Turn off the computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected.



Connecting the Scanner

Scan Recall Defaults to reset all standard product default settings.
³ 9 8 Recall Defaults

USB
³ 4 1 6 4 0 0 USB Keyboard
Load Integrated Full Speed USB IBM/OEM
Emulation · Defaults · USB Serial Emulation

³ 4 1 5 5 5 4 RS232
Keyboard Wedge
³ 5 1 5 5 1 4 3 Keyboard Wedge Emulation
Scan a bar code to select one of the following keyboard country templates. Refer to your Configuration Guide for additional keyboard country settings.
³ 4 1 6 2 6 0 United States

³ 4 1 6 2 3 0 Germany/Austria
³ 4 1 6 2 2 0 France
Belgium · United Kingdom

Use ALT Mode when bar codes or formatting rules include Extended ASCII data that might not have a direct keyboard equivalent. If your bar code contains special characters from the extended ASCII chart, scan the Enable 3-digit ALT Mode or Enable 4-digit ALT Mode codes below. The key sequence based on the ASCII value would be sent to the host (e.g., if an asterisk (*) is contained in the bar code, the host receives ALT + 0 + 4 + 2 (3-digit). If an “Ü” is contained in the bar code, the host receives ALT + 0 + 2 + 2 + 0 (4-digit). You may also se ALT Mode when no "Keyboard Country" bar code that matches your keyboard exists.
Italy · Spain

appropriate Keyboard Country code.
³ 1 1 6 2 1 7 Enable 3-digit ALT Mode
Disable 3-digit ALT Mode
Enable 4-digit ALT Mode
Disable 4-digit ALT Mode

³ 1 1 5 8 1 6 RTS/CTS Handshaking On
³ 1 1 5 9 1 4 XON/XOFF On
³ 1 1 5 9 1 3 ACK/NAK On
³ 1 1 6 0 1 3 8 Data Bits

³ 1 1 6 0 1 4 1 Stop Bit
³ 3 1 6 0 4 5 No Parity
Scan the following bar codes to have the scanner to enter/exit from various power save modes.
³ 3 1 9 4 1 0 Blink

Laser Off Power Save
Laser and Motor Off
Power Save Mode Always
³ 8 1 8 6 0 0 Power Save Mode Never
Power Save

Scan the Enable D/E Disable bar code below to disable scanning after the scanner receives an ASCII “D” from the host. Scanning is enabled when the scanner receives and ASCII “E”.
Enable D/E Disable · Disable D/E Disable

Scan the Activate DC2 Character bar code below initiate scanning with the receipt of a DC2 character (^R, 124).
³ 1 1 8 1 1 0 Activate DC2 Character
³ 1 1 8 1 0 0 Do Not Activate
Scanning the Transmit Serial Number code transmits the scanner’s serial number.
³ 9 6 9 Transmit Serial Number
DC2 Character

Scan the Laser LED Off/Scan LED Off bar code to turn off the laser/scan LED while scanning bar codes. The LEDs continue to illuminate for all other functions.
Laser LED Off · Scan LED Off

Scan one of the following bar codes to program your scanner to add or remove a start of text character, or AIM, NCR, or Nixdorf identification characters before each bar code.
³ 1 0 7 9 1 5 AIM ID Prefix On
STX Prefix On · STX Prefix Off

³ 1 0 7 9 0 5 AIM ID Prefix Off
³ 1 0 7 9 1 1 NCR Prefix On
³ 1 0 7 9 1 7 Nixdorf Prefix On
NCR Prefix Off

³ 1 0 7 9 0 7 Nixdorf Prefix Off
Scan one of the following bar codes to program your scanner to add or remove a carriage return, line feed, tab, or end of text after each bar code.
CR Suffix On · CR Suffix Off

³ 1 1 6 6 1 2 LF Suffix On
³ 1 1 6 6 0 2 LF Suffix Off
³ 1 1 6 6 1 0 Tab Suffix On
³ 1 1 6 6 0 0 Tab Suffix Off

³ 1 1 6 6 1 4 ETX Suffix On
One or two prefix or suffix characters can be added and assigned for data transmission. Use one of the codes below with a 3 code byte sequence that represents the desired character (see ASCII Conversion Chart, end of document) for your prefix or suffix. (To add additional prefix/suffix characters, refer to your Single-Line Configuration Guide.)
Scan the Enter/Exit Programming bar code to begin. Then scan the 3 digit decimal equivalent of the ASCII character into the appropriate character location with the code byte bar codes (see Code Bytes, end of document). To save, scan the Enter/ Exit Programming bar code again.
ETX Suffix Off

³ 9 Enter/Exit Programming
³ 9 0 3 5 0 0 Configurable Prefix #1

³ 9 0 3 6 0 0 Configurable Prefix #2
³ 9 0 4 5 0 0 Configurable Suffix #1
³ 9 0 4 6 0 0 Configurable Suffix #2
Scan one of the bar codes below to program your scanner for 2 or 5 digit bar code supplements.

2 Digit Supplements On
³ 1 0 1 2 0 7 2 Digit Supplements Off
³ 1 0 1 2 1 6 5 Digit Supplements On
³ 1 0 1 2 0 6 5 Digit Supplements Off

977 (2 Digit) Supplement Required: Turn on this feature when a 2 digit supplement is required for EAN-13 codes that begin with 977.
³ 1 0 1 3 1 4 977 Supplements On
³ 1 0 1 3 0 4 977 Supplements Off

Scan Convert UPC-A to EAN-13 and a leading zero is transmitted before a UPC-A bar code to convert it to EAN-13.
³ 1 0 7 5 1 4 Convert UPC-A to
³ 1 0 7 5 0 4 Don’t Convert UPC-A to

Scan Transmit Lead Zero on UPC-E to transmit a zero before each UPC-E bar code.
³ 1 0 7 5 1 3 Transmit Lead Zero on
³ 1 0 7 5 0 3 Don’t Transmit Lead
Zero on UPC-E

Scan Transmit UPC-A Number System to transmit the UPC-A leading digit with the bar code data. To transmit just the data, without the leading digit, scan Don’t Transmit UPC-A Number System.
Transmit UPC-A Number System
³ 1 0 7 5 0 1 Don’t Transmit UPC-A
Number System

Expand UPC-E to 12 Digits expands the UPC-E code to the 12 digit, UPC-A format.
³ 1 0 7 5 1 5 Expand UPC-E to 12
³ 1 0 7 5 0 5 Don’t Expand UPC-E to
Digits · 12 Digits

When Code 39 Full ASCII On is scanned, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and / C will be decoded as the ASCII character #.
³ 1 0 0 2 1 7 Code 39 Full ASCII On
³ 1 0 0 2 0 7 Code 39 Full ASCII Off
The following selections allow you to specify whether the check digit should be transmitted at the end of the scanned UPC-A or UPC-E data.

*Transmit UPC-A Check Digits
³ 1 0 7 5 0 7 Don’t Transmit UPC-A
³ 1 0 7 5 0 6 *Don’t Transmit UPC-E Check Digits
Check Digits · Transmit UPC-E Check · Digits

Due to the large spaces commonly found in GS1 DataBar symbologies, it is recommended that you enable GS1 Double Border Required. Scan the other codes below to enable/disable GS1 Databar 14 and GS1 Limited.
Enable GS1 Databar 14
³ 1 0 0 4 0 3 Disable GS1 Databar 14
GS1 Double Border · Required

³ 1 0 0 4 1 4 Enable GS1 Limited
³ 1 0 0 4 0 4 Disable GS1 Limited
Scan one of the following codes, then scan the Recall Defaults code, to program the scanner for one of the following configurations.

³ 9 8 Recall Defaults

Minimum Symbol Length specifies the minimum number of characters allowable for non-UPC/EAN bar codes. Scan the Enter/Exit Programming bar code to begin. Scan Minimum Symbol Length, then scan the minimum number of characters allowed using code byte bar codes, below. To save, scan the Enter/Exit Programming bar code again.
³ 9 Enter/Exit Programming
³ 9 0 1 8 0 0 Minimum Symbol Length






Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char
0 00 NUL 26 1A SUB 52 34 4 78 4E N 104 68 h
1 01 SOH 27 1B ESC 53 35 5 79 4F O 105 69 i
2 02 STX 28 1C FS 54 36 6 80 50 P 106 6A j
3 03 ETX 29 1D GS 55 37 7 81 51 Q 107 6B k
4 04 EOT 30 1E RS 56 38 8 82 52 R 108 6C l
5 05 ENQ 31 1F US 57 39 9 83 53 S 109 6D m
6 06 ACK 32 20 58 3A : 84 54 T 110 6E n
7 07 BEL 33 21 ! 59 3B ; 85 55 U 111 6F o
8 08 BS 34 22 “ 60 3C < 86 56 V 112 70 p
9 09 HT 35 23 # 61 3D = 87 57 W 113 71 q
10 0A LF 36 24 $ 62 3E > 88 58 X 114 72 r
11 0B VT 37 25 % 63 3F ? 89 59 Y 115 73 s
12 0C FF 38 26 & 64 40 @ 90 5A Z 116 74 t
13 0D CR 39 27 ‘ 65 41 A 91 5B [ 117 75 u
14 0E SO 40 28 ( 66 42 B 92 5C \ 118 76 v
15 0F SI 41 29 ) 67 43 C 93 5D ] 119 77 w
16 10 DLE 42 2A * 68 44 D 94 5E ^ 120 78 x
17 11 DC1 43 2B + 69 45 E 95 5F _ 121 79 y
18 12 DC2 44 2C , 70 46 F 96 60 ‘ 122 7A z
19 13 DC3 45 2D - 71 47 G 97 61 a 123 7B {
20 14 DC4 46 2E . 72 48 H 98 62 b 124 7C |
21 15 NAK 47 2F / 73 49 l 99 63 c 125 7D }
22 16 SYN 48 30 0 74 4A J 100 64 d 126 7E ~
23 17 ETB 49 31 1 75 4B K 101 65 e 127 7F
24 18 CAN 50 32 2 76 4C L 102 66 f
25 19 EM 51 33 3 77 4D M 103 67 g

For patent information, please refer to www.honeywellaidc.com/patents Technical Assistance
Contact information for technical support, product service, and repair can be found at www.honeywellaidc.com Limited Warranty
Refer to www.honeywellaidc.com/warranty_information for your product’s warranty information. User Documentation
For localized versions of this document, and to download the Configuration Guide or the Installation and User’s Guide, go to www.honeywellaidc.com
Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.

This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII.
© 2012 Honeywell International Inc. All rights reserved.





Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707
Omni-QS Rev A · 05/12
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.