Models:
C645B Pressure Switches—break a circuit when pressure
C645A,C,D Pressure Switches—break a circuit when
rises to scale setting. Refer to Table 1. C645E—breaks circuit when pressure falls to scale setting
pressure falls to scale setting minus the differential. Refer to Table 1.
minus the differential. Refer to Table 1.
Table 1. Pressure switch model selection.

Alternate Electrical Ratings when used with Honeywell Flame Safeguard Programmers (all C645 models):
ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the TRADELINE® catalog or price sheets for complete ordering number, or specify—
If you have additional questions, need further information, or would like to comment on our products or services please write or phone:
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International sales and service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
60-2159—8 2

Switching: Spdt Micro Switch snap-acting switch (Fig. 3).
Canadian Standards Association listed: C645A-E, File no.
LR1620-369, Guide no. 140-A-2; for use subject to same ambient temperature restrictions as Underwriters Laboratories Inc. Factory Mutual Approved. Industrial Risk Insurers: C645A-D models with window in
Minimum Ambient Temperature: -20°F (- 29°C).
Maximum Ambient Temperature: 125°F (52°C).
cover approvable for applications on burners over 5 million Btuh (5 thousand cfh) input.
Connections:
Optional Specifications:
1/4-18 NPT female tapping for main or high pressure connection. 1/8-27 NPT female tapping for venting or low-pressure connection.
Approvals:
no. MP2168, Guide no. MFHX; for use in ambient temperatures normally prevailing in occupiable spaces, which usually are not higher than 77°F (25°C) but can occasionally be as high as 104°F (40°C) for brief periods.
Accessories:
3-1/2 (88.9)
3/16 (2) (4.8)
4 (101.6)
3-1/2 (88.9)
4-3/4 (120.6)
1/8-27 NPT
3/8 (9.5)
5/8 (15.9)
3/8 (9.5) 1-1/8 (28.6)
2-1/2 (63.5) 1-5/16 (33.3)
Fig. 1. Dimensions of C645A,B,D, and E in in. (mm).
2-7/8 (73) · 60-2159—8 3

3-7/8 (98.4)

Fig. 2. Dimensions of C645C in in. (mm).
When Installing this Product . . .
Mounting The C645 has a hexagonal fitting with a 1/4 in. NPT tapping, which is the high pressure connection in differential applications. The bleed fitting is 1/8 in. NPT female tapped. In differential pressure control applications using air, connect the lower pressure to the bleed fitting (Fig. 3 and 4). In applications using combustible gases, vent the bleed tapping according to applicable standard code or jurisdictional authority.
Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the
product to make sure the product is suitable for your application. Installer must be a trained, experienced service
technician. After installation is complete, check out product
operation as provided in these instructions.
The C645A,B,D can be mounted in any position but are more accurate when mounted horizontally. The C645C is mounted with the diaphragm vertical and the bleed fitting at the bottom.
3-5/8 (92) · 5 (127) · 60-2159—8 4

The C645E1002 Distillate Fuel Oil Pressure Switch is the same as the C645A1006 Gas Pressure Switch except that it does not have a 0.015 in. (0.38 mm) diameter (nominal) orifice in its 1/4 in. NPT main (high pressure) connection. (This orifice is required in a C645A Gas Pressure Switch to restrict gas leakage, but it is too small for oil applications.) The C645E1002 has a 0.125 in. (3.18 mm) diameter (nominal) opening in its 1/4 in. NPT main connection into its pressure chamber.
OPENING FOR 1/2 INCH CONDUIT MANUAL RESET LEVER ON LOCKOUT MODELS ONLY

Wiring Disconnect power supply before connecting wiring to prevent electrical shock and equipment damage.
SET POINT ADJUSTMENT SCREW
SCALE PLATE
BLEED FITTING
All wiring must agree with applicable codes, ordinances, and regulations. An opening is provided to accommodate rigid conduit or armored cable for line voltage operation (Fig. 3 and 4). Do not overload the switch contacts (see Switch Ratings in Specifications section). The switching schematic is shown in Fig. 5.
Fig. 4. C645C with cover removed.

BLEED FITTING
COVER SCREW OPENING FOR 1/2 INCH CONDUIT
W
B
MICRO SWITCH
R
C645A,C,D BREAKS R-W, MAKE R-B ON PRESSURE FALL. MANUAL RESET MODELS LOCK OUT.
C645B BREAKS R-B, MAKES R-W ON PRESSURE RISE AND LOCKS OUT. M7565
Fig. 3. C645A,B,D with cover removed.
Fig. 5. Schematic showing switch in zero
pressure condition.
60-2159—8 5


Specifications Scaleplate Stop: Limits maximum setting, factory-set at 5-1/4 in. of water (1.31 kPa).

Scale Range: 3 to 21 in. of water (0.75 to 5.23 kPa).
Adjusting Wrench: Part no. 23466 included with the C645B1047.
Remove cover. Loosen scaleplate stop locking screw about 1/2 turn
counterclockwise with the 23466 Adjusting Wrench. Move scaleplate stop until bottom edge is aligned with
desired maximum setting. Tighten scaleplate stop locking screw clockwise . Replace cover.
60-2159—8 6

The C645B spring-loaded diaphragm actuates the Micro Switch snap-acting switch which breaks a control circuit, locks out, and turns on an alarm (if so wired) when the pressure rises to the scale setting. When pressure falls to the scale setting minus the differential, the switch lockout can be manually reset, turning off the alarm

Set cutoff pressure. Open main supply line. Depress reset lever on lockout
models until switch makes R-W. Set controller and limit switch to call for heat. For C645A—close main shutoff valve. Valve should
close when pressure reaches cutoff point. For C645B—wait a few minutes for the pressure to rise; then lower the scale setting until the switch makes R-W and locks out.
SET POINT INDICATOR
Fig. 6. Adjusting C645B1047 scaleplate stop.
Manual Resetting The C645A,C manual reset models lock out at scale setting minus the differential and require manual resetting after the pressure rises to scale setting to resume normal operation.
For C645A—reconnect the control valve, open the
shutoff valve, press the reset lever (if necessary), and return the pressure switch to its original setting. For C645B—raise setting to normal. Depress reset lever. Allow system to operate through at least one complete
The C645B locks out at scale setting and requires manual resetting after the pressure falls to scale setting minus the differential to resume normal operation. To reset, push the reset button as far as it will go; then release.
cycle to make certain all components are functioning properly.
C645C,D—Air Switch Only
Lockout models cannot be made to recycle automatically by permanently holding in the reset lever.
Set cutoff pressure. Turn on fan. If using a manual rest C645, depress and hold lever
until switch makes R-W. Block fan inlet or filter area. Switch should break R-W,
make R-B when pressure drops to cutoff point. Manual reset models lock out. Remove obstruction. Depress reset lever and allow
Operation The C645A,C,D,E spring-loaded diaphragm actuates the Micro Switch snap-acting switch to break a control circuit when pressure falls to scale setting minus differential. The switch can be wired to turn on an alarm at the same time. When the pressure rises to the scale setting, the control circuit requires manual resetting to reset and turn off alarm. Optional C645A model will recycle automatically when the control circuit returns to scale setting.
system to operate through at least one complete cycle to make certain all components are functioning properly.
The C645E1002 is the same as the C645A1006 Gas
Pressure Switch except the C645E1002 has a 0.125 in. NPT main connection in its pressure chamber. See Checkout for C645A.
60-2159—8 7

Home and Building Control Honeywell Inc. 1985 Douglas Drive North Golden Valley, Minnesota 55422
Home and Building Control Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9
60-2159—8 F.P. Rev. 5-95 www.honeywell.com/bbc
60-2159—8 8