EN
Graco logo
Official user manual

Graco G3000

18 pages·1.1 MB·Marine Instruments·PDF·ENDEFRITNLJA
Graco G3000
Table of Contents 12 sections Models · Warnings · Installation · Operation · … ShowHide
Page 1 of the Graco G3000 user manual — Instructions-Parts
Page 1 · click to enlarge
Page 1

Instructions-Parts

Volumetric Fluid Flow Meter

For precise metering of plural component fluids and solvents.

See page 2 for model information, including maximum working pressure.

Graco G3000 — Instructions-Parts diagram (page 1)
Fig. 1 · Instructions-Parts

G3000 and G3000HR (Model 289813 with 90° Sensor Connector Shown)

9902471 Conforms to UL2279

Certified to CAN/CSA E79-0 CAN/CSA E79-11

EExia II A T3 ITS03ATEX21212 II 1 G

Intrinsically Safe for Hazardous Locations (Class I; Division 1; Group D) when used with an approved barrier only.

* CE mark approvals only apply to meters used as part of Graco ProMix, ProMix 2KS, and PrecisionMix II Systems.

Graco G3000 — Instructions-Parts diagram (page 1)
Fig. 2 · Instructions-Parts

Recognized Component · G250 and G250HR · * 0359

Page 2 of the Graco G3000 user manual — High Pressure Meters
Page 2 · click to enlarge
Page 2

Contents

Models 2

Troubleshooting 8 Maintenance 9

Low Pressure Meters 2 High Pressure Meters 2 Warnings 3 Installation 5

Residue Build-up on the Meter Gears 9 Flushing 9 Cleaning or Servicing the Meter Chamber 10 Parts 11

Dust and Foreign Matter 5 Installing the Flow Meter 5 Grounding 6 Operation 7

Flow Meter Kits 11 Bare Meter Assemblies 12 Dimensions 15 Technical Data 16 Pressure Drop Curve 17 Graco Standard Warranty 18 Graco Information 18

Pressure Relief Procedure 7 Flow Meter Function 7 Recommended Usage 7 Flow Volume Range 7 Checking the Meter Accuracy 7

Models

Low Pressure Meters

300 psi (2.1 MPa, 21 bar) Maximum Fluid Working Pressure

Meter Part No.SeriesModelFlow Range 249426AG2500.02 to 1.0 gpm (75 to 3800 cc/min) 249427AG250HR0.01 to 0.5 gpm (38 to 1900 cc/min)

High Pressure Meters

4000 psi (28 MPa, 280 bar) Maximum Fluid Working Pressure

Meter Part No.SeriesModelFlow Range 239716AG30000.02 to 1.0 gpm (75 to 3800 cc/min) 244292AG3000HR0.01 to 0.5 gpm (38 to 1900 cc/min) 289813AG3000, with 90° sensor connector0.02 to 1.0 gpm (75 to 3800 cc/min) 289814AG3000HR, with 90° sensor connector0.01 to 0.5 gpm (38 to 1900 cc/min)

Models

Page 3 of the Graco G3000 user manual — Warnings
Page 3 · click to enlarge
Page 3

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point gun at anyone or at any part of the body. • Do not put your hand over the spray tip. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Do not spray without tip guard and trigger guard installed. • Engage trigger lock when not spraying. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present. • Ground all equipment in the work area. See Grounding instructions. • Use only grounded hoses. • Hold gun firmly to side of grounded pail when triggering into pail. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Keep a working fire extinguisher in the work area. SPECIAL CONDITIONS Equipment must comply with the following conditions to avoid a hazardous condition which can cause fire, explosion, or electric shock: • Never use the flow meter with an electrostatic gun isolation stand. • Keep liquids away from the electronic sensor device. • Do not service the electronic sensor. Return it to your Graco distributor for service. PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
Page 4 of the Graco G3000 user manual — Warnings
Page 4 · click to enlarge
Page 4
WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. • Always wear impervious gloves when spraying or cleaning equipment. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: • Protective eyewear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection
Page 5 of the Graco G3000 user manual — 7379A
Page 5 · click to enlarge
Page 5

Installation

Installing the Flow Meter

  • Flow volume can only be measured at the location where the flow meter is installed.
  • All electrical equipment must only be installed by a qualified electrician.
  • The Fluid Flow Meters are intrinsically safe for Class I; Division 1; Group D hazardous indoor (NEMA 1) locations when installed with an intrinsically safe power device and wiring.
  • Understand and follow your local code and safety regulations for hazardous location wiring of intrinsically safe circuits.

Refer to ANSI standards ISA-RP12.6, NEC Article 504 and the Canadian Electrical Code Appendix F.

Dust and Foreign Matter

  • Do not use more than 200 ft. (61 m) of cable.

Avoid having dust or foreign matter enter the flow meter by taking the following precautions:

  • Refer to F IG . 1 to locate and install the flow meter, connectors, and fluid shutoff valves. Install a check valve to prevent backflow. The arrows on the flow meter and check valve show the direction of fluid flow.
  • Thoroughly flush the fluid supply lines before installing the flow meter.
  • When installing fittings, make sure that no sealing tape overlaps into the inside of the pipe.
  • The shutoff valves allow you to isolate the meter for service.
  • Install a 100 mesh fluid filter upstream of the flow meter.
  • Refer to the Technical Data and Dimensions Drawings for dimension, inlet/outlet size, temperature and other specifications.

Fluid Line Fluid Shutoff Valve

Check Valve Fluid Shutoff Valve on outlet side

7379A

F IG . 1Typical Installation
Show 6 more labels / short text on this page
Installation · Cable · Electronic Sensor Device · Ground Sheath · Flow Meter · on outlet side
Page 6 of the Graco G3000 user manual — A B C
Page 6 · click to enlarge
Page 6

Grounding

1. Ground the flow meter by connecting a grounded cable to the sensor.

Have a qualified electrician check the electrical grounding continuity between the flow meter sensor and a true earth ground; remove the cable connec- tor from the sensor and measure the resistance from the cable connector Pin B to true earth ground. Refer to FIG. 2.

If the resistance is greater than 25 ohms, check the cable ground connection. Refer to FIG. 2. Reconnect the ground sheath or replace the cable. Do not oper- ate the system until the problem is corrected.

2. Always ground the fluid supply unit, using one of the following options:

a. Mount the meter to a grounded conductive sur- face, or

b. Connect the conductive fluid hose to the meter inlet and outlet, or

c. Connect a ground wire to the meter's M6 mounting holes.

3. Never use the flow meter with an electrostatic gun isolation stand.

A +10-30 Vdc Supply (red) B Ground (black) C Signal Out (white)

A B C

7379A

F IG . 2

Installation

Page 7 of the Graco G3000 user manual — Recommended Usage
Page 7 · click to enlarge
Page 7

Operation

Pressure Relief Procedure

Flow Volume Range

The G3000 and G250 meters flow volume range is 0.02-1.0 gal./min. (75-3800 cc/min.).

The G3000HR and G250HR meters flow volume range is 0.01-0.5 gal./min. (38-1900 cc/min.).

1. Shut off the fluid supply to the meter.
2. Shut off all electrical power to the fluid system.
3. Follow the Pressure Relief Procedure for your fluid system dispensing device.

Flow Meter Function

This is a positive displacement, gear flow meter. The gear flow meter is highly accurate, even with low flow rates. The fluid flowing through the meter rotates the gears. The gear tooth is picked up by a sensor device, which produces an impulse for every gear tooth passing by.

Checking the Meter Accuracy

1. To check the accuracy of the meter, turn your gun fan and atomizing air off, then trigger the fluid into a graduated cylinder; dispense at least 500 cc of fluid.
2. Measure the volume of fluid in the beaker in cubic-centimeters (cc) and read the volume on the flow meter monitor.

Recommended Usage

G3000 and G250: If the flow meter scale factor is not between 0.112-0.140 cc/pulse, follow the clean- ing procedure on page 10, then recalibrate the flow meter.

Do not exceed the maximum working pressure of your meter or any component or accessory in your system.

G3000HR and G250HR: If the flow meter scale fac- tor is not between 0.05-0.07 cc/pulse, follow the cleaning procedure on page 10, then recalibrate the flow meter.

  • See the Technical Data for fluid and ambient temperature limits.
  • Only use the flow meter with fluids that are compatible with the “Wetted Parts” listed in the Technical Data .

Operation

Page 8 of the Graco G3000 user manual — Troubleshooting
Page 8 · click to enlarge
Page 8

Troubleshooting

Before servicing this equipment always make sure to relieve the pressure.

ProblemCauseSolution No flow volume displayed at monitoring unit.Flow volume is too low to measure.Increase flow volume. Fluid is not flowing.Repair. Damaged cable.Replace cable. Improper input voltage to sensor.Make sure input voltage is 10-30 Vdc. Damaged sensor.Replace sensor if it is malfunctioning. Fluid is not flowing.Clogs in fluid line or in meter.Clean fluid line and/or meter; see Maintenance on page 9. Gears worn or damaged.Repair meter; see Maintenance on page 9.

Troubleshooting

Page 9 of the Graco G3000 user manual — Residue Build-up on the Meter Gears
Page 9 · click to enlarge
Page 9

Maintenance

Flushing

If the meter is not installed in an instrinsically safe location, make sure the power is off or the electronic sensor is disconnected before wiping the outside of the meter clean with a cloth dampened in a compati- ble solvent or flushing the meter.

Flush the fluid supply line and meter fluid reservoir daily with a compatible solvent as instructed below.

1. Follow the Pressure Relief Procedure , on page 7.
2. Connect the fluid line to the solvent supply unit.
3. Flush the meter until it is clean.
4. Follow the Pressure Relief Procedure , then disconnect the fluid line from the solvent supply unit.

Air purge is not recommended for any gear-type flow meter. Air purges do not provide the lubrication the meter gears require.

5. Reconnect the fluid line to the fluid (paint) supply.
6. Turn on the fluid supply.

Residue Build-up on the Meter Gears

7. Operate until the meter and fluid line are free of solvent.

Residue build-up may cause the meter gears to bind or stop rotating, which decreases the meter accuracy and makes meter recalibration necessary. As more build-up occurs, recalibration is required more often.

The frequency that your meter requires cleaning depends on the type of fluid being used. Excessive resi- due build-up usually means that you are using improper cleaning solvents and/or cleaning sequences or pro- cesses.

  • Check the meter routinely to develop the correct cleaning schedule.
  • Use the proper cleaning solvent for the fluid being metered.

Maintenance

Page 10 of the Graco G3000 user manual — Cleaning or Servicing the Meter Chamber
Page 10 · click to enlarge
Page 10

Cleaning or Servicing the Meter Chamber

7. Remove and inspect the gears and shafts. Clean the meter parts with solvent.
8. Reassemble the gears and shafts into the lower housing in the position they were removed from. Check the gears for free and easy rotation.

Installing and servicing this equipment requires access to parts that may cause electric shock or other serious injury if the work is not performed properly. Do not install or service this equipment unless you are trained and qualified.

9. Make sure the two locating pins are in place.
10. Assemble the two meter housings, making sure to keep them parallel to each other.
11. Install the screws. Tighten them oppositely and evenly, to 12 ft-lb (16 N•m). Do not over-tighten.

Use only genuine Graco replacement parts. Substitu- tion of components may impair intrinsic safety. This could result in a failure which causes serious injury and/or substantial property damage.

12. After re-assembling the meter, test the gear rotation by applying a brief air blast to the meter inlet. You should clearly hear the gears spin.
13. Set the electronic sensor on the upper housing and tighten the two screws hand-tight, about 3.5 ft-lb (4.7 N•m). Do not over-tighten.
1. Follow the Pressure Relief Procedure , on page 7. Then close the fluid shut-off valve on each side of the meter.
2. Disconnect the cable from the electronic sensor device.
3. Disconnect both fluid line fittings and remove the meter from the fluid line.
4. Loosen the two screws and remove the electronic sensor device from the flow meter upper housing. See the Parts drawings, pages 12-14.
5. Loosen the screws. Keep a few threads of two opposing bolts engaged to minimize the torque stress on the shafts when you separate the meter housings.
6. Hold onto the upper housing and gently tap the opposing bolts to separate the lower housing.

Maintenance

Page 11 of the Graco G3000 user manual — 15V804 G3000 Meter Kit
Page 11 · click to enlarge
Page 11

Parts

Flow Meter Kits, for ProMix 2KS Wall Fluid Panel

15V804 G3000 Meter Kit

15V827 G3000HR Meter Kit

Graco G3000 — 15V804 G3000 Meter Kit diagram (page 11)
Fig. 3 · 15V804 G3000 Meter Kit

Ref. No. Part No. Description Qty

101 289813 METER, gear, G3000; used on 15V804; see page 12 1

289814 METER, gear, G3000HR; used on 15V827; see page 12

104 501867 VALVE, check 1 105 234628 HARNESS, cable, with connec- tor

106 114182 SCREW, machine, hex flange hd; M6 x 10; 16 mm

108 15U749 BRACKET, mounting 1 109 15U750 TUBE, assembly; sst; 1/2 in. (13 mm) OD tube x 1/4 npt

110 C19798 SCREW, cap, socket-hd; 1/4-20 x 3/8 in. (10 mm)

Parts · 101 104

Page 12 of the Graco G3000 user manual — 289813 G3000 Meter, with 90° sensor connector
Page 12 · click to enlarge
Page 12

Bare Meter Assemblies

289813 G3000 Meter, with 90° sensor connector

289814 G3000HR Meter, with 90° sensor connector

Ref. No. Part No. Description Qty. 1 114100 SCREW, socket-hd; M4 x 55 mm long

Graco G3000 — 289813 G3000 Meter, with 90° sensor connector diagram (page 12)
Fig. 4 · 289813 G3000 Meter, with 90° sensor connector

2 249430 ELECTRONIC SENSOR 1 3 239719 GEAR METER ASSEMBLY; includes items 4-11; used on 289813

244291 GEAR METER ASSEMBLY; includes items 4-11; used on 289814

  • 4 110580
  • SCREW 12 5 *
  • HOUSING, upper 1 7 110588
  • O-RING; ptfe 1 8 239718
  • GEAR; used on 289813 2 244290
  • GEAR; used on 289814 2 9 192383
  • SHAFT, gear; used on 289813 2 197142
  • SHAFT, gear; used on 289814 2 10 192387
  • PIN, locating 2 11 *
  • HOUSING, lower 1

* Not a replacement part. Order item 3, gear meter assembly.

Item 3, Gear Meter Assembly includes items 4-11

Torque to 27-57 in-lb (3.1-6.4 N•m).

Torque to 140-170 in-lb (15.8-19.2 N•m).

Parts

Page 13 of the Graco G3000 user manual — 239716 G3000 Meter
Page 13 · click to enlarge
Page 13

239716 G3000 Meter

244292 G3000HR Meter

1 1 Ref. No. Part No. Description Qty. 1 114100 SCREW, socket-hd; M4 x 55 mm long

2 239717 ELECTRONIC SENSOR 1 3 239719 GEAR METER ASSEMBLY; includes items 4-11; used on 239716

244291 GEAR METER ASSEMBLY; includes items 4-11; used on 244292

  • 4 110580
  • SCREW 12 5 *
  • HOUSING, upper 1 7 110588
  • O-RING; ptfe 1 8 239718
  • GEAR; used on 239716 2 244290
  • GEAR; used on 244292 2 9 192383
  • SHAFT, gear; used on 239716 2 197142
  • SHAFT, gear; used on 244292 2 10 192387
  • PIN, locating 2 11 *
  • HOUSING, lower 1

Item 3, Gear Meter Assembly includes items 4-11

* Not a replacement part. Order item 3, gear meter assembly.

Torque to 27-57 in-lb (3.1-6.4 N•m).

Torque to 140-170 in-lb (15.8-19.2 N•m).

Parts

Page 14 of the Graco G3000 user manual — 249426 G250 Meter
Page 14 · click to enlarge
Page 14

249426 G250 Meter

249427 G250HR Meter

Ref. No. Part No. Description Qty. 1 111308 SCREW, cap, socket-hd 4 2 * HOUSING, upper 1 4 110588 O-RING; ptfe 1 5 239718 GEAR; used on 249426 2 244290 GEAR; used on 249427 2 6 192383 SHAFT, gear; used on 249426 2 197142 SHAFT, gear; used on 249427 2 7 192387 PIN, locating 2 8 * HOUSING, lower 1 11 15F866 SPACER 1 20 119839 SCREW, cap, socket-hd; M4x65 2 21 294430 ELECTRONIC SENSOR 1 22 249428 GEAR METER ASSEMBLY; includes items 1-11; used on 249426

Graco G3000 — 249426 G250 Meter diagram (page 14)
Fig. 5 · 249426 G250 Meter

249429 GEAR METER ASSEMBLY; includes items 1-11; used on 249427

Item 22, Gear Meter Assembly includes items 1-11

* Not a replacement part. Order item 22, gear meter assembly.

Torque to 27-57 in-lb (3.1-6.4 N•m).

Torque to 140-170 in-lb (15.8-19.2 N•m).

Parts

Page 15 of the Graco G3000 user manual — M6
Page 15 · click to enlarge
Page 15

Dimensions

G250 and G250HR

Graco G3000 — G250 and G250HR diagram (page 15)
Fig. 6 · G250 and G250HR

Mounting Holes (bottom view)

Graco G3000 — G250 and G250HR diagram (page 15)
Fig. 7 · G250 and G250HR

M6

1.73 in. (43.94 mm)

Part Nos. 249426 and 249427

Graco G3000 — M6 diagram (page 15)
Fig. 8
Show 4 more labels / short text on this page
Dimensions · 1/4-18 npt(f) inlet/outlet · 1/4-18 npt(f) inlet/outlet · 1/4-18 npt(f) inlet/outlet
Page 16 of the Graco G3000 user manual — Technical Data
Page 16 · click to enlarge
Page 16

Technical Data

Maximum Fluid Working Pressure

4000 psi (28 MPa, 276 bar) 250 psi (1.72 MPa, 17.2 bar) Flow Range

G3000 and G3000HR G250 and G250HR

0.02-1.0 gal/min (75-3800 cc/min) 0.01-0.5 gal/min (38-1900 cc/min) Fluid Temperature Range 40-180°F (4-80°C) Maximum Ambient Temperature 180°F (80°C) Fluid Viscosity Range 20-3000 cps (see Pressure Drop Curve on page 17) Maximum Cable Length 200 ft (61 m) Flow Meter Inlet/Outlet 1/4 npt(f) Resolution

G3000 and G250 G3000HR and G250HR

0.119 cc/pulse 0.061 cc/pulse Accuracy +/- 0.5%* Supply Voltage 10-30 Vdc Intrinsic Safety Class I; Div. 1; Group D V max = 30 V I max = 15 mA Ci = 0.2 microfarads Li = 0 mH Approvals See front cover Wetted Parts 303 Stainless Steel, Tungsten Carbide, PTFE Weight

G3000 and G250 G3000HR and G250HR

G3000 and G3000HR G250 and G250HR

6 lb (2.7 kg) 2.6 lb (1.8 kg)

* For most commonly used coatings, the flow meter reading will be accurate to within +/- 0.5%. Accuracy will dimin- ish at low viscosities and low flow rates.

Technical Data

Page 17 of the Graco G3000 user manual — G3000/G250
Page 17 · click to enlarge
Page 17

Pressure Drop Curve

PSI

0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1

G3000/G250

GAL/MIN

G3000HR/G250HR

GAL/MIN 0.0 0.05 0.10 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55

Show 12 more labels / short text on this page
Pressure Drop Curve · 3000 cps · 2000 cps · 1500 cps · 1000 cps · 800 cps · 500 cps · 400 cps · 300 cps · 200 cps · 100 cps · 50 cps
Page 18 of the Graco G3000 user manual — GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Page 18 · click to enlarge
Page 18

Graco Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

This manual contains English. MM 308778

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441

Copyright 1997, Graco Inc. is registered to I.S. EN ISO 9001

www.graco.com Revised 11/2008

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
No flow volume displayed at monitor- ing unit.Flow volume is too low to measure.Increase flow volume. p.8
No flow volume displayed at monitor- ing unit.Fluid is not flowing.Repair. p.8
No flow volume displayed at monitor- ing unit.Damaged cable.Replace cable. p.8
No flow volume displayed at monitor- ing unit.Improper input voltage to sensor.Make sure input voltage is 10-30 Vdc. p.8
No flow volume displayed at monitor- ing unit.Damaged sensor.Replace sensor if it is malfunctioning. p.8
Fluid is not flowing.Clogs in fluid line or in meter.Clean fluid line and/or meter; see Maintenance on page 9. p.8
Fluid is not flowing.Gears worn or damaged.Repair meter; see Maintenance on page 9. p.8

Ask about the Graco G3000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco G3000

Be the first to ask — other owners or our team will answer.

Original document

Graco G3000 manual PDF

18 pages·1.1 MB·Marine Instruments·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…