The following warning labels were on your dispenser when it was shipped from the factory. They should remain on your dispenser in good, readable condition at all times. If one of your labels is missing or damaged, order a replacement label immediately.
Part # A546-445 Located on front splash panel and lid of machine.

Located on APB-330V2, APB-330V2E230, APB-430V2, and APB-430V2E230 lower front decal. Order part # A546-434 for APB-330V2. Order part # A546-435 for APB-430V2.
Located on APBIC-330V2, APBIC-330V2E230, APBIC-430V2, and APBIC-430V2E230 above faucet. Order part # A546-428 for APBIC-330V2. Order part # A546-427 for APBIC-430V2.
Part # A71949 Located on brew baskets.


WARNING
Installation of this appliance should be performed by qualified service personnel only. Improper installation could result in electrocution.
The electric and water hook-up locations are behind the front panel. Remove the four screws fastening this panel for access to these connections.

The brewer is designed to operate at the specified voltage on the nameplate with a tolerance of ± 10% for voltage deviation. It is very important that the power line to the brewer be checked to make sure that the voltage is within 10% of the brewer’s rated voltage. Failure to provide adequate voltage, as defined above, will cause problems with your brewer. If the power is too low, the solenoid valves may or may not work or longer recovery time will be experienced. The brewer may be permanently damaged if the voltage is too high.
4) Standard connection is 1 phase 3 wire. Connect the two lines to L1 and L2 on the terminal block. If the brewer is wired for three phase, a lug, L3, is provided on the terminal block. Neutral line should be connected to the N terminal. Alternately, if no neutral is available, the brewer can be wired accordingly by connecting L1 to position marked “L1” and L2 to position marked “L2”. This will require the installer to change the connection to the transformer primary from the white wire (120V) to the blue (208V) or orange (230,240V) connection. See below. NOTE: This “no neutral” conversion is only applicable to units marked as 208V, 230V, or 240V. It is NOT applicable to units marked 120/208V or 120/240V.
Note: The brewer utilizes a multiple tap primary transformer to convert line voltage to 24 volts for use by the controller and some operating controls. The transformer has taps for 120V (white wire), 208V (blue wire), and 240V (orange wire) line voltage. Be sure to connect the white wire from the terminal block to the proper tap for the supplied voltage. See diagram below.
ORANGE
TO CONTROLLER
RED
TRANSFORMER
208V BLUE
WHITE FROM TERMINAL BLOCK *N-120V *L2 -208V or 230V
120V WHITE
FROM L1 BLACK
Never use the ground conductor as a neutral. This could cause electrocution.

CAUTION
Water used for brewing coffee is very hot. Use caution when brewing, pouring, or transporting coffee. Accidental spills may result in severe burns.
Coffee basket contains very hot water until the drip is completed. Early removal of a dripping basket could result in burns.

All adjustments to machine are accessible through the front display(s). Refer to specifics below and the Programming Routine section. All values are preset at the factory and may vary brewer to brewer.
Temperature Adjustment Tank temperature can be adjusted from 170°F – 205°F (77°C – 96°C) through the front display. See Programming Routine section for procedure.
This brewer can be set for maximum water temperature of 205°F (96°C). The boiling point of water is lower as altitude increases. The setpoint temperature of the brewer should be maintained below the boiling point at a given elevation. Refer the to the chart below for recommended maximum setpoint for given altitudes.


Brew Volume “br” Brew time can be set for each size visually. See Setting Brew Volume Procedure below. Brew time can also be adjusted through the display. See Programming Routine section.
Setting Brew Volume Visually 1. Remove brew basket and place container under brew head. 2. Press and hold desired brew button for 5 seconds. Display will read “Pro”. 3. Within 20 seconds, press and release desired brew button. Water will dispense from spray head and time will count-up in display. 4. When volume is at desired amount, press and release brew button to stop flow. Time will flash in display. 5. Within 20 seconds, press and release desired brew button. Display will clear and brew time will be stored into memory. Note: During this routine, no pulsing or bypass will occur. Note: If the On/Off button is pressed during procedure, time setting will default to previous time.
Pre-infusion: Controls the initial coffee grounds wetting and the first dwell time after the initial wetting. Pulse brews are the series of pulses after the Pre-infusion process. All pulse ON and OFF times are the same.
Brew Countdown Timer: After the start of a brew the LED display will countdown the remaining time left in the brew process. The countdown will include all OFF periods programmed in the Pre-infusion and the pulses. At the end of the brew time, the display will scroll driP, while the brew basket drains itself. At the end of the drip cycle, the display will scroll doneE for 30 seconds then turn off.
Energy Savings Mode: If enabled, when the brewer is idle for three (3) hours this feature will allow the water tank to lower its holding temperature to 120°F. The display will scroll SLEEPIng while in this mode.
Copy-to-Left: On twin brewers, this feature allows you to copy the brew parameters programmed on a particular brew portion on the Right side to the Left side.
On twin brewers, the right side, Large portion button gives the user access to the global programming parameters of the brewer, such as; Tank Temperature, Energy Savings Mode, Enable/Disable Low Temp No Brew, ON/OFF, Drip Time and Bypass Ratio. After the global parameters are set, the individual portion brew parameters can be set. All other portion sizes (left and right) only access individual brew parameters to that particular portion. Also, on twin brewers, the last program step in programming individual brew parameters allows the operator to copy those brew parameters to the left side if “YES” is selected. If “YES” is selected, the brew parameters that were set for the right side for that particular portion are copied to the left side. If “NO” is selected, then the left side must be programmed separately.
Press the UP and DOWN arrows simultaneously for 5 seconds. Once in program mode, the green LED for each por- tions size will flash.

To program the following items, press the Large, Right side portion button. (refer to Table 1)
5) DriP time: Choose from 40% to 80% of brew time. This is the amount of time the brewer takes to completely drain the brew basket after the brew valve closes. The factory default is 50%, so if the brewer is set for a 1.5 gallon brew, without pre-infusion and pulses, the brew basket will remain locked for 2 minutes after the brew valve closes. If, with coffee, the brew basket drips for longer than 2 minutes, increase the setting to 60% which will be 2:24 of drip time. The setting increases by 5% increments; 12 seconds each.
Bypass ratio is the last global program parameter to be set. The following are the individual brew portion parameters. Each portion button can have individual brew sequences.

The sequence of programming for the Medium portion is as follows: (refer to Table 2)
The sequence of programming for the Small portion is as follows: (refer to Table 3)

OG G O S S
PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. DISPLAY WILL READ AS FOLLOWS:
READING
ADJUST
ADVANCE
OR
TEMP SCALE
TANK TEMP (170-202F) OR
ENERGY MODE
ENERGY MODE
OR
LOW-TEMP/NO-BREW
LOW-TEMP/
OR
NO-BREW
DRIP TIME
DRIP TIME PERCENT OF BREW
TO
BYPASS RATIO
OR
BREW TIME
BREW TIME (.01 TO 6.00)
PRE INFUSION
PRE INFUSION TIME (OFF TO 2.00) TO
continued on next page

READING DISPLAY
ADJUST
ADVANCE
PRE INFUSION
PRE INFUSION OFF TIME TO
(.05 TO 2.00)
PULSE BREW
# OF PULSES
TO
(OFF, 1 - 10)
PULSE ON
PULSE ON TIME (0:05-2:00)
PULSE OFF
PULSE OFF TIME (0:05-2:00)
BY-PASS
OFF TO .25 PERCENT
TO
COPY TO LEFT
OR

OG G O S S
PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS.
READING DISPLAY
ADJUST
ADVANCE
BREW TIME
BREW TIME (.01 TO 6.00)
PRE INFUSION
PRE INFUSION TIME (OFF TO 2.00)
TO
PRE INFUSION
PRE INFUSION OFF TIME
TO
(.05 TO 2.00)
PULSE BREW
# OF PULSES
TO
(OFF, 1 - 10)
PULSE ON
PULSE ON TIME (0:05-2:00)
PULSE OFF
PULSE OFF TIME (0:05-2:00)
BY-PASS
OFF TO .25 PERCENT
TO
continued on next page

PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS.
DISPLAY
ADJUST READING ADVANCE
COPY TO LEFT
OR
· ·

OG G O S S
PRESS-AND-HOLD UP & DOWN ARROWS FOR 5 SECONDS. DISPLAY WILL READ AS FOLLOWS:
ADJUST READING
ADVANCE
BREW TIME
BREW TIME (.01 TO 6.00)
PRE INFUSION
PRE INFUSION TIME (OFF TO 2.00)
TO
PRE INFUSION
PRE INFUSION OFF TIME
TO
(.05 TO 2.00)
PULSE BREW
# OF PULSES
TO
(OFF, 1 - 10)
PULSE ON
PULSE ON TIME (0:05-2:00)
PULSE OFF
PULSE OFF TIME (0:05-2:00)
COPY TO LEFT
OR
·

WARNING
Hot liquids and surfaces are present in this equipment. To avoid burns use caution when cleaning. Rinse hot parts with cold water before cleaning. Use gloves or a heavy cloth when removing hot parts from brewer.
11) Fill Shuttles with one gallon, 2/3 full, of hot water.
12) Pour into the Shuttle liners the recommended concentration of urn cleaner (excessive amounts of cleaner will attack the stainless steel).
Urn cleaners that have been used successfully:
DIP-IT TABZ™ Super Concentrate manufactured by Reckitt Benckiser, Inc. manufactured by Urnex Brands, Inc. 1655 Valley Road 170 Ludlow Street Wayne, NJ 07474 Yonkers, NY 10705 (800) 228-4722 or (973) 633-3600 (800) 222-2826 or (914) 963-2042
13) Scrub the liner interior with a plastic bristle brush.
14) Remove the knurled nut at the top of the gauge glass and clean the glass with a small bottle brush.
15) Pour out the contents of the Shuttle.
16) Remove the handle assembly of the Shuttle faucet by unscrewing the plastic bonnet.
17) Gently wash the faucet seat cup with a soft cloth and warm soapy water.
18) Wash the faucet shank with a bottle brush.
19) Soak airpot pick-up tube assembly in hot soapy water. Urn cleaner may be used for stronger cleaning.1
Burn Hazard!

The rest of this manual contains information to aid the service person who is working on this equipment. This page has information on performing common service tasks. Following this is the Troubleshooting section which can help diagnose problems which are divided into three basic systems: filling, heating, and brewing.
Next is an illustrated parts breakdown which will help in the selection of repair parts. If further assistance is needed, call our Technical Service Department at 800-695-4500 (USA & Canada only) or (502) 425-4776 Monday – Friday between 8:00 am and 6:00 pm Eastern time.
Wiring diagrams are also provided. Locate the basic diagram for the model you are working with. If there are any options, see Diagram #091-548 (page 33 of this manual) which shows the wiring alterations for options.
Always empty the tank before shipping.
Draining of tank should be performed by a qualified service technician. The tank contains very hot water. May cause severe burns.

User Lockout is achieved via the position of the LOCK jumper on the board header. Locate the header on the board (shown below) and place the jumper in the desired position. In the Locked position all menus in this document are locked out, and the unit will only allow brewing functions. There are two versions of the header, 10 pin and 2 pin. Both configurations are shown below.
2 Pin Version
UNLOCKED
UNLOCKED
LOCK
LOCK
LOCKED
LOCKED
LOCK
LOCK
System Restore Function
This function will restore a Precision Brew® unit to its original factory settings. To activate system restore, power on the unit while holding in the DOWN button on the keypad (use the keypad that controls the RIGHT side for a double unit).
Continue holding the DOWN button and the display will scroll “rEStorE” to indicate that a system restore is about to happen. If the DOWN button is released at this point, the restore is cancelled. If the button hold is continued, the display will scroll “donE” to show completion of a system restore.
Upon a successful restore, the original factory settings will override all changes. The brew counters are not affected.
The following sections describe features that are not intended to be used by the end user. These features, instead, are intended to help Grindmaster set up and test the machine.
This menu is intended to check product functionality both at the end of the factory line and in the field. The con- trol must be completely OFF (both sides) to enter field test. This mode is entered by pressing and holding the UP key and the LARGE BREW key on the keypad (use the keypad that controls the RIGHT side for a double unit) for 6 seconds. Once the menu is entered, the unit will start with an LED test that lights all LEDs and segments on the display.
Proceeding through the field test is done by pressing the ON/OFF key (RIGHT side if a double unit). Each time this button is pressed, the test will advance to the next step. For the output test, use the UP and DOWN keys to select the desired output.
Refer to the table on the following page for operation. Field Test Mode exits after stepping through all modes only- there is not a timeout.

Step Function Operation Description
1 LED Test All LEDs ON Verify that all LEDs turn on.
2 Firmware Version Display firmware version Shows the software version of the control.
3 Date Code Not used Not used
4 EEPROM Version Not used Not used
5 Non Resetable Unit Counter
Scroll non-resetable unit counter Shows the total number of brews made by the brewer (both sides if a double unit)
6 Display Water Temperature
Show averaged A/D reading of temperature Shows the current temperature in °F of the
thermister.
7 Display Water Level 1 Show averaged A/D reading of water level 1 If > 500 water level is full,
If < 500 water level is not full.
8 Display Water Level 2 Show averaged A/D reading of water level 2 If > 500 water is at the heater level,
If < 500 water level not at the heater level.
9 Show Input Display scrolls “InPut” Input Test Mode
10 Input Test Press each key and the display will show a number related to that key
Right Side On/Off - 1 (advances test) Up - 5 Down - 3 Large Brew - 4 Medium Brew - 2 Small Brew - 0 Basket Switch - 17 Left Side On/Off - 9 Up - 13 Down - 11 Large Brew - 12 Medium Brew - 10 Small Brew - 8 Basket Switch - 16
11 Show Output Display scrolls “outPut” Output Test Mode
Scroll through relay outputs with the UP and DOWN keys.
12 Output Test Turns on each relay separately. Displays “O##“ where:
## = 2 digit output number
Outputs are as follows:
O01 - Fill Valve O02 - Right Bypass Valve O03 - Left Bypass Valve O04 - Right Brew Valve O05 - Left Brew Valve O06 - not used O07 - Tank Heater O08 - Right Basket Lock O09 - Left Basket Lock O10 - not used

The following pages are provided to help determine the cause of problems with operation of the brewers and to indicate the appropriate solution for the problems. For each problem, the possible causes should be checked in the order shown until the exact nature of the problem is determined.
The following procedures must be performed by a qualified service technician. Disconnect power to machine before servicing.
ER1 • Fill valve on for over 6 min. (This occurs during initial fill on some units – see Initial Start-up.)
ER2 • Thermistor failure or loose connections in thermistor circuit.
thermistor is securely connected.
ER3 • Thermistor is reading out of range.

Filling Problems Problem Possible Causes Service Check Remedy
Tank does not refill • No electrical power to equipment

Filling Problems Problem Possible Causes Service Check Remedy
Tank does not refill • Fill valve or control board is faulty
terminals.
Tank does not heat • No electrical power to equipment

Heating Problems Problem Possible Causes Service Check Remedy
Tank does not heat • Low (long) electrode coated with lime or faulty.

Heating Problems Problem Possible Causes Service Check Remedy
Tank does not heat • Contactor faulty.

Brewing Problems Problem Possible Causes Service Check Remedy

Brewing Problems Problem Possible Causes Service Check Remedy
If you still need help, call our Service Department at (800) 695-4500 (USA and Canada only) or (502) 425-4776 (Monday-Friday 8:00 am - 6:00 pm EST) or an authorized service center in your area. Please have the model and serial number ready so that accurate information can be given.
Prior authorization must be obtained from Grindmaster-Cecilware’s Technical Services Department for all warranty claims.
Refers to software version number. Subject to change.


Parts List for All Precision Brew Models Models APB-330V2, APB-430V2, APBVSA-330V2, APBVSA-430V2, APBIC-330V2, APBIC-430V2
Reference Front View Picture:
1 Controller PB A530-066 2 Relay, Heater* A71450 3 Water Inlet Valve 24 VAC A725-117 4 Terminal Block A531-035 5 Spray Head APT400-105 6 Orifice Bypass A518-053 6A Retaining Pin for A518-053 A551-098 8 Switch Momentary ** PBIC only A531-025
Reference Lower Warmer Picture:
20 Faucet Hot Water A537-043 21 Light Warmer A515016 22 Switch Warmer A531-026 23 Heater Warmer 120V 100W A535-018 23 Heater Warmer 220V 100W A535-079 (for E230 models)
Reference Top View Picture:
30 Thermostat, Hi Limit A536-023 31 Contactor 4-Pole (120VAC coil)** A514005 (for models with 3 heaters) 31 Contactor 2-Pole (120VAC coil)** A515027 31 Contactor for 2-Pole E230V models A531-083 (230VAC coil) 31 Contactor for 4-Pole E230V models A531-076 (230VAC coil) 32 Transformer, 120/208/240 100W A554-137 33 Valve, Brew 24VAC PB A537-184V 34 Valve, Bypass 24VAC PB A537-183V 35 Solenoid, Basket Lock 24vdc A554-135 36 Touchpad PB Series A530-065 37 N/A N/A 38 Spray Elbow A518-054 39 Tee Barbed 3/8" KYNAR A548-172 40 Hose Overflow A585-016 41 Hose Silicone A512012 42 Elbow Silicone A548-129
Reference Tank Lid Picture:
50 Element Ht 5kW 240V (PB, PBVS) A535-010 (for models with 3 heaters) 50 Element Ht 5kW 240V (PBIC) A535-072 (for models with 3 heaters) 50 Element Htr 6.6kW 240V ** (PB, PBVSA) A535-059 50 Element Htr 6.6kW 240V ** (PBIC) A535-071 50 Element Htr 3.7kW 240V ** (PB, PBVSA) A535-068 (for models with 3 heaters) 50 Element Htr 3.7kW 240V ** (PBIC) A535-073 (for models with 3 heaters) 51 Thermistor A536-027 52 Electrode Assembly A712-018 53 Gasket Tank ** A544-029
* A531-072 = 12VDC coil; A71450 = 24VDC coil ** part not shown



1*

36 35 38 35




1 Faucet Model ES A537-053
2 Shank w/ Chrome Bonnet A522078
3 Gauge Assembly A718-018
4 Kit, Shuttle Lid A725-092
S.S. Shuttle Cover (not shown)* A713-027
5 Lid Retaining Clip A548-142
6 Lid Stopper w/ O-Ring A548-140 A61365
* S.S. Cover used until August 2001
A318-119P Top Gage Fitting
A522026 Washer Upper Gage
A522102 Silicone Seat Cup
A522027 Washer Lower Gage
Gauge Assembly (Part # A718-018)

ITEM NO. Title PART NUMBER VS-S/QTY.
1 Stand Body A548-157 1 2 Tray for Stand A548-159 1 3 Stand Base A548-158 1 4 Tray Top A517-018 1 5 Stand, Top Plate A517-019 1 6 NUT M4 W Nylon Insert A540-237 4 7 Self-Tapping Screw .5" A539-217 4 8 Rubber Foot A548-161 4
ITEM NO. Title PART NUMBER VS-1.5S/QTY.
1 Stand Body A548-157 1 2 Tray for Stand A548-159 1 3 Vacuum Shuttle VS-1.5 1 4 Stand Base A548-158 1 5 Tray Top A517-018 1 6 Self-Tapping Screw .5" A539-217 4 7 Rubber Foot A548-161 4 8 Plastic Insert A548-162 3 9 Self-Tapping Scres .75" A539-218 3

These cleaning and sanitizing instructions are only a guideline to be used for the cleaning and sanitizing of the VS-1.5S and VS-S with VS-1.5. In-house cleaning and sanitizing methods may be more effective. Grindmaster assumes no responsibility for the food born illness and/or sickness caused by using improper sanitizing methods.
For cleaning and sanitizing of the VS-1.5S and VS-S with VS-1.5 the three-sink method is recommended. The three- sink method consists of the sink full of hot soapy water using an approved detergent, a fresh water rinse, and an aqueous sanitizing solution using an approved iodine sanitizer with mixture between 12.5-25 PPM.
solution for cleaning. f) Reassemble unit. g) Fully fill unit with sanitizing solution for 5 minutes and drain through fully opened faucet. h) Wipe outside of the unit with a clean cloth moistened with sanitizing solution. i) Place unit on rack upside down to thoroughly air-dry.
top thoroughly. b) Wipe outside of the stand with a clean cloth moistened with sanitizing solution. c) Place parts on rack to thoroughly air-dry.
Remove and air dry.









Wiring Diagram - Precision Brew 430 Series 120/208 or 120/240V Models APB-430V2, APBVSA-430V2, and APBIC-430V2
:+7
%/.
9:505(/(07
%/.
%/. %/.
32:(5 0$67(5 237,21$/
7(50,1$/ %/2&.
:$50(5
:+7 6:,7&+
:$50(5/,*+7
:+7
32:(5 6833/
9:505(/(07
%/.
%/. %/.
6:,7&+ :$50(5
:$50(5/,*+7
:+7
:+7
:+7
%/.
6((:$50(5 &,5&8,7',$*
:+7
%/.
%/.
9$&
:+7
:+7
%5(:9$/9(/()7YDF
%5(:9$/9(5,*+7YDF
:$7(5
:$7(57$1.
/()76+877/(6:,7&+
5,*+76+877/(6:,7&+ 7+(50,6725 352%(
5,*+7%$6./2&.62/
/()7%$6./2&.62/
YGF

Wiring Diagram - Precision Brew 330 Series 120/208V, 120/240V Models APB-330V2, APBVSA-330V2, and APBIC-330V2
:+7
%/.
32:(5 0$67(5 237,21$/
7(50,1$/%/2&.
32:(5 6833/
7$1.+($7(5
%/.
6((:$50(5 &,5&8,7',$*
:+7
%51 :+7
9:505(/(07
%/.
%/. %/.
:$50(5
:$50(5/,*+7
6:,7&+
:+7
:+7
%/.
%/.
9$&
:+7
:+7
%<3$669$/9(YDF
%5(:9$/9(YDF
:$7(57$1.
:$7(5
6+877/(6:,7&+ 7+(50,6725 352%(
%$6./2&.62/
4/5#(0!$

230V, 208V, or 240V without Neutral
Models APB-430V2, APBVSA-430V2, APBIC-430V2, APB-430V2E230, APBVSA-430V2E230,
:+7
%/.
259:505(/(07
32:(5 0$67(5 237,21$/
%/.
%/. %/.
7(50,1$/%/2&.
:$50(5
6:,7&+
:$50(5/,*+7
:+7
:+7
32:(5 6833/
259:505(/(07
%/.
%/. %/.
6:,7&+ :$50(5
:$50(5/,*+7
:+7
:+7
%/.
6((:$50(5 &,5&8,7',$*
:+7
:+7
RU 75$16)250(5
%/.
%/.
&20 :+7
9$&
:+7
%5(:9$/9(/()7YDF
%5(:9$/9(5,*+7YDF
:$7(57$1.
:$7(5
/()76+877/(6:,7&+
5,*+76+877/(6:,7&+ 7+(50,6725 352%(
5,*+7%$6./2&.62/
/()7%$6./2&.62/
YGF

230V, 208V, or 240V without Neutral Models APB-330V2, APBVSA-330V2, APBIC-330V2, APB-330V2E230, APBVSA-330V2E230, APBIC-330V2E230
:+7
%/.
32:(5 0$67(5 237,21$/
7(50,1$/%/2&.
32:(5 6833/
7$1.+($7(5
%/.
6((:$50(5 &,5&8,7',$*
:+7
9 %51 :+7
259:505(/(07
:$50(5 %/.
%/. %/.
:$50(5/,*+7
:+7
6:,7&+
:+7
%/.
%/.
&20 :+7
9$&
:+7
%<3$669$/9(YDF
%5(:9$/9(YDF
:$7(57$1.
:$7(5
6+877/(6:,7&+ 7+(50,6725 352%(
%$6./2&.62/
4/5#(0!$



Refers to software version number.
Subject to change.


0511 Form # AM-346-02 Part # A090-842
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Overfilling water tank when power is Off | p.20 | ||
| Overfilling water tank only when power is On | p.20 | ||
| Tank does not refill | p.21 | ||
| Tank does not heat | p.22 | ||
| Brew volume too large or too small | p.24 | ||
| Brew volume erratic | p.25 | ||
| Brew volume erratic | p.25 | ||
| Brew cycle will not start | p.25 | ||
| Sprayhead will not stop dripping water | p.26 |