur e 1 0 Connecting the Processor P o wer P od 1 1 . Ali gn the two mounting s cr e w holes on the po wer module w ith their sc r ew ho les on the s ys tem boar d’s metal mounting br ack et .
Figur e 1 1 Securing the Pr ocessor P ow er P od 1 2 . Connec t the po we r pod cable to the po we r connector o n the sy stem boar d. 1 6 Installing and C onfi guring.
Figur e 1 2 Connecting t he P ow er Cable 1 3 . Re install the sheet met al air duct . 1 4. R eplace the cov er . 1 5. V er ify that the new ly inst alled pr ocessor w orks: • R un the info cpu command at the EFI shell pr ompt , or • R un cpu diag fr om Offline Diagno stic CD f or full f uncti onal chec k.
Figur e 1 3 DIMM Loading Order DIMM Locati ons E ight DIMM slots ar e pro vided o n the sy stem boar d. T hese DIMM slots ar e designated in or der ed pairs . 0A and 0B, 1A and 1B , 2A and 2B , and 3A and 3B. DIMM si z es w ithin each pair m ust matc h.
Figur e 1 4 DIMM Locations Inst alling DIMMs T o install DIMMs , perfor m the follo wing s teps: Installing A dditional Memory 1 9.
1 . T urn o ff the sy stem , disconnect all ca bles, and r emov e the s y stem co ve r . CA UTION: T o ensur e that memory modules ar e not damaged dur ing r emo val or ins tallation , po we r off the serv er and unplug the po w er cor d fr om the A C pow er outlet .
6 . R eplace the cov er , reconnec t all cables, and tur n on the po w er . 7 . V er ify that the new ly ins talled memory wo rks: • R un the info mem command at the EFI shell pr ompt , or • R un memdiag fr om the Offline Di agnos tics CD to insur e that the memory is functi onal.
Figur e 1 6 Using J ackscrew t o Release PCI I/O Riser 3 . R emov e the PCI I/O R iser f r om the chas sis. 2 2 Installing and C onfi guring.
Figur e 1 7 Remo ving the PCI I/O R iser Assembly 4. R emov e the PCI slot co v er . Figur e 1 8 Remo ving a P CI Slot Cov er 5 . Gr asp the edges o f the PCI car d being installed and gentl y pr ess the connec tor int o the PCI I/O r iser connect or .
Figur e 1 9 Installing a PCI Car d 6 . Insert the car d mounting sc r ew and s ec ure w ith a T- 1 5 dri ver . 7 . R eplace the PCI I/O r iser a ssembl y by po sitioning the connec tor o v er the mating connecto r on the s y stem boar d and then tur ning the jacks cr ew to comple te the connecto r mating.
Figur e 20 Remo ving the MP Card Blank 5 . R emov e the insulator between the battery and the battery sock et on the management pr ocessor car d. 6 . Ali gn the MP card o ver the tw o mounting posts o n the sy stem boar d and align the thr ee connect ors of the MP car d with the c utou ts on the r ear panel.
Figur e 2 1 Connecting t he Management Processor Car d 1 0. Sc re w in the t w o e xternal moun ting posts that ar e located on both sides o f the 2 5-pin ser ial connect or .
Figur e 2 2 Installing the External Mounting P osts 1 1 . R eplace the sy stem co ver and r econnect the po w er and ext ernal cable s. Inf ormati on r equir ed to access , conf igur e and to utili z e the management pr ocess or is pr o vi ded in Chapt er 4, “Utiliti es, ” of the HP Integr ity rx 1 6 20 Oper ations Gui de .
3 R emo v ing and R eplac ing Co mpone nts This c hapte r pro vide s instru ctions f or remo ving and r eplac ing compone nts of the HP Integr it y rx1 6 20 Serv er .
Insert the Se r v er into the R ack T o insert the serv er into the r ack , perfo rm the f ollo wing s teps: 1 . Pr ess the r ail clips on e ither side of the s erver in w ard and pu sh the serve r into the r ack until it stop s. 2 . R eplace the T- 2 5 sc re ws that fa sten the se rver to the r ac k.
R emo ving and R eplac ing the C o v er CA UTION: Do not oper ate the server w ithout the co ver in place . Operati on of the se rver w ithout the co ver in place w ill result in s ys tem failur e. Oper ation of the se rver w ithout the co ver in place w ill mak e the server su sceptible to EMI and o ver heating proble ms.
1 . Ali gn the tabs on the co v er w ith the slots on the side s of the cha ssis. Figur e 25 Aligning the Co ver 2 . Clo se the cov er by mo v ing the latch handle c lock w ise .
R emo ving and R eplac ing S y ste m Memory S y stem memo r y DIMMs ar e located on the s yste m board . W ARN ING! Ensure that the s ystem is po wer ed-down and all po wer sources ha ve been disconnected from the server prior to r emov ing or replacing s ystem memory .
Inst alling S y ste m Memory T o install DIMMs , perfor m the follo wing s teps: 1 . Ali gn the DIMM with the s ock et located on the s yst em board . 2 . Gentl y and ev enly push on eac h side o f the DIMM until it seats in the soc ke t. Ensur e the e xtrac tion le v ers ar e in the clo sed positi on .
Figur e 2 9 Process or Location W ARN ING! Ensure that the s ystem is po wer ed-down and all po wer sources ha ve been disconnected from the server prior to r emov ing or replacing a proces sor . V oltages are present at v arious locations w ithin t he server whenev er an AC po wer sour ce is connected.
Figur e 30 5 . R emov e the t w o pow er pod mounting sc r ew s . Figur e 3 1 Remo ve the Process or P ower P od Mounting Screw s Re mov ing and Replac ing a Pr ocesso r 3 5.
6 . Disconnec t the pow er pod by sli ding the pow er pod to war d the r ear of the s y stem boar d. Figur e 3 2 Disconnecting th e Pr ocessor P ow er P od 7 . L ift the pow er pod up and out of the c hassis . P lace the po w er pod into an antis tatic con tainer .
Figur e 33 R emov ing the P ow er P od 8. R elease the f our capti ve s cr ew s on the pr ocess or . 9 . Unloc k the proce ssor -locking mec hanism using the spec ial pr ocessor t ool (P/N 09 90 1 -04 00 7) shipped w ith y our r eplacement pr ocess or ass embly .
Figur e 34 Unlock the Processor Sock et 38 R emov ing and R eplacing C omponents.
1 0. L ift the proce ssor up and o ut of the c hassis . P lace the proce ssor in to an antistati c container . Figur e 35 R emov ing the Processor R eplac ing a Pr oces sor Pr ocess ors ar e located on the s yste m board . T he sy stem boar d can support either one o r two pr ocess ors .
1 . T urn off the s ys tem and disconnec t all cables . 2 . R emov e the cov er . S ee “Remo ving and R eplac ing the Co ve r” (page 30) . 3 . Unloc k the proce ssor -locking mec hanism using the spec ial pr ocessor t ool shipped w ith yo ur r eplacement pr ocessor as sembl y .
Figur e 3 7 Loc king the Proces sor Assembly in P lace 6 . Use the s pec ial pr ocess or tool shipped w ith your r eplacement pr ocess or asse mbly to loc k the pr ocess or in place on the s y stem boar d .
Figur e 3 9 Installing the Processor 8. Slide the po wer module on the s yst em board me tal mounting br ack et so that the po wer module contac ts connect w ith the proces sor connec tor .
Figur e 4 1 Sec uring the Pr ocessor P ow er P od 1 0. Connec t the po we r pod cable to the po we r connector o n the sy stem boar d. Re mov ing and Replac ing a Pr ocesso r 4 3.
Figur e 4 2 Connec ting the P ow er Cable 1 1 . R einstall the shee t metal air duct . 1 2 . R eplace the cov er . 1 3 . V erify that the ne wl y installed pr ocessor w orks: • R un the info cpu command at the EFI shell pr ompt , or • Chec k the conf igur ation u sing the EFI S ys tem Co nfi gurati on menu .
3 . L ift up on the battery and push on the back o f it with a f lat-head scr e wdr iv er to r emo ve the battery fr om its holder . Figur e 43 Remo ving the Sy stem Batter y CA UTION: Onl y lift the bat tery high en ough to clear the ho lder . Ex ces siv e str ess on the battery holder r etaining c lip may damage the c lip .
5 . Y ou may need to r eset the s y stem time and date u sing the EFI time and date commands . Once y ou hav e set the time , turn the s y stem o ff , unplug the po w er cor d, and w ait for a minu te bef or e turning it bac k on . Exec ute the time and date commands again .
R eplac ing the P ow er Suppl y F an Unit T o r eplace a pow er supply f an unit , perfor m the fo llow ing steps: 1 . Ori ent the po we r supply f an unit b y aligning the appr opr iate i con on the fan unit t o the identi cal icon o n the chas sis wall .
3 . Chec k the fr ont panel diagnos tic LEDs f or indicati on of the r eplaced fan unit . • When the f an is func tioning no rmall y , the LED is off . • When the f an fails , the LED is on. 4. R eplace the cov er . R emo ving and R eplac ing the Displa y P anel The dis play panel pr ov ides the local interf ace to the HP Integr it y rx1 6 20.
R eplac ing the Displa y P anel T o r eplace the display pane l, perf orm the f ollow ing steps: 1 . P lace the displa y panel ov er the stand-off s on the chas sis. 2 . Install the f our flat-head phillips s cr e ws . 3 . Connec t the signal cable f r om the s ys tem boar d to the connecto r on the displa y panel.
R emo ving and R eplac ing the P CI I/O R iser As sembl y The s erver ma y contain u p to 2 PCI car ds. P CI cards ar e located on the PCI I/O r iser asse mbly . W ARN ING! Ensure that the s ystem is po wer ed-down and all po wer sources ha ve been disconnected from the server prior to r emov ing or replacing a PCI car d.
Figur e 4 7 Using Jac kscre w to Release PCI I/O R iser 4. L ift the PCI I/O r iser a ssembl y up and a wa y fr om the chas sis. P lace the remo ved P CI I/O r iser ass embly in an antis tatic con tainer .
Figur e 48 Remo ving the I/O Riser Assembl y 5 . R eplace the cov er . See “Remo ving and R eplac ing the Co v er” (page 30) . R eplac ing the P CI I/O R iser As sembl y 1 . R emov e the cov er . S ee “Remo ving and R eplac ing the Co ve r” (page 30) .
R emo ving and R eplac ing P CI Car ds The s erver ma y contain u p to 2 PCI car ds. P CI cards ar e located on the PCI I/O r iser asse mbly . W ARN ING! Ensure that the s ystem is po wer ed-down and all po wer sources ha ve been disconnected from the server prior to r emov ing or replacing a PCI car d.
Figur e 4 9 Using Jac kscre w to Release P CI I/O Riser 4. Gr asp the edges o f the PCI car d being r emov ed and gently r oc k the card r eleasing the connect or fr om the P CI I/O r iser connect or . P lace the remo ved P CI card in an an tistatic containe r .
7 . R eplace the cov er . See “Remo ving and R eplac ing the Co v er” (page 30) . Figur e 50 Remo ving the I/O Riser Assembly Figur e 5 1 Remo ving a P CI Slot Cov er R eplac ing a P CI Car d 1 . R emov e the cov er . S ee “Remo ving and R eplac ing the Co ve r” (page 30) .
3 . R elease the P CI I/O r iser b y lifting the relea se handle . This ac tion f ree s the PCI I/O r iser fr om the s ys tem boar d. 4. Gr asp the edges o f the PCI car d being r emov ed and gently r oc k the card r eleasing the connect or fr om the P CI I/O r iser connect or .
Figur e 5 3 Remo ving an Internal Har d Disk Driv e 3 . P lace the r emo ved dr i ve in an an tistatic co ntainer . 4. If a r eplacement disk dr i ve is n ot being inst alled, co ver the dr i ve slot w ith a slot filler panel . R eplac ing an Inte rnal Har d Disk Dr i v e One additional disk dr iv e ma y be added to y our HP Serve r in slot 1 .
1 . If installing an additi onal dr iv e, r emo v e the slot filler that is ins talled in slot 1 . If replac ing a disk dr iv e, the slot w ill be empty due to the disk dri ve being pr ev iou sly r emov ed . Figur e 54 Remo ving Disk Dri ve Slot F iller 2 .
Figur e 5 5 4. The disk dr iv e is no w corr ectly ins talled. R emo ving and R eplac ing the P o we r Suppl y The po wer su pply is located at the le ft fr ont of the s erver c hassis .
Figur e 5 6 P ower Suppl y Remo val/R eplacement 4. Car efull y lift the pow er supply cable f r ee fr om all r etaining c lips . 5 . At the r ear of the c hassis , r emov e the t w o sc re ws holding the po wer r eceptacle to the c hassis . 6 . L ift the pow er supply f orwar d and aw ay f r om the chas sis to r emo ve .
Figur e 5 7 P ow er Supply Cable 6 . R eplace the pow er supply f an unit into the c hassis . 7 . R eplace the cov er . R emo ving and R eplac ing a R emo vable Medi a Dr i v e The r emov able media dr iv e is located betw een the two sec tions o f the fr ont bez el.
R emo v ing a R emo v able Media Dr iv e T o r emov e a remo vable media dr iv e , perfor m the fo llow ing steps: 1 . T urn off the s ys tem and disconnec t all cables . 2 . R emov e the cov er . S ee “Remo ving and R eplac ing the Co ve r” (page 30) .
5 . P ull the dr iv e strai ght f orwar d appr o x imately 3/4” t o re lease the dr iv e fr om the tab on the cha ssis, the n lift up and out to r emo v e the dri ve fr om the chas sis. R eplac ing a R emo v able Media Dr iv e T o r eplace the re mov able D VD dr iv e, perf orm the f ollo w ing steps: 1 .
5 . Connec t the MP car d: a . Connec t the MP card cable t o its connector o n the sy stem boar d. b . Scr ew in the tw o mounting sc r ew s that connect the MP car d to the inter nal chas sis post . Figur e 60 Connecting the M anagement Process or Card 6 .
Figur e 6 1 Installing the External Mounting P osts 7 . R eplace the sy stem co ver(s) and r econnect the po w er and ext ernal cable s. Inf ormati on r equir ed to access , conf igur e and utili z e the management pr ocess or is pr ov ided in Chapt er 4, “Utiliti es, ” of the HP Integr ity r x1 6 20 Operati ons Guide .
Figur e 6 2 Location of Management Processor Battery 3 . L ift up on the battery and push on the back o f it with a f lat-head scr e wdr iv er to r emo ve the battery fr om its holder . CA UTION: Onl y lift the bat tery high en ough to clear the ho lder .
1 . R emov e the follo w ing componen ts fr om y our e xis ting base unit . R efe r to earlie r secti ons of this cha pter f or component r emov al and r eplacement ins tructi ons .
• Management Pr ocessor Blank (pr esen t when Manage ment Pr ocess or not inst alled) • P CI I/O Backplane Ass embly • CP U(s) and assoc iated P o w er P ods • CP U Airflo w guide (single CP U.
4 P ar ts Inf ormati on F ield R eplaceable P ar ts (FR U) L ist This c hapte r pro vide s parts infor mation f or the f ield r eplaceable units (FRU s) of the HP Integr it y rx1 6 20 Se r v er .
Figur e 65 Additional Components The it ems in this list appl y to the HP Int egrity rx1 6 20 Se r v er , e xcept w her e noted . 7 0 P arts Infor mation.
NO TE: P art number s are f ound b y using the part nomenc latur e fr om this list to selec t the corr ect part fr om the HP P artsurfer . If a part that is not listed in the FR U list needs to be r eplaced , the Base Unit R epair K it is req uir ed.
T abl e 1 F ield Replaceable P arts (FRU) List (continued) P ar t Number Ex c hange P ar t Number Replacement Description Item No. AB4 30 -04 00 1 Sheet Metal A ir Duct 1 3 AB4 30 -6 7 0 1 0 E CI Blan.
Inde x A anti-stati c wr ist stra p, 2 8 B base unit r eplacing , 66 C co ver r emov ing and replac ing , 30 D displa y panel r emov ing and replac ing , 48 F fan units r emov ing and replac ing , 46 .
An important point after buying a device HP (Hewlett-Packard) rx1620 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought HP (Hewlett-Packard) rx1620 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data HP (Hewlett-Packard) rx1620 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, HP (Hewlett-Packard) rx1620 you will learn all the available features of the product, as well as information on its operation. The information that you get HP (Hewlett-Packard) rx1620 will certainly help you make a decision on the purchase.
If you already are a holder of HP (Hewlett-Packard) rx1620, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime HP (Hewlett-Packard) rx1620.
However, one of the most important roles played by the user manual is to help in solving problems with HP (Hewlett-Packard) rx1620. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device HP (Hewlett-Packard) rx1620 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center