HP 1 : 1 0Gb Ether net BL -c S w itc h User G uid e Part Number 445876-001 May 2007 (First Edition).
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to chan ge without no tice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such produc ts and services.
Contents 3 Con te nt s Introduc tion .................................................................................................................................. 6 Additional references ...........................................................
Contents 4 Installing XFP transceivers .................................................................................................... ..................... 24 Supporting software and special cons iderations ......................................
Contents 5 Cannot connect to the switch console interface remo tely using SSH .............................................................. .. 57 Cannot connect to the sw itch SNMP interface ...........................................................
Introduction 6 Intr oducti on In this section Additional references .......................................................................................................... ...................... 6 Featur es .........................................
Introduction 7 • 9K jumbo frames that improve performance by in creasing application throughput and decreasing server processor utilization • Robust configuration and management from any sw itch port using the inc luded b rowser-based and scriptable command line user interfaces.
Introduction 8 Switch redundancy In a dual switch configuration, th e switch es offer several redundancy and failover features. Wit h these features, the networ k configuration is desi gned to allow for continued network access to each server blade in case of a component or link failure.
Introduction 9 • A text-based, human read/write configuration fi le provides viewing, printing, and editing capabilities. • A DNS client supports primary and secondary DNS servers. • Any port can be enabled or disabled as desired. • Any switch port can be used to perform switch management and PXE.
Introduction 10 ten Gigabit external Ethernet ports and sixteen internal Gigabit Ethernet ports providing connectivity to the blade servers within the enclosure. Redundant crosslinks In a dual switch configuration, the two switches are connected through a single te n gigabit crosslink.
Introduction 11 • High availability VRRP Layer 3 switching provides more powe r, flexibility, and security capabi lities to network administrators. Network traffic is managed much mo re efficiently and broadcast traffi c between servers remains within the enclosure.
Introduction 12 are members of a specific IP networ k. This is achieved by configurin g the address/mask of that specific network as a restricted mana gement network address/mask.
Introduction 13 RADIUS The switch supports the RADIUS method to authentica te and authorize remote administrators for managing the switch. This method is based on a client/server mo del. The RAS, the switch, is a client to the bac k-end database server.
Introduction 14 • The accounting attrib utes of pr otocol, start_time, stop_time, an d elapsed_time. For BBI users, accounting stop reco rds are only sent if the user presses the QUIT button. SSH and SCP SSH and SCP use secure tunnels to enc rypt and secu re messages between a rem o te administrator and the switch.
Introduction 15 through a procedure called auto-negotiation. Auto-neg otiation involves probing the capability of the network using low-level sign aling tech niques to select compatible Ethe rnet speeds . Auto-negotiation was originally developed to make the migration from traditional Ethernet to Fast Ethernet products easier.
Component identification 16 C ompone nt i dentif icati on In this section 1:10Gb Ethernet Blade Switch front panel ....................................................................................... ......... 16 1:10Gb Ethernet Blade Switch front panel CAUTION: Pressing the Reset button while the He alth LED is green resets the switch.
Component identification 17 Item Description 6 XFP transceiver cage port 21 • Green—Link LED (top) • Flashing green—Activity LED (bottom) 7 RJ-45 ports 22-25 Speed LED (right) • Off—10 Mb/.
Installing the switch 18 Inst alling the s w itc h In this section Preparing for installa tion ..................................................................................................... .................... 18 Planning the switch configuration .
Installing the switch 19 • Switch IP settings • VLAN settings • XFP settings • Port names and types • Port trunking settings • Interswitch X-Connect port settings • SNMP settings • Use.
Installing the switch 20 NOTE: It is recommended to change the default switch passwords after initial configuration and as regularly as required un der the network security policies. For more informa tion, see the HP 1:10Gb Ethernet BL-c Switch Command Referen ce Guide .
Installing the switch 21 Switch IP addresses are acquired by default using BOOTP, therefore, each switch has a unique IP address. Each switch is remotely accessed from a central deployment server an d an individu al switch configuration is downloade d to meet specific network requirements.
Installing the switch 22 A successful installation is indicated by a green Heal th LED. If the Health LED is amber or power is not applied to the switch, see the "Troubleshooting" se ction of the HP BladeSystem enclosure setup and installation guide for more information.
Installing the switch 23 NOTE: If the switch does not obtain the IP addr ess by means of the BOOTP service, access the switch locally and configure the IP address ma nually. After assigning the IP address to the switch, then access the switch remotely.
Installing the switch 24 Installing XFP transceivers CAUTION: To prevent damage to the fiber optic cable or the XFP transceiver, do not install or remove fiber-optic XFP transceive rs with cables attached. Disconnect all cables from the XFP transceiver before removing or installing an XFP transceiver.
Installing the switch 25 • Firmware Upgrade Smart Component (for Micros oft Windows only)—Provides quick and easy installation of the switch firm ware, firmware upgrade tool, and readme file. A SoftPaq is available for use with Linux operating systems.
Replacing a switch 26 R eplac ing a s w itc h In this section Replacing an ex isting switch ...........................................................
Replacing a switch 27 5. Close the ejector lever and wait for the switch boot up complet ely. 6. If the configuration file was saved to a TFTP server, download the configuration. For more information on downloading a configuration file, see the HP 1:10Gb Ethernet BL-c Switch Command Reference Gui de .
Regulatory compliance notices 28 R egulator y compliance noti ces In this section Class A eq uipment .............................................................................................................. ................... 28 Modifica tions .
Regulatory compliance notices 29 European Union regulatory notice This product complies with the foll owing EU Directives: • Low Voltage Directive 200 6/95/EC • EMC Directive 2004/ 108/EC Complian.
Regulatory compliance notices 30 Korean class A notice Laser compliance This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60 825-1.
Technical specifications 31 T ec hni cal spec if i cati ons In this section General spec ificat ions ......................................................................................................... ................... 31 Port names, VLANs, STP, trunking defa ult settings.
Technical specifications 32 Category Specification 100Base-TX Two Pair or Four Pair UT P Category 5 (100 m) EIA/TIA-568 100-ohm ST P (100 m) 1000Base-T Four Pair UTP Category 5e (100 m) EIA/TIA-568 100-ohm ST P (100 m) 10 Gb multimode fibe r cable 62.
Technical specifications 33 Port type Port number Port name STP Server 4 Downlink4 Disabled Server 5 Downlink5 Disabled Server 6 Downlink6 Disabled Server 7 Downlink7 Disabled Server 8 Downlink8 Disab.
Technical specifications 34 Setting Value Primary default gateway 0.0.0.0 Secondary default gateway 0.0.0.0 Primary DNS server address 0.0.0.0 Secondary DNS server address 0.
Technical specifications 35 Setting Value Port Trunking Load Sharing Algorithm The algorithm s elects the following as forwarding ports for forwarding traffic: 1 For forwarding IP Packets—modulus of.
Technical specifications 36 Setting Value Serial Port Parity Bit None Serial Port Stop Bit 1 Serial Port Flow Control None Default VLAN Default VLAN (VID=1) with all ports assigned including CPU, STG=1 NTP State Disabled NTP Server 0.
Technical specifications 37 Setting Value RADIUS Server Port 1645 RADIUS Server Retries 3 RADIUS Server Timeout 3 RADIUS Backdoor for Telnet Access Disabled Re-ARP Period in Minutes 10 MSTP Disabled M.
Technical specifications 38 Setting Value Aggregate IGMP Report Disabled IGMP Fastleave Disabled IGMP Fastleave VLANs None IGMP Filtering Disabled IGMP Filters None Static Multicast Router Port None U.
Technical specifications 39 Setting Value RMON Alarm Falling Event Index 0 RMON Alarm Owner Null IP Forwarding Disabled Configurable User Name - admpw admin Configurable User Name - opw Disabled Confi.
Technical specifications 40 Setting Value SNMPv3 - v1v2on ly subtree=1, inc luded subtree=1.3.6.1.6.3.15, excl uded subtree=1.3.6.1.6.3.16, excl uded subtree=1.
Technical specifications 41 Category Specification Best downlink external port packet forwarding rate ratio 16 : 5 Interswitch x- connects across enclosure backplane 1 X 10 Gb port MAC address learnin.
Performing a serial download 42 P erf or ming a ser ial do w nload In this section Introduc tion ................................................................................................................... ........................ 42 Serial upgrade of boot code firmware imag e proced ure .
Performing a serial download 43 4. Hold down the Shift key and press the D key repeat edly during the Memory Test, until this message appears: NOTE: To perform serial downloads at 57600 baud rate, press the Shif t-F keys. To perform serial downloads at 115200 baud rate, press the Shift-D keys.
Performing a serial download 44 8. Select <Transfer-Send File> from the menu and choose these options in the Send File window: The Send File window displays progress of the fil e transfer. The file transfer might take up to seven minutes. NOTE: Although slower, XModem also works if 1K MODEM is not used.
Performing a serial download 45 Serial upgrade of operating system firmware procedure To perform a serial upgrade of the switch operating system firmware image, usually named GbE2c-1- 10G_100.bin : 1. Using the null modem cable, connect the console port of the switch to the serial port of a PC that supports XModem/1K XMod em.
Performing a serial download 46 NOTE: To perform serial downloads at 57600 baud rate, press the Shif t-F keys. To perform serial downloads at 115200 baud rate, press the Shift-D keys. 5. After the message in Step 4 appears, reconfigur e the terminal emulation console using these parameters.
Performing a serial download 47 Depending on the selection, 1 or 2, the system updates image1 or imag e2 on the flash and a message with a progress indicator displays as show n below. If selecting n, the system aborts th e update procedure and prompts to reset the baud rate and power cycle the switch.
SNMP MIBs support 48 S NMP MI B s suppor t In this section MIB over view................................................................................................................... ...................... 48 SNMP Manage r software ..............
SNMP MIBs support 49 Supported MIBs The SNMP agent for the switch supports t hese MIBs: • dot1x.mib • GbE2c-1-10G-L2L3.mib • GbE2c-1-10G-L2L3_cpqhost.mib • GbE2c-1-10G-L2L3_cpqrack.mib • GbE2c-1-10G-L2L3 _cpqsinfo.mib • rfc1213.mib • rfc1215.
SNMP MIBs support 50 o risingAlarm o fallingAlarm • GbE2c-1-10G-L2L3.mib traps o bntSwDefGwUp o bntSwDefGwDown o bntSwDefGwInService o bntSwDefGwNotInService o bntSwLoginFailure o bntSwTempExceedThr.
Electrostatic discharge 51 Elec tr o stati c disc har ge In this section Preventing electros tatic discharge ............................................................................................. ................ 51 Grounding methods to preven t electrostati c discharge .
RJ-45 pin specification 52 RJ- 4 5 p in spec if i catio n In this section Standard RJ-45 rece ptacle/connec tor ............................................................................................ ........... 52 RJ-45 to DB-9 serial adapter with flow control pin assignment .
RJ-45 pin specification 53 RJ-45 to DB-9 serial adapter with flow control pin assignment RJ-45 signals RJ-45 pins DB-9 pins DB-9 signals Request to send (RTS) 1 8 Clear to send (CTS) Data set ready (D.
Troubleshooting 54 T r oubleshooting In this section Forgotten administrator user name and passw ord that was configur ed on the switch ...................................... 54 Health LED on the switch is not on ......................................
Troubleshooting 55 • The server blade enclosure is not powered up. Be su re that the server blade enclosu re is powered up and all the power connections are intact. • There is a faulty LED. Check the console to see i f the switch is booted. • The switch fuse is blown.
Troubleshooting 56 Error message that the switch failed to complete the system self-testing appears on the serial console screen Action: The system diagnostic tests failed. Note t he reason fo r the failure from the serial console scre en message and call a service representative.
Troubleshooting 57 • The setting allowing access to the switch usin g the Telnet interface is disabled. From the serial console interface, be sure t hat the Telnet interface is enabled. • The management network address/mask (if used) does not contain the IP address of the management station.
Troubleshooting 58 The port activity LEDs continuously indicate activity after connecting more than one port to another switch or destination device Action: Because there are multiple l inks across this device and the destination device, they form loops, which cause broadcast storms.
Troubleshooting 59 The switch does not let the user enable two adjacent ports into two different VLANs while assigning the ports to VLANs Action: The ports are two adjacent ports that are bundled in a Port Trunk. Two ports that are assigned to a Port Trunk cannot be assigned to two differen t VLANs.
Troubleshooting 60 o Be sure that a valid configuratio n file exists on the TFTP server to download to the switch. o On the switch, check the file name con figured to download or upload.
Acronyms and abbreviations 61 A c r on y ms and abbr e v iati ons AAA authentication, authorization, and acc ounting BBI browser-based interface BOOTP Bootstrap Protocol CLI Command Line Interface CPU.
Acronyms and abbreviations 62 IEEE Institute of Electrical and Electroni cs Engineers IGMP Internet Group Management Protocol IP Internet Protocol iSCLI industry standard command line interface LACP L.
Acronyms and abbreviations 63 NTP network time protocol NVRAM non-volatile memory OID object identifier OS operating system OSI Open Systems Interconnection OSPF open shortest path first POST Power-On.
Acronyms and abbreviations 64 SCP Secure Copy SFP small form-factor pluggable SNMP Simple Network Management Protocol SSH Secure Shell STP Spanning Tree Protocol TACACS+ Terminal A ccess Controller Ac.
Index 65 A accessing the switch serial console inter face, troubleshooting 55 additional references 6 architecture 9 Auto-MDI/MDIX 14 auto-negotiation of duplex mode and speed 14 B BOOTP server, troub.
Index 66 planning switch configuration 18 port mapping 9 port mirroring 12 port trunking 12 R redundancy 8, 10, 15 redundant crosslinks 10 redundant images in firmware 15 redundant paths to server bay.
An important point after buying a device HP (Hewlett-Packard) Ethernet BL-c Switch (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought HP (Hewlett-Packard) Ethernet BL-c Switch yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data HP (Hewlett-Packard) Ethernet BL-c Switch - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, HP (Hewlett-Packard) Ethernet BL-c Switch you will learn all the available features of the product, as well as information on its operation. The information that you get HP (Hewlett-Packard) Ethernet BL-c Switch will certainly help you make a decision on the purchase.
If you already are a holder of HP (Hewlett-Packard) Ethernet BL-c Switch, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime HP (Hewlett-Packard) Ethernet BL-c Switch.
However, one of the most important roles played by the user manual is to help in solving problems with HP (Hewlett-Packard) Ethernet BL-c Switch. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device HP (Hewlett-Packard) Ethernet BL-c Switch along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center