EN
Grindmaster logo
Official user manual

Grindmaster APBIC-430V2E230

44 pages·1.7 MB·Coffeemaker·PDF·ENDEFRITNLJA
Grindmaster APBIC-430V2E230
Table of Contents 80 sections Shuttle ® Brewer & Airpot/Shuttle ® Brewers · Operation and Instruction Manual · APBIC-430V2, APB-330V2E230, APB-430V2E230, APBVSA-330V2E230, · APBVSA-430V2E230, APBIC-330V2E230, PBIC-430V2E230 · … ShowHide
Shuttle ® Brewer & Airpot/Shuttle ® Brewersp.1Operation and Instruction Manualp.1APBIC-430V2, APB-330V2E230, APB-430V2E230, APBVSA-330V2E230,p.1APBVSA-430V2E230, APBIC-330V2E230, PBIC-430V2E230p.1Table of Contentsp.1APBIC-430V2E230p.1APBVSA-430V2E230p.1Warning Labelsp.3Installationp.4WARNINGp.4ELECTRIC SHOCK HAZARD!p.4Set-Up/Positionp.4Water Hook-upp.4Installation (cont.)p.5Electric Hook-upp.5YELLOWp.5ORANGEp.5TO CONTROLLERp.5REDp.5TRANSFORMERp.5208V BLUEp.5120V WHITEp.5FROM L1 BLACKp.5Start-upp.6Operationp.6CAUTIONp.6HOT LIQUID HAZARD!p.6Adjustmentsp.7Adjustments (cont.)p.8Control Featuresp.8Programmingp.8To enter program mode:p.8Programming (cont.)p.9Programming Sequence for Large Left Portionp.11Table 1p.11OG G O S Sp.11DISPLAYp.11READINGp.11ADJUSTp.11ADVANCEp.11ORp.11TEMP SCALEp.11TANK TEMP (170-202F) ORp.11ENERGY MODEp.11LOW-TEMP/NO-BREWp.11LOW-TEMP/p.11NO-BREWp.11DRIP TIMEp.11DRIP TIME PERCENT OF BREWp.11TOp.11BYPASS RATIOp.11BREW TIMEp.11BREW TIME (.01 TO 6.00)p.11PRE INFUSIONp.11PRE INFUSION TIME (OFF TO 2.00) TOp.11Programming Sequence for Large Left Portion (cont.)p.12Table 1 (cont.)p.12READING DISPLAYp.12PRE INFUSION OFF TIME TOp.12(.05 TO 2.00)p.12PULSE BREWp.12# OF PULSESp.12(OFF, 1 - 10)p.12PULSE ONp.12PULSE ON TIME (0:05-2:00)p.12PULSE OFFp.12PULSE OFF TIME (0:05-2:00)p.12BY-PASSp.12OFF TO .25 PERCENTp.12COPY TO LEFTp.12Programming Sequence for Medium Portionsp.13Table 2p.13DISPLAY WILL READ AS FOLLOWS:p.13BREW TIME (.01 TO 6.00) p.13 PRE INFUSION TIME (OFF TO 2.00)p.13PRE INFUSION OFF TIMEp.13 (.05 TO 2.00)p.13Programming Sequence for Medium Portions (cont.)p.14Table 2 (cont.)p.14ADJUST READING ADVANCEp.14
Page 1 of the Grindmaster APBIC-430V2E230 user manual — Table of Contents
Page 1 · Contents
Contents

Contents

Shuttle ® Brewer & Airpot/Shuttle ® Brewersp.1Operation and Instruction Manualp.1APBIC-430V2, APB-330V2E230, APB-430V2E230, APBVSA-330V2E230,p.1APBVSA-430V2E230, APBIC-330V2E230, PBIC-430V2E230p.1Table of Contentsp.1APBIC-430V2E230p.1APBVSA-430V2E230p.1Warning Labelsp.3Installationp.4WARNINGp.4ELECTRIC SHOCK HAZARD!p.4Set-Up/Positionp.4Water Hook-upp.4Installation (cont.)p.5Electric Hook-upp.5YELLOWp.5ORANGEp.5TO CONTROLLERp.5REDp.5TRANSFORMERp.5208V BLUEp.5120V WHITEp.5FROM L1 BLACKp.5Start-upp.6Operationp.6CAUTIONp.6HOT LIQUID HAZARD!p.6Adjustmentsp.7Adjustments (cont.)p.8Control Featuresp.8Programmingp.8To enter program mode:p.8Programming (cont.)p.9Programming Sequence for Large Left Portionp.11Table 1p.11OG G O S Sp.11DISPLAYp.11READINGp.11ADJUSTp.11ADVANCEp.11ORp.11TEMP SCALEp.11TANK TEMP (170-202F) ORp.11ENERGY MODEp.11LOW-TEMP/NO-BREWp.11LOW-TEMP/p.11NO-BREWp.11DRIP TIMEp.11DRIP TIME PERCENT OF BREWp.11TOp.11BYPASS RATIOp.11BREW TIMEp.11BREW TIME (.01 TO 6.00)p.11PRE INFUSIONp.11PRE INFUSION TIME (OFF TO 2.00) TOp.11Programming Sequence for Large Left Portion (cont.)p.12Table 1 (cont.)p.12READING DISPLAYp.12PRE INFUSION OFF TIME TOp.12(.05 TO 2.00)p.12PULSE BREWp.12# OF PULSESp.12(OFF, 1 - 10)p.12PULSE ONp.12PULSE ON TIME (0:05-2:00)p.12PULSE OFFp.12PULSE OFF TIME (0:05-2:00)p.12BY-PASSp.12OFF TO .25 PERCENTp.12COPY TO LEFTp.12Programming Sequence for Medium Portionsp.13Table 2p.13DISPLAY WILL READ AS FOLLOWS:p.13BREW TIME (.01 TO 6.00) p.13 PRE INFUSION TIME (OFF TO 2.00)p.13PRE INFUSION OFF TIMEp.13 (.05 TO 2.00)p.13Programming Sequence for Medium Portions (cont.)p.14Table 2 (cont.)p.14ADJUST READING ADVANCEp.14
Page 3 of the Grindmaster APBIC-430V2E230 user manual — Warning Labels
Page 3 · click to enlarge
Page 3

Warning Labels

The following warning labels were on your dispenser when it was shipped from the factory. They should remain on your dispenser in good, readable condition at all times. If one of your labels is missing or damaged, order a replacement label immediately.

Part # A546-445 Located on front splash panel and lid of machine.

Grindmaster APBIC-430V2E230 — Warning Labels diagram (page 3)
Fig. 1 · Warning Labels

Located on APB-330V2, APB-330V2E230, APB-430V2, and APB-430V2E230 lower front decal. Order part # A546-434 for APB-330V2. Order part # A546-435 for APB-430V2.

Located on APBIC-330V2, APBIC-330V2E230, APBIC-430V2, and APBIC-430V2E230 above faucet. Order part # A546-428 for APBIC-330V2. Order part # A546-427 for APBIC-430V2.

Part # A71949 Located on brew baskets.

Grindmaster APBIC-430V2E230 — Warning Labels diagram (page 3)
Fig. 2 · Warning Labels
Page 4 of the Grindmaster APBIC-430V2E230 user manual — Water Hook-up
Page 4 · click to enlarge
Page 4

Installation

WARNING

ELECTRIC SHOCK HAZARD!

Installation of this appliance should be performed by qualified service personnel only. Improper installation could result in electrocution.

Set-Up/Position

1. Remove the brewer from the packing material and attach its legs.
2. Position the brewer on a strong, stable table or counter. Check the level front to back and side to side. Adjust the legs to the correct level.

The electric and water hook-up locations are behind the front panel. Remove the four screws fastening this panel for access to these connections.

Water Hook-up

1. The water line may enter through holes on the rear or the bottom of the brewer. Use the right hand opening for water.
2. Use 3/8” copper or flexible water line to prevent strain. Do not use low temperature plastic tubing. The connection to the fill valve is 3/8” flare.
3. Water line pressure must be from 30 to 80 psi (207-2 KPA).
4. Hot (up to 160°F/71°C) or cold water may be used. Hot water offers faster recovery between brews.
5. Install a shut-off valve near the brewer.
6. Installing a filtering system can improve the taste of brewed coffee and extend the life of the brewer. If your water has high calcium (lime), chlorine, or iron content, this is especially important. The filter should be the lime inhibiting type if cold water is used.
Page 5 of the Grindmaster APBIC-430V2E230 user manual — WARNING
Page 5 · click to enlarge
Page 5

Installation (cont.)

Electric Hook-up

The brewer is designed to operate at the specified voltage on the nameplate with a tolerance of ± 10% for voltage deviation. It is very important that the power line to the brewer be checked to make sure that the voltage is within 10% of the brewer’s rated voltage. Failure to provide adequate voltage, as defined above, will cause problems with your brewer. If the power is too low, the solenoid valves may or may not work or longer recovery time will be experienced. The brewer may be permanently damaged if the voltage is too high.

1. The electric ratings for your brewer are printed on its nameplate.
2. The brewer should be connected to its own circuit with a fused disconnect switch or a circuit breaker near the brewer.
3. Attach the appropriately sized cord to the brewer with a cord grip for the 1 1/2” (3.8 cm) electric input opening. The cord may enter through the rear or bottom on the left side of the brewer. Use an oil resistant cord such as type SO, SOO, SAO, STOO, SEO, SJO, SJOO, SJTO, SJTOO, SJEO, HSO, HSOO, HSJO, or HSJOO. Alternatively, flexible conduit and type THHN wires may be used. Use only copper conductors.

4) Standard connection is 1 phase 3 wire. Connect the two lines to L1 and L2 on the terminal block. If the brewer is wired for three phase, a lug, L3, is provided on the terminal block. Neutral line should be connected to the N terminal. Alternately, if no neutral is available, the brewer can be wired accordingly by connecting L1 to position marked “L1” and L2 to position marked “L2”. This will require the installer to change the connection to the transformer primary from the white wire (120V) to the blue (208V) or orange (230,240V) connection. See below. NOTE: This “no neutral” conversion is only applicable to units marked as 208V, 230V, or 240V. It is NOT applicable to units marked 120/208V or 120/240V.

Note: The brewer utilizes a multiple tap primary transformer to convert line voltage to 24 volts for use by the controller and some operating controls. The transformer has taps for 120V (white wire), 208V (blue wire), and 240V (orange wire) line voltage. Be sure to connect the white wire from the terminal block to the proper tap for the supplied voltage. See diagram below.

YELLOW

ORANGE

TO CONTROLLER

RED

TRANSFORMER

208V BLUE

WHITE FROM TERMINAL BLOCK *N-120V *L2 -208V or 230V

YELLOW

120V WHITE

FROM L1 BLACK

5. The body of the brewer must be grounded. A ground lug is provided for this purpose.

Never use the ground conductor as a neutral. This could cause electrocution.

WARNING

Page 6 of the Grindmaster APBIC-430V2E230 user manual — CAUTION
Page 6 · click to enlarge
Page 6

Installation (cont.)

Start-up

1. Flip power supply to machine “ON” at the branch supply disconnect and allow the water tank to fill. The machine will make a subtle hissing sound while filling.
2. Once the brewer is full, it will take 15 to 35 minutes to heat. The ready lights will turn on when up to temperature.
3. Insert the brew baskets and place a Shuttle or airpot under the baskets. Brew at least one batch from each side. Check the level in the container to be sure the brew volume is correct. Remember that when using coffee, the level will be lower. Do this for all batch sizes. The water must be hot to check the levels. If adjustments are needed, see the adjustments section of this manual.

Operation

CAUTION

HOT LIQUID HAZARD!

Water used for brewing coffee is very hot. Use caution when brewing, pouring, or transporting coffee. Accidental spills may result in severe burns.

1. Place an empty, warm Shuttle on the shelf, under the brew head. Turn on the warmer if available.
2. If the Shuttle is not warm, allow the warmer to heat the Shuttle. Only a short brew of water will speed this. A cold Shuttle will significantly lower the temperature of the brewed coffee.
3. Remove the filter basket and line with a filter paper. Paper size is 13 x 5 for the smaller basket, BB1.5, and 14 x 6 for the larger, BB2.0.
4. Place ground coffee in the filter basket. Follow corporate recommendations for amount of coffee and grind. A full Shuttle is 1.5 gallons (5.7L). A full vacuum Shuttle is 1.6 (6.0L) gallons.
5. Slide the basket into the brewer making sure the spout lines up with the top of the Shuttle.
6. If ready lights are lit, press correct batch size button.
7. Brew spray time is about 4 minutes for a full Shuttle. After the brew, allow the coffee to drip for 1 to 2 minutes. Ready light will flash during the entire brew spray and drip cycle. Brew basket will be locked in place until drip cycle is finished.

CAUTION

Coffee basket contains very hot water until the drip is completed. Early removal of a dripping basket could result in burns.

8. Dump the grounds from the basket and rinse for the next brew. Coffee is ready to serve.
9. The Shuttle may be placed on remote warming stations. Use caution when moving a full Shuttle.
Page 7 of the Grindmaster APBIC-430V2E230 user manual — Adjustments
Page 7 · click to enlarge
Page 7

Adjustments

All adjustments to machine are accessible through the front display(s). Refer to specifics below and the Programming Routine section. All values are preset at the factory and may vary brewer to brewer.

Temperature Adjustment Tank temperature can be adjusted from 170°F – 205°F (77°C – 96°C) through the front display. See Programming Routine section for procedure.

This brewer can be set for maximum water temperature of 205°F (96°C). The boiling point of water is lower as altitude increases. The setpoint temperature of the brewer should be maintained below the boiling point at a given elevation. Refer the to the chart below for recommended maximum setpoint for given altitudes.

Altitude (ft)Approximate Boiling PointRecommended Max. Temperature °F°C°F°C 021210020596.1 500211.199.520495.6 1000210.299.020395.0 1500209.398.520294.4 2000208.498.020193.9 2500207.597.520093.3 3000206.697.019992.8 3500205.796.519992.8 4000204.896.019892.2 4500203.995.519791.7 500020395.019691.1 550020294.419590.6 6000201.193.919490.0 6500200.293.419389.4 7000199.392.919288.9 7500198.392.419188.3
Grindmaster APBIC-430V2E230 — Adjustments diagram (page 7)
Fig. 3 · Adjustments
THERMISTOR CURVE FOR PART # A725-097 °C°FRESISTANCE (OHMS)°C°FRESISTANCE (OHMS) 03216325601401244 54112697651491041 1050995170158875 1559785675167740 2068624680176628 2577500085185535 3086402890194458 3595326695203393 401042663100212339 451132185105221294 501221802110230255 551311493
Page 8 of the Grindmaster APBIC-430V2E230 user manual — To enter program mode:
Page 8 · click to enlarge
Page 8

Adjustments (cont.)

Brew Volume “br” Brew time can be set for each size visually. See Setting Brew Volume Procedure below. Brew time can also be adjusted through the display. See Programming Routine section.

Setting Brew Volume Visually 1. Remove brew basket and place container under brew head. 2. Press and hold desired brew button for 5 seconds. Display will read “Pro”. 3. Within 20 seconds, press and release desired brew button. Water will dispense from spray head and time will count-up in display. 4. When volume is at desired amount, press and release brew button to stop flow. Time will flash in display. 5. Within 20 seconds, press and release desired brew button. Display will clear and brew time will be stored into memory. Note: During this routine, no pulsing or bypass will occur. Note: If the On/Off button is pressed during procedure, time setting will default to previous time.

Control Features

Pre-infusion: Controls the initial coffee grounds wetting and the first dwell time after the initial wetting. Pulse brews are the series of pulses after the Pre-infusion process. All pulse ON and OFF times are the same.

Brew Countdown Timer: After the start of a brew the LED display will countdown the remaining time left in the brew process. The countdown will include all OFF periods programmed in the Pre-infusion and the pulses. At the end of the brew time, the display will scroll driP, while the brew basket drains itself. At the end of the drip cycle, the display will scroll doneE for 30 seconds then turn off.

Energy Savings Mode: If enabled, when the brewer is idle for three (3) hours this feature will allow the water tank to lower its holding temperature to 120°F. The display will scroll SLEEPIng while in this mode. To exit energy savings mode press any button and the unit will start reheating to brewing temperature.

Copy-to-Left: On twin brewers, this feature allows you to copy the brew parameters programmed on a particular brew portion on the Right side to the Left side.

Programming

On twin brewers, the right side, Large portion button gives the user access to the global programming parameters of the brewer, such as; Tank Temperature, Energy Savings Mode, Enable/Disable Low Temp No Brew, ON/OFF, Drip Time and Bypass Ratio. After the global parameters are set, the individual portion brew parameters can be set. All other portion sizes (left and right) only access individual brew parameters to that particular portion. Also, on twin brewers, the last program step in programming individual brew parameters allows the operator to copy those brew parameters to the left side if “YES” is selected. If “YES” is selected, the brew parameters that were set for the right side for that particular portion are copied to the left side. If “NO” is selected, then the left side must be programmed separately.

To enter program mode:

Press the UP and DOWN arrows simultaneously for 5 seconds. Once in program mode, the green LED for each por- tions size will flash.

Page 9 of the Grindmaster APBIC-430V2E230 user manual — Programming (cont.)
Page 9 · click to enlarge
Page 9

Programming (cont.)

To program the following items, press the Large, Right side portion button. (refer to Table 1)

1. Temperature Scale: Choose °F or °C
2. Set Water Tank Temperature: Choose between 170°F - 205°F
3. EnErGy mOdE: Choose YES or NO
  • 4) Ltn (Low Temp No Brew): Choose YES or NO
  • If YES, the brewer will only allow a brew to begin if the water tank temperature is within 5°F of set point.
  • If NO, the brewer will brew at any temperature.

5) DriP time: Choose from 40% to 80% of brew time. This is the amount of time the brewer takes to completely drain the brew basket after the brew valve closes. The factory default is 50%, so if the brewer is set for a 1.5 gallon brew, without pre-infusion and pulses, the brew basket will remain locked for 2 minutes after the brew valve closes. If, with coffee, the brew basket drips for longer than 2 minutes, increase the setting to 60% which will be 2:24 of drip time. The setting increases by 5% increments; 12 seconds each.

  • 6) rto (Set Bypass Ratio): Choose Std or Grm
  • Choose Std if you are using the standard sprayhead.
  • Choose Grm if you are using the gourmet sprayhead.

Bypass ratio is the last global program parameter to be set. The following are the individual brew portion parameters. Each portion button can have individual brew sequences.

7. Br time (Brew time): Choose between 0:01 to 6:00 minutes. This time setting controls the brew volume. The brewer brews at a rate of 1.5 gallons in four minutes (48 ounces per minute / 0.8 ounces per second). The Large portion button is factory set to brew 1.5 gallons or 4 minutes of brew time. Adjust the brew volume to desired level. One second of brew time will change brew volume by 0.8 ounces.
8. PrE inFuSion : Choose OFF to 2:00 minutes. This is the amount of pre-infusion desired with the batch of coffee. If no pre-infusion is desired then set to OFF .
9. PrE inFuSion oFF : Choose 0.05 to 2:00 minutes. This is the OFF time that allows the brew basket to drain the Pre-infused volume of water.
10. PuLSE br : Choose OFF to 10 This will set the number of brew pulses desired. If none are desired, then set to OFF .
11. PuLSE on (Pulse ON time): Choose 0:05 - 2:00 minutes If pulses are set to 10, program the ON time for the pulses. The same ON time is used on all pulses.
12. PuLSE oFF (Pulse OFF time): Choose 0:05 - 2:00 minutes If pulses are set on step 10, then program the OFF time for the pulses. The same OFF time is used on all pulses.
Page 10 of the Grindmaster APBIC-430V2E230 user manual — Programming (cont.)
Page 10 · click to enlarge
Page 10

Programming (cont.)

13. By-PASS (Set bypass volume): Choose OFF to 25% Set the amount of bypass desired during brew. If none is desired then set to OFF, otherwise, set the % of brew volume to bypass.
14. CoPY-to-LEFt : Choose YES or no If the same program parameters are desired on same portion size on the left side, then choose YES and the parameters will be copied.

The sequence of programming for the Medium portion is as follows: (refer to Table 2)

1. Br time (Brew time): Choose 0:01 - 6:00 minutes
2. PrE inFuSion : Choose OFF to 2:00 minutes
3. PrE inFuSion oFF : Choose 0:05 to 2:00 minutes
4. PuLSE br (Pulse Brewing): Choose OFF to 10
5. PuLSE on (Pulse ON time): Choose 0:05 - 2:00 minutes
6. PuLSE oFF (Pulse OFF time): Choose 0:05 - 2:00 minutes
7. By-PASS (Set bypass volume): Choose OFF - 25%
8. CoPY-to-LEFt : Choose YES or no

The sequence of programming for the Small portion is as follows: (refer to Table 3)

1. Br time (Brew time): Choose 0:01 - 6:00 minutes
2. PrE inFuSion : Choose OFF to 2:00 minutes
3. PrE inFuSion oFF : Choose 0:05 to 2:00 minutes
4. PuLSE br (Pulse Brewing): Choose OFF to 10
5. PuLSE on (Pulse ON time): Choose 0:05 - 2:00 minutes
6. PuLSE oFF (Pulse OFF time): Choose 0:05 - 2:00 minutes
7. CoPY-to-LEFt : Choose YES or no
Page 11 of the Grindmaster APBIC-430V2E230 user manual — DISPLAY
Page 11 · click to enlarge
Page 11

Programming Sequence for Large Left Portion

Table 1

OG G O S S

PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. DISPLAY WILL READ AS FOLLOWS:

DISPLAY

READING

ADJUST

ADVANCE

OR

TEMP SCALE

TANK TEMP (170-202F) OR

ENERGY MODE

ENERGY MODE

OR

LOW-TEMP/NO-BREW

LOW-TEMP/

OR

NO-BREW

DRIP TIME

DRIP TIME PERCENT OF BREW

TO

BYPASS RATIO

OR

BREW TIME

BREW TIME (.01 TO 6.00)

PRE INFUSION

PRE INFUSION TIME (OFF TO 2.00) TO

continued on next page

Show 4 more labels / short text on this page
· · ·
Page 12 of the Grindmaster APBIC-430V2E230 user manual — Table 1 (cont.)
Page 12 · click to enlarge
Page 12

Programming Sequence for Large Left Portion (cont.)

Table 1 (cont.)

READING DISPLAY

ADJUST

ADVANCE

PRE INFUSION

PRE INFUSION OFF TIME TO

(.05 TO 2.00)

PULSE BREW

# OF PULSES

TO

(OFF, 1 - 10)

PULSE ON

PULSE ON TIME (0:05-2:00)

PULSE OFF

PULSE OFF TIME (0:05-2:00)

BY-PASS

OFF TO .25 PERCENT

TO

COPY TO LEFT

OR

Page 13 of the Grindmaster APBIC-430V2E230 user manual — DISPLAY WILL READ AS FOLLOWS:
Page 13 · click to enlarge
Page 13

Programming Sequence for Medium Portions

Table 2

OG G O S S

PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS.

DISPLAY WILL READ AS FOLLOWS:

READING DISPLAY

ADJUST

ADVANCE

BREW TIME

BREW TIME (.01 TO 6.00)

PRE INFUSION

PRE INFUSION TIME (OFF TO 2.00)

TO

PRE INFUSION

PRE INFUSION OFF TIME

TO

(.05 TO 2.00)

PULSE BREW

# OF PULSES

TO

(OFF, 1 - 10)

PULSE ON

PULSE ON TIME (0:05-2:00)

PULSE OFF

PULSE OFF TIME (0:05-2:00)

BY-PASS

OFF TO .25 PERCENT

TO

continued on next page

Show 15 more labels / short text on this page
· · · · · · · · · · · · · ·
Page 14 of the Grindmaster APBIC-430V2E230 user manual — DISPLAY WILL READ AS FOLLOWS:
Page 14 · click to enlarge
Page 14

Programming Sequence for Medium Portions (cont.)

Table 2 (cont.)

PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS.

DISPLAY WILL READ AS FOLLOWS:

DISPLAY

ADJUST READING ADVANCE

COPY TO LEFT

OR

· ·

Page 15 of the Grindmaster APBIC-430V2E230 user manual — DISPLAY
Page 15 · click to enlarge
Page 15

Programming Sequence for Small Portions

Table 3

OG G O S S

PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. DISPLAY WILL READ AS FOLLOWS:

DISPLAY

ADJUST READING

ADVANCE

BREW TIME

BREW TIME (.01 TO 6.00)

PRE INFUSION

PRE INFUSION TIME (OFF TO 2.00)

TO

PRE INFUSION

PRE INFUSION OFF TIME

TO

(.05 TO 2.00)

PULSE BREW

# OF PULSES

TO

(OFF, 1 - 10)

PULSE ON

PULSE ON TIME (0:05-2:00)

PULSE OFF

PULSE OFF TIME (0:05-2:00)

COPY TO LEFT

OR

·

Page 16 of the Grindmaster APBIC-430V2E230 user manual — Weekly or Bi-Weekly, Depending on Use
Page 16 · click to enlarge
Page 16

Cleaning

WARNING

Hot liquids and surfaces are present in this equipment. To avoid burns use caution when cleaning. Rinse hot parts with cold water before cleaning. Use gloves or a heavy cloth when removing hot parts from brewer.

After Each Brew:

1. Dispose of grounds and rinse brew basket.
2. Rinse Shuttle or airpot containers before reuse.

Every Day:

1. Wash brew basket with warm soapy water. The wire basket is removable to aid cleaning.
2. Remove spray head(s), located above brew basket(s), using gloves or a heavy towel. Wash off coffee oils and clean any plugged holes.
3. Clean Shuttles with warm soapy water and a brush or towel.
4. Use only a soft cloth and warm soapy water or stainless steel polish on the outside to avoid scratches.
5. Wipe exterior of brewer with a damp cloth. Do not use abrasives which will scratch surface.
6. If Shuttles are to be left on warmer all night, fill with water to avoid coffee oil burn-in.

Weekly or Bi-Weekly, Depending on Use

11) Fill Shuttles with one gallon, 2/3 full, of hot water.

12) Pour into the Shuttle liners the recommended concentration of urn cleaner (excessive amounts of cleaner will attack the stainless steel).

Urn cleaners that have been used successfully:

DIP-IT TABZ™ Super Concentrate manufactured by Reckitt Benckiser, Inc. manufactured by Urnex Brands, Inc. 1655 Valley Road 170 Ludlow Street Wayne, NJ 07474 Yonkers, NY 10705 (800) 228-4722 or (973) 633-3600 (800) 222-2826 or (914) 963-2042

13) Scrub the liner interior with a plastic bristle brush.

14) Remove the knurled nut at the top of the gauge glass and clean the glass with a small bottle brush.

15) Pour out the contents of the Shuttle.

16) Remove the handle assembly of the Shuttle faucet by unscrewing the plastic bonnet.

17) Gently wash the faucet seat cup with a soft cloth and warm soapy water.

18) Wash the faucet shank with a bottle brush.

19) Soak airpot pick-up tube assembly in hot soapy water. Urn cleaner may be used for stronger cleaning.1

10. Clean the warmer and bottom of Shuttle surfaces. These surfaces must be clean for proper heat transfer.
11. Polish the exterior of the brewer with stainless steel cleaner. Use the appropriate cleaner for brass, copper, or vinyl if these optional finishes are provided.

Burn Hazard!

Page 17 of the Grindmaster APBIC-430V2E230 user manual — Remove Heater
Page 17 · click to enlarge
Page 17

Service

The rest of this manual contains information to aid the service person who is working on this equipment. This page has information on performing common service tasks. Following this is the Troubleshooting section which can help diagnose problems which are divided into three basic systems: filling, heating, and brewing.

Next is an illustrated parts breakdown which will help in the selection of repair parts. If further assistance is needed, call our Technical Service Department at 800-695-4500 (USA & Canada only) or (502) 425-4776 Monday – Friday between 8:00 am and 6:00 pm Eastern time.

Wiring diagrams are also provided. Locate the basic diagram for the model you are working with. If there are any options, see Diagram #091-548 (page 33 of this manual) which shows the wiring alterations for options.

Drain Water Tank

Always empty the tank before shipping.

WARNING

Draining of tank should be performed by a qualified service technician. The tank contains very hot water. May cause severe burns.

1. Prepare a heat resistant container to drain tank water into.
2. Disconnect power to the brewer.
3. Remove the front access panel.
4. Pinch or clamp the silicone hose connected to fill valve.
5. Disconnect hose from outlet barb on fill valve.
6. Place hose over drain and release clamp.
7. Allow the tank to drain completely.

Remove Brew Valve

1. Disconnect power to machine.
2. Remove top cover and remove wires and small tube from valve.
3. Tilt inlet of valve down and pull sideways out of spray tee.
4. Clamp rubber tubing and disconnect valve from tubing.

Remove Heater

1. Disconnect power and remove top cover of brewer.
2. Disconnect wire leads to heater.
3. Remove tank cover by loosening retaining screw(s). Cover is lifted up with heater attached. Heater is then removed.
4. Replace heater with sealing washers in same configuration. When tightening nuts, hold element so it does not twist.
5. Replace tank cover ensuring gasket seal is good.
6. Replace heater wires. Be sure all electrical connections are secure.
Page 18 of the Grindmaster APBIC-430V2E230 user manual — Factory/Field Test Menu
Page 18 · click to enlarge
Page 18

Special Control Functions

User Lockout

User Lockout is achieved via the position of the LOCK jumper on the board header. Locate the header on the board (shown below) and place the jumper in the desired position. In the Locked position all menus in this document are locked out, and the unit will only allow brewing functions. There are two versions of the header, 10 pin and 2 pin. Both configurations are shown below.

10 Pin Version

2 Pin Version

UNLOCKED

UNLOCKED

LOCK

LOCK

LOCKED

LOCKED

LOCK

LOCK

System Restore Function

This function will restore a Precision Brew® unit to its original factory settings. To activate system restore, power on the unit while holding in the DOWN button on the keypad (use the keypad that controls the RIGHT side for a double unit).

Continue holding the DOWN button and the display will scroll “rEStorE” to indicate that a system restore is about to happen. If the DOWN button is released at this point, the restore is cancelled. If the button hold is continued, the display will scroll “donE” to show completion of a system restore.

Upon a successful restore, the original factory settings will override all changes. The brew counters are not affected.

Factory Specific Features

The following sections describe features that are not intended to be used by the end user. These features, instead, are intended to help Grindmaster set up and test the machine.

Factory/Field Test Menu

This menu is intended to check product functionality both at the end of the factory line and in the field. The con- trol must be completely OFF (both sides) to enter field test. This mode is entered by pressing and holding the UP key and the LARGE BREW key on the keypad (use the keypad that controls the RIGHT side for a double unit) for 6 seconds. Once the menu is entered, the unit will start with an LED test that lights all LEDs and segments on the display.

Proceeding through the field test is done by pressing the ON/OFF key (RIGHT side if a double unit). Each time this button is pressed, the test will advance to the next step. For the output test, use the UP and DOWN keys to select the desired output.

Refer to the table on the following page for operation. Field Test Mode exits after stepping through all modes only- there is not a timeout.

Page 19 of the Grindmaster APBIC-430V2E230 user manual — Factory/Field Test Menu (cont.)
Page 19 · click to enlarge
Page 19

Factory/Field Test Menu (cont.)

Step Function Operation Description

1 LED Test All LEDs ON Verify that all LEDs turn on.

2 Firmware Version Display firmware version Shows the software version of the control.

3 Date Code Not used Not used

4 EEPROM Version Not used Not used

5 Non Resetable Unit Counter

Scroll non-resetable unit counter Shows the total number of brews made by the brewer (both sides if a double unit)

6 Display Water Temperature

Show averaged A/D reading of temperature Shows the current temperature in °F of the

thermister.

7 Display Water Level 1 Show averaged A/D reading of water level 1 If > 500 water level is full,

If < 500 water level is not full.

8 Display Water Level 2 Show averaged A/D reading of water level 2 If > 500 water is at the heater level,

If < 500 water level not at the heater level.

9 Show Input Display scrolls “InPut” Input Test Mode

10 Input Test Press each key and the display will show a number related to that key

Right Side On/Off - 1 (advances test) Up - 5 Down - 3 Large Brew - 4 Medium Brew - 2 Small Brew - 0 Basket Switch - 17 Left Side On/Off - 9 Up - 13 Down - 11 Large Brew - 12 Medium Brew - 10 Small Brew - 8 Basket Switch - 16

11 Show Output Display scrolls “outPut” Output Test Mode

Scroll through relay outputs with the UP and DOWN keys.

12 Output Test Turns on each relay separately. Displays “O##“ where:

## = 2 digit output number

Outputs are as follows:

O01 - Fill Valve O02 - Right Bypass Valve O03 - Left Bypass Valve O04 - Right Brew Valve O05 - Left Brew Valve O06 - not used O07 - Tank Heater O08 - Right Basket Lock O09 - Left Basket Lock O10 - not used

Page 20 of the Grindmaster APBIC-430V2E230 user manual — Overfilling water tank only when power is On
Page 20 · click to enlarge
Page 20

Troubleshooting

The following pages are provided to help determine the cause of problems with operation of the brewers and to indicate the appropriate solution for the problems. For each problem, the possible causes should be checked in the order shown until the exact nature of the problem is determined.

The following procedures must be performed by a qualified service technician. Disconnect power to machine before servicing.

Error Messages Problem Possible Causes Service Check Remedy

ER1 • Fill valve on for over 6 min. (This occurs during initial fill on some units – see Initial Start-up.)

  • Check system for water leaks.
  • Correct any leaks and reset controller.

ER2 • Thermistor failure or loose connections in thermistor circuit.

  • Ensure that connector is securely attached to controller and that
  • Secure connections and reset controller. If error reoccurs, replace thermistor.

thermistor is securely connected.

ER3 • Thermistor is reading out of range.

  • Check tank temperature.
  • Replace thermistor.
  • ER4
  • No heat is detected
  • See Heating Problems
  • See Heating Problems

Filling Problems Problem Possible Causes Service Check Remedy

Overfilling water tank when power is Off

  • Fill valve not sealing properly.
  • Check to see if water enters tank continuously (usually at a slow rate).
  • Disassemble valve and clean out debris. Valve may need to be replaced.

Overfilling water tank only when power is On

  • High electrode coated with lime or faulty.
  • Disconnect electrode wire at quick connect (brown wire). Connect a wire from the quick connect to the cabinet body. If filling stops, this is the error cause.
  • Remove electrode assembly and clean the probes. If problem is not corrected, replace electrode assembly.
  • Connection from control board to tank body faulty.
  • Check to ensure connection (red wire) is secure.
  • Make connection to tank secure.
  • Control board is faulty.
  • Secure connection from control board to metal enclosure does not stop filling.
  • Replace control board.
Page 21 of the Grindmaster APBIC-430V2E230 user manual — Troubleshooting (cont.)
Page 21 · click to enlarge
Page 21

Troubleshooting (cont.)

Filling Problems Problem Possible Causes Service Check Remedy

Tank does not refill • No electrical power to equipment

  • Check for proper voltage at terminal block. Check circuit breaker on supply circuit.
  • Establish electrical power to unit.
  • No water supplied to equipment
  • Disconnect water supply line and ensure that water is provided to unit. Check to see that any and all valves in water line are open.
  • Establish water supply to unit.
  • No power to control board
  • Check for proper voltage across transformer primary terminals by disconnecting terminals. See wiring diagram for more information.
  • If there is not 120V across primary, proceed to step entitled “No power to control board and transformer not powered.” If there is proper voltage across primary, proceed to step entitled “No power to control board and transformer powered”.
  • No power to control board and transformer not powered.
  • Ensure there is proper voltage across terminal block. Check wiring diagram for more information.
  • Secure connections and reset circuit breaker on equipment.
  • No power to control board and transformer powered.
  • Disconnect quick disconnect on secondary side of transformer at quick disconnect between yellow and blue wires. Check for 24 Vac between blue and yellow wires.
  • If there is not 24 Vac between the blue and yellow wires, replace transformer. If proper voltage exists, secure connection between 3 pin connector and control board.
Page 22 of the Grindmaster APBIC-430V2E230 user manual — Heating Problems Problem Possible Causes Service Check Remedy
Page 22 · click to enlarge
Page 22

Troubleshooting (cont.)

Filling Problems Problem Possible Causes Service Check Remedy

Tank does not refill • Fill valve or control board is faulty

  • Check to ensure proper connection between 6 pin connector and control board. Check for proper connections at fill valve terminals. Drain 1 gal. (3.8L) of water from hot water faucet. Check for 24 Vac across fill valve
  • If 6 pin connector is securely attached to control board and all connections are secure and there is 24 Vac across fill valve terminals, replace fill valve.

terminals.

Heating Problems Problem Possible Causes Service Check Remedy

Tank does not heat • No electrical power to equipment

  • Check for proper voltage at terminal block. Check circuit breaker on supply circuit.
  • Establish electrical power to unit.
  • No power to control board
  • Check for proper voltage across transformer primary terminals by disconnecting terminals. See wiring diagram for more information.
  • If there is not proper voltage across primary, proceed to step entitled “No power to control board and transformer not powered” . If there is proper voltage across primary, proceed to step entitled “No power to control board and transformer powered”.
Page 23 of the Grindmaster APBIC-430V2E230 user manual — Troubleshooting (cont.)
Page 23 · click to enlarge
Page 23

Troubleshooting (cont.)

Heating Problems Problem Possible Causes Service Check Remedy

Tank does not heat • Low (long) electrode coated with lime or faulty.

  • Disconnect electrode wire at quick connect (purple wire). Connect a wire from the quick connect to the cabinet body. If heating begins, this is the error cause.
  • Remove electrode assembly and clean the probes. If problem is not corrected, replace electrode assembly.
  • Connection from control board to tank body faulty.
  • Check to ensure connection (green wire) is secure.
  • Make connection to tank secure.
  • Connections from control board to heater relay faulty.
  • Check to ensure connections (gray and blue wires) are secure.
  • Make connections to relay secure.
  • Line voltage connections to heater relay faulty.
  • Check to ensure connections (black and brown wires) are secure.
  • Make connections to relay secure.
  • Connections to remainder of heater circuit faulty.
  • Check to ensure connections from relay to thermal cut-out and from thermal cut-out to contactor and from contactor to proper terminal of terminal block are secure. See wiring diagram for more infomation.
  • Make connections secure.
  • Heater relay faulty.
  • Ensure that coil on heater relay is energized by ensuring that there is 24 VDC between the gray and blue wires attached to the relay. Remove the black and brown wires from the relay and check for an open circuit across the connection tabs (COM and NO) to which the wires were attached.
  • If the relay coil is energized and there is an open circuit across the connection tabs, replace relay.
  • Check for open circuit on thermal cut-out. (NOTE: Tripping of thermal cut-out can indicate presence of another problem with the unit. Unit should be monitored)
  • Replace thermal cut-out.
  • Thermal cut-out tripped or faulty.
Page 24 of the Grindmaster APBIC-430V2E230 user manual — Brew volume too large or too small
Page 24 · click to enlarge
Page 24

Troubleshooting (cont.)

Heating Problems Problem Possible Causes Service Check Remedy

Tank does not heat • Contactor faulty.

  • Ensure that coil on contactor is energized by ensuring that there is proper voltage between the brown and white wires attached to the relay. Check each side of the contactor (Line and Load) at each pole for continuity.
  • If the contactor coil is energized and there is an open circuit across any of the contactor poles, replace contactor.
  • Heater faulty.
  • Check resistance across element(s) with power conductors disconnected.
  • If resistance is much less than 8 Ohms or much more than 15 Ohms, replace heater(s).
  • Control board is faulty.
  • Check to ensure proper connection between connector 5-pin and control board. Check for proper connections in all heater control circuitry. Check for proper connections between N terminal of contactor coil and terminal block.
  • If 5-pin connector is securely attached to control board and all connections are secure and functioning except there is not 120 Vac across contactor coil terminals, replace control board.

Brewing Problems Problem Possible Causes Service Check Remedy

Brew volume too large or too small

  • Portion selected on touchpad not correct.
  • Review timer settings versus portion size.
  • Adjust timer to desired value or select different portion size.
  • Timer not set properly.
  • Compare timer setting to either factory setting or initial user setting to determine if it has been changed.
  • Adjust timer to desired value.
Page 25 of the Grindmaster APBIC-430V2E230 user manual — Brew cycle will not start
Page 25 · click to enlarge
Page 25

Troubleshooting (cont.)

Brewing Problems Problem Possible Causes Service Check Remedy

Brew volume too large or too small

  • Sprayhead clogged.
  • Visually check for clogging of holes in brewhead.
  • Clean all holes.
  • Brew valves clogged with lime deposits.
  • Visually inspect brew valve at hose connections.
  • Clean lime from valve. Seat, cup or entire valve may need replacement.
  • Water supply pressure or flow rate not adequate.
  • Check to see that fill valve cycles on and off frequently during brew cycle when all brew heads are used simultaneously. Check to ensure that water supply line is 3/8” and pressure is between 30 and 80 psi (207 and 552 KPA).
  • Supply water at adequate pressure and flow rate.

Brew volume erratic

  • Water supply pressure fluctuates.
  • Check water pressure with and without other appliances operating.
  • Plumb water supply so that water pressure is not significantly affected by other appliances.

Brew cycle will not start

  • Optional momentary switch to indicate container in place not engaged or faulty.
  • Check to see that container fully engages switch. Check for continuity across switch when switch is engaged.
  • If fully engaged switch does not complete circuit across terminals of switch, replace switch.
  • Brew circuit connections not secure.
  • Check to see that connector (6-pin) is securely connected to control board. Check to see that all connections from controller through brew valve are secure.
  • Secure connections.
  • If there is 24 Vac across terminals and brew valve is not open, replace valve.
  • Brew valve faulty.
  • Check to see if there is 24 Vac across brew valve terminals.
  • Touchpad faulty.
  • Check to see that touchpad connections to control board are secure.
  • If connections are secure, other functions appear normal and touchpad will not initiate a brew cycle, replace touchpad.
Page 26 of the Grindmaster APBIC-430V2E230 user manual — A530-066 Control Board used on all PrecisionBrew™ V2.0 models
Page 26 · click to enlarge
Page 26

Troubleshooting (cont.)

Brewing Problems Problem Possible Causes Service Check Remedy

Brew cycle will not start

  • Controller faulty.
  • Check to see that the power is supplied to the controller by following instructions given in the Troubleshooting section on Filling Problems. Once touchpad and momentary switch integrity is assured (see above), initiate a brew cycle and check for 24 Vac across brew valve.
  • If there is not 24 Vac across brew valve, replace control board.

Sprayhead will not stop dripping water

  • Brew valve not closing completely.
  • Visually inspect brew valve at hose connections.
  • Clean lime from valve. Seat, cup or entire valve may need replacement.
  • Water in tank boiling.
  • Remove sprayhead and determine if drip is coming from overflow.
  • Reduce tank temperature.

If you still need help, call our Service Department at (800) 695-4500 (USA and Canada only) or (502) 425-4776 (Monday-Friday 8:00 am - 6:00 pm EST) or an authorized service center in your area. Please have the model and serial number ready so that accurate information can be given.

Prior authorization must be obtained from Grindmaster-Cecilware’s Technical Services Department for all warranty claims.

A530-066 Control Board used on all PrecisionBrew™ V2.0 models

Refers to software version number. Subject to change.

Grindmaster APBIC-430V2E230 — A530-066 Control Board used on all PrecisionBrew™ V2.0 models diagram (page 26)
Fig. 4 · A530-066 Control Board used on all PrecisionBrew™ V2…
Page 27 of the Grindmaster APBIC-430V2E230 user manual — ITEM DESCRIPTION PART #
Page 27 · click to enlarge
Page 27

Parts List for All Precision Brew Models Models APB-330V2, APB-430V2, APBVSA-330V2, APBVSA-430V2, APBIC-330V2, APBIC-430V2

ITEM DESCRIPTION PART #

Reference Front View Picture:

1 Controller PB A530-066 2 Relay, Heater* A71450 3 Water Inlet Valve 24 VAC A725-117 4 Terminal Block A531-035 5 Spray Head APT400-105 6 Orifice Bypass A518-053 6A Retaining Pin for A518-053 A551-098 8 Switch Momentary ** PBIC only A531-025

Reference Lower Warmer Picture:

20 Faucet Hot Water A537-043 21 Light Warmer A515016 22 Switch Warmer A531-026 23 Heater Warmer 120V 100W A535-018 23 Heater Warmer 220V 100W A535-079 (for E230 models)

Reference Top View Picture:

30 Thermostat, Hi Limit A536-023 31 Contactor 4-Pole (120VAC coil)** A514005 (for models with 3 heaters) 31 Contactor 2-Pole (120VAC coil)** A515027 31 Contactor for 2-Pole E230V models A531-083 (230VAC coil) 31 Contactor for 4-Pole E230V models A531-076 (230VAC coil) 32 Transformer, 120/208/240 100W A554-137 33 Valve, Brew 24VAC PB A537-184V 34 Valve, Bypass 24VAC PB A537-183V 35 Solenoid, Basket Lock 24vdc A554-135 36 Touchpad PB Series A530-065 37 N/A N/A 38 Spray Elbow A518-054 39 Tee Barbed 3/8" KYNAR A548-172 40 Hose Overflow A585-016 41 Hose Silicone A512012 42 Elbow Silicone A548-129

Reference Tank Lid Picture:

50 Element Ht 5kW 240V (PB, PBVS) A535-010 (for models with 3 heaters) 50 Element Ht 5kW 240V (PBIC) A535-072 (for models with 3 heaters) 50 Element Htr 6.6kW 240V ** (PB, PBVSA) A535-059 50 Element Htr 6.6kW 240V ** (PBIC) A535-071 50 Element Htr 3.7kW 240V ** (PB, PBVSA) A535-068 (for models with 3 heaters) 50 Element Htr 3.7kW 240V ** (PBIC) A535-073 (for models with 3 heaters) 51 Thermistor A536-027 52 Electrode Assembly A712-018 53 Gasket Tank ** A544-029

* A531-072 = 12VDC coil; A71450 = 24VDC coil ** part not shown

Page 28 of the Grindmaster APBIC-430V2E230 user manual — Lower Warmer (refer to key on page 27) (APB-430V2 pictured)
Page 28 · click to enlarge
Page 28

Front View (refer to key on page 27)

Grindmaster APBIC-430V2E230 — Front View (refer to key on page 27) diagram (page 28)
Fig. 5 · Front View (refer to key on page 27)

Lower Warmer (refer to key on page 27) (APB-430V2 pictured)

Grindmaster APBIC-430V2E230 — Lower Warmer (refer to key on page 27) (APB-430V2 pictured) diagram (page 28)
Fig. 6 · Lower Warmer (refer to key on page 27) (APB-430V2 pi…

1*

Page 29 of the Grindmaster APBIC-430V2E230 user manual — Tank Lid (refer to key on page 27) 3 Heater Model shown
Page 29 · click to enlarge
Page 29

Top View (refer to key on page 27)

36 35 38 35

Grindmaster APBIC-430V2E230 — Top View (refer to key on page 27) diagram (page 29)
Fig. 7 · Top View (refer to key on page 27)

Tank Lid (refer to key on page 27) 3 Heater Model shown

Grindmaster APBIC-430V2E230 — Tank Lid (refer to key on page 27) 3 Heater Model shown diagram (page 29)
Fig. 8 · Tank Lid (refer to key on page 27) 3 Heater Model sh…
Page 30 of the Grindmaster APBIC-430V2E230 user manual — Upper Faucet (Part # A537-049)
Page 30 · click to enlarge
Page 30

Shuttle Parts List for APB-330V2 and APB-430V2

Grindmaster APBIC-430V2E230 — Shuttle Parts List for APB-330V2 and APB-430V2 diagram (page 30)
Fig. 9 · Shuttle Parts List for APB-330V2 and APB-430V2

ITEM DESCRIPTION PART #

1 Faucet Model ES A537-053

2 Shank w/ Chrome Bonnet A522078

3 Gauge Assembly A718-018

4 Kit, Shuttle Lid A725-092

S.S. Shuttle Cover (not shown)* A713-027

5 Lid Retaining Clip A548-142

6 Lid Stopper w/ O-Ring A548-140 A61365

* S.S. Cover used until August 2001

A318-119P Top Gage Fitting

A522026 Washer Upper Gage

A522102 Silicone Seat Cup

A522027 Washer Lower Gage

Upper Faucet (Part # A537-049)

Gauge Assembly (Part # A718-018)

Show 7 more labels / short text on this page
A537-055 Handle · A555-001 Gage Shield · A522132 Bonnet Nut · A522120 Spring · A522031 Gage Glass · A537-047 Plastic Stem · AA-958 Gage Base
Page 31 of the Grindmaster APBIC-430V2E230 user manual — VS-1.5S VS-S
Page 31 · click to enlarge
Page 31

Model VS-1.5 Vacuum Shuttle Parts List

ITEM NO. Title PART NUMBER VS-S/QTY.

1 Stand Body A548-157 1 2 Tray for Stand A548-159 1 3 Stand Base A548-158 1 4 Tray Top A517-018 1 5 Stand, Top Plate A517-019 1 6 NUT M4 W Nylon Insert A540-237 4 7 Self-Tapping Screw .5" A539-217 4 8 Rubber Foot A548-161 4

VS-1.5S VS-S

ITEM NO. Title PART NUMBER VS-1.5S/QTY.

1 Stand Body A548-157 1 2 Tray for Stand A548-159 1 3 Vacuum Shuttle VS-1.5 1 4 Stand Base A548-158 1 5 Tray Top A517-018 1 6 Self-Tapping Screw .5" A539-217 4 7 Rubber Foot A548-161 4 8 Plastic Insert A548-162 3 9 Self-Tapping Scres .75" A539-218 3

Page 32 of the Grindmaster APBIC-430V2E230 user manual — Cleaning & Sanitizing Instructions for Model VS-1.5(S)
Page 32 · click to enlarge
Page 32

Cleaning & Sanitizing Instructions for Model VS-1.5(S)

These cleaning and sanitizing instructions are only a guideline to be used for the cleaning and sanitizing of the VS-1.5S and VS-S with VS-1.5. In-house cleaning and sanitizing methods may be more effective. Grindmaster assumes no responsibility for the food born illness and/or sickness caused by using improper sanitizing methods.

For cleaning and sanitizing of the VS-1.5S and VS-S with VS-1.5 the three-sink method is recommended. The three- sink method consists of the sink full of hot soapy water using an approved detergent, a fresh water rinse, and an aqueous sanitizing solution using an approved iodine sanitizer with mixture between 12.5-25 PPM.

1. Rinsing the unit after use: a) Rinse unit with hot water and empty completely. b) Fill unit with hot water. c) Open unit and empty contents completely by opening the faucet completely.
2. Cleaning and sanitizing lid assembly: a) Remove lid from unit, fully submerse it in cleaning solution. Using a clean cloth, wipe the unit thoroughly. b) Using supplied brush, clean mixing tube thoroughly. c) Rinse with clean water. d) Submerse in sanitizing solution for 5 minutes then air dry completely.
3. Cleaning and sanitizing body assembly: a) Remove unit from the base. (only when using VS-S with VS-1.5) b) Completely fill the unit with cleaning solution. Using a clean cloth, wipe the unit thoroughly. c) Rinse unit thoroughly with fresh water. d) Remove faucet, shank, and sight gauge from unit and place in cleaning solution. e) Open lid on the bottom of the unit and remove silicon tube (Tank to Faucet Tube) and place in cleaning

solution for cleaning. f) Reassemble unit. g) Fully fill unit with sanitizing solution for 5 minutes and drain through fully opened faucet. h) Wipe outside of the unit with a clean cloth moistened with sanitizing solution. i) Place unit on rack upside down to thoroughly air-dry.

4. Cleaning Stand Assembly and tray: a) Remove tray and tray top and place in cleaning solution. Using a clean cloth, clean tray and tray

top thoroughly. b) Wipe outside of the stand with a clean cloth moistened with sanitizing solution. c) Place parts on rack to thoroughly air-dry.

5. Cleaning the Faucet assembly and silicone tube: a) Using supplied brush, clean silicone tube, sight gauge tube, and shank assembly. b) Rinse parts and place in sanitizing solution for 5 minutes, remove and air dry. c) Remove top from faucet and use brush to clean inside, rinse and place in sanitizing solution for 5 minutes.

Remove and air dry.

6. When all pieces are completely dry reassemble for use.
Page 33 of the Grindmaster APBIC-430V2E230 user manual — Wiring Diagram - Precision Brew 430 Series Models APB-430V2, APBVSA-430V2, and APBIC-430V2
Page 33 · click to enlarge
Page 33

Wiring Diagram - Precision Brew 430 Series Models APB-430V2, APBVSA-430V2, and APBIC-430V2

Grindmaster APBIC-430V2E230 — Wiring Diagram - Precision Brew 430 Series Models APB-430V2, APBVSA-430V2, and APBIC-430V2 diagram (page 33)
Fig. 10 · Wiring Diagram - Precision Brew 430 Series Models AP…
Page 34 of the Grindmaster APBIC-430V2E230 user manual — Wiring Diagram - Precision Brew 330 Series Models APB-330V2, APBVSA-330V2, and APBIC-330V2
Page 34 · click to enlarge
Page 34

Wiring Diagram - Precision Brew 330 Series Models APB-330V2, APBVSA-330V2, and APBIC-330V2

Grindmaster APBIC-430V2E230 — Wiring Diagram - Precision Brew 330 Series Models APB-330V2, APBVSA-330V2, and APBIC-330V2 diagram (page 34)
Fig. 11 · Wiring Diagram - Precision Brew 330 Series Models AP…
Page 35 of the Grindmaster APBIC-430V2E230 user manual — Wiring Diagram APB-430V2E230, APBVSA-430V2E230, APBIC-430V2E230 (Single or Three Phase Models)
Page 35 · click to enlarge
Page 35

Wiring Diagram APB-430V2E230, APBVSA-430V2E230, APBIC-430V2E230 (Single or Three Phase Models)

Grindmaster APBIC-430V2E230 — Wiring Diagram APB-430V2E230, APBVSA-430V2E230, APBIC-430V2E230 (Single or Three Phase Models) diagram (page 35)
Fig. 12 · Wiring Diagram APB-430V2E230, APBVSA-430V2E230, APBI…
Page 36 of the Grindmaster APBIC-430V2E230 user manual — Wiring Diagram APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230 Brewers
Page 36 · click to enlarge
Page 36

Wiring Diagram APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230 Brewers

Grindmaster APBIC-430V2E230 — Wiring Diagram APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230 Brewers diagram (page 36)
Fig. 13 · Wiring Diagram APB-330V2E230, APBVSA-330V2E230, APBI…
Page 37 of the Grindmaster APBIC-430V2E230 user manual — YGF
Page 37 · click to enlarge
Page 37

Wiring Diagram - Precision Brew 430 Series 120/208 or 120/240V Models APB-430V2, APBVSA-430V2, and APBIC-430V2

:+7

%/.

9:505(/(07

%/.

%/. %/.

32:(5 0$67(5 237,21$/

7(50,1$/ %/2&.

:$50(5

:+7 6:,7&+

:$50(5/,*+7

:+7

32:(5 6833/

9:505(/(07

%/.

%/. %/.

6:,7&+ :$50(5

:$50(5/,*+7

:+7

:+7

:+7

%/.

6((:$50(5 &,5&8,7',$*

:+7

%51 Wƒ

%/.

%/.

9$&

:+7

:+7

9$/9(YDF :$7(5,1/(7

%5(:9$/9(/()7YDF

%5(:9$/9(5,*+7YDF

:$7(5

:$7(57$1.

%<3$669$/9(5,*+7YDF *5281' $ &21752//(5

/()76+877/(6:,7&+

5,*+76+877/(6:,7&+ 7+(50,6725 352%(

5,*+7%$6./2&.62/

/()7%$6./2&.62/

YGF

YGF

Show 35 more labels / short text on this page
/ · / · 3%02'(/6 · 6((+($7(5&21),*62127+(56+((7 · / · &217$&725 / / · 1 / / · / · / · %51 · 9 · +,7(03/,0,7 7+(50267$7 · %51 · 9$ · 75$16)250(5 · 25* · &20 · %/8 · · 9$& · &20 · · 5(' · %/8( · %/8 · - · 352%(6 · %<3$669$/9(/()79$& · - · - · +($7(5 · - · ,%&4ġ4/5#(0!$ · 2)'(4ġ4/5#(0!$ · +($7(55(/$<
Page 38 of the Grindmaster APBIC-430V2E230 user manual — YGF
Page 38 · click to enlarge
Page 38

Wiring Diagram - Precision Brew 330 Series 120/208V, 120/240V Models APB-330V2, APBVSA-330V2, and APBIC-330V2

:+7

%/.

32:(5 0$67(5 237,21$/

7(50,1$/%/2&.

32:(5 6833/

7$1.+($7(5

%/.

6((:$50(5 &,5&8,7',$*

:+7

%51 :+7

9:505(/(07

%/.

%/. %/.

%51 Wƒ

:$50(5

:$50(5/,*+7

6:,7&+

:+7

:+7

%/.

%/.

9$&

:+7

:+7

9$/9(YDF :$7(5,1/(7

%<3$669$/9(YDF

%5(:9$/9(YDF

:$7(57$1.

:$7(5

6+877/(6:,7&+ 7+(50,6725 352%(

%$6./2&.62/

YGF

4/5#(0!$

Show 31 more labels / short text on this page
/ · / · &217$&725 · / · 1 / / · / · 9 · 3%02'(/6 · +,7(03/,0,7 7+(50267$7 · / · %51 · 9$ · 75$16)250(5 · 25* · &20 · %/8 · · 9$& · &20 · · 5(' · %/8( · %/8 · - · 352%(6 · - · *5281' $ &21752//(5 · - · +($7(5 · - · +($7(55(/$<
Page 39 of the Grindmaster APBIC-430V2E230 user manual — YGF
Page 39 · click to enlarge
Page 39

Wiring Diagram

230V, 208V, or 240V without Neutral

Models APB-430V2, APBVSA-430V2, APBIC-430V2, APB-430V2E230, APBVSA-430V2E230,

:+7

%/.

259:505(/(07

32:(5 0$67(5 237,21$/

%/.

%/. %/.

7(50,1$/%/2&.

:$50(5

6:,7&+

:$50(5/,*+7

:+7

:+7

32:(5 6833/

259:505(/(07

%/.

%/. %/.

6:,7&+ :$50(5

:$50(5/,*+7

:+7

:+7

%/.

6((:$50(5 &,5&8,7',$*

:+7

:+7

+,7(03/,0,7 7+(50267$7 %51 Wƒ

RU 75$16)250(5

%/.

%/.

&20 :+7

9$&

:+7

9$/9(YDF :$7(5,1/(7

%5(:9$/9(/()7YDF

%5(:9$/9(5,*+7YDF

:$7(57$1.

%<3$669$/9(5,*+7YDF *5281' $ &21752//(5

:$7(5

/()76+877/(6:,7&+

5,*+76+877/(6:,7&+ 7+(50,6725 352%(

5,*+7%$6./2&.62/

/()7%$6./2&.62/

YGF

YGF

Show 35 more labels / short text on this page
and APBIC-430V2E230 · / · / · 3%02'(/6 · / · 6((+($7(5&21),*62127+(56+((7 · &217$&725 / / · 1 / / · / · / · / · 9 · 9 %51 · %51 · 9$ · 25* · &211(&7$335235,$7(/<)2592/7$*(6833/< · · %/8 · 9$& · &20 · · 5(' · %/8( · %/8 · - · 352%(6 · %<3$669$/9(/()79$& · - · - · +($7(5 · - · ,%&4ġ4/5#(0!$ · 2)'(4ġ4/5#(0!$ · +($7(55(/$<
Page 40 of the Grindmaster APBIC-430V2E230 user manual — YGF
Page 40 · click to enlarge
Page 40

Wiring Diagram

230V, 208V, or 240V without Neutral Models APB-330V2, APBVSA-330V2, APBIC-330V2, APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230

:+7

%/.

32:(5 0$67(5 237,21$/

7(50,1$/%/2&.

32:(5 6833/

7$1.+($7(5

%/.

6((:$50(5 &,5&8,7',$*

:+7

9 %51 :+7

259:505(/(07

:$50(5 %/.

%/. %/.

%51 Wƒ

:$50(5/,*+7

:+7

6:,7&+

:+7

RU 75$16)250(5

%/.

%/.

&20 :+7

9$&

:+7

9$/9(YDF :$7(5,1/(7

%<3$669$/9(YDF

%5(:9$/9(YDF

:$7(57$1.

:$7(5

6+877/(6:,7&+ 7+(50,6725 352%(

%$6./2&.62/

YGF

4/5#(0!$

Show 31 more labels / short text on this page
/ · / · &217$&725 · / · 1 / / · / · 9 · 3%02'(/6 · +,7(03/,0,7 7+(50267$7 · / · %51 · / · 9$ · 25* · &211(&7$335235,$7(/<)2592/7$*(6833/< · · %/8 · 9$& · &20 · · 5(' · %/8( · %/8 · - · 352%(6 · - · *5281' $ &21752//(5 · - · +($7(5 · - · +($7(55(/$<
Page 41 of the Grindmaster APBIC-430V2E230 user manual — Wiring Diagram - Heater Configuration (3 Heater)
Page 41 · click to enlarge
Page 41

Wiring Diagram - Heater Configuration (3 Heater)

Page 42 of the Grindmaster APBIC-430V2E230 user manual — Wiring Diagram - Heater Configuration (1 Heater)
Page 42 · click to enlarge
Page 42

Wiring Diagram - Heater Configuration (1 Heater)

Page 43 of the Grindmaster APBIC-430V2E230 user manual — Control Board all PrecisionBrew™ V2.0 models
Page 43 · click to enlarge
Page 43

Control Board all PrecisionBrew™ V2.0 models

Refers to software version number.

Subject to change.

Grindmaster APBIC-430V2E230 — Control Board all PrecisionBrew™ V2.0 models diagram (page 43)
Fig. 14 · Control Board all PrecisionBrew™ V2.0 models
Page 44 of the Grindmaster APBIC-430V2E230 user manual — Programming Sequence for Medium Portions (cont.)
Page 44 · click to enlarge
Page 44
  • Tel (502) 425-4776
  • Fax (502) 425-4664
  • 1-800-695-4500 (USA & Canada only)
  • P.O. Box 35020
  • Louisville, KY 40232
  • USA <a href="http://www.grindmaster.com" rel="nofollow noopener" target="_blank">www.grindmaster.com</a>
  • email: info@<a href="http://grindmaster.com" rel="nofollow noopener" target="_blank">grindmaster.com</a> © Grindmaster Corporation, 2011 PRINTED IN USA

0611 Form # AM-346-03 Part # A090-842

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Overfilling water tank when power is Off p.20
Overfilling water tank only when power is On p.20
Tank does not refill p.21
Tank does not heat p.22
Brew volume too large or too small p.24
Brew volume erratic p.25
Brew volume erratic p.25
Brew cycle will not start p.25
Sprayhead will not stop dripping water p.26

Ask about the Grindmaster APBIC-430V2E230

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Grindmaster APBIC-430V2E230

Be the first to ask — other owners or our team will answer.

Original document

Grindmaster APBIC-430V2E230 manual PDF

44 pages·1.7 MB·Coffeemaker·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…