Instruction/ maintenance manual of the product N10372 Holman
Go to page of 15
INSTRUCTION MANUAL SUIT ABLE FOR INDOOR USE ONL Y OTHERWISE WARRANTY IS VOID IRRIGA TION CONTROLLER 6 S tation Model.
PAGE 1 This unit is available as a 6 station configuration. Designed for residential and light commercial applications, this controller has four separate programs with up to sixteen possible start times a day . This ensures efficient watering of different garden or turf areas.
PAGE 3 Programming Instructions Introduction This controller has been designed with four separate programs, to allow different garden areas to have their own individual watering requirements. A program is basically a method of grouping stations (valves) with similar watering requirements to water on the same days.
PAGE 5 Programming Instructions Programming Instructions Programming Example In this example, the lawn areas , Program 1 ( Group 1 ), are using pop-up sprinklers & require less frequent watering.
PAGE 7 Before proceeding, ensure your watering planner has been completed. From this, you should be aware of which stations are allocated to each program. Note: Set one program at a time - This will ensure that all the values are entered correctly . SETTING PROGRAM 1 - The program number can only be set/changed in the Set Start Times position.
PAGE 9 Programming Odd / Even Day Selection (Optional) In some regions, users are only allowed to water their gardens on, ODD dates if their house number is ODD, or on EVEN dates when their number is EVEN .
PAGE 1 1 Manual Operations Programming Step 3. Set Station Run Times. (Continued) T o adjust the Run time in minutes press next , and use or . T o set the run time in hours, press next and “0” will appear and flash. T o adjust use or . If not required, press next and advance to station 2 by pressing the button.
PAGE 13 Rain Sensor Ready This feature should only be used when a rain sensor has been connected. The controller comes pre-fitted with a socket, ready to take the “HOLMAN” Rain Sensor (P/N CRS1000BC, not included) which has also been pre- fitted with a plug.
Rain Sensor Ready (cont.) DELA Y FEA TURE - When using the Rain Sensor Ready feature, in conjunction with the rain sensor . It is possible to set a delay in the controller to stop the automatic programs from activating too quickly . This feature is applicable to the stations nominated to be controlled by the sensor .
Inst allation Instructions Mounting The Controller This controller unit is an INDOOR MODEL and MUST not be exposed to rain or water ingress. (If the controller needs to be outdoors, you can purchase a HOLMAN outdoor weatherproof box, P/N COBOX, to mount the controller inside.
Inst allation Instructions Power Supply Connections The controller itself can run of f a 240V AC to 24V AC external transformer .. It is recommended that the transformer is not connected to a 240V AC supply which is also servicing or supplying motors (i.
Electrical Characteristics Power Supply MAINS SUPPL Y This unit can run off a 50Hz external transformer , (plugpack), with an output of 24V AC 50Hz @ 1 Amp. Plug Pack Model The correct wiring installation for the 24V AC plug pack is shown on page 19. The plug pack model is only suitable for indoor installation.
Possible Cause Faulty transformer. Fuse blown. Faulty solenoid coil. Incorrect wiring or bad wiring joint. Incorrect programming or blown fuse. Short on keypad or Programming not correct. Short on keypad or too many start times entered on automatic programs.
S pare W atering Planner PAGE 25 PAGE 24 S pare W atering Planner.
Y our Guarantee The manufacturer Guarantee to the original purchaser that any product supplied by the manufacturer will be free from defects in materials and workmanship for a period of three years from the date of purchase.
An important point after buying a device Holman N10372 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Holman N10372 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Holman N10372 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Holman N10372 you will learn all the available features of the product, as well as information on its operation. The information that you get Holman N10372 will certainly help you make a decision on the purchase.
If you already are a holder of Holman N10372, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Holman N10372.
However, one of the most important roles played by the user manual is to help in solving problems with Holman N10372. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Holman N10372 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center