Instruction/ maintenance manual of the product BCC/BCR-140 Henny Penny
Go to page of 39
.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Henny Penny Blast Chiller/Fr eezer BFR/BCR-350 BCC/BCR-175 BCC/BCR-140.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 LIMITED W ARRANTY FOR HENNY PENNY APPLIANCES Subject to the following conditions, Henny Penny Corporation makes the following limited warranties.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 T ABLE OF CONTENTS Section Page Section 1. INTRODUCTION ................................................................................................................... 1- 1 1-1. Henny Penny Blast Chiller .
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 1-1 SECTION 1. INTRODUCTION 1-1. BLAST CHILLER/ The Henny Penny Blast Chiller are designed to carry out fast refrigeration of food products. The units are electronically con- trolled for easy use and for consistent operation.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 1-5. SAFETY The Henny Penny Blast Chiller has may safety features incorpo- rated. However , the only way to ensure a safe operation is to fully understand the proper installation, operation, and maintenance procedures.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 2. INST ALLA TION 2-1. INTRODUCTION This section provides the installation for the Henny Penny Blast Chiller . NOTE Installation of this unit should be performed only by a qualified service technician.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 (Continued) 2-2 201 2-2. UNP ACKING 4. Open door and remove packing from the inside of the unit. 5. Peel off any protective covering from the exterior of the cabinet. 6. Y our Blast Chiller is now ready for operation.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 2-3 2-3. ELECTRICAL Refer to the table below for electrical ratings for both models. (Continued) Model No.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 2-5. REFRIGERANT INFORMA TION Design Pressure Refrigerant T ype Amount of Refrig. High Low BCC-140 R404A 6 lbs. (2.7 kg) 406 psig 102psig (28 bar) (7 bar) BCC-175 R404A 5.5 lbs. (2.4 kg) 406 psig 102 psig (28 bar) (7 bar) 2-6.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 3. OPERA TION 3-1. INTRODUCTION This section provides operating procedures for the Blast Chiller . Sections 1, 2, and 3 should be read, and all instructions should be followed before operating the cabinet.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-2. OPERA TING CONTROLS (Continued) Fig. Item Description Function No. No. 3 - 1 7 Select Button The Select button is used to choose between a timing cycle or a cycle using the food probe. 3 - 1 8 Fan LED The Fan LED is a green light which illuminates when the fan is running.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-3 100.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-3. BASIC OPERA TION The Henny Penny Blast Chillers can chill food products with a core temperature of 149ºF (65ºC), down to 40ºF (4ºC) within 4 hours (room ambiant temperature may impact time it takes to reach the desired temperature).
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-3. BASIC OPERA TION 5. Press the Select button to choose the food probe mode or the timing mode. With the Frigiprobe mode selected, the digital display will alternately show the core temperature of the product, and the elapsed time of the cycle.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-3. BASIC OPERA TION A temperature conversion chart is provided for your (Continued) convenience: 200 3-6.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-4. DE-ICING Henny Penny recommends to perform the de-icing process after every 3 cycles, and at the end of each day . This will eliminate any ice that may have formed around the evaporator during the chilling cycle.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-5. CLEANING Daily: 1 . Remove all electrical power supplied to the unit by turning off the wall circuit breaker . 2 . Remove all product from the unit. 3. Remove the racks and pans from the unit and clean with soap and water at a sink.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-5. CLEANING (Continued) 3. Use a vacuum cleaner , or soft brush to remove the dust, or other obstructions from the condenser . 4 . Finish cleaning with compressed air if possible. DO NOT use a wire brush to clean the condenser , or damage to the condenser could result.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING Information about the operation settings can be accessed by pressing the Alarm button.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING The holding temperature can be changed at this time by (Continued) using the Up and Down buttons. Factory setting for air temperature is 37ºF (3ºC). The minimum temperature setting is 32ºF (0ºC), and the maximum temperature is 50ºF (10ºC).
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING 1 1. The duration of time the temperatures, (in 9 and 10 (Continued) above), must remain at before the alarms will sound. Press the Alarm button 1 1 times and the digital display will 10 show the time at which the high and low temperatures (no.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING 14. Blast chilling, low side air temperature limit, when using the Frigiprobe, in step 12 of this section. Press the Alarm button 14 times and the low side air temperature, at which 20 the compressor cycles on and off, will show in the display .
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 3-7. PROGRAMMING 17. Frigiprobe temperature for when the buzzer sounds at (Continued) the start of a cycle.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 SECTION 4. TROUBLESHOOTING 4 - 1. INTRODUCTIO N This section provides troubleshooting information in the form of an easy to read table. If a problem occurs during the first operation of a new cabinet, recheck the installation per section 2 of this manual.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4-2. TROUBLESHOOTING (Continued) Display Cause Correction AL-5 T emperature too low in the hold mode. Faulty control board - replace control board. Faulty contactor - replace contactor . AL-6 T emperature too high in the hold mode.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4-2. TROUBLESHOOTING (Continued) Problem Cause C or re c ti o n Slow to decrease Condenser obstructed by dirt. Clean the Condenser . in temperature (decline in performance) Evaporator iced up. Perform a de-icing cycle.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4-2. TROUBLESHOOTING (Continued) Problem Cause C or re c ti o n Green compressor indicator V oltage across terminals 10-1 1 light off and compressor of control board: i s wo rk in g . - Control board relay bad Replace control board.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 4-5 100.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 5-1.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 5-2 201.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 201 5-3.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Quantity BFR/ Item BCC BC R BCC B C R B C R No . Part No. Description 14 0 14 0 17 5 1 75 3 50 1 9504.0205 Control PC Boar d 11111 2 9503.3692 Display PC Board 11111 3 9503.3700 Auxiliary Display Board 11111 4 9503.
Henny Penny Model BCC/BCR-140, BCC/BCR-175, BFR/BCR-350 Quantity BFR/ Item Part BC C B C R B C C B C R B C R N o . No . Description 14 0 14 0 17 5 17 5 35 0 31 9500.8967 Nozzle-Expansion V alve BFR-350 ---- 2 32 9500.7993 W ater Pressure V alve - BCC-175 - - 1 - - 33 9503.
.
1. General Services 100 Hicks Ave. Medford, MA 02155 (800) 233-1033 2. Art Cole Associates Golden Street Industrial Park Meriden, CT 06450 (203) 237-7177 3. Globe-Monte Metro, Inc. 47-02 Metropolitan Avenue Ridgewood, NY 1 1385 (718) 786-5760 4. Guertin Dist.
.
U.S. Headquarters Henny Penny Corporation 1219 U.S. Route 35 West Eaton, OH 45320 USA T elephone: 937-456-8417 Fax: 937-456-1860 Representative Office 1 .
Lebanon 40. Pro Kitchen Cahlfoun Building Kaslik - Main Road PO Box 1066 Jounieh Lebanon T elephone: 961-9-635-077 Fax: 961-9-635-059 Lithuania 41. Master Group Baltic Master Dariaus Ir Girena 175 2038 Vilnius, Lithuania T elephone: 3702-306-528/529 Fax: 3702-306-533 Malaysia 42.
An important point after buying a device Henny Penny BCC/BCR-140 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Henny Penny BCC/BCR-140 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Henny Penny BCC/BCR-140 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Henny Penny BCC/BCR-140 you will learn all the available features of the product, as well as information on its operation. The information that you get Henny Penny BCC/BCR-140 will certainly help you make a decision on the purchase.
If you already are a holder of Henny Penny BCC/BCR-140, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Henny Penny BCC/BCR-140.
However, one of the most important roles played by the user manual is to help in solving problems with Henny Penny BCC/BCR-140. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Henny Penny BCC/BCR-140 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center