Instruction/ maintenance manual of the product IMPERIAL "S" Hatco
Go to page of 40
Electric Booster W ater Heaters Imperial “S” Comp act “C” Mini-Comp act “MC” Series Inst allation & Operating Manual I&W #07.05.001.00 This manual contains import ant safety information concerning the maintenance, use and operation of this product.
Form No. EBOOSTERM-0406 i CONTENTS INTRODUCTION Hatco Electric Booster W ater Heaters are designed for use with commercial dishwashers to boost the temperature of the regularly available hot water , usually 1 10°-150°F (43°-66°C) up to 180°F (82°C).
Form No. EBOOSTERM-0406 1 IMPORT ANT SAFETY INFORMA TION W ARNINGS T o avoid personal injury or damage to equipment, the booster heater must be inst alled by qualified, trained installers. Inst allation must conform to all local electrical and plumbing codes.
Form No. EBOOSTERM-0406 2 IMPORT ANT SAFETY INFORMA TION IMPORT ANT! Read the following important safety instructions to avoid personal injury or death, and to avoid damage to the equipment or property . W ARNINGS V alves supplied by Hatco are designed for high temperature commercial operation.
Form No. EBOOSTERM-0406 3 IMPORT ANT SAFETY INFORMA TION IMPORT ANT! Read the following important safety instructions to avoid personal injury or death, and to avoid damage to the equipment or property .
Form No. EBOOSTERM-0406 4 MODEL DESCRIPTIONS ALL MODELS Hatco Electric W ater Booster Heaters are available in three models: Imperial, Compact and Mini- Compact.
Form No. EBOOSTERM-0406 5 SPECIFICA TIONS kW V olts* Phase Amp Draw Breaker or Copper Conduit L1 L2 L3 Fuse Size Wire Size Size 4 208 1 19 19 - 30 10 1/2" (13 mm) 240 1 17 17 - 30 10 1/2" (1.
Form No. EBOOSTERM-0406 6 SPECIFICA TIONS Wire size is based on THHN wire for branch circuit protection at .91 derate factor . Circuit breakers and fused disconnects are to be mounted remote and wired by contractor . Sizes are based on the 2002 NEC table 310-16.
Form No. EBOOSTERM-0406 7 SPECIFICA TIONS kW V olts* Phase Amp Draw Breaker or Copper Conduit L1 L2 L3 Fuse Size Wire Size Size 36 208 1 173 173 - 225 4/0 1-1/2" (38 mm) 208 3 100 100 100 125 1 1-1/4" (32 mm) 240 1 150 150 - 200 3/0 1-1/2" (38 mm) 240 3 86.
Form No. EBOOSTERM-0406 8 SPECIFICA TIONS SIZING CHART FOR LOW-TEMP DISHMACHINES BOOSTERS RA TED A T 30°F (16°C) RISE Dishwasher Model Number Electric Comp act Imperial Booster Booster American Dish.
Form No. EBOOSTERM-0406 9 SPECIFICA TIONS SIZING CHART FOR LOW-TEMP DISHMACHINES (CONTINUED) BOOSTERS RA TED A T 30°F (16°C) RISE Dishwasher Model Number Electric Comp act Imperial Booster Booster Jackson Conserver 24L T , 200L T , ES1000, (Ecolab/Jackson) .
Form No. EBOOSTERM-0406 10 SPECIFICA TIONS BOOSTER HEA TER SIZING CHART ELECTRIC ELECTRIC COMP ACT BOOSTER IMPERIAL BOOSTER Dishwasher Model Number T emperature Rise T emperature Rise 40°F (22°C) 70°F (39°C) 40°F (22°C) 70°F (39°C) Adamation CSL-1390, CA-2, CA-3, CA-4, SLAP 44 .
Form No. EBOOSTERM-0406 11 SPECIFICA TIONS BOOSTER HEA TER SIZING CHART (CONTINUED) ELECTRIC ELECTRIC COMP ACT BOOSTER IMPERIAL BOOSTER Dishwasher Model Number T emperature Rise T emperature Rise 40°F (22°C) 70°F (39°C) 40°F (22°C) 70°F (39°C) CMA Dishmachines CMA-180 .
Form No. EBOOSTERM-0406 12 SPECIFICA TIONS BOOSTER HEA TER SIZING CHART (CONTINUED) ELECTRIC ELECTRIC COMP ACT BOOSTER IMPERIAL BOOSTER Dishwasher Model Number T emperature Rise T emperature Rise 40°F (22°C) 70°F (39°C) 40°F (22°C) 70°F (39°C) Jackson JP-24, JP-24B, JP-24F , JP-24BF .
Form No. EBOOSTERM-0406 13 SPECIFICA TIONS BOOSTER HEA TER SIZING CHART (CONTINUED) ELECTRIC ELECTRIC COMP ACT BOOSTER IMPERIAL BOOSTER Dishwasher Model Number T emperature Rise T emperature Rise 40°F (22°C) 70°F (39°C) 40°F (22°C) 70°F (39°C) S tero SCT -44-10-L W , SCT -44-L W , SCT -66S-L W , SCT -76S-L W , SCT -76SC-L W , SCT-90S-L W .
Form No. EBOOSTERM-0406 14 SPECIFICA TIONS CAP ACITY - IMPERIAL “S” SERIES S torage capacity is 16 gallons (61 liters). Model kW 40°F (22°C) Rise 70°F (39°C) Rise Shipping Weight S-6 6 60 gph (227 lph) 34 gph (129 lph) 200 lbs. (91 kg) S-7 7 70 gph (265 lph) 40 gph (151 lph) 200 lbs.
Form No. EBOOSTERM-0406 15 SPECIFICA TIONS DIMENSIONS - IMPERIAL “S” SERIES DIMENSIONS - COMP ACT “C” SERIES 4 to 18 kW DIMENSIONS - COMP ACT “C” SERIES 24 to 57 kW.
Form No. EBOOSTERM-0406 16 SPECIFICA TIONS DIMENSIONS - MINI-COMP ACT “MC” SERIES INST ALLA TION LOCA TION For the most effective operation, inst all the booster heater as close as possible to the commercial dishwasher . The location must have a solid foundation along with being clean and dry .
Form No. EBOOSTERM-0406 17 INST ALLA TION ALL MODELS Booster Heaters are shipped with most components pre-assembled. Care should be taken when unpacking shipping carton to avoid damage to unit and components enclosed. Component s are shipped with the heater unit.
Form No. EBOOSTERM-0406 18 INST ALLA TION Figure 7. Components Shipped with the Heater Unit Leg Mounting Bracket s with Hardware T emperature/Pressure Gauge T emperature Pressure Relief V alve One set of four legs supplied with all Imperial and Mini- Compact Booster Heaters.
Form No. EBOOSTERM-0406 19 INST ALLA TION W ARNING T o assure proper operation and avoid a possible unsafe condition, the booster heater must be inst alled in a horizontal position with the base p arallel to the floor and the inlet connection at the lowest point.
Form No. EBOOSTERM-0406 20 INST ALLA TION CAUTION T o assure proper operation do not use an anti- siphon or check valve on the incoming water line. PRESSURE REDUCING V AL VE CAUTION If water supply pr.
Form No. EBOOSTERM-0406 21 INST ALLA TION Inlet Refer to Figure 8, 9, 10, 1 1 or 12. 1. Connect the booster water inlet to a hot water supply line from the regular water heater . W ater temperature from the regular water heater should be 1 10° or 140°F (43° or 60°C) and should not exceed 160°F (71°C).
Form No. EBOOSTERM-0406 22 INST ALLA TION Figure 10. Plumbing Connections - Compact Series 4-18 kW Figure 9. Plumbing Connections - T wo Imperial Models Connected in Series T emperature/Pressure Gauge 3/4" Gate or Ball V alve * Discharge from T/P Relief V alve.
Form No. EBOOSTERM-0406 23 INST ALLA TION Figure 12. Plumbing Connections - Mini-Compact Models Figure 13. Booster Heaters with optional Back Pressure V alve T emperature/Pressure Gauge 3/4" Gate or Ball V alve * T emperature/Pressure Gauge Discharge from T/P Relief V alve.
Form No. EBOOSTERM-0406 24 INST ALLA TION W ARNING Hatco has always endorsed the use of safety equipment when using a booster water heater or storage-type water heater . Hatco booster heaters are shipped with a temperature/pressure relief valve at no extra charge.
Form No. EBOOSTERM-0406 25 INST ALLA TION ELECTRICAL-ALL SIZES AND VOL T AGES General Hatco Electric Booster W ater Heaters are available for operation on standard power systems.
Form No. EBOOSTERM-0406 26 OPERA TION On/Off Switch Indicator Light Figure 17. Controls-Imperial and Compact Models SYSTEM ST ART -UP W ARNING W ater in the unit is very hot. Wear protective gloves and proper attire when operating to avoid injury . 1.
Form No. EBOOSTERM-0406 27 MAINTENANCE Figure 19. Thermost at Adjustment GENERAL W ARNING T o avoid any injury or damage to the booster heater turn the power OFF at the disconnect switch/circuit breaker and allow to cool before performing any maintenance or adjustment s.
Form No. EBOOSTERM-0406 28 MAINTENANCE BLENDED PHOSPHA TE TREA TMENT SYSTEM (OPTIONAL) The Blended Phosphate W ater T reatment System reduces mineral scale by introducing a measured amount of polyphosphate into the water . Cartridges supplied have a usage rating of 100,000 gallons (378,541 liters) of water .
Form No. EBOOSTERM-0406 29 ACCESSORIES Figure 21. Optional S tainless S teel Adjustable Legs ST AINLESS STEEL ADJUST ABLE LEGS 1. Carefully place unit on its side. CAUTION Do not lay unit on the side with the control p anel or damage to unit could occur .
Form No. EBOOSTERM-0406 30 TROUBLESHOOTING W ARNING T o avoid any injury or damage, the booster heater must only be serviced by qualified personnel. W ARNING T o avoid any injury or damage to the booster heater turn the power OFF at the disconnect switch/circuit breaker and allow to cool before performing any maintenance.
Form No. EBOOSTERM-0406 31 TROUBLESHOOTING W ater reaches 180°F (82°C) but does not last through the entire dishwasher operation. Low incoming water temperature. Incoming water temperature drops. Flow pressure is too high. Booster heater may be undersized.
Form No. EBOOSTERM-0406 32 TROUBLESHOOTING W ARNING T o avoid any injury or damage, the booster heater must only be serviced by qualified personnel. W ARNING T o avoid any injury or damage to the booster heater turn the power OFF at the disconnect switch/circuit breaker and allow to cool before performing any maintenance.
Form No. EBOOSTERM-0406 33 TROUBLESHOOTING T emperature limit set too low . Thermostat set too high. Incoming water temperature too high causing nuisance tripping of high temperature limit switch. Loose connections or wire connection has insulation under crimp.
Form No. EBOOSTERM-0406 34 HA TCO LIMITED W ARRANTY 1. PRODUCT W ARRANTY Hatco warrants the product s that it manufactures (the “Products”) to be free from defect s in materials and workmanship, u.
Form No. EBOOSTERM-0406 35 NOTES.
Form No. EBOOSTERM-0406 36 NOTES.
Form No. EBOOSTERM-0406 37 NOTES.
HA TCO CORPORA TION P .O. Box 340500, Milwaukee, WI 53234-0500 U.S.A. (800) 558-0607 (414) 671-6350 Parts & Service Fax (800) 690-2966 Int’l. Fax (414) 671-3976 www .hatcocorp.com HA TCO AUTHORIZED P ARTS DISTRIBUT ORS Printed in U.S.A. April 2006 ALABAMA Jones McLeod Appl.
An important point after buying a device Hatco IMPERIAL "S" (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Hatco IMPERIAL "S" yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Hatco IMPERIAL "S" - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Hatco IMPERIAL "S" you will learn all the available features of the product, as well as information on its operation. The information that you get Hatco IMPERIAL "S" will certainly help you make a decision on the purchase.
If you already are a holder of Hatco IMPERIAL "S", but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Hatco IMPERIAL "S".
However, one of the most important roles played by the user manual is to help in solving problems with Hatco IMPERIAL "S". Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Hatco IMPERIAL "S" along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center