X-XX UL INST ALLA TION INSTRUCTIONS ®U.S. Registered Trademark Copyright © 1998 Honeywell Inc. • All Rights Reserved 69-0668-1 VR8300A Continuous Pilot Combination Gas Control APPLICA TION These continuous pilot gas controls are used in gas-fired appliances with capacities up to 200 cfh at 1 in.
69-0668—1 2 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTROL INST ALLA TION When Installing this Product… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazard- ous condition.
69-0668—1 3 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTR OL COLOR CODE FOR LP GAS NATRUAL GAS CAP SCREW BLACK SILVER PRESSURE REGULATOR ADJUSTING SCREW WHITE WHITE TAPERED SPRING RED STAINLESS STEEL PRESSURE REGULATOR HOUSING M16015 Fig. 1. Install conversion kit in regulated gas control.
69-0668—1 4 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTROL Install Gas Control To install: 1. Mount the gas control 0 to 90 degrees, in any direction, from the upright position of the gas control knob, including vertically. 2. Mount the gas control so the gas flow is in the direction of the arrow on the bottom of the gas control.
69-0668—1 5 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTR OL GAS CONTROL TIGHTEN NUT ONE TURN BEYOND FINGER TIGHT. FITTING BREAKS OFF AND CLINCHES TUBING AS NUT IS TIGHTENED. TO PILOT BURNER M3076A 2. Square off and remove the burrs from the end of the tubing.
69-0668—1 6 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTROL Table 5. Maximum Length of Supplementary Limit Leadwires in in. (m) When Using Q340A Thermocouple. Maximum Leadwire Length x 2 (Wires) Thermocouple Length AWG No. 14 AWG No. 16 AWG No. 18 in.
69-0668—1 7 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTR OL Light Pilot Burner Flame 1. Turn the gas control knob clockwise to OFF. Wait five minutes to dissipate any unburned gas. Sniff around the appliance near the floor. Do not relight the pilot flame if you smell gas.
69-0668—1 8 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTROL 4. If the desired outlet gas pressure or gas flow rate cannot be achieved by adjusting the gas control, check the gas control inlet pressure using a manometer at the inlet pressure tap. If the inlet pressure is in the normal range (refer to Table 7 or 8), replace the gas control.
69-0668—1 9 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTR OL SER VICE W ARNING Fire or Explosion Hazard. Can cause property damage, severe injury or death Do not disassemble the gas control; it contains no replaceable components. Attempted disassembly or repair can damage the gas control.
69-0668—1 10 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTROL IMPORTANT Follow the operating instructions provided by the manufacturer of your heating appliance.
69-0668—1 11 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTR OL.
69-0668—1 12 VR8300A CONTINUOUS PILO T COMBINA TION GAS CONTROL Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 3N7 69-0668—1 J .S. Re v . 6-98 Home and Building Control Honeywell Inc. Honeywell Plaza P.
An important point after buying a device Honeywell VR8300A (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Honeywell VR8300A yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Honeywell VR8300A - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Honeywell VR8300A you will learn all the available features of the product, as well as information on its operation. The information that you get Honeywell VR8300A will certainly help you make a decision on the purchase.
If you already are a holder of Honeywell VR8300A, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Honeywell VR8300A.
However, one of the most important roles played by the user manual is to help in solving problems with Honeywell VR8300A. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Honeywell VR8300A along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center