Honeywell UD

4 pages·163 KB·Home Security System·PDF·ENDEFRITNLJA
Honeywell UD
Table of Contents 15 sections MIP-2/UD · IP Communicator for Burglar Alarm Panels · General · Easy to Program · … ShowHide
Page 1 of the Honeywell UD user manual — Installation Requirements
Page 1 · click to enlarge
Page 1

MIP-2/UD

IP Communicator for Burglar Alarm Panels

Honeywell UD — IP Communicator for Burglar Alarm Panels diagram (page 1)
Fig. 1 · IP Communicator for Burglar Alarm Panels

General

The MIP-2/UD is a simple communications device that allows the transmission of alarms generated by a conventional control panel through any kind of IP network (ADSL, cable, Inter- net…), at the same time that it keeps the standard telephone line as a back-up mechanism.

Designed to work with most of the already installed control panels, the MIP-2/UD allows for a faster and more economic alarm transmission, improving response times, decreasing costs and offering value added features such as the super- vised line functionality that allows the central station to detect if any of the alarm panels go off-line. At the central station side, Teldat has designed an IP receiver, the VisorALARM PLUS, that will integrate seamlessly into conventional central station architectures

Easy to Program

There are three ways to configure the IP Communicator:

1. Console terminal using the HyperTerminal™ software program found on all Microsoft® operating systems. 2. Local or remote Telnet session via Ethernet connection. 3. Windows-based configuration software (shipped with IP Communicator). The IP Communicator can be pre-programmed. The program- mer enters all central-station information and an auto-registra- tion password. This is saved to the unit’s flash memory. When the IP Communicator is installed at the site and connected to the Internet/Intranet, it registers itself with the central station receiver. This eliminates the need for a PC at the remote site for programming. The IP receiver at the monitoring station will automatically configure other parameters during registration.

  • Features
  • Allows any Contact-ID Burglar alarm panel to transmit alarms over IP networks.
  • Saves the cost of an 800 number to receive alarms. Transmission is done through a flat rate Internet connection that is shared with other devices.
  • Eliminates the cost of two dedicated phone lines. Only the customer’s shared IP equipment is required.
  • Can use newer low-cost, non-analog, digital telephone services such as cable or fiber optics.
  • Increases connection supervision to the central station from the once-a-day test signal to once every 30 - 90 seconds.
  • Requires no change to the existing panel configuration. The IP Communicator connects directly to the primary and secondary analog panel telephone ports.
  • Fast alarm transmission (less than 1 second transmission time) for better response times to burglar alarms.
  • Works over any type of customer-provided Ethernet 10/100 Base network connection (LAN or WAN), DSL modem or cable modem.
  • Data transmits over standard contact-ID protocol but is secured with the industry’s highest level of encryption (AES 512 bit).
  • Supports both dynamic (DHCP) or Public and Private Static IP addressing.
  • Supports dual-destination IP receiver address for high redundancy configurations: all signals are sent to a secondary address should the primary become unavailable.
  • MIP-2/UD can be installed inside the alarm panel or inside its own wall mount enclosure.
  • Upload/Download capabilities: Allows central station operators to manage the remote alarm panels over IP using the VisorALARM PLUS receiver to manage all the connections, protocols and additional features. You will be able to program, upgrade, download or perform any operation. Teldat actually supports panels like Vista, Paradox, and Networks.
  • Supports an optional third maintenance receiver installed at the end user’s facility that permits local alarm monitoring. Alarms are received simultaneously at both the central station and the customer’s facility. A filter can be applied to annunciate specific alarm types such as trouble-only events.

F OR MOST INSTALLATIONS , THE ONLY REQUIRED PARAMETERS

  • ARE :
  • Selection of either DHCP or Static IP.
  • Destination primary and secondary receiver IP addresses.
  • Account identification number (CID).
  • Port number.
  • Installation password. All of these parameters are assigned by the central station.

Installation Requirements

  • Burglar panel compatible with Contact-ID format.
  • At least 250mA of electrical power available on the power supply to use for the MIP UD unit (500mA recommended).
  • Ethernet network connector (10/100 Mbps).
  • DHCP server present on the local network or an available IP address to be used with the MIP UD.
  • UDP port to use with for the MIP UD communication with the monitoring station (default port: 80).
  • Destination IP addresses of the VisorALARM receivers where the MIP UD will be sending alarms and other events.
  • Panel account ID number (CID).
  • Installer password (provided by the monitoring station managing the VisorALARM IP receiver).
Page 2 of the Honeywell UD user manual — TELNET, ETHERNET BLUEBOK INPUTS AND OUTPUTS:
Page 2 · click to enlarge
Page 2

System Architecture/Operating Theory

  • The MIP-2/UD is connected to an Internet router.
  • The telephone line, instead of going directly to the panel, is now connected to the MIP-2/UD and from the MIP UD it is then connected to the panel.
  • The MIP-2/UD monitors the status of the Internet connection with the receiver and decides which network to use to transmit the alarms received from the panel.
  • At the central station side, a conventional receiver will still be used to receive alarms transmitted through the telephone line. If the Internet connection is available, the alarms will be sent to a VisorALARM receiver at the monitoring station.
  • The MIP-2/UD keeps constant communication with the panel to implement a real time line supervision functionality.
Honeywell UD — System Architecture/Operating Theory diagram (page 2)
Fig. 2 · System Architecture/Operating Theory

Specifications

CONSOLE:

Asynchronous: 9600 bps, 8 bits, without parity, 1 stop bit.

P OWER Nominal voltage10 VDC to 24 VDC

Password protected.

Max current:

Telephone: Connection through TO-AP using a telephone key pad.

IdleAlarmTransientUD A 12Vdc160mA180mA400mA330mA A 24Vdc90mA104mA200mA160mA

TELNET: Password protected.

Dimensions and Weight

5.5L x 3.62W x 1.42H inches

LAN PORT Connector: RJ45 female.

Weight150 gr / 3 ounces

Speed: 10 Mbps.

Temperature and Humidity Ranges

Protocols: UDP, IP, SRP, DHCP, AES.

This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 27°C/60 - 80°F.

TELNET, ETHERNET BLUEBOK INPUTS AND OUTPUTS:

Output 1: 500 mA. Dry Contact N.O. or N.C. 2A Max.

Output 2: 500 mA. WatchDog.

Inputs: 2.

Page 2 of 4 — DH-60768:A • 3/11/2013 www.honeywell.com

Page 3 of the Honeywell UD user manual — Agency Listings and Approvals
Page 3 · click to enlarge
Page 3

Agency Listings and Approvals

Ordering Information

In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be process. Consult factory for latest listing status.

MIP-2: IP Communicator. Includes configuration software and manual.

MIP-2UD: IP Communicator with upload/download capability (2UD modem daughter board). Includes configuration software and manual.

  • BURGLAR
  • UL1023: Household Burglar Alarm System-Units.
  • UL1076: Proprietary Burglar Alarm Units and Systems.
  • UL1610: Central Station Burglar Alarm Units.
  • ULC C1023-1974: Household Burglar Alarm System-Units.
  • ULC/ORD=C1076-M1986: Proprietary Burglar Alarm Units and Systems.
  • CAN/ULC S304-M88: Central and Monitoring Station Burglar Alarm Units.

IPENC: External mounting enclosure consisting of mounting bracket IPBRKT, and screws. Enclosure must be "close-nip- ple" to a panel. (Red)

IPSPLT: Y adapter option to allow connection of both panel dialer outputs to one cable input to MIP-2/UD.

ALMSC-119: Serial programming cable.

HP300ULX: Honeywell Power Products UL 1481-listed auxil- iary power supply. Enclosure must be "close-nipple" to a panel via conduit. Requires IPBRKT purchased separately.

IPBRKT: Mounting bracket.

www.honeywell.com DH-60768:A • 3/11/2013 — Page 3 of 4

Page 4 of the Honeywell UD user manual — Automation and Control Solutions
Page 4 · click to enlarge
Page 4

This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice.

©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.

Automation and Control Solutions

12 Clintonville Road 1(877) HPP-POWR

Northford, CT 06472-1610 hpp.techserv@honeywell.com

www.honeywellpower.com

DH-60768:A April 2013 Made in the U.S.A. ® U.S. Registered Trademark © 2013 Honeywell International Inc. Page 4 of 4

Honeywell

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Honeywell UD

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Honeywell UD

Be the first to ask — other owners or our team will answer.

Original document

Honeywell UD manual PDF

4 pages·163 KB·Home Security System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…