ACETAL, POLYPROPYLENE, AND PVDF Husky 1040 Air-Operated Diaphragm Pumps

Graco DS2 — Instructions – Parts List diagram (page 1)
Fig. 1 · Instructions – Parts List

308443Z

Acetal Model Shown

120 psi (0.8 MPa, 8 bar) Maximum Fluid Working Pressure 120 psi (0.8 MPa, 8 bar) Maximum Air Input Pressure

*Model No. D71 Acetal Pumps ( certified) *Model No. D81 Acetal Pumps, Remote ( certified) *Model No. D72 Polypropylene Pumps *Model No. D82 Polypropylene Pumps, Remote *Model No. D75 PVDF Pumps *Model No. D85 PVDF Pumps, Remote *Model No. DR2 Polypropylene Plus Pumps *Model No. DS2 Polypropylene Plus Pumps, Remote *Model No. DR5 PVDF Plus Pumps *Model No. DS5 PVDF Plus Pumps, Remote

*NOTE: Refer to the Pump Matrix on page 24 to determine the Model No. of your pump. NOTE: Plus Models include stainless steel center sections.

Patent No. CN ZL94102643.4 FR 9408894 JA 3517270 US 5,368,452

Page 2 of the Graco DS2 user manual — INSTRUCTIONS
Page 2 · click to enlarge
Page 2

Table of Contents

Symbols

Safety Warnings 2 Installation 4 Operation 11 Maintenance 13 Troubleshooting 14 Service

Warning Symbol

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

Repairing the Air Valve 16 Ball Check Valve Repair 18 Diaphragm Repair 19 Bearing and Air Gasket Removal 22 Pump Matrix 24 Repair Kit Matrix 25 Parts 26 Torque Sequence 30 Dimensional Drawings 31 Technical Data and Performance Chart 32 Graco Standard Warranty 34 Graco Information 34

Caution Symbol

CAUTION

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

INSTRUCTIONS

This equipment is for professional use only.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not exceed the maximum working pressure of the lowest rated component in your system. This equipment has a 120 psi (0.8 MPa, 8 bar) maximum working pressure at 120 psi (0.8 MPa, 8 bar) maximum incoming air pressure.

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Do not use hoses to pull equipment.

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not ex- pose Graco hoses to temperatures above 82C (180F) or below –40C (–40F).

Do not lift pressurized equipment.

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

2 308443

Page 3 of the Graco DS2 user manual — FIRE AND EXPLOSION HAZARD
Page 3 · click to enlarge
Page 3

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

Pipe and dispose of the exhaust air safely, away from people, animals, and food handling areas. If the diaphragm fails, the fluid is exhausted along with the air. See Air Exhaust Ventilation on page 10.

To pump acids, always use a PVDF or a polypropylene pump. Take precautions to avoid acid or acid fumes from contacting the pump housing exterior. Stainless steel parts will be damaged by exposure to acid spills and fumes. Never use an acetal pump to pump acids.

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

Ground the equipment. Refer to Grounding on page 5.

Never use a polypropylene or PVDF pump with non-conductive flammable fluids as specified by your local fire protection code. Refer to Grounding on page 5 for additional information. Consult your fluid supplier to determine the conductivity or resistivity of your fluid.

If there is any static sparking or you feel an electric shock while using this equipment, stop pumping immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being pumped.

Pipe and dispose of the exhaust air safely, away from all sources of ignition. If the diaphragm fails, the fluid is exhausted along with the air. See Air Exhaust Ventilation on page 10.

Keep the work area free of debris, including solvent, rags, and gasoline.

Electrically disconnect all equipment in the work area.

Extinguish all open flames or pilot lights in the work area.

Do not smoke in the work area.

Do not turn on or off any light switch in the work area while operating or if fumes are present.

Do not operate a gasoline engine in the work area.

308443 3

Page 4 of the Graco DS2 user manual — General Information
Page 4 · click to enlarge
Page 4

Installation

General Information

Tightening Screws Before First Use

The Typical Installation shown in Fig. 2 is only a guide for selecting and installing system compo- nents. Contact your Graco distributor for assistance in planning a system to suit your needs.

Before using the pump for the first time, check and retorque all external fasteners. See Torque Se- quence, page 30. After the first day of operation, retorque the fasteners. Although pump use varies, a general guideline is to retorque fasteners every two months.

Always use Genuine Graco Parts and Accessories.

Reference numbers and letters in parentheses refer to the callouts in the figures and the parts lists on pages 26 to 27.

TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Read TOXIC FLUID HAZARD on page 3.

Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

4 308443

Page 5 of the Graco DS2 user manual — W
Page 5 · click to enlarge
Page 5

Installation

Grounding

Ground all of this equipment:

FIRE AND EXPLOSION HAZARD This pump must be grounded. Before operating the pump, ground the system as explained below. Also read the sec- tion FIRE AND EXPLOSION HAZARD on page 3.

Pump: Connect a ground wire and clamp as shown in Fig. 1. Loosen the grounding screw (W). Insert one end of a 12 ga (1.5 mm) minimum ground wire (Y) behind the grounding screw and tighten the screw securely. Connect the clamp end of the ground wire to a true earth ground. Order Part No. 222011 Ground Wire and Clamp.

The acetal pump contains stainless steel fibers which make the wetted parts conductive. Attaching the ground wire to the grounding screw will ground the air motor and the wetted parts.

The polypropylene and PVDF pumps are not conductive. Attaching the ground wire to the grounding screw will ground only the air motor. When pumping conductive flammable fluids, al- ways ground the entire fluid system by making sure the fluid system has an electrical path to a true earth ground (see Fig. 2). Never use a poly- propylene or PVDF pump with non-conductive flammable fluids as specified by your local fire protection code.

Y

US Code (NFPA 77 Static Electricity) recommends a conductivity greater than 50 x 10–12 Siemans/me- ter (mhos/meter) over your operating temperature range to reduce the hazard of fire. Consult your fluid supplier to determine the conductivity or resistivity of your fluid. The resistivity must be less than 2 x 1012 ohm-centimeters.

W

To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area. Check your local electrical code for detailed grounding instructions for your area and type of equipment.

Air and fluid hoses: Use only grounded hoses with a maximum of 500 ft (150 m) combined hose length to ensure grounding continuity.

Air compressor: Follow the manufacturer’s recom- mendations.

All solvent pails used when flushing: Follow the local code. Use only grounded metal pails, which are conductive. Do not place the pail on a non-con- ductive surface, such as paper or cardboard, which interrupts the grounding continuity.

Fluid supply container: Follow the local code.

308443 5

Page 6 of the Graco DS2 user manual — FLOOR MOUNT TYPICAL INSTALLATION
Page 6 · click to enlarge
Page 6

Installation

Air Line

b. Locate one bleed-type master air valve (B) close to the pump and use it to relieve trapped air. See the WARNING at left. Locate the other master air valve (E) upstream from all air line accessories and use it to isolate them during cleaning and repair.

A bleed-type master air valve (B) is required in your system to relieve air trapped between this valve and the pump. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury, including splashing in the eyes or on the skin, injury from moving parts, or contamination from hazardous fluids. See Fig. 2.

c. The air line filter (F) removes harmful dirt and moisture from the compressed air supply.

1. Install the air line accessories as shown in Fig. 2. Mount these accessories on the wall or on a bracket. Be sure the air line supplying the accessories is grounded.
2. Install a grounded, flexible air hose (A) between the accessories and the 1/2 npt(f) pump air inlet (N). See Fig. 2. Use a minimum 3/8” (10 mm) ID air hose. Screw an air line quick disconnect coupler (D) onto the end of the air hose (A), and screw the mating fitting into the pump air inlet snugly. Do not connect the coupler (D) to the fitting until you are ready to operate the pump.

a. Install an air regulator (C) and gauge to control the fluid pressure. The fluid outlet pressure will be the same as the setting of the air regulator.

KEY

A Air supply hose B Bleed-type master air valve (required for pump) C Air regulator D Air line quick disconnect E Master air valve (for accessories) F Air line filter G Fluid suction line H Fluid supply J Fluid drain valve (required) K Fluid shutoff valve L Fluid line N 1/2 npt(f) air inlet port R 1” fluid inlet port S 1” fluid outlet port Y Ground wire (required; see page 5 for installation instructions)

FLOOR MOUNT TYPICAL INSTALLATION

F B E C

A

D K L

S N

Y

H R

J

G

6 308443

Page 7 of the Graco DS2 user manual — Fluid Outlet Line
Page 7 · click to enlarge
Page 7

Installation

Mountings

Fluid Suction Line

If using a conductive (Acetal) pump, use conductive hoses (G). If using a non-conductive (polypropy- lene or PVDF) pump, ground the fluid system. See Grounding on page 5.

CAUTION

The pump exhaust air may contain contaminants. Ventilate to a remote area if the contaminants could affect your fluid supply. See Air Exhaust Ventilation on page 10.

The pump fluid inlet (R) is a 1” raised face flange. See Flange Connections on page 8.

If the fluid inlet pressure to the pump is more than 25% of the outlet working pressure, the ball check valves will not close fast enough, resulting in ineffi- cient pump operation.

1. Be sure the mounting surface can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.
2. For all mountings, be sure the pump is bolted directly to the mounting surface.

At inlet fluid pressures greater than 15 psi (104 kPa, 1 bar), diaphragm life will be shortened.

3. For ease of operation and service, mount the pump so the air valve cover (2), air inlet, and fluid inlet and outlet ports are easily accessible.

See the Technical Data on page 32 for maximum suction lift (wet and dry).

4. Rubber Foot Mounting Kit 236452 is available to reduce noise and vibration during operation.

Fluid Outlet Line

Installation of Remote Pilot Air Lines

1. Refer to Parts Drawings. Connect air line to pump as in preceding steps.

A fluid drain valve (J) is required to relieve pres- sure in the hose if it is plugged. The drain valve reduces the risk of serious injury, including splash- ing in the eyes or on the skin, or contamination from hazardous fluids when relieving pressure. Install the valve close to the pump fluid outlet. See Fig. 2.

2. Connect 1/4 in. O.D. tubing to push type connectors (14) on air motor of pump.
1. Use grounded fluid hoses (L). The pump fluid outlet (S) is a 1” raised face flange. Refer to Flange Connections on page 8.
3. Connect remaining ends of tubes to external air signal, such as Graco’s Cycleflo (P/N 195264) or Cycleflo II (P/N195265) controllers.
2. Install a fluid drain valve (J) near the fluid outlet. See the WARNING above.
3. Install a shutoff valve (K) in the fluid outlet line.

308443 7

Page 8 of the Graco DS2 user manual — R
Page 8 · click to enlarge
Page 8

Installation

Flange Connections

The fluid inlet and outlet ports are 1” raised face flanges. Connect 1” flanged plastic pipe to the pump as follows. You will need:

1. Place a lockwasher and a flat washer on each bolt. Refer to Fig. 3.
2. Align the holes in the gasket and the pipe flange with the holes in the pump flange.

One 4.25” diameter, 1/8” thick PTFE gasket, with four 0.62 diameter holes and a 1.15” diameter center

3. Lubricate the threads of the four bolts. Install the bolts through the holes and secure with the washers and nuts.

Four 1/2” x 2.5” bolts

Four 1/2” spring lockwashers

4. Hold the nuts with a wrench. Refer to the tightening sequence in Fig. 3 and torque the bolts to 10 to 15 ft-lb (14 to 20 N-m). Do not over-torque.

Eight 1/2” flat washers

Four 1/2” nuts.

BOLT TIGHTENING SEQUENCE

E F

S

A

D E

KEY A Flanged plastic pipe B PTFE gasket C Bolt D Lockwasher E Flat washer F Nut R 1” fluid inlet flange S 1” fluid outlet flange

R

Torque to 10 to 15 ft-lb (14-20 N-m). Do not over-torque.

Torque wrench · Adjustable wrench · 8 308443

Page 9 of the Graco DS2 user manual — P
Page 9 · click to enlarge
Page 9

Installation

Changing the Orientation of the Fluid Inlet and Outlet Ports

Fluid Pressure Relief Valve

The pump is shipped with the fluid inlet (R) and outlet (S) ports facing the same direction. See Fig. 4. To change the orientation of the inlet and/or outlet port:

CAUTION

Some systems may require installation of a pres- sure relief valve at the pump outlet to prevent overpressurization and rupture of the pump or hose. See Fig. 5.

1. Remove the screws (106 or 112) holding the inlet (102) and/or outlet (103) manifold to the covers (101).
2. Reverse the manifold and reattach. Install the screws (106 or 112). Torque the manifold screws to 80 to 90 in-lb (9 to 10 N-m). See Fig. 4. See Torque Sequence , page 30.

Thermal expansion of fluid in the outlet line can cause overpressurization. This can occur when using long fluid lines exposed to sunlight or ambi- ent heat, or when pumping from a cool to a warm area (for example, from an underground tank).

KEY

Overpressurization can also occur if the Husky pump is being used to feed fluid to a piston pump, and the intake valve of the piston pump does not close, causing fluid to back up in the outlet line.

N 1/2 npt(f) air inlet port P Muffler; air exhaust port is 3/4 npt(f) R 1” fluid inlet port S 1” fluid outlet port

101 Covers 102 Fluid inlet manifold 103 Fluid outlet manifold 106 Manifold screws 112 Manifold screws

Torque to 80 to 90 in-lb (9 to 10 N-m). See Torque Sequence, page 30.

KEY

R 1” fluid inlet port S 1” fluid outlet port V Pressure relief valve Part No. 112119 (stainless steel)

S

Install valve between fluid inlet and outlet ports.

N

2 Connect fluid inlet line here.

S Connect fluid outlet line here.

P

R

R

Acetal Model Shown · 308443 9

Page 10 of the Graco DS2 user manual — F B E C
Page 10 · click to enlarge
Page 10

Installation

Air Exhaust Ventilation

The air exhaust port is 3/4 npt(f). Do not restrict the air exhaust port. Excessive exhaust restriction can cause erratic pump operation.

FIRE AND EXPLOSION HAZARD Be sure to read FIRE OR EXPLOSION HAZARD and TOXIC FLUID HAZARD on page 3, before operating this pump.

To provide a remote exhaust:

1. Remove the muffler (P) from the pump air exhaust port.

Be sure the system is properly ventilated for your type of installation. You must vent the exhaust to a safe place, away from peo- ple, animals, food handling areas, and all sources of ignition when pumping flammable or hazardous fluids.

2. Install a grounded air exhaust hose (T) and connect the muffler (P) to the other end of the hose. The minimum size for the air exhaust hose is 3/4 in. (19 mm) ID. If a hose longer than 15 ft (4.57 m) is required, use a larger diameter hose. Avoid sharp bends or kinks in the hose. See Fig. 6.

Diaphragm failure will cause the fluid being pumped to exhaust with the air. Place an appropri- ate container at the end of the air exhaust line to catch the fluid. See Fig. 6.

3. Place a container (U) at the end of the air exhaust line to catch fluid in case a diaphragm ruptures.

VENTING EXHAUST AIR

KEY

A Air supply line B Bleed-type master air valve (required for pump) C Air regulator D Air line quick disconnect E Master air valve (for accessories) F Air line filter P Muffler T Grounded air exhaust hose U Container for remote air exhaust

F B E C

A

D

T

U

P

04168A

10 308443

Page 11 of the Graco DS2 user manual — Starting and Adjusting the Pump
Page 11 · click to enlarge
Page 11

Operation

Pressure Relief Procedure

1. Be sure the pump is properly grounded. Refer to Grounding on page 5.
2. Check all fittings to be sure they are tight. Be sure to use a compatible liquid thread sealant on all male threads. Tighten the fluid inlet and outlet fittings securely.

PRESSURIZED EQUIPMENT HAZARD The equipment stays pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray from the gun or splashing fluid, follow this procedure whenever you

3. Place the suction tube (if used) in the fluid to be pumped.

Are instructed to relieve pressure Stop pumping Check, clean, or service any system equipment Install or clean fluid nozzles

1. Shut off the air to the pump.
2. Open the dispensing valve, if used.
4. Place the end of the fluid hose (L) into an appropriate container.
3. Open the fluid drain valve to relieve all fluid pressure, having a container ready to catch the drainage.
5. Close the fluid drain valve (J). See Fig. 2.

Flush the Pump Before First Use

The pump was tested in water. If the water could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. Follow the steps under Starting and Adjusting the Pump.

6. With the pump air regulator (C) closed, open all bleed-type master air valves (B, E).
7. If the fluid hose has a dispensing device, hold it open while continuing with the following step.

Starting and Adjusting the Pump

8. Slowly open the air regulator (C) until the pump starts to cycle. Allow the pump to cycle slowly until all air is pushed out of the lines and the pump is primed.

TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. Do not lift a pump under pressure. If dropped, the fluid section may rupture. Always fol- low the Pressure Relief Procedure above before lifting the pump.

If you are flushing, run the pump long enough to thoroughly clean the pump and hoses. Close the air regulator. Remove the suction tube from the solvent and place it in the fluid to be pumped.

308443 11

Page 12 of the Graco DS2 user manual — Pump Shutdown
Page 12 · click to enlarge
Page 12

Operation

Operation of Remote Piloted Pumps

1. Follow preceding steps 1 through 7 of Starting and Adjusting Pump .
2. Open air regulator (C).

Pump Shutdown

The pump may cycle once before the external sig- nal is applied. Injury is possible. If pump cycles, wait until end before proceeding.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.

3. Pump will operate when air pressure is alternately applied and relieved to push type connectors (14).

At the end of the work shift, relieve the pressure.

12 308443

Page 13 of the Graco DS2 user manual — Flushing and Storage
Page 13 · click to enlarge
Page 13

Maintenance

Lubrication

Tightening Threaded Connections

The air valve is designed to operate unlubricated, however if lubrication is desired, every 500 hours of operation (or monthly) remove the hose from the pump air inlet and add two drops of machine oil to the air inlet.

Before each use, check all hoses for wear or damage, and replace as necessary. Check to be sure all threaded connections are tight and leak-free. Check fasteners. Tighten or retorque as necessary. Although pump use varies, a general guideline is to retorque fasteners every two months. See Torque Sequence, page 30.

CAUTION

Do not over-lubricate the pump. Oil is exhausted through the muffler, which could contaminate your fluid supply or other equipment. Excessive lubrica- tion can also cause the pump to malfunction.

Flushing and Storage

Preventive Maintenance Schedule

Flush the pump often enough to prevent the fluid you are pumping from drying or freezing in the pump and damaging it. Always flush the pump and follow the Pressure Relief Procedure on page 11 before storing it for any length of time. Use a compatible solvent.

Establish a preventive maintenance schedule, based on the pump’s service history. This is especially impor- tant for prevention of spills or leakage due to dia- phragm failure.

308443 13

Page 14 of the Graco DS2 user manual — PROBLEM CAUSE SOLUTION
Page 14 · click to enlarge
Page 14

Troubleshooting

1. Relieve the pressure before checking or servicing the equipment.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.

2. Check all possible problems and causes before disassembling the pump.

PROBLEM CAUSE SOLUTION

Pump cycles at stall or fails to hold pressure at stall.

Worn check valve balls (301), seats (201) or o-rings (202).

Replace. See page 18.

Pump will not cycle, or cycles once and stops.

Air valve is stuck or dirty. Disassemble and clean air valve. See pages 16 to 17. Use filtered air.

Check valve ball (301) severely worn and wedged in seat (201) or manifold (102 or 103).

Replace ball and seat. See page 18.

Check valve ball (301) is wedged into seat (201), due to overpressur- ization.

Install Pressure Relief Valve (see page 9).

Dispensing valve clogged. Relieve pressure and clear valve.

Pump operates erratically. Clogged suction line. Inspect; clear.

Sticky or leaking balls (301). Clean or replace. See page 18.

Diaphragm ruptured. Replace. See pages 19 to 21.

Restricted exhaust. Remove restriction.

Air bubbles in fluid. Suction line is loose. Tighten.

Diaphragm ruptured. Replace. See pages 19 to 21.

Loose inlet manifold (102), dam- aged seal between manifold and seat (201), damaged o-rings (202).

Tighten manifold bolts (106 or 112) or replace seats (201) or o-rings (202). See page 18.

Loose fluid side plate (105). Tighten or replace (pages 19 to 21).

Damaged o-ring (108). Replace. See pages 19 to 21.

14 308443

Page 15 of the Graco DS2 user manual — PROBLEM CAUSE SOLUTION
Page 15 · click to enlarge
Page 15

Troubleshooting

PROBLEM CAUSE SOLUTION

Fluid in exhaust air. Diaphragm ruptured. Replace. See pages 19 to 21.

Loose fluid side plate (105). Tighten or replace (pages 19 to 21).

Pump exhausts excessive air at stall.

Worn air valve block (7), o-ring (6), plate (8), pilot block (18), u-cups (10), or pilot pin o-rings (17).

Repair or replace. See pages 16 to 17.

Worn shaft seals (402). Replace. See pages 19 to 21.

Pump leaks air externally. Air valve cover (2) or air valve cover screws (3) are loose.

Tighten screws. See page 17.

Air valve gasket (4) or air cover gasket (22) is damaged.

Inspect; replace. See pages 16 to 17 and 22 to 23.

Air cover screws (25) are loose. Tighten screws. See pages 22 to 23.

Pump leaks fluid externally from ball check valves.

Loose manifolds (102, 103), dam- aged seal between manifold and seat (201), damaged o-rings (202).

Tighten manifold bolts (106 or 112) or replace seats (201) or o-rings (202). See page 18.

308443 15

Page 16 of the Graco DS2 user manual — Repairing the Air Valve
Page 16 · click to enlarge
Page 16

Service

Repairing the Air Valve

7. Clean all parts and inspect for wear or damage. Replace as needed. Reassemble as explained on page 17.

Torx (T20) screwdriver or 7 mm (9/32”) socket wrench

Lithium base grease

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.

Torque to 50–60 in-lb (5.6–6.8 N-m).

1. Relieve the pressure.
2. With a Torx (T20) screwdriver or 7 mm (9/32”) socket wrench, remove the six screws (3), air valve cover (2), and gasket (4). See Fig. 7.
3. Move the valve carriage (5) to the center position and pull it out of the cavity. Remove the valve block (7 ) and o-ring (6 ) from the carriage. Using a needle-nose pliers, pull the pilot block (18) straight up and out of the cavity. See Fig. 8.

See Detail at right.

Grease.

3 Grease lower face.

4. Pull the two actuator pistons (11) out of the bearings (12). Remove the u-cup packings (10) from the pistons. Pull the pilot pins (16) out of the bearings (15). Remove the o-rings (17) from the pilot pins. See Fig. 9.
5. Inspect the valve plate (8) in place. If damaged, use a Torx (T20) screwdriver or 7 mm (9/32”) socket wrench to remove the three screws (3). Remove the valve plate (8) and, on aluminum center housing models only, remove the seal (9). See Fig. 10.
6. Inspect the bearings (12, 15) in place. See Fig. 9. The bearings are tapered and, if damaged, must be removed from the outside. This requires disassembly of the fluid section. See page 22.
Show 10 more labels / short text on this page
Tools Required · Torque wrench · Needle-nose pliers · 4 · O-ring pick · Disassembly · 6 · 7 · 18 · 16 308443
Page 17 of the Graco DS2 user manual — Service
Page 17 · click to enlarge
Page 17

Service

Insert narrow end first.

1. If you removed the bearings (12, 15), install new ones as explained on page 22. Reassemble the fluid section.

Grease.

3 Install with lips facing narrow end of piston (11).

4 Insert wide end first.

2. On aluminum center housing models, install the valve plate seal (9 ) into the groove at the bottom of the valve cavity. The rounded side of the seal must face down into the groove. See Fig. 10.
3. Install the valve plate (8 ) in the cavity. On aluminum center housing models, the plate is reversible, so either side can face up. Install the three screws (3), using a Torx (T20) screwdriver or 7 mm (9/32”) socket wrench. Tighten until the screws bottom out on the housing. See Fig. 10.
4. Install an o-ring (17 ) on each pilot pin (16). Grease the pins and o-rings. Insert the pins into the bearings (15), narrow end first. See Fig. 9.
5. Install a u-cup packing (10 ) on each actuator piston (11), so the lips of the packings face the narrow end of the pistons. See Fig. 9.

3 Rounded side must face down (aluminum center housing models only). Tighten screws until they bottom out on the housing.

6. Lubricate the u-cup packings (10 ) and actuator pistons (11). Insert the actuator pistons in the bearings (12), wide end first. Leave the narrow end of the pistons exposed. See Fig. 9.
7. Grease the lower face of the pilot block (18 ) and install so its tabs snap into the grooves on the ends of the pilot pins (16). See Fig. 8.
8. Grease the o-ring (6 ) and install it in the valve block (7 ). Push the block onto the valve carriage (5). Grease the lower face of the valve block. See Fig. 8.
9. Install the valve carriage (5) so its tabs slip into the grooves on the narrow end of the actuator pistons (11). See Fig. 8.
10. Align the valve gasket (4 ) and cover (2) with the six holes in the center housing (1). Secure with six screws (3), using a Torx (T20) screwdriver or 7 mm (9/32”) socket wrench. Torque to 28 to 33 in-lb (3.2 to 3.7 N.m). See Fig. 7.
Show 6 more labels / short text on this page
Reassembly · 10 · 17 16 · 2 8 · 9 · 308443 17
Page 18 of the Graco DS2 user manual — A
Page 18 · click to enlarge
Page 18

Service

Ball Check Valve Repair

1. Clean all parts and inspect for wear or damage. Replace parts as needed.
2. Reassemble in the reverse order, following all notes in Fig. 11. Assemble the ball checks exactly as shown. The arrows (A) on the fluid covers (101) must point toward the outlet manifold (103).

10 mm socket wrench

Torque to 80 to 90 in-lb (9 to 10 N-m). See Torque Se- quence, page 30.

Arrow (A) must point toward outlet manifold (103).

3 Not used on some models.

4 Beveled seating surface must face ball (301).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.

A

1. Relieve the pressure. Disconnect all hoses.
2. Remove the pump from its mounting.
3. Using a 10 mm socket wrench, remove the four bolts (106) holding the outlet manifold (103) to the fluid covers (101). See Fig. 11.
4. Remove the seats (201), balls (301), and o-rings (202) from the manifold.
5. Turn the pump over and remove the inlet manifold (102). Remove the seats (201), balls (301), and o-rings (202) from the fluid covers (101).
Show 11 more labels / short text on this page
Reassembly · Tools Required · Torque wrench · O-ring pick · Disassembly · 201* 301* · 202* · 301* · 201* · 202* · 18 308443
Page 19 of the Graco DS2 user manual — A 2
Page 19 · click to enlarge
Page 19

Service

Diaphragm Repair

Disassembly NOTE: A Fluid Section Repair Kit is available. Refer to page 25 to order the correct kit for your pump. Parts included in the kit are marked with an asterisk, for example (401*). Use all the parts in the kit for the best results.

10 mm socket wrench

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.

19 mm open–end wrench

1. Relieve the pressure.
2. Remove the manifolds and disassemble the ball check valves as explained on page 18.
3. Using a 10 mm socket wrench, remove the screws (106 and 112) holding the fluid covers (101) to the air covers (23). Pull the fluid covers (101) off the pump. See Fig. 12.

You must torque the eight long screws (106) first, then the short screws (112). Torque to 130 to 150 in-lb (14 to 17 Nm). See Torque Sequence, page 30.

Arrow (A) must point toward air valve (B).

A 2

1 112 106 1

Show 6 more labels / short text on this page
Tools Required · Torque wrench · Adjustable wrench · O-ring pick · Lithium-base grease · 308443 19
Page 20 of the Graco DS2 user manual — Service
Page 20 · click to enlarge
Page 20

Service

4. Unscrew one outer plate (105) from the diaphragm shaft (24). Remove one diaphragm (401), and the inner plate (104). See Fig. 13.

Reassembly 1. Grease the shaft u-cup packings (402*) and install them so the lips face out of the housing (1). See Fig. 13.

2. Grease the length and ends of the diaphragm shaft (24), and slide it through the housing (1).
3. Assemble the inner diaphragm plates (104), diaphragms (401*), PTFE diaphragms (403*, if present), and outer diaphragm plates (105) exactly as shown in Fig. 13. These parts must be assembled correctly.
5. Pull the other diaphragm assembly and the diaphragm shaft (24) out of the center housing (1). Hold the shaft flats with a 19 mm open–end wrench, and remove the outer plate (105) from the shaft. Disassemble the remaining diaphragm assembly.
4. Apply medium-strength (blue) Loctite or equivalent to the threads of the fluid-side plates (105). Hold one of the outer plates (105) with a wrench, and torque the other outer plate to 20 to 25 ft-lb (27 to 34 N-m) at 100 rpm maximum. Do not over-torque.
6. Inspect the diaphragm shaft (24) for wear or scratches. If it is damaged, inspect the bearings (19) in place. If the bearings are damaged, refer to page 22.
5. Align the fluid covers (101) and the center housing (1) so the arrows (A) on the covers face the same direction as the air valve (B). Secure the covers with the screws (106 and 112), handtight. Place the bolt caps (113*) on the longer screws (106), and install the longer screws in the top and bottom holes of the covers. See Fig. 12.
7. Reach into the center housing (1) with an o-ring pick and hook the u-cup packings (402), then pull them out of the housing. This can be done with the bearings (19) in place.
6. First, torque the longer screws (106) oppositely and evenly to 130 to 150 in-lb (14 to 17 N m), using a 10 mm socket wrench. Then torque the shorter screws (112). See Torque Sequence , page 30.
8. Clean all parts and inspect for wear or damage. Replace parts as needed.
7. Reassemble the ball check valves and manifolds as explained on page 18.

20 308443

Page 21 of the Graco DS2 user manual — Service
Page 21 · click to enlarge
Page 21

Service

Graco DS2 — Service diagram (page 21)
Fig. 2 · Service

Cutaway View, with Diaphragms in Place Cutaway View, with Diaphragms Removed

Apply medium-strength (blue) Loctite or equiva- lent. Torque to 20 to 25 ft-lb (27 to 34 N-m) at 100 rpm maximum.

308443 21

Page 22 of the Graco DS2 user manual — Bearing and Air Gasket Removal
Page 22 · click to enlarge
Page 22

Service

Bearing and Air Gasket Removal

Tools Required Torque wrench

Reassembly 1. If removed, install the shaft u-cup packings (402*) so the lips face out of the housing (1).

10 mm socket wrench

2. The bearings (19, 12, and 15) are tapered and can only be installed one way. Insert the bearings into the center housing (1), tapered end first . Using a press or a block and rubber mallet, press-fit the bearing so it is flush with the surface of the center housing.

Press, or block and mallet

Disassembly NOTE: Do not remove undamaged bearings.

3. Reassemble the air valve as explained on page 17.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 11.

4. Align the new air cover gasket (22) so the pilot pin (16) protruding from the center housing (1) fits through the proper hole (H) in the gasket.
1. Relieve the pressure.
5. Align the air cover (23) so the pilot pin (16) fits in the middle hole (M) of the three small holes near the center of the cover. Apply medium-strength (blue) Loctite or equivalent to the threads of screws (25), and install the screws handtight. See Fig. 14. Using a 10 mm socket wrench, torque the screws oppositely and evenly to 130 to 150 in-lb (14 to 17 N m).
2. Remove the manifolds and disassemble the ball check valves as explained on page 18.
3. Remove the fluid covers and diaphragm assemblies as explained on page 19.
4. Disassemble the air valve as explained on page 16.
6. Install the diaphragm assemblies and fluid covers as explained on page 19.
5. Using a 10 mm socket wrench, remove the screws (25) holding the air covers (23) to the center housing (1). See Fig. 14.
7. Reassemble the ball check valves and manifolds as explained on page 18.
6. Remove the air cover gaskets (22). Always replace the gaskets with new ones.
7. Use a bearing puller to remove the diaphragm shaft bearings (19), air valve bearings (12) or pilot pin bearings (15). Do not remove undamaged bearings.
8. If you removed the diaphragm shaft bearings (19), reach into the center housing (1) with an o-ring pick and hook the u-cup packings (402), then pull them out of the housing. Inspect the packings. See Fig. 13.

Bearing puller · O-ring pick · 22 308443

Page 23 of the Graco DS2 user manual — H
Page 23 · click to enlarge
Page 23

Service

Insert bearings tapered end first.

Press-fit bearings flush with surface of center housing (1).

Apply medium-strength (blue) Loctite or equivalent. Torque to 130 to 150 in-lb (14 to 17 Nm).

Detail of Air Valve Bearings

H

M

308443 23

Page 24 of the Graco DS2 user manual — Pump Matrix
Page 24 · click to enlarge
Page 24

Pump Matrix

Husky 1040 Acetal, Polypropylene, and PVDF Pumps, Series A Your Model No. is marked on the pump’s serial plate. To determine the Model No. of your pump from the following matrix, select the six digits which describe your pump, working from left to right. The first digit is always D, designating Husky diaphragm pumps. The remaining five digits define the materials of construction. For example, a pump with an aluminum air motor, acetal fluid section, polypropylene seats, PTFE balls, and PTFE diaphragms is Model D 7 1 9 1 1. To order replacement parts, refer to the part lists on pages 26 to 27. The digits in the matrix do not correspond to the ref. nos. in the parts drawing and lists.

Graco DS2 — Pump Matrix diagram (page 24)
Fig. 3 · Pump Matrix

Diaphragm Pump Air Motor Fluid Section – Seats Balls Diaphragms

1 (acetal) – 1 (not used) 1 (PTFE) 1 (PTFE)

2 (polypropylene) – 2 (acetal) 2 (acetal) 2 (not used)

R SST (standard) 3 (not used) – 3 (316 sst) 3 (316 sst) 3 (not used)

S SST (remote) 4 (not used) – 4 (17–4 PH sst) 4 (440C sst) 4 (not used)

5 (PVDF) – 5 (TPE) 5 (TPE) 5 (TPE)

– 6 (not used) 6 (Santoprene ) 6 (Santoprene )

– 9 (polypropylene) 9 (not used) 9 (not used)

– A (PVDF) A (not used) A (not used)

– G (not used) G (Geolast ) G (Geolast )

246450 Stainless Steel Air Motor Conversion Kit Use kit 246450 and refer to instruction manual 309643 (included with kit) to convert from aluminum air motor to stainless steel air motor.

24 308443

Page 25 of the Graco DS2 user manual — Repair Kit Matrix
Page 25 · click to enlarge
Page 25

Repair Kit Matrix

For Husky 1040 Acetal, Polypropylene, and PVDF Pumps, Series A Repair Kits may be ordered separately. To repair the air valve, order Part No. 236273 for aluminum center housing models and Part 255061 for stainless steel center housing models (see page 26). Parts included in the Air Valve Repair Kit are marked with a symbol in the parts list, for example (3).

To repair your pump, select the six digits which describe your pump from the following matrix, working from left to right. The first digit is always D, the second digit is always 0 (zero), and the third is always 7. The remaining three digits define the materials of construction. Parts included in the kit are marked with an asterisk in the parts list, for example (201*). For example, if your pump has polypropylene seats, PTFE balls, and PTFE diaphragms, order Repair Kit D 0 7 9 1 1. If you only need to repair certain parts (for example, the diaphragms), use the 0 (null) digits for the seats and balls, and order Repair Kit D 0 7 0 0 1. The digits in the matrix do not correspond to the ref. nos. in the parts drawing and lists on pages 26 to 27.

Graco DS2 — Repair Kit Matrix diagram (page 25)
Fig. 4 · Repair Kit Matrix

D (for all pumps) 0 (for all pumps) 7 (Plastic) – 0 (null) 0 (null) 0 (null)

– 3 (316 sst) 3 (316 sst) 3 (not used)

– 4 (17–4 PH sst) 4 (440C sst) 4 (not used)

– 6 (Santoprene ) 6 (Santoprene ) 6 (Santoprene )

– 9 (polypropylene) 9 (not used) 9 (not used)

– A (PVDF) A (not used) A (not used)

– G (Geolast ) G (Geolast ) G (Geolast )

308443 25

Page 26 of the Graco DS2 user manual — Parts
Page 26 · click to enlarge
Page 26

Parts

Graco DS2 — Parts diagram (page 26)
Fig. 5 · Parts

* These parts are included in the Pump Repair Kit, which may be purchased separately.

Refer to the Repair Kit Matrix on page 25 to determine the correct kit for your pump.

These parts are included in Air Valve Repair Kit 236273 (aluminum center housing mod- els), which may be purchased separately.

These parts are included in Air Valve Repair Kit 255061 (stainless steel center housing models) which may be purchased separately.

Replacement Danger and Warning labels, tags and cards are available at no cost.

These parts are unique to remote piloted air motor, D8 and DS

26 308443

Page 27 of the Graco DS2 user manual — Air Motor Parts List (Matrix Column 2)
Page 27 · click to enlarge
Page 27

Parts

Air Motor Parts List (Matrix Column 2)

Air Motor Parts List (Matrix Column 2)

Graco DS2 — Air Motor Parts List (Matrix Column 2) diagram (page 27)
Fig. 6 · Air Motor Parts List (Matrix Column 2)
Graco DS2 — Air Motor Parts List (Matrix Column 2) diagram (page 27)
Fig. 7 · Air Motor Parts List (Matrix Column 2)

3 116344 SCREW, mach, hex flange hd; M5 x 0.8; 12 mm (0.47 in.)

25 115643 SCREW; M8 x 1.25; 25 mm (1 in.) 12

308443 27

Page 28 of the Graco DS2 user manual — Fluid Section Parts List (Matrix Column 3)
Page 28 · click to enlarge
Page 28

Parts

Fluid Section Parts List (Matrix Column 3)

Fluid Section Parts List (Matrix Column 3)

Graco DS2 — Fluid Section Parts List (Matrix Column 3) diagram (page 28)
Fig. 8 · Fluid Section Parts List (Matrix Column 3)
Graco DS2 — Fluid Section Parts List (Matrix Column 3) diagram (page 28)
Fig. 9 · Fluid Section Parts List (Matrix Column 3)

106 112560 SCREW; M8 x 1.25; 70 mm (2.76 in.); sst 12

106 112560 SCREW; M8 x 1.25; 70 mm (2.76 in.); sst 12

112 112559 SCREW; M8 x 1.25; 40 mm (1.57 in.); sst 12

112 112559 SCREW; M8 x 1.25; 40 mm (1.57 in.); sst 12

106 112560 SCREW; M8 x 1.25; 70 mm (2.76 in.); sst 12

112 112559 SCREW; M8 x 1.25; 40 mm (1.57 in.); sst 12

28 308443

Page 29 of the Graco DS2 user manual — Ball Parts List (Matrix Column 5)
Page 29 · click to enlarge
Page 29

Parts

Seat Parts List (Matrix Column 4)

Diaphragm Parts List (Matrix Column 6)

Graco DS2 — Seat Parts List (Matrix Column 4) diagram (page 29)
Fig. 10 · Seat Parts List (Matrix Column 4)
Graco DS2 — Seat Parts List (Matrix Column 4) diagram (page 29)
Fig. 11 · Seat Parts List (Matrix Column 4)

* These parts are included in the pump repair kit, purchased separately. See Repair Kit Matrix on page 25 to determine the correct kit for your pump.

Ball Parts List (Matrix Column 5)

Graco DS2 — Ball Parts List (Matrix Column 5) diagram (page 29)
Fig. 12 · Ball Parts List (Matrix Column 5)

308443 29

Page 30 of the Graco DS2 user manual — Torque Sequence
Page 30 · click to enlarge
Page 30

Torque Sequence

Always follow torque sequence when instructed to torque fasteners.

1. Left/Right Fluid Covers Torque bolts to 130–150 in–lb (14–17 N m)
3. Outlet Manifold Torque bolts to 80–90 in–lb (9–10 N m)
2. Inlet Manifold Torque bolts to 80–90 in–lb (9–10 N m)

30 308443

Page 31 of the Graco DS2 user manual — Dimensional Drawings
Page 31 · click to enlarge
Page 31

Dimensional Drawings

Graco DS2 — Dimensional Drawings diagram (page 31)
Fig. 13 · Dimensional Drawings

(ANSI Flange) Fluid Outlet

Port Diameter1.15 in. (29 mm)

Eight 0.62 in. (16 mm) slots

Four 0.5 in. (12.5 mm) diameter holes 5.0 in. (127 mm)

(ANSI Flange) Fluid Inlet

308443 31

Page 32 of the Graco DS2 user manual — Technical Data
Page 32 · click to enlarge
Page 32

Technical Data

Maximum fluid working pressure 120 psi

Wetted parts Vary by Model. See pages 27 and 29 Non-wetted external parts aluminum, 302, 316 stainless steel

(0.8 MPa, 8 bar) Air pressure operating range 20 to 120 psi

polyester (labels) Weight (approximate) Polypropylene Models with aluminum center section: 19 lb (8.6 kg)

(0.14 to 0.8 MPa, 1.4 to 8 bar) Maximum air consumption 60 scfm Air consumption at 70 psi/20 gpm 20 scfm (see chart) Maximum free-flow delivery 42 gpm (159 l/min) Maximum pump speed 276 cpm Gallons (Liters) per cycle 0.15 (0.57) Maximum suction lift 18 ft (5.48 m) wet or dry Maximum Size pumpable solids 1/8 in. (3.2 mm) * Maximum noise level at 100 psi, 50 cpm 89 dBa Sound power level 100 dBa * Noise level at 70 psi, 50 cycles/min: 78 dBa Maximum operating temperature 150F (65.5C) Air inlet size 1/2 npt(f) Fluid inlet size. 1” Raised Face Flange Fluid outlet size. 1” Raised Face Flange

with stainless steel center section : 32 lb (14.6 kg)

Acetal Models

with aluminum center section : 22 lb (10 kg)

PVDF Models

with aluminum center section: 25 lb (11.3 kg)

with stainless steel center section: 35 lb (16 kg)

Geolast and Santoprene are registered trademarks of the Monsanto Co.

Loctite is a registered trademark of the Loctite Corporation. * Noise levels measured with the pump mounted on the floor, using Rubber Foot Kit 236452. Sound power measured per ISO Standard 9216.

32 308443

Page 33 of the Graco DS2 user manual — D
Page 33 · click to enlarge
Page 33

Performance Chart

Test Conditions: Pump tested in water with inlet submerged.

FLUID OUTLET PRESSURE––psi (MPa, bar)

(0.84, 8.4)

A

A at 120 psi (0.7 MPa, 7 bar) air pressure

B at 100 psi (0.7 MPa, 7 bar) air pressure C at 70 psi (0.48 MPa, 4.8 bar) air pressure

(0.7, 7)

D at 40 psi (0.28 MPa, 2.8 bar) air pressure

(0.55, 5.5)

To find Fluid Outlet Pressure (psi/MPa/bar) at a specific fluid flow (gpm/lpm) and operating air pressure (psi/MPa/bar):

(0.41, 4.1)

1. Locate fluid flow rate along bottom of chart.

D

(0.28, 2.8)

2. Follow vertical line up to intersection with selected fluid outlet pressure curve.

(0.14, 1.4)

3. Follow left to scale to read fluid outlet pressure.

0 5 10 15 20 25 30 35 40

(38) (133) (152) (76) (114) (95) (57) (19)

AIR CONSUMPTION––scfm (cubic meters/min)

(1.68)

A at 120 psi (0.7 MPa, 7 bar) air pressure

B at 100 psi (0.7 MPa, 7 bar) air pressure C at 70 psi (0.48 MPa, 4.8 bar) air pressure

(1.40)

D at 40 psi (0.28 MPa, 2.8 bar) air pressure

A

(1.12)

To find Pump Air Consumption (scfm or m /min) at a specific fluid flow (gpm/lpm) and air pressure (psi/MPa/bar):

(0.84)

1. Locate fluid flow rate along bottom of chart.

(0.56)

2. Read vertical line up to intersection with selected air consumption curve.

D

3. Follow left to scale to read air consumption.

(0.28)

0 5 10 15 20 25 30 35 40

Show 8 more labels / short text on this page
Fluid Pressure Curves · FLUID FLOW--gpm (lpm) · Air Consumption Curves · (95) (57) (19) · (38) (133) · (152) (76) (114) · FLUID FLOW--gpm (lpm) · 308443 33
Page 34 of the Graco DS2 user manual — Graco Information
Page 34 · click to enlarge
Page 34

Graco Warranties

Graco Standard Husky Pump Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of five years from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within six years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Extended Product Warranty Graco warrants all Husky 205, 307, 515, 716, 1040, 1590, 2150, and 3275 air valve center sections to be free from defects in material and workmanship for a period of fifteen years from date installed in service by the original purchaser. Normal wear of items such as packings or seals are not considered to be defects in material and workmanship.

Five years Graco will provide parts and labor. Six to Fifteen years Graco will replace defective parts only.

Graco Information

TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

1–800–328–0211 Toll Free 612–623–6921 612–378–3505 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

This manual contains English. MM 308443

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

www.graco.com 308443 10/1994, Revised 08/2007

34 308443

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump cycles at stall or fails to hold pressure at stall.Worn check valve balls (301), seats (201) or o-rings (202).Replace. See page 18. p.14
Pump will not cycle, or cycles once and stops.Air valve is stuck or dirty.Disassemble and clean air valve. See pages 16 to 17. Use filtered air. p.14
Pump will not cycle, or cycles once and stops.Check valve ball (301) severely worn and wedged in seat (201) or manifold (102 or 103).Replace ball and seat. See page 18. p.14
Pump will not cycle, or cycles once and stops.Check valve ball (301) is wedged into seat (201), due to overpressur- ization.Install Pressure Relief Valve (see page 9). p.14
Pump will not cycle, or cycles once and stops.Dispensing valve clogged.Relieve pressure and clear valve. p.14
Pump operates erratically.Clogged suction line.Inspect; clear. p.14
Pump operates erratically.Sticky or leaking balls (301).Clean or replace. See page 18. p.14
Pump operates erratically.Diaphragm ruptured.Replace. See pages 19 to 21. p.14
Pump operates erratically.Restricted exhaust.Remove restriction. p.14
Air bubbles in fluid.Suction line is loose.Tighten. p.14
Air bubbles in fluid.Diaphragm ruptured.Replace. See pages 19 to 21. p.14
Air bubbles in fluid.Loose inlet manifold (102), dam- aged seal between manifold and seat (201), damaged o-rings (202).Tighten manifold bolts (106 or 112) or replace seats (201) or o-rings (202). See page 18. p.14
Air bubbles in fluid.Loose fluid side plate (105).Tighten or replace (pages 19 to 21). p.14
Air bubbles in fluid.Damaged o-ring (108).Replace. See pages 19 to 21. p.14
Fluid in exhaust air.Diaphragm ruptured.Replace. See pages 19 to 21. p.15
Fluid in exhaust air.Loose fluid side plate (105).Tighten or replace (pages 19 to 21). p.15
Pump exhausts excessive air at stall.Worn air valve block (7), o-ring (6), plate (8), pilot block (18), u-cups (10), or pilot pin o-rings (17).Repair or replace. See pages 16 to 17. p.15
Pump exhausts excessive air at stall.Worn shaft seals (402).Replace. See pages 19 to 21. p.15
Pump leaks air externally.Air valve cover (2) or air valve cover screws (3) are loose.Tighten screws. See page 17. p.15
Pump leaks air externally.Air valve gasket (4) or air cover gasket (22) is damaged.Inspect; replace. See pages 16 to 17 and 22 to 23. p.15
Pump leaks air externally.Air cover screws (25) are loose.Tighten screws. See pages 22 to 23. p.15
Pump leaks fluid externally from ball check valves.Loose manifolds (102, 103), dam- aged seal between manifold and seat (201), damaged o-rings (202).Tighten manifold bolts (106 or 112) or replace seats (201) or o-rings (202). See page 18. p.15

Ask about the Graco DS2

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco DS2

Be the first to ask — other owners or our team will answer.

Original document

Graco DS2 manual PDF

34 pages·686 KB·Stroller·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…