EN
Graco logo
Official user manual

Graco SDM5

44 pages·2.7 MB·Marine Instruments·PDF·ENDEFRITNLJA
Graco SDM5
Table of Contents 34 sections Models · SDM5 Manual Dispense Electronic Meters · SDM15 Manual Dispense Electronic Meters · SDP5 Preset Dispense Electronic Meters · … ShowHide
Page 1 of the Graco SDM5 user manual — NOTICE
Page 1 · click to enlarge
Page 1

INSTRUCTIONS SDM5 & SDM15 (Manual); SDP5 & SDP15 (Preset) Meters

EN

For metered dispense of oils and 50:50 antifreeze/water mix fluids. For professional use only.

Not approved for use in European explosive atmosphere locations.

Maximum Working Pressure: 1500 psi (10 MPa, 103 bar) Maximum Working Pressure (50:50 antifreeze/water mix): 900 psi (6.2 MPa, 62 bar) Maximum Flow Rate:14 gpm (53 lpm)

List of Models page 2

Graco SDM5 — List of Models page 2 diagram (page 1)
Fig. 1 · List of Models page 2

NOTICE

This dispense valve is designed to dispense petroleum-based lubricants and antifreeze only. Do not dispense windshield washer solvent with this dispense valve.

Preset Meter shown · ti11821

Page 2 of the Graco SDM5 user manual — Models
Page 2 · click to enlarge
Page 2

Models

SDM5 Manual Dispense Electronic Meters

Model NumberSwivelExtension DescriptionNozzleFluid Type 2553481/2” npt(f)Flexible ExtensionAutomatic, non-drip, quick closeOil 2553491/2” npt(f)Gear Lube ExtensionNon-drip, quick closeGear Lube 2553501/2” npt(f)Rigid ExtensionAutomatic, non-drip, quick closeOil 2558021/2” npt(f)Rigid ExtensionAutomatic, non-drip, quick closeAnti-freeze 2558031/2” npt(f)Flexible ExtensionAutomatic, non-drip, quick closeAnti-freeze 24H1081/2-14 BSPPFlexible ExtensionAutomatic, non-drip, quick closeOil 24H1101/2-14 BSPPGear Lube ExtensionNon-drip, quick closeGear Lube 24H1121/2-14 BSPPRigid ExtensionAutomatic, non-drip, quick closeOil 24H1301/2-14 BSPPRigid ExtensionAutomatic, non-drip, quick closeAnti-freeze 24H1321/2-14 BSPPFlexible ExtensionAutomatic, non-drip, quick closeAnti-freeze 24H1091/2-14 BSPTFlexible ExtensionAutomatic, non-drip, quick closeOil 24H1111/2-14 BSPTGear Lube ExtensionNon-drip, quick closeGear Lube 24H1131/2-14 BSPTRigid ExtensionAutomatic, non-drip, quick closeOil 24H1311/2-14 BSPTRigid ExtensionAutomatic, non-drip, quick closeAnti-freeze 24H1331/2-14 BSPTFlexible ExtensionAutomatic, non-drip, quick closeAnti-freeze

Models

Page 3 of the Graco SDM5 user manual — SDM15 Manual Dispense Electronic Meters
Page 3 · click to enlarge
Page 3

SDM15 Manual Dispense Electronic Meters

Model NumberSwivelExtension DescriptionNozzleFluid Type 2558003/4” npt(f)Rigid ExtensionNon-drip, quick closeOil or Antifreeze 2558013/4” npt(f)Flexible ExtensionNon-drip, quick closeOil or Antifreeze 2568361/2” npt(f)Rigid ExtensionNon-drip, quick closeOil or Antifreeze 2568371/2 npt(f)Flexible ExtensionNon-drip, quick closeOil or Antifreeze 24H1263/4-14 BSPPRigid ExtensionNon-drip, quick closeOil or Antifreeze 24H1283/4-14 BSPPFlexible ExtensionNon-drip, quick closeOil or Antifreeze 24H1501/2-14 BSPPRigid ExtensionNon-drip, quick closeOil or Antifreeze 24H1521/2-14 BSPPFlexible ExtensionNon-drip, quick closeOil or Antifreeze 24H1273/4-14 BSPTRigid ExtensionNon-drip, quick closeOil or Antifreeze 24H1293/4-14 BSPTFlexible ExtensionNon-drip, quick closeOil or Antifreeze 24H1511/2-14 BSPTRigid ExtensionNon-drip, quick closeOil or Antifreeze 24H1531/2-14 BSPTFlexible ExtensionNon-drip, quick closeOil or Antifreeze

Models

Page 4 of the Graco SDM5 user manual — SDP5 Preset Dispense Electronic Meters
Page 4 · click to enlarge
Page 4

SDP5 Preset Dispense Electronic Meters

Model NumberSwivelExtension DescriptionNozzleFluid Type 2552001/2” npt(f)Rigid ExtensionAutomatic, non-drip, quick closeOil 2553511/2” npt(f)Flexible ExtensionAutomatic, Non-drip, quick closeOil 2553521/2” npt(f)Gear Lube ExtensionNon-drip, quick closeGear Lube 2553551/2” npt(f)Rigid ExtensionAutomatic, non-drip, quick closeAnti-freeze 2553561/2” npt(f)Flexible ExtensionAutomatic, non-drip, quick closeAnti-freeze 24H1061/2” BSPPRigid ExtensionAutomatic, non-drip, quick closeOil 24H1141/2” BSPPFlexible ExtensionAutomatic, Non-drip, quick closeOil 24H1161/2” BSPPGear Lube ExtensionNon-drip, quick closeGear Lube 24H1221/2” BSPPRigid ExtensionAutomatic, non-drip, quick closeAnti-freeze 24H1241/2” BSPPFlexible ExtensionAutomatic, non-drip, quick closeAnti-freeze 24H1071/2” BSPTRigid ExtensionAutomatic, non-drip, quick closeOil 24H1151/2” BSPTFlexible ExtensionAutomatic, Non-drip, quick closeOil 24H1171/2” BSPTGear Lube ExtensionNon-drip, quick closeGear Lube 24H1231/2” BSPTRigid ExtensionAutomatic, non-drip, quick closeAnti-freeze 24H1251/2” BSPTFlexible ExtensionAutomatic, non-drip, quick closeAnti-freeze

Models

Page 5 of the Graco SDM5 user manual — SDP15 Preset Dispense Electronic Meters
Page 5 · click to enlarge
Page 5

SDP15 Preset Dispense Electronic Meters

Model NumberSwivelExtension DescriptionNozzleFluid Type 2553533/4” npt(f)Rigid ExtensionNon-drip, quick closeOil or Antifreeze 2553543/4” npt(f)Flexible ExtensionNon-drip, quick closeOil or Antifreeze 2568381/2” npt(f)Rigid ExtensionNon-drip, quick closeOil or Antifreeze 2568391/2” npt(f)Flexible ExtensionNon-drip, quick closeOil or Antifreeze 24H1183/4-14 BSPPRigid ExtensionNon-drip, quick closeOil or Antifreeze 24H1203/4-14 BSPPFlexible ExtensionNon-drip, quick closeOil or Antifreeze 24H1541/2-14 BSPPRigid ExtensionNon-drip, quick closeOil or Antifreeze 24H1561/2-14 BSPPFlexible ExtensionNon-drip, quick closeOil or Antifreeze 24H1193/4-14 BSPTRigid ExtensionNon-drip, quick closeOil or Antifreeze 24H1213/4-14 BSPTFlexible ExtensionNon-drip, quick closeOil or Antifreeze 24H1551/2-14 BSPTRigid ExtensionNon-drip, quick closeOil or Antifreeze 24H1571/2-14 BSPTFlexible ExtensionNon-drip, quick closeOil or Antifreeze

Models

Page 6 of the Graco SDM5 user manual — Warnings
Page 6 · click to enlarge
Page 6

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING SKIN INJECTION HAZARD High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point dispense valve at anyone or at any part of the body. • Do not put your hand over the end of the dispense nozzle. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. BATTERY SAFETY The battery may leak, explode, cause burns, or cause an explosion if mishandled: • You must use the battery type specified for use with the equipment. • Sparking can occur when changing batteries. Only replace the battery in a non-hazardous location, away from flammable fluids or fumes. • Handle and dispose of battery properly - do not short circuit, charge, force over discharge, disassemble, crush, penetrate, incinerate, or heat the battery to a temperature exceeding 185° F (85° C).
Page 7 of the Graco SDM5 user manual — Warnings
Page 7 · click to enlarge
Page 7
WARNING FIRE AND EXPLOSION HAZARD When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources, such as cigarettes and portable electric lamps. • Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline. • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present. • Ground all equipment in the work area. • Use only grounded hoses. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. PERSONAL PROTECTIVE EQUIPMENT Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not limited to: • Protective eyewear, and hearing protection. • Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer. CALIFORNIA PROPOSITION 65 This product contains a chemical known to the State of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling.
Page 8 of the Graco SDM5 user manual — A
Page 8 · click to enlarge
Page 8

Installation

Typical Installations (F IG . 1)

Mounting Bracket (F IG . 2)

The typical installation shown in FIG. 1 is only a guide. It is not a complete system design. Contact your Graco distributor for assistance in designing a system to suit your needs.

Mounting Bracket Kit 249440 is available for resting the dispense valve on a console.

Graco SDM5 — Typical Installations (F IG . 1) diagram (page 8)
Fig. 2 · Typical Installations (F IG . 1)

NOTICE

The dispense valve is not designed for in-line installation. Do not install with a shutoff valve on the outlet side of the meter. Such installation could result in damage to the meter housing cover.

Graco SDM5 — NOTICE diagram (page 8)
Fig. 3

B

D

E

Drum Mount Bracket (F IG . 3)

Mounting Bracket 15B750 is available for resting the dispense valve on a drum.

Graco SDM5 — B diagram (page 8)
Fig. 4

A

ITEMDESCRIPTION AElectronic metered dispense valve BFluid shut-off valve CHose DHose reel fluid inlet hose EHose reel A Thermal Relief Kit (not shown) is required. The kit required will vary by pump selected. See Parts, page 42 for a list of available kits.

Installation · ti11822 · ti11823

Page 9 of the Graco SDM5 user manual — Installation Procedure
Page 9 · click to enlarge
Page 9

Pressure Relief Procedure

Air compressor: Follow manufacturer’s recommendations.

Fluid supply container: Follow local code.

To maintain grounding continuity when flushing or relieving pressure: hold a metal part of the dispense valve firmly to the side of a grounded metal pail, then trigger the valve.

This equipment will stay pressurized until the pressure has been manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the dispense valve or splashing fluid, follow this Pressure Relief Procedure when ever you:

Pre-Installation Procedure

  • Are instructed to relieve pressure.
  • Check, clean or service any system equipment.
  • Install or clean fluid nozzles or filter.
1. Turn off power supply to the pump or close upstream ball valve.
1. Relieve pressure , page 9.
2. Trigger the dispense valve into a waste container to relieve pressure.
2. Close the shut-off valve (B, F IG . 1).
3. Ground the hose and reel or console, page 9. Leave at least two threads bare when using PTFE tape. The bare threads ensure a ground is maintained.
3. Open any bleed-type master air valves and fluid drain valves in the system.
4. Leave the drain valve open until you are ready to pressurize the system.

Installation Procedure

NOTICE

Grounding

  • If this is a new installation or if the fluid lines are contaminated, flush the lines before you install the metered valve. Contaminated lines could cause the valve to leak.
  • Never dispense compressed air with meter. Doing so will damage meter.

FIRE HAZARD: Conductive metal surfaces on the meter must not make contact with any positively charged metal surface, including (but not limited to), the starter solenoid terminal, alternator terminal or battery terminal. Such contact could cause electrical arcing and a fire.

If this is an existing installation, go to Installing Meter section, page 10. The following procedure, Steps 1-5 are the Flushing Procedure.

The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit.

1. Close the fluid shut-off valve (B, F IG . 1, page 8) at each dispense position.
  • 2. Make sure:
  • main fluid outlet valve at the pump is closed,
  • air pressure to the pump motor is adjusted, and
  • air valve is open.

Pump: Follow manufacturer’s recommendations.

Air and fluid hoses: Only use electrically conductive hoses. Check electrical resistance of hoses. If total resistance to ground exceeds 29 megohms, replace hose immediately.

Installation · Flushing

Page 10 of the Graco SDM5 user manual — Installing Meter (F IG . 4
Page 10 · click to enlarge
Page 10

Installing Tube Extension (F IG . 5)

3. Slowly open the main fluid valve. a. Place the hose end (with no dispense valve connected) into a container for waste oil. b. Secure the hose in the container so it will not come out during flushing. c. If you have multiple dispense positions, first flush the dispense position farthest from the pump and work your way toward the pump.
Graco SDM5 — Installing Tube Extension (F IG . 5) diagram (page 10)
Fig. 5 · Installing Tube Extension (F IG . 5)
4. Slowly open the shut-off valve (B) at the dispense position. Flush out a sufficient amount of oil to ensure that the entire system is clean; then close the valve.
5. Repeat Step 4 at all other positions.

Installing Meter (F IG . 4

NOTICE

Do not use PTFE tape or thread sealant on threads of extension tube (20). This could cause the fitting to leak.

1. a. Loosen nut (a) until it is completely off tube threads. b. Thread extension (20) into housing (b) until it bottoms out. c. Align extension (20) with meter housing and handle (c). d. Firmly tighten nut (a).
1. Relieve pressure, page 9.
Graco SDM5 — Installing Meter (F IG . 4 diagram (page 10)
Fig. 6 · Installing Meter (F IG . 4
2. Slide the swivel boot (32) back, over the hose, small end first, to access the swivel fitting (a).
3. Apply thread sealant to the male threads of the hose fitting. Thread the hose fitting into the meter swivel (31). Use two wrenches to tighten securely (F IG . 4).

Make sure you let the sealant cure to the manufac- turer’s recommendations before circulating fluid through the system.

Show 5 more labels / short text on this page
Installation · b · a · ) · 32 a
Page 11 of the Graco SDM5 user manual — NOTICE
Page 11 · click to enlarge
Page 11

Installing Nozzle (F IG . 6)

Graco SDM5 — Installing Nozzle (F IG . 6) diagram (page 11)
Fig. 7 · Installing Nozzle (F IG . 6)
1. a. Thread new nozzle (33) onto extension (20). b. With an open-end adjustable wrench on flats of nozzle bushing, tighten firmly.
  • Only tighten nozzle with wrench on flats of the nozzle bushing.
  • Do not disassemble the bushing from nozzle. Disassembly will affect performance of the nozzle.
2. Open automatic twist lock nozzle and all fluid shut-off valves. Start pump to pressurize system. See Operation Screens, Dispensing in either the Manual or Preset Mode instructions beginning on page 21 for complete meter operation information.
3. To ensure dispensing accuracy, purge all air from the fluid lines and dispense valve before you use it.
4. Set the system flow to the desired flow rate.

NOTICE

Do not trigger meter when nozzle is closed. Fluid will build up behind the nozzle, leak from the nozzle, and unexpectedly be expelled when the nozzle is opened. If you do accidentally trigger the meter with the nozzle closed, point the nozzle into a waste bucket and open the nozzle to relieve pressure and expel the built up fluid.

Installation

Page 12 of the Graco SDM5 user manual — 5-Way Menu Navigation Button (F IG . 7)
Page 12 · click to enlarge
Page 12

Meter Overview

Navigation and Modes

Meter Display

Adjusting Screen Contrast using ARROWS

Graco SDM5 — Meter Display diagram (page 12)
Fig. 8 · Meter Display

On the Setup Home Screen (page 13), use the LEFT and RIGHT ARROWS to adjust the screen contrast.

  • Darken the Screen: Press the RIGHT ARROW multiple times.
  • Brighten the Screen: Press the LEFT ARROW multiple times.
  • Asleep: Battery-saving mode. The display goes blank after 2 minutes of inactivity during normal operation. Unit continues to keep track of amount dispensed while the display is asleep.
  • Awake : Display comes awake from sleep mode when you press any ARROW or the ENTER button or when you squeeze the trigger to dispense fluid.

Locking and Unlocking Trigger

The Preset Meters only, include a locking trigger feature that allows the user to lock the trigger in the dispense position as shown in FIG. 8. To release the lock, firmly squeeze the trigger to the handle.

ti11824 5-Way Menu Navigation Button

Preset Meters Only FIG. 7

5-Way Menu Navigation Button (F IG . 7)

Graco SDM5 — 5-Way Menu Navigation Button (F IG . 7) diagram (page 12)
Fig. 9 · 5-Way Menu Navigation Button (F IG . 7)
  • Includes 4 direction ARROWS (UP, DOWN, LEFT, RIGHT) and a center, ENTER button.
  • Pressing the direction ARROWS allows user to easily scroll through menus. To select/store your selection, you must press the center, ENTER button.
  • Pressing and holding a direction ARROW down allows user to scroll through menus quickly.
Graco SDM5 — 5-Way Menu Navigation Button (F IG . 7) diagram (page 12)
Fig. 10 · 5-Way Menu Navigation Button (F IG . 7)
Show 4 more labels / short text on this page
Meter Overview · Asleep/Awake Mode · Unlocked · Locked
Page 13 of the Graco SDM5 user manual — MOBIL1 5W-20
Page 13 · click to enlarge
Page 13

Setup Mode Screens

If you are in Operation Mode you must be on the Home Screen shown in FIG. 10, to access the Setup Mode Screens. (A complete description of the Home Screen is provided on page 20).

To display the Home Screen:

1. Wake up the meter by pressing any button on the key pad.
2. When an operation mode screen displays (such as the one shown in F IG . 9):

MOBIL1 5W-20

a. Use the RIGHT ARROW to move the curser over the House icon (a).

10.56 QTS

b. Press center, ENTER button to display the Home Screen (FIG. 10).

Manual Meters Preset Meters

MOBIL1 5W-20

MOBIL1 5W-20

MANUAL PRESET TOTALS

MANUAL TOTALS

Setup Mode Screens · a · ti12184a ti12175a

Page 14 of the Graco SDM5 user manual — A
Page 14 · click to enlarge
Page 14

Main Setup Screen (F IG . 12)

Displaying Setup Screen from an Operation Mode Screen

The Main Setup Screen is the first screen displayed when you enter the Setup Mode. This screen displays a list of the available Setup Screens and also includes a link back to the Home Screen.

Graco SDM5 — Displaying Setup Screen from an Operation Mode Screen diagram (page 14)
Fig. 11 · Displaying Setup Screen from an Operation Mode Scree…

Manual Meters Screens:

  • UNITS/LIMIT
  • CALIBRATE
  • BANNER
  • LANGUAGE
  • HOME

Preset Meters include all the Manual Meter’s Setup Screens and also a PRESET screen.

1. Hold down the RIGHT ARROW (a) only, for a few seconds (F IG . 11).
  • UNITS/LIMIT
  • CALIBRATE
  • PRESET
  • BANNER
  • LANGUAGE
  • HOME
2. Then at the same time, also press the center, ENTER button (b) (F IG . 11). Hold both buttons down until the Main Setup Screen shown in F IG . 12 displays.

Manual Meters Preset Meters

A

A

UNITS/LIMIT

UNITS/LIMIT

CALIBRATE BANNER

CALIBRATE

B

B

PRESET BANNER

LANGUAGE HOME

LANGUAGE HOME 1.23.45

1.23.45

Main Screen Features (FIG. 12)

B. Setup Screens: Screens available to user.

A. Screen Identifier Icon: Wrench icon displays in the upper right corner when user is on the Main Screen of the Setup screens.

1. Use UP or DOWN ARROWS to select a screen from the list.
2. Press center, ENTER button to confirm selection. Selected screen displays.
1. Software Version Number: Reference number. You may be asked to provide this number when contacting Graco for technical support.
Show 4 more labels / short text on this page
Setup Mode Screens · All Meters · (a) (b) · ti12177a ti12186a
Page 15 of the Graco SDM5 user manual — UNITS = QTS C
Page 15 · click to enlarge
Page 15

Units/Limit Screen (F IG . 13)

Sets the units of measurement to pints, quarts, liters, or gallons.

Preset Meters Manual Meters

UNITS = QTS C

UNITS = QTS

G

MANUAL LIMIT = 5.0

QTS

D E

E F

QTS

5.0 D

Units/Limit Screen Features (FIG. 13)

All meters include C - E

Preset meters also include F - G

C. Units Mode: Displays measurement unit that was selected using the Set Measurement Units button (E).

F. Set Manual Dispense Limit field: Sets maximum quantity of fluid that can be dispensed in Manual Mode.

To change/set the Manual Dispense Limit:

D. Wrench Icon: Returns user to Main Setup Screen.

1. Use RIGHT ARROW to move curser to Manual Dispense Limit field (F).

E. Set Measurement Units button/field: Sets unit of measurement as pint, quart, gallon or liter.

2. Use UP or DOWN ARROWS to increase and decrease displayed amount.

To change/set the Unit of Measurement:

3. When amount you want to use is shown in field, press center, ENTER button to confirm amount. Confirmed amount displays on screen (G).
1. Use LEFT or RIGHT ARROW to move curser to the Set Measurement field (E).
2. Use UP or DOWN ARROWS to display measurement unit choices: PTS, QTS, L, GAL.
4. When you have finished making changes, use the RIGHT ARROW button to move curser over Wrench icon.
3. Press center, ENTER button to confirm selection. Selected measurement unit is displayed on screen (C).
5. Press center, ENTER button to return to Main Setup Screen.
4. When you are finished making changes, use the RIGHT ARROW to move curser over Wrench icon.

G. Manual Limit Confirmation: Displays maximum quantity of fluid that can be manually dispensed at one time. Amount is assigned on the task bar Set Manual Dispense Limit field (F). Preset dispense amounts are not affected by the manual dispense limit you set.

5. Press center, ENTER button to return to Main Setup Screen.

Setup Mode Screens · For All Meters

Page 16 of the Graco SDM5 user manual — J
Page 16 · click to enlarge
Page 16

Calibrate Screen (F IG . 14)

All meters include D - M

D. Wrench Icon: Returns user to Main Screen.

Recalibrates the meter for different fluids.

J. Calibration Factor: Displays amount operator dispensed during meter calibration.

Table 1. Calibration Factors

K. Preset Calibration Factor: Preset calibration amount displays.

Oil (10W - 30) 173 183

Gear Lube 173 183

Adjusting the Preset Calibration Factor:

1. Use your LEFT or RIGHT ARROW to move the curser to the Calibration Factor Field (K) .
2. Use the UP or DOWN ARROW to manually adjust the Preset Calibration Factor up or down (this can only be done on Calibrate Screen 1 (F IG . 14).
  • Calibration factors at 70°F (21°C) at 2.0 gpm (7.6 lpm).
  • Calibration number may vary slightly due to temperature or flow rate.
3. Press center, ENTER button to confirm new setting. New setting displays in Calibration Factor field (J).
Graco SDM5 — Calibrate Screen (F IG . 14) diagram (page 16)
Fig. 12 · Calibrate Screen (F IG . 14)

L. Start/End button: Clicked at the start and completion of calibration. See Recalibrating the Meter (page 17).

M. Dispense: Only appears on Screen 2 (FIG. 14). Displays amount operator dispensed during calibration test.

J

D

K

M

Show 10 more labels / short text on this page
Setup Mode Screens · For All Meters · Calibration Number · Fluids · Quarts Liters · Automatic Transmission Fluid · 167 176 · Antifreeze 159 168 · Calibrate Screen 1 · Calibrate Screen 2
Page 17 of the Graco SDM5 user manual — OR
Page 17 · click to enlarge
Page 17

Recalibrating the Meter (FIG. 14)

3. Dispense exactly 1 quart (or 1 liter) of fluid into a calibrated 1 quart (or 1 liter) container.

The meter is shipped from the factory with the default calibration factor for 10W30 motor oil - at 70°F (21°C). This calibration factor is sufficiently accurate for most oils. If other fluids are used or if greater accuracy is required, the meter can be recalibrated by performing one of the following recalibration methods.

The Calibration Factor will appear on the screen in the Calibration Factor field (J).

4. Use the LEFT or RIGHT ARROWS to select END (L) on Calibrate Screen 2.
1. Choosing a Calibration Factor From the Calibration Table 1
5. Press the center, ENTER button to confirm selection. Calibrate Screen 1 will appear.
6. When you have finished making changes, use the RIGHT ARROW button to move curser over Wrench icon.

Calibration factors provided in Table 1 (page 16), are only approximate, but sufficient for most appi- cations. For the most accuracy, use method 2, Manual Calibration Procedure.

7. Press center, ENTER button, to return to Main Setup Screen.
1. Use LEFT or RIGHT ARROW to move the curser to the Calibration Factor Field (K) .

To attain the most accurate calibration:

2. Use the UP or DOWN ARROWS to manually adjust the Preset Calibration Factor up or down until the number displayed matches the calibration factor you have chosen from Table 1.
  • Use the manual calibration procedure (Method 2).
  • Use a certified, graduated cylinder; either 1-Quart or 1-Liter volume in the system of Units to be used (either English or SI) for real-time dispenses.
3. Press center, ENTER button to confirm new setting. New setting displays in Calibration Factor field (J).
  • Calibrate using the exact fluid to be dispensed, at the temperature expected during dispense.
4. Use the RIGHT ARROW button to move curser over Wrench icon.
  • After calibration check your results by measuring a dispense.
5. Press center, ENTER button, to return to Main Setup Screen.
  • Be sure to remove all fluid from graduated cylinder between calibration attempts.

OR

  • Be sure meter is set to proper system of units for container you are using.
2. Manual Calibration Procedure

Once the meter has been calibrated, the unit of measure can be changed to any other unit, without the need for recalibration.

See FIG. 14, page 16 for the Calibrate Screens 1 and 2 referenced in the following instructions.

  • When an English unit (gallon, quarts, pints) is set as the measurement unit on the Units/Limit Screen, page 15, use a one quart graduated cylinder to calibrate the meter.
  • When a System International Unit (SI) (Liter) is set as the measurement unit on the Units/Limit Screen, use a one Liter graduated cylinder to calibrate the meter.
1. Use the LEFT or RIGHT ARROWS to select START (L) on Calibrate Screen 1.
2. Press the center, ENTER button to confirm selection. Calibrate Screen 2 will appear.

Setup Mode Screens

Page 18 of the Graco SDM5 user manual — D
Page 18 · click to enlarge
Page 18

Preset Screen (F IG . 15)

For Preset Meters Only

To set Preset amounts (FIG. 15):

Sets the default preset amounts. Typically, you would enter amounts you most frequently dispense.

1. Use the LEFT or RIGHT ARROWS to select one of the three amount fields (Q).
2. Use the UP or DOWN ARROWS to increase or decrease the number appearing in the field until the desired amount displays.

PRESET

Pressing and holding the ARROW button down, increases the scrolling speed.

4.0 6.0 10 1 2 3

3. Press center, ENTER button to confirm amount.

Q P

QTS

The amounts displayed do not automatically recal- culate quantities when changing between measure- ment units. For example, if you change from quarts to liters you must manually change the preset amounts.

D

4. When you have finished making changes, use the LEFT OR RIGHT ARROW button to move curser over Wrench icon.

Preset Meters include D, P and Q

D. Wrench Icon: Returns user to Main Screen.

P. Measurement Unit: Set on Units/Limit Screen, page 15.

5. Press center, ENTER button, to return to Main Setup Screen.

Q. Set Preset Amounts: Sets dispensing options for the Preset Dispense mode.

Sets up to 3, default preset quantities. The amounts can be listed in any order and do not have to be in a numeric order.

Setup Mode Screens

Page 19 of the Graco SDM5 user manual — LANGUAGE =
Page 19 · click to enlarge
Page 19

Banner Screen (F IG . 16)

Language Screen (F IG . 17)

Creates the information banner displayed across top of the Home, Manual and Preset Screens.

Sets language preference for text displayed on meter. Choices include English and Spanish.

LANGUAGE =

M O B I L 1 5 W

ENGLISH

S

D

T

D

ENGLISH

Language Screen Features D, S, and T

Banner Screen Features D and R

D. Wrench Icon: Returns user to Main Screen.

D. Wrench Icon: Returns user to Main Screen.

S. Language field: Identifies selected language.

R. Banner field: Information line. Provides space for up to 11 numeric and alpha characters and/or spaces.

T. Language field/button: When curser is over this button, each time UP or DOWN arrow is pressed, the name of the Language displayed on the button changes.

Using the DOWN ARROW button when a field is blank will also provide the following characters for selection: (period) “ . “; (forward slash) “ / “; or (dash) “ - ”.

To select your language:

To create a banner:

1. Use the LEFT or RIGHT ARROW to move the curser to the Language field/button (T).
1. Use the UP or DOWN ARROWS to scroll through numerals, then alpha characters and then blank/spaces.
2. Use UP or DOWN ARROWS to view language choices.
2. Press center, ENTER button to select characters. When character is selected, curser automatically moves to the next character field.
3. When the name of your language is displayed on the field/button (T), press the center ENTER button to confirm selection.

Use the RIGHT ARROW button to skip fields or if you do not need to use all 11 spaces, to return curser to the Wrench icon. After 11th character has been confirmed, curser automatically moves to Wrench icon (D).

The selected language is then displayed on screen in Language field (S).

After you press the center, ENTER button, the name on the field/button will also change from “SPANISH” to “EPANOL” and will appear this way on both the Lan- guage button (T) and in the Language field (S) on the screen.

3. Use the center, ENTER button, to return to the Main Setup Screen.
4. When you have finished making changes, use the LEFT OR RIGHT ARROW button to move curser over Wrench icon.
5. Press center, ENTER button, to return to Main Setup Screen.

Setup Mode Screens · For All Meters · For All Meters

Page 20 of the Graco SDM5 user manual — Home Screen (F IG . 18)
Page 20 · click to enlarge
Page 20

Dispensing Fluid and Operation Mode Screens

Dispensing Fluid and Operation Mode Screens

Graco SDM5 — Dispensing Fluid and Operation Mode Screens diagram (page 20)
Fig. 13 · Dispensing Fluid and Operation Mode Screens

FIRE HAZARD: Conductive metal surfaces on the meter must not make contact with any positively charged metal surface, including (but not limited to), the starter solenoid terminal, alternator terminal or battery terminal. Such contact could cause electrical arcing and a fire.

If you are in the Setup Mode, to display the Operation Mode Screens use the UP or DOWN ARROW button to select HOME from the list. Press the Center ENTER button to display the Operation Mode Home Screen shown in FIG. 18. A complete description of the Setup Mode Screens begins on page 13.

Home Screen (F IG . 18)

Preset Meters Manual Meters

Graco SDM5 — Home Screen (F IG . 18) diagram (page 20)
Fig. 14 · Home Screen (F IG . 18)
Graco SDM5 — Home Screen (F IG . 18) diagram (page 20)
Fig. 15 · Home Screen (F IG . 18)

All Meters include Include A - D

A. Screen Identifier Icon: House displays when user is on the Home Screen.

1. Use UP or DOWN ARROWS to scroll through options.
B. Operation ScreensList/menu of screen choices available to user. Operation Screen choices include:
2. Press center, ENTER button to confirm selection and display the screen.

C. Battery Indicator: Appears only on Home Screen. Shows current battery charge strength. Appears and flashes on all screens when battery’s charge is low.

  • MANUAL
  • TOTALS

D. Information Banner: Configurable information banner. Data is input on Setup Mode Banner Screen, page 19.

  • MANUAL
  • PRESET
  • TOTALS
Show 4 more labels / short text on this page
All Meters · ti12175a ti12184a · Manual Meters · Preset Meters
Page 21 of the Graco SDM5 user manual — G
Page 21 · click to enlarge
Page 21

Dispensing Fluid and Operation Mode Screens

Manual Dispense (F IG . 19)

To dispense in Manual Mode:

If display was asleep, press any button to wake it up.

D

MOBIL1 5W-20

MOBIL1 5W-20

10.56 QTS E

H

MANUAL PRESET TOTALS

F G

See FIG. 19 for terms D - H

D. Information Banner: Configurable information banner. Data is input on Setup Mode Banner Screen, page 19.

1. From HOME screen, use the UP or DOWN ARROWS to select MANUAL (F IG . 20).
2. Press center, ENTER button to confirm selection.The Manual Dispense screen (F IG . 21) appears.

E. Unit of Measurement: Identifies unit of measurement, pint, quart, gallon or liter. Measurement Unit is set on Setup Mode Units/Limits Screen, page 15.

MOBIL1 5W-20

F. Home Icon: Returns user to Home Screen.

G. Reset: Resets counter (H) to zero.

10.56 QTS

H

H. Counter: Before dispense has begun, display reads 0.00. As fluid is dispensed, counts up from zero.

To reset counter to zero after a dispense:

G

1. Use the LEFT or RIGHT ARROW button to move curser to RESET (G).
2. Press center ENTER button. The displayed amount in field H returns to zero.
3. Squeeze trigger to dispense fluid. If using a Preset meter, trigger may be locked during the dispense.

Fluid flows. The amount displayed counts up from zero or from the previously dispensed amount (FIG. 21) and displays in field H.

4. Release, or for Preset meters only, unlock trigger when you have dispensed the desired amount of fluid.

Fluid flow stops. Amount dispensed displays in field H.

5. Use LEFT or RIGHT ARROW to move curser to RESET button (G). Press center ENTER button to reset the displayed amount in field H to zero.

All Meters · Preset shown

Page 22 of the Graco SDM5 user manual — G
Page 22 · click to enlarge
Page 22

Dispensing Fluid and Operation Mode Screens

Preset Dispense (F IG . 22)

L. Preset Quantities: Use the UP or DOWN ARROW to select field L on the task bar.

a. Use the UP or DOWN ARROWS to scroll through the 3 available Preset Quantities (L). Each time you press the UP or DOWN ARROWS, one of the 3 preset amounts dis- plays on the task bar in field L.

D

MOBIL1 5W-20

b. When the Preset Quantity you want to dispense is shown in field L, press the center, ENTER button to select it.

2.50 QTS

H

E

J

XXXXXXXXXXXXXXXX

If a suitable preset quantity is not available, select an amount that is closest to the amount you want to dispense. Amounts can be modified following the procedure described on page 23.

G

F

See FIG. 22 for terms D - L

D. Information Banner: Configurable information banner. Data is input in Setup Mode, Banner Screen, page 19.

E. Unit of Measurement: Identifies unit of measurement, pint, quart, gallon or liter. Unit is selected in Setup Mode, Units/Limit Screen, page 15.

F. Home Icon: Returns user to Home Screen.

G. Reset: Resets counter (H) to zero.

H. Counter: Before dispense has begun, display reads 0.00. As fluid is dispensed, counts up from zero. At the same time the Progression Bar (J) displays a real-time, visual representation of the progress made toward completing the dispense.

J. Progression Bar: Displays a real-time, visual representation of the progress made toward completing the dispense. Runs in conjunction with Counter (H).

For example, in FIG. 22, a partial dispense of 2.5 quarts of the total Preset Dispense of 5.0 quarts is shown. The Progression Bar shows that approximately half the dispense is complete.

Preset Meters Only · L ti122410a

Page 23 of the Graco SDM5 user manual — MOBIL1 5W-20
Page 23 · click to enlarge
Page 23

Dispensing Fluid and Operation Mode Screens

To modify the amount selected:

a. Use the UP or DOWN ARROW to scroll up or down to increase or decrease the amount shown in field L. Each time you press the UP or DOWN ARROW the amount will increase or decrease in increments of 0.1 units.

To speed up the scrolling progression, press and hold the UP or DOWN ARROW.

b. IMPORTANT!!! When the new dispense amount is shown in field L, the number flashes, indicating a change has been made that requires confirmation.

To confirm new amount you MUST PRESS the center, ENTER button on the key pad within 15 seconds. If you begin a dispense without confirming the new amount, the Preset Amount will return to the previous confirmed amount shown in field L.

For example, in FIG. 23 (below) the original, confirmed Preset Dispense amount (A) was 4.0 qts. The amount was increased to 8.0 quarts and because it has not been confirmed, is flashing on the screen (B). After the user confirmed this change by pressing the center ENTER button on the key pad, the new dispense amount no longer flashes and is now set to dispense 8.0 quarts (C).

MOBIL1 5W-20

2.50 QTS

XXXXXXXXXXXXXXXX

A

B

8.0 8.0

To permanently modify the default Preset Quantities, see To set Preset amounts: on page 18.

Page 24 of the Graco SDM5 user manual — H
Page 24 · click to enlarge
Page 24

Dispensing Fluid and Operation Mode Screens

To dispense in Preset Mode:

3. Squeeze trigger to begin dispensing fluid. The trigger may be locked during the dispense.

If the display was asleep, press any button to wake up the display.

Fluid flows. The amount displayed counts up from zero or from the previously dispensed amount (FIG. 25) and displays in field H. A visual representation of the dispense progression also appears on the progression bar (J).

MOBIL1 5W-20

When the preset amount has been dispensed, fluid flow stops automatically. The total dispensed amount appears in field H.

MANUAL PRESET TOTALS

If you want to stop fluid flow before the preset amount is dispensed, release or unlock trigger. To continue dispensing fluid, squeeze and/or lock trigger again. Dispensed amount shown in field H and on progression bar (J) continues to count up toward preset amount.

1. From HOME screen, use the UP or DOWN ARROWS to select PRESET (F IG . 24).

If you want to continue dispensing fluid after preset amount has been dispensed, squeeze trigger. The meter continues dispensing fluid in Manual Mode until you release trigger.

2. Press center, ENTER button to confirm selection.The Preset Dispense screen (F IG . 25) appears.
4. Use LEFT or RIGHT ARROW to move curser to RESET button (G).

MOBIL1 5W-20

5. Press center ENTER button to reset the displayed amount in field H to zero and clear the progression bar (J).

2.50 QTS

H

J

XXXXXXXXXXXXXXXX

G

Page 25 of the Graco SDM5 user manual — M
Page 25 · click to enlarge
Page 25

Dispensing Fluid and Operation Mode Screens

Totals Screen (F IG . 26)

To display Totals Screen:

If the display was asleep, press any button to wake up the display.

M

MOBIL1 5W-20

QTS

N

GAL

MANUAL PRESET TOTALS

F G

See FIG. 26 for terms F, G, M - P

1. From HOME screen, use the UP or DOWN ARROWS to select TOTALS (F IG . 27).

F. Home Icon: Returns user to Home Screen.

G. Reset: Resets counter (M) to zero.

2. Press center, ENTER button to confirm selection.The Totals screen (F IG . 26) appears.

M. Resettable Total: Shows cumulative amount that has been dispensed in all modes. Can be reset to zero at any time with Reset button (G).

3. To reset Resettable Total field (M) to zero, use LEFT or RIGHT ARROW to move curser over RESET button (G).
N. TotalShows cumulative amount that has been
4. Press center ENTER button to reset the displayed amount in field M to zero.

dispensed in all modes for the life of the unit. Cannot be reset.

When the Total (N) reaches 999,999 the count resets automatically to 000.

All Meters

Page 26 of the Graco SDM5 user manual — Troubleshooting
Page 26 · click to enlarge
Page 26

Troubleshooting

  • Relieve pressure , page 9, before you check or repair the meter. Be sure all other valves, controls and pump are operating properly.
  • When calling for Technical Assistance you may be asked to provide the Software Version that is being used by your meter. Refer to F IG . 10, page 13, item #1 for help determining where this information is shown on your meter.

Battery icon is blinking. Batteries are low. Replace batteries, page 29.

Batteries are defective. Replace batteries, page 29.

Electronic control is malfunctioning. Replace the electronic bezel assem- bly. (See Manual Meters Parts page 36 or Preset Meters Parts page 38 to identify which kit is required for your meter).

Display does not activate.

Cannot read display Contrast is set too high or too low to be viewed in work area

Adjust contrast. See Adjusting Screen Contrast Using LEFT or RIGHT ARROWS, page 12.

1. Relieve pressure , page 9.
2. Clean or replace filter. Order Filter Kit 255885.

Filter is clogged.

3. If the problem remains, contact your Graco distributor for repair or replacement.

Pump pressure is low. Increase pump pressure.

Twist lock nozzle not fully open. Aim nozzle into bucket or rag. Fully open nozzle.

Slow or no fluid flow.

Do not trigger meter when nozzle is closed! If you do accidentally trig- ger the meter with the nozzle closed, point nozzle into a waste bucket and open the nozzle to relieve pressure and expel built up fluid.

Shut-off valve is not fully open. Fully open shut-off valve.

Foreign material is jammed in the meter housing.

Contact your Graco distributor for repair or replacement.

Displayed dispensed amount is not accurate.

Unit needs to be calibrated for the fluid that is being dispensed.

Calibrate the meter for the fluid that is being dispensed. See Calibrate Screen, page 16.

Meter leaks from cover/control. Poor seal at metering cover cham- ber.

Contact your Graco distributor for repair or replacement.

Troubleshooting · Problem Cause Solution

Page 27 of the Graco SDM5 user manual — Troubleshooting
Page 27 · click to enlarge
Page 27

Preset Models only - Trigger does not reset sufficiently to dispense fluid.

Excessive dirt buildup is causing trip rod to stick.

Clean trip rod or replace (page 30). Order Kit 255889.

Meter leaks from twist lock nozzle.

Twist lock nozzle has a damaged seal.

Replace nozzle. See Step 1 in Instal- lation Procedure, page 11.

  • It is important to distinguish between the two causes of this problem. A new nozzle will NOT correct a fluid leak caused by a faulty valve.

Valve has damaged or obstructed seals.

Clean valve stem and o-rings or replace. Order Kit 255888.

Poor swivel/hose connection. Apply PTFE tape (leave a minimum 2 engaged threads uncovered for elec- trical continuity) or sealant to threads of hose and tighten the connection. See Step 3 in Installation Procedure, page 10.

Meter leaks from swivel.

Poor swivel/meter housing connec- tion.

Torque the fitting to 20-25 ft.-lbs.

Swivel seals have deteriorated and leak.

Replace swivel.

Unit does not stop dispensing when assumed preset amount is dis- pensed.

Valve is dirty. Clean valve.

Low battery. Replace batteries, page 29.

Solenoid not functioning (Preset only).

Replace solenoid.

Troubleshooting · Problem Cause Solution

Page 28 of the Graco SDM5 user manual — Error Codes
Page 28 · click to enlarge
Page 28

Error Codes

Error codes are listed below. Even in an error condition the unit keeps track of the amount dispensed. With any error code displayed you can:

  • Select Manual option on Home Screen.

Error code is cleared. Unit switches to Manual mode and dispensed amount is displayed.

  • Select reset option.

Error code is cleared, Unit switches to Auto mode and the present amount is displayed.

Error Code Cause Solution

Err 1 Battery voltage is low Change battery, page 29.

Ensure that your flow rate is not higher than 14 gpm (37.8 lpm). For further assistance, contact your Graco distributor.

Switch ErrorError occurred with pick-up in internal gear. or

Unit was dropped or unit encoun- tered excessive vibration during ship- ping.

Select Reset, item G, page 21.

Flow has continued after it should have shut off.

Check for low battery symbol and replace batteries if indicated, page 29. For further assistance, contact your Graco distributor.

Flow has occurred in lockout condi- tion.

Navigate to Home screen. Then re-enter Dispense Screen.

In Manual Mode only. The unit has dispensed the shut-off default amount and has stopped fluid flow.

Select Reset, item G, page 21 and dispense again.To change the shut-off default amount, see Units/Limits Screen, page 15.

A present dispense amount of zero was entered for the dispense or is stored as the default and a Preset dispense was attempted.

Enter an amount that is not zero. See Preset Dispense Screen, page 22.

Battery voltage is too low.

Change battery, page 29.

CAP ERROR: Error has occurred in control.

Replace the electronic bezel assem- bly. (See Manual Meters Parts page 36 or Preset Meters Parts page 38 to identify which kit is required for your meter).

Show 8 more labels / short text on this page
Troubleshooting · Err 2 · Err 4 · or · Err 5 · Err 6 · or · Err7
Page 29 of the Graco SDM5 user manual — Replacing the Battery
Page 29 · click to enlarge
Page 29

Service

See Parts List, page 43, for reference numbers included in the following Service instructions.

Replacing the Battery

Graco SDM5 — Replacing the Battery diagram (page 29)
Fig. 16 · Replacing the Battery
  • Only use the size and type of batteries specified in this manual.

Batteries required to meet life expectancy:

  • Energizer E91
  • Be sure to follow the correct polarity when installing batteries in the battery compartment (F IG . 28). Reversed batteries may damage this meter.
  • Do not mix different types of batteries together or old batteries with fresh ones. Always replace all 4 batteries with 4, fresh, new batteries.

The low battery and dead battery displays are explained in the Troubleshooting Table, page 26.

To change the battery:

4. Replace cover. The cover is designed to only fit on battery compartment one way. The notch (a) on cover fits into slot (b) on compartment. (F IG . 29).
1. Press firmly on battery compartment cover. Using a flat screwdriver turn latch screw counter-clockwise 1/2 turn.
Graco SDM5 — Replacing the Battery diagram (page 29)
Fig. 17 · Replacing the Battery
2. Remove the battery compartment cover and batteries.
3. Install new batteries. See F IG . 28 for battery orientation.
5. Press down firmly on cover. Using a flat screwdriver turn latch screw clockwise 1/2 turn.

Service · (b) · (a)

Page 30 of the Graco SDM5 user manual — Disassembly
Page 30 · click to enlarge
Page 30

Trip Rod Repair

4. With your finger, carefully lift up clip (D) to disconnect battery lead (B) from battery module.

(SDP5 & SDP15 Meters Only)

Graco SDM5 — Trip Rod Repair diagram (page 30)
Fig. 18 · Trip Rod Repair

Disassembly

1. Relieve Pressure , page 9.
2. Use a Torx (T20) wrench to remove 4 corner screws (A) located on the bottom of the meter (F IG . 30). Keep these screws for reassembly.
Graco SDM5 — Disassembly diagram (page 30)
Fig. 19 · Disassembly
Graco SDM5 — Disassembly diagram (page 30)
Fig. 20 · Disassembly

Do not use a screw driver or any other tool to lift up clip (D) when disconnecting battery lead (B) from bat- tery module. If the clip is damaged or broken it cannot be repaired; you will have to replace the battery mod- ule. Order Part No. 255197.

3. Turn meter over and tilt cover back (F IG . 31).

You will not be able to completely remove the cover until you disconnect the leads to the battery, sole- noid and remove the reed switch PCB.

5. Unsnap solenoid lead (C) (F IG . 33).
Graco SDM5 — Disassembly diagram (page 30)
Fig. 21 · Disassembly
Graco SDM5 — Disassembly diagram (page 30)
Fig. 22 · Disassembly

Service

Page 31 of the Graco SDM5 user manual — D
Page 31 · click to enlarge
Page 31
6. Remove two screws (D) holding reed switch board to the cover plate (F IG . 34). Keep these screws for reassembly. Remove cover assembly.

down and out of groove on housing (FIG. 36).

Graco SDM5 — Trip Rod Repair diagram (page 31)
Fig. 23 · Trip Rod Repair
Graco SDM5 — Trip Rod Repair diagram (page 31)
Fig. 24 · Trip Rod Repair

D

9. Unscrew solenoid (12) and remove from meter housing (F IG . 37). If necessary, a pliers can be used to loosen solenoid.
7. Remove and discard o-ring (5) (F IG . 35).
Graco SDM5 — D diagram (page 31)
Fig. 25
Graco SDM5 — D diagram (page 31)
Fig. 26
8. Remove guard (9) by inserting your thumb or finger behind the cover and pry it loose. Then slide guard

Service

Page 32 of the Graco SDM5 user manual — Cleaning Trip Rod
Page 32 · click to enlarge
Page 32
10. Place meter in a vise as shown in F IG . 38. Use new trip rod from your kit (2) or a non-metal rod or dowel to push trip rod through meter housing (F IG . 38 and F IG . 39) far enough to access pin (19) holding together trip rod and trigger.
13. Remove trip rod assembly from meter housing.

Be careful when you remove the trip rod assembly. Cover the balls with your fingers or a rag to prevent them from falling out.

Graco SDM5 — Trip Rod Repair diagram (page 32)
Fig. 27 · Trip Rod Repair
Graco SDM5 — Trip Rod Repair diagram (page 32)
Fig. 28 · Trip Rod Repair
Graco SDM5 — Trip Rod Repair diagram (page 32)
Fig. 29 · Trip Rod Repair

Cleaning Trip Rod

11. Use a pick to push pin (19) out (F IG . 39).

a. If the trigger does not reset sufficiently to dis- pense fluid, clean trip rod and spring with a soft brush and cleaning fluid such as mineral spirits.

Graco SDM5 — Cleaning Trip Rod diagram (page 32)
Fig. 30 · Cleaning Trip Rod

b. Inspect trip rod and spring. If damaged, replace using Trip Rod Replacement Kit 255889.

12. Remove trigger assembly (6) from meter housing.
Graco SDM5 — Cleaning Trip Rod diagram (page 32)
Fig. 31 · Cleaning Trip Rod

Service

Page 33 of the Graco SDM5 user manual — Reassembly
Page 33 · click to enlarge
Page 33

Reassembly

5. Install trigger assembly (8) (F IG . 44). Push pin (19) through holes in trigger and trip rod assembly.

Use all the new parts provided in the kit. Do not reuse the old parts.

Graco SDM5 — Reassembly diagram (page 33)
Fig. 32 · Reassembly
1. Insert balls (3) in trip rod (2) (F IG . 42).
2. Slide spring (1) over trip rod (2) (F IG . 42).
Graco SDM5 — Reassembly diagram (page 33)
Fig. 33 · Reassembly
6. Install solenoid (12). Finger tighten securely.
Graco SDM5 — Reassembly diagram (page 33)
Fig. 34 · Reassembly
3. Insert trip rod assembly in opening in meter housing (F IG . 43).
Graco SDM5 — Reassembly diagram (page 33)
Fig. 35 · Reassembly
7. Install o-ring (5).
Graco SDM5 — Reassembly diagram (page 33)
Fig. 36 · Reassembly
4. Turn meter over and place in vise. Align holes in trigger assembly with holes in trip rod (2). Use the old trip rod or a non-metal rod or dowel to push trip rod up and out of the meter housing (F IG . 44) far enough to see hole for pin (19) to slide into, however, do not install pin in this step.

Service

Page 34 of the Graco SDM5 user manual — NOTICE
Page 34 · click to enlarge
Page 34
8. Reinstall reed switch board in meter housing. Use 2 screws (D) to secure reed switch PCB to cover plate. Tighten screws until they bottom out.

NOTICE

Do not use a screw driver or any other tool to lift up clip (D) when reconnecting battery lead (B). If the clip is damaged or broken it cannot be repaired; you will have to replace the battery module. Order Part No. 255197.

Graco SDM5 — NOTICE diagram (page 34)
Fig. 37
Graco SDM5 — NOTICE diagram (page 34)
Fig. 38

D

D

9. Reconnect lead (B) to battery by carefully sliding connector over battery terminals (E) until it snaps securely into place under clip (D) (F IG . 48).
10. Reconnect solenoid lead (C) (F IG . 49).
Graco SDM5 — D diagram (page 34)
Fig. 39
Graco SDM5 — D diagram (page 34)
Fig. 40

E D

11. Position cover over meter housing.

NOTICE

When replacing cover, be careful not to pinch wires.

Service · ti11938ab

Page 35 of the Graco SDM5 user manual — A
Page 35 · click to enlarge
Page 35
12. Replace 4 screws (A). Torque each to 15-25 inch pounds.
Graco SDM5 — Trip Rod Repair diagram (page 35)
Fig. 41 · Trip Rod Repair

A

A

13. Install guard (9).
Graco SDM5 — A diagram (page 35)
Fig. 42

Service

Page 36 of the Graco SDM5 user manual — SDM5 & SDM15 Manual Meters Parts
Page 36 · click to enlarge
Page 36

SDM5 & SDM15 Manual Meters Parts

SDM5 & SDM15 Manual Meters Parts

Ref Part Description Qty 2 115477 SCREW, mach, torx pan hd 6 5 120812 O-RING, seal 1 6 15K418 TRIGGER, meter 1 9 15K464 GUARD, bumper 1 11 HOUSING, meter 1 17 255197 MODULE, battery 1 18 256493 KIT, repair, electronic bezel, includes 18a and instruction man- ual 312942 18a LABEL, control, overlay 1 19 120850 PIN, dowel M4 2 24 255888 KIT, repair, seals and spring only includes 24a-24d and instruction manual 312939 16F811 KIT, repair, valve, spring and seals includes 24a-24f and instruction manual 312939 24a PACKING, o-ring 1 24b PACKING, o-ring 1 24c O-RING, 3 24d SPRING, compression 6.1 x 76mm 1 24e CARTRIDGE, valve 1 24f STEM, valve 1 28 120853 PIN, dowel 1 31 247344 SWIVEL, straight, 1/2-14 NPT, includes 31a (used with 255348, 255349, 255350, 255802, 255803, 255804, 256836, 256837)

Ref Part Description Qty

32 15T366 BOOT, swivel, 3/4” hose, black, NPT, BSPT (standard with meter)

15T367 BOOT, swivel, 3/4” hose, red, NPT, BSPT

15T368 BOOT, swivel, 3/4” hose, blue, NPT, BSPT

15T369 BOOT, swivel, 3/4” hose, green, NPT, BSPT

15T370 BOOT, swivel, 3/4” hose, yellow, NPT, BSPT

125961 BOOT, swivel, inlet, black, BSPP 1 126115 BOOT, swivel, inlet, red, BSPP 1 126116 BOOT, swivel, inlet, blue, BSPP 1 126117 BOOT, swivel, inlet, green, BSPP 1 126118 BOOT, swivel, inlet, yellow, BSPP 1 34 255885 KIT, filter, includes 34a-34c 1 34a FILTER, wire, 40 mesh 10 34b PACKING, o-ring 10 34c SPACER, strainer 10 39 15R057 BUSHING, stationary, rod 1 40 15R056 ROD, stationary 1 41 115999 RING, retaining 1 47 121413 BATTERY, pkg, 4 count, alkaline, AA (page 29)

49 15T259 LABEL, CE 1 50 15T492 SPACER, 1/4 OD x 0.9 th 4 51 15T603 GUARD, right 1 52 15T604 GUARD, left 1 53 117436 SCREW, thd forming 2

247345 SWIVEL, straight, 3/4-14 NPT includes 31a (used with 255800, 255801)

Replacement Danger and Warning labels, tags and cards are available at no cost.

24H098 SWIVEL, straight, 1/2-14 BSPP, includes 31a (used with 24H108, 224H110, 24H112, 24H130, 24H132, 24H150, 24H152)

24H100 SWIVEL, straight, 3/4-14 BSPP, includes 31a (used with 24H126, 24H128)

24H097 SWIVEL, straight, 1/2-14 BSPT, includes 31a (used with 24H109, 24H111, 24H113, 24H131, 24H133, 24H151, 24H153)

24H099 SWIVEL, straight, 3/4-14 BSPT includes 31a (used with 24H127, 24H129)

31a 105765 O-RING 1

(

Page 37 of the Graco SDM5 user manual — SDM5 & SDM15 Manual Meters Parts
Page 37 · click to enlarge
Page 37

SDM5 & SDM15 Manual Meters Parts

Graco SDM5 — SDM5 & SDM15 Manual Meters Parts diagram (page 37)
Fig. 43 · SDM5 & SDM15 Manual Meters Parts
Page 38 of the Graco SDM5 user manual — SDP5 & SDP 15 Preset Meters Parts
Page 38 · click to enlarge
Page 38

SDP5 & SDP 15 Preset Meters Parts

SDP5 & SDP 15 Preset Meters Parts

Ref Part Description Qty 2 115477 SCREW, mach, torx pan hd 6 3 255889 KIt, repair, trip rod, includes 3a-3c and instruction manual 312944

Ref Part Description Qty

31a 105765 O-RING 1 32 15T366 BOOT, swivel, 3/4” hose, black (standard with meter)

15T367 BOOT, swivel, 3/4” hose, red, NPT, BSPT

3a BALL,5 MM, carbide 3 3b ROD 1 3c SPRING, compression 10.67 mm 1 5 120812 O-RING, seal 1 6 15K418 TRIGGER, meter 1 7 15K443 ARM, trip 1 8 15K446 PLATE, ratchet 1 9 15K464 GUARD, bumper 1 11 HOUSING, meter 1 12 15W093 SOLENOID 1 15 15K602 SPRING, torsion 1 17 255197 MODULE, battery 1 18 256494 KIT, repair, electronic bezel, includes 18a and instruction man- ual 312942

15T368 BOOT, swivel, 3/4” hose, blue, NPT, BSPT

15T369 BOOT, swivel, 3/4” hose, green, NPT, BSPT

15T370 BOOT, swivel, 3/4” hose, yellow, NPT, BSPT

125961 BOOT, swivel, inlet, black, BSPP 1 126115 BOOT, swivel, inlet, red, BSPP 1 126116 BOOT, swivel, inlet, blue, BSPP 1 126117 BOOT, swivel, inlet, green, BSPP 1 126118 BOOT, swivel, inlet, yellow, BSPP 1 34 255885 KIT, filter, includes 34a-34c 1 34a KIT, filter, wire, 40 mesh 10 34b PACKING, o-ring 10 34c SPACER, strainer 10 47 121413 BATTERY, pkg, 4 count, alkaline, AA (page 29)

18a LABEL, control, overlay 1 19 120850 PIN, dowel M4 2 24 255888 KIT, repair, seals ands spring only, includes 24a-24d and instruction manual 312939 16F811 KIT, repair, valve and seal, includes 24a-24f and instruction manual 312939 24a PACKING, o-ring 1 24b PACKING, o-ring 1 24c PACKING, o-ring 3 24d SPRING, compression 6.1 x 76mm 1 24e CARTRIDGE, valve 1 24f STEM, valve 1 28 120853 PIN, dowel 1 31 247344 SWIVEL, straight, 1/2-14 NPT, includes 31a (used with 255200, 255351, 255352, 255355, 255356, 256838, 256839)

49 15T259 LABEL, CE 1 51 15T603 GUARD, right 1 52 15T604 GUARD, left 1 53 117436 SCREW, thd forming 2

Replacement Danger and Warning labels, tags and

cards are available at no cost.

247345 SWIVEL, straight, 3/4-14 NPT includes 31a (used with 255353, 255354)

24H098 SWIVEL, straight, 1/2-14 BSPP, includes 31a (used with 24H106, 224H114, 24H116, 24H122, 24H124, 24H154, 24H156)

24H100 SWIVEL, straight, 3/4-14 BSPP, includes 31a (used with 24H118, 24H120)

24H097 SWIVEL, straight, 1/2-14 BSPT, includes 31a (used with 24H107, 24H115, 24H117, 24H123, 24H125, 24H155, 24H157)

24H099 SWIVEL, straight, 3/4-14 BSPT includes 31a (used with 24H119, 24H121)

(

Page 39 of the Graco SDM5 user manual — SDP5 & SDP 15 Preset Meters Parts
Page 39 · click to enlarge
Page 39

SDP5 & SDP 15 Preset Meters Parts

Graco SDM5 — SDP5 & SDP 15 Preset Meters Parts diagram (page 39)
Fig. 44 · SDP5 & SDP 15 Preset Meters Parts
Page 40 of the Graco SDM5 user manual — Nozzle (33) and Extension (20) Kits
Page 40 · click to enlarge
Page 40

Nozzle (33) and Extension (20) Kits

Nozzle (33) and Extension (20) Kits

Part No. Description Fluid Type

Graco SDM5 — Nozzle (33) and Extension (20) Kits diagram (page 40)
Fig. 45 · Nozzle (33) and Extension (20) Kits

255852* Automatic, non-drip quick close nozzle with rigid extension. Oil

Graco SDM5 — Nozzle (33) and Extension (20) Kits diagram (page 40)
Fig. 46 · Nozzle (33) and Extension (20) Kits

255853* Automatic, non-drip quick close nozzle with flexible extension Oil

Graco SDM5 — Nozzle (33) and Extension (20) Kits diagram (page 40)
Fig. 47 · Nozzle (33) and Extension (20) Kits

255854 Non-drip, quick close nozzle with rigid extension Gear Lube

Graco SDM5 — Nozzle (33) and Extension (20) Kits diagram (page 40)
Fig. 48 · Nozzle (33) and Extension (20) Kits

255855* Non-drip, quick close nozzle with rigid exten- sion Anti-freeze

Graco SDM5 — Nozzle (33) and Extension (20) Kits diagram (page 40)
Fig. 49 · Nozzle (33) and Extension (20) Kits

255856* Non-drip, quick close nozzle with flexible extension Anti-freeze

*Used for dispensing 5gpm (22.7 lpm) or less.

Show 10 more labels / short text on this page
ti11827 · ti11826 · ti11827 · ti11825 · ti11830 · ti11831 · ti11828 · ti11826 · ti11828 · ti11825
Page 41 of the Graco SDM5 user manual — Nozzle (33) and Extension (20) Kits
Page 41 · click to enlarge
Page 41

Nozzle (33) and Extension (20) Kits

Part No. Description Fluid Type

255857 Non-drip, quick close, high-flow nozzle with rigid extension

Graco SDM5 — Nozzle (33) and Extension (20) Kits diagram (page 41)
Fig. 50 · Nozzle (33) and Extension (20) Kits

255858 Non-drip, quick close, high flow nozzle with flexible extension

Show 6 more labels / short text on this page
Oil and Anti-freeze · ti11829 · ti11826 · Oil and Anti-freeze · ti11829 · ti11825
Page 42 of the Graco SDM5 user manual — Thermal Relief Kits (page 8)
Page 42 · click to enlarge
Page 42

Nozzle (33) and Extension (20) Kits

Nozzle (33) Kits

255459* Automatic, non-drip, quick-close nozzle Qty Oil

  • BODY, nozzle 1
  • O-RING, packing 1
  • SPRING, compression 1
  • O-RING, packing 1
  • STEM, nozzle, valve 1
  • SEAT, valve 1

255460* Automatic, non-drip, quick-close nozzle Anti-freeze

  • BODY, nozzle 1
  • SPRING, compression 1
  • O-RING, packing 1
  • STEM, nozzle, valve 1
  • O-RING, packing 1
  • SEAT, valve 1

255461 Automatic, non-drip, high-flow nozzle Oil and Antifreeze

  • STEM, nozzle 1
  • BODY, nozzle 1
  • O-RING, packing 1
  • O-RING, packing 1
  • O-RING, packing 1

255470 Non-drip, quick-close nozzle Gear Lube

  • Housing 1
  • Body, nozzle 1
  • O-RING, packing 1
  • O-RING, packing 1
  • Plug, Hollow, hex 1

*Used for dispensing 5gpm (22.7 lpm) or less.

Thermal Relief Kits (page 8)

Part No. Description PSI (bar) Rating 112353 Diaphragm pump for fuel dispense, valve only 50 psi (.34 MPa, 3.4 bar) 235998 Mini Fire-Ball™ 225, 3:1 600 psi (4.1 MPa, 41 bar) 237601 Fire-Ball 425, 3:1 600 psi (4.1 MPa, 41 bar) 237893 Fire-Ball 300, 5:1 900 psi (6.2 MPa, 62 bar) 248296 Fire-Ball 300, 5:1 (same as 237893 without bung adapter and swivel. Includes 6-foot hose)

900 psi (6.2 MPa, 62 bar)

238899 Diaphragm pump 150 psi (1 MPa, 10.4 bar) 240429 Fire-Ball 425, 6:1 and 10:1 1600 psi (11 MPa, 110 bar) 248324 Fire-Ball 425, 6:1 and 10:1 (same as 240429 minus bung adapter and swivel. Includes 6-foot hose)

1600 psi (11 MPa, 110 bar)

Page 43 of the Graco SDM5 user manual — Technical Data
Page 43 · click to enlarge
Page 43

Technical Data

Flow range* 0.26 to 14 gpm (1 to 53 lpm) Maximum Working Pressure 1500 psi (10 MPa, 103.4 bar) Maximum Working Pressure

(50:50 antifreeze/water mix) 900 psi (6.2 MPa, 62 bar) Units of Measure pints, quarts, gallons, liters (factory set to quarts) Weight 5 pounds (2.26 kg) Dimensions (without extension)

Length 13 inches (33 cm) Width 3.75 inches (9.5 cm) Height 5.75 inches (14.6 cm) Units of measure factory set in quarts maximum totalizer amount = 999,999 gallons or liters maximum recorded dispensed volume = 999.99 units

maximum preset volume (Preset only) = 999.9 units Inlet 1/2-14 npt or 3/4-14 npt, or 1/2-14 BSPP or 3/4-14 BSPP,

or 1/2-14 BSPT or 3/4-14 BSPT Outlet 3/4-16 straight thread o-ring boss Operating temperature range 4 °F to 158°F (-16°C to 70°C) Storage temperature range -40°F to 158°F (-40°C to 70°C) Battery** 4AA alkaline or lithium batteries Expected battery life in typical shop

Wetted parts aluminum, stainless steel, PBT/PC, zinc,

nitrile rubber, CS Fluid compatibility antifreeze, gear oil, crankcase oil, ATF Meter pressure loss 80 psi @ 10 gpm Accuracy† +/- 0.5 percent

*Tested in 10W motor oil. Flow rates vary with fluid pressure, temperature and viscosity.

**Battery required to meet life expectancy: Energizer® Alkaline E91.

† At 2.5 gpm (9.5 lpm), at 70°F (21°C), with 10-weight oil and 1 gallon dispensed. May require calibration; out-of-box accuracy is +/- 1.25 percent.

Technical Data · 1 year · environment

Page 44 of the Graco SDM5 user manual — Graco Information
Page 44 · click to enlarge
Page 44

Graco Extended Metered Dispense Valve Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. Graco will, for a period of five (5) years from the date of sale, repair or replace any non-electronic part of the equipment determined by Graco to be defective. Graco will also for a period of three (3) years from the date of sale, repair, or replace any meter electronic components determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents

Original instructions. This manual contains English. MM 312865

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA

Copyright 2008 Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com Revised December 2014

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
Err 1Battery voltage is lowChange battery, page 29. p.28
Err 2Switch Error: Error occurred with pick-up in internal gear. or Unit was dropped or unit encoun- tered excessive vibration during ship- ping.Ensure that your flow rate is not higher than 14 gpm (37.8 lpm). For further assistance, contact your Graco distributor. Select Reset, item G, page 21. p.28
Err 4Flow has continued after it should have shut off. or Flow has occurred in lockout condi- tion.Check for low battery symbol and replace batteries if indicated, page 29. For further assistance, contact your Graco distributor. Navigate to Home screen. Then re-enter Dispense Screen. p.28
Err 5In Manual Mode only. The unit has dispensed the shut-off default amount and has stopped fluid flow.Select Reset, item G, page 21 and dispense again.To change the shut-off default amount, see Units/Limits Screen, page 15. p.28
Err 6A present dispense amount of zero was entered for the dispense or is stored as the default and a Preset dispense was attempted.Enter an amount that is not zero. See Preset Dispense Screen, page 22. p.28
Err7Battery voltage is too low. or CAP ERROR: Error has occurred in control.Change battery, page 29. Replace the electronic bezel assem- bly. (See Manual Meters Parts page 36 or Preset Meters Parts page 38 to identify which kit is required for your meter). p.28
Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Battery icon is blinking.Batteries are low.Replace batteries, page 29. p.26
Display does not activate.Batteries are defective.Replace batteries, page 29. p.26
Display does not activate.Electronic control is malfunctioning.Replace the electronic bezel assem- bly. (See Manual Meters Parts page 36 or Preset Meters Parts page 38 to identify which kit is required for your meter). p.26
Cannot read displayContrast is set too high or too low to be viewed in work areaAdjust contrast. See Adjusting Screen Contrast Using LEFT or RIGHT ARROWS, page 12. p.26
Slow or no fluid flow.Filter is clogged.1. Relieve pressure, page 9. 2. Clean or replace filter. Order Fil- ter Kit 255885. 3. If the problem remains, contact your Graco distributor for repair or replacement. p.26
Slow or no fluid flow.Pump pressure is low.Increase pump pressure. p.26
Slow or no fluid flow.Twist lock nozzle not fully open.Aim nozzle into bucket or rag. Fully open nozzle. Do not trigger meter when nozzle is closed! If you do accidentally trig- ger the meter with the nozzle closed, point nozzle into a waste bucket and open the nozzle to relieve pressure and expel built up fluid. p.26
Slow or no fluid flow.Shut-off valve is not fully open.Fully open shut-off valve. p.26
Slow or no fluid flow.Foreign material is jammed in the meter housing.Contact your Graco distributor for repair or replacement. p.26
Displayed dispensed amount is not accurate.Unit needs to be calibrated for the fluid that is being dispensed.Calibrate the meter for the fluid that is being dispensed. See Calibrate Screen, page 16. p.26
Meter leaks from cover/control.Poor seal at metering cover cham- ber.Contact your Graco distributor for repair or replacement. p.26
Preset Models only - Trigger does not reset sufficiently to dispense fluid.Excessive dirt buildup is causing trip rod to stick.Clean trip rod or replace (page 30). Order Kit 255889. p.27
Meter leaks from twist lock nozzle. • It is important to distinguish between the two causes of this problem. A new nozzle will NOT correct a fluid leak caused by a faulty valve.Twist lock nozzle has a damaged seal.Replace nozzle. See Step 1 in Instal- lation Procedure, page 11. p.27
Meter leaks from twist lock nozzle. • It is important to distinguish between the two causes of this problem. A new nozzle will NOT correct a fluid leak caused by a faulty valve.Valve has damaged or obstructed seals.Clean valve stem and o-rings or replace. Order Kit 255888. p.27
Meter leaks from swivel.Poor swivel/hose connection.Apply PTFE tape (leave a minimum 2 engaged threads uncovered for elec- trical continuity) or sealant to threads of hose and tighten the connection. See Step 3 in Installation Procedure, page 10. p.27
Meter leaks from swivel.Poor swivel/meter housing connec- tion.Torque the fitting to 20-25 ft.-lbs. p.27
Meter leaks from swivel.Swivel seals have deteriorated and leak.Replace swivel. p.27
Unit does not stop dispensing when assumed preset amount is dis- pensed.Valve is dirty.Clean valve. p.27
Unit does not stop dispensing when assumed preset amount is dis- pensed.Low battery.Replace batteries, page 29. p.27
Unit does not stop dispensing when assumed preset amount is dis- pensed.Solenoid not functioning (Preset only).Replace solenoid. p.27

Ask about the Graco SDM5

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco SDM5

Be the first to ask — other owners or our team will answer.

Original document

Graco SDM5 manual PDF

44 pages·2.7 MB·Marine Instruments·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…