Volumetric Fluid Flow Meter
For precise metering of plural component fluids and solvents.
See page 2 for model information, including maximum working pressure.

G3000 and G3000HR (Model 289813 with 90° Sensor Connector Shown)
9902471 Conforms to UL2279
Certified to CAN/CSA E79-0 CAN/CSA E79-11
EExia II A T3 ITS03ATEX21212 II 1 G
Intrinsically Safe for Hazardous Locations (Class I; Division 1; Group D) when used with an approved barrier only.
* CE mark approvals only apply to meters used as part of Graco ProMix, ProMix 2KS, and PrecisionMix II Systems.

Recognized Component · G250 and G250HR · * 0359

Models 2
Troubleshooting 8 Maintenance 9
Low Pressure Meters 2 High Pressure Meters 2 Warnings 3 Installation 5
Residue Build-up on the Meter Gears 9 Flushing 9 Cleaning or Servicing the Meter Chamber 10 Parts 11
Dust and Foreign Matter 5 Installing the Flow Meter 5 Grounding 6 Operation 7
Flow Meter Kits 11 Bare Meter Assemblies 12 Dimensions 15 Technical Data 16 Pressure Drop Curve 17 Graco Standard Warranty 18 Graco Information 18
Pressure Relief Procedure 7 Flow Meter Function 7 Recommended Usage 7 Flow Volume Range 7 Checking the Meter Accuracy 7
Low Pressure Meters
300 psi (2.1 MPa, 21 bar) Maximum Fluid Working Pressure
4000 psi (28 MPa, 280 bar) Maximum Fluid Working Pressure
Models

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.


Installing the Flow Meter
Refer to ANSI standards ISA-RP12.6, NEC Article 504 and the Canadian Electrical Code Appendix F.
Avoid having dust or foreign matter enter the flow meter by taking the following precautions:
Fluid Line Fluid Shutoff Valve
Check Valve Fluid Shutoff Valve on outlet side

Have a qualified electrician check the electrical grounding continuity between the flow meter sensor and a true earth ground; remove the cable connec- tor from the sensor and measure the resistance from the cable connector Pin B to true earth ground. Refer to FIG. 2.
If the resistance is greater than 25 ohms, check the cable ground connection. Refer to FIG. 2. Reconnect the ground sheath or replace the cable. Do not oper- ate the system until the problem is corrected.
a. Mount the meter to a grounded conductive sur- face, or
b. Connect the conductive fluid hose to the meter inlet and outlet, or
c. Connect a ground wire to the meter's M6 mounting holes.
A +10-30 Vdc Supply (red) B Ground (black) C Signal Out (white)
7379A
F IG . 2
Installation

Pressure Relief Procedure
Flow Volume Range
The G3000 and G250 meters flow volume range is 0.02-1.0 gal./min. (75-3800 cc/min.).
The G3000HR and G250HR meters flow volume range is 0.01-0.5 gal./min. (38-1900 cc/min.).
This is a positive displacement, gear flow meter. The gear flow meter is highly accurate, even with low flow rates. The fluid flowing through the meter rotates the gears. The gear tooth is picked up by a sensor device, which produces an impulse for every gear tooth passing by.
G3000 and G250: If the flow meter scale factor is not between 0.112-0.140 cc/pulse, follow the clean- ing procedure on page 10, then recalibrate the flow meter.
Do not exceed the maximum working pressure of your meter or any component or accessory in your system.
G3000HR and G250HR: If the flow meter scale fac- tor is not between 0.05-0.07 cc/pulse, follow the cleaning procedure on page 10, then recalibrate the flow meter.
Operation

Before servicing this equipment always make sure to relieve the pressure.
Troubleshooting

Flushing
If the meter is not installed in an instrinsically safe location, make sure the power is off or the electronic sensor is disconnected before wiping the outside of the meter clean with a cloth dampened in a compati- ble solvent or flushing the meter.
Flush the fluid supply line and meter fluid reservoir daily with a compatible solvent as instructed below.
Air purge is not recommended for any gear-type flow meter. Air purges do not provide the lubrication the meter gears require.
Residue build-up may cause the meter gears to bind or stop rotating, which decreases the meter accuracy and makes meter recalibration necessary. As more build-up occurs, recalibration is required more often.
The frequency that your meter requires cleaning depends on the type of fluid being used. Excessive resi- due build-up usually means that you are using improper cleaning solvents and/or cleaning sequences or pro- cesses.
Maintenance

Installing and servicing this equipment requires access to parts that may cause electric shock or other serious injury if the work is not performed properly. Do not install or service this equipment unless you are trained and qualified.
Use only genuine Graco replacement parts. Substitu- tion of components may impair intrinsic safety. This could result in a failure which causes serious injury and/or substantial property damage.
Maintenance

Flow Meter Kits, for ProMix 2KS Wall Fluid Panel
15V827 G3000HR Meter Kit

Ref. No. Part No. Description Qty
101 289813 METER, gear, G3000; used on 15V804; see page 12 1
289814 METER, gear, G3000HR; used on 15V827; see page 12
104 501867 VALVE, check 1 105 234628 HARNESS, cable, with connec- tor
106 114182 SCREW, machine, hex flange hd; M6 x 10; 16 mm
108 15U749 BRACKET, mounting 1 109 15U750 TUBE, assembly; sst; 1/2 in. (13 mm) OD tube x 1/4 npt
110 C19798 SCREW, cap, socket-hd; 1/4-20 x 3/8 in. (10 mm)
Parts · 101 104

289814 G3000HR Meter, with 90° sensor connector
Ref. No. Part No. Description Qty. 1 114100 SCREW, socket-hd; M4 x 55 mm long

2 249430 ELECTRONIC SENSOR 1 3 239719 GEAR METER ASSEMBLY; includes items 4-11; used on 289813
244291 GEAR METER ASSEMBLY; includes items 4-11; used on 289814
* Not a replacement part. Order item 3, gear meter assembly.
Item 3, Gear Meter Assembly includes items 4-11
Torque to 27-57 in-lb (3.1-6.4 N•m).
Torque to 140-170 in-lb (15.8-19.2 N•m).
Parts

244292 G3000HR Meter
1 1 Ref. No. Part No. Description Qty. 1 114100 SCREW, socket-hd; M4 x 55 mm long
2 239717 ELECTRONIC SENSOR 1 3 239719 GEAR METER ASSEMBLY; includes items 4-11; used on 239716
244291 GEAR METER ASSEMBLY; includes items 4-11; used on 244292
Item 3, Gear Meter Assembly includes items 4-11
* Not a replacement part. Order item 3, gear meter assembly.
Torque to 27-57 in-lb (3.1-6.4 N•m).
Torque to 140-170 in-lb (15.8-19.2 N•m).
Parts

249427 G250HR Meter
Ref. No. Part No. Description Qty. 1 111308 SCREW, cap, socket-hd 4 2 * HOUSING, upper 1 4 110588 O-RING; ptfe 1 5 239718 GEAR; used on 249426 2 244290 GEAR; used on 249427 2 6 192383 SHAFT, gear; used on 249426 2 197142 SHAFT, gear; used on 249427 2 7 192387 PIN, locating 2 8 * HOUSING, lower 1 11 15F866 SPACER 1 20 119839 SCREW, cap, socket-hd; M4x65 2 21 294430 ELECTRONIC SENSOR 1 22 249428 GEAR METER ASSEMBLY; includes items 1-11; used on 249426

249429 GEAR METER ASSEMBLY; includes items 1-11; used on 249427
Item 22, Gear Meter Assembly includes items 1-11
* Not a replacement part. Order item 22, gear meter assembly.
Torque to 27-57 in-lb (3.1-6.4 N•m).
Torque to 140-170 in-lb (15.8-19.2 N•m).
Parts


Mounting Holes (bottom view)

1.73 in. (43.94 mm)
Part Nos. 249426 and 249427


Maximum Fluid Working Pressure
4000 psi (28 MPa, 276 bar) 250 psi (1.72 MPa, 17.2 bar) Flow Range
G3000 and G3000HR G250 and G250HR
0.02-1.0 gal/min (75-3800 cc/min) 0.01-0.5 gal/min (38-1900 cc/min) Fluid Temperature Range 40-180°F (4-80°C) Maximum Ambient Temperature 180°F (80°C) Fluid Viscosity Range 20-3000 cps (see Pressure Drop Curve on page 17) Maximum Cable Length 200 ft (61 m) Flow Meter Inlet/Outlet 1/4 npt(f) Resolution
G3000 and G250 G3000HR and G250HR
0.119 cc/pulse 0.061 cc/pulse Accuracy +/- 0.5%* Supply Voltage 10-30 Vdc Intrinsic Safety Class I; Div. 1; Group D V max = 30 V I max = 15 mA Ci = 0.2 microfarads Li = 0 mH Approvals See front cover Wetted Parts 303 Stainless Steel, Tungsten Carbide, PTFE Weight
G3000 and G250 G3000HR and G250HR
G3000 and G3000HR G250 and G250HR
6 lb (2.7 kg) 2.6 lb (1.8 kg)
* For most commonly used coatings, the flow meter reading will be accurate to within +/- 0.5%. Accuracy will dimin- ish at low viscosities and low flow rates.
Technical Data

0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1
GAL/MIN
G3000HR/G250HR
GAL/MIN 0.0 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 308778
Copyright 1997, Graco Inc. is registered to I.S. EN ISO 9001
www.graco.com Revised 11/2008
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No flow volume displayed at monitor- ing unit. | Flow volume is too low to measure. | Increase flow volume. | p.8 |
| No flow volume displayed at monitor- ing unit. | Fluid is not flowing. | Repair. | p.8 |
| No flow volume displayed at monitor- ing unit. | Damaged cable. | Replace cable. | p.8 |
| No flow volume displayed at monitor- ing unit. | Improper input voltage to sensor. | Make sure input voltage is 10-30 Vdc. | p.8 |
| No flow volume displayed at monitor- ing unit. | Damaged sensor. | Replace sensor if it is malfunctioning. | p.8 |
| Fluid is not flowing. | Clogs in fluid line or in meter. | Clean fluid line and/or meter; see Maintenance on page 9. | p.8 |
| Fluid is not flowing. | Gears worn or damaged. | Repair meter; see Maintenance on page 9. | p.8 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.