UL325 SERIES 352 ® E-Z GATE OPENER
WARNING!
This equipment is similar to other gate or door equipment and meets or exceeds Underwriters Laboratory Standard 325 (UL 325). However, gate equipment has hazards associated with its use and therefore by installing this product the installer and user accept full responsibility for following and noting the installation and safety instructions. Failure to follow installation and safety instructions can result in hazards developing due to improper assembly. You agree to properly install this product and that if you fail to do so GTO, Inc. shall in no event be liable for direct, indirect, incidental, special or consequential damages or loss of profits whether based in contract tort or any other legal theory during the course of the warranty or at any time thereafter. The installer and/or user agree to assume responsibility for all liability and use of this product releasing GTO, Inc. from any and all liability. If you are not in agreement with this disclaimer or do not feel capable of properly following all installation and safety instructions you may return this product for full replacement value.
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate opener. This gate opener produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times.
All automatic gate openers are intended for use on vehicular gates only.
This product meets and exceeds the requirements of UL 325, the standard which regulates gate opener safety,
as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
For more information on Mighty Mule’s full line of Automatic Gate Openers and Access Controls visit our website at www.mightymule.com
GTO Technical Service (800) 543-1236 or (850) 575-4144 For 24 hr/day, 7 day/week Technical Service visit http://support.gtoinc.com/support/troubleshooter.aspx
©2008 GTO, Inc.
rev - 08/08/08

The Mighty Mule® Gate Opener is intended for use with vehicular swing gates. The opener can be used in Class I, Class II and Class III applications.
Vehicular gate opener class categories
Residential Vehicular Gate Opener-Class I: A vehicular gate opener (or system) intended for use in a home of one-to-four single family dwelling, or a garage or parking area associated therewith.
Commercial/General Access Vehicular Gate Opener-Class II: A vehicular gate opener (or system) intended for use in a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail store, or other building servicing the general public.
Industrial/Limited Access Vehicular Gate Opener–Class III: A vehicular gate opener (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public.
Converting Metric Units to English Equivalents When You Know Multiply By To Find Symbol
centimeters 0.3937 inches in. (or ") meters 3.2808 feet ft. (or ') kilograms 2.2046 pounds lb. (or #)
Converting English Units to Metric Equivalents When You Know Multiply By To Find Symbol
inches 2.5400 centimeters cm feet 0.3048 meters m pounds 0.4535 kilograms kg
Converting Temperature deg. Celsius (ºC x 1.8) + 32 deg. Fahrenheit ºF deg. Fahrenheit (ºF-32) ÷ 1.8 deg. Celsius ºC
Please record the product serial number (located on the rear of opener arm), and the date and place of purchase in the spaces provided below. Refer to this information when calling GTO for service or assistance with your automatic gate opener.
Serial Number Date of Purchase
Remember to keep all receipts for proof of purchase.



PLEASE READ THIS FIRST!
Thank you for purchasing a Mighty Mule® 352 E-Z Gate Opener—GTO's "do-it-yourself" automatic gate opener! When correctly installed and properly used, your Mighty Mule® 352 E-Z Gate Opener will give you many years of reliable service. Please read the following information and watch the enclosed video to ensure you have the correct system for your particular needs. Furthermore, this manual and the video will enable you to properly install your Mighty Mule® 352 E-Z Gate Opener.
The Mighty Mule® 352 E-Z Gate Opener is designed for installation on a pull-to-open dual gate leafs (gates that open into the property). By purchasing an accessory bracket (FM148), the Mighty Mule® 352 E-Z Gate Opener can accommodate a push-to-open dual gate leafs (gates that open out from the property). The gates must not exceed 8 feet and 550 pounds or exceed 16 feet and 150 pounds (please see Technical Specifications on page 10). The Mighty Mule® 352 EZ Gate Opener can be used on vinyl, aluminum, chain link, farm tube, and wrought iron gates.
Use on solid (surface) gates is not recommended. Solid surface gates have a high resistance to the wind. If the wind is strong enough, the opener will obstruct and stop, blow fuses, or may damage the equipment.
The Mighty Mule® 352 E-Z Gate Opener accommodates extra transmitters, digital keypads, solar panels, push buttons, automatic gate locks, and other access control products. These optional accessories (see the enclosed Mighty Mule® Accessory Catalog) are available at most stores. Your store should be able to special order any accessory not in stock. If your store cannot special order accessories, please call the GTO Sales Department (800-543-GATE).
The Mighty Mule® 352 E-Z Gate Opener features adjustable obstruction sensing. This safety feature makes the gate stop and reverse direction within 2 seconds when it comes in contact with an obstruction. MIN is the factory setting; meaning the gate will exert the minimum force on an obstruction before it stops and reverses direction.
The Mighty Mule® 352 E-Z Gate Opener also has an adjustable auto-close feature. After the gate reaches the fully open position, it can be set to remain open up to 120 seconds before automatically closing. Pressing the transmitter button at any time after the gate opens fully will cause it to close immediately. OFF is the factory setting; meaning the gate will stay open until you press the transmitter (or keypad, etc.) again.
PLEASE NOTE—If your application requires any of the following: Slide gates; Heavy duty or commercial uses; Professional installation;
please call GTO at (800) 543-GATE [4283] or (850) 575-0176 for information about our GTO/PRO professional line of gate openers and accessories. Our Sales Department will be glad to give you the name and phone number of a GTO/PRO dealer near you.
BEFORE YOU BEGIN TO INSTALL YOUR AUTOMATIC GATE OPENER: watch the enclosed video and read these instructions carefully and completely to become familiar with all parts and installation steps. The video is only designed
as an overview of the installation procedure. You must read the installation manual
for detailed instructions on gate opener safety and proper use of the gate opener.

Because automatic gate openers produce high levels of force, consumers need to know the potential hazards associated with improperly designed, installed, and maintained automated gate opener systems. Keep in mind that the gate opener is just one component of the total gate operating system. Each component must work in unison to provide the consumer with convenience, security, and safety.
This manual contains various safety precautions and warnings for the consumer. Because there are many possible applications of the gate opener, the safety precautions and warnings contained in this manual cannot be completely exhaustive in nature. They do, however, provide an overview of the safe design, installation, and use of this product. CAREFULLY READ AND FOLLOW ALL SAFETY PRECAUTIONS, WARNINGS, AND INSTALLATION INSTRUCTIONS TO ENSURE THE SAFE SYSTEM DESIGN, INSTALLATION, AND USE OF THIS PRODUCT.
Precautions and warnings in this manual are identified with this warning symbol. The symbol identifies conditions that can result in damage to the opener or its components, serious injury, or death.
Because GTO automatic gate openers are only part of the total gate operating system, it is the responsibility of the consumer to ensure that the total system is safe for its intended use.
Disconnecting the Opener 1. Turn opener power switch OFF. 2. Remove hairpin clip, clevis pin, and bushing from the front mounting point. 3. Remove the opener from the mount. The gate can be opened and closed manually when the opener is disconnected.
0caVW\U CAUTION: Because the Mighty Mule gate opener is battery powered, disconnect the opener ONLY when the power switch on the opener is turned OFF. Unplugging the transformer does not turn power to the opener OFF.

For The Consumer WARNING: To reduce the risk of injury or death:
I. Before Installation
ZONE 5
ZONE 3
ZONE 3
ZONE 4
ZONE 4
Entrapment Zones for a Pull-To-Open Application
Gate in the Open Position Gate in the Open Position
Driveway

Entrapment Zones for a proper Pull-To-Open installation: Zone 1 – leading edge of the master and second gate. Zone 2 – between the gate and the gate post. Zone 3 – the path of the gate. Zone 4 – the space between the gate in the open position and any object such as a wall, fence, tree, etc. Zone 5 – pinch points between the opener and gate.
II. During Installation
10' 10'
10' 10'
NEVER INSTALL any control device
10' 10'
within gray area

III. After Installation
Additional copies of this manual can be obtained by downloading one from the Mighty Mule® web site (www.mightymule.com), by contacting GTO, Inc., at 3121 Hartsfield Road, Tallahassee, Florida 32303 or by calling 1-800-543-4283 and requesting a duplicate copy. One will be provided to you free of charge.

Secondary Means of Protection Against Entrapment
As specified by Gate Opener Safety Standard, UL 325 (30A.1.1), automatic gate openers shall have an inherent entrapment sensing system, and shall have provisions for, or be supplied with, at least one independent secondary means to protect against entrapment. The Mighty Mule® 352 utilizes Type A, an inherent (i.e., built-in) entrapment sensing system as the primary type of entrapment protection. Also, the Mighty Mule® has provisions for the connection of Type B2 protection to be used as the secondary type of entrapment protection.
A. One or more contact sensors shall be located at the leading edge, bottom edge, and post edge,
both inside and outside of a vehicular swing gate system. B. A hard wired contact sensor shall be located and its wiring arranged so that the communication
between the sensor and the gate opener is not subjected to mechanical damage. C. A wireless contact sensor such as one that transmits radio frequency (RF) signals to the gate opener for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures, natural landscaping or similar obstruction. A wireless contact sensor shall function under the intended end-use conditions.

on both sides of the gate Post Edge Contact Sensor
ENTRAPMENT ALARM (UL 325; 30A.1.1A) The Mighty Mule® 352 Gate Opener is designed to stop and reverse within 2 seconds when the gate comes in contact with an obstruction. Additionally, these openers are equipped with an audio entrapment alarm which will activate if the unit obstructs twice while opening or closing. This alarm will sound for a period of 5 minutes, or until the opener receives an intended signal from a hardwired entry/exit source (e.g. push button control or keypad) and the gate returns to a fully open or fully closed position. Turning the power switch on the control box OFF and back ON will also deactivate the alarm. Wireless controls such as transmitters and wireless keypads will not deactivate the alarm.

Required Safety Precautions for Gates
Gate Lock (recommended, not included)
Contact Sensor (recommended, not included)

(recommended, not included) Contact Sensor
(recommended, not included)
(recommended, not included)
Entrapment Protection GTO’s inherent obstruction settings, even when properly adjusted, may not be sensitive enough to prevent bodily injury in some circumstances. For this reason, safety devices such as safety edge sensors (or photoelectric sensors), which stop and reverse gate direction upon sensing an obstruction, are suggested for enhanced protection against entrapment.

Bulldog Pedestrian · Contact Sensor · Contact Sensor

These warning labels should be found at the locations specified below. If any of them are missing, immediately contact GTO for replacements.
GTO DC SWING Series Conforms to UL325 5th Edition Standards
Serial No. MM350DUAL-0000000
GTO, Inc. - Tallahassee, Florida USA
This label is located under rear mount on the opener.
TO MANUALLY OPEN AND CLOSE THE GATE 1. Turn opener power switch OFF. 2. Disconnect front or rear mount from mounting bracket. 3. Pull opener away from mounting bracket and move gate. Disconnect opener ONLY when the power switch is OFF and the gate is not moving.
1-800-543-GATE (4283) • www.mightymule.com
Can Cause Injury or Death MOVING GATE!
Logo and warning labels (2) installed on each side of opener housing.
Product identification label · 05/14/08




YOU MAY ALSO NEED THESE ITEMS BEFORE YOU BEGIN THE INSTALLATION (Some of these items can be found in the Accessory Catalog page 42):

OPERATIONAL CAPACITY • The Gate Capacity Chart shows approximate cycles, per day, you can expect from the Mighty Mule 352 Au- tomatic Gate Opener when powered with a transformer. Actual cycles may vary slightly depending upon the type and condition of gate and installation.
Mighty Mule 352 Gate Capacity /Cycle Chart Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery.
Number of Cycles Per Day
550 lbs. 450 lbs. 350 lbs. 250 lbs. 150 lbs. 100 lbs. 50 lbs.
62 67 72 77 82 87 92 5’ - 6’
57 62 67 72 77 82 87 8’
NR NR NR
NR NR NR NR
57 62 67 72 77 82 10’
57 62 67 72 77 12’
57 62 67 72 14’
57 62 67 16’
* These specifications are subject to change without notice.
listed on page 22 or call (800) 543-1236 or (850) 575-4144 for more information. * An operation cycle is one full opening and closing of the gate.
Gate Weight · Gate Length

The diagram shown below is an example of a pull-to-open installation on a chain link fence and dual gate. Mounting the openers on masonry columns requires special procedures; see Column Installation Information on page 42 if you intend to mount the openers on columns. Furthermore, if you have push- to-open gates, you will need to purchase 2 push-to-open brackets (FM148) (see Accessory Catalog) to properly configure your system. See push-to-open installation on page 36 before proceeding.

Gate Swings Evenly and Freely Hung Firmly and Plumb Receiver
Run 1000' (max.) of low voltage wire to battery from transformer (wire not included).
You will need to trench across the driveway in order to lay conduit for the second battery harness and communication cable.
32 foot communication cable allows the MASTER and SECOND gate openers to operate as an integrated dual gate system. (run in PVC conduit)
PVC conduit (not included) to protect wire from lawn mowers and weed eaters.
32 foot power cable connects SLAVE to 12 Volt marine or automotive type battery. (run in PVC conduit)
Step 1 The gate must be plumb, level, and swing freely on its hinges. Wheels must not be attached to the gate. The gate must move throughout its arc without binding or dragging on the ground. Note that gates over 250 lb. should have ball bearing hinges with grease fittings.

Step 2 The fence post must be secured in the ground with concrete so it will minimize twist or flex when the opener is activated. We recommend you position the opener near the centerline of the gate to keep the gate from twisting and flexing and to avoid backsplash from rainwater. The addition of a horizontal or vertical cross member (if one is not already in place) to provide a stable area for mounting the gate bracket is also important.

The position of the post bracket determines the leverage and efficiency of the opener. The post bracket position also sets the clearance between the opener and gate in the open and closed positions (minimum 2 inches for safety reasons).
The curved design of the post bracket works well for installations on round and square fence posts. Because the post bracket carries the entire thrust of the active opener, bolts that completely penetrate the fence post must be used.
On wooden posts, place a metal plate or washer (not supplied) between the nuts and the fence post to prevent the thrust of the opener from pulling the bolts and washers out of the wood.

On round posts of 6" diameter or larger, the post pivot bracket may not be necessary for the installation. In this instance, the two post brackets are mounted by themselves.


Determining the Mounting Position of the Post Bracket Assembly and the Gate Bracket
Step 3 Insert the 3/8" x 2" bolt through the center hole of the post brackets and post pivot bracket as shown. Fasten a 3/8" washer, 3/8" lock washer and 3/8" nut on the end of the bolt. DO NOT overtighten the nut because the post pivot bracket will have to be adjusted later.


Step 4 Attach post bracket assembly and gate bracket to the opener with the clevis pins and bushings. Secure the clevis pins with hairpin clips.

Step 5 With the gate in the open position (up to 110º from its closed position), and the opener fully retracted, adjust the post bracket assembly and gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate.


IMPORTANT: While determining the mounting point for the post pivot bracket assembly, be sure that the position allows for minimum 2 inches of clearance between the gate and the opener in both the open and closed positions, as shown in the diagrams below. This clearance will give the opener the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area.
Step 6 After verifying that you have the best position for the post pivot bracket in the open position, insert the 5/16" x 1-3/4" bolt through the aligned holes of the post bracket and post pivot bracket to hold it in place. Remove the clevis pin from the front mount and while supporting the gate opener, swing the gate and gate opener to the closed position. With the gate and gate opener in the closed position check the clearance and be sure that the gate opener is not binding at the post pivot bracket.
If you don't have 2 inches of clearance or the gate opener is binding on the post pivot bracket, remove the 5/16" x 1-3/4" bolt and readjust the pivot bracket until you can achieve these important clearances.
With the post pivot bracket in the optimum position for clearance and freedom of movement, reattach the opener to the gate bracket in the open position and recheck the gate opener level and make sure the brackets are clamped securely.


Step 7 Mark reference points for bolt holes on the fence post through middle of bracket slots. Marking reference points in this manner allows room for adjustment when mounting the post bracket assembly and gate bracket. After marking your reference points, remove the opener and brackets from the fence and gate.
Mark fence post through middle of bracket slots and drill 3/8" holes

Step 8 Drill 3/8" holes into fence post as marked.
Step 9 Fasten post bracket assembly to the fence post using (4) 3/8" x 8" bolts, washers, lock washers, and nuts (provided). Remove excess bolt length extending beyond the tightened nuts with a hacksaw or bolt cutters.

Step 10 Mark reference points for bolt holes on the gate cross member through middle of gate bracket slots. Drill 3/8" holes into the gate cross member as marked.
Remove excess bolt length with hacksaw or bolt cutters

Mount gate bracket using (2) 3/8" x 3" bolts, washers, lock washers, and nuts (provided). Cut off excess bolt length extending beyond the tightened nuts.
Mark cross member through middle of gate bracket slots and drill 3/8" holes

Mounting Plate Created for Decorative Gate (required but not supplied)
Remove excess bolt length with hacksaw or bolt cutters
Round Metal Post · Square Metal Post · Round Wood Post

Mounting the Master Opener Step 11 Attach the opener to the securely bolted post bracket assembly and gate bracket using clevis pins, bushings, and hairpin clips, or optional Pin Locks (see Accessory Catalog). Verify that the opener is level and adjust the post bracket assembly if necessary.

Install the second opener on the remaining gate leaf by repeating Step 3 through Step 11, starting on page 13. After you have mounted the second opener, proceed to Installing the Positive Stops.

The Mighty Mule® 352 Gate Openers firmly hold the gates in the closed position using positive stops. The positive stops help stabilize the gate leaves in the closed position. To further enhance stability and security, we strongly recommended using an optional Mighty Mule® Automatic Gate Lock (see Accessory Catalog) with your dual gate.

Illustration A

Step 1 Attach the horizontal closed position stop plate to the MASTER gate leaf.
Detach the gate operators from the gates and move the gates to their closed position (Illustration A). Using appropriate hardware for your type of gate (U-bolts for tube or chain link; screw or bolts for wood or metal - not supplied) attach the closed position stop plate (horizontally) about mid height on the MASTER gate frame. Do not tighten it completely at this time. Slide the stop plate toward the frame of the SECOND gate leaf until they touch (Illustration B). Once you have moved the stop plate to the correct position, tighten its hardware completely.
B=>D73E
Closed Position Stop Plate mounted on the gate leaf that CLOSES FIRST
Step 2 Install a low profile ground stop (not provided) beneath the SECOND gate stop plate.
Closed Position Stop Plate Low Profile Ground Stop in Near the Center of Driveway
The ground stop needs to be positioned near the end of the gate as shown in Illustration A and may be made of metal or concrete and should be firmly secured in the ground (we recommend setting it in concrete).
Step 3 Attach a vertical closed position stop plate to the SECOND gate.
Using appropriate hardware for your type of gate attach the vertical closed position stop plate to the SECOND gate frame at the point where it will come in contact with the ground stop post. Do not tighten it completely at this time. You must slide the closed position stop plate toward the ground stop until they touch (Illustration C). Once you have moved the stop plate to the correct position, tighten its hardware completely.


At this stage of the installation, the openers should be installed on the gate leaves and the open and closed position stops should be in place.


Step 1 Trench and place 3/4 inch or larger PVC conduit from Master Opener Arm to Second Opener Arm. At this time you may also choose to trench and lay conduit from an AC power source to the gate for connecting the 18V transformer.
Step 2 Route the 32 foot second battery harness cable and 32 foot Communication Cable through the PVC conduit running from the Second Opener Arm to the Master Opener Arm.

32 foot Second Battery Harness Cable and 32 foot Communication Cable routed through the PVC conduit. 3/4 inch or larger PVC Conduit
Trench cut across driveway for routing of the Communication Cable and Second Battery Harness Cable.


In order to have easy access to the control boards during the rest of the installation, remove the master and second openers and remount them upside down.
ON/OFF Switch IMPORTANT: Return opener arms to the upright position when installation is complete to prevent water damage to the control board.


With the MASTER opener mounted in the upside down position remove the Control Board Access Panel on the bottom of the opener arm.
Place the 12 Volt automotive or marine type battery and its weatherproof case within 6 feet of the fence post where the master opener arm is mounted.
Connect the Communication Cable coming out of the conduit from the Second Opener to the LINK terminal on the master opener arm control board. Be sure to leave enough slack in the cable to accomodate routing of cable through access panel.
Run the end of the10 foot Master Battery Harness cable up to the Master Opener and plug it into the Battery Harness Connector located in the opener access panel. DO NOT connect the other end of the Battery Harness cable at this point.

Step 1
With the SECOND opener mounted in the upside down position remove the Control Board Access Panel on the bottom of the opener arm.

Connect the Communication Cable coming out of the conduit from the Master Opener to the LINK terminal on the second opener arm control board. Be sure to leave enough slack in the cable to accomodate routing of cable through access panel.
Run the end of the Second Battery Harness Cable up to the Second Opener and plug it into the battery harness terminal on the control board. DO NOT connect the other end of the Battery Harness cable at this point.

At this point your gate openers should be connected like the picture below.

and Gate Activity chart below.
– it will damage the control board –
Solar Panel and Gate Activity Chart
The table and map illustrate the maximum number of gate cycles to expect per day in a particular area when using from 10 to 30 watts of solar charging power. (see Accessory Catalog). The figures shown are for winter (minimum sunlight) and do not account for the use of any accessory items.
Winter Ratings Zone 1 Zone 2 Zone 3
12 v dual gate (10 watts) solar charger 4 8 13 12 v dual gate (15 watts) solar charger 7 13 20 12 v dual gate (20 watts) solar charger 10 18 27 12 v dual gate (25 watts) solar charger 13 23 34 12 v dual gate (30 watts) solar charger 16 28 41

Accessories connected to your system will draw additional power from the battery and will require additional solar panels.
* Use up to 250 feet of 16 AWG wire to place solar panel in a good location.

Attach the 10 foot battery harness wires provided, to the terminals of the battery. Take care to attach the BLACK wire to the NEGATIVE terminal and the RED wire to the POSITIVE terminal. Reverse connection will cause damage to the control board.

32 ft Second Opener Battery Harness Cable run through PVC

If you are using SOLAR PANEL(S) to charge the opener battery, skip this section and go to "Connecting Solar Panel(s)" section on page 26.
DO NOT use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire are inadequate for use with your gate opener system. Telephone wire and solid core wire do not deliver enough voltage for your gate opener to function and will cause the system to go into a condition known as "low voltage lockout."
NEVER splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to carry an adequate current.
Step 1 Select the 120 Volt electrical outlet into which you will plug the transformer. Lay the low voltage wire in a trench following a path from the selected electrical outlet to the control box. Wires coming up from the ground should be run through PVC conduit to protect them from lawn mowers, weed eaters, and grazing animals. Be sure to bury the wire laid in the trench.
Step 2 Bring enough wire up through the PVC conduit to allow for gate movement from open to closed position. See example right.

PVC conduit (not included) to protect wire from lawn mowers and weed eaters.
Run 1000' (max.) of low voltage wire to control board from transformer (wire not included).


Step 3 Strip 3/16" off the ends of the low voltage wire and twist tightly. Insert these ends to the 18 VAC terminal block located on the control board (see illustration at right). The wires can be inserted into either terminal regardless of color. Be certain not to let the exposed wires touch each other!
Tighten set screws against exposed end of wires. A dab of household petroleum jelly on each terminal will help prevent corrosion.
Step 4 At the AC outlet strip 1/2" of insulation from the ends of the low voltage wire. Attach these stripped ends to the transformer terminals.

A dab of household petroleum jelly on each terminal will help prevent corrosion.
Spade Tongue Terminal (not provided)
We suggest crimping a spade tongue terminal (not provided) to the end of each wire before attaching it to the transformer.
Make sure the exposed wires do not touch each other!

Step 5 Plug the transformer into the electrical outlet. (Use of a surge protector with the transformer is strongly recommended - not included) If electrical outlet is located outdoors, outlet and transformer should be protected by a weatherproof cover.

Connecting Solar Panel(s)
CHARGING POWER
RF
AUX OUT SOLAR PANEL
18VAC
EXIT
SAFETY
EDGE
CYCLE
COMMON
GRN
BLK
RED
RCVR
If you are using the transformer included with the Mighty Mule 352 to charge the opener battery, skip this section and go to "MASTER CONTROL BOARD SETTINGS" below.
Strip 3/16" off the ends of the low voltage wire from the solar panel and twist tightly. Attach the RED solar panel wire to the SOLAR terminal marked (+) and the BLACK solar panel wire to the SOLAR terminal marked (–) on the MASTER control board.
Low Voltage Wire from Solar Panel(s)
Solar Panels connect in PARALLEL
Tighten set screws against exposed end of wires. A dab of household petroleum jelly on each terminal will help prevent corrosion.
BLACK BLACK
attach BLACK to negative (–) solar terminal on control board attach RED to positive (+) solar terminal on control board
DIP Switches Main DIP Switch Settings (MODES)
SET LIMIT
LEARN REMOTE
ON
PULL-PUSH MODE1 MODE2 LOCK/BEACON
DIP Switch #1 - Push/Pull-to-Open If your gates open into the property the DIP Switch is set to OFF (factory default). If your gates open out from the property the DIP Switch must be set to the ON position. NOTE: if you have a Push-to-Open gate application you will need Push-to-Open brackets (see Push-to-Open Instructions on page 36).
PULL-PUSH MODE1 MODE2 LOCK/BEACON
RF
CHARGING POWER
MODE 1 MODE 2
LINK
DIP #2 DIP #3 Dual Mode Sequence
EXIT
SAFETY
EDGE
CYCLE
COMMON
GRN
BLK
RED
AUX OUT SOLAR PANEL
OFF OFF Single Gate Mode
ON OFF MASTER opens 1st, SECOND opens 2 seconds later. SECOND closes 1st, MASTER closes 4 seconds later. (factory)
OFF ON MASTER opens 1st, SECOND opens 2 seconds later. SECOND closes 1st, MASTER closes 8 seconds later.
ON ON MASTER and SECOND simultaneously open and close.
DIP Switch #4 - Lock/Beacon This DIP selects the mode of operation of the "AUX OUT" terminal. The OFF (factory) setting is selected when the Mighty Mule Automatic Gate Lock is used with the Mighty Mule 352. The RED wire from the lock is connected to the "AUX OUT +" terminal and the BLACK wire from the lock is connected to the "AUX OUT –" terminal. Factory default-(OFF position provides a timed pulse of voltage to the accessory while the gate opener is activated). Lock and circuit board will be damaged if #4 is on.
The ON setting is selected when a beacon or light is used with the Mighty Mule 352. One wire from the low voltage beacon or light is connected to the "AUX OUT +" terminal and the other to the "AUX OUT –" terminal. (ON position provides a continuous voltage to the accessory while the gate opener is activated). Important: Make sure your light or beacon is a 12Vdc system that draws less than 2 amps or less than 25 watts.

MIN MAX STALL FORCE
OFF 120
CLOSE TIME
The Stall Force potentiometer on the con- trol board operates like a volume control on a radio. It controls the obstruction sensitivity (or the amount of force the opener will apply to an obstruction) before it automatically stops and reverses direction for approximately two (2) seconds.
LEARN REMOTE
MIN MAX STALL FORCE
SET LIMI
ON
PULL-PUSH MODE1 MODE2 LOCK/BEACON
MIN MAX STALL FORCE
RF
Use a small slotted screwdriver to turn the arrow in the center of the potentiometer. Adjust the sensitivity from the MINIMUM position where the gate operates without obstructing from its own weight or the wind conditions in your area.
EDGE
CYCLE
COMMON
GRN
BLK
RED
RECR
ALWAYS KEEP SAFETY AT THE TOP OF YOUR LIST WHEN ADJUSTING OR

CLOSE TIME (auto close timer): Determines how long the gate will remain open before it automatically closes. The limits are OFF to 120 seconds. The factory setting is the OFF position.

Use the transmitter to check the range of the receiver before permanently mounting it.
Consider the following when mounting the receiver:
FCC Regulation This device complies with FCC rules Part 15. Operation is subject to the following conditions: 1. This device may not cause harmful interference. 2. This device must accept an interference that may cause undesired operation.
Transmitter distance may vary due to circumstances beyond our control. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.

* NOTE: You may need to set the stall force slightly off of minimum depending on the size and weight of the gate.
For PULL-TO-OPEN Installation
Turn the power switches on the opener arms to the ON position
Your Mighty Mule 352 has two Limit Settings
Step 1 While programming, be sure the gate is in the OPEN POSITION and the operator is mounted upside-down with “SET LIMIT" PROGRAM BUTTON visible on the control board. Step 2 Activate your opener by pressing the entry transmitter. Your gates should now be moving from the fully open position toward the closing position. Press the transmitter again to stop the gate at the desired closed position. Note: whichever gate reached its desired closed position first that will be the first one to be programmed.
SET LIMIT Button MASTER CONTROL BOARD
CLOSE TIME
SET LIMIT
LEARN REMOTE
ON
PULL-PUSH MODE1 MODE2 LOCK/BEACON
CHARGING POWER
RF
T SOLAR PANEL
18VAC
EXIT
SAFETY
EDGE
CYCLE
COMMON
GRN
BLK
RED
RECR
STATUS
SET LIMIT Button SECOND CONTROL BOARD
TESTING YOUR CLOSED LIMIT SETTING: Press your entry transmitter and allow your gate to close. If CLOSED position is not correct or needs to be changed you will need to CLEAR your CLOSED LIMIT (see below) setting and follow steps 1 through 3 again.
MIN MAX STALL FORCE
CLEARING PROGRAMMED CLOSED LIMIT SETTING: If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to its fully opened position, then press and hold the "SET LIMIT" button on the corresponding arm for 5 seconds. This will clear the memory for the closed limit position. Follow Steps 1-3 again.
Fully Open Position · Fully Closed Position

All GTO transmitters are set to a standard code at the factory and are ready to operate your Mighty Mule® 352 Gate Opener®. For your safety and security, however, we strongly recommend that you replace the factory setting with your own personal code. Follow the directions below:

On the back of the transmitter use a small phillips head screw driver to remove the two screws on the sides of the visor clip and separate the front cover from the transmitter. With the front cover removed, the battery and the DIP switches will be exposed. To set a new code, use a small screwdriver to move the switches.
1 2 3 4 5 6 7 8 9
There are nine (9) transmitter DIP switches; each can be placed in three different positions (+, 0, –). DO NOT set all the switches in the same position, such as all +, all 0, or all –. Once the DIP switches have been set to a personal code, replace and close the access cover.
1 2 3 4 5 6 7 8 9

A. Press and hold transmitter button. B. Press and hold the LEARN REMOTE button on the control board until it beeps. C. Release transmitter button. D. Release LEARN REMOTE button. The new code is stored in control board memory.

Although GTO strongly recommends the use of additional safety devices, we do not endorse any specific brand names. Only use products that are certified and listed to be in compliance with any
applicable UL standards (Underwriters Laboratories) and national and regional safety codes.
products for your specific application.

1 AUX OUT (+): (Typically for use with automatic gate lock or light) • Provides 12Vdc power @ a maximum of 2 Amps or less than 25 watts when the gate is in motion.
2 AUX OUT (-): (Typically for use with automatic gate lock or light) • Provides 12Vdc power @ a maximum of 2 Amps or less than 25 watts when the gate is in motion.
3 SOLAR PANEL (-) • Input for 18-22Vdc charge power from solar panel

4 18 VAC • Input for 18-22Vac charge power from transformer
9 CYCLE: (Typically for use with doorbell button or hardwired keypad) • Each activation at this input will cycle the operation as follows: ….→ OPEN → STOP → CLOSE → STOP → OPEN → …
10 COM: Circuit common (reference for all logic input) • Two (2) terminals to provide extra common connection point.


1 2 3 4 7 8 9 10 5 6
NO COM NC V + V – LOOP LOOP
1 2 3 4 5 6 7 8 9 10
Mighty Mule Vehicle Sensor Refer to Vehicle Sensor manual for additional connections.

The master opener's battery harness wire has an in-line 20 Amp fuse that must be placed inside the opener prior to closing the access panel. The illustration to the right shows the best place- ment for the battery harness wire, connector and in-line fuse, communication cable, receiver wire, transformer or solar panel and any accessories that have been installed. All wires must be routed down the sides of the opener and flatly out the slot in the back of the opener.
Mighty Mule 352 Master Opener Wire Routing
It is IMPORTANT that the wires lay flat and run inside the routing pins at the back of the opener and out the slot without being pinched when the control board access cover is replaced. See the illustrations to the right and below.
Neatly arrange all wires to lay flat as they come out of the opener.
The battery harness and communication cable must be routed down the sides of the opener and flatly out of the slot in the back of the opener.
Battery Harness Wires Transformer or Solar Wires Receiver Wires Communication Cable (LINK) Accessory Wires
It is IMPORTANT that the wires lay flat and run inside the routing pins at the back of the opener and out the slot without being pinched when the control board access cover is replaced. See the illustrations to the right and below.
To avoid stripping screw holes - tightening screws by hand with a hand held screwdriver is recommended.
Mighty Mule 352 Second Opener Wire Routing
Neatly arrange both wires to lay flat as they come out of the opener.
Battery Harness Wires Communication Cable
If you have any questions please call GTO Technical Service at 1-800-543-1236.

Final Step When everything has been connected to the opener...
Replace the control board access cover. If you were working with the opener with the control board access facing up, remove the opener arm from both mounts and remount it in the upright position (control board cover facing down). Failure to remount opener in the up right position will allow water to enter the opener and cause damage to the opener control board.

Swinging gates shall not open into public access areas!
"Push-to-Open" gates open out from the property. Push-to-Open Brackets are required for this type of installation (see Accessory Catalog). If you have pull-to-open gates (gate opens into the property), return to page 13; step 3. In a PUSH-TO-OPEN installation the opener is installed while the gate is in the closed position.
Step 1 With the gate in the closed position (up to 110º from its open position), and the opener fully retracted, adjust the post bracket assembly and gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate.
! &:]QYEOaVS`
IMPORTANT: While determining the mounting point for the post pivot bracket assembly, be sure that the position allows for minimum 2 inches of clearance between the gate and the opener in both the open and closed positions, as shown in the diagrams below. This clearance will give the opener the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area.
Step 2 After verifying that you have the best position for the post pivot bracket, insert the 5/16" x 1 3/4" bolt through the aligned holes of the post bracket and post pivot bracket and fasten it with the 5/16" washer and nut.
Pinch Area (gray)
Gate in the Closed Position
Pinch Area (gray)
2" minimum

With the gate in the fully closed position and the opener retracted, swing the opener to the gate. Mark reference points for bolt holes on gate cross member through middle of gate bracket slots. The opener must be level. (Some vertical adjustment is possible by sliding the post bracket assembly up and down.) Drill 3/8" holes into the gate cross member as marked. Fasten gate bracket to cross member using (2) 3/8" x 3" bolts, washers, lock washers, and nuts. Attach the opener to the post bracket assembly and gate bracket using clevis pins, bushings, and hairpins clips.

Fence Post Gate Post and Gate Cross Member (In Closed Position)
POST PIVOT BRACKET level with the horizontal surface of the GATE BRACKET
Step 4 Make sure the control box power switch is OFF. Use a small screwdriver to move the Number 1 DIP switch from the factory setting (OFF / Pull-To-Open) to ON for Push-To-Open. Turn power switch ON. The control board is now configured to push the gate open.
Step 1 Confirm that the power switch is in the ON position, and the gate is in the CLOSED POSITION.
Step 2 Activate your opener by pressing the entry transmitter. Your gates should now be moving from the fully CLOSED POSITION toward the opening position. Press the transmitter again to stop the gate at the desired OPEN position. Note: whichever gate reached its desired open position first that will be the first one to be programmed.


Save the setting by pressing the transmitter and allowing the gates to return to the fully closed position. YOUR OPEN POSITION LIMIT IS NOW PROGRAMMED.
Step 4 Repeat step 2-3 for the other arm that has not been programmed in step 2.
TESTING YOUR OPEN LIMIT SETTING: Press your entry transmitter and allow your gate to open. If OPEN position is not correct or needs to be changed you will need to CLEAR your OPEN LIMIT (see below) setting and follow steps 1 through 3 again.
CLEARING PROGRAMMED OPEN LIMIT SETTING: If you make a mistake and set the limit at the wrong position – press your transmitter to return the gate to its fully closed position, then press and hold the "SET LIMIT" button for the corresponding arm for 5 seconds. This will clear the memory for the open limit position. Follow Steps 1-3 again.


If your gate opener does not function properly after it is installed, use this guide or use the online troubleshooter at http://support.gtoinc.com/support/troubleshooter.aspx before calling the GTO Service Department.
13.8 to 14.8 vDC. Battery may be charged with a trickle charger at 12Vdc 2 amps for 3 to 4 hours but be sure to disconnect it from the system. 3. 1 beep when attempt to run the unit: - Blown fuse - Dead cell or extremely low battery condition. - Bad connection from battery to circuit board.

1 blink with 2 seconds off: Free Exit terminal is shorted to common. Check exit wand or loop detector. 2 blink with 2 seconds off: Safety terminal is shorted to common. Check photo beams or loop detector. 3 blink with 2 seconds off: Edge terminal is shorted to common. Check edge sensor. 4 blink with 2 seconds off: Cycle terminal is shorted to common. Check push button, wired keypad or wired intercom. LEARN LIMIT Mode: This LED will turn on when the ‘SET-LIMIT’ button is pressed. It will turn off after 3 seconds indicating that it has entered the learn limit mode (if not at the retracted limit) or cleared the previous learned limit (if at retracted limit). See "Setting Closed Position" section on page 27. Whenever there is a change in state at any of the inputs this LED will blink once. 3. POWER LED (Green): (MASTER ARM ONLY) ON: AC power or solar power is present. OFF: NO AC power or solar power is present. 4. CHARGING LED (Red): (MASTER ARM ONLY) Continuously ON: Fast charging mode. (~1.5 Amps charging current). 14.8 Vdc Blinking (two blinks per second): Soak charge. Enter this mode after fast charging. The battery is almost at full charge in this mode. 14.2 Vdc Slow blinking (one blink per second): Float charge. In this mode when the battery is fully charged. 13.8 Vdc
The Gate CLOSES Then Opens Again on its Own: 1. Check the position of the pivot and post brackets and readjust if necessary. 2. Check the gate for binding or hinge damage. 3. Reset closed position limit. 4. Adjust stall force.
The Gate OPENS Then Closes Again on its Own: 1. Check the position of the gate brackets and readjust if necessary. Take opener off gate. Retract tube with remote. Re-attach arm to see if hole in front mount aligns with hole in gate bracket. 2. Check the gate for binding or hinge damage. 3. Adjust stall force.
18 Vac Transformer 18.0 to 22.0 Vac
10 W Solar panel (single) 18.0 to 22.0 Vdc 600 mA measure voltage at panel and control box.
12 V Battery 12.5 to 13.5 Vdc
Charging circuit 13.8 to 14.8 Vdc measure voltage with battery connected

If your Mighty Mule® 352 Gate Opener is not operating properly, please follow the steps below:
For more information on Mighty Mule’s full line of Automatic Gate Openers and Access Controls visit our website at www.mightymule.com
The GTO, Inc. Technical Service Department is open
Monday – Friday 8:00 A.M. – 7:00 P.M. (Eastern Time)
GTO, Inc.
1-800-543-1236

IF THIS OPENER WILL BE USED WITH GATES THAT ARE MOUNTED ON MASONRY, BRICK, OR ROCK (etc.) COLUMNS:
A. The simplest solution is to install the opener in a push-to-open configuration (requires Push-To- Open Bracket, see Accessory Catalog). The minimum clearance is easier to achieve and clearance is no longer a problem, since the opener will be pushing the gate away from the column instead of pulling it toward the column. It is recommended that you place a steel plate between the opener mounting brackets and masonry surface for additional strength.
B. If a push-to-open installation is impossible due to traffic hazards, terrain, etc., another option is to re-hang the gate. You may hang it on a post, either in the center of the column or at the back corner, or move the gate to the back corner of the columns.
C. The most difficult solution is to cut a notch in the column to accommodate the opener and power cable. This job is NOT for the inexperienced!
Column Mount Example (A + B can not exceed 14 inches) Example: If A is 2" then B can not exceed 12"
Pivot Bracket
B
Gate
Column
Hinge


Solar Panel (FM123) 10 watt (FM121) 5 watt - requires two - 5 watt panels The Solar Panel is a 10 watt solar powered battery charger for use with the FM350 & FM352 gate operator systems. Particularly suited for remote installations, each Solar Panel comes with tubular steel support, mounting clips, wire connectors, and 8 ft. of low voltage wire (see Low Voltage Wire for additional wire). The Mighty Mule® 352 control board has clearly labeled terminal connections for easy installation of the Solar Panel. Installation in some regions of the world will require multiple solar panels for adequate charging power. Dual gates require a minimum of 10 watts of solar charging power. (5 watt panels require 2 panels)
Push Button Control (FM132) Unlit doorbell button for remote entry or exit control. Wires directly to the control board and uses 16 gauge multi-stranded, dual conductor low voltage wire (sold separately).
Pin Lock (FM133) The Pin Lock substitutes for the clevis pin at the front end of the Mighty Mule® 352 gate openers. Helps prevent theft of the operator from the gate, while allowing quick release of the operator.
Key Chain Two Button Transmitter (FM134) The Key Chain Transmitter is a dual button version of the Mighty Mule® single button entry transmitter and has the same adjustable code settings. Used for 2 gates or 1 gate and garage door. (battery is included)
Single Button Transmitter (FM135) The Mighty Mule® entry transmitter, with adjustable code settings, is standard equipment with all Mighty Mule® 352 systems. (battery is included)
Digital Keypad (FM137) The specially designed digital keypad can be easily installed as a wireless or wired keypad. It can be programmed to use up to 25 different personal identification number (PIN) codes. Each code is face programmable with additional security features built in. Wired installations require 16 gauge, low voltage, multi-stranded, dual conductor, direct burial wire (sold separately). Requires 3 AA batteries (not included).
Mounting Post (FM100) - In Ground This black powder coated pedestal is designed to provide convenient access to your keypad, wireless intercom, or other access control device from your vehicle. With its break down design it is easy to install and works well in most standard applications. Surface Mount Flanges (F102) and Extensions (F103) for added height are available.
Mighty Mule® Vehicle Sensor (FM138) The Gate Opening Sensor is designed for residential and agricultural applications and is compatible with most Mighty Mule® automatic gate opener models (see Sensor Box for model compatibility). The Sensor is an electromagnetic sensor, which offers 'hands free' operation of the Mighty Mule® Gate Operator with a 12 ft. radius of detection of vehicles in motion. A wireless version of the Gate Opening Sensor is available. (FM130)

Automatic Gate Lock Pull-to-Open (FM143) A MUST for added security. Solenoid driven, with a steel housing. Unlocks and locks automatically as gates open and close. Used with Mighty Mule® DC swing gate operating systems for maximum stability and security. Comes with a keyed manual release. Recommended for gates over 8 ft. long. Ideal for animal enclosures or high wind areas.
Wireless Entry Intercom / Keypad (FM136) Allows owner to screen guest at the gate before allowing access to the property. Keypad also allows owner to give up to 25 programmable entry codes to family, friends or approved delivery personnel. Codes can be permanent of temporary. Can be wireless up to 500 feet or hard wired up to 1000 feet. Additional base stations available (F3101MBC).
Low Voltage Wire (RB509) The 16 gauge, multi-stranded, dual conductor Low Voltage Wire is for connecting the AC powered transformer, or the Solar Panel to the control board. Also used for the connection of accessories, such as locks, keypads, push buttons and other wired control devices. This specially designed wire is UV treated, PVC coated and ready for direct burial. Available in 1000' rolls or special lengths.
Driveway Alarm (FM131) Keep track of the comings and goings on your property with this electromagnetic sensor alert system. When a vehicle passes the sensor, the receiver emits an audible tone and lets you know someone’s there. Functional range of up to 400 ft. Easy-to-install and stake is included in kit. Transmitter requires 2 “C” batteries (not included)
Wireless Driveway Vehicle Sensor (FM130) The wireless gate opening sensor offers hands free operation of the Mighty Mule Gate Opener. Works wirelessly up to 100 feet from the gate. Transmitter, receiver and two AA batteries are included.
Push to Open Bracket (FM148) Required when Mighty Mule® 350/352 gate operator(s) must push the gate open, such as on a sloping driveway or where space prevents gate(s) from opening inward (pulled open). Order two PTO brackets for conversion of a dual swing gate installation.
Column Mount Lock Receiver (433IH) For mounting the Automatic Gate Lock on brick columns, walls, or for other applications with limited space between gate and post.
Replacement Transformer (RB570) Standard 18 volt, 2200 mA, AC transformer for maintaining the battery included with the Mighty Mule® 352 gate operator. This is the only transformer approved for use with all UL325 Mighty Mule® gate operator systems.
Universal Receiver (RB709U-NB) The Universal Receiver allows you to use the same Mighty Mule® 352 entry transmitter to operate your gate operator and your garage door operator. Compatible with most garage door operators.
just call 1-800-543-GATE!
The contents of all material available on this installation manual are copyrighted by GTO, Inc. (“GTO”), unless otherwise indicated. All rights are reserved by GTO, and content may not be reproduced, downloaded, disseminated, published, or transferred in any form or by any means, except with the prior, written permission of GTO. Any reprinting of GTO publications is by
permission only. Copyright infringement is a violation of federal law.
Mighty Mule¨, E-Z Gate¨, GTO¨, are registered trademarks of GTO, Inc. America’s DIY Automatic Gate Openers is a trademark of GTO, Inc. and are the exclusive property of GTO, Inc.
(“GTO”). All rights are reserved by GTO, and these marks may not be used, in any for without the prior, written permission of GTO.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.