Instruction/ maintenance manual of the product 001050 Haier
Go to page of 24
No.00105 0 SPLIT TYPE ROOM AIR CONDITIONER OPERA TION MANUAL Please read this operation manual before using the air conditioner HSU-09LH13 HSU-12LH13.
Bef ore disposing an old air conditioner that goes out of use, please mak e sure it's inop- erativ e and saf e. Unplug the air conditioner in order to av oid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require speciali- zed w aste disposal.
Do not obstruct or cov er the ventilation grille of the air conditoner .Do not put fingers or any other things into the inlet/outlet and s wing louver . Do not allow children to pla y with the air conditioner .In no case should children be allow ed to sit on the outdoor unit.
Cautions STRICT ENFORCEMENT Safety Instruction Installation W ARNING Please read the f ollowing Safety Instructions carefully prior to use. The instructions are classified into two le vels , W ARNING and CA UTION according to the seriousness of possible risks and damages as follo ws.
Cautions W ARNING When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. OFF Use an exclusive power source with a circuit breaker ENFORCEMENT Connect power supply cord to the outlet completely Use the proper voltage Do not use power supply cord in a bundle.
1 2 3 4 Indoor unit Outdoor unit P ar ts and Functions 5 OUTLET CONNECTING PIPING AND ELECTRICAL WIRING INLET DRAIN HOSE Actual inlet grille may vary from the one shown in the manual according to the product purchased Displa y board Inlet Anion generator V er tical flap (Use remote controller to adjust up and down air flo w .
P ar ts and Functions Used to select CODE A or B with a press ,A or B will be display ed on LCD . Please select A without special e xplanation. 1.CODE When the remote controller appears abnormal, use a sharp pointed ar ticle to press this button to reset the remote controller normal.
Remov e the batter ies in case unit won't be in usage f or a long per iod. If there are any displa y after taking-out, just need to press reset ke y .
Operation Remote controller 8 STERILIZE 2.Health anion function Air conditioner starts health anion function operation. For twice press, disappears,the operation stops.
A uto Operation Operation Remote controller 9 STERILIZE About Auto Oper ation Under the mode of auto operation, air conditioner will automatically select Cool or Dry operation according to room temperature and setting temperature. 5.Unit stop Press ON/OFF button, the unit stops .
Cool Operation Remote controller 2.Select operation mode Press F AN button. For each press, fan speed changes as follows: Press MODE button. For each press, operation mode changes as follows: Remote controller: Remote controller: Then Select COOL operation Press TEMP .
2.Select operation mode Press F AN button. For each press , f an speed changes as f ollows: Press MODE button. For each press , operation mode changes as f ollows: Remote controller : Remote controller : Then Select DR Y operation Press TEMP . button Every time the button is pressed, temp .
F an Operation 2.Select operation mode Press F AN button. For each press , fan speed changes as f ollows: Press MODE button. For each press , operation mode changes as f ollows: Remote controller : Remote controller : Then Select F AN operation 3.Fan speed selection 4.
2.Up and down air flo w direction V er tical flap P os.1 P os.1 P os.2 P os.3 P os.4 P os.6 P os.1 P os.2 P os.3 P os.4 P os.5 P os.6 P os.2 P os.3 P os.
If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change. 4.Set the wind speed change when sleeping Bef ore going to bed, you can simply press the SLEEP b utton and unit will operate in SLEEP mode and bring you a sound sleep .
Remote Controller T imer On/Off Operation Operation Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
Remote Controller T imer On-Off Operation Operation Just press TIMER button several times until TIMER mode disappears. According to the T ime setting sequence of TIMER ON or TIMER OFF , either Start-Stop or Stop-Start can be achieved. Set clock correctly before starting TIMER operation.
Operation 19 When the remote controller is manipulated, it gets the system back to the nor mal operation mode . Emer g ency and T est Operation When machine is r unning in emergency , the set value of temper ature and wind speed couldn't be altered; meanwhile, it can't operate f or dehumidifying or under timing mode.
For Smar t Use of The Air Conditioner Setting of proper room temperature Close doors and windo ws dur ing oper ation If the unit is not to be used f or a long time, turn off the po wer supply main s witch.
For Smar t Use of The Air Conditioner W ARNING Air Filter cleaning Open the inlet grille by pulling it upw ard. Remov e the filter . Clean the filter . Attach the filter . Close the inlet grille. Push up the filter's center tab slightly until it is released from the stopper , and remov e the filter downw ard.
Maintenance Replacement of Air Purifying Filter 1.Open the lnlet Grille 2.Detach the standard air filter 3.Detach old Air Pur ifying Filter Detach old Air Purifying Filter 4.Attach old Air Pur ifying Filter 5.Attach the standard air filter (Necessar y installation) 6.
T o K eep Y our Air conditioner in Good Condition after Season. Operate in cooling mode f or 2-3 hours. Put of f the pow er supply cord. T ak e out the batter ies from the wireless remote controller .
Bef ore Setting in High season Cleaning the standard air filter . Connecting the ear thing cab le. Do not b loc k the air inlet or outlet. Plug-in Caution Caution After brush awa y dust at the plug, inser t the plug of the pow er supply cord into the outlet completely .
Is the air filter dir ty? Normally it should be cleaned e very 15 days . Are there any obstacles bef ore inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is t.
An important point after buying a device Haier 001050 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Haier 001050 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Haier 001050 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Haier 001050 you will learn all the available features of the product, as well as information on its operation. The information that you get Haier 001050 will certainly help you make a decision on the purchase.
If you already are a holder of Haier 001050, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Haier 001050.
However, one of the most important roles played by the user manual is to help in solving problems with Haier 001050. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Haier 001050 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center