Instruction/ maintenance manual of the product RC-1000 Home Automation
Go to page of 16
1 1 RC-1000 Th ermostat Installation Ins tructions DESCRIPTION The RC-1000 is a precision digital thermostat designed for 24 VAC he ating and cooling systems.
2 2 Location When replacing an ex isting thermostat, install the RC-1000 in the same location. If the existing location doesn' t meet the following criteria, choose a n ew location to mount the RC-1000. When choosing a location for the thermostat: 1.
3 3 Connect each wire to the terminal st rip(s) on the thermostat base per the wiring diagram for your system application - See Figures 4 - 7. Form the thermostat wiring so that the ca ble lies flat between the termina l strip(s) and the center of the base - See Figure 2 .
4 4 TYPICAL WIRING DIAGRAMS CA UTION : Do not short gas valve, fan, heat relay, or cool rela y ...even momentaril y. Do not attempt to hook up to live circuits. An accidental connection to a component on the thermostat circuit board could cause damage to the thermostat.
5 5 3. When configured as a co nventional thermostat, by default this the rmostat does not turn the fan on with a call for heat. If the furnace requi res the thermostat to turn the fan on with a call for heat, confi gure the “System Mode” to “Fan On W ith Heat” under “System Options” .
6 6 Single Stage Conventional 24VAC " HOT" Heat 24VAC Com mon* Fan Cool UP 24V AC CONTROL TRANSM FOMER Fan Relay Cool Relay Heat Relay HVAC SYSTEM THERMOSTAT (RC) (C) (Y1) (G) (W1) 1 3 8 6 7 * Common wire is required in “heat only” or “cool only” applications .
7 7 About Heat Pump System s 1) Terminal 5 (O) is energized for coolin g Terminal 6 (B) is energized for heating In most applications, the reversing valve is energiz ed for cooling and should be connected to the "O" terminal.
8 8 Heat Pum p (2 Stage Heat / 1 Stage Cool) 24VAC Common 24VAC "HOT" Auxilirary Heat Compressor Ground Fault Fan Compressor Relay Aux Heat Relay Fan Relay Fault Relay Reversing Valve Energi.
9 9 REMOTE SYSTEM WIRING DIAGRAMS This thermostat has been prepro grammed with energ y saving pro gram schedules in accordance with the ENERGY STAR ® program. W hen used with a remote system, HAI recommends that the Program Mode be configured as “None” or “Occup ancy”.
1 1 0 0 REMOTE SETBACK SWITCH The thermostat can be connected to a remote switch to toggle the desired heat and cool temperature se ttings between preset setpoints.
1 1 1 1 REMOTE TEMPERATURE SENSOR A remote temperature se nsor can be installed to monitor the temperature from a re mote location or can be combined with the onboard temperature sensor for the average temperature of two locations. Run a twisted pair, shielded cable from the RC-10 00 to the remote temperature sensor location.
1 1 2 2 SETUP AND CONFI GURATION NOTE: For proper operation of the features of this thermostat, the Ti me and Date must be set. Even w hen connected to an HAI controller which sets the time and day, the Date must be manually set in the ther mostat under the “S ettings” menu.
1 1 3 3 System Type *Conventional Dual Fuel Heat Pump 1 Heat Pump *Auto Changeover No Fan With Heat Auto Changeover Fan On With Heat Auto Changeover Fan On With Heat Auto Changeover Fan On With Heat M.
1 1 4 4 Cool Mi ni mu m On The number of minutes the thermostat forces the cooling system to remain on before turning off. Raising this number will increase the total time the cooling s y stem is on (saving energ y ), but may allow the temperature to drif t farther from setpoint (decreasing comfort).
1 1 5 5 Auxiliary Heat Diffe rential: This determines how far from the setpoint the temperature has to be b efore the auxiliary heat turns on. This is onl y available for heat pump s y stems.
1 1 6 6 TROUBLESHOOTIN G TIPS SYMP TOM ACTION TO TAKE 1. Check power to the thermostat Thermostat Dead 2. Check wiring diagrams SYMP TOM ACTION TO TAKE 1. Check for break in W or Y wire 2. Allow minimum off time to pass 3. Check sy stem options for correct setting s 4.
An important point after buying a device Home Automation RC-1000 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Home Automation RC-1000 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Home Automation RC-1000 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Home Automation RC-1000 you will learn all the available features of the product, as well as information on its operation. The information that you get Home Automation RC-1000 will certainly help you make a decision on the purchase.
If you already are a holder of Home Automation RC-1000, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Home Automation RC-1000.
However, one of the most important roles played by the user manual is to help in solving problems with Home Automation RC-1000. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Home Automation RC-1000 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center