FOR VEHICULAR SLIDE GATES INSTALLATION MANUAL FOR THE PROFESSIONAL INSTALLER
This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO, Inc. from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate opener. This gate opener produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate openers are intended for use on vehicular gates only.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate opener safety,
as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
DO NOT INSTALL THIS OPERATOR WITHOUT SAFETY EDGES AND ROLLER GUARDS!
RB270 rev - 01/03/03

GTO PRO SL-1000 and SL-2000 series automatic gate operators are intended for use with vehicular slide gates. These operators can be used in Class I, Cass II and Class III applications.
Residential Vehicular Gate Operator-Class I: A vehicular gate operator (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith.
Commercial/General Access Vehicular Gate Operator-Class II: A vehicular gate operator (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.
Industrial/Limited Access Vehicular Gate Operator–Class III: A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
Restricted Access Vehicular Gate Operator–Class IV: A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public, in which unauthorized access is prevented via supervision by security personnel.
Converting Metric Units to English Equivalents When You Know Multiply By To Find Symbol
centimeters 0.3937 inches in. (or ") meters 3.2808 feet ft. (or ') kilograms 2.2046 pounds lb. (or #)
Converting English Units to Metric Equivalents When You Know Multiply By To Find Symbol
inches 2.5400 centimeters cm feet 0.3048 meters m pounds 0.4535 kilograms kg
Temperature deg. Celsius (ºC x 1.8) + 32 deg. Fahrenheit ºF deg. Fahrenheit (ºF-32) / 1.8 deg. Celsius ºC



AUTOMATIC SLIDE GATE OPERATORS
Because automatic gate operators produce high levels of force, all system designers, installers, and consumers have an obligation to know the potential hazards associated with improperly designed, installed, or maintained gate operator systems. Keep in mind that the gate operator is just one component of the total gate operating system. Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the system designer, installer, and consumer. Because there are many possible applications of the gate operator, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.
The precautions and warnings in this manual are identified with this warning symbol.
The symbol identifies the conditions that can result in damage to the operator or its components, serious injury, or death.
Because GTO automatic gate operators are only part of a total gate operating system, it is the responsibility of the designer, installer, and purchaser to ensure the total system is safe for its intended use. Bypassing safety devices or neglecting to use safety devices with the gate operator is NOT acceptable.

To prevent unauthorized removal of the quick release pins, install pin locks (see accessory catalog) above the quick release pins in both chain brackets.

FOR THE SYSTEM DESIGNER WARNING: To reduce the risk of injury or death:
I. Before Installation
II. During Installation

III. After Installation

As specified by Underwriters Laboratories Inc. UL 325 (31.1.1), automatic gate operators shall have provisions for, or be supplied with, at least one independent primary and one independent secondary means to protect against entrapment. GTO gate operators utilize Type A, an inherent entrapment sensing system, as the primary type of entrapment protection. The GTO/PRO SL-1000/2000 and GTO/PRO SL-1000B/2000B gate operators have provisions for the connection of Type B1 and B2 protection to be used as the secondary type of entrapment protection.
A. Refer to the sensor manufacturer’s instructions on the placement of non-contact sensors for each type of application. B. Care shall be exercised to reduce the risk of nuisance tripping, such as when a vehicle trips the sensor while the gate is still moving. C. One or more non-contact sensors shall be located where the risk of entrapment or obstruction exists, such as the perimeter reachable by a moving gate or barrier.
A. One or more contact sensors shall be located at the leading edge, trailing edge, and post mounted edge, both inside and outside of a vehicular slide gate system.
B. A hard wired contact sensor shall be located and its wiring arranged so that the communication between the sensor and the gate operator is not subjected to mechanical damage. C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.
ENTRAPMENT ALARM (UL 325; 31.2.1) The GTO/PRO SL-2000 and GTO/PRO SL-2000B operators are designed to stop and reverse for 2 seconds when the gate comes in contact with an obstruction or when an object activates the non-contact sensors. Additionally, these operators are equipped with an audio entrapment alarm which will function if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes or until the operator receives an intended signal (e.g., transmitter signal) and the gate returns to a fully open or fully closed position.
STATUS STATUS BATT + –
PWR. SW.
OBSTR. SENS.
CLS EDG
OPN EDG
GRN
ORG
BLU
WHT
R G B
CLS EDG
OPN EDG
RED
BLK
ORG
BLU
GRN
RED
BLK
ORG
BLU
GRN
ACCESSORY
RCVR
ALARM SECOND OPERATOR FIRST OPERATOR POWER IN
18VAC SOLAR ~ ~ – +
Entrapment Alarm (bottom right of control box)

FOR THE CONSUMER/END USER WARNING: To reduce the risk of injury or death:

INSTALL SCREEN GUARD OVER GATE AND FENCE Injuries may occur when people place their hands, arms, legs, etc., through openings in the gate grill when the gate is operated, trapping them between the grill and the fence post (or fence). All openings of a horizontal slide gate must be guarded or screened to prevent a 21/4” diameter sphere from passing through openings anywhere in the gate. This screen/guard must also be installed over the portion of adjacent fence that the gate covers in the open position. Screening will prevent access through openings in areas where the gate may travel.
Contact Sensor Screen Mesh Contact Sensor Contact Sensor

ROLLER GUARDS Injuries occur when people get their hands caught between the gate and the roller. Roller guards or enclosed tracks must be installed to prevent this pinch point hazard.

Moving Gate Can Cause
WARNING SIGNS The warning signs (above right) must be installed on both sides of the gate (see page 7 for details).
ENTRAPMENT PROTECTION GTO’s internal obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily injury. For this reason, safety devices such as safety edges MUST be installed. Furthermore, a pedestrian gate must be installed if walk-through traffic is expected near the gate. We recommend the GTO Bulldog Pedestrian Gate Lock (see accessory catalog) for controlled access.

Contact Sensor · Injury Or Death

These warning labels should be found at the locations specified below. If any of them are missing, immediately contact your installer for replacements.
WARNING !
Conforms to UL 325 STANDARDS Certified to CAN/CSA-C22.2 No.247-92
Maximum Gate: 500 lb. (226.7 kg); 30 ft. (9.1 m) Voltage: 12 Vdc; Frequency: 0 Hz; Power: 93.2 W Class I, II and III Vehicular Slide Gate Operator Serial Number: SL1000-xxxxxxx
Disconnect operator ONLY when the gate is NOT moving.
TO MANUALLY OPEN AND CLOSE THE GATE: 1. Lift quick release pins UP, then pull them OUT of chain brackets. 2. Lay chain down and manually slide gate to desired position.
GTO, Inc. Tallahassee, Florida USA
Conforms to UL 325 STANDARDS Certified to CAN/CSA-C22.2 No.247-92
Maximum Gate: 1000 lb. (453.4 kg); 30 ft. (9.1 m) Voltage: 12 Vdc; Frequency: 0 Hz; Power: 93.2 W Class I, II and III Vehicular Slide Gate Operator Serial Number: SL2000-xxxxxxx
Disconnect operator ONLY when the gate is NOT moving.
TO MANUALLY OPEN AND CLOSE THE GATE: 1. Lift quick release pins UP, then pull them OUT of chain brackets. 2. Lay chain down and manually slide gate to desired position.
GTO, Inc. Tallahassee, Florida USA
product identification and manual operation instruction label installed on control box cover

Continued from page 7
These warning labels should be found at the locations specified below. If any of them are missing, immediately contact your installer for replacements.
Injury Or Death

OPERATIONAL CAPACITY • The GTO/PRO SL-1000 and GTO/PRO SL-1000B will handle gates weighing up to 500 lb. (226.7 kg) and up to 30 ft. (9.14 m) in length (per leaf) if the proper installation procedures have been followed. Note that ball bearing rollers and covers should be used on all gates.
Gate Capacity Chart for SL-1000 Series (estimated number of cycles based on use with a transformer)
Cycles shown are for single gate, dual gates will get approximately half as many cycles.
Housing Dimensions: Height: 18" Width: 211/2" Depth: 11" Shipping Weight: Approximately 90 lb.
Rollers should be lubricated at least four times per year. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Gate Opening · Gate Weight

OPERATIONAL CAPACITY • The GTO/PRO SL-2000 and GTO/PRO SL-2000B will handle gates weighing up to 1000 lb. (453.4 kg) and up to 30 ft. (9.14 m) in length (per leaf) if the proper installation procedures have been followed. Note that ball bearing rollers and covers should be used on all gates.
Gate Capacity Chart for SL-2000 Series (estimated number of cycles based on use with a transformer)
20 ft. 16 ft. 12 ft. 8 ft.
80 100 120 140 400 lb.
70 90 110 130 600 lb.
60 80 100 120 800 lb.
50 70 90 110 1000 lb.
Cycles shown are for single gate, dual gates will get approximately half as many cycles.
Housing Dimensions: Height: 18" Width: 211/2" Depth: 11" Shipping Weight: Approximately 90 lb.
Rollers should be lubricated at least four times per year. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE.
Gate Opening · Gate Weight


18 Vac Transformer 120 Volt (RB570) GTO Transmitter (RB740)
(2) 2” square x 48” long legs (206IH)

(4) 1/4”-20 x 1/2” Screws
(4) 3/8”-16 x 2” diameter U-Bolts and (8) 3/8” Serrated Nuts (RB210)
(4) 3/8” -16 x 3” Carriage Bolts (RB659)


Be sure the gate is properly installed and slides smoothly before installing the GTO/PRO Slide Gate Operator. The gate must be plumb, level, and move freely. The gate must not bind or drag on the ground. Never use a wheel on the gate, because the additional drag and resistance can cause the operator to obstruct.
The diagram below shows a single slide gate installation with recommended safety features. The operator must be installed on the inside of the gate. GTO requires using safety edges and roller guards to help reduce the possibility of bodily injury.

Run 1000' (max.) of low voltage wire to control box from transformer (wire not included).
Use PVC Conduit (not included)
for power cables.
Contact Sensor

Run the low voltage wire and receiver wire through PVC conduit into the slider unit to protect it from lawn mowers, weed eaters, grazing animals, etc. PVC conduit should be used for accessory wires such as loop detectors, key pads, card readers or any other entry device.

Separate PVC Cond for power, receiver and control wiring.
Separate PVC Conduits for power, receiver and control wiring.
Conduit through the concrete pad.
Conduit around the concrete pad.
MOUNTING THE LEGS ON THE SLIDE GATE OPERATOR

STEP 1 Mount the legs on the slide gate operator using the 3/8” x 3” Carriage Bolts, 3/8” Flat Washers, 3/8” Lock Washers, and 3/8” Nuts. See Illustration A.

DETERMINING THE MOUNTING POSITION AND MOUNTING THE OPERATOR

STEP 2 Install chain brackets at each end of the gate on the inside (operator side) of the gate (see Overview Illustration, page. 12). Position the tops of chain brackets no more than 6” above the bottom corners of the gate frame and secure with U-bolts (see Illustration B). The chain brackets will work on gate frames 13/4" to 21/2" in diameter or square tube gates. The U- bolts provided will work on 2" diameter pipe gate frames.

position bracket so that string will be approximately 7" to 10" from ground level at the point where the operator will be mounted
STEP 3 Insert a quick release pin into the center slot in each of the chain brackets (see Illustration C). Tie a string to the end of each quick release pin so that the string is tight between the two chain brackets (the string will be used to align the operator). The string should be 7”-10” from the ground (see Illustration B). The chain brackets can be adjusted up or down on the gate to achieve the proper height. The goal here is to set the height of the operator so that when the housing is in place it will clear the ground by 1” to 4” (see Illustration E).
Center point between posts
Fence Post Fence Post
Operator (centered between post)
STEP 4 Find the center point between the two roller/fence posts (see Illustration D). This should coincide with the position of the center point of the operator. Dig a hole approximately 12” x 28” wide x 28” deep. Place the operator in the hole on its legs and position the bottom idler sprockets on the top of the string and level the unit (see Illustration E). Make sure operator is level and plumb. With the unit level and in place, pour the concrete and let set for 24 hours (checking the level periodically) before proceeding to the next step.
String 7" to 10" above ground
BEFORE POURING CONCRETE: 1] Make sure operator is centered between roller posts and aligned with string; and, 2] Determine method of installing conduit for wiring (see page 13)!
1" to 4" clearance

STEP 5 After the concrete has hardened, remove the string from the quick release pins. Attach the chain to one quick release pin with a master link (see Illustration F). Run the chain through the chain sprockets (see Illustration G).
STEP 6 Pull the chain to the second chain bracket leaving approximately four inches of slack (see Illustration G). Do not pull chain tight; a tight chain will interfere with the operation of the operator. Mark the chain where it meets the second quick release pin.
WARNING !
Allow 1" of slack for every 10' of chain
STEP 7 Drive the pin out of the chain link using a tool such as a punch or chain break. Connect the chain to the second quick release pin using a master link (see Illustration H).

To prevent unauthorized removal of the quick release pins, install pin locks (see accessory catalog) above the quick release pins in both chain brackets.

Make sure the control box power switch is in the OFF position.
STEP 8 Unscrew and remove the front cover of the control box and slide battery into position with its terminals to the left (see illustration). Make sure the battery fits snugly in control box.
OFF
Connect the black battery lead to the negative (–) terminal, and the red battery lead to the positive (+) terminal. DO NOT allow battery leads to touch the control board! Touching the control board with battery leads can short circuit the system!
RED WIRE to positive (+)
BLACK WIRE to negative (–)
Choose the electrical outlet into which the transformer will be plugged. Measure the distance from the electrical outlet to the control box, following the path where the low voltage wire will run (the maximum distance can be no more than 1000 ft.).
Predicting the exact maximum number of operational cycles at peak load is more of an art form than an exact science. The charts below illustrate the average maximum number of cycles (the “MNC”) in a 24 hour period on a typical single gate, and is installed such that the motor draws 10 amperes to move the gate.

Gate Capacity Chart for SL-2000 Series (estimated number of cycles based on use with a transformer)
Gate Capacity Chart for SL-1000 Series (estimated number of cycles based on use with a transformer)

INSTALLATION OF THE GTO TRANSFORMER CONT.
2) If the gate is binding or dragging, or if ball bearing rollers are not used, it will require more than 10 amps to move it. This will reduce the MNC. 3) The charts are based on the transformer being plugged into an outlet that provides a line voltage of 120 volts; if the outlet provides less than 120 volts (for example, some rural areas may only provide 105 volts), it can reduce the MNC by as much as 50%. 4) A fully charged standard battery has an inherent reserve of 20-50 cycles without requiring a charge. This allows peak loads at several points during the day, depending upon how much time the transformer has to provide a charge to the battery between cycles. The transformer is capable of fully recharging the battery in as little as five minutes at optimum conditions. 5) The charts on page 16 are based upon an ambient temperature of 40º F. Battery performance and speed at which it will recharge will fluctuate based upon temperature.
This table and map illustrates the maximum number of cycles per day to be expected in a particular area, using either one or two of GTO’s 10 watt solar panels (see Accessory Catalog). Figures are shown for winter (minimum sunlight) and do not account for use of any accessory items.
Estimated Maximum Number of Cycles Per Day
Winter Ratings Watts Zone 1 Zone 2 Zone 3
SL1000 10 4 8 13 SL1000 15 6 12 20 SL1000 20 8 16 26 Dual SL1000 15 3 6 10 Dual SL1000 20 4 8 13
Requires 24 Amp Hour Battery SL2000 10 4 8 13 SL2000 15 6 12 20 SL2000 20 8 16 26 Dual SL2000 15 3 6 10 Dual SL2000 20 4 8 13
Zone 2 Zone 3
Zone 3 Zone 3
Zone 1

STEP 9 Run the low voltage wire from the electrical outlet to the control box. Do not exceed 1000'.
INSTALLATION OF THE GTO TRANSFORMER CONT.
STEP 10: Strip 3/16" off the ends of the low voltage wire and attach ends to the transformer terminals; red wire to [RED], black wire to [BLK], (see Illustration I). A dab of household petroleum jelly on each terminal will help prevent corrosion.
We recommend crimping a spade-tongue terminal (not provided) to the end of each wire before attaching it to the transformer.
To prevent damage to transformer, make sure the exposed wire ends do not touch each other!
DO NOT plug the transformer into outlet. The transformer will be plugged in during STEP 13.

STEP 11: Feed the low voltage wires upward through the strain relief on the bottom of the control box (see Illustration J). Pull 6" to 8" of wire into the control box.
If accessories (i.e. safety loops, card readers, etc.) are to be added during this installation, do not tighten the strain relief screw against the wires until the accessories have been connected. When all accessories have been connected, fully tighten the strain relief screw against the wires.

INSTALLATION OF THE GTO TRANSFORMER CONT.
STEP 12: Strip 3/16" off the ends of the low voltage wire and twist tightly. These wire ends will be attached to the control board at the 18VAC terminals located on the POWER IN terminal block (see Illustration L). Wire sheathing should not come in contact with terminals, however, it should not be stripped so far that wires can come in contact with one another (see Illustration K).

Insert one transformer wire into an 18VAC terminal. Insert the other transformer wire into the remaining 18VAC terminal (see illustration L). Transformer wires can be connected to the 18VAC terminals regardless of color.
Tighten set screws against exposed end of wires (see Illustration K). A dab of household petroleum jelly on each wire end will help prevent corrosion.
The ACCESSORY terminal block provides the connection point for safety loops, wands, push buttons, intercoms, card readers, etc. See page 27 for more information about connecting accessories.

STEP 13: Plug the transformer into the electrical outlet. Check to see if the green LED on the control board is on. If it is not, see the Troubleshooting Guide on page 30.

The four DIP switches on the control board match the operator with the type of gate on which it is mounted. For example, gates may open right to left or left to right. Prior to packaging, the GTO/PRO SL-1000 and SL- 2000 series control board was configured for a single slide gate that opens right to left. If your gate type matches this configuration, you DO NOT need to adjust the DIP switches. Proceed to the Potentiometers section on the next page. NOTE: The direction a gate opens is determined by standing inside the property and facing toward the gate.

PULL/PUSH: Set to PULL for slide gates that open RIGHT to LEFT [factory setting]; PUSH for slide gates that open LEFT to RIGHT. SNGL/DUAL: Set to SNGL for a single gate leaf [factory setting]; DUAL for dual gate leaves. SEQ1: Controls the opening order of dual gate leaves. See Setting the Control Board for Dual Gate Operator Installation on page 37 for more information. (the factory setting is OFF). SEQ2: Controls the opening order of dual gate leaves. See Setting the Control Board for Dual Gate Operator Installation on page 37 for more information (the factory setting is OFF).


The three (3) potentiometers on the control board operate like a volume control on a radio. They control the auto close timer, inertia, and obstruction sensitivity of the operator. Use a small slotted screwdriver to turn the arrow in the center of the potentiometer. Clockwise rotation increases the setting (MAX). Counterclockwise rotation decreases the setting (MIN).
AUTO CLOSE (auto close timer): Determines how long the gate will remain open before it automatically closes. The limits are OFF to 120 seconds. The factory setting is OFF.
OFF 120
INERTIA: Fine tunes obstruction sensitivity in the opening and closing modes. INERTIA allows the operator to attempt to push an obstruction clear of the gate path. When INERTIA is set to MIN the operator will obstruct quickly (i.e, will attempt to push an obstruction briefly); when set to MAX the operator will obstruct slowly (i.e., will push against an obstruct for a longer period). The factory setting is MIN.
MIN
MAX
OBSTRUCT SENS.
1 2 3 4
OBSTRUCT SENS. (obstruction sensitivity): Determines the amount of force exerted by the gate on an obstruction before the operator stops and reverses. The gate will exert minimum force before obstructing when set to MIN. When set to MAX, the operator will exert maximum gate force before obstructing (i.e., the operator will require greater resistance before stopping and revers- ing.). The factory setting is MIN.
R B G
RCVR
READ WARNING BELOW!
ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR SERVICING YOUR AUTOMATIC GATE OPERATOR!
All three potentiometers were set to minimum at the factory. The OBSTRUCT SENS. potentiometer MUST be adjusted above the factory setting for your GTO/PRO SL-1000 or SL- 2000 operator to function properly. If the potentiometer is left at MIN, your gate operator may "obstruct" (i.e., stop and reverse) as soon as it is activated.
BE SURE TO PROPERLY RETEST THE GATE OPERATOR AFTER MAKING ANY ADJUSTMENTS; FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH.

All GTO transmitters are set to a standard code at the factory and are ready to activate the automatic gate operator. For safety and security, however, we strongly recommend that the factory setting be replaced with a personal code. Follow the directions below:


A. Turn control box power switch OFF. B. Unscrew and remove the control box cover. C. Press and hold the LEARN button on the control board, and turn the power switch ON. Release LEARN button. Wait 15 seconds for the receiver to charge. D. Press and hold transmitter button until the red STATUS LED comes ON. E. Release transmitter button. The new code is stored in the control board memory.
Replace the control box cover and turn the power switch to the ON position.


Use the transmitter to check the range of the receiver before permanently mounting it.
Consider the following when mounting the receiver:

FCC Regulation This device complies with FCC rules Part 15. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept an interference that may cause undesired operation.
Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.

After the operator is installed, adjust the open and closed position limit switches as needed. The limit switches determine how far the gate travels to open and to close.
Adjust the limit switches using the limit nuts. Lift limit switch plate to adjust limit nuts (see Illustration M).
The open and closed position switches will be reversed depending on whether the gate opens from left to right or from right to left (see Illustration N).
Limit Nut B Limit Nut A
If your gate opens from Right to Left:
Limit Nut A Open position stop – if gate opens right to left. Closed position stop – if gate opens left to right.
Limit Nut B Closed position stop – if gate opens right to left. Open position stop – if gate opens left to right.
However, if your gate opens from Left to Right:
Once the limit switches are adjusted, make sure the limit switch plate rests in the grooves on both limit nuts.

The GTO/PRO SL-1000 and SL-2000 series operators are equipped with built-in obstruction sensitivity. These operators are designed to stop and reverse the gate for 2 seconds when it comes in contact with an obstruction. However, obstruction sensitivity, even when properly adjusted, may not be sensitive enough to prevent bodily injury. For this reason, safety edges or photoelectric sensors MUST be installed on the gate. Safety edges (or photoelectric sensors) must be mounted in compliance with Underwriters Laboratories’ safety standard for gate operators, UL 325. Review page 6 for information about mounting requirements for safety edges and photo- electric sensors.
Refer to the sensor manufacturer’s instructions for information about installing these devices on a vehicular gate.
Make sure the control box power switch is OFF before connecting safety device wiring to the terminal blocks.
Insert the safety device wires into the CLS EDG terminal (located on the FIRST OPERATOR terminal block) for the gate closing mode. Ground the safety device at the GRN terminal. Connect the safety device wires for the gate opening mode to the OPN EDG terminal in the same manner.
MAKE SURE TO GROUND THE SAFETY DEVICES AT THE GRN TERMINAL! THE CONTROL BOARD COULD BE DAMAGED IF THE SAFETY DEVICES ARE NOT GROUNDED!

SECOND OPERATOR FIRST OPERATOR POWER IN ALARM ACCESSORY RCVR

Although GTO strongly recommends the use of additional safety devices, we do not endorse any specific brand names. Only use products that are certified and listed to be in compliance with UL (United Laboratories) and national and regional safety codes.
Call GTO Sales at 1-800-543-4283 for information on compatible products for your specific application.

Make sure the control box power switch is OFF before connecting accessories.
The ACCESSORY terminal block is the connection point for accessories such as push buttons, safety loops, intercoms, etc. The ACCESSORY terminal marked GRN (green) is the common ground for all accessories. GRN is paired with the terminals shown below when connecting accessories to the control board.

WHT (WHITE) USED WITH GRN (GREEN): This is the most frequently used pairing for a doorbell button, keypad, or keyswitch. Accepts input from or is used with N/O contact devices.
First contact will start the gate. Second contact will stop the gate. Third contact will reverse the gate.
Low Voltage Wire from Doorbell Button, Keypad, or Key Switch
BLU (BLUE) USED WITH GRN (GREEN): This pairing is typically used for a free exit or free entry devices. Accepts input from or is used with N/O contact devices
ON
GRN
ORG
WHT
BLU
R B G
First contact will open the gate.
Low Voltage Wire from Free Entry or
ORG (ORANGE) USED WITH GRN (GREEN): This pairing is frequently used for safety loops. Accepts input from or is used with N/O contact devices.
ON
This connection will not open your gate. The safety loop will activate only while the gate is in use. When using this combination, the gate will remain open or reopen if it is closing.
ORG
BLU
WHT
R B G
ALARM ACCESSORY RCVR
Low Voltage Wire from Safety Loops
Free Exit Devices

Mount the operator housing after all installation procedures are complete. Slide operator housing over legs, align holes, and use screws provided to attach housing to operator.


Review the safety precautions & operator warranty procedures contained in packet (attached to the operator housing) with the customer. Leave packet attached to the housing for future reference.

The GTO Slide Gate Operator is designed for minimum maintenance. However, for optimum performance and safety, the following maintenance procedures should be taken:
GATE Having a well maintained gate will ensure that the operator runs smoothly and safely. Make sure gate is hung level and plumb. Check and adjust periodically. Lubricate rollers periodically with grease appropriate for the coldest weather in your area.
SAFETY EDGES Periodically test the safety edges to make sure they are functioning correctly. If they are not, discard and replace immediately.
CONTROL DEVICES From time to time, check to ensure that all of the control devices connected to the operator are functioning. This is especially important for safety devices.
OPERATOR Occasionally inspect the chain to ensure that it is well lubricated, and oil the chain as necessary. Use CHAIN AND CABLE LUBE for best results. Check the gear sprockets and grease them as needed. Check the rollers and spray oil on them as needed.

Maintenance:
The operator has a 12 Vdc motor with mechanical limit switches.
The control board: This is a micro processor board. The power that runs the gate is from the battery and recharged,
through the board only, by a 18 volt 40 VA. (2.9 A) transformer.
There is one (1) green and one (1) red LED (light emitting diode) on the control board. They are for a quick reference only. All readings must be measured by a voltmeter!
The red light serves two purposes. The first is to aid in storing the personal transmitter code. See “Setting the Personal Transmitter Code”.
The second is to show the condition of the battery. If it is flashing, see the following section on “ Testing the battery.” The normal state of this light is on, but dim.
If the red LED is flashing it means that the system may have reached low voltage lockout; the unit does not have enough voltage to operate the system. One of the following problems may exist:
The green light serves as a quick visual indication that the control board is receiving power from the transformer.

The transformer: Two things can cause failure: the first is shorting the leads during the installation, or letting the
strands touch at the terminal on the control board. The second is a static charge (generally associated with a lightning storm or power outage); use of a surge protector will help.
Testing the battery: This is a 12 volt 7 Ah battery. The proper way to test this is to perform a load test. Place the
voltmeter on D.C.; put the red probe on the (+) positive terminal and place the black probe on (-) negative terminal. Then activate the unit and watch the voltmeter. The drop should not be more than 1 volt.
secure and corrosion free.
Remote control range: This will vary at each installation. (see FCC disclaimer on page 23), but generally varies
from 50 ft. to 100 ft.
Motor: 12 Vdc 90 rpm with case hardened gears. The motor current range is 2.5 to 10 A if the gate is in good working order.
Receiver: 5 Vdc / digital communication. ONLY GTO receivers can be connected to these terminals.
Control board: Microprocessor driven. Powered by 12 Vdc.
Monday – Thursday 7:30 A.M. – 5:30 P.M. and Friday 8:00 A.M. - 12:00 P.M. (Eastern Time) TELEPHONE (800) 543-1236 OR (850) 575-4144

If the GTO gate operator system is not operating properly and you have not been able to solve the problem, please follow the steps below:
1. Check the Trouble Shooting Guide (page 29). 2. Call your installer. 3. If you still cannot solve the problem, call the GTO Service Department at (850) 575-4144. 4. If repair or replacement is necessary, you will be assigned a Return Goods Authorization Number (RGA). Write the RGA # in LARGE BOLD PRINT on the outside of the package. 5. Carefully pack the component(s) authorized for return and ship freight prepaid to GTO, Inc., 3121 Hartsfield Road, Tallahassee, Florida, USA 32303.
collect WILL NOT be accepted at the factory. A copy of the owner’s receipt with date of sale and installation must accompany warranty related request for service.
Limited Two Year Warranty
GTO/PRO DC powered gate operators are warranted by the manufacturer against defects in materials and manufacturer workmanship for a period of two (2) years from date of purchase, provided recommended installation procedures have been followed.
In the case of product failure due to defective material or manufacturer workmanship within the two (2) year warranty period, the operator will be repaired or replaced (at the manufacturer's option) at no charge to the customer, if returned freight prepaid to GTO, Inc., 3121 Hartsfield Road, Tallahassee, Florida 32303. IMPORTANT: Call (850)575-4144 or fax (850) 575-8950 for a Return Goods Authorization (RGA) number before returning to factory. Products received at the factory without an RGA number will not be accepted. Replacement or repaired parts are covered by this warranty for the remainder of the two (2) year warranty period or six (6) months, whichever is greater. GTO will pay the shipping costs (equal to United Parcel Service ground rate) for return to the owner of items repaired under warranty.
The manufacturer will not be responsible for any charges or damages incurred in the removal of the defective parts for repair, or for the reinstallation of those parts after repair. This warranty shall be considered void if damage to the product(s) was due to improper installation or use, tampering, connection to an improper power source, or if damage was caused by lightning, wind, fire, flood, insects or other natural agent. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. This warranty is in lieu of all other warranties, expressed or implied. NOTE: Verification of the warranty period requires copies of receipts or other proof of purchase. Please retain these records.
After the two (2) years warranty period, GTO or one of its authorized service centers will make any necessary repairs for a nominal fee. Call GTO at (850) 575-4144 for more information.
®

A DUAL SLIDE GATE SYSTEM
the SL-2000 for dual slide gate systems.
AUTOMATIC GATE OPERATORS

Install the second gate operator in the same manner as the Single gate operator starting on page 14 of this manual. The second gate preparation and wiring of the second (auxiliary) operator follow on the next two pages. Once the second gate operator is installed, Set the DIP switches for DUAL gates and the order in which the gates open (“sequencing”). Setting the Control Board for Dual Gate Installations begins on page 37. SECOND GATE (AUXILIARY) OPERATOR PARTS & HARDWARE

(2) 2” square x 48” long legs
The SL-2200 comes with a battery and control box the SL-1200 does not.

(4) 1/4”-20 x 1/2” Screws
(4) 3/8”-16 x 2” diameter U-Bolts and (8) 3/8” Serrated Nuts (RB210)
(4) 3/8” -16 x 3” Carriage Bolts (RB659)

Install PVC conduit (not included) needed for power cables and low voltage wiring – see illustration below. The PRO SL-1200 and SL-2200 power cable and safety edge (required) wiring should be run through PVC conduit underneath the driveway. If you cut the driveway be sure to reseal it after all wiring is installed.

Run up to 1000' of low voltage wire to control box from transformer (wire not included).
PVC Conduit for power cable.

(Auxiliary Unit)


When the units are set in place and you have completed wiring the first unit follow the instructions below.


Step 1a: Run the battery jumper wire through the PVC from the battery in the Second Operator to the battery in the First Operator. Use the side strain reliefs on the control boxes to run battery jumper wire into control boxes. Using spade connectors, connect positive to positive and negative to negative.
SECOND OPERATOR FIRST OPERATOR POWER IN ALARM ACCESSORY RCVR
Power Cable from First Operator
Power Cable from Second Operator

Limit Nut A Open position stop – if gate opens right to left. Closed position stop – if gate opens left to right.
Limit Nut B Closed position stop – if gate opens right to left. Open position stop – if gate opens left to right.

SETTING THE CONTROL BOARD FOR DUAL GATE INSTALLATIONS
The Control Board DIP switches must be set to accommodate your particular type of installation. Since the SNGL / DUAL, SEQ1, and SEQ2 DIP switches are used by dual gate operator systems, they will be discussed in the following steps.
STEP 4: Make sure the control box power switch is OFF.
OBSTRUCT SENS.
STEP 5: Unscrew and remove the control box cover. Use a small screwdriver to move the SNGL / DUAL DIP switch to DUAL (see illustration).
MIN MAX
SEQ2
LEARN
The order of gate operation ("sequencing") must now be determined for your dual gate operators to function properly.
Refer to the illustrations on the next page.
BOTH OPERATORS OPEN SIMULTANEOUSLY BOTH OPERATORS CLOSE SIMULTANEOUSLY
OBSTRUCT SENS.
PULL/PUSH
MIN MAX
If SEQ1 is set to ON, and SEQ2 is set to OFF, the FIRST OPERATOR and SECOND OPERATOR open simultaneously, and the FIRST OPERATOR and SECOND OPERATOR close simultaneously (see illustration).
LEARN
·

OBSTRUCT SENS.
PULL/PUSH
MIN MAX
If SEQ1 is set to OFF, and SEQ2 is set to ON, the FIRST OPERATOR will open first, and the SECOND OPERATOR will close first (see illustration).
LEARN
OBSTRUCT SENS.
PULL/PUSH
SEQ1 SNGL/DUAL
MIN MAX
SEQ2
LEARN
If SEQ1 is set to ON, and SEQ2 is set to ON, The FIRST OPERATOR opens and closes first.
OBSTRUCT SENS.
PULL/PUSH
MIN MAX
If both SEQ1 and SEQ2 are set to OFF, the FIRST OPERATOR and SECOND OPERATOR will open simultaneously. The SECOND OPERATOR will close first.
LEARN
· ·

GTO Digital Keypad (F300) The weatherproof digital keypad can be easily installed as a wired or wireless keypad for all GTO swing and slide gate operators, and as a wired keypad for the Bulldog Pedestrian Gate Lock. It can be programmed to recognize fifteen different personal identification number (PIN) codes. Each code is face programmable with additional security features built in. Requires 3 AA batteries (not included). Can also accommodate most garage doors and other gate openers. If used as a wired keypad, 16 gauge standard, low voltage direct burial wire will be required (see RB509).
Garage Door Receiver (RB709) Allows the use of the same GTO remote transmitter (see Dual and Triple Transmitters) to control the gate operator and garage door opener. Compatible with most garage door openers.
GTO Entry Transmitter (RB741) The GTO Entry Transmitter, with adjustable code settings, is standard equipment with all GTO gate operator systems. Battery included.
GTO Key Chain Mini Transmitter (RB744) This miniature version of the GTO entry transmitter has the same adjustable code settings. Battery included.
GTO Dual Transmitter (RB742) GTO Triple Transmitter (RB743) The two and three button transmitters are used for the remote control of two or three gate operators and garage door openers (See Garage Door Receiver). Battery included.
Push Button (Doorbell) Control (RB101) Unlighted doorbell button for remote entry or exit control. Connects directly to the control board using 16 gauge stranded, low voltage, direct burial wire (not included, see RB 509).
GTO Bulldog Pedestrian Gate Lock (FM500) Similar to the Automatic Gate Lock but designed for horizontal use only on "walk-through" gates without automatic operators. The Bulldog is an affordable solution to protecting swimming pool areas, playgrounds, tennis courts, boat docks, etc., from unwanted access. Includes control box and keyed manual release. Can be used with the GTO Digital Keypad (F300).
, Inc.
GTO NEMA Box (FM317) GTO's NEMA 4X rated weatherproof box is large enough (14" W x 6" D x 16" H) to accommodate all add-on items necessary for custom gate operator installations. It is made of fire retardant ABS plastic and comes with a heavy duty 14 gauge steel backing plate for mounting accessories. The unique, lockable cover (use the Master® Pin lock RB975 for added security) can be completely removed for easier access during installation and service.
The NEMA box is standard on all GTO/PRO AC powered operators.
®

Pin Lock (RB975) The pin lock can be inserted in the chain brackets of the GTO/PRO SL-1000/1200 and SL-2000/2200 to prevent unauthorized removal of the quick release pins.
GTO Low Voltage Wire (RB509) The 16 gauge dual conductor, multi-stranded, direct burial low voltage wire is required to connect the control board to the solar panel or the AC transformer. This wire is also required for installation of some accessories such as keypads, locks, or push buttons (available in 1000' rolls and specially cut lengths).
#41 Slide Gate Chain (RB207) The #41 chain (32' only) is used with the GTO/PRO SL-1000/1200 and SL-2000/22000 DC Slide Gate Operators.
Splice Kit - Above Ground (RB707) For providing secure and moisture resistant above ground splices for solar panels, key pads, push buttons and other accessories using GTO low voltage wire.
Splice Kit - Direct Burial (RB708) When direct burial wire running below ground needs to be spliced the RB708 splice kit must be used.

Operator Solar Panel (FM123 ) - Improved, Amorphous Silicon (Two Year Warranty*) This 10 watt solar panel is a battery charger for use with GTO/PRO Low Voltage Automatic Gate Operator systems. Particularly suited for remote installations, the solar panel comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (for longer lengths, see RB509). All GTO low voltage operators are pre-wired for solar panels. Installation in some regions of the world will require multiple panels for adequate charging power. Recommended for GTO/PRO SL-2000/2200, GTO/PRO SL-1000/1200. NOTE: GTO/PRO SL-2000 requires the 24 Amp Hour Battery Kit for solar applications.
Operator Solar Panel (FM122 ) - Improved Amorphous Silicon (Two Year Warranty*) The 5 watt solar panel is a battery charger for use with GTO/PRO Low Voltage Automatic Gate Operator systems. Particularly suited for remote installations, the solar panel comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (see Low Voltage Wire for longer wire). All GTO low volatge operators are pre-wired for solar panels. Installation in some regions of the world will require multiple panels for adequate charging power. Recommended for GTO/PRO SL-1000, GTO/PRO SL-2000 and the GTO Bulldog Gate Lock. Dual gate installations require minimum of two (2) 5 watt solar panels for adequate charging power.

Standard Replacement Transformer (RB570) –Standard 18 volt AC transformer for GTO/PRO SL-1000 and SL-2000 series gate operators . Bulldog Replacement Charger (RB422) – Standard 12 volt DC charger for maintaining battery included with the Bulldog Pedestrian Gate Lock.
Replacement Batteries RB500 – The standard 12 volt, 7.0 ampere-hour, maintenance-free battery for all GTO/PRO gate operators. This is the only battery approved for use with GTO gate operators. Battery life 3 to 5 years.
RB422 –The 12 volt, 1.2 ampere-hour version for use with the Bulldog Pedestrian Gate Lock.
GTO/PRO 24 Amp Hour Battery Kit FB295 – This large 12 volt, 24 ampere-hour, maintenance-free battery is for the GTO/PRO SL-2000&2200 gate operators. It will supply additional power for increasing the number of open and close cycles of the GTO/PRO SL-2000&2200 operators. The kit comes with the battery, battery pan and wiring harness for easy installation inside the existing operator housing. This is the only battery approved for use with GTO gate operators. Battery life 3 to 5 years.
Replacement Receivers The AQ202: Receiver with a 20 ft. cable (included). The AWQ325: Receiver with a 25 ft. cable. The AWQ350: Receiver with a 50 ft. cable. The AWQ400: Receiver with a 100 ft. cable.
Standard Replacement Power Cables for Gate Operators The PRO 60C (AC202): 60 ft. power cable included with GTO SL-1200 and SL-2200 dual (second) slide gate operator.
GTO EXIT WAND (FM138) The GTO Exit Wand is designed for residential and agricultural applications and is compatible with all the GTO/PRO automatic gate opener models. The Exit Wand is an electromagnetic sensor, which offers 'hands free' operation of automatic gate openers with a 12 ft. radius of detection of vehicles in motion.

* GTO, Inc. gate operator accessories are warranted by the manufacturer against defects in materials and workmanship for a period of one year, unless otherwise stated, from the date of purchase provided recommended installation procedures have been followed. Warranty is considered void if damage was due to improper installation or use, connection to an improper power source, or was caused by lightning, wind, fire, flood, insects, or other natural agent.

The installation of this operator conforms to CLASS
The installer verifies that (each item must be checked):
___ Required safety edges were installed.
___ Roller guards were installed over gate rollers.
___ Fence was screened so that no one can reach through the gate to operate controls.
___ Customer was informed that this gate is for vehicular use ONLY. Pedestrians MAY NOT use this gate.
___ A separate gate or entrance was installed for pedestrian use.
___ All warning signs and labels were installed as specified in the IMPORTANT SAFETY INSTRUCTIONS.
___ Safety instructions were reviewed with the customer.
___ The IMPORTANT SAFETY INSTRUCTIONS manual was given to the customer.
___ Customer was instructed about proper use of the foot pedal release.
___ Customer was instructed about proper use of transmitter and (or) other entry controls.
___ Customer was asked to fill out customer support card and mail it to GTO, Inc.
___ Customer was asked to retain all receipts (receipts provide proof of warranty).
___ Customer was asked to retain IMPORTANT SAFETY INSTRUCTIONS, etc. for future reference.
___ The completed installation was photographed from both the front and back of the gate. Photo was dated.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.