312786G EN Instructions-Parts Dump Valve and Third Purge Valve Kits For use with ProMix ® 2KS Elec tronic Proportioners. For professional use only. See page 2 for ki t part numbe rs and m aximum wo rking press ure. Important Safety Instructions Read all warnings and instructions in t his manual.
Kits 2 312786G Kits 15V821 Dump Valve Kit For wall m ount ProMi x 2KS Elec tronic Pr oportioner s 3000 psi (21 MPa , 210 bar) M aximum F luid Wo rking Pres sure 100 psi ( 0.7 MPa, 7 bar) Max imum Air W orking P ressure See pages 3 and 14 15V822 Robo Dump Valve Kit For robo mount Pr oMix 2KS E lectronic Pr oportioner s 300 psi ( 2.
Installa tion 312786G 3 Installa tion 15V821 Dump Valve Kit for Wall Panel NOTE: These ins tructions s how this kit being insta lled on the A s ide. It may a lso be in stalled on the B side . 1. Shut off th e fluid s upply to t he dose valv e (V) at t he front of th e wall pan el.
Inst allation 4 312786G F IG . 2: Solenoid Manifolds F IG . 3: 255765 Fluid Panel Control Board, De tail View of Solenoid Connections TI 13116 a Wall Panel 3rd F lus h Valve Dump Valv e A Dump Valve B.
Installa tion 312786G 5 15V354 Third Flush Valve Kit fo r Wall Panel 1. Shut o ff the air and fluid su pply to th e ProMix 2 KS. 2. Relieve pressure . See you r ProMix 2K S Opera tion Manual. 3. See F IG . 4. Remove the air flush v alve (AFV ) from the fluid mix mani fold (FM) an d set it asi de.
Inst allation 6 312786G 15V822 Dump Valve Kit fo r RoboMix NOTE: These ins tructions s how this kit being insta lled on the B s ide. It may a lso be in stalled on the A side . 1. See F IG . 7. Shut off the flui d supply to the dose valve ( V) in t he RoboMix .
Installa tion 312786G 7 15V202 Third Flush Valve Kit fo r RoboMix 1. Shut o ff the air and fluid su pply to th e ProMix 2 KS. 2. Relieve pressure . See you r ProMix 2K S Opera tion Manual. 3. See F IG . 8. Remove the plug (A) fr om the ai r flush valve (A FV).
Inst allation 8 312786G 15X247 Auto Dum p Valve Kit 1. Close the compo nent A and componen t B sh utoff valves on the flu id manifo ld. 2. Trigger the gun to relieve fluid pr essure downs tream of the flui d manifold.
Installa tion 312786G 9 F IG . 9: 15X 247 Kit Instal lation TI142 83b 1 2 3 6 7 8 TI1311 6a 5 9 4 T GFB1 GFB2 J8 (s ee F IG . 3 for det ails) Wall Panel.
Schema tic Diag rams 10 312786G Schemati c Diag rams System Pneumatic Schem atic 3/8 AIR FIL TER MANU AL DRAIN 5 MICRON W ALL MOUNT ONL Y FLUSH AIR T O FLUID INLET 1/4 TUBE TO MANIFOLD 1/4 TUBE 4-W A .
Schemati c Diagram s 312786G 11 Tubing Schem atic TI1386 2a TI13857 a TI13858 a A2 A4 A6 A8 A2 A4 A6 A8 B1 B3 B5 B7 B1 B3 B5 B7 13 13 DA DB DA DB TI13861a T I1386 0a TI13863a GFB1-C GFB2 -C GFB1 -S GF.
Schema tic Diag rams 12 312786G Table 1: Tubing Chart Color Description Starting Point Ending Point Tube OD in. (mm) Tube Ref. No. Green Dose A On A2 A2 5/32 (4 ) 336 Green Dose B On A4 A4 5/32 (4 ) 3.
Schemati c Diagram s 312786G 13 System Electrical Sc hematic Hazardous Area HAZARDOUS AREA +12VDC I/S COM SHIELD J10 1 2 3 1 2 3 4 5 6 J3 PWR (RED) COM (BLACK) SIG ( WHITE) SHIELD/GRN PWR (RED) COM (B.
Parts 14 312786G Parts 15V821 Dump Valve Kit for Wall Panel * Parts in cluded in 1 6A079 D ump Va lve Repla cement Kit (p urchase s eparatel y). † Orde r Kit 16A56 0 to replace a single s eat. The ki t includes a seat (11) and o-ri ngs (4 and 1 4). NOTE: The standa rd valve se at (11) is SST.
Parts 312786G 15 15V354 Third Flush Valve Kit fo r Wall Panel ‡ Parts include d in Valve Seat Kit 24A861 ( purchase separa tely) . Parts labeled n/a are no t available separat ely. 2‡ 4 8 1 3 5 ‡6 6 7 9 10 ‡11 TI1295 3a TI1265 2a 12 15 Ref. No.
Parts 16 312786G 15V822 Dump Valve Kit fo r RoboMix Parts labeled n/a are no t available separat ely. TI130 45a TI 12655 a Dump Valv e A Dump Valve B TI130 47a 4 11 9 1 10 2 3 6 5 8 Ref.
Parts 312786G 17 15V202 Third Flush Valve Kit fo r RoboMix Parts l abeled n/a are not a vailable s eparatel y. TI1265 5a TI 13047 a TI1304 6a 5 6 1 10 3 2 4 8 9 Ref.
Parts 18 312786G 15X247 Auto Dum p Valve Kit † Order Ki t 16A560 t o replac e a sing le seat. The kit include s a seat ( 6) and o -rings (3 a nd 7). NOTE: The st andard valve se at (6) is SST. To inst all a carbid e seat, order Kit 24U054. The kit includes a single carbid e seat and o-rings 3 and 7.
Notes 312786G 19 Notes.
All written and visual data contained in this document reflects the lat est product information available at the time of publica tion. Graco rese rves the right to make changes at any time without notice. 312786 Graco H eadquarte rs: Minnea polis International O ffices: Bel gium, Chin a, Japan, Korea GRACO INC.
An important point after buying a device Graco TI12954a (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Graco TI12954a yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Graco TI12954a - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Graco TI12954a you will learn all the available features of the product, as well as information on its operation. The information that you get Graco TI12954a will certainly help you make a decision on the purchase.
If you already are a holder of Graco TI12954a, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Graco TI12954a.
However, one of the most important roles played by the user manual is to help in solving problems with Graco TI12954a. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Graco TI12954a along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center