GB Instruction Manual BPW-1000-EU Blood Pr essure Monitor IB-BPW1000-0912-01_Layout 1 09/01/2013 13:01 Page 1.
2 GB HO ME DI CS BLO OD PR ES SU RE MO NI T O R Before use Before the blood pressur e monitor is taken into use a number of basic steps should be observed. Please read this manual thoroughly befor e the blood pressure monitor is used for the first time and keep the manual for futur e use.
3 GB connection between values (mmHg) is expressed as e.g . 130 over 85 which means that the systolic pressure is 130 and the diast olic pressure is 85. Why is it important to keep an e ye on your blood pressure? Many of today’ s most common diseases are connected to h ypertension , also referred to as ‘high blood pr essure’ .
4 GB SA FE T Y I NF OR MA TI ON C aution: consult accompanying documents Type B applied part CE mark: conforms to essential requirements of the Medical Device Directive 93/42/EEC. Disposal: do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary .
GB 5 L CD display signal MEM Pul/min SYS DIA G3 G2 G1 Norm Hypo. Hype. Symbol Description Explanation Systolic blood pressure H igh pr essure result Diastolic blood pressure Low pressure r esult BPM Pulse/minute; heartbeats/minute Memory If “M” shows, the displayed measur ement values is from the memory.
6 GB MO NI TOR COM PO NE NT S L CD DISPLA Y GRADE TIME MEM/UP TOUCH KEY BA T TERY COMP ARTMENT CUFF SYST OLIC SET/DOWN T OUCH KEY DIASTOLIC ST ART/STOP PULSE RA TE Inserting and Changing Batteries 1. Slide off the battery cover . 2. Install the batteries by matching the correct polarity, as shown.
GB 7 SE T T IN G DA T E, TI ME AN D M EA SU RE ME NT UN IT It is impor tant t o set the clock before using your blood pressur e monitor , so that a time stamp can be assigned to each recor d that is stored in the memory. (year: 2000–2050, time: 24 H) 1 .
8 GB HO W TO US E T HE BLOO D P RE SS UR E D E VI CE Applying the cuff 1. Remove all watches, jew eller y , etc. prior to attaching the wrist monitor . Clothing sleeves should be rolled up and the cuff should be wrapped on bare skin for correct measurements.
GB 9 (X) Correct Measuring P osture 1. Place your elbow on a table so that the cuff is at the same level as your heart see Fig . E. NOTE: Y our heart is located slightly below your armpit a bit to the left of the middle of your chest. Relax your entire body , especially the area between your elbow and fingers.
10 GB Important notes regarding your blood pressure measur ement • T ake your reading in a comf ortable environment as measurements can be aected by hot or cold temperatures . T ake your blood pressure at normal body t emperature. • Do not move or talk during measurement as this can elevat e readings.
GB 11 How to measure blood pressur e 1. Press the “ ” to turn on the monitor . 1. When the monit or is turned on the monitor will adjust itself to zero , inflate and will take your measurement automatically . 1. When the measur ement is completed, systolic , diastolic and pulse will be shown simultaneously on the L CD screen.
12 GB Deleting your rec ords If you did not get the correct measurement, you can delete all r esults by the following steps. 1. When the unit is off , hold “MEM” for 3 seconds to enter the deleting menu. The flash display “ dEL ALL ” will show.
GB 13 Cleaning and maintenance The blood pressure monitor and the cu can be wiped with a soft cloth moistened with a mild detergent and wiped dry with a soft, dr y cloth or paper to wel. Never use strong , caustic detergents as these may cause damage to the syn thetic par ts .
14 GB Battery Directive This symbol indicates that batteries must not be disposed of in the domestic waste as they contain substances which can be damaging to the envir onment and health.
GB 15 Pow er supply Battery powered mode: 2*AAA batteries (3V DC) Display mode Digital L CD V .A. 31.5×44mm Measurement mode Oscillographic testing mode Measurement range Pressure: 0–40kpa (0–300mmHg) pulse value: (40–199) times/minute Accuracy Pressure: 5 º C–40 º C within ± 0.
0120 IB-BP W-1 000EU -0912 -01 Register your product today at: http://www.homedicsgroup .com/register HoMedics Group Ltd, HoMedics House Somerhill Business Park, Five Oak Gr een Road T onbr idge , Ken.
An important point after buying a device Homedics BPW-1000-EU (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Homedics BPW-1000-EU yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Homedics BPW-1000-EU - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Homedics BPW-1000-EU you will learn all the available features of the product, as well as information on its operation. The information that you get Homedics BPW-1000-EU will certainly help you make a decision on the purchase.
If you already are a holder of Homedics BPW-1000-EU, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Homedics BPW-1000-EU.
However, one of the most important roles played by the user manual is to help in solving problems with Homedics BPW-1000-EU. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Homedics BPW-1000-EU along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center